Trane Residential and Light Commercial Products Handbook
Trane Residential and Light Commercial Products Handbook
This handbook does not contain data such as ARI system ratings,
performance tables, etc… If you require this information, you should always
refer to the most current Trane Product Data Catalog.
Thank you for the opportunity to provide you with an updated Trane handbook.
Effective 1/1/06
Contents
Air Handler -
Residential
Accessories
Furnaces
15 - Digit
Air Handler -
Commercial
Heat Pump/
Gas Furnaces Cooling Coils
Oil Furnaces
Oil Furnace
Accessories
TRANE
Furnace Coils CleanEffects™
Whole House
Air Cleaner
Perfect Fit™
Air Cleaner
TXV Kits
Humidifiers Humidifier
Controls
Energy
Humidifier Recovery
Accessories Ventilator
(ERV)
Precedent™
Units
Precedent™
13 SEER Units
Ductless
Comfort Outdoor Units
Controls
Ductless
Air Conditioners
Integrated Zone™
System
Horizontal Model S
Blower Assembly Unit Heater
Electric Wall
MountedUnit
Heaters
Model UHWA
Electric Explosion
Proof Unit Heaters
Model UHXA
Electric
Architectural
Wall Heaters
Model UHAA
XL16i
Table SC-1-C — XL15i Split System Cooling — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TTX5024A1000A 208/230/1/60 24,000 TXV-NB 46 37 34 283 72 14 20 /4 /16
3 5
2TTX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 284 74 16 25 /4 /16
7 3
2TTX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 300 72 18 30 /8 /8
7 3
2TTX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 307 73 23 35 /8 /8
2TTX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 337 72 26 40 11/8 3
/8
XR 14 XR 14 XR 13
Table SC-4-A — Features (2TTR4) (4TTR4) (2TTR3)
• SEER’s up to ............................................................................................................................................. 14.00 14.00 14.00
• Climatuff™ compressor ........................................................................................................................... ✔ ✔ ✔
• Comfort”R”™ mode approved ................................................................................................................ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ................................................................................ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ........................ ✔ ✔ ✔
• Spine Fin™ coil ........................................................................................................................................ ✔ ✔ ✔
• Compressor sound enclosure ................................................................................................................... ✔ ✔ ✔
• Compressor sump heat - factory installed ................................................................................................. 1½-2,3½-5 1½-2 5
• Factory supplied charge ............................................................................................................................ R-22 R-410A R-22
• Glossy corrosion resistant finish ............................................................................................................... ✔ ✔ ✔
• High pressure switch ................................................................................................................................. — ✔ —
• Internal high / low pressure & temperature protection ............................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed ...................................................................................................... ✔ ✔ ✔
• Quick start kit - factory installed ................................................................................................................ 1½-2,5 1½-2,5 1½-2½,3½-5
• Tarpaulin gray cabinet ............................................................................................................................... ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ............................ ✔ ✔ ✔
• Extended warranties available ............................................................................................................... ✔ ✔ ✔
PHASED OUT
3 5
4TTR2030A1000A 208-230/1/60 30,000 .059 33 33 30 218 74 20 30 /4 /16
3 3
4TTR2036A1000A 208-230/1/60 36,000 .065 33 33 30 231 77 21 35 /4 /8
3 3
4TTR2042A1000A 208-230/1/60 42,000 .071 37 33 30 243 78 25 40 /4 /8
7 3
XR12 4TTR2048A1000A 208-230/1/60 48,000 .077 41 33 30 260 79 31 50 /8 /8
4TTR2060A1000A 208-230/1/60 60,000 1 33 37 34 283 81 36 60 7
/8 3
/8
XR12
PHASED OUT
2TTR2036A1000A
2TTR2042B1000A
2TTR2048A1000A
2TTR2060B1000A
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
36,000
42,000
48,000
60,000
.071
.077
.086
1
33
33
37
41
29
33
33
37
26
30
30
34
195
228
247
270
79
79
78
79
21
23
26
33
35
40
45
50
7
7
/8
/8
1 1/8
1 1/8
3
3
/8
/8
/8
/8
PHASED OUT
7 3
2TTR1036A1000A 200-230/1/60 36,000 .073 26 29 26 177 77 22 35 /8 /8
7 3
2TTR1042A1000A 200-230/1/60 42,000 .075 29 29 26 212 79 24 40 /8 /8
2TTR1048A1000A 200-230/1/60 48,000 .083 29 29 26 219 79 29 50 11/8 3
/8
XR11 2TTR1060A1000A 200-230/1/60 60,000 1 37 33 30 269 79 36 60 11/8 3
/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
XR 12 XR 12 XR 11
Table SC-6-A — Features (4TTR2) (2TTR2) (2TTR1)
T
• SEER’s up to .......................................................................................................................................................................... 13 13 11.5
OU
• Climatuff™ compressor ........................................................................................................................................................ ✔ ✔ ✔
• Comfort”R”™ mode approved .............................................................................................................................................. ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof .............................................................................................................. ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ....................................................... ✔ ✔ ✔
ED
• Spine Fin™ coil ..................................................................................................................................................................... ✔ ✔ ✔
• Factory installed start kit ......................................................................................................................................................... 1-2 & 5 1-2 —
• Factory supplied charge ......................................................................................................................................................... R-410A R-22 R-22
AS
• Glossy corrosion resistant finish ............................................................................................................................................. ✔ ✔ ✔
• High pressure switch .............................................................................................................................................................. — ✔ ✔
• Internal high / low pressure & temperature protection ............................................................................................................. ✔ ✔ ✔
PH
• Liquid line filter drier - factory installed .................................................................................................................................... ✔ ✔ ✔
• Tarpaulin gray cabinet ............................................................................................................................................................ ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) .......................................................... ✔ ✔ ✔
• Extended warranties available ............................................................................................................................................ ✔ ✔ ✔
T
BAY24X045 ............. ID Fan Delay Relay Kit ............................................................................................................................. ✔ ✔ ✔
BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ................................................................................ 1½-2 1½-2 1½-5
OU
BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ............................................................................................. 2½-5 2½-5 —
BAYECMT001 ......... Extreme Condition Mounting Kit ............................................................................................................... ✔ ✔ ✔
BAYISLT101 ............ Rubber Isolators ....................................................................................................................................... ✔ ✔ ✔
BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ..................................................................................................... — — 2½-5
ED
BAYKSKT260 .......... Start Kit (Scroll Compressors) .................................................................................................................. 2½-4 2½-5 —
BAYKSKT261 .......... Start Kit (Base 1 & 2TTR1018, 024 only) (Reciprocating Compressors) ................................................... — — 1½-2
BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ............................................................................................. ✔ ✔ ✔
AS
BAYLEGS003 .......... 4" Extension (Black) ................................................................................................................................. ✔ ✔ ✔
BAYLOAM103 ......... Low Ambient Kit ....................................................................................................................................... — ✔ 2½-5
BAYLOAM104 ......... Low Ambient Kit with Start Kit .................................................................................................................. — — 1½-2
PH
BAYSDEN001 ......... Single Cylinder Compressor Enclosures .................................................................................................. — — 1½-2
BAYSDEN003 ......... Small Scroll Compressor Enclosures ........................................................................................................ — 2½-4 —
BAYSEAC001 ......... Seacoast Kit ............................................................................................................................................. ✔ ✔ ✔
XB12
PHASED OUT
2TTB2036A1000A
2TTB2042A1000A
2TTB2048A1000A
2TTB2060A1000A
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
36,000
42,000
48,000
60,000
.071
.077
.086
1
33
33
37
37
29
33
33
33
26
30
30
30
195
216
248
271
79
N/A
78
79
21
23
26
38
35
40
45
60
7
7
/8
/8
11/8
11/8
3
3
/8
/8
/8
/8
PHASED OUT
7 3
2TTB0036A1000A 200-230/1/60 36,000 .071 26 29 26 175 80 20 35 /8 /8
7 3
2TTB0042A1000A 200-230/1/60 42,000 .075 26 29 26 208 81 23 40 /8 /8
2TTB0048A1000A 200-230/1/60 48,000 .080 26 29 26 218 82 26 45 11/8 3
/8
2TTB0060A1000A 200-230/1/60 60,000 1 33 33 30 256 83 35 60 11/8 3
/8
XB10
3
/8
/4 5
1
/16
/4
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
XB10
XB 13 XB 12 XB 10 XB 10
Table SC-8-A — Features (2TTB3) (2TTB2) (2TTB0) (TTB)
T
• SEER’s up to ..................................................................................................................................................... 13.25 12.50 10.50 10.50
OU
• Climatuff™ compressor ................................................................................................................................... ✔ ✔ ✔ ✔
• Comfort”R”™ mode approved ......................................................................................................................... ✔ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ......................................................................................... ✔ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................. ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔
ED
• Spine Fin™ coil ................................................................................................................................................
• Compressor sump heat - factory installed .......................................................................................................... 5 — — —
• Factory supplied charge .................................................................................................................................... R-22 R-22 R-22 R-22
✔ ✔ ✔ ✔
AS
• Glossy corrosion resistant finish ........................................................................................................................
• Internal high / low pressure & temperature protection ........................................................................................ ✔ ✔ ✔ ✔
• Liquid line filter drier - factory installed ............................................................................................................... ✔ ✔ ✔ ✔
• Polyslate gray cabinet ....................................................................................................................................... ✔ ✔ ✔ ✔
PH
• Quick start kit - factory installed ......................................................................................................................... 1½-2½,3½-5 1½-2 — —
• 5 year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔ ✔
• Extended warranties available ....................................................................................................................... ✔ ✔ ✔ ✔
Table SC-8-B — Optional Accessories
AY28X079 ............... Evap. Defrost Control Kit ..................................................................................................... ✔ ✔ ✔ ✔
BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ........................................................... 1½-2½,3½-4 1½-2 2½-5 1-2
T
BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ........................................................................ 3 2½-5 — —
BAYECMT001 ......... Extreme Condition Mounting Kit .......................................................................................... ✔ ✔ ✔ —
OU
BAYISLT100 ............ Rubber Isolators (012, 018 & 024 only) ............................................................................... — — — ✔
BAYISLT101 ............ Rubber Isolators .................................................................................................................. ✔ ✔ ✔ —
BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ................................................................................ — — 2½-5 —
BAYKSKT260 .......... Start Kit (Scroll Compressors) ............................................................................................. 3 2½-5 — —
ED
BAYKSKT261 .......... Start Kit (18" only - TTB012,018 & 024) (Reciprocating Compressors) ................................ — — — 1-2
BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ........................................................................ ✔ ✔ ✔ —
BAYLEGS003 .......... 4" Extension (Black) ............................................................................................................ ✔ ✔ ✔ —
AS
BAYLOAM103 ......... Low Ambient Kit .................................................................................................................. ✔ ✔ ✔ —
BAYLOAM104 ......... Low Ambient Control Kit ...................................................................................................... — — — ✔
BAYSDEN001 ......... Single Cylinder Compressor Enclosures ............................................................................. 1½-2½ 1½-2 2½-3 1-2
PH
BAYSDEN002 ......... Two Cylinder Compressor Enclosures ................................................................................. — — 3½-5 —
BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................... 3 2½-4 — —
BAYSDEN004 ......... Large Scroll Compressor Enclosures .................................................................................. 5 5 — —
BAYSEAC001 ......... Seacoast Kit ........................................................................................................................ ✔ ✔ ✔ —
Table SC-8-C — Comfort Controls
AY28X092 ............... Heat/Cool ( Horiz.) Therm. .................................................................................................. ✔ ✔ ✔
BAYSTAT304 .......... Cooling Only w/ Fan Switch ................................................................................................. ✔ ✔ ✔
BAYSTAT305 .......... Heat/Cool ( Vertical ) Therm. ............................................................................................... ✔
✔
✔
✔T ✔
✔
OU
TAYASCT501A56 .. Anti-Short Cycle Timer ........................................................................................................
