Appendix A Residential Design Standards
Appendix A Residential Design Standards
October 2011
Contents
1. Introduction 4
1.1 Role and purpose of this Supplementary Planning Document 4
1.2 Related planning documents 5
1.3 Key considerations 6
FIGURES
Figure 1 – Family homes zones 11
TABLES
Table 1 – Residential density standards 8
Table 2 – Minimum dwelling size standards 13
Table 3 – Minimum room sizes 14
2
Residential design standards October 2011
APPENDICES
1 Wheelchair design standards 42
2 Calculating density 43
3 Further information 46
3
1. Introduction
This document provides detailed guidance to the Core Strategy and saved policies of the Southwark Plan. This
SPD is not creating policy. This SPD updates to 2008 Residential Design Standards SPD to take into account
recent changes to housing policy introduced through the Core Strategy. We may need to do further changes
to this SPD as we continue to update our housing policies through area action plans and other planning
documents so please make sure that you check on the website to find out whether any new guidance has
taken the place of this document at www.southwark.gov.uk/ldf
The SPD will be a material consideration and will have significant weight in the determination of a planning
application. The SPD principally provides further information on the following Core Strategy and saved
Southwark Plan polices
• Strategic Policy 5 – Providing new homes
• Strategic Policy 7 – Family homes
• Strategic Policy 8 – Student homes
• Strategic Policy 12 – Design and conservation
• Saved Southwark Plan Policy 3.2 – Protection of Amenity
• Saved Southwark Plan Policy 3.11 – Efficient Use of Land
• Saved Southwark Plan Policy 3.12 – Quality in Design
• Saved Southwark Plan Policy 3.14 – Designing out Crime
• Saved Southwark Plan Policy 4.2 – Quality of Residential Development
• Saved Southwark Plan Policy 4.3 – Mix of Dwellings
• Saved Southwark Plan Policy 4.5 – Wheelchair Affordable Housing
• Saved Southwark Plan Policy 4.7 – Non Self-Contained Housing for Identified User Groups
4
Residential design standards October 2011
The SPD applies to new residential development, conversions of existing dwellings and extensions or alterations
to existing homes and covers the following
• General principles applying to all development
• Standards specific to certain types of residential development in addition to the general principles
• Guidelines for housing meeting specific needs.
Where applicants cannot achieve the appropriate standard, they must justify this and demonstrate why not
and show the measures taken to compensate for this. This would normally be done through the Design and
Access Statement.
5
1.3 Key considerations
This section covers some of the key considerations that applicants will have to consider when designing
proposals for general needs residential development with regard to strategic policies 5 and 7 of the Core
Strategy and saved policies 4.2 and 4.3 of the Southwark Plan. Applicants should also refer to other policies
and guidance in the development plan and the local development framework, including area action plans and
the London Plan, this SPD and other SPDs that are relevant to their development. Housing for specific user
groups is covered in section 4 of this SPD. We suggest you engage with our development management team
at an early stage to ensure the application complies with our policies and provides a high quality of design.
For major residential development (those over 10 units) does the development?
• Have at least 60% of units suitable for three or more occupants containing two or more bedrooms)?
• Include studio flats? If so are these limited to 5% of the total number of dwellings? Note that studio
flats are not considered suitable for affordable housing provision.
• Include a minimum of 10% of units that are suitable for wheelchair users in line with guidance set out
in section 2.10 of this SPD?
• Provide the minimum amount of family homes with direct access to private outdoor space as set out
in sections 2.3, 2.6, 3.1, 3.2 and 3.4?
6
Residential design standards October 2011
Where an application for planning permission will increase the total amount of development on a site to more
than 10 dwellings, the development will be considered as a major development and the standards within this
SPD and the Core Strategy and saved policies of the Southwark Plan relating to major developments will apply.
This will be the case for
• Sites that are artificially sub-divided. In these circumstances the proposals will be judged as to whether
or not a development makes the best use of land through the efficient use of land policy and by applying
appropriate density levels based on the context and character of the surrounding development and
public transport accessibility levels
• Phased development. In these circumstances where the development is clearly part of the first phase of a
larger development which is over 10 units, it will be considered as a major application and the residential
design standards for major developments will be applied. Where a phased development with planning
permission is subsequently amended and the total units are increased, the council will also apply the
residential design standards for major developments
• Additional units added through supplementary planning applications or a subsequent application on an
adjoining site or through a mixed use scheme. In these circumstances where there is an extant planning
permission and a fresh planning permission is submitted for a revised scheme taking the total units
above 10 units, the residential design standards for major applications will be applied.
The council will seek to ensure that proposals deliberately designed to circumvent the threshold of 10 units
will not be accepted.
It is important that the appropriate amount of residential development occurs in appropriate places. Making
efficient use of land to provide new homes, jobs and services, without building on open space, is important.
The right level of density ensures efficient use of land without negative impacts on the environment. New
residential development must take into account the local character and context of the area so that it fits in
with its surroundings and does not have a negative impact on amenity and traffic. High quality landscaping
can help to mix a range of densities together.
7
Strategic Policy 5 of the Core Strategy sets out density ranges for different zones in Southwark. The detailed
boundaries of the zones are shown on the proposals map. The density ranges are guides to the efficient use of
land in different areas based on the general character of the area and its accessibility to public transport. The
density ranges are set out in table 1. The Central Activities Zone and Urban Zone tend to be characterised by
flats, maisonettes and terraced housing. The Suburban Zones generally contains a more open character, with
larger gardens and houses rather than flats. Section 3 of this SPD contains further guidance specific to these
types of residential development.
