Acceleration Head and Npsha For BR-C Closed Drain Pump

This document calculates the acceleration head and net positive suction head available (NPSHa) for different pipe configurations supplying a closed drain pump. It finds that for a 2-inch schedule 160 pipe that is 7.3 meters long, the acceleration head is 2.98 meters. However, the NPSHa of -1.8 meters is less than the required NPSHr of 1-1.19 meters, meaning the pump suction configuration is not adequate based on the calculations.

Uploaded by

Asus Asri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views

Acceleration Head and Npsha For BR-C Closed Drain Pump

This document calculates the acceleration head and net positive suction head available (NPSHa) for different pipe configurations supplying a closed drain pump. It finds that for a 2-inch schedule 160 pipe that is 7.3 meters long, the acceleration head is 2.98 meters. However, the NPSHa of -1.8 meters is less than the required NPSHr of 1-1.19 meters, meaning the pump suction configuration is not adequate based on the calculations.

Uploaded by

Asus Asri
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Acceleration head and NPSHa for BR-C Closed Drain Pump

Pha = L * v * n * C / (K * g) Outside Skid Inside Skid Inside Skid


2" Sch 160 2" Sch XXS 1.5" Sch XXS
Fluid velocity (m/s) 0.96 1.21 0.57
Pipe Length (m) 7.3 1 1 (yellow highlighted - assumed
Pump Speed (rpm) 41.77 41.77 41.77
C 0.2 0.2 0.2
K 2 2 2
g (m/s2) 9.81 9.81 9.81
Acceleration Head, Pha (m) 2.9839 0.5152 0.2427 Total

Liquid Density 838.8 kg/m3


CDV LZALL 300 mm
CDV Nozzle N5 Elevation 8427 mm
CDTP Suction Nozzle Ele. 4875 mm
(assumed sea deck)
Liquid height avail. press. 29.2 kPa

Closed Drain vessel pressure 101.325 kPaA


Vapour pressure of liquid 101.325 kPaA
Friction loss in inlet piping 12.4 kPa
Friction loss across strainer 1 kPa
(assumed)
NPSH available -1.8 m

NPSH required 1m (H2O)


1.19 m (oil)

Conclusion NPSHa<NPSHr = NOT OK!


API STANDARD 674

(yellow highlighted - assumed length)

3.74 m
30.8 kPa