0% found this document useful (0 votes)
76 views

Reinforced Concrete EN5302 - Homework Chapter 3: T-Beams Homework 1

This document contains homework assignments for a reinforced concrete design course. The first assignment asks students to design a bridge girder to resist an ultimate moment of 5400 kN.m using given material properties. The second assignment asks students to calculate the design moment capacity of a hollow beam section given its dimensions and reinforcement. The third assignment asks students to design an inverted T-beam floor system for both positive and negative moments and provide detailed drawings of the required reinforcement.

Uploaded by

Rekan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
76 views

Reinforced Concrete EN5302 - Homework Chapter 3: T-Beams Homework 1

This document contains homework assignments for a reinforced concrete design course. The first assignment asks students to design a bridge girder to resist an ultimate moment of 5400 kN.m using given material properties. The second assignment asks students to calculate the design moment capacity of a hollow beam section given its dimensions and reinforcement. The third assignment asks students to design an inverted T-beam floor system for both positive and negative moments and provide detailed drawings of the required reinforcement.

Uploaded by

Rekan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Reinforced concrete EN5302 - Homework

Chapter 3: T-Beams
Homework 1
Design the bridge girder shown for an ultimate
moment of Mu = 5400 kN.m using the given
data.

fc’= 40 MPa

fy = 520 MPa

Homework 2
Compute the design moment capacity of the following hollow beam section.

 fc’= 20 MPa
 fy = 420 MPa
 Reinforcement: 9 Φ 25 mm
 Dimensions are in millimeters
 Assume reasonable values for any
missing data
Homework 3
Design the inverted T-beam shown in the following floor system for both positive and
negative moments, then draw the detailing showing the top and bottom reinforcing steel
bars.

 The columns are masonry construction


 Additional Dead Load (Superimposed DL) = 2.5 kN/m2
 Live Load : 4 kN/m2
 Slab Thickness : 150 mm
 fc’= 21 MPa , fy= 420 MPa