GRUNDFOS INSTRUCTIONS

JPA, JPC, JPD PT


Pumps and boosters

Installation and operating instructions


English (GB) Installation and operating instructions
English (GB)

Original installation and operating instructions


Make sure that the system in which the
These installation and operating instructions
pump is incorporated is designed for the
describe Grundfos JPC, JPA and JPD pumps.
maximum pump pressure.
Sections 1-3 give the information necessary to be
able to unpack, install and start up the product in a
safe way. This pump has been evaluated for use with
Sections 4-8 give important information about the water only.
product, as well as information on service, fault
finding and disposal of the product.
1. General information
CONTENTS
Page 1.1 Symbols used in this document
1. General information 2 DANGER
1.1 Symbols used in this document 2
Indicates a hazardous situation which, if
2. Installing the product 3 not avoided, will result in death or serious
2.1 Checking the product prior to installation 3 personal injury.
2.2 Location 3
2.3 Mechanical installation 3 WARNING
2.4 Electrical connection 5 Indicates a hazardous situation which, if
3. Starting up the product 6 not avoided, could result in death or
3.1 Priming the pump 6 serious personal injury.
3.2 Shaft seal run-in 6
CAUTION
4. Product introduction 7
Indicates a hazardous situation which, if
4.1 JPA JPC 7
not avoided, could result in minor or
4.2 JPA PM, JPC PM, JPA PT, JPC PT 7 moderate personal injury.
4.3 JPD PT 7
4.4 Identification 8 The text accompanying the three hazard symbols
DANGER, WARNING and CAUTION is structured in
5. Servicing the product 9 the following way:
5.1 Maintaining the product 9
5.2 Spare parts and kits 9 SIGNAL WORD
6. Fault finding 10 Description of hazard
7. Technical data 11 Consequence of ignoring the warning.
- Action to avoid the hazard.
8. Disposing of the product 12
A blue or grey circle with a white graphical
Read this document and the quick guide symbol indicates that an action must be
before installing the product. Installation taken.
and operation must comply with local
regulations and accepted codes of good A red or grey circle with a diagonal bar,
practice. possibly with a black graphical symbol,
indicates that an action must not be taken
This appliance can be used by children or must be stopped.
aged from 8 years and above and by
persons with reduced physical, sensory or
mental capabilities or lack of experience Tips and advice that make the work easier.
and knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and
understand the hazards involved. If these instructions are not observed, it
Children shall not play with the appliance. may result in malfunction or damage to the
Cleaning and user maintenance shall not equipment.
be made by children without supervision.

2
2. Installing the product 2.2.1 Frost protection
If the pump is not used during periods of frost, it

English (GB)
must be drained to avoid damage.
Observe local regulations concerning
limits for manual lifting or handling. Remove the drain plug to drain the pump. See fig. 3.

CAUTION
Crushing of feet
Minor or moderate personal injury
- Use safety shoes when handling the
pump.

TM06 8026 4516


2.1 Checking the product prior to
installation
Check that the rotating parts turn freely. Position
numbers refer to fig. 1.
1. Remove the fan cover (13) from the motor.
Fig. 3 Draining the pump
2. Insert a screwdriver in the notch on the motor
shaft. 2.3 Mechanical installation
3. If the rotor is blocked, turn the screwdriver,
tapping it gently with a hammer. 2.3.1 Positioning the product
Install the pump in horizontal position.
Install the pump so that it is not stressed by the
pipes.
We recommend that you fasten the pump to the
foundation and use pipe hangers, thus ensuring that
TM06 4529 2515

vibrations caused by pump operation are absorbed.


See fig. 4.

Fig. 1 Checking the rotating parts

2.2 Location
Install the pump in a well-ventilated location,
0/Off

protected from rain, snow and direct sunlight. The 1/On

ambient temperature must not exceed 35 or 55 °C.


See the nameplate.
Max. 8 m / 26 ft

TM06 8024 4216

ãPIW

Fig. 4 Fastening the pump and the pipes


TM06 4530 2515

Fig. 2 Weather conditions

We recommend that you place the pump as close as


possible to the liquid to be pumped.

