10 Steps To LF Array Rework
10 Steps To LF Array Rework
The higher temperatures of lead-free soldering, combined with the more delicate
nature of array package components, means that suitable rework stations must
feature excellent profiling and tolerances, plus offer easy calibration if thermal
damage is to be avoided and optimum results achieved.
5. Thermal profiling
Using convection makes it easier to establish a repeatable thermal profile that won’t
overheat the package or hold it above reflow for too long. Establishing the ideal
profile takes experience, patience and knowledge of lead-free. In addition to the
standard pre-heat, soak and reflow (plus cool down) zones, lead-free demands an
extra ramp zone and more precise heating control.
8. Delta T considerations
Another factor to consider with lead-free is the temperature difference, or delta T,
across the soldering area. A delta T of 10°C is considered acceptable to produce a
good tin-lead joint, but this is halved to 5°C for lead-free, which is difficult to achieve
in practice. The second delta is vertical this is usually 10 °C from lid to solder ball,
and also the underside of the BGA this is the bottom surface of PCB under
component opposite surface of the board.
10. Inspection
Lead-free solder joints look grainy compared to traditional soldering and
inexperienced operators often reject them for quality reasons. When lead-free is
implemented, companies must set a new standard and train operators in proper
inspection criteria. X-ray inspection works well, because joint appearance is not then
an issue, but visual systems are becoming more popular due to the expense of
X-ray. There are also some newer vision systems on the market, such as Metcal's
VPI-1000 series, that feature endoscope-like technology that can look at the top and
bottom of the solder balls to check the formation of the intermetallic joint.
Array packages and lead-free processes will continue to require post production
processes and rework is not going away anytime soon. The basic rework steps are
the same, but substantial temperature differences between eutectic and lead-free
solders mean tighter processes, better temperature profiles and the use of precise
rework systems with closed-loop process control are required if high quality, low cost
rework is to be achieved.