0% found this document useful (0 votes)
218 views4 pages

Allscanner VCX PLUS HD Configuration

The document provides instructions for configuring various vehicle diagnostic applications to communicate with an Allscanner VCX PLUS/VXDIAG device connected via USB. The instructions typically involve starting the application, selecting communication settings, and choosing the VXDIAG, USB device from a list in order to enable communication between the application and the diagnostic device.

Uploaded by

kiko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
218 views4 pages

Allscanner VCX PLUS HD Configuration

The document provides instructions for configuring various vehicle diagnostic applications to communicate with an Allscanner VCX PLUS/VXDIAG device connected via USB. The instructions typically involve starting the application, selecting communication settings, and choosing the VXDIAG, USB device from a list in order to enable communication between the application and the diagnostic device.

Uploaded by

kiko
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 4

Configuring Applications to Use the Allscanner VCX PLUS/VXDIAG.

The following
examples show how to select your VCX PLUS/VXDIAG device using the USB cabling
method.
Allison DOC 8.0.0
1. Start program.
2. Click Connect to Vehicle.
3. Select the Correct Transmission Type.
4. Uncheck Smart Connect.
5. Click Connect.
6. Click Advanced Setup.
7. Select vendor of VCXRP32 Single Application.
8. Select protocol of J1939 or J1708.
9. Select correct device of VXDIAG, USB
10. Click OK.

Bendix ABS Diagnostics 6.3 v1.2.19.1


1. Start program.
2. Click on Communication device options, A. Select RP1210, A Device Using J1708 Line: VXDIAG (VXDIAG, USB)
3. Click OK.
Caterpillar Electronic Technician 2014A
1. Start Program.
2. Click Utilities  Preferences  Modify
3. Click on Communication Interface Device dropdown box.
4. Select Caterpillar Comm Adapter 3 (RP1210) or Caterpillar Comm Adapter II (RP1210)
5. Click OK
Cummins Insite 7.6.0.272
1. Start Program.
2. Click on File  Connections  Add New Connection.
3. Click Next.
4. Select RP1210 Adapter, click Next
5. Select Vendor of VXDIAG and Adapter of VXDIAG, USB, and protocol you want to use, J1708/J1939.
6. Click Next and a Connection Name screen appears.
7. Click Next and a screen prompts you to indicate whether you want to make this connection active or set up another connection.
8. Click on make this connection active.
9. Click Finish
Detroit Diesel Reprogramming System 07.09.2013
From Windows Start Menu
1. Start  Programs  Detroit Diesel  Reprogramming System  SID configure
2. Select VXDIAG, USB
3. Click OK.
From Inside DDDL
1. Tools  Options  Connections Tab  SID Configure. 2. Select VXDIAG, USB.
3. Click OK.
Eaton ServiceRanger 3.x 3.2.2.1037
1. Start Program
2. Click Eaton  ServiceRanger 3  Tools . Settings Connection
3. Under Communication Driver Information
4. Select VXDIAG, USB for both the J1587 and J1939 device.
5. Click OK.
Electronic Service Analyst 4.2.0.142 ESA (Kenworth/Peletbilt)
1. Start Program
2. Click ESA  Tools . Admin
3. General Manufacturer DLA
4. Select NEXIQ USB-Link
5. Click OK.
Freightliner ServiceLink 4.93.408.0
1. Start ServiceLink Offline
2. From the top menu bar, choose Admin.
3. From the left menu bar, choose Vehicle.
4. Click on Show All Devices.
5. In the Vendor box, choose VXDIAG Single Application.
6. Select VXDIAG, USB in the J1939 and J1708 drop down items.
7. In the CAN Device item, select the Configure button and choose VXDIAG, USB from the SID Configuration window.
8. Click Save Settings.
Hino Diagnostic eXplorer 3.1.2
1. Start Hino Diagnostic eXplorer
2. Diagnosis-login to input Password which you setup during software installation, click OK
3. Click Option(S), select communication (A), select VXDIAG, to click Config.exe
4. Click OK
Hino Reprog Manager 3.1.2
1. Start Hino Reprog Manager
2. Reprogram-login to input Password which you setup during software installation, click OK
3. Click Option(S), select communication, select VXDIAG, to click Config.exe
4. Click OK
International Truck and Engine
Diamond Logic Builder (DLB) 5.2.0.0
1. Start MD32 DLC.
2. Choose File  MD Settings COM Device
3. Select VXDIAG VXDIAG, USB
4. Click OK
Master Diagnostics (MD Fleet) 5.2.0.0
1. Start MD32 3BX
2. Choose File  MD Settings COM Device
3. Select VXDIAG VXDIAG, USB
4. Click OK
Diamond Logic Controller II 5.2.0.0
1. Start MD32 DLCII.
2. Choose File  MD Settings COM Device
3. Select VXDIAG VXDIAG, USB
4. Click OK
Meritor-WABCO ABS Toolbox 8.0.0
1. Start Meritor WABCO PC DIAGNOSTICS
2. Click System Setup; then select COM Port.
3. Select VXDIAG Single Application; the protocol to use is J1939 or J1708.
4. Select VXDIAG, USB and click OK.
PERKINS OF EST 2010B v1.0
1. Start Electronic Service Tool
2. Click Utilities to select Preferences
3. Click Communications to select RP1210 Compliant Device, then to click Advanced to select VXDIAG, USB (1)-VXDIAG
4. Click OK.

Volvo/Mack Premium Tech Tool (PTT) 1.12


1. Start Program, input User ID of m333422 or m311331, select Work offline, and click OK
2. Select Settings from the PTT menu.
3. Go to the Communication Units configuration tab, select RP1210B adapter
4. Click OK

You might also like