3
2.3.2 Pipe connection 2.3.3 JPD deep-well installation
A JPD must have the ejector installed in the well.
English (GB)

The internal diameters of the pipes must This means that two pipes are needed for the suction
never be smaller than that of the openings installation.
of the pump.
If the inlet pipe is longer than 10 m or the suction lift
is greater than 4 m, the diameter of the pipe must be
larger than 1". If a hose is used as inlet pipe, it must
be non-collapsible.
To prevent solids from entering the pump, you can fit
a filter to the inlet pipe. We recommend that you fit a
foot valve on the inlet side.
For suction lifts of over 4 m or for long horizontal
stretches, we recommend that you use an inlet pipe
with a diameter larger than the inlet opening of the
pump.

To prevent formation of air pockets, the


inlet pipe must slope slightly upwards
towards the pump. See fig. 5.

Up to 27 m
up to 27m

TM06 5436 4615


•FP ")
≥ 10 cm (4")

Fig. 6 JPD PT installation


TM06 4532 2515

Fig. 5 Inlet pipe sloping upwards

4
2.4 Electrical connection
DANGER

English (GB)
Carry out the electrical connection according to local
regulations. Electric shock
Death or serious personal injury
Check that the supply voltage and frequency - Power supply cables without a plug
correspond to the values stated on the nameplate must be connected to a supply
and that it is possible to make a good earth disconnecting device incorporated in
connection. the fixed wiring according to the local
Single-phase motors incorporate a thermal switch wiring rules.
and require no additional motor protection.
DANGER
DANGER
Electric shock
Electric shock
Death or serious personal injury
Death or serious personal injury - The pump must be earthed.
- Before starting any work on the product,
make sure that the power supply has 2.4.1 Wiring diagram
been switched off and that it cannot be
accidentally switched on.

DANGER
Electric shock
Death or serious personal injury
- The protective earth of the socket outlet

TM06 3322 5015


must be connected to the protective
earth of the pump. The plug must
therefore have the same PE connection
system as that of the socket outlet. If
not, use a suitable adapter.
Fig. 7 1-phase pumps
We recommend that you fit the permanent
installation with a residual-current circuit
breaker (RCCB) with a tripping current
less than 30 mA.

DANGER
Electric shock
Death or serious personal injury
- If the pump is used for cleaning or
maintenance of swimming pools,
garden ponds or similar places, make
sure that the pump is supplied through a
residual-current circuit breaker, RCCB,
with a rated residual operating current
of 30 mA.

5
3. Starting up the product
English (GB)

The pump must not run without delivering


WARNING water for more than five minutes.
Flammable material
Death or serious personal injury 3.1 Priming the pump
- Do not use the pump for flammable
liquids, such as diesel oil, petrol or 1. Remove the priming plug. See fig. 8.
similar liquids. 2. Fill the pump with water.
3. Refit the priming plug and tighten by hand.
CAUTION The pump can now be started.
Impurities in water
Minor or moderate personal injury
- Flush the system with clean water to
remove all impurities before you start
the pump.

CAUTION
Hot surface
Minor or moderate personal injury
- Do not run pump continuously with a
closed inlet or outlet valve.

WARNING
Corrosive substance
Death or serious personal injury
- Do not use the pump for aggressive
liquids.

CAUTION
Hot or cold liquid
Minor or moderate personal injury

TM06 8025 4516


- Make sure that the escaping hot or cold
liquid does not cause injury to persons
or damage to the equipment.