Zone Sensors Section
✔ ✔ ✔
See Comfort Controls/
3
2TTA3 2TTA3030A4000A 460/3/60 30,000 TXV-NB 33 33 30 225 78 5 15 /4 5/16
7 3
2TTA3036A4000A 460/3/60 36,000 TXV-NB 33 33 30 219 76 7 15 /8 /8
7 3
2TTA3042A4000A 460/3/60 42,000 TXV-NB 33 37 34 246 79 7 15 /8 /8
2TTA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 305 79 9 15 1 1/8 3/8
2TTA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 293 79 10 15 1 1/8 3/8
2TTA2
PHASED OUT
2TTA2030A4000A
2TTA2036A4000A
2TTA2042B4000A
2TTA2048A4000A
460/3/60
460/3/60
460/3/60
460/3/60
30,000
36,000
42,000
48,000
.065
.071
.077
.086
29
33
33
37
29
29
33
33
26
26
30
30
180
191
212
241
79
79
79
78
6
8
8
10
15
15
15
15
3
7
/4 5/16
/8
/8
3
3
/8
/8
11/8 3/8
2TTA2060A4000A 460/3/60 60,000 1 37 33 30 258 79 12 20 11/8 3/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
PHASED OUT
• SEER's up to .................................................................................................................................................................. 11.75 14.50 12.50
• Climatuff™ compressor ................................................................................................................................................ ✔ ✔ ✔
• Comfort”R”™ mode approved ...................................................................................................................................... ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ............................................... ✔ ✔ ✔
• Spine Fin™ coil ............................................................................................................................................................. ✔ ✔ ✔
• Compressor sump heat - factory installed ....................................................................................................................... 2½-6 2½-5 2½-5
• Factory supplied charge ................................................................................................................................................. R-22 R-22 R-22
• Glossy corrosion resistant finish ..................................................................................................................................... ✔ ✔ ✔
• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔
• Low pressure switch ....................................................................................................................................................... ✔ ✔ —
• PolySlate gray cabinet .................................................................................................................................................... ✔ ✔ ✔
• 5-year limited warranty on compressor, and 1 year on coil and parts (Commercial) ....................................................... ✔ ✔ ✔
• 5-year limited warranty on compressor, coil and 1 year on parts (Residential) ................................................................ ✔ ✔ ✔
• Extended warranties available .................................................................................................................................... ✔ ✔ ✔
PHASED OUT
AY28X079 .................................... Evaporator Defrost Control .......................................................................................... ✔ ✔ ✔
BAYECMT001 .............................. Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔
BAYISLT101 ................................. Rubber Isolators ........................................................................................................... ✔ ✔ ✔
BAYLEGS002 ............................... Snow Legs - Base and Cap 6" High (Black) ................................................................. ✔ ✔ ✔
BAYLEGS003 ............................... 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔
BAYLOAM103 .............................. Electronic Head Pressure Control ................................................................................ ✔ ✔ ✔
BAYSDEN001 .............................. Single Cylinder Compressor Enclosures ...................................................................... 2½-3 2½ —
BAYSDEN002 .............................. Two Cylinder Compressor Enclosures ......................................................................... 3½-5 3½-4 —
BAYSDEN003 .............................. Small Scroll Compressor Enclosures ........................................................................... — 3 2½-4
BAYSDEN004 .............................. Large Scroll Compressor Enclosures ........................................................................... 6 5 5
BAYSEAC001 .............................. Seacoast Kit ................................................................................................................. ✔ ✔ ✔
TAYASCT501A12 ...................... Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔
PHASED OUT
TAYSTAT241 ............................... Manual 2 Stg Htg/1 Clg ................................................................................................ ✔
TAYSTAT250B ............................. Outdoor Thermostat ..................................................................................................... ✔
TAYSTAT300C ............................ XT300C Prog.,7 Day,A/M,1Htg/1Clg ............................................................................ ✔
Zone Sensors Section
Table SC-14-A — TTA Split System Cooling — Dual Manifolded Compressors with Single Refrigerant Circuits
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.
TTA120C300G — 208-230/3/60 126,000 39 38 51 SPR 492 8.8 49.4 60 13/8 1
/2
TTA120C30SG Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30RG ReliaTel™, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30TG ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30UG ReliaTel™, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30WG ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492
Anti Short Cycle Timer (ASCT) Function — Provides a three (3) Low Ambient Start Timer (LAST) Function — Bypasses low
minute minimum “ON” time and a three (3) minute minimum “OFF” time pressure control when a compressor starts, eliminating nuisance
for compressors, enhances compressor reliability by ensuring proper oil compressor lock outs. Standard
return. Standard
Lower Installation Cost — Using a standard Zone Sensor Module
Built In Fan Delay Relay (FDR) Function — Provides custom indoor (ZSM), control voltage wiring may be run up to five (5) times further
fan timing sequences for the different types of equipment, enhancing than any electromechanical system, with no increase in wire gauge.
efficiency and reliability. Standard Example: Electromechanical System –
30 feet maximum using 22 gauge wire. Micro Control System – 150
Built In Night Set Back and Unoccupied Functions1 — When using feet using 22 gauge wire. Standard
a standard dual setpoint/auto change over Zone Sensor Module (ZSM),
this function is enabled by applying a short across terminal J6-11 and On Board Diagnostics1 — Assist with equipment troubleshooting, if
J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint a problem occurrence should take place. Standard
back a minimum of 7°F, and forces fan operation to automatic.
(requires time clock accessory or field supplied/installed switch or Remote Sensing1 — All standard Zone Sensor Modules
contacts). (ZSMs) have remote sensing capabilities, typically achieved by using
an expensive program-mable thermostat and remote sensor with
Built In “TEST” Mode — Aids in quick verification of system electromechanical equipment. Accessory (requires use of remote
and control operation, exercises both hardware and software sensor).
(no special tools required). Standard
Space Temperature Averaging1 — All standard Zone Sensor
Built In Unoccupied Mode1 — When using a standard single Modules (ZSMs) have space temperature averaging capabilities,
setpoint/manual change over Zone Sensor Module (ZSM), this function typically achieved by using an expensive programmable thermostat
is enabled by applying a short across terminal J6-11 and J6-12. Forces and minimum of four (4) remote sensors with electromechanical
fan operation to automatic. (requires time clock accessory or field equipment. Averaging with ReliaTel™ can be achieved with two
supplied/installed switch or contacts.) (2) sensors.
Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Time Delay Relay (TDR) Function — Provides an incremental
Proportional – sets corrective action proportional to deviation staging delay between compressors, minimizes equipment current
from setpoint. Integral – fine tunes the rate of corrective action inrush and consumption by keeping compressors from starting
proportional to the error (results in superior space temperature control). simultaneously. Standard
Standard
Low Pressure and High Pressure Compressor Lockout — 3 trips
Increased Reliability — Fewer components (moving electro- will lockout control.
mechanical parts), less likelihood of equipment down time or
failure. Standard
Integral Electric Heat Staging1 — Stages electric heaters “OFF” and
“ON”, eliminating the use of outdated sequencers. Standard
Intelligent Fallback1 — A built in Default Control provides adaptive
operation, which allows the equipment to continue
to operate, providing comfort in the event of certain component failures.
Also, allows emergency operation without a Zone Sensor Module
(ZSM). Standard
Table SH-1-A — XL19i Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Uncrated Shipping Line Size
Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.
7 3
2TWZ9030B1000A 200/230/1/60 30,000 TXV-NB 50 37 34 443 74 19 30 /8 /8
7 3
2TWZ9036B1000A 200/230/1/60 36,000 TXV-NB 50 37 34 440 74 22 36 /8 /8
2TWZ9048B1000A 200/230/1/60 48,000 TXV-NB 50 37 34 448 74 25 40 11/8 3
/8
2TWZ9060B1000A 200/230/1/60 60,000 TXV-NB 50 37 34 455 74 37 60 11/8 3
/8
Note: Because of limited capabilities, please refer to product data for approved combinations.
XL19i
Table SH-1-B — XL16i Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Uncrated Shipping Line Size
Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 5
4TWX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 260 72 12 20 /8 /16
3 3
4TWX6036B1000A 230/1/60 36,000 TXV-NB 46 37 34 305 71 24 40 /4 /8
7 3
4TWX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 320 74 29 50 /8 /8
7 3
4TWX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 362 74 35 60 /8 /8
XL16i
Table SC-1-C — XL15i Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TWX5024A1000A 208/230/1/60 24,000 TXV-NB 42 37 34 273 74 14 20 /4 /16
3 5
2TWX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 290 71 20 30 /4 /16
7 3
2TWX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 304 74 20 30 /8 /8
7 3
2TWX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 314 72 23 35 /8 /8
2TWX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 342 74 26 40 11/8 3
/8
XL15i
Table SH-1-D — XL14i Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 242 71 8 15 /8 /4
3 5
2TWX4024B1000A 200/230/1/60 24,000 TXV-NB 44 33 30 256 74 11 15 /4 /16
3 5
2TWX4030B1000A 208/230/1/60 30,000 TXV-NB 42 37 34 275 73 18 30 /4 /16
7 3
2TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 294 74 21 35 /8 /8
7 3
2TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 309 74 24 40 /8 /8
2TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 313 74 28 45 11/8 3
/8
2TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 340 74 34 50 11/8 3
/8
XL14i
Table SH-1-E — XL14i Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 224 74 10 15 /2 /4
5 5
4TWX4024B1000A 200/230/1/60 24,000 TXV-NB 48 33 30 239 74 13 20 /8 /16
3 5
4TWX4030B1000A 208/230/1/60 30,000 TXV-NB 48 33 30 242 71 20 30 /4 /16
3 3
4TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 259 72 21 35 /4 /8
3 3
4TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 274 74 25 40 /4 /8
7 3
4TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 280 74 30 50 /8 /8
7 3
XL14i 4TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 318 74 36 60 /8 /8
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
Table SH-3-C — XR13 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWR3018A1000A 200-230/1/60 18,000 TXV-NB 33 29 26 202 73 8 15 /8 /4
3 5
2TWR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 205 76 12 20 /4 /16
3
2TWR3030A1000A 200-230/1/60 30,000 TXV-NB 37 33 30 242 76 13 20 /4 5/16
7 3
2TWR3036A1000A 200-230/1/60 36,000 TXV-NB 37 37 34 292 76 19 30 /8 /8
7 3
2TWR3042A1000A 200-230/1/60 42,000 TXV-NB 41 37 34 309 78 21 35 /8 /8
2TWR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 315 76 25 40 1 1/8 3/8
XR13
2TWR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 321 73 32 50 1 1/8 3/8
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
PHASED OUT
3 5
4TWR2030A1000A 208/230/1/60 30,000 .059 33 33 30 234 74 20 30 /4 /16
3 3
4TWR2036A1000A 208/230/1/60 36,000 .063 41 33 30 257 77 21 35 /4 /8
3 3
4TWR2042A1000A 208/230/1/60 42,000 .069 41 33 30 262 79 26 45 /4 /8
XR12 4TWR2048A1000A 208/230/1/60 48,000 .075 33 37 34 271 79 30 50 7
/8 3
/8
4TWR2060A1000A 208/230/1/60 60,000 1 41 37 34 302 81 36 60 7
/8 3
/8
PHASED OUT
3 5
2TWR2030B1000A 208/230/1/60 30,000 .065 29 29 26 187 99 18 30 /4 /16
7 3
2TWR2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 /8 /8
7 3
2TWR2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 /8 /8
XR12 2TWR2048A1000B 208/230/1/60 48,000 .086 37 33 30 256 99 26 45 11/8 3
/8
2TWR2060A1000A 208/230/1/60 60,000 1 41 37 34 316 80 37 60 11/8 3
/8
Table SH-5-C — XR11 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWR1018A1000A 200/230/1/60 18,000 0.049 26 29 26 168 77 10 15 /8 /4
3 5
2TWR1024A1000A 200/230/1/60 24,000 0.057 26 29 26 176 77 15 25 /4 /16
PHASED OUT
3 5
2TWR1030A1000A 200/230/1/60 30,000 0.069 29 29 26 187 79 18 30 /4 /16
7 3
2TWR1036A1000A 200/230/1/60 36,000 0.069 29 29 26 190 79 21 35 /8 /8
7 3
2TWR1042A1000A 200/230/1/60 42,000 0.077 33 33 30 253 79 23 40 /8 /8
XR11 2TWR1048A1000A 200/230/1/60 48,000 0.083 33 33 30 259 80 30 50 11/8 3
/8
2TWR1060A1000A 200/230/1/60 60,000 1 33 37 34 292 81 34 50 11/8 3
/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
T
• SEER’s up to .................................................................................................................................................................. 13.00 13.00 11.50
• HSPF’s up to .................................................................................................................................................................. 9.25 10.15 8.50
OU
• Climatuff™ compressor ................................................................................................................................................ ✔ ✔ ✔
• Comfort”R”™ mode approved ...................................................................................................................................... ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ............................................... ✔ ✔ ✔
ED
• Spine Fin™ coil ............................................................................................................................................................. ✔ ✔ ✔
• Factory installed start kit ................................................................................................................................................. 1-2 & 5 1-2 —
• Factory supplied charge ................................................................................................................................................. R-410A R-22 R-22
AS
• Glossy corrosion resistant finish ..................................................................................................................................... ✔ ✔ ✔
• High pressure switch ...................................................................................................................................................... ✔ — —
• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔
PH
• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔
• Tarpaulin gray cabinet .................................................................................................................................................... ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) .................................................. ✔ ✔ ✔
• Extended warranties available ........................................................................................................................................ ✔ ✔ ✔
T
BAY24X045 ............. ID Fan Delay Relay Kit .....................................................................................................................
BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ........................................................................ 1½-2 1½-2 1½-5
OU
BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ..................................................................................... 2½-5 2½-5 —
BAYECMT001 ......... Extreme Condition Mounting Kit ....................................................................................................... ✔ ✔ ✔
BAYISLT101 ............ Rubber Isolators ............................................................................................................................... ✔ ✔ ✔
BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ............................................................................................. — — 2½-5
ED
BAYKSKT260 .......... Start Kit (Scroll Compressors) .......................................................................................................... 2½-4 2½-5 —
BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ..................................................................................... ✔ ✔ ✔
✔ ✔ ✔
AS
BAYLEGS003 .......... 4" Extension (Black) .........................................................................................................................
