50% found this document useful (2 votes)
5K views14 pages

Fault Code 800101 Emergency Stop Fault 2017

The document provides information about fault code 800101 "Emergency Stop Activated" that may occur on Sandvik mobile crushers and screens. It describes how to reset an emergency stop that has been activated by turning the stop button clockwise. It also provides details on testing components of the emergency stop system, including checking continuity of wires and replacing fuses, to diagnose the cause of the fault.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
50% found this document useful (2 votes)
5K views14 pages

Fault Code 800101 Emergency Stop Fault 2017

The document provides information about fault code 800101 "Emergency Stop Activated" that may occur on Sandvik mobile crushers and screens. It describes how to reset an emergency stop that has been activated by turning the stop button clockwise. It also provides details on testing components of the emergency stop system, including checking continuity of wires and replacing fuses, to diagnose the cause of the fault.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 14

SANDVIK MOBILE CRUSHERS & SCREENS

FAULT CODE 800101 EMERGENCY STOP ACTIVATED

Rev 2 – 01-10-18
SAFETY FIRST

Sandvik‘s objective is zero harm to our


people, the environment we work in,
our customers and our suppliers.

PROTECTIVE FIRST AID


ALARM
EQUIPMENT KIT

EMERGENCY EMERGENCY ASSEMBLY


NUMBER EXIT POINT

PSYCHOLOGICAL
SAFETY

2
GLOBAL INTERNAL CONTROLS
Control leads to

The Way We All Operate compliance !

Ensure
compliance
We all need to
with all relevant
be compliant
internal and
external rules
and regulation

Conducting
business with
‘Power of ethics and
Sandvik’ are integrity
the guidelines
for all
employees
QUALITY FOCUS

ZERO DEFECTS TO CUSTOMER


Sandvik aims to be THE preferred and
recurrent supplier in Mobile Crushing and
Screening

4
HEALTH AND SAFETY

5
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
COMPONENT LOCATION QA MODELS

Push the stop to


stop the machine

To reset the Emergency


Stop Turn the button
clockwise

6
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
COMPONENT LOCATION QE MODELS

Push the stop to


stop the machine

To reset the Emergency


Stop Turn the button
clockwise

7
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
COMPONENT LOCATION

Pressing the stop button on the Ensure the dummy plug or the
handset requests engine stop handset are plugged in. If not then
Fault 800102 will be activated

8
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
SYSTEM LOGIC 2017 SYSTEM

Emergency Stop Emergency Stop


Switches Closed System Healthy 800101
System Error !
Emergency Stop Activated

Fault 800101

Emergency Emergency Stop Pressed Emergency Emergency


Stop or Open Circuit Stop Activated Stop Activated

Error code Error message Description Action


101 Emergency stop Emergency stop pressed Engine Shutdown
Activated or open circuit

9
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
EMERGENCY STOP SYSTEM (2017)

Breakout Module
C25 Pin 1
10A

Pin 4

Pin 2

Pin 3

Fuse/Relay
Module

K60 K61

Supply to Run
Solenoid
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
COMPONENT TESTING 2017
Healthy Estop switch

When a button is pressed both the positive and negative circuits are
open circuit removing power and negative to the fuel solenoid stopping
the engine. To fuel solenoid Negative
Test both Positive and negative circuits for continuity.

Check power supply and fuse C25, 10 amp found in the electrical
diagrams.

Check there is a good earth within the system.

Power supply From control


or Negative module
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
COMPONENT TESTING 2017

• The emergency stop fault needs both positive and negative


channels to be broken. Or shorted together.

• Check all the stop buttons are not pushed in and released.

• Check continuity of both channels these need to be closed


circuit with a resistance less than 1 Ohm. If it is above this
then all the Estop buttons, contactors, cables and plugs in
the circuit will need to be tested and replaced repaired as
necessary.

• There are 6 sockets in breakout module.

• If less then 6 stops are fitted on the machine then the


blanking plugs need to be fitted in place off the stops.

• Check Fuses F1, 15 amp in the panel module and F25, 10


amp in the breakout module and replace and if necessary.
FAULT CODE 800101 EMERGENCY STOP ACTIVATED
COMPONENT TESTING 2017

• Remove plug C22 and Plug C23 test the continuity in the wiring plugs not the breakout
module sockets, on C23 wire 1 to wire 2 on C22 and C23 wire 3 to C22 wire 4 on the face
of the plug.

• If an open circuit is found remove all the plugs and test the stops individually to locate the
faulty circuit and replace as necessary

• Check across wires 1 and 3 on plug 22 for open circuit if a short circuit is found then test
each stop individually and check for damaged cables.