CAUTION
Hot surface Fig. 8 Priming the pump
Minor or moderate personal injury
- Use protective gloves if the liquid or If there is a suction lift, up to five minutes may pass
ambient temperature is higher than from the moment the pump is started until it delivers
40 °C. water. This period depends on the length and
diameter of the inlet pipe.
DANGER
Electric shock Do not start the pump until it has been
Death or serious personal injury filled with liquid.
- Do not use the pump in swimming
pools, garden ponds or similar places if
3.2 Shaft seal run-in
there are people in the water.
The seal faces are lubricated by the pumped liquid,
meaning that there may be a certain amount of
Do not start the pump until it has been leakage from the shaft seal.
filled with liquid. When the pump is started up for the first time, or
when a new shaft seal has been installed, a certain
run-in period is required before the leakage is
The pump must not be started more than reduced to an acceptable level. The time required for
20 times per hour. this depends on the operating conditions, i.e. every
time the operating conditions change, a new run-in
period will be started.
Under normal conditions, the leaking liquid will
evaporate. As a result, no leakage will be detected.

6
4. Product introduction

English (GB)
4.1 JPA JPC
JPA and JPC pumps are horizontal, self-priming
centrifugal pumps.
JPA pumps are made of cast iron, and the JPC

TM06 5408 4515


TM06 5409 4515
TM06 6703 2216
pumps are made of a composite material.
The pumps are designed for pumping water and
other thin, non-aggressive and non-explosive liquids,
not containing solid particles or fibres.
The pumps are especially suited for use in
small-scale agriculture and gardening. Fig. 11 JPA PM and PT boosters
The pumps can be permanently connected to the
water mains or connected to a hose set.

TM05 8007 2216


TM06 5406 4515
TM06 5410 4515
TM06 5411 4515

Fig. 9 JPA pumps Fig. 12 JPC PM and JPC PT

4.3 JPD PT
JPD PT are self-priming centrifugal boosters for
TM05 5091 3212

suction lifts up to 27 m. The pump body is made of


cast iron. The high suction lift is achieved by means
of an ejector which can be inserted into wells with a
diameter of down to 10 cm (4"). The boosters are
especially suited for use in small-scale agriculture
and water supply to farmhouses.
Fig. 10 JPC pump

4.2 JPA PM, JPC PM, JPA PT, JPC PT

TM06 5413 4515 - TM06 5415 4515


JPA PM and JPC PM are compact boosters
consisting of a JPA pump and a Grundfos Pressure
Manager (PM 1 version). To reduce the number of
starts and stops, an external tank can be installed.
JPA PT and JPC PT are boosters consisting of a
pump, a pressure switch, a pressure gauge and a
diaphragm tank. The pressure switch automatically
starts the pump according to demand. The
diaphragm tank ensures a constant water pressure
in the water supply.

Fig. 13 JPD boosters

7
4.4 Identification
2 3
English (GB)

2 3

DK-8850 Bjerringbro Denmark


1 Type: JPD 4-47 No: 98946103 P51. 1549 4
DK-8850 Bjerringbro Denmark
1 Type: JPA 3-42 No: 98946090 P4 15 47 4 17 U: 1x230 V~ I1/1: 4.22 A 50Hz P1: 0.86 kW
5
16 μF / 450 V~ Class: F IP: 44 P2: 0.75 HP
17 U: 1x230 V~ I1/1: 3,12 A 50Hz P1: 0,72 kW
5 16 6
3
12,5 μF / 450 V~ Class: F IP: 44 P2: 0,6 HP Q: 0.12-2.38 m /h H: 35-15 m Hmix: m
16 6 15 18
n: 2800 min -1 Hmax: m

TM06 7713 4016


3
Q: 0,4-2,7 m /h H: 38-21 m Hmix: 21 m 14
15 18 pmax : 0.6/6 Mpa/bar Tmax: 35ºC 19
n: 2800 min -1 Serial nr.146783 Hmax: 42 m 21

TM06 7712 4016


14 19
Q&H performed
with Ejector E25
7
pmax : 0.8/8 Mpa/bar Tmax: 35ºC
21 7 13 PCS 00084.01 04-6292.2.41
LSPr-002-IDN
& suction depth 9m