BAYLOAM103 ......... Low Ambient Kit ............................................................................................................................... — ✔ 2½-5
BAYLOAM104 ......... Low Ambient Kit with Start Kit .......................................................................................................... — — 1½-2
PH
BAYSDEN001 ......... Single Cylinder Compressor Enclosures .......................................................................................... — — 1½-2
BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................................ — 2½-4 —
BAYSEAC001 ......... Seacoast Kit ..................................................................................................................................... ✔ ✔ ✔
Table SH-7-A — XB13 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWB3018A1000A 200-230/1/60 17,000 TXV-NB 33 29 26 202 74 8 15 /8 /4
3 5
2TWB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 205 79 12 20 /4 /16
3
2TWB3030A1000A 200-230/1/60 28,500 TXV-NB 37 33 30 240 79 13 20 /4 5/16
7 3
2TWB3036A1000A 200-230/1/60 34,500 TXV-NB 37 37 34 291 79 19 30 /8 /8
7 3
2TWB3042A1000A 200-230/1/60 40,500 TXV-NB 41 37 34 308 80 21 35 /8 /8
XB13 2TWB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 312 78 25 40 1 1/8 3/8
2TWB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 318 79 32 50 1 1/8 3/8
Table SH-7-B — XB12 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWB2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 81 10 15 /8 /4
3 5
2TWB2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 82 13 20 /4 /16
PHASED OUT
3 5
2TWB2030A1000A 208/230/1/60 30,000 .065 29 29 26 187 79 18 30 /4 /16
7 3
2TWB2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 /8 /8
7 3
2TWB2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 /8 /8
2TWB2048A1000A 208/230/1/60 48,000 .086 37 33 30 256 79 26 45 11/8 3
/8
XB12 2TWB2060A1000A 208/230/1/60 60,000 1 41 37 34 316 80 37 60 11/8 3
/8
Table SH-7-C— XB10 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWB0012A1000A 200/230/1/60 12,000 .047 26 29 26 169 79 10 15 /8 /4
5 1
2TWB0018A1000A 200/230/1/60 18,000 .049 26 29 26 169 79 10 15 /8 /4
PHASED OUT
3 5
2TWB0024A1000A 200/230/1/60 24,000 .057 26 29 26 177 79 15 25 /4 /16
3 5
2TWB0030A1000A 200/230/1/60 30,000 .067 29 29 26 187 81 17 25 /4 /16
7 3
2TWB0036A1000A 200/230/1/60 36,000 .067 29 29 26 189 81 20 30 /8 /8
7 3
2TWB0042A1000A 200/230/1/60 42,000 .075 33 33 30 247 79 23 40 /8 /8
2TWB0048A1000A 200/230/1/60 48,000 .083 33 33 30 255 80 26 40 11/8 3
/8
XB10 2TWB0060A1000A 200/230/1/60 60,000 1 33 37 34 291 81 34 50 11/8 3
/8
1 Indoor Metering device TXV only.
T
• Climatuff™ compressor ....................................................................................................................................... ✔ ✔ ✔
OU
• Comfort”R”™ mode approved ............................................................................................................................ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................... ✔ ✔ ✔
• Spine Fin™ coil .................................................................................................................................................... ✔ ✔ ✔
ED
• Compressor sound enclosure ............................................................................................................................... 3-4 4-5 4-5
• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-2,4-5 1½-5
• Factory supplied charge ........................................................................................................................................ R-22 R-22 R-22
AS
• Glossy corrosion resistant finish ........................................................................................................................... ✔ ✔ ✔
• Low pressure switch ............................................................................................................................................. ✔ — —
• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔
PH
• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔
• PolySlate gray cabinet .......................................................................................................................................... ✔ ✔ ✔
• Quick start kit - factory installed ............................................................................................................................ 1½-5 1½-2,5 —
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔
• Extended warranties available .............................................................................................................................. ✔ ✔ ✔
OUT
BAYCCHT301 ........ Crankcase Heater Kit (Scroll Compressors) ............................................................................. — 2½-3½ —
BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔
BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔
BAYKSKT257 ........ Start Kit (Reciprocating Compressors) ..................................................................................... — — 1-5
BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. — 2½-4 —
SED
BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ............................................................................. ✔ ✔ ✔
BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔
BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... ✔ ✔ ✔
BAYSDEN001 ........ Single Cylinder Compressor Enclosures .................................................................................. 1½-2 1-3 ?
PHA
BAYSDEN002 ........ Two Cylinder Compressor Enclosures ..................................................................................... — 3½ ?
BAYSDEN003 ........ Small Scroll Compressor Enclosures ....................................................................................... 2½ -— ?
BAYSDEN004 ........ Large Scroll Compressor Enclosures ....................................................................................... 5 — ?
BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔
3 5
2TWA0030A4000A 460/3/60 30,000 .069 29 29 26 193 82 7 15 /4 /16
7 3
2TWA0036A4000A 460/3/60 36,000 .069 29 29 26 192 80 7 15 /8 /8
7 3
2TWA0042A4000A 460/3/60 42,000 .077 33 33 30 250 81 9 15 /8 /8
2TWA0048A4000A 460/3/60 48,000 .083 33 33 30 254 81 10 15 11/8 3
/8
2TWA0060A4000A 460/3/60 60,000 1 33 37 34 289 84 12 20 11/8 3
/8
2TWA0072A4000A 460/3/60 72,000 1 41 37 34 327 81 14 20 11/8 3
/8
PHASED OUT
2TWA2060A3000A 208-230/3/60 60,000 1 41 37 34 303 80 23 40 11/8 3
/8
2TWA2 3 5
2TWA2030A4000A 460/3/60 30,000 .065 29 29 26 188 79 6 15 /4 /16
7 3
2TWA2036A4000A 460/3/60 36,000 .071 33 33 30 228 77 7 15 /8 /8
7 3
2TWA2042A4000A 460/3/60 42,000 .077 33 33 30 224 79 8 15 /8 /8
2TWA2048A4000A 460/3/60 48,000 .086 37 33 30 250 79 10 15 11/8 3
/8
2TWA2060A4000A 460/3/60 60,000 1 41 37 34 303 80 12 20 11/8 3
/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.
PHASED OUT
• Climatuff™ compressor ..................................................................................................................................... ✔ ✔ ✔
• Comfort”R”™ mode approved .......................................................................................................................... ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof .......................................................................................... ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................. ✔ ✔ ✔
• Spine Fin™ coil .................................................................................................................................................. ✔ ✔ ✔
• Compressor sump heat - factory installed ........................................................................................................... 2½-6 2½-5 2½-5
• Factory supplied charge ...................................................................................................................................... R-22 R-22 R-22
• Glossy corrosion resistant finish ......................................................................................................................... ✔ ✔ ✔
• Internal high / low pressure & temperature protection ......................................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed ................................................................................................................ ✔ ✔ ✔
• Low pressure switch ........................................................................................................................................... ✔ ✔ ✔
• PolySlate gray cabinet ........................................................................................................................................ ✔ ✔ ✔
• 5-year limited warranty on compressor, and 1 year on coil and parts (Commercial) ........................................... ✔ ✔ ✔
• 5-year limited warranty on compressor, coil and 1 year on parts (Residential) ................................................... ✔ ✔ ✔
• Extended warranties available ............................................................................................................................ ✔ ✔ ✔
PHASED OUT
BAYECMT001 ................ Extreme Condition Mounting Kit ..................................................................................... ✔ ✔ ✔
BAYISLT101 .................. Rubber Isolators ............................................................................................................. ✔ ✔ ✔
BAYLEGS002 ................ Snow Legs - Base and Cap 6" High (Black) ................................................................... ✔ ✔ ✔
BAYLEGS003 ................ 4" Extension (Black) ....................................................................................................... ✔ ✔ ✔
BAYLOAM103 ................ Electronic Head Pressure Control .................................................................................. ✔ ✔ ✔
BAYSDEN001 ................ Single Cylinder Compressor Enclosures ........................................................................ 2½-3 2½ —
BAYSDEN002 ................ Two Cylinder Compressor Enclosures ........................................................................... 3½-5 3-4 —
BAYSDEN003 ................ Small Scroll Compressor Enclosures ............................................................................. — — 2½-4
BAYSDEN004 ................ Large Scroll Compressor Enclosures ............................................................................. 6 5 5
BAYSEAC001 ................ Seacoast Kit ................................................................................................................... ✔ ✔ ✔
TAYASCT501A12 ........ Anti-Short Cycle Timer ................................................................................................... ✔ ✔ ✔
PHASED OUT
TAYSTAT241 ................. Manual 2 Stg Htg/1 Clg .................................................................................................. ✔
TAYSTAT250B .............. Outdoor Thermostat ....................................................................................................... ✔
TAYSTAT300C ............. XT300C Prog.,7 Day,A/M,1Htg/1Clg .............................................................................. ✔
Zone Sensors Section
Table SH-11-A — Optional factory installed Black Epoxy Coil for corrosive resistance.
Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.
TWA090A30SF Epoxy Coil 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 13/8 1
/2
TWA120A30SF Epoxy Coil 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 13/8 1
/2
TWA090A40SF Epoxy Coil 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 13/8 1
/2
TWA120A40SF Epoxy Coil 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 13/8 1
/2
TWA090AW0SF Epoxy Coil 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 20 13/8 1
/2
TWA120AW0SF Epoxy Coil 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 25 13/8 1
/2
Table SH-11-B — Optional factory installed Black Epoxy Coil for corrosive resistance.
Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.
TWA180B30SF Epoxy Coil 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 13/8 1
/2
TWA240B30SF Epoxy Coil 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 13/8 1
/2
TWA180B40SF Epoxy Coil 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 13/8 1
/2
TWA240B40SF Epoxy Coil 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 13/8 1
/2
TWA180BW0SF Epoxy Coil 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 13/8 1
/2
TWA240BW0SF Epoxy Coil 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 13/8 1
/2
1 Sound Rating shown is tested in accordance with ARI standard 270 or 370.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
For complete equipment / combination
selections and installation instructions, please SH-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Three Phase – 7½ through 20 Tons
Trane Profit-ability
Sell-ability
Superior performance and appearance
4-speed fan motor
Air-TiteTM cabinet
Precision engineering
Sound reduction
Matched systems
TRANE LIMITED WARRANTY
5-year functional parts
Install-ability
6-way convertibility
Tonnage 1.5 to 5
Recessed screws
External drain connections
Service-ability
Easy-access control box
Quick filter change with standard filters
External refrigerant components
Easy coil cleaning
Performance-ability QUIET AND HIGHLY EFFICIENT. DESIGNED WITH YOUR CUSTOMER IN MIND.
High efficiency The 2TEH air handler is the right choice for customers is among the quietest units we make. It has a high
400 CFM/ton nominal airflow looking to maximize comfort and efficiency. Ideal for new efficiency blower motor and our unique VorticaTM blower
Thermostatic expansion valve home builders or as a replacement unit for discerning design—all in an attractive, smaller-sized package that
Rely-ability customers, the 2TEH has a 4-speed indoor blower meets or beats the competition for reliability. And that
Best reliability distributing 400 CFM/ton nominal air flow for even, should yield some reliable profits for you.
Quiet internal check valve consistent comfort every month of the year. The 2TEH
Reliable performance Better indoor air Comfort control Enhanced comfort Efficient operation
Precision engineering, design Add a TRANE CleanEffects air
TM
Give your customers better Delivers quiet, even, consistent Increased efficiency
innovation and rigorous testing for cleaner and remove up to 99.98% comfort control with a Trane digital comfort all year round. may substantially lower
reliable, long-lasting performance of airborne allergens from the or programmable thermostat. customers’ utility costs.
and durability. filtered air for a cleaner, more
comfortable home.
10
and are shown for illustration purposes only.
3 “No Leak” base pan Standard off-the-shelf filters located behind one
Rust-resistant, polycarbonate drain pan. Fully easy-to-remove door for quick and convenient
4 sloped to put an end to standing water. filter change.
trane.com
© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. 2TEHAH-01 11/05
Airflow
Airflow
Airflow
Primary Condensate
Vertical Downflow
One-Step Conversion
from Horizontal left
1 Duct Flange – Allows flush fit for 3/4", 1" or 1 1/2" duct insulation heat transfer, and lower power bills.
2 Liner/Flange Seal – Exclusive Duct Flange Thermal 8 Filter Door – "Filter" is stamped on the panel, and includes
Break/Seal and double wall construction to reduce two captive screws with easy grip knobs.
cabinet loss and sweating. 9 Insulation on Center Bar – Exclusive center bar insulation
3 1" Foil Faced Insulation – Thicker foil faced insulation for reduced cabinet loss, sweating and lower power bills.
for reduced cabinet loss, sweating and lower power bills. 0 Door Gasket – Exclusive formed gasket (similar to car door
4 Enclosed Control Box – Totally enclosed control box gasket) to reduce air infiltration and heat transfer and lower
with transformer inside to improve component life, unit power bills.
durability and reliability. q Air-TiteTM Circuit Breaker Door – Easy access to breakers
5 Corrosion Resistant Screws – Exclusive “WeatherguardTM” with positive air seal.
coated screws to maintain the quality appearance of the
unit for the life of the product. The SEER test for system efficiency places the air handler in
6 Coupling Panel Insulation – Exclusive “No Burn” refrigerant the ambient return air stream (80°F). If your air handler is to
coupling panel with thicker insulation for reduced heat loss. be in an unconditioned/severe climatic location, you should
consider the advantages of the “Air-TiteTM” model air handler.
