Acceleration Head and Npsha For BR-C Closed Drain Pump
This document calculates the acceleration head and net positive suction head available (NPSHa) for different pipe configurations supplying a closed drain pump. It finds that for a 2-inch schedule 160 pipe that is 7.3 meters long, the acceleration head is 2.98 meters. However, the NPSHa of -1.8 meters is less than the required NPSHr of 1-1.19 meters, meaning the pump suction configuration is not adequate based on the calculations.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
86 views
Acceleration Head and Npsha For BR-C Closed Drain Pump
This document calculates the acceleration head and net positive suction head available (NPSHa) for different pipe configurations supplying a closed drain pump. It finds that for a 2-inch schedule 160 pipe that is 7.3 meters long, the acceleration head is 2.98 meters. However, the NPSHa of -1.8 meters is less than the required NPSHr of 1-1.19 meters, meaning the pump suction configuration is not adequate based on the calculations.