Made in China by Grundfos NPB 119-116-111053

13 8
Made in Hungary by Grundfos
8 12 11 10 9
12 20 11 10 9 Fig. 16 Nameplate, JPD
Fig. 14 Nameplate, JPA
Pos. Description
2 3 1 Pump type
2 Product number
3 Full-load current
DK-8850 Bjerringbro Denmark
1 Type: JPC 4-47 No:99074057 P4 1.1628 4 4 Factory and production date
17 U: 1x220-240 V~ I1/1:3.8A 50Hz P1:0.85
5 5 Motor input power
16 12.5μF / 450 V~ Class:F IP:44 P2:0.8HP
6 6 Pump output power
15 Q: 0.4-3.6 m 3 /h H: 41-20 m Tmax:55ºC
-1
7 7 Maximum temperature
TM06 7303 3616

n: 2800 min Made in Hungary by Grundfos


14 8 8 Country of production
13 9 Frequency
10 Enclosure class
12 11 10 9
11 Motor insulation class
Fig. 15 Nameplate, JPC 12 Head
13 Approvals
14 Speed
15 Maximum flow rate
16 Capacitor data
17 Supply voltage
18 Minimum head
19 Maximum head
20 Serial number
21 Maximum pressure

8
5. Servicing the product

English (GB)
5.1 Maintaining the product
In normal operation, the pump does not require any
specific maintenance.
5.1.1 Safety instructions and requirements

DANGER
Electric shock
Death or serious personal injury
- If the power supply cable is damaged, it
must be replaced by the manufacturer,
his service agent or similarly qualified
persons in order to avoid hazard.

Service must only be performed by trained


service staff.

5.2 Spare parts and kits


Service kits are available for the JPA, JPC, JPD
pumps and boosters.
The service kits consist of the following replaceable
parts:
• shaft seal
• hydraulic parts
• capacitor.

9
6. Fault finding
English (GB)

DANGER
Electric shock
Death or serious personal injury
- Switch off the power supply before
starting any work on the product. Make
sure that the power supply cannot be
accidentally switched on.

Fault Cause Remedy

1. The pump does a) Supply failure. Cut in the circuit breaker or replace the fuses.
not start. If the new fuses also blow, check the electric
installation.
b) The pump is blocked by Clean the pump. Check or replace the strainer
impurities. in the inlet pipe.
c) The motor is defective. Replace the pump.
2. The pump runs, a) The pump is not filled with Prime the pump. See section 3. Starting up the
but gives no or just water. product.
a little water.
b) The inlet pipe is blocked by Clean the inlet pipe. Check or replace the
impurities. strainer in the inlet pipe.
c) The pump is blocked by Clean the pump. Check or replace the strainer
impurities. in the inlet pipe.
d) The suction lift is too high.
JPA, JPC: Maximum 7 m. Change the position of the pump.
JPD: Maximum 27 m.
e) The inlet pipe is too long. Change the position of the pump.
f) The diameter of the inlet pipe
Replace the inlet pipe.
is too small.
g) The inlet pipe is not immersed Make sure that the inlet pipe is immersed
deeply enough. sufficiently.
h) The inlet pipe is leaking. Repair or replace the pipe.
3. The pump runs, a) The outlet pipe is blocked.
but gives no water Clean the pipe or open the isolating valves, if
or delivers a fitted.
reduced quantity Check that no additional work is being carried
of water at high out in the system.
pressure.
4. The motor cuts out a) The thermal switch in the The thermal switch will cut in automatically
during operation. motor has tripped due to when the motor has cooled sufficiently.
overheating. If the problem persists, check these two
possible causes:
• The impeller is stuck.
Clean the pump.
• The motor is defective.
Replace the pump.

10
7. Technical data Maximum head

English (GB)
Maximum ambient temperature Pump type [m]
35 or 55 °C. See the nameplate.
JPA 3-42 / JPA 3-42 PT-H 42
Liquid temperature
Domestic use: 0-35 °C or 0-60 °C. See the JPA 4-47 / JPA 4-47 PT-H /
47
nameplate. JPA 4-47 PT-V
Other use: 0-40 °C. JPA 4-54 / JPA 4-54 PT-H /
54
JPA 4-54 PT-V
Maximum operating pressure
6 bar, 600 kPa. JPA 5-61 / JPA 5-61 PT-V 61