7 Filter Door Seal – Improved door seal for reduced air infiltration,
For complete equipment / combination
Effective 1/1/06 AH-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons
Table AH-3-B — R-22 Convertible, Dual Circuit, Variable Speed with Comfort-RTM Enhanced Mode Option (200/230/1/60)
TWE062E13FB3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 ¾ 3
/8
Table AH-3-D —R-410A Convertible, Dual Circuit, Variable Speed with Comfort-R™ Enhanced Mode Option (200/230/1/60)
4TEE3F62A1000A3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.22 20x25x1 ¾ 3
/8
• 13.0 - 14.0 SEER • Versatile duct flange - allows flush fit 3/4",
• High Efficiency direct drive motor 1", or 1.5" duct insulation
• Ships for vertical upflow and horizontal right • Filter panel stamped with word "filter"
applications from factory • 200/230 volt primary & 24 volt secondary
• Six- way convertibility-horizontal (left & transformer
right) upflow, downflow • Low voltage wire nut connections
• “1-man” installation opportunity • Insulated cabinet
• Electrical, refrigerant, condensate & blower • External access to heater electrical
access convertible to either side disconnects
• Compact 21" depth for easy • Polarized plugs for making electrical
installation connections from air handler control box to
• Corrosion resistant galvanized metal with heaters
attractive finish • Approved for modular or manufactured
• Superior humidity performance homes
11/2 through 5 Tons
• Enhanced internally finned coil tubes • Optional extended warranties
Convertible High Efficiency
Air Handlers
2TEH3F18 & 24B will accommodate 10 & 15 kW Strip Heat - (BAYHTR1300 series only) in March, 2006.
1 1
4TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /2 /4
5 5
4TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /16
3 5
4TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 3
4TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /8
3 3
4TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /4 /8
7 3
4TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /8 /8
7 3
4TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
7 3
4TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 /8 /8
• Exclusive easy to clean coil and drain pan • Durable, glass-filled composite - Never rust,
• Convertible upflow to horizontal left (no no leak drain pan
tools required) (matches installed units) • Maximum depth 21" - fits pull-down
• Designed to use "off the shelf" staircase
standard size replaceable fiberglass • Exclusive maximum width 23.5" - fits 2-ft.
filters wide door all sizes
• Easy to remove filters and blowers for easy • External access to electrical disconnects
cleaning and replacement • Direct drive motor
• Expanded application fit with narrow • Filter panel stamped with word "filter"
cabinet profile • Expansion valve (non-bleed TXV)
• Easy access electrical controls and hook- standard on all models
up • Polarized plugs for easy hook-up to electric
• Attractive enamel finish heaters
• R 4.2 - 1" insulation • 200/230 volt primary and 24 volt secondary
11/2 through 4 Tons • Versatile duct flange - allows flush fit with transformer
3/4", 1" or 1.5" duct insulation • Approved for modular or manufactured
• Air-Tite™ cabinet - low leak by design homes
• IAQ (Indoor Air Quality) sloped/free • Optional extended warranties
draining pan (no standing water)
• Shipped in vertical upflow, bottom return • Filter rack with throw away filter
with front access & convertible to vertical • Easy access electrical controls and
upflow front return hook-up
• Variable speed ECM motor • 200/230 volt primary and 24 volt secondary
(2/4TFE Models) transformer
• Enhanced Comfort-R™ (2/4TFE Models) • Multi-speed blower (2TFB Models)
• Soft start - fan speed is ramped up • Direct drive motor (2TFB Models)
gradually to reduce sound and draft • Factory installed electric heaters
(2/4TFE Models) • Factory installed service disconnect
• Low voltage terminal board • Internally enhanced finned coil tubing
(2/4TFE Models) • Primary and secondary drain connections
• Air-Tite™ cabinet - low leakage by design • Approved for modular or manufactured
• Attractive enamel finish homes
• R 4.2-1” insulation • Optional extended warranties
• Exclusive easy clean coil and drain pan • Five year limited parts warranty
• Easy to remove filters and blowers for easy
11/2 through 21/2 Tons cleaning and replacement
Table AH-9-B Heaters For TWE-C/D; TWE-P;TWE-E;TWG; 4TEE;2/4TEP, 2/4 TEC, 2TGB
Heater Capacity Capacity Heater Amps Contains
Model @ 240 Volts @ 208 Volts Rated Control per Circuit Circuit
Number kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt Breakers
BAYHTR1405000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 No
BAYHTR1405BRKB 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 Yes
BAYHTR1405PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 No
BAYHTR1408000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 No
BAYHTR1408BRKB 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 Yes
BAYHTR1408PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 No
BAYHTR1410000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 No
BAYHTR1410BRKB 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 Yes
BAYHTR1410PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 No
BAYHTR1415BRKB 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 Yes
BAYHTR1419BRKB 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 Yes
BAYHTR1425BRKB 24.96 85,200 18.73 63,900 208/240/1/60 3 38.1/34.6/17.31 44/40/201 Yes
Three Phase
BAYHTR3410000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 No
BAYHTR3415000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No
MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX
AIR HEATER MODEL NUMBER BAYHTR—
HANDLER
MODEL 1405 000 1408 000 1410 000
BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRK
NUMBER PDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW
4.80kW 7.68kW 3410 000
9.60kW
NUMBER OF 1 2 2 2 2 4 5
HEATER RACKS
NUMBER OF 1 1 1 2 1 2 3
CIRCUITS
TWE031E 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —
TWE037E 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —
TWE040E 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400
TWE049E 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600
TWE062E 900/1500 900/1500 900/1500 1200/1800 1200/1800 1200/1800 1200/1800
TWE065E 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/1800
4TEE3F31A 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —
4TEE3F37A 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —
4TEE3F40A 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400
4TEE3F49A 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600
4TEE3F65A 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/1800
2/4TEC3F18A L/L L/M L/M — — — —
2/4TEC3F24A L/L L/L L/L L/M L/M — —
2/4TEC3F30A L/L L/L L/L L/M L/M — —
2/4TEC3F36A L/L L/L L/L L/H L/H L/H —
(Example: L=Low, M=Medium, H=High Speed) 2/4TEC3F42A L/L L/L L/L L/PS L/PS L/H —
PS = Minimum speed tap varies based on air 2/4TEC3F48A L/L L/L L/L L/PS L/PS L/PS —
handler installation position.
AS = Heater application is affected based on
2/4TEC3F60A L/L L/L L/L L/PS L/PS L/PS —
whether the outdoor unit is a heat pump 2TGB3F18A L/L L/M L/H N/A N/A N/A —
or cooling unit.
000 = Pigtails, BRK = Contains circuit
2TGB3F25A L/L L/M L/M L/H L/H N/A —
breakers, PDC = Contains Pull 2TGB3F30A L/L L/L L/L L/M L/M N/A —
Disconnect 2TGB3F36A L/L L/L L/L L/M L/M N/A —
* For heat pump applications, upflow position 2TGB3F42A L/L L/L L/L L/H L/H N/A
only minimum setting is 1200 2TGB3F48A L/L L/L L/L L/H L/H L/H —
1 Circuit 1/Circuit 2
2 Heater can be converted to single circuit power entry by using BAYSPEK140B. This kit allows a single power circuit to be
used with electric heaters that contain two (2) circuit breakers.
BAYSPEK140B to be used with BAYHTR1415BRKB/ BAYHTR1419BRKB only.
CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local
electrical codes.
For complete equipment / combination
selections and installation instructions, please AH-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Heaters for Split System and
Convertible Air Handlers
MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX
AIR HEATER MODEL NUMBER BAYHTR—
HANDLER
MODEL 1405 000 1408 000 1410 000
BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRK
NUMBER PDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW
4.80kW 7.68kW 3410 000
9.60kW
NUMBER OF 1 2 2 2 2 4 5
HEATER RACKS
NUMBER OF 1 1 1 2 1 2 3
CIRCUITS
TWE018P L/L L/M L/M — — — —
TWE024P L/L L/L L/L L/M L/M — —
TWE030P L/L L/L L/L L/M L/M — —
TWE036P L/L L/L L/L L/H L/H L/H —
TWE042P
TWE048P
TWE060P
PHASED OUT
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
PS
PS
PS
PS
PS
PS
L/H
L/H
L/H
—
L/H
L/H
TWE063P L/L L/L L/L PS PS L/H L/H
2TEP3F48B — L/L L/L L/L L/L — —
2TEP3F63B — L/L L/L PS PS — —
4TEP3F18A L/L L/M L/M — — — —
4TEP3F24A L/L L/L L/L L/M L/M — —
4TEP3F30A L/L L/L L/L L/M L/M — —
4TEP3F36A L/L L/L L/L L/H L/H L/H —
4TEP3F42A
4TEP3F48A
4TEP3F63A
PHASED OUT
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
PS
PS
PS
PS
PS
PS
L/H
L/H
L/H
—
L/H
L/H
4TEP3F48B — L/L L/L L/L L/L — —
4TEP3F63B — L/L L/L L/L L/L — —
TWE018C L/L L/M L/M — — — —
TWE024C L/L L/L L/L L/M L/M — —
TWE030C L/L L/L L/L L/M L/M — —
TWE036C L/L L/L L/L L/L L/L PS —
TWE042C
TWE048C
TWE060C/D
L/L
L/L
AS
PHASED OUT L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
AS
L/H
L/H
—
L/H
L/H
(Example: L=Low, M=Medium, H=High Speed)
PS = Minimum speed tap varies based on air TWG018A L/L L/M L/H — — — —
handler installation position. TWG025A L/L L/M L/M L/H L/H — —
AS = Heater application is affected based on TWG030A L/L L/L L/L L/M L/M — —
PHASED OUT
whether the outdoor unit is a heat pump
or cooling unit. TWG036/037A L/L L/L L/L L/M L/M — —
000 = Pigtails, BRK = Contains circuit TWG042A L/L L/L L/L L/H L/H — —
breakers, PDC = Contains Pull TWG048A L/L L/L L/L L/H L/H L/M —
Disconnect
* For heat pump applications, upflow position
TWG060A L/L L/L L/L L/L L/L L/M L/H
only minimum setting is 1200 CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local
electrical codes.
7
/8
/8
11/8
11/8
11/8
3
3
/8
/8
/8
/8
/8
TWE060P13FB(Air TiteTM) 58,000 TXV-NB 3 57.90x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
TWE063P130B3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
TWE063P13FB3(Air TiteTM) 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
2TEP3F48B1000B3(Air TiteTM) 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3
/8
2TEP3F63B1000B3(Air TiteTM) 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3
/8
PHASED OUT
3 5
4TEP3F30A1000A 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 3
4TEP3F36A1000A 36,000 TXV-NB 3 45 x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /8
3 3
4TEP3F42A1000A 42,000 TXV-NB 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /4 /8
7 3
4TEP3F48A1000A 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
7 3
4TEP3F63A1000A3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
7 3
4TEP3F48B1000B3 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 /8 /8
7 3
4TEP3F63B1000B3 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 /8 /8
PHASED OUT
BAYSPEK140A ............................ Single Power Entry Kit ................................... BAYHTR1415BRKAB, 1419BRKAB
TAYBASE100 ............................... Downflow Subbase ........................................ TWE042P/4TEP3F42P
TAYBASE101 ............................... Downflow Subbase ........................................ TWE018-36P/4TEP3F18-36P
TAYBASE102 ............................... Downflow Subbase ........................................ TWE048P-063P/2, 4TEP3F48-F63P
TAYPLNM1005 ............................ Pedestal Plenum Upflow ................................ TWE018-042P/2, 4TEP3F48-F42P
TAYPLNM101 ............................... Pedestal Plenum Upflow ................................ TWE048-063P/2, 4TEP3F48-F63P
1 Actual opening does not include flange.
4 Minimum Order 1 unit (1 unit = 50 pcs.)
2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.
5 For TWE018P-36P, 4TEP3F18A-36A, center on plenum for 2" difference in width.
3 Two piece cabinet.
** Required if no electric heat is used.
See Heater Tables on Pages AH-9
For complete equipment / combination
selections and installation instructions, please AH-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons
7
/8
/8
/8
/8
11/8
3
3
/8
/8
/8
/8
/8
TWE048C14FC(Air TiteTM) 48,000 .083 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3
/8
TWE060D150B 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3
/8
TWE060C15FD3(Air TiteTM) 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3
/8
PHASED OUT
BAY99X1235 ................................. Knockout Cover Plate* .................................... TWE018-060C/D
BAYSPEK140A .............................. Single Power Entry Kit .................................... BAYHTR1415BRKAB, 1419BRKAB
TAYBASE100 ................................. Downflow Subbase ......................................... TWE042-060C/D
TAYBASE101 ................................. Downflow Subbase ......................................... TWE018-036C
TAYPLNM1004 ............................. Pedestal Plenum Upflow ................................. TWE018-060C/D
1 Actual opening does not include flange.
2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.
3 Two piece cabinet.
4 For TWE018-036 center on plenum for 2" difference in width.
5 Minimum order 1 unit (1 unit = 50 pcs.).
* Required if no electric heat is used.