Suburban Zone (North, Middle and South) 200 to 350 habitable rooms per hectare
Strategic Policy 5 states within the opportunity areas and action area cores the maximum densities may be
exceeded when developments are of an exemplary standard of design. For the development to be considered
as being of an exemplary standard of design applicants will be expected to demonstrate that their proposed
schemes exceed the residential design standards set out in this SPD, specifically they will be expected to
• Significantly exceed minimum floorspace standards
• Provide for bulk storage
• Include a predominance of dual aspect units in the development
• Exceed the minimum ceiling height of 2.3 metres required by the Building Regulations
• Have natural light and ventilation in kitchens and bathrooms
• Exceed amenity space standards
• Meet good sunlight and daylight standards
• Have excellent accessibility within dwellings including meeting Lifetime Homes standards
• Minimise corridor lengths by having an increased number of cores
• Minimise noise nuisance in flat developments by stacking floors so that bedrooms are above bedrooms,
lounges are above lounges etc
• Obtain Secured by Design certification
• Have exceptional environmental performance that exceeds the standards set out in the Sustainable
Design and Construction Supplementary Planning Document. This will include designing an energy
efficient development, using long lasting building materials and reducing water consumption. See the
Sustainable Design and Construction Supplementary Planning Document for further guidance.
8
Residential design standards October 2011
• Maximise the potential of the site as demonstrated in the applicant’s Design and Access Statement.
See the Design and Access Statements Supplementary Planning Document for further guidance.
• Make a positive contribution to local context, character and communities, including contributing to the
streetscape.
Strategic Policy 7 of the Core Strategy sets out dwelling mix requirements for schemes of 10 or more units.
We also set out area specific requirements in the area action plans. These requirements are set out below
with guidance on the household sizes needing to be accommodated. The level of family housing we require
is based on the density of development and the ability of development to provide amenity space for families.
Major new and converted housing developments (developments of over 10 units) will need to cater for these
needs by providing a mix of self-contained dwelling types and sizes for different household sizes, as follows
• a minimum of 60% of dwellings suitable for three or more occupants (containing two or more bedrooms)
• a maximum of 5% of dwellings as studio flats
• minimum amount of dwellings suitable for at least five occupants (with a mix of 3, 4 or 5 bedrooms)
with directly accessible amenity space in line with the following:
- a minimum of 10% in Potters Field, London Bridge, Elephant and Castle opportunity area and
the north of Blackfriars Road
- a minimum of 20% in the urban density zone and the Central Activities Zone, except where
set out above
- a minimum of 30% of dwellings in the suburban density zone
• Other than studio flats which must be private, homes of all sizes should provide a mix of private, social
and intermediate housing.
9
Area action plan policies set out housing mix requirements for specific
areas. These are
• Aylesbury Action Area Core
- A maximum of 3% studios all in private tenure;
- at least 70% of dwellings to have two or more bedrooms;
- at least 20% of dwellings have three bedrooms;
- at least 7% of dwellings have four bedrooms; and
- at least 3% of dwellings have five or more bedrooms
• Canada Water Action Area Core
- a minimum of 20% of dwellings to have 3, 4 or 5
bedrooms (suitable for at least five occupants)
in the Canada Water action area core
• Peckham and Nunhead Action Area Core:
- We will consider whether we will vary the level of family
housing through the preferred options
consultation. In the meantime we will apply the
requirements for the urban and suburban
density zones, set out above.
10
Residential design standards October 2011
11
2.4 Minimum floor and room areas for different
sized dwellings
Strategic Policy 7 of the Core Strategy highlights the importance of
ensuring that all new development is of a high quality with good living
conditions. Minimum floor area standards ensure an adequate amount
of space is provided in residential development to achieve a pleasant and
healthy living environment. This is also a priority for the Mayor, who,
through the London Plan and London Housing Design Guide, requires
minimum space standards in order to make new homes provide good
living conditions for different sized households.
Table 2 sets out the minimum overall dwelling sizes we expect all
development to meet. These are minimum standards which developers
are encouraged to exceed. They are in line with the requirements of the
London Plan and are based on the number of people expected to live in
a home. This means developers should state the number of occupiers a
home is designed to accommodate. Across a scheme, the mix of dwelling
types should cater for the full range of household sizes. We will assess this
using the average dwelling sizes set out in Table 2. These are minimum
floor areas and applicants should seek to provide larger floor areas in
developments where possible.
12
Residential design standards October 2011
For the purposes of affordable housing calculations, habitable rooms exceeding 27.5 sqm will be counted as
two rooms. See the Affordable Housing Supplementary Planning Document for further information.
Table 3 sets out the minimum room areas for individual rooms. These must be met in addition to the minimum
dwelling sizes set out in Table 2. It is recommended that rooms are separated within a unit where possible,
particularly for social housing where there are frequently more people living in the dwelling. A larger room
size is required for open plan units to allow some separation within the room (especially between cooking and
living) and to allow more space as everyone in the dwelling will be using that same one room.
13
Table 3: Minimum room areas in sqm
Single bedroom 7 7 7
For studio flats there needs to be sufficient separation between the cooking and sleeping areas.
See section 3.5 of this SPD for further information on the larger room sizes required for social rented affordable
housing.
All residential development needs to provide storage space to meet the likely needs and requirements of
potential occupiers. Table 3 sets out the minimum requirements for storage for each sized dwelling. Applicants
must ensure that there is storage space for the following:
• Refuse storage. Internal space for storage of waste should be provided within kitchens (in cupboards)
or close to kitchens in utility rooms or connected garages. This should have a minimum capacity of 30
litres and be able to store at least three bins for different types of waste. No bin should be smaller than
seven litres
• General household items such as vacuum cleaners in all dwellings and buggies in dwellings with two or
more bedrooms
• Food and kitchen storage, including space for electrical machines
• Storage for tools etc for household, garden or vehicle/bicycle maintenance, especially where no garage
is provided
In larger developments basements can provide additional capacity for storage and this should be considered.