Maximum flow rate JPA 8-62 / JPA 8-62 PT-V 62


JPA 12-41 41
Pump type [m3/h] JPA 12-51 51
JPA 3-42 / JPA 3-42 PT-H 3 JPC 3-42 / JPC 3-42 PT 42
JPA 4-47 / JPA 4-47 PT-H / JPC 4-47 / JPC 4-47 PT 47
4
JPA 4-47 PT-V
JPC 4-54 / JPC 4-54 PT 54
JPA 4-54 / JPA 4-54 PT-H /
4 JPC 5-48 48
JPA 4-54 PT-V
JPA 5-61 / JPA 5-61 PT-V 5 JPD 4-47 PT 47

JPA 8-62 / JPA 8-62 PT-V 8 JPD 4-54 PT 54

JPA 12-41 12 JPD 5-61 PT 61

JPA 12-51 12 JPD 8-62 PT 62

JPC 3-42 / JPC 3-42 PT 3 Maximum inlet pressure


JPC 4-47 / JPC 4-47 PT 4
Pump type [bar] [MPa]
JPC 4-54 / JPC 4-54 PT 4
JPA 3-42 / JPA 3-42 PT-H 3.8 0.38
JPC 5-48 5
JPA 4-47 / JPA 4-47 PT-H /
JPD 4-47 PT 4 3.3 0.33
JPA 4-47 PT-V
JPD 4-54 PT 4
JPA 4-54 / JPA 4-54 PT-H /
2.6 0.26
JPD 5-61 PT 5 JPA 4-54 PT-V
JPD 8-62 PT 8 JPA 5-61 / JPA 5-61 PT-V 1.9 0.19
JPA 8-62 / JPA 8-62 PT-V 1.8 0.18
JPA 12-41 3.9 0.39
JPA 12-51 2.9 0.29
JPC 3-42 / JPC 3-42 PT 1.8 0.18
JPC 4-47 / JPC 4-47 PT 1.3 0.13
JPC 4-54 / JPC 4-54 PT 0.6 0.06
JPC 5-48 1.2 0.12
JPD 4-47 PT 1.3 0.13
JPD 4-54 PT 0.6 0.06
JPD 5-61 PT 1.9 0.19
JPD 8-62 PT 1.8 0.18

Maximum suction lift


JPA, JPC: 8 m, including a pressure loss, at a liquid
temperature of 20 °C.
JPD: 27 m.

11
Supply voltage
English (GB)

JPA JPC JPD

1 x 115 V, 60 Hz - ● -
1 x 230 V, 60 Hz - ● -
1 x 230 V, 50 Hz ● ● ●

Insulation class
F.
Enclosure class
IP44.
Relative air humidity
Maximum 95 %.
Maximum sound pressure level
JPA, JPD: less than 77 dB(A).
JPC 3-42: 82.9 dB.
JPC 4-47: 84.8 dB.
JPC 4-54: 88.0 dB.
Frequency of starts and stops
Maximum 20 per hour.

8. Disposing of the product


This product or parts of it must be disposed of in an
environmentally sound way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest
Grundfos company or service workshop.
See also end-of-life information on
www.grundfos.com.
The crossed-out wheelie bin symbol on
a product means that it must be
disposed of separately from household
waste. When a product marked with this
symbol reaches its end of life, take it to a
collection point designated by the local
waste disposal authorities. The separate collection
and recycling of such products will help protect the
environment and human health.