See Heater Tables on Pages AH-9
• Easy to clean coil and drain pan • Exclusive maximum width 231/2 inches – fits
• Convertible upflow to horizontal left, (no 2 foot wide door
tools required) (matches installed units) • Built-in time delay
• Designed to use “off the shelf” standard • Full line 11/2 – 5 tons
size replaceable fiberglass filters – • Direct drive motor
Industry Exclusive • Filter panel stamped with word “filter”
• Easy to remove filters and blowers for easy • AccuTronTM refrigerant control
cleaning and replacement • Expansion valve (Bleed TXV) standard on
• Expanded application fit with narrow 5-ton models
cabinet profile • Polarized plugs for easy hook-up to electric
• Easy access electrical controls and heaters
hook-up • 200/230 volt primary and 24 volt secondary
• Attractive enamel finish transformer
• R 4.2-1" foil face insulated cabinet • Electric heaters with breaker option on all
• Versatile duct flange – allows flush fit 3/4, 1 sizes
or 11/2 inch duct insulation • Approved for modular or manufactured
• Tight cabinet - low leak by design homes
• IAQ (Indoor Air Quality) sloped/free draining • 5 year limited parts residential warranty
pan, no standing water • 1 year limited parts commercial warranty
11/2 through 5 Tons • Durable, glass-filled Lexan – Never rust, no • Optional extended warranties
TWG leak drain pan
Convertible Air Handlers • Maximum depth 21 inches – fits pull-down
staircase
Table AH-13-A — Convertible (208-230/1/60)
Cooling
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
TWG018A140B 18,000 .049 3 43x16x21 108 14x12.12 or 13x11.12 14x18.22 14x20x1 /8 /4
3 5
TWG025A140B 24,000 .057 3 45.70x18x21 124 16x12.12 or 15 x11.12 16x18.22 16x20x1 /4 /16
PHASED OUT
3 5
TWG030A140B 30,000 .067 3 45.70x18x21 125 16x12.12 or 15 x11.12 16x18.22 16x20x1 /4 /16
7 3
TWG036A140B 36,000 .067 3 52x18x21 135 16x12.12 or 15 x11.12 16x18.22 16x20x1 /8 /8
7 3
TWG037A140B 37,000 .067 3 43x21.5x21 145 19.5x12.12 or 18.5 x11.12 19.5x18.22 20x20x1 /8 /8
7 3
TWG042A140B 42,000 .075 3 43x23.5x21 160 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 /8 /8
7 3
TWG048A140B 48,000 .083 3 48.25x23.5x21 185 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 /8 /8
7 3
TWG060A150B 58,000 TXV-B 3 57.25x23.5x21 205 21.5x12.12 or 20.5x11.12 21.5x18.22 22x20x1 /8 /8
1 Actual opening does not include flange.
2 Adjustable duct flange allows for a flush fit with 3/4, 1 or 11/2 inch insulation.
• Shipped in vertical upflow front return with • AccuTronTM refrigerant control (2TFB)
front access & convertible to vertical upflow • Standard expansion valve kits are internally
bottom return mounted (2TFB)
• Tight cabinet - low leakage by design • Factory installed service disconnect
• Attractive enamel finish • Internally enhanced finned coil tubing
• R 4.2 – 1” insulation • Primary and secondary drain connections
• Exclusive easy clean coil and drain pan • Approved for modular or manufactured
• Easy to remove filters and blowers for easy homes
cleaning and replacement • Variable speed ECM motor (2TFE)
• Filter rack with throw away filter • Enhanced Comfort-RTM (2TFE)
• Easy access electrical controls and hook – • Soft start – cycle-on speed is ramped up
up 200/230 volt primary and 24 volt gradually to reduce sound (2TFE)
secondary transformer • Low voltage terminal board (2TFE)
• Built-in indoor fan delay function for • Expansion valve refrigerant control (2TFE)
increased efficiency. No kit required • 5 year limited parts residential warranty
• Multi-speed blower (2TFB) • 1 year limited parts commercial warranty
• Direct drive motor (2TFB) • Optional extended warranties
11/2 through 3 Tons
• Factory installed electric heaters
Table AH-14-A — (200/230/1/60)
Cooling Bottom
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
2TFB4018A1D05A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /8 /4
5 1
2TFB4018A1D08A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /8 /4
5 1
2TFB4018A1D10A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /8 /4
3 5
2TFB4024A1D05A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
PHASED OUT
3 5
2TFB4024A1D08A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4024A1D10A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4030A1D05A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4030A1D08A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4030A1D10A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
7 3
2TFB4036A1D05A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 /8 /8
7 3
2TFB4036A1D08A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 /8 /8
7 3
2TFB4036A1D10A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 /8 /8
3
/4
/4
5
5
/16
/16
2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.
• New 11th Digit "E" model ReliaTel™ and • IAQ (Indoor Air Quality) sloped/free draining
electromechancial compatible. pan, no standing water
• Upflow convertible to horizontal 5 • Two inch filters factory installed on 15, 20
• Expansion valve factory installed ton units
• Check valves for heat pump applications • Supplemental heaters (electric, water,
• Belt drive blower steam) fits directly on unit discharge for low
• Factory installed motor, belt, sheaves, installation cost
contactor, low voltage terminal board • Single point power entry for reduced
• One inch filters on 5 to 10 ton units (rack electrical power installation cost
convertible for field supplied two inch) • Unit fully assembled to reduce field
• Captive screws remain on the panels installation costs
for service ease • Compact design with low service clearance
• Low voltage terminal board to reduce building requirements
5, 71/2, 10, 15, 20 Ton TWE • Drain Pan • Brazed refrigerant piping connections
• Factory Installed (EDC) Evaporator Defrost • Fan relay UL listed and CSA Certified
Convertible Air Handlers Control • Optional extended warranties
(Upflow or Horizontal Only)
Table AH-15-A — Single Circuit Coil
Shipping Max Fuse Size
Unit Power Supply Capacity Drive 4
Dimensions (in.)4 Weight or Max Circuit
Tons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* 3*
Breaker3
Single Phase
5 TWE060A100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 15
71/2 TWE090A100E1 208-230/1/60 90,000 TXV Belt 54 x48 x 26 388 8 15
10 TWE120A100E1 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15
Three Phase
5 TWE060A300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 15
5 TWE060A400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 15
5 TWE060AW00E 575/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 15
71/2 TWE090A300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 15
71/2 TWE090AW00E1 575/3/60 90,000 TXV Belt 54 x48 x 23 298 4 15
10 TWE120A300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 15
10 TWE120AW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 15
1
Table AH-16-A — Supplementary Heaters1
Model No. Power Supply kW Rating Used With
BAYHTRL106A 208/240/1/60 4.33/5.76 TWE060-120A1, TWE060-120B1
BAYHTRL112A 208/240/1/60 8.65/11.52 TWE060-120A1, TWE060-120B1
BAYHTRL117A 208/240/1/60 12.98/17.28 TWE060-120A1, TWE060-120B1
BAYHTRL123A 208/240/1/60 17.30/23.04 TWE060-120A1, TWE060-120B1
BAYHTRL129A 208/240/1/60 21.65/28.80 TWE090-120A1, TWE090-120B1
BAYHTRL305A 208/240/3/60 3.75/5.00 TWE060-120A3, TWE060-120B3
BAYHTRL310A 208/240/3/60 7.45/9.96 TWE060-120A3, TWE060-120B3
BAYHTRL315A 208/240/3/60 11.25/14.96 TWE060-120A3, TWE060-120B3
BAYHTRL325A 208/240/3/60 18.71/24.92 TWE060-120A3, TWE060-120B3
BAYHTRL335A 208/240/3/60 26.20/34.88 TWE090-120A3, TWE090-120B3
BAYHTRL405A 460/3/60 5.00 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL410A 460/3/60 9.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL415A 460/3/60 14.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL425A 460/3/60 24.92 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL435A 460/3/60 34.88 TWE090,120A32, TWE090-120B32
BAYHTRLW05A 575/3/60 5.00 TWE060AW, TWE090-120AW, TWE090-120BW
BAYHTRLW10A 575/3/60 9.96 TWE060AW, TWE090-120AW, TWE090-120BW
BAYHTRLW15A 575/3/60 14.96 TWE060AW, TWE090-120AW, TWE090-120BW
BAYHTRLW25A 575/3/60 24.92 TWE060-120AW
BAYHTRLW35A 575/3/60 34.88 TWE090,120AW
BAYHTRM310A 208/230/3/60 7.50/10.00 TWE180-240B3
BAYHTRM320A 208/230/3/60 14.96/19.92 TWE180-240B3
BAYHTRM330A 208/230/3/60 22.50/29.92 TWE180-240B3
BAYHTRM350A 208/230/3/60 37.42/49.84 TWE180-240B3
BAYHTRM410A 460/3/60 10.00 TWE180-240B4
BAYHTRM420A 460/3/60 19.92 TWE180-240B4
BAYHTRM430A 460/3/60 29.92 TWE180-240B4
BAYHTRM450A 460/3/60 49.84 TWE180-240B4
BAYHTRMW10A 575/3/60 10.00 TWE180-240BW
BAYHTRMW20A 575/3/60 19.92 TWE180-240BW
BAYHTRMW30A 575/3/60 29.92 TWE180-240BW
BAYHTRMW50A 575/3/60 49.84 TWE180-240BW
1 Air Handler with heater of same voltage is single circuit single point.
2 Field converted to 460/3/60.
Factory Supplied
Accessories
A Air Handler (TWE 5 – 20 Tons)
SB
I
I
RG
LA
TRANE
XT90
TRANE XT90 HIGH EFFICIENCY FURNACE
Trane Profit-ability
Sell-ability
Industry leader and brand reputation
Higher efficiency single-stage furnace
Greater reliability
Quieter operation
Install-ability
Air cleaner and humidifier leads
Upflow/horizontal left
Downflow/horizontal right
Left/right gas and electrical hookups
Direct-vent option
TRANE LIMITED WARRANTY
Lifetime heat exchanger
Service-ability 5-year functional parts
Quarter-turn blower door latches
on upflow models
Self-diagnostic controls
Common parts across family
Compatible with higher SEER
outdoor units
Performance-ability
4-speed, high efficiency motor
90% efficiency on gas
Insulated blower door and cabinet
save energy and reduce sound
Automotive-grade gaskets reduce
air sound and infiltration
Rely-ability MORE ENHANCED COMFORT, EXTRA-EFFICIENT PROFITS.
Each is factory tested before shipping The TRANE XT90 furnace provides a higher efficiency, construction and replacement. It’s easy to install
Silicon nitride igniter single-stage furnace option with a bonus of added and service. And can accommodate upgrades to higher
100% fresh air option reliability. Because it uses less electricity in both SEER outdoor units. Install it and provide an enhanced
Integrated furnace control
its heating and cooling operations, it will appeal to comfort experience that will make you and your
Aluminized heat exchanger
efficiency-minded customers for residential new customers more comfortable, too.
Multi-port in-shot burners
Reliable performance Better indoor air Comfort control Enhanced comfort Efficient operation
Precision engineering, design Add a TRANE CleanEffects TM
Give your customers better Intelligently designed to Designed with innovative
innovation and rigorous testing air filtration system to remove up to comfort control with a Trane deliver maximum comfort with technological touches throughout
for reliable, long-lasting 99.98% of airborne allergens from digital or programmable fuel efficiency. to provide the ultimate in energy
performance and durability. the filtered air for a cleaner, more thermostat. efficient operation that lowers
comfortable home. customers’ heating costs.
TRANE
XT90
TRANE XT90 HIGH EFFICIENCY FURNACE
1 High efficiency blower motor 6 Multi-port in-shot burners
9 Controlled by a built-in microcomputer and on-board Perfectly shape the flame cone for the maximum heat possible
relays. Fixed 45-second time delay controls the indoor while using less fuel. No service adjustment necessary.
2 8 blower in heating cycles. Blower off timing is adjustable
by presets, allowing you to customize comfort in the home. 7 Automotive-grade gaskets and insulated
2 Adaptive silicon nitride hot surface igniter blower compartment
6 10 Help reduce operating sound and air infiltration.
Prevents overheating, which results in a highly reliable ignition
system and longer service life. 8 Aluminized steel heat exchanger
Features and components may vary by model
and are shown for illustration purposes only.
trane.com
© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. XT90FURN-01 09/05
TRANE
XT80
TRANE XT80 HIGH EFFICIENCY FURNACE
Trane Profit-ability
Sell-ability
Industry leader and brand reputation
Higher efficiency single-stage furnace
Greater reliability
Quieter operation
Install-ability
Air cleaner and humidifier leads
Upflow/horizontal left or right
Downflow/horizontal left or right
Left/right gas and electrical hookups TRANE LIMITED WARRANTY
20-year heat exchanger
Service-ability 5-year functional parts
Quarter-turn blower door latches
on upflow models
Self-diagnostic controls
Common parts across family
Compatible with higher SEER
outdoor units
Performance-ability
4-speed high efficiency motor
80% efficiency on gas
Insulated blower door and cabinet
save energy and reduce sound
Automotive-grade gaskets reduce
air sound and infiltration
OUR NEW SINGLE-STAGE, HIGH EFFICIENCY XT80 FURNACE REALLY HEATS UP YOUR SALES.