14
Residential design standards October 2011
Building Regulations require a minimum headroom of 2.3 metres. Exceptions may be considered in circumstances
where the proposal is to convert an existing building into a flat, providing all the other appropriate residential
design standards in this SPD are met.
Habitable rooms in attics should have a minimum room height of 2.3 metres over at least half of the habitable
floor area. Any floor area where the ceiling height is less than 1.5 metres will not count towards the habitable
floorspace.
15
2.6 Outdoor Amenity Space
All new residential development must provide an adequate amount of useable outdoor amenity space. The
nature and scale of the amenity space should be appropriate to the location of the development, its function
and the character of the area within which it is situated. For example development designed for families will
need to include private gardens and play areas whereas for 1 bed flats, balconies and more generic communal
areas may be more appropriate.
In most developments there should be a mixture of both private and communal amenity space. Private amenity
space is space specific for one dwelling and can be accessed only by the people living within that dwelling. It is
particularly important for family housing in order to provide a safe outdoor area for children to play in. It can
take the form of private gardens, balconies, terraces and roof gardens. Juliet balconies are not considered as
amenity space as they do not add useable space to the development. Access to private amenity space should
not be from the bedroom.
Communal amenity space is shared space for use by everyone within the development. It can take the form
of a communal garden or roof garden. All residents should have access to communal amenity space where it
is provided.
Section 3 sets out the specific outdoor amenity space requirements for different types of residential development.
These standards are in addition to the general standards set out in this section.
Where it is not possible to provide an adequate amount of outdoor amenity space in accordance with
section 3 of this SPD and the saved Southwark Plan policy 4.2, the applicant must justify why this cannot be
achieved through the Design and Access Statement. Where developments are within immediate proximity of
a substantial area of public open space, accessibility to the open space, combined with better outlook, may
justify less amenity space as part of the development. In these circumstances a planning contribution may
be required instead to provide off-site public amenity space (see the Section 106 Supplementary Planning
Document).
Planning applications should show the areas allocated to future residents for outdoor amenity space. Details
of access to and boundary treatments must also be provided with the planning application. It is important to
indicate the extent of private ownership (such as by walls, fences, railings, gates, signage, paving) to define
the boundary between public and private space.
16
Residential design standards October 2011
The elements of amenity space to be included in the amenity space calculation will depend upon the design
and layout of the proposed development. Any exception to the above will need to be justified in the Design
and Access Statement.
Maximising sunlight and daylight also helps to make a building energy efficient by reducing the need for electric
light and meeting some of the heating requirements through solar gain. The orientation of buildings can
maximise passive solar gain to keep buildings warm in winter and cool in summer. See the Design and Access
Statements Supplementary Planning Document and the Sustainable Design and Construction Supplementary
Planning Document for further information.
Developments should meet site layout requirements set out in the Building Research Establishment (BRE) Site
Layout for Daylight and Sunlight – A Guide to Good Practice (1991). In particular the following minimum tests
need to be applied to avoid the unacceptable loss of daylight and/or sunlight resulting from a development,
including new build, extensions and conversions.
Daylight and sunlight tests on the impact of the new development on neighbouring properties
Daylight tests
This test should be used where the proposed development faces the affected window of the neighbouring
property
1. Draw a line at 25 degrees upwards from the centre of the affected window;
2. If the proposed development is higher than this 25 degree line, there may be an unacceptable loss of
daylight to the affected window.
17
This test should be used where the proposed development is at right
angles to the affected window of the neighbouring property
1. Draw a line at 45 degrees upwards from the centre of the affected
window;
2. Draw a line at 45 degrees sideways from the centre of the affected
window.
If the proposed development is both higher and wider than these 45
degree lines, there may be an unacceptable loss of daylight to the affected
window.
Sunlight tests
This test should be used where any part of the proposed development
lies to the south of the affected window of the neighbouring property,
between due east and due west
1. Draw a line at 25 degrees upwards from a point two metres above
ground level.
2. If the proposed development is higher than this 25 degree line,
there may be an unacceptable loss of sunlight to the affected
window.
If the street or garden outside is higher than this 30 degree line then there
is unlikely to be adequate natural daylight to the room and it is unlikely
to be acceptable.
18
Residential design standards October 2011
If the proposed development fails any of these tests, further investigation and evidence may be required in
order to assess whether an unacceptable loss of daylight and/or sunlight will occur. The evidence should be
prepared by a suitably qualified professional and must be in accordance with the BRE guidance. The cost of
any further investigation and evidence must be met by the applicant.
Additional tests
In addition to the BRE tests, to ensure that natural light and ventilation are maximised, all residential
developments should meet the following requirements
• At least one main wall with a window should face within 90 degrees of due south
• North facing gardens should be avoided
• Garages should be situated to the north of houses to maximise daylight and sunlight to the rest of the
dwelling
• Taller buildings should be sited to the north of the development, with low rise at the south to maximise
daylight and sunlight penetration to the development
• Where possible, living rooms should face the southern or western parts of the sky and kitchens towards
the north east
• In order to make the most of solar gain through passive solar energy the main solar collecting glazing
should face within 30 degrees of due south
• The council encourages dwellings to be dual aspect in terms of having multiple windows looking in more
than one direction. This allows more light into the dwelling and allows cross ventilation. Where dual
aspect cannot be provided for example in flat developments due to problems of overlooking neighbours,
the applicant must prove that the single aspect is of a standard not inferior to multiple aspects and that
a high quality of design is still achieved (through the Design and Access Statement). The Sustainable
Design and Construction SPD provides further guidance on locating windows away from busy roads and
railways to minimise noise and pollution to the development
• New development should not cause excessive overshadowing of existing communal amenity spaces or
neighbouring properties
• No new development should result in the complete loss of sunlight to an existing adjoining property.