12
13
Argentina China Hong Kong
Grundfos companies

Bombas GRUNDFOS de Argentina S.A. GRUNDFOS Pumps (Shanghai) Co. Ltd. GRUNDFOS Pumps (Hong Kong) Ltd.
Ruta Panamericana km. 37.500 Centro 10F The Hub, No. 33 Suhong Road Unit 1, Ground floor
Industrial Garin Minhang District Siu Wai Industrial Centre
1619 Garín Pcia. de B.A. Shanghai 201106 29-33 Wing Hong Street &
Phone: +54-3327 414 444 PRC 68 King Lam Street, Cheung Sha Wan
Telefax: +54-3327 45 3190 Phone: +86 21 612 252 22 Kowloon
Telefax: +86 21 612 253 33 Phone: +852-27861706 / 27861741
Australia Telefax: +852-27858664
GRUNDFOS Pumps Pty. Ltd. COLOMBIA
P.O. Box 2040 GRUNDFOS Colombia S.A.S. Hungary
Regency Park Km 1.5 vía Siberia-Cota Conj. Potrero GRUNDFOS Hungária Kft.
South Australia 5942 Chico, Tópark u. 8
Phone: +61-8-8461-4611 Parque Empresarial Arcos de Cota Bod. H-2045 Törökbálint,
Telefax: +61-8-8340 0155 1A. Phone: +36-23 511 110
Cota, Cundinamarca Telefax: +36-23 511 111
Austria Phone: +57(1)-2913444
GRUNDFOS Pumpen Vertrieb Telefax: +57(1)-8764586 India
Ges.m.b.H. GRUNDFOS Pumps India Private
Grundfosstraße 2 Croatia Limited
A-5082 Grödig/Salzburg GRUNDFOS CROATIA d.o.o. 118 Old Mahabalipuram Road
Tel.: +43-6246-883-0 Buzinski prilaz 38, Buzin Thoraipakkam
Telefax: +43-6246-883-30 HR-10010 Zagreb Chennai 600 096
Phone: +385 1 6595 400 Phone: +91-44 2496 6800
Belgium Telefax: +385 1 6595 499
N.V. GRUNDFOS Bellux S.A. www.hr.grundfos.com Indonesia
Boomsesteenweg 81-83 PT. GRUNDFOS POMPA
B-2630 Aartselaar GRUNDFOS Sales Czechia and Graha Intirub Lt. 2 & 3
Tél.: +32-3-870 7300 Slovakia s.r.o. Jln. Cililitan Besar No.454. Makasar,
Télécopie: +32-3-870 7301 Čajkovského 21 Jakarta Timur
779 00 Olomouc ID-Jakarta 13650
Belarus Phone: +420-585-716 111 Phone: +62 21-469-51900
Представительство ГРУНДФОС в Telefax: +62 21-460 6910 / 460 6901
Минске Denmark
220125, Минск GRUNDFOS DK A/S Ireland
ул. Шафарнянская, 11, оф. 56, БЦ Martin Bachs Vej 3 GRUNDFOS (Ireland) Ltd.
«Порт» DK-8850 Bjerringbro Unit A, Merrywell Business Park
Тел.: +7 (375 17) 286 39 72/73 Tlf.: +45-87 50 50 50 Ballymount Road Lower
Факс: +7 (375 17) 286 39 71 Telefax: +45-87 50 51 51 Dublin 12