Rely-ability With a high efficiency motor, the TRANE XT80 furnace service. It also can accommodate upgrades to higher
Each is factory tested before shipping
sets the stage for increased sales. It uses less SEER outdoor units. The XT80 furnace is a high
Silicon nitride igniter
electricity in both its heating and cooling operations, efficiency product that both you and your customers
Integrated furnace control
Aluminized heat exchanger so it’s very attractive for new residential construction can be comfortable with.
Multi-port in-shot burners and replacement. And it’s easy for you to install and
Reliable performance Better indoor air Comfort control Enhanced comfort Efficient operation
Precision engineering, design Add a TRANE CleanEffects air
TM
Give your customers better comfort Intelligently designed to Designed with innovative
innovation and rigorous testing filtration system to remove up to control with a Trane digital or deliver maximum comfort with technological touches throughout
for reliable, long-lasting 99.98% of airborne allergens from programmable thermostat. fuel efficiency. to provide the ultimate in energy
performance and durability. the filtered air for a cleaner, efficient operation.
more comfortable home.
TRANE
XT80
TRANE XT80 HIGH EFFICIENCY FURNACE
1 High efficiency blower motor 5 Easy-access doors
Controlled by a built-in microcomputer and on-board Quarter-turn dual door latches provide quick and easy
2 8 relays. Fixed 45-second time delay controls the indoor access for servicing (upflow models only).
blower in heating cycles. Blower off-timing is adjustable by
presets, allowing you to customize comfort in the home. 6 Multi-port in-shot burners
Perfectly shape the flame cone for the maximum heat
2 Adaptive silicon nitride hot surface igniter possible while using less fuel. No service adjustment
Prevents overheating, which results in a highly reliable necessary.
6 ignition system and longer service life.
7 Automotive-grade gaskets and insulated
Features and components may vary by model
and are shown for illustration purposes only.
As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice.
trane.com
© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. XT80FURN-01 09/05
Trane Profit-ability
Sell-ability
Industry leader with impeccable
brand reputation
Precision engineered
TRANE LIMITED WARRANTY
Install-ability 10-year functional parts
Flush fit, easy attachment
Available for different furnace widths
Upflow, downflow and horizontal
left airflow
Service-ability
Easy-access cabinet
Suction pressure service port
Removable inner and outer panels
TXV with mechanical fittings
Performance-ability
Two-way, sloped drain pan INNOVATIVE TECHNOLOGY. INCREASED PROFIT MARGIN.
Foil-insulated cabinet Corrosion has been a long-standing problem affecting efficiency there is and exceptional durability when
Non-bleed TXV every major HVAC manufacturer. Trane’s answer to selecting this indoor coil for their matched system. The
this environmental issue is the all-new, all-aluminum innovative advancement and precision engineering
Rely-ability
Non-corrosive parts Comfort™ coil—the only one of its kind in the industry. of the aluminum Comfort coil will be a money-saving
TXV protects from refrigerant By being corrosion and rust resistant, the aluminum investment for your customer and a profit-earning
flooding Comfort coil promises your customers the highest sale for you.
© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. ALCOILS-01 09/05
Airflow Directions:
Downflow models when placed in horizontal position provide left to right airflow.
Upflow models when placed in horizontal position provide right to left airflow.
Table FUR-2-A — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUY060R9V3W 3 56,000 37,000 93.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 156 15 17 x 25 x 1
TUY080R9V3W 3 73,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 17 x 25 x 1
TUY100R9V4W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 197 15 20 x 25 x 1
TUY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 24 x 25 x 1
XV 90 Direct/ Note: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.
Non- Direct Vent
Table FUR-2-B — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Downflow/
Horizontal Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDY060R9V3W 3 56,000 36,000 92.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 160 15 (2) 14 x 20 x 1
TDY080R9V3W 3 74,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 (2) 14 x 20 x 1
TDY100R9V4W 4 94,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1
TDY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
XV 90 Direct/ Note: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.
Non- Direct Vent
Table FUR-2-C — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX060R936W 3 56,000 36,000 93.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 156 15 17 x 25 x 1
TUX080R942W 31/2 73,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 17 x 25 x 1
TUX100R948W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21x 28 197 15 20 x 25 x 1
TUX120R960W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 24 x 25 x 1
XL 90 Direct/
Non-Direct Vent
Table FUR-2-D — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Downflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX060R936W 3 55,000 36,000 92.0 2-3 Silicon Nitride 40 x 171/2 x 28 160 15 (2) 14 x 20 x 1
TDX080R942W 31/2 74,000 48,000 92.5 2-3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDX100R948W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1
TDX120R960W 5 111,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
XL 90 Direct/ 1 Isolated Combustion System.
Non-Direct Vent * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Table FUR-3-C — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX1B040A9241A 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUX1B060A9361A 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1
TUX1B080A9421A 31/2 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1
TUX1C080A9601A 5 76,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1
TUX1C100A9481A 4 94,000 92.1 21/2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1
TUX1D100A9601A 5 93,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1
XR 90 Direct Vent
TUX1D120A9601A 5 113,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 205 15 24 x 25 x 1
Table FUR-3-D — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX1B040A9241A 2 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1
TDX1B060A9361A 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDX1B080A9421A 31/2 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDX1C100A9481A 4 94,000 91.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDX1D120A9601A 5 112,000 91.0 21/2-3 Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
1 Isolated Combustion System.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Filters are not shipped with furnace.
Table FUR-4-A — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX040C924D 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUX060C936D 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1
PHASED OUT
TUX080C942D 31/2 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1
TUX080C960D 5 76,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1
TUX100C948D 4 94,000 92.1 21/2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1
TUX100C960D 5 93,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1
TUX120C960D 5 113,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 205 15 24 x 25 x 1
Table FUR-4-B — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
XR 90 Direct Vent Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX040C924D 2 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1
PHASED OUT
TDX060C936D 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDX080C942D 31/2 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDX100C948D 4 94,000 91.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDX120C960D 5 112,000 91.0 21/2-3 Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
Table FUR-4-C — XB 90 Single Stage, Single Pipe, Upflow/Horizontal Left Condensing Gas Furnace
(115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUC040C924B 2 37,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 139 15 17 x 25 x 1
TUC060C936B 3 56,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 150 15 17 x 25 x 1
TUC080C942B 31/2 74,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 158 15 17 x 25 x 1
TUC100C948B 4 94,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 21 x 28 171 20 20 x 25 x 1
TUC100C960B 5 93,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 241/2 x 28 197 15 24 x 25 x 1
TUC120C960B 5 113,000 92.1 3 Only Silicon Carbide 40 x 241/2 x 28 205 15 24 x 25 x 1
Table FUR-4-D— XB 90 Single Stage, Single Pipe, Downflow/Horizontal Right Condensing Gas Furnace
(115/1/60)
XB 90 Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDC040C924B 2 38,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1
TDC060C936B 3 56,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDC080C942B 31/2 74,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDC100C948B 4 93,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDC120C960B 5 112,000 91.0 3 Only Silicon Carbide 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
1 Isolated Combustion System.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
PHASED OUT
• Direct drive high efficiency, 4 speed motor ............................ — — ✔ — — —
• Direct drive, GE ICM variable speed blower motor ................. ✔ — — — — —
• Downflow horizontal right (downflow models only) ................. TDY TDX TDX TDX TDX TDC
• Dual PVC pipe venting (1 or 2 pipe option) ............................ ✔ ✔ ✔ ✔ ✔ —
• Single PVC pipe venting (1 pipe only) ................................... — — — — — ✔
• Dual solenoid combination gas valve and regulator ............... ✔ ✔ ✔ ✔ ✔ ✔
• Gasketed blower door ......................................................... ✔ ✔ ✔ ✔ ✔ —
• Heavy gauge reinforced wrap-around steel cabinet ............... ✔ ✔ ✔ ✔ ✔ ✔
• Hinged blower door ............................................................ ✔ ✔ ✔ ✔ ✔ —
• Humidifier/EAC hook-up capability (factory wired) ................. ✔ ✔ ✔ ✔ ✔ ✔
• Inner blower door panel, downflow models only .................... TDY TDX TDX TDX TDX TDC
• Insulated blower compartment 4 sides ................................. ✔ ✔ ✔ ✔ ✔ —
• Cleanable Filters ................................................................ ✔ ✔ — — ✔ —
• Internal filter rack ................................................................ ✔ ✔ — — ✔ —
• Left/right condensate drain capability in vertical application ..... ✔ ✔ — ✔ ✔ ✔
• Lite Port/Stored diagnotics .................................................. ✔ ✔ — — — —
• Mobile home approved w/BAYMFGH100A ........................... ✔ ✔ ✔ ✔ ✔ —
• Multi-port in shot burners ..................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Painted cabinet single color ................................................. — — — — — ✔
• Painted cabinet two tone color ............................................. ✔ ✔ ✔ ✔ ✔ —
• Service diagnostic capabilities ............................................. ✔ ✔ ✔ ✔ ✔ ✔
• Side out blower assembly ................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Side return duct starter tabs ................................................ ✔ ✔ ✔ ✔ ✔ ✔
• Silicon Carbide hot surface igniter with adaptive heat up ........ — — — — — ✔
• Silicon Nitride hot surface igniter with adaptive heat up ........... ✔ ✔ ✔ ✔ ✔ —
• Single wire twinning ............................................................ — ✔ ✔ ✔ ✔ —
• Solid burner door (quiet operation) ....................................... ✔ ✔ ✔ ✔ ✔ —
• 20 gauge aluminized steel heat exchanger ........................... ✔ ✔ ✔ ✔ ✔ ✔
• 24 volt secondary fuse ........................................................ ✔ ✔ ✔ ✔ ✔ ✔
• Two heating blower speeds ................................................. ✔ ✔ — — — —
• Two-stage gas valve ........................................................... ✔ ✔ — — — —
• Type 29-4C™ stainless steel secondary heat exchanger ....... ✔ ✔ ✔ ✔ ✔ ✔
• Upflow horizontal left (upflow models only) ............................ TUY TUX TUX TUX TUX TUC
• Variable Speed venter motor ............................................... ✔ ✔ — — — —
• Limited lifetime heat exchanger warranty to original owner and ✔ ✔ ✔ ✔ ✔ ✔
20-years to succeeding homeowner from date of installation
• 5-year limited warranty on parts* .......................................... ✔ ✔ ✔ ✔ ✔ ✔
NOTE: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.
PHASED OUT
BAY69X148 ...........
Wall mount flange – 2" .................................. — —
BAYBASE205 ........ Downflow subbase ....................................... ✔ ✔ ✔ ✔ ✔ ✔
BAYFLTR200 .........External side filter rack .................................. ✔ ✔ ✔ ✔ ✔ ✔
BAYFLTR203 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔
for 17.5" cabinet
BAYFLTR204 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔
for 21" cabinet
BAYFLTR205 ........ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔
for 24.5" cabinet
BAYFLTR206 ........ Filter kit ....................................................... — — ✔ ✔ ✔ ✔
BAYFLTR3171 .... Cleanable filter for 17.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔
cabinet upflow only
BAYFLTR3211 .... Cleanable filter for 21" ............................... ✔ ✔ ✔ ✔ ✔ ✔
cabinet upflow only
BAYFLTR3241 .... Cleanable filter for 24.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔
cabinet upflow only
BAYLPKT210B ..... Propane conversion kit .................................. ✔ ✔ ✔ ✔ ✔ ✔
BAYLPSS210B .... LP Kit with Stainless ................................... ✔ ✔ ✔ ✔ ✔ ✔
Steel Burners
BAYMFGH100A .... Manufactured/mobile .................................. ✔ ✔ ✔ ✔ ✔ —
home kit
BAYRACK960A .... Filter rack kit for upflow ............................... TUY TUX ✔ TUX TUX TUC
models only (internal)23
BAYVENT100A ..... Concentric vent kit for 2, ............................. ✔ ✔ ✔ ✔ ✔ —
1
2 /2 and 3" vent system
BAYVENT200B ..... Sidewall vent Terminator ............................. ✔ ✔ ✔ ✔ ✔ —
Kit for Direct vent furnaces
1 Contains one (1) high velocity filter. 3 Includes 17" Cleanable Filter.
2 Internal filter rack for side or bottom return air. NOTE: Variable Speed XV90 Furnaces should not be twinned and are not approved for twinning applications.
Table FUR-8-A — XV 80 Variable Speed, Two-Stage, Upflow/Horizontal Left or Right Induced Draft Gas
Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUD060R9V3K 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 136 15 17 x 25 x 1
TUD080R9V3K 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080R9V4K 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 17 x 25 x 1
TUD100R9V3K 3 80,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD100R9V5K 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 20 x 25 x 1
XV 80 TUD120R9V5K 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 15 24 x 25 x 1
TUD140R9V5K 5 111,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1
NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.
Table FUR-8-B — XV 80 Variable Speed, Two-Stage, Downflow/Horizontal Left or Right Induced Draft Gas
Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDD060R9V3F 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 140 15 (2) 14 x 20 x 1
TDD080R9V3F 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD100R9V5F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1
TDD120R9V5F 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 (2) 16 x 20 x 1
NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.
