Item Description
Emergency Shutdown Press the Emergency Shutdown switch to power down the testhead
Switch and its associated equipment in an emergency situation.
It turns off all AC power to the testhead, and is equivalent to turning off
the main circuit breaker on the rear of the system.
Main Power Switch Controls the incoming line voltage and is located at the rear of the
system.
Testhead Rotation Rotates the testhead into any position from 0 to 90 degrees from the
Switch horizontal.
Guided probe Used by the operator for manual probing of circuits.
Operator footswitch Functions like the START button in the operator screen; can be used
when the operator’s hands are busy.
2 Getting Started
Board Test Methods
The following are some of the test methods used by i3070 In-Circuit Test Systems.
Some of these test methods may not be available on your system, but can be
included as an option.
Getting Started 3
i3070 In-Circuit Test Software
The i3070 In-Circuit Test Software provides the tools for test programming and
deployment, with an operator interface for production testing. The applications and
programming software include languages for board test development and quality
reporting.
To maximize productivity, the test development software can also be set up and run
from the developers’ own Windows workstations in addition to the testhead.
Table 3 lists the standard software provided for test development, which depends
on your i3070 system platform (Mux or UnMux). Table 4 lists other board test
applications and options. Refer to Overview of Test Development Process, which
describes the process and explains when and how the various tools are used.
4 Getting Started
Table 4 Other board test applications
Application Description
Access Consul tant An analysis and advisory tool that allows you to optimize the use of test probes in limited
access situations.
Coverage Analyst Provides a comprehensive view of the predictive test coverage based on the contents of a
board test directory.
Pushbutton QSTATS Produces several SQC reports that help you analyze your production process and identify
process problems.
Korn Shell Shell environment for executing UNIX commands on Windows operating systems.
BT-Basic Programming environment for editing and manipulating test programs.
Diagnostics (DGN) Troubleshooting tool that lets you check the hardware configuration, verify performance, and
isolate failures to a field-replaceable unit (FRU).
Boundary Scan For testing digital devices that comply with IEEE Standard 1149.1.
Data Log Converter Optional tool that runs in the background to generate reports from i3070 log files, and sends
the customized output to a specified folder or web server.
Getting Started 5
Starting the i3070 Series 6 System
6 Getting Started
Shutting Down
Shut down the system before removing power to perform tasks such as installing a
new disk or interface card.
Unboot the testhead before shutting down the controller to
prevent damage to the software.
Getting Started 7
Emergency Shutdown
The Emergency Shutdown Switch, (or Emergency Off, EMO) is the red button
located at the lower left corner on the front of the testhead. It turns off all AC and
DC power to the testhead, and is equivalent to turning off the PDU on the rear of
the pod.
Press the Emergency Shutdown Switch if you ever need to power down the
testhead and its associated equipment in an emergency situation.
8 Getting Started