E-mail: [email protected] E-mail: [email protected] Phone: +353-1-4089 800
www.grundfos.com/DK Telefax: +353-1-4089 830
Bosnia and Herzegovina
GRUNDFOS Sarajevo Estonia Italy
Zmaja od Bosne 7-7A, GRUNDFOS Pumps Eesti OÜ GRUNDFOS Pompe Italia S.r.l.
BH-71000 Sarajevo Peterburi tee 92G Via Gran Sasso 4
Phone: +387 33 592 480 11415 Tallinn I-20060 Truccazzano (Milano)
Telefax: +387 33 590 465 Tel: + 372 606 1690 Tel.: +39-02-95838112
www.ba.grundfos.com Fax: + 372 606 1691 Telefax: +39-02-95309290 / 95838461
e-mail: [email protected]
Finland Japan
Brazil OY GRUNDFOS Pumput AB GRUNDFOS Pumps K.K.
BOMBAS GRUNDFOS DO BRASIL Trukkikuja 1 1-2-3, Shin-Miyakoda, Kita-ku,
Av. Humberto de Alencar Castelo FI-01360 Vantaa Hamamatsu
Branco, 630 Phone: +358-(0) 207 889 500 431-2103 Japan
CEP 09850 - 300 Phone: +81 53 428 4760
São Bernardo do Campo - SP France Telefax: +81 53 428 5005
Phone: +55-11 4393 5533 Pompes GRUNDFOS Distribution S.A.
Telefax: +55-11 4343 5015 Parc d’Activités de Chesnes Korea
57, rue de Malacombe GRUNDFOS Pumps Korea Ltd.
Bulgaria F-38290 St. Quentin Fallavier (Lyon) 6th Floor, Aju Building 679-5
Grundfos Bulgaria EOOD Tél.: +33-4 74 82 15 15 Yeoksam-dong, Kangnam-ku, 135-916
Slatina District Télécopie: +33-4 74 94 10 51 Seoul, Korea
Iztochna Tangenta street no. 100 Phone: +82-2-5317 600
BG - 1592 Sofia Germany Telefax: +82-2-5633 725
Tel. +359 2 49 22 200 GRUNDFOS GMBH
Fax. +359 2 49 22 201 Schlüterstr. 33 Latvia
email: [email protected] 40699 Erkrath SIA GRUNDFOS Pumps Latvia
Tel.: +49-(0) 211 929 69-0 Deglava biznesa centrs
Canada Telefax: +49-(0) 211 929 69-3799 Augusta Deglava ielā 60, LV-1035, Rīga,
GRUNDFOS Canada Inc. e-mail: [email protected] Tālr.: + 371 714 9640, 7 149 641
2941 Brighton Road Service in Deutschland: Fakss: + 371 914 9646
Oakville, Ontario e-mail: [email protected]
L6H 6C9 Lithuania
Phone: +1-905 829 9533 Greece GRUNDFOS Pumps UAB
Telefax: +1-905 829 9512 GRUNDFOS Hellas A.E.B.E. Smolensko g. 6
20th km. Athinon-Markopoulou Av. LT-03201 Vilnius
P.O. Box 71 Tel: + 370 52 395 430
GR-19002 Peania Fax: + 370 52 395 431
Phone: +0030-210-66 83 400
Telefax: +0030-210-66 46 273
Malaysia Serbia Turkey