XV 80
Table FUR-8-C — XL 80 Two-Stage, Upflow/Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUD040R924K 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1**
TUD060R936K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1**
TUD060R937K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1
TUD080R936K 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080R948K 4 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD100R936K 3 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1
XL 80 TUD100R948K 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD100R960K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD100R961K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1
TUD120R954K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1
TUD120R960K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
TUD140R960K 5 112,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 192 20 24 x 25 x 1
Table FUR-9-A — XT 80 Single Stage, Upflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TUD1A040A9H21A 2 32,000 80 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1
TUD1B060A9H31A 3 47,000 80 4 Silicon Nitride 40 x 171/2 x 28 127 15 17 x 25 x 1
TUD1B080A9H31A 3 63,000 80 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD1C080A9H41A 4 64,000 80 4 Silicon Nitride 40 x 21 x 28 142 20 20 x 25 x 1
TUD1B100A9H31A 3 79,000 80 4 Silicon Nitride 40 x 171/2 x 28 151 20 17 x 25 x 1
TUD1C100A9H51A 5 79,000 80 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1
TUD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
XT 80 TUD1D140A9H51A 5 111,000 80 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1
Upflow
Table FUR-9-B — XT 80 Single Stage, Downflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDD1B060A9H31A 3 48,000 80 4 Silicon Nitride 40 x 171/2 x 28 139 15 (2) 14 x 20 x 1
TDD1B080A9H31A 3 64,000 80 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD1C100A9H51A 5 81,000 80 4 Silicon Nitride 40 x 21 x 28 167 20 (2) 16 x 20 x 1
TDD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2) 16 x 20 x 1
Table FUR-9-C — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
XT 80 Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
Downflow TUD1A040A9241A 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1
TUD1A040A9301A 21/2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1
TUD1A060A9241A 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1
TUD1A060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1
TUD1B060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1
TUD1B080A9241A 2 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUD1B080A9361A 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD1B080A9481A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD1C080A9601A 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1
TUD1C100A9361A 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1
TUD1C100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1
TUD1C100A9481A 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD1C100A9601A 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1
TUD1D100A9721A 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1
XR 80 TUD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1
TUD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
TUD1D140A9601A 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1
Table FUR-9-D — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDD1A040A9241A 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 (2) 14 x 20 x 1
TDD1A060A9241A 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD1A060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD1B060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 141 15 (2) 14 x 20 x 1
TDD1B080A9361A 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD1B080A9451A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD1B100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 156 15 (2) 14 x 20 x 1
TDD1C100A9481A 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1
XR 80 TDD1C100A9541A 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 15 (2) 16 x 20 x 1
TDD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 15 (2) 16 x 20 x 1
TDD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 15 (2) 16 x 20 x 1
TDD1D140A9601A 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Filters are not shipped with furnace.
PHASED OUT
TUD080C936K 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080C948K 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080C960K 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1
TUD100C936K 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1
TUD100C945K 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1
XR 80 TUD100C948K 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD100C960K 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1
TUD100C972K 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1
TUD120C954K 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1
TUD120C960K 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
TUD140C960K 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1
Table FUR-10-B — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDD040C924F 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 (2) 14 x 20 x 1
TDD060C924F 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD060C936F 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD060C937F 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 141 15 (2) 16 x 20 x 1
TDD080C936F 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
XR 80
TDD080C945F
TDD100C945F
TDD100C948F
TDD100C954F
TDD120C954F
TDD120C960F
PHASED OUT4
4
4
5
5
5
64,000
80,000
80,000
81,000
96,000
96,000
80.0
80.0
80.0
80.0
80.0
80.0
4
4
4
4
4
4
Silicon Nitride
Silicon Nitride
Silicon Nitride
Silicon Nitride
Silicon Nitride
Silicon Nitride
40 x 171/2 x 28
40 x 171/2 x 28
40 x 21 x 28
40 x 21 x 28
40 x 21 x 28
40 x 241/2 x 28
146
156
166
167
177
189
15
15
15
15
15
15
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
TDD140C960F 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1
Table FUR-10-C — XB 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TUE040A924L 2 31,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 119 15 16 x 25 x 1
TUE060A936L 3 47,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 127 15 16 x 25 x 1
TUE060A937L 3 47,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 137 15 17 x 25 x 1
TUE080A936L 3 63,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 142 15 17 x 25 x 1
TUE080A948L 4 64,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 142 15 17 x 25 x 1
TUE100A936L 3 79,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 151 15 17 x 25 x 1
TUE100A948L 4 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1
TUE100A960L 5 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1
TUE120A960L 5 96,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 186 20 24 x 25 x 1
XB 80 TUE140A960L 5 111,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 193 20 24 x 25 x 1
Table FUR-10-D — XB 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDE060A936M 3 48,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDE060A937M 3 48,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 134 15 (2) 14 x 20 x 1
TDE080A945M 4 64,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDE100A945M 4 80,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 156 15 (2) 14 x 20 x 1
TDE100A960M 5 81,000 80.0 4 Silicon Carbide 40 x 21 x 28 167 20 (2) 16 x 20 x 1
TDE120A960M 5 96,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 189 20 (2) 16 x 20 x 1
*Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
For complete equipment / combination
Effective 1/1/06 FUR-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XV, XL, XT, XR, XB 80
Convertible Gas Furnaces
Airflow Directions:
Downflow models when placed in horizontal position provide left XV 80 XL 80 XT 80 XR 80 XR 80 XB 80
to right airflow. Upflow models when placed in horizontal position TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE/TDE
provide right to left airflow. TDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-K 1 Stage
Variable Speed 2 Stage 1 or 2 Pipe 1 Stage
Table FUR-11-A — Features High Efficiency
• Comfort-R™ enhanced mode (cooling) ............................. ✔ — — — — —
• Adjustable heating fan off timing .......................................... ✔ ✔ ✔ ✔ ✔ ✔
• Adjustable internal filter rack1 ............................................ ✔ ✔ — — ✔ —
• Alternate bottom/left/right return air1 ................................... ✔ ✔ ✔ ✔ ✔ ✔
• Attractive color accents ...................................................... ✔ ✔ ✔ ✔ ✔ —
• Blower door safety switch ................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Bottom Panel1 ................................................................. ✔ ✔ ✔ ✔ ✔ —
• Cleanable/reusable high velocity filters ................................ ✔ ✔ — — ✔ —
• Common vent capability ..................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Complete front service access ........................................... ✔ ✔ ✔ ✔ ✔ ✔
• Direct drive, 4-speed motor ................................................ — ✔ ✔ ✔ ✔ ✔
• Direct drive,GE ICM variable speed blower motor ................ ✔ — — — — —
PHASED OUT
• Filter ................................................................................. ✔ ✔ — — ✔ —
• Gasketed blower door ........................................................ ✔ ✔ ✔ ✔ ✔ —
• Heavy gauge reinforced wrap-around steel cabinet .............. ✔ ✔ ✔ ✔ ✔ ✔
• Hinged blower door1 ........................................................ ✔ ✔ ✔ ✔ ✔ —
• Horizontal left/right without conversion required .................... ✔ ✔ ✔ ✔ ✔ ✔
• Humidifier/EAC hook-up capability (factory-wired) ................ ✔ ✔ ✔ ✔ ✔ —
• Inner blower door panel on downflow models only ................ ✔ ✔ ✔ ✔ ✔ ✔
• Insulated blower compartment 4 sides1 ............................. ✔ ✔ ✔ ✔ ✔ —
• Integrated solid state control w/self diagnostics .................... ✔ ✔ ✔ ✔ ✔ ✔
• Internal filter rack ............................................................... ✔ ✔ — — ✔ —
• Left/right gas connection .................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Manual reset flame roll out switches .................................... ✔ ✔ ✔ ✔ ✔ ✔
• Manually resettable burner switches ................................... ✔ ✔ ✔ ✔ ✔ ✔
• Masonry Chimney Venting w/BAYVENT800B ...................... ✔ ✔ ✔ ✔ ✔ —
• Multi-port in shot burners .................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Painted cabinet single color ................................................ — — — — — ✔
• Perfect fit door latches1 ..................................................... ✔ ✔ ✔ ✔ ✔ —
• Right or left hand side knock out for venting ......................... ✔ ✔ ✔ ✔ ✔ ✔
(downflow models only)
• Selectable cooling fan off delay eliminates need ................... ✔ ✔ ✔ ✔ ✔ ✔
for time delay relay BAY24X045
• Service diagnostic sight glass ............................................. ✔ ✔ ✔ ✔ ✔ —
• Side return starter tabs ...................................................... TUD TUD TUD TUD TUD TUE
• Silicon Carbide hot surface igniter with adaptive heat up ....... — — — — — ✔
• Silicon Nitride hot surface igniter with adaptive heat up .......... ✔ ✔ ✔ ✔ ✔ —
• Single door filter access ..................................................... ✔ ✔ ✔ ✔ ✔ —
• Single wire twinning ........................................................... — ✔ ✔ ✔ ✔ —
• Slide out blower assembly .................................................. ✔ ✔ ✔ ✔ ✔ ✔
• Standard filter sizes1 ........................................................ ✔ ✔ ✔ ✔ ✔ —
• 3-way vent option on downflow models (top,right or left) ........ ✔ ✔ ✔ ✔ ✔ ✔
(downflow only) .................................................................
• 20 gauge aluminized steel heat exchanger .......................... ✔ ✔ ✔ ✔ ✔ ✔
• 24 volt secondary fuse ....................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Two heating blower speeds ............................................... ✔ ✔ — — — —
• Two speed venter motor .................................................... ✔ ✔ — — — —
• Two tone color ................................................................... ✔ ✔ ✔ ✔ ✔ —
• Two-stage gas valve .......................................................... ✔ ✔ — — — —
• Non-prorated 20-year heat exchanger limited warranty ......... ✔ ✔ ✔ ✔ ✔ ✔
(Residential only)*
• 5-year limited warranty on parts* ......................................... ✔ ✔ ✔ ✔ ✔ ✔
1 Upflow only.
NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.
PHASED OUT
downflow models only
BAYFLTR200 ............ Side Filter Rack (External) .......................... ✔ ✔ — TUD1 — —
BAYFLTR203 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔
for 17.5" cabinet
BAYFLTR204 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔
for 21" cabinet
BAYFLTR205 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔
for 24.5" cabinet
BAYFLTR206 ............ Filter Access Door Kit ................................ ✔ ✔ TDD1 TDD1 ✔ ✔
BAYFLTR3171 ......... Cleanable filter for 14.5" ........................... — — ✔ ✔ — ✔
and 17.5" cabinet upflow only
BAYFLTR3211 ......... Cleanable filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔
21" cabinet upflow only
BAYFLTR3241 ......... Cleanable filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔
24.5" cabinet upflow only
BAYLPKT210B ......... Propane conversion kit ............................... ✔ ✔ ✔ ✔ ✔ ✔
BAYLPSS210B ......... LP Kit with Stainless .................................. ✔ ✔ ✔ ✔ ✔ ✔
Steel Burners
BAYRACK960A235 . Filter Rack Kit for upflow ............................. TUD TUD ✔ ✔ TUD TUE
models only (internal)
BAYVENT800B4 ...... Masonry chimney vent kit ........................... ✔ ✔ ✔ ✔ — —
1 Contains one (1) high velocity filter.
2 Available for models with 1800 CFM or greater witch require an additional side return.
3 Upflow only.
4 TUD-C-J/TUD-R-J and later
5 Includes 17" Cleanable Filter.
NOTE: Variable Speed XV80 Furnaces should not be twinned and are not approved for twinning applications.
12
Table FUR-12-C — Dual Fuel Heat Pump Control Kit12
Model Number Case Height Used With
TAYPLUS103A ........... Heat Pump Control Kit ........... Gas, LP., Oil and Electric Furnaces
TAYSTAT250B ........... Outdoor Thermostat ............... TAYPLUS103A for Restricted Mode
THT1248 ..................... Bonnet Switch ........................ Oil Furnaces Only (Order Separately)
Bonnet TAYPLUS103A 1 Factory wired for non-restricted mode, can be wired for restricted mode.
Switch 2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required).
