Questions:
1. A 11 kV, 1000 kVA, 3 phase, star connected alternator has a resistance of 2 ohm per
phase. The open circuit and full load zero power factor characteristics are given below.
Calculate the voltage regulation of the alternator for full load current at 0.8 power factor
lagging by using ZPF and ASA method. [CO1,L3]
Field current If 40 50 110 140 180
Open Circuit Voltage V 5800 7500 12500 13750 15000
ZPF Terminal Voltage 0 1500 8500 10500 12500
2. A 220 V, 50 Hz, 6 pole star connected, alternator has a resistance of 0.05 Ω per phase. It
gave the following data for open circuit, ZPF characteristics. Calculate the percentage
voltage regulation at full load current of 46.3 A at power factor of 0.8 lag by ZPF
method. [CO1,L3]
If 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.8 2.2 2.6 3.0 3.4
Voc 29 58 87 116 146 172 194 232 262 284 300 310
ZPF V - - - - - 0 29 88 140 177 208 230
CO1: After completion of the course, the students will be able to explain the concept,
principle and performance of salient and non salient type synchronous generator.
L1: Remember; L2: Understand; L3: Apply