19
To prevent unnecessary problems of overlooking, loss of privacy and
disturbance, development should achieve the following distances
• A minimum distance of 12 metres at the front of the building and
any elevation that fronts onto a highway
• A minimum distance of 21 metres at the rear of the building.
Where these minimum distances cannot be met, applicants must provide
justification through the Design and Access Statement.
20
Residential design standards October 2011
1 Car Parking Where car parking is adjacent to The general parking space width of
the home, it should be capable 2400mm must have a grass verge or path
of enlargement to attain 3.3m 900mm wide running beside to enable the
width. hard landscaping to have an overall width
of 3300mm at a later date.
2 Access from Car The distance from the car A level approach is preferable. Where
Parking parking space to the home topography prevents this, a maximum
should be kept to a minimum gradient on an individual slope is
and should be level or gently permissible as follows
sloping. • 1:12 if the slope is less than 5m;
• 1:15 if it is between 5m – 10m;
• 1:20 where the slope is more than 10m.
3 Approach The approach to all entrances The specification for Criterion 2 gives the
should be level or gently sloping. definition of gently sloping.
4 External Entrances All entrances should be The threshold upstand should not exceed
illuminated, have level access 15mm.
over the threshold and have a
covered main entrance.
Lifts
Clear landing entrances minimum 1500mm
x 1500mm
Minimum internal dimensions 1100mm x
1400mm
Controls between 900 – 1200mm from
floor and 400mm from the lift’s internal
front wall.
21
Lifetime Home Requirement Stated specifications and
feature dimensions to conform
6 Doorways & Hallways The width of internal doorways Front door
and hallways should conform Clear opening width of 800mm, with a
to Part M, except that when the 300 nib to the side of the leading edge.
approach is not head on and the
hallway width is 900mm, the Internal + Back doors
clear opening width should be Clear opening width of 750mm / corridor
900mm rather than 800mm. or passageway width 900mm if the
There should be 300mm nib approach is head-on or 1200mm when the
or wall space to the side of the approach in not head-on, clear opening
leading edge of the doors on width 775mm / corridor 1050mm when
entrance level. the approach is not head on, 900mm /
900mm corridor when the approach is not
head on.
7 Wheelchair Accessibility There should be space for A turning circle of 1500mm or a turning
turning a wheelchair in dining ellipse of 1700mm x 1400mm is required
areas and living rooms and in living rooms and dining areas.
adequate circulation space for
wheelchairs elsewhere.
8 Living Room The living room should be at Living room at entrance level.
entrance level.
9 Two or more storey In houses of two or more A space on the entrance level that could
requirements storeys, there should be space on conveniently be used as a bed-space.
the entrance level that could be
used as a convenient bed space.
10 WC In houses with three bedrooms The drainage for the future shower should
or more there should be a be provided in all dwellings.
wheelchair accessible toilet at For dwellings with 3 or more bedrooms
entrance level with drainage or on one level, the WC must be fully
provision enabling a shower accessible. A wheelchair user should be
to be fitted in the future. In able to close the door from within and
houses with two bedrooms the achieve side transfer from a wheelchair
downstairs toilet should conform to one side of the WC. There must be
at least to Part M. 1100mm clear space to the front of the
bowl. The shower provision must be within
the closet or adjacent to the WC.
22
Residential design standards October 2011
12 Lift Capability The design should incorporate There must be a minimum of 900mm
provision for a future stair lift clear distance between the stair wall (on
and a suitably identified space which the stair lift would normally be fixed)
for a through the floor lift from and the edge of the opposite handrail/
the ground floor to the first balustrade.
floor, for example to a bedroom
next to the bathroom. Unobstructed ‘landings’ are needed at the
top and bottom of the stairs
13 Main Bedroom The design and specification Technological advances in hoist design
should provide a reasonable mean that a straight run is no longer
route for a potential hoist from a required.
main bedroom to the bathroom.
14 Bathroom Layout The bathroom should be Although there is not a requirement for a
designed for ease of access to turning circle in bathrooms, sufficient space
the bath, WC & wash basin. should be provided so that a wheelchair
user can conveniently use the bathroom
and gain side access to the WC.
15 Window Specification Living room window glazing People should be able to see out of the
should begin no higher than window whilst seated. Wheelchair users
800mm from the floor level should be able to operate at least one
and windows should be easy to window in each room.
open/operate.
16 Fixtures & Fittings Switches, sockets, ventilation This applies to all rooms, including the
and service controls should be kitchen and bathroom
at a height usable by all (i.e.
between 450 and 1200mm from
the floor).
23
2.10 Wheelchair housing
Lifetime Homes are suitable for many older people and the vast majority of disabled people but they are not
designed to meet the additional spatial requirements for wheelchair users. There remains a shortage of housing
suitable for wheelchair users across London and wheelchair housing has been identified as a key housing need
in Southwark. The London Plan and the saved Southwark Plan policy 4.3 require at least 10% habitable rooms
or units of major new residential development (10 units or more) to be designed to be wheelchair accessible.
