0% found this document useful (0 votes)
104 views1 page

Purlin Design Astino Project

This document summarizes the design of a simply supported purlin with one sag rod. It provides properties of the C-shaped purlin section, span and loading data. Bending is calculated about the x and y axes. Stress is within allowable limits. Deflection under dead and live loads is also checked and acceptable. The maximum sag rod load is calculated as 4.85 kN, requiring a minimum 14mm diameter rod through a 12mm hole at midspan.

Uploaded by

Salvatore Shw
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views1 page

Purlin Design Astino Project

This document summarizes the design of a simply supported purlin with one sag rod. It provides properties of the C-shaped purlin section, span and loading data. Bending is calculated about the x and y axes. Stress is within allowable limits. Deflection under dead and live loads is also checked and acceptable. The maximum sag rod load is calculated as 4.85 kN, requiring a minimum 14mm diameter rod through a 12mm hole at midspan.

Uploaded by

Salvatore Shw
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Design of a Simply Support Purlin With One Sag Rod

Project : NJT Copper Tube (Malaysia) Sdn Bhd


Date : 27/4/2020

Section : 225 x 75 x 16 x 2.5 mm thk C Purlin


Code No. : ACP22525

Section Properties
Modulus Of Elasticity,(E) = 2.00 x 105 N/mm2
Second Moment Of Area,(Ixx) = 7.35 x 106 mm4
Second Moment Of Area,(Iyy) = 0.65 x 106 mm4
3
Second Modulus,(Zxx) = 65.33 x 10 mm3
3
Second Modulus,(Zyy) = 32.87 x 10 mm3
2
Yield Strength,(py) = 450 N/mm

Span Data
Pitch = 5 ˚
Span = 9285 mm
Length of roof on plan = 11902 mm
Length of roof on slope = 11947.5 mm
Spacing on plan = 1200 mm
Spacing on slope = 1204.58 mm

Loading
Dead Load,(DL)
1) Self-weight = 7.98 x 9.807 x 10-3 = 0.078 kN/m
2) Matel Roofing = 7 x 9.807 x 10-3 x 1.200 / (cos 5 ˚) = 0.083 kN/m
3) Insulation, 50 mm = 0.05 x 43 x 9.807 x 10-3 x 1.200 / (cos 5 ˚) = 0.025 kN/m
4) M&E Services = 0.4 x 1.200 = 0.480 kN/m
5) Ceiling = 0.00 x 9.807 x 10-3 x 1.200 = 0.000 kN/m
6) Other = 0.00 x 9.807 x 10-3 x 1.200 = 0.000 kN/m
0.666 kN/m
Live Load,(LL)
1) Allow = 0.25 x 1.200 = 0.300 kN/m
2) Other = x 1.200 = 0.000 kN/m
0.300 kN/m

FACTORED LOAD 1.413 kN/m

Bending
About x-x axis: About y-y axis:
1.408 kN/m 0.123 kN/m

9285 4642.5 4643

3.08 3.08 0.10 0.34 0.10


1.39 1.39 0.05 0.15 0.05

0.33 kNm

0.19 kNm 0.19 kNm

15.17 kNm

Check Moment Capacity


For x-x axis:
Actual Bending Stress(pxx(Actual)) = 232.16
For y-y axis:
Actual Bending Stress(pyy(Actual)) = 10.09
Combined Stress = 232.16 + 10.09 = 242.25 N/mm2 < 450 N/mm2

Therefore : The Section Is Satisfactory

Check Deflection
For x-x axis: l/D = 180
D, Allowable = 50 mm
Dead Load: D = 43.9 mm OK
Live Load: D = 19.8 mm OK

Sag Rod Design:


Maximum Sag Rod Load = 11947.5 / 1204.58 x 0.49 = 4.85 kN
Minimum Ø Required = 12 mm Ø of hole @ midspan = 14 mm