The document is a checklist for a PV-Genset system located in an unspecified region. It requests information about the location, whether the system is off-grid or backup, genset data including manufacturer and power ratings, load profile data, grid voltage and frequency details, economics including fuel and electricity prices, and includes a schematic of a typical Fronius PV-Genset solution and considerations for system design.

Uploaded by

Miguel Garza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views

Checklist Pv-Genset: Location

The document is a checklist for a PV-Genset system located in an unspecified region. It requests information about the location, whether the system is off-grid or backup, genset data including manufacturer and power ratings, load profile data, grid voltage and frequency details, economics including fuel and electricity prices, and includes a schematic of a typical Fronius PV-Genset solution and considerations for system design.

Uploaded by

Miguel Garza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

CHECKLIST PV-GENSET

Please fill in as accurate as possible

Location
□ Location of the PV-Genset system (Region, Country, specific GPS coordinates, altitude):

Is the planned system □ □


Off-grid (remote), or Backup (sometimes grid-tied)?
If Backup: how often/long does the system operate in backup situation
__________ hr/day
__________ days/week


Are there any local requirements (codes, standards, zero feed in) to fulfil? Yes/ □
No
If yes: Which: ________________________________________________________________________

Genset Data
Is it a □ Single Genset or □ Multi Genset system?
□ Genset manufacturer/model:_______________
Please attach datasheet of the Genset!
□ Genset-Controller:____________
□ Nominal Apparent Power of the Genset(s) in kVA.
Genset A: __________ kVA,
Genset B: __________ kVA,
Genset C: __________ kVA
□ Nominal/Maximum Active Power of the Genset(s) in kW.
Genset A: __________ / ___________ kW,
Genset B: __________ / ___________ kW,
Genset C: __________ / ___________ kW

02/2017 1/3
Load Data
□ Please attach a load profile for one year!
□ Please attach Average/Min/Max consumption (if not obvious from the load profile):
Summer Winter
Night 7-9 9-15 15-17 Night 7-9 9-15 15-17
Max
Min
Average

□ Planned PV system size in kWp:


Min. kWp.
Max. kWp.

Grid voltage / frequency


□ Nominal grid frequency: _____________ Hz
□ Nominal grid voltage (□ LV or □ MV): ____________ (k)V
□ Please attach schematic (SLD .. single line diagram) of the (existing) system.

Economics
□ Diesel price (delivered at site): ______USD or EUR per liter
or
□ Electricity price from the Genset: ______USD or EUR per kWh

Please send the PV-Genset Checklist with attachments (datasheets, load profiles) to [email protected] .

02/2017 2/3
Schematic of the Fronius PV-Genset Solution

Considerations in designing a PV-Genset Solution


/ In a typical configuration the Fronius PV-System Controller is controlling the system in a way that the Genset is
operating on at least 30% of its nominal power (configurable)
/ The Fronius PV-system controller is capable of adjusting the PV-power in a very fast way (depending on the
communication chosen with a reaction time of <2sec and a time constant of <2sec).
/ Nevertheless in the extreme event of immediate disconnection of a load larger than the operating power of the
Genset (e.g. >30%) (see in the figure below at time 11:07:19) for a very short period reverse power into the
Genset is possible. Typical Gensets do not have any problem with this short time backfeed current, but Fronius
cannot be held liable for all Genset suppliers. If the Genset has a digital controller and protection device,
reverse power can lead to shutting down the Genset. This can be avoided by a proper system design,
mitigating unwanted disconnections.

02/2017 3/3