The London Borough of Greenwich has developed the ‘Greenwich Standard’, known as the South East
London Housing Partnership Wheelchair Housing Design Guidelines, which is a nationally recognised best
practice standard for wheelchair housing. It incorporates and builds on the nationally recognised Habinteg
Wheelchair Housing Design Guide and the Housing Corporation’s Scheme Development Standards. This SPD
adopts the South East London Housing Partnership Wheelchair Housing Design Guidelines to be used as
Southwark’s guidelines for wheelchair design guidelines. New developments must meet this standard unless
site constraints such as topography prevent the standard from being met. Where this is the case the council
will require justification as to why the standard cannot be met. The standard covers the following 15 areas
1. Moving around outside
2. Using outdoor space
3. Approaching the home
4. Negotiating the entrance door
5. Entering and leaving, dealing with callers
6. Negotiating the secondary door
7. Moving around inside/storing things
8. Moving between levels
9. Using living spaces
10. Using the kitchen
11. Using the bathroom and shower room
12. Using bedrooms
13. Operating doors
14. Operating windows
15. Controlling services.
Appendix A of this SPD shows the link to the most up-to-date wheelchair standard
24
Residential design standards October 2011
All flat developments must meet the following minimum standards and seek to exceed these where possible
• 50 sqm communal amenity space per development
• For units containing three or more bedrooms, 10 sqm of private amenity space
• For units containing two or less bedrooms, 10 sqm of private amenity space should ideally be provided.
Where it is not possible to provide 10 sqm of private amenity space, as much space as possible should be
provided as private amenity space, with the remaining amount added towards the communal amenity
space requirement. For example, if a private balcony of 3 sqm can be provided, 7 sqm should be added
onto the communal amenity space
• Balconies, terraces and roof gardens must be a minimum of 3 sqm to count towards private amenity
space.
All amenity space must be intrinsic to the design of the development. Care must be taken so that private
amenity space such as roof terraces and balconies does not adversely affect neighbouring residents’ privacy
or sunlight. Roof gardens should be located appropriately to avoid problems of overlooking. Screens and
landscaping can be used to help overcome problems of overlooking. Wherever possible larger units should be
provided at ground level, to ensure access to private amenity space. Units designed as family units should be
provided at the ground level. This enables children to have direct access to outdoor amenity space and reduces
potential access problems of carrying children or push chairs up flights of stairs.
25
Applications with family units away from the ground floor should provide justification through the Design
and Access Statement of how families benefit from access to good quality amenity space and that families
continue to have access to private space and play areas.
In addition to the communal amenity space requirements, children’s play areas should be provided in all new
flat developments containing the potential for 10 or more child bed spaces. This is a requirement from London
Plan Policy 3.6 and the Mayor’s Supplementary Planning Guidance on Providing for Children and Young
People’s Play and Informal Recreation. This is calculated on the basis that:
A minimum of 10 sqm of play space per child bedspace should be provided within the development. Play
areas should be overlooked by nearby housing. A management and maintenance scheme of the play area
is required to be provided by the applicant establishing the management and maintenance regime for the
children’s play area.
3.3 Conversions
Permission will not be granted for the conversion of a single dwelling house of 130 sqm or less original net
internal floorspace into 2 or more dwelling units. This is to protect small family homes with gardens for which
there is a known need in the borough. Net internal floorspace excludes space that cannot be used, such as
internal walls, under stairs and chimneys as well as all shared spaces within developments such as shared
corridors, lobbies and stairwells.
26
Residential design standards October 2011
27
Design and appearance
All extensions should
• Harmonise with the scale and architectural style of the original building
• Harmonise with the character of the area, including respecting the historic pattern of the surrounding
area
• Be successfully integrated with their surroundings. The extension should read as if it were part of
the original dwelling. Where a different approach is taken, the design and composition should be
successful. It should retain or restore existing features that are important elements in the townscape or
that contribute to the architectural integrity of proportions of a building or group of buildings
• Not unacceptably affect the amenity of neighbouring properties. This includes privacy, outlook, daylight
and sunlight
• Not be of a size or scale that would visually dominate neighbouring properties
• Be subordinate to the original building. The extension should play a “supporting role” to the original
dwelling in terms of location, form and scale. Any extension should not dominate the original building
and should be set back from the principal elevations
• Not compromise any rooms in the existing house. No habitable room should become completely internal
without a window
• Use materials that match those in the original house and the surrounding areas. Windows and doors
should be of a similar pattern and align with existing windows and door openings where possible.
In some circumstances a contrasting modern design can be successful. Applicants are strongly encouraged to
discuss this with planning officers.
When adding additional floors to existing dwellings, rooms should be vertically stacked to minimise noise
disturbance between floors or flats e.g. bedroom above bedroom, lounge above lounge. Developments should
also have adequate sound-proofing.
28
Residential design standards October 2011
Rear extensions
Rear extensions are often the most practical and appropriate way to
extend a dwelling. However, if poorly designed they can have a negative
impact on the property or neighbouring properties especially in terms of
outlook, daylight and sunlight.
They should
• Generally, for most smaller terraced and semi-detached houses,
be limited to a single-storey in height and must respect existing
building heights.
• The eave level and ridge level must be no higher than the highest
part of the roof
• 3 metres is usually the maximum depth that can be added without
harm to neighbours and preventing a feeling of enclosure
• Should not exceed 3 metres in height to prevent a feeling of
enclosure
• Respect the design and windows features of the host building.
If the existing garden is already only a minimum size as set out in section
3.1 and 3.2, a rear extension will probably not be suitable for the property.
29 29
Conservatories
Conservatories are generally rear extensions and the
above guidance should be applied to these. In addition,
conservatories should be
• To rear or side of the dwelling
• A separate room from the main dwelling so that
they can be closed off
• At ground or basement level.