Grundfos companies
GRUNDFOS Pumps Sdn. Bhd. Grundfos Srbija d.o.o. GRUNDFOS POMPA San. ve Tic. Ltd.
7 Jalan Peguam U1/25 Omladinskih brigada 90b Sti.
Glenmarie Industrial Park 11070 Novi Beograd Gebze Organize Sanayi Bölgesi
40150 Shah Alam Phone: +381 11 2258 740 Ihsan dede Caddesi,
Selangor Telefax: +381 11 2281 769 2. yol 200. Sokak No. 204
Phone: +60-3-5569 2922 www.rs.grundfos.com 41490 Gebze/ Kocaeli
Telefax: +60-3-5569 2866 Phone: +90 - 262-679 7979
Singapore Telefax: +90 - 262-679 7905
Mexico GRUNDFOS (Singapore) Pte. Ltd. E-mail: [email protected]
Bombas GRUNDFOS de México S.A. de 25 Jalan Tukang
C.V. Singapore 619264 Ukraine
Boulevard TLC No. 15 Phone: +65-6681 9688 Бізнес Центр Європа
Parque Industrial Stiva Aeropuerto Telefax: +65-6681 9689 Столичне шосе, 103
Apodaca, N.L. 66600 м. Київ, 03131, Україна
Phone: +52-81-8144 4000 Slovakia Телефон: (+38 044) 237 04 00
Telefax: +52-81-8144 4010 GRUNDFOS s.r.o. Факс.: (+38 044) 237 04 01
Prievozská 4D E-mail: [email protected]
Netherlands 821 09 BRATISLAVA
GRUNDFOS Netherlands Phona: +421 2 5020 1426 United Arab Emirates
Veluwezoom 35 sk.grundfos.com GRUNDFOS Gulf Distribution
1326 AE Almere P.O. Box 16768
Postbus 22015 Slovenia Jebel Ali Free Zone
1302 CA ALMERE GRUNDFOS LJUBLJANA, d.o.o. Dubai
Tel.: +31-88-478 6336 Leskoškova 9e, 1122 Ljubljana Phone: +971 4 8815 166
Telefax: +31-88-478 6332 Phone: +386 (0) 1 568 06 10 Telefax: +971 4 8815 136
E-mail: [email protected] Telefax: +386 (0)1 568 06 19
E-mail: [email protected] United Kingdom
New Zealand GRUNDFOS Pumps Ltd.
GRUNDFOS Pumps NZ Ltd.
South Africa Grovebury Road
17 Beatrice Tinsley Crescent Grundfos (PTY) Ltd. Leighton Buzzard/Beds. LU7 4TL
North Harbour Industrial Estate 16 Lascelles Drive, Meadowbrook Estate Phone: +44-1525-850000
Albany, Auckland 1609 Germiston, Johannesburg Telefax: +44-1525-850011
Phone: +64-9-415 3240 Tel.: (+27) 10 248 6000
Telefax: +64-9-415 3250 Fax: (+27) 10 248 6002 U.S.A.
E-mail: [email protected] GRUNDFOS Pumps Corporation
Norway 9300 Loiret Blvd.
GRUNDFOS Pumper A/S
Spain Lenexa, Kansas 66219
Strømsveien 344 Bombas GRUNDFOS España S.A. Phone: +1-913-227-3400
Postboks 235, Leirdal Camino de la Fuentecilla, s/n Telefax: +1-913-227-3500
N-1011 Oslo E-28110 Algete (Madrid)
Tlf.: +47-22 90 47 00 Tel.: +34-91-848 8800 Uzbekistan
Telefax: +47-22 32 21 50 Telefax: +34-91-628 0465 Grundfos Tashkent, Uzbekistan The Rep-
resentative Office of Grundfos Kazakhstan
Poland Sweden in Uzbekistan
GRUNDFOS Pompy Sp. z o.o. GRUNDFOS AB 38a, Oybek street, Tashkent
ul. Klonowa 23 Box 333 (Lunnagårdsgatan 6) Телефон: (+998) 71 150 3290 / 71 150
Baranowo k. Poznania 431 24 Mölndal 3291
PL-62-081 Przeźmierowo Tel.: +46 31 332 23 000 Факс: (+998) 71 150 3292
Tel: (+48-61) 650 13 00 Telefax: +46 31 331 94 60
Fax: (+48-61) 650 13 50 Switzerland Addresses Revised 15.01.2019
Portugal GRUNDFOS Pumpen AG
Bombas GRUNDFOS Portugal, S.A. Bruggacherstrasse 10
Rua Calvet de Magalhães, 241 CH-8117 Fällanden/ZH
Apartado 1079 Tel.: +41-44-806 8111
P-2770-153 Paço de Arcos Telefax: +41-44-806 8115
Tel.: +351-21-440 76 00 Taiwan
Telefax: +351-21-440 76 90 GRUNDFOS Pumps (Taiwan) Ltd.
Romania 7 Floor, 219 Min-Chuan Road
GRUNDFOS Pompe România SRL Taichung, Taiwan, R.O.C.
Bd. Biruintei, nr 103 Phone: +886-4-2305 0868
Pantelimon county Ilfov Telefax: +886-4-2305 0878
Phone: +40 21 200 4100 Thailand
Telefax: +40 21 200 4101 GRUNDFOS (Thailand) Ltd.
E-mail: [email protected] 92 Chaloem Phrakiat Rama 9 Road,
Russia Dokmai, Pravej, Bangkok 10250
ООО Грундфос Россия Phone: +66-2-725 8999
ул. Школьная, 39-41 Telefax: +66-2-725 8998
Москва, RU-109544, Russia
Тел. (+7) 495 564-88-00 (495) 737-30-
00
Факс (+7) 495 564 8811
E-mail [email protected]
ECM: 1252450
99022277 0119

www.grundfos.com
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be
think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved. © 2019 Grundfos Holding A/S, all rights reserved.

You might also like