Side extensions
Side extensions should
• Be subsidiary to the main building
• If the side extension is proposed to be more than
single storey, the upper floor should be set back
from the side building line
• Have roofs that match those of existing buildings
in terms of roof shapes and pitches
• Avoid the infilling of gaps between properties,
where this is an important townscape feature.
Front extensions
Front extensions are rarely acceptable due to their
impact on the appearance of the building and
townscape. Applicants are strongly encouraged to
seek the advice of a planning officer if designing front
extensions.
Roof Extensions
Roof design is very important as it will determine the overall shape of an extension.
30
Residential design standards October 2011
31
• Dormer window extensions should not dominate the rear elevation of the property. They should be
designed to sit well within the original roof slope remaining around the whole dormer. As a minimum
they should be set up 0.5 metres from the gutterline and set 0.5 metres down from the ridge
• Dormer windows should not normally be wider than they are high nor should they occupy more than
20% of the area of the roof.
We encourage the installation of green and brown roofs and walls. Green and brown roofs and walls are
‘living’ roofs and walls that can benefit the environment by enhancing biodiversity and reducing flood risks
whilst providing a high standard of insulation. See the Sustainable Design and Construction SPD for further
information on green roofs.
Applications for extensions to listed buildings or within conservation areas are also required to submit a Design
and Access Statement. See the Design and Access Statements SPD for more information on what needs to
be included in a design and access statement.Some properties within the borough are covered by an Article
4 direction, made under the Town and Country Planning General Development Order 1988 (as amended)
in order to control development where the character of an area of acknowledged importance would be
threatened. Article 4 direction removes permitted development rights to undertake certain works without
planning permission.
Within Conservation Areas development should preserve or enhance the character or appearance of the area.
Proposed development on listed buildings should preserve the building and its features of special architectural
or historic interest. Planning permission may be required for alterations and extensions which would not be
required outside of conservation areas and listed buildings. In particular, there are no permitted development
rights for roof alterations in conservation areas, and planning permission is always required. Listed buildings
and Conservation Areas may also need Listed Building Consent and Conservation Area Consent respectively.
Development must not comprise the historic and architectural integrity of the buildings. Special consideration
should be given to the following design matters:
• Established character
• Appearance
• Materials
• Boundary details
• Streetscene
• Significant trees.
32
Residential design standards October 2011
33
The physical integration of affordable housing among market housing, or ‘pepper-potting’ can cause difficulties
in terms of the affordability of service charges, which may result in the units no longer being considered
affordable as costs are taken into account when assessing the level of affordability. Where ‘pepper-potting’
can not be designed in a way to reduce the potential for high service charges in the affordable housing, it
will be discouraged. It is sometimes easier to manage housing that is grouped together, for example in flat
developments it is often more practical to integrate affordable housing by vertically grouping market and
affordable housing to ensure that service charges are kept at affordable rates. However, this does not mean
that there should be a marked difference in the quality and design of the affordable units.
Applicants are strongly encouraged to work closely with a partner Housing Association or Registered Provider
to employ their skills and experience at an early stage of design to ensure that future effective management
and maintenance of the affordable scheme can be properly considered and that the design of the development
is cost efficient.
In addition to the standards set out in this SPD, it is recommended that all affordable housing is designed to
meet the design and sustainability standards set out by the Homes and Communities Agency (HCA). From
April 2011, all London-based schemes receiving HCA funding are expected to meet the standards in the
Mayor’s Interim London Housing Design Guide. The HCA have published an interim framework for how they
will apply the Mayor’s standards (refer to Appendix 3 for the website addresses). A final design standards
framework will be published by April 2012.
Front gardens, walls, fencing and railings should be sympathetic to the character of the building and garden
and normally no higher than 1 metre. Original railings should be retained where possible. In general, rear
garden walls and fences should not exceed 2 metres to protect views and daylight.
34
Residential design standards October 2011
Porches
Porches should be in proportion to the size and character of the dwelling.
Porches should meet design requirements for extensions, as set out in
section 3.4. They should take into account the most appropriate position,
size, shape and height to complement existing buildings and harmonise
with the architectural style. They should not project beyond a bay
window. Floorspace of the porch should not exceed 2 sqm.
Satellite dishes
Satellite dishes can be visually obtrusive. They should be located at the
rear of the property and where they cannot be seen from the street and
cannot be seen against the sky. They should be positioned where their
visual impact on the appearance of the building is minimal. Suitable
sites could include within concealed roof slopes, on rear extensions or
elevations, behind chimney stacks, on back ends of garages or in the
garden. Satellite dishes will not be permitted on the front elevations of
buildings within conservation areas or on listed buildings.
35
The council supports the retention or conversion of floorspace above
shops for residential uses to provide additional and varied housing choice.
Saved Policy 3.2 of the Southwark Plan protects the amenity of residents
and occupiers including disturbance from noise. The Sustainable Design
and Construction SPD provides further guidance and requirements on
how to reduce disturbance from noise.
The proposal needs to show how the proposed housing responds to the
site and its surroundings. The building alignment, design and massing
needs to be within the context of existing neighbouring properties. The
height and scale of neighbouring properties must also be respected.
36
Residential design standards October 2011
37
3.10 Mixed–use development
Housing may be provided as part of a mixed use development. This is
most likely in local policy areas, town centres, main road frontages and
on major development sites. It can bring vitality and viability to an area
by reducing the need to travel between different activities and improve
safety and security by improving surveillance outside of normal business
areas. Mixed use development can also assist in making the best use of
scarce land by utilising the airspace above commercial buildings.
38
Residential design standards October 2011
These specialist housing types can be both self-contained, such as flats, and non self-contained, such as
hostels, houses in multiple occupation and cluster flats. In non self-contained accommodation facilities such
as kitchens, bathrooms and lounges are usually shared.
In most cases these types of housing are designed to meet the specific needs of the user group they are
intended to accommodate and therefore do not meet general needs housing because they are not necessarily
permanent housing and are only available to a specific user group. For these reasons general policy requirements
relating to housing mix and affordable housing will not normally be applied to most of these types of housing
However, as required by Core Strategy strategic policy 8, affordable housing requirements are applied to
student developments. More guidance is set out in the Affordable housing SPD.
Although our Housing Requirement Study and Strategic Housing Market Assessment do not identify a specific
for these types of housing, it is recognised that new developments may be required for certain user groups
if a local need arises. To ensure that housing for specific needs does not prejudice opportunities for general
needs housing (both market and affordable housing), applicants will be required to demonstrate that there is
a local need for such housing. In addition applicants will be asked to provide information on their experience
of delivering and managing high quality schemes of the relevant type of specialist housing.
All schemes for specialist housing should be designed and constructed to accommodate the specific
requirements of the intended residents. Where possible, schemes should also be designed to be easily adapted
to general needs housing in the event they become surplus to requirements.
Applicants are strongly encouraged to discuss proposals for housing for specific user groups at an early stage
with both our planning and housing officers.
39
4.2 Sheltered Housing and Supported Housing
Sheltered housing and supported housing give people with specific needs the opportunity to live
independently or with a degree of independence in a safe and secure environment, including
• people with physical disabilities
• older people with extra care needs and those who need support to manage their own homes
• people with mental health needs
• people with learning disabilities
• people leaving care and those setting up in new tenancies
• people with alcohol and/or substance misuse problems
• people fleeing domestic violence
• homeless people in temporary accommodation
• people at risk of offending
• people with HIV or AIDS.
Sheltered and supported housing can be in the form of hostels, residential care and nursing homes.
Accommodation can be temporary or permanent and is usually in the form of small self-contained flats or
non-self contained accommodation in the form of single rooms in a complex, with shared facilities.
Applications for special needs housing should meet the following minimum standards
• Self contained flats or studio rooms with their own bathrooms and fitted kitchens should meet the
minimum standards set out in Table 2
• Single rooms should provide a minimum size of 7.5 sq m
• Laundry facilities should be located on site and be accessible to all residents
• A communal lounge of an appropriate size should be provided that is accessible to all residents
• Communal gardens should be provided at a minimum of 50 sqm plus an additional 6.5sqm per person.
Details of the maintenance arrangements of communal gardens should be included with the application
• One guest room should be provided per 20 residents. The guest room should include a washbasin
• Details of long-term management and maintenance arrangements together with details of safety and
security measures should also be submitted with the application including supervision arrangements and
intercom and alarm systems
• All habitable rooms should have access to natural daylight. Rooms should be designed to take advantage
of natural sunlight and ventilation, as set out in section 2.7
• All bathrooms, WCs and kitchens should have adequate ventilation
• Internal space for storage of waste should be provided within kitchens (in cupboards) and should have
a minimum capacity of 30 litres and be able to store at least three bins for different types of waste. No
bin should be smaller than seven litres.
40
Residential design standards October 2011
Core Strategy policy 8 sets out that all student accommodation should be located in town centres and areas
that are easily accessible to public transport services, providing that these do not harm the local character. It
also requires 35% of student developments as affordable housing. The Affordable Housing SPD sets out more
detail guidance on implementing this policy.
41
Appendix 1
See appendix 1 of the following link for the council’s wheelchair design standards. We will keep this updated
with the latest published standards.
http://www.southwark.gov.uk/YourServices/planningandbuildingcontrol/planningpolicy/rdsspd.
html
42
Residential design standards October 2011
Appendix 2
Calculating density
There are three density standards for residential development within Southwark which are based on the
general character of the area and its accessibility by public transport. The three areas of Central Activities Zone,
Urban Zone and Suburban Zones (North, Middle and South) lie in broad bands across the borough. Density
may vary at discrete locations in opportunity areas and action area cores. These zones reflect the Density
Location and Parking Matrix in the London Plan.
Within this zone, developments should achieve densities of 650 to 1100 habitable rooms per hectare.
Development could typically be 6 to 8 storeys high, however there will be sites where taller buildings are
appropriate. The type of development will usually be flats, and will often be part of a mix of uses.
Within this zone, it is particularly important to find imaginative ways to provide amenity space for residents.
Roof terraces, winter gardens, atria, decked gardens over car parking and generous balconies should be
integrated into the overall design where appropriate.
Within this zone, developments should achieve densities of 200 to 700 habitable rooms per hectare.
It is important that the design and scale of development within this zone responds positively to the local
context. Appropriate density ranges are related to location, setting in terms of existing building form and
massing, and the index of public transport accessibility. In many cases the most efficient development of a
site will be flats, maisonettes and terraced houses rather than semi-detached, detached or linked houses with
gardens. In these developments, larger units should be provided at ground floor level wherever possible, to
ensure access to private outdoor amenity space. Alternatively, where there is commercial development on
the ground floor, access to private outdoor amenity space should be provided above it at first floor level.
Imaginative solutions should be found to provide outdoor amenity space for all residents, including those
outlined in the Central Activities Zone above. In addition, loft spaces should be used, wherever possible, to
increase the amount of internal residential floorspace.
43
A2.3 Suburban zone
Housing within this zone should retain a more open character, with larger gardens often associated with
houses rather than flats. Within this zone, developments should achieve densities of 200 - 350 habitable
rooms per hectare.
Within these areas, densities may exceed those for the Urban Zone on some sites where the increased scale
of development is appropriate in terms of design and amenity. Where the Urban Zone densities are exceeded,
the development must provide
• An exemplary standard of design, with an excellent standard of living accommodation; and
• A significant contribution to environmental improvements in the area, particularly relating to
public transport/cycle/pedestrian movement, safety and security and public realm improvements.
ii. For mixed-use development where the majority of floorspace is residential the calculation should be:
The non-residential floorspace, divided by 27.5sqm, plus;
The number of residential habitable rooms;
All divided by the site area.
44
Residential design standards October 2011
Summary calculations
(D = (NRsqm/27.5) + HR/Ha);
(Density = Non-Res floorspace divided by 27.5sqm, plus the number of
residential Habitable rooms, all divided by size in hectares).
27.5sqm is the average area required to create one habitable room,
including shared circulation space, and non-habitable rooms.
iii. For mixed-use development where the majority of floorspace is
non- residential a method of calculation should be agreed with
the LPA to illustrate how the development meets saved policy
3.11 and the contribution to housing delivery.
In cases (ii) and (iii) comparison with the density levels in A2.1, A2.2, A2.3
and A2.4 will take into account the form of the development and the
relevant advice on plot ratios in the London Plan.
45
Appendix 3
Further information
National policy and guidance
Building Research Establishment, 1991 Site Layout for Daylight and Sunlight – A Guide to Good Practice
Housing Corporation, February 2011, New Interim Funding Design and Sustainability Standards for London
See http://www.homesandcommunities.co.uk/public/documents/HCA-London-Design-Standards-Prospectus-
Feb11.doc
Housing Corporation, 2011, February 2011, London Design Proforma. See http://www.homesandcommunities.
co.uk/public/documents/HCA-London-Design-Proforma-Feb11.xls
Part M: Access to and use of buildings of the Building Regulations 2000 (2004 Edition). See www.
planningportal.gov.uk/uploads/br_PDF_ADM_2004.pdf
Department for Communities and Local Government, 2005 PPS 1: Delivering Sustainable Development. See
http://www.communities.gov.uk/publications/planningandbuilding/planningpolicystatement
Department for Communities and Local Government, 2010 Code for Sustainable Homes: Technical Guide.
See http://www.communities.gov.uk/publications/planningandbuilding/codeguide
Department for Communities and Local Government, June 2011 PPS 3: Housing See http://www.communities.
gov.uk/publications/planningandbuilding/pps3housing
Stephen Thorpe and Habinteg Housing Association, 2006 The Wheelchair Housing Design Guide
Town and Country Planning (General Development Procedure) (Amendment) (England) Order, 2006. See
www.opsi.gov.uk/SI?si2006/20061062.htm
Commission for Architecture and the Built Environment Building for Life http://www.buildingforlife.org/
46
Residential design standards October 2011
London Borough of Southwark, July 2007 The Southwark Plan (Unitary Development Plan) saved policies. See
http://www.southwark.gov.uk/YourServices/planningandbuildingcontrol/planningpolicy/southwarkplan.html
London Borough of Southwark, 2009 Southwark Housing Strategy 2009- 2016. See http://www.southwark.
gov.uk/download/3092/southwark_housing_strategy_2009_to_2016
London Borough of Southwark, 2007 Design and Access Statements SPD. See http://www.southwark.gov.uk/
info/200151/supplementary_planning_documents_and_guidance
London Borough of Southwark, 2011 Draft Affordable Housing SPD. See http://www.southwark.gov.uk/
info/200151/supplementary_planning_documents_and_guidance
London Borough of Southwark, 2009 Sustainable Design and Construction SPD. See http://www.southwark.
gov.uk/info/200151/supplementary_planning_documents_and_guidance
47
Local policy and guidance
London Borough of Southwark, April 2011, Core Strategy. See http://www.southwark.gov.uk/info/200210/
core_strategy
London Borough of Southwark, July 2007 The Southwark Plan (Unitary Development Plan) saved policies. See
http://www.southwark.gov.uk/YourServices/planningandbuildingcontrol/planningpolicy/southwarkplan.html
London Borough of Southwark, 2009 Southwark Housing Strategy 2009- 2016. See http://www.southwark.
gov.uk/download/3092/southwark_housing_strategy_2009_to_2016
London Borough of Southwark, 2007 Design and Access Statements SPD. See http://www.southwark.gov.uk/
info/200151/supplementary_planning_documents_and_guidance
London Borough of Southwark, 2011 Draft Affordable Housing SPD. See http://www.southwark.gov.uk/
info/200151/supplementary_planning_documents_and_guidance
London Borough of Southwark, 2009 Sustainable Design and Construction SPD. See http://www.southwark.
gov.uk/info/200151/supplementary_planning_documents_and_guidance
48
October 2011
Contact us
Planning policy and research team, Regeneration and neighbourhoods, Southwark Council, PO Box 64529
London SE1P 5LX
Any enquiries relating to this document can be directed to planning policy and research team, Southwark
Council. Email [email protected], Tel 020 7525 5471
If you require this document in large print, braille or audiotape please contact us on 020 7525 5548.
Peckham One Stop Shop, Peckham Library, Peckham Hill Street, SE15 5JR. Walworth One Stop Shop,
151 Walworth Road, SE17 1QY. Bermondsey One Stop Shop, 17 Spa Road, SE16.
Southwark Town Hall, 31 Peckham Road, SE5 8UB.
49
October 2011