TLF -
TDF - Lowboy Front THV -
Downflow/Horizontal Flue (TLR not shown) Highboy Vertical
• Up to 82.7% Annual Fuel Utilization Efficiency • Slide out blower assembly for quick • Recessed door handles for easy removal of
(AFUE) cleaning and service accessibility Highboy & lowboy Furnace doors
• 13 gauge hot rolled steel wrap around heat • Filter rack with cleanable filter (Highboy & • Lowboy models available with front or rear
exchanger for durability Lowboy Models) except Downflow/ flue option
• Beckett Flame Retention Burner operates Horizontal • Highboy models with top or right side
cleanly and quietly • 5 year limited parts warranty venting
• Burner features include primary control with • Limited lifetime heat exchanger warranty • Downflow/Horizontal model field
interrupted ignition for reliability, pre-purge and • Preformed ceramic fiber convertible from Downflow to right or left
clean cutoff solenoid valve for smooth ignition combustion chamber for higher efficiencies horizontal
• Burner and controls factory wired and more complete combustion • 6” Left and Right side fresh air knockouts –
• Dual clean out ports for quick access and easy • 40 VA control transformer for add on Highboy and Lowboy Models
cleaning cooling • Barometric draft regulator included
• Insulated blower compartment • Heavy gauge, powder painted (two tone),
• Variable speed blower motor steel cabinet
TLF -
TDF - Lowboy Front THV -
Downflow/Horizontal Flue (TLR not shown) Highboy Vertical
• Up to 82.4% Annual Fuel Utilization • Insulated blower compartment • Recessed door handles for easy removal of
Efficiency (AFUE) • Slide out blower assembly for quick cleaning Highboy & lowboy Furnace doors
• 13 gauge hot rolled steel wrap around heat and service accessibility • Lowboy models available with front or rear
exchanger for durability • Filter rack with washable filter (Highboy & flue option
• Beckett Flame Retention Burner operates Lowboy Models) except Downflow/Horizontal • Highboy models with top or right side
cleanly and quietly • 5 year parts limited warranty and lifetime heat venting
• Burner features include primary control with exchanger warranty • Downflow/Horizontal model field
interrupted ignition for reliability, pre-purge • Preformed ceramic fiber convertible from Downflow to right or left
and clean cutoff solenoid valve for smooth combustion chamber for higher efficiencies horizontal
ignition and more complete combustion • 6” Left and Right side fresh air knockouts –
• Burner and controls factory wired • 40 VA control transformer for add on cooling Highboy and Lowboy Models
• Dual clean out ports for quick access and • Heavy gauge, powder painted (two tone), • Barometric draft regulator included
easy cleaning steel cabinet
• Direct drive, permanently lubricated, 4
speed blower motor
Specifications:
Furnace Nom. Blower Flue Propane Outlet Return Air
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Air Bottom Side
Number2 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H D
UPFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT/NON DIRECT VENT TWO-STAGE
TUY060R9V3W 56,000 93.0 1275 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUY080R9V3W 73,000 92.5 1400 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUY100R9V4W 93,000 93.0 1770 Var. Var. 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUY120R9V5W 112,000 92.5 1920 Var. Var. 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XL 90 DIRECT/NON-DIRECT VENT, TWO STAGE, 1 OR 2 PIPE, UPFLOW/HORIZONTAL CONDENSING GAS FURNACE
TUX060R936W 56,000 93.0 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX080R942W 73,000 92.5 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX100R948W 93,000 93.0 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUX120R960W 112,000 92.5 2261 4 3/4 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)
TUX1B040A9H21A 38,000 92.1 1052 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B060A9H31A 56,000 92.1 1248 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B080A9H31A 74,000 92.1 1320 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1C100A9H41A 94,000 92.1 1737 4 3/4 21/2, 3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUX1D120A9H51A 113,000 92.1 2023 4 1.0 21/2, 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)
TUX1B040A9241A 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B060A9361A 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B080A9421A 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B080A9601A 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1C100A9481A 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUX1C100A9601A 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUX1D120A9601A 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGE
TUC040C924B 37,000 92.1 812 4 1/5 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUC060C936B 56,000 92.1 1196 4 1/3 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUC080C942B 74,000 92.1 1470 4 1/3 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUC100C948B 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUC100C960B 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUC120C960B 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT/NON DIRECT VENT SINGLE STAGE
TUX040C924D 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX060C936D 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX080C942D
TUX080C960D
TUX100C948D
TUX100C960D
TUX120C960D
74,000
76,000
94,000
93,000
113,000
92.1
92.1
92.1
92.1
92.1
PHASED OUT
1470
2121
1746
2165
2261
4
4
4
4
4
1/3
1/2
1/2
1/2
1/2
2–3
2–3
1
2 /2–3
1
2 /2–3
3 Only
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
16.25
16.25
19.75
23.25
23.25
19.6
19.6
19.6
19.6
19.6
16
16
19
23
23
23.5
23.5
23.5
23.5
23.5
14.88
14.88
14.88
14.88
14.88
23.75
23.75
23.75
23.75
23.75
1 Isolated Combustion System.
2 CFM @ .5 inches ESP with filter in place.
Specifications:
Furnace Nom. Blower Flue Propane Outlet Return
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Downflow Air Air
Number Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H D
DOWNFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT VENT TWO-STAGE
TDY060R9V3W 56,000 92.0 1350 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDY080R9V3W 74,000 92.5 1210 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDY100R9V4W 94,000 93.0 1800 Var. Var. 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDY120R9V5W 112,000 92.5 1900 Var. Var. 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL— XL 90 NON-DIRECT VENT, TWO STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDX060R936W 55,000 92.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX080R942W 74,000 92.5 1323 4 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX100R948W 93,000 93.0 1614 4 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDX120R960W 111,000 92.5 1939 4 3/4 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDX1B040A9H31A 38,000 91.0 1043 4 1/2 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B060A9H31A 56,000 91.0 1223 4 1/2 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B080A9H31A 74,000 91.0 1423 4 3/4 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
1
TDX1C100A9H41A 94,000 91.0 1700 4 3/4 2 /2, 3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
1
TDX1D120A9H51A 112,000 91.0 2006 4 1.0 2 /2, 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDX1B040A9241A 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B060A9361A 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B080A9421A 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1C100A9481A 94,000 91.0 1614 3 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDX1D120A9601A 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGE
1
TDC040C924B 38,000 91.0 807 4 1/5 2 /2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDC060C936B 56,000 91.0 1082 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDC080C942B 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDC100C948B 93,000 91.0 1614 3 1/2 2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDC120C960B 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23.0 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT VENT SINGLE STAGE
TDX040C924D 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX060C936D
TDX080C942D
TDX100C948D
TDX120C960D
56,000
74,000
94,000
112,000
1 Isolated Combustion System.
91.0
91.0
91.0
91.0
PHASED OUT
1209
1323
1614
1939
4
3
3
3
1/3
1/2
1/2
1/2
2–3
2–3
21/2–3
3 Only
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYBASE205
BAYBASE205
BAYBASE205
BAYBASE205
16
16
19.5
23
19.6
19.6
19.6
19.6
16.25
16.25
19.75
23.25
19.6
19.6
19.6
19.6
PHASED OUT
TUD080C936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080C948K 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080C960K 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75
TUD100C936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD100C945K 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55
TUD100C948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD100C960K 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75
TUD100C972K 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD120C954K 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD120C960K 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD140C960K 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
1 Isolated Combustion System. 2 CFM @ .5 inches ESP with filter in place.
For complete equipment / combination
selections and installation instructions, please FUR-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Downflow/Horizontal
80% Gas Furnace Quick Reference
Specifications:
Furnace Nom. Blower Flue Propane Outlet Return
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Downflow Air Air
Number Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H D
DOWNFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO STAGE
TDD060R9V3F 48,000 80.0 1360 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD080R9V3F 63,000 80.0 1315 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100R9V5F 81,000 80.0 2015 Var. Var. 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120R9V5F 95,000 80.0 2215 Var. Var. 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XL 80 TWO-STAGE INDUCED DRAFT
TDD040R924F 32,000 80.0 960 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060R936F 47,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060R937F 47,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD080R936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100R945F 79,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100R948F 79,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD100R960F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120R960F 94,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
TDD140R960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDD1B060A9H31A 48,000 80.0 1309 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B080A9H31A 64,000 80.0 1314 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1C100A9H51A 81,000 80.0 2007 4 1.0 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1D120A9H51A 96,000 80.0 2010 4 1.0 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDD1A040A9241A 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD1A060A9241A 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD1A060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD1B060A9361A 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B080A9361A 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B080A9451A 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B100A9451A 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1C100A9481A 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1C100A9541A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1C120A9541A 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1D120A9601A 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
TDD1D140A9601A 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XB 80 INDUCED DRAFT SINGLE STAGE
TDE060A936M 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDE060A937M 48,000 80.0 1281 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDE080A945M 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDE100A945M 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDE100A960M 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDE120A960M 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGE
TDD040C924F 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060C924F 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060C936F 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060C937F 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
PHASED OUT
TDD080C936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD080C945F 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100C945F 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100C948F 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD100C954F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120C954F 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120C960F 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
TDD140C960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
1 Isolated Combustion System.
2 CFM @ .5 inches ESP with filter in place.
AIRFLOW
Table FUR-19-E — Reversible, Cased Heat Pump/Cooling Coils — (Upflow/Downflow Horizontal Left
or Right) R-22 Refrigerant
Reversible Features: Nom. Cap. Maximum Outlet Overall Shipping Line Size
• Bi-Directional Airflow Model Cooling Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Same side service access for Number (Btuh) (CFM**) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
Horizontal Right or Left 2TXCA024AC3HMA 24,000 1000 A TXVNB1 125/8 x 193/8 30 x 14.5 x 21.5 1000 3
/4 5
/16
applications 2TXCB036AC3HMA 36,000 1200 A TXVNB1 155/8 x 193/8 30 x 17.5 x 21.5 1200 7
/8 3
/8
• Eliminates need for field 1 Start Kits may be required on outdoor unit.
installed Horizontal Drip 2 7/8 x 3/4 reducing coupling shipped with R-410A model coil.
Tray!!! 3 11/8 x 7/8 reducing coupling shipped with R-410A model coil.
• Fully Convertible - Upflow, *Overall height. Actual height of case is 30".
Downflow, Left or Right **Water Blowoff may occur if Maximum Cooling airflow is exceeded.
• Heat Pump and Cooling
Compatible
• Suction service port
• 100% foil lined insulation
• Split inner and outer doors for
easy coil cleaning
• Double sloped non-corrosive
drain pan - UL rated 400°F
• 5 year limited parts warranty
on all coils
• Non-Bleed TXV with
mechanical fittings
For complete equipment / combination
selections and installation instructions, please FUR-19 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System – Cased
Heat Pump and Cooling Coils
Table FUR-20-A — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-22 Refrigerant
Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
2TXCA018AC3HCA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 34 5
/8 1
/4
2TXCA024AC3HCA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 37 3
/4 5
/16
Comfort TM coil
2TXCB025AC3HCA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3
/4 5
/16
2TXCB031AC3HCA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 46 3
/4 5
/16
2TXCB036AC3HCA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 54 7
/8 3
/8
2TXCC037AC3HCA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7
/8 3
/8
2TXCB042AC3HCA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 59 7
/8 3
/8
TXC Comfort™ 2TXCC043AC3HCA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3
/8
Coil Features: 2TXCB048AC3HCA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 71 11/8 3
/8
2TXCC049AC3HCA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3
/8
• HP TXV Mechanical 2TXCD050AC3HCA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3
/8
Fittings (2/4 TXC) 2TXCC060AC3HCA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 74 11/8 3
/8
• Split inner and outer doors 2TXCD061AC3HCA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 77 11/8 3
/8
for easy coil cleaning
• Double sloped non Table FUR-20-B — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-410A Refrigerant
corrosive drain pans- Nom. Cap. Outlet Overall Shipping Line Size
UL Rated 400°F Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Suction pressure service Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
5 3 5 1
port 4TXCA018AC3HCA 18,000 A TXVNB1 12 /8 x 19 /8 17.6 x 14.5 x 21.5 34 /8 /4
5 3 3 5
• 100% foil lined insulation 4TXCA024AC3HCA 24,000 A TXVNB 1 12 /8 x 19 /8 22.6 x 14.5 x 21.5 37 /4 /16
• Easy case attachment to 4TXCB025AC3HCA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3
/4 5
/16
furnace 4TXCB031AC3HCA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 46 3
/4 5
/16
• 3 way application 4TXCB036AC3HCA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 54 7
/8 3
/8
• Painted cabinet matches 4TXCC037AC3HCA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7
/8 3
/8
furnace 4TXCB042AC3HCA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 59 7
/8 3
/8
• 5 year limited parts 4TXCC043AC3HCA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3
/8
warranty 4TXCB048AC3HCA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 71 11/8 3
/8
• Copper tube Aluminum fin 4TXCC049AC3HCA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3
/8
4TXCD050AC3HCA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3
/8
4TXCC060AC3HCA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 74 11/8 3
/8
4TXCD061AC3HCA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 77 11/8 3
/8
Table FUR-21-C — Cooling Only Uncased Coils (Upflow/ Downflow) R-410A Refrigerant
Nom. Cap. Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Weight OD OD
Number (Btuh) Type Control H x W x D (Ibs.) Gas Liq.
4CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5
/8 1
/4
4CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3
/4 5
/16
4CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3
/4 5
/16
4CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3
/4 5
/16
4CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7
/8 3
/8
4CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7
/8 3
/8
2/4CXA Coil Features:
• Uncased upflow /downflow 4CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7 3
/8 /8
4CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 11/8 3
/8
cooling only coils
4CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 11/8 3
/8
• Brazed fittings (left side)
• Drain fitting (left side) 4CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 11/8 3
/8
4CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 11/8 3
/8
• Non-Bleed TXV with
4CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 11/8 3
/8
mechanical fittings.
• Copper tube with Aluminum 4CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 11/8 3
/8
1 Start Kits may be required on outdoor unit.
fins
• Suction pressure service
port
• Split inner for easy coil
cleaning
• 5 Year limited parts
warranty
Table FUR-22-B — Brazed, Cased Dual Circuit Cooling Only Coils-(Upflow, Downflow or Horizontal Left Only)
Nom. Cap. Outlet Overall Shipping Line Size
TXC Comfort™ Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Coil Features: Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
• Split inner and outer doors TXC039E300C2 36,000 A TXVNB1 155/8 x 195/16 301/16 x 171/2 x 211/2 69 3
/4 5
/16
for easy coil cleaning TXC059E300C2 59,000 A TXVNB1 191/8 x 195/16 301/16 x 21 x 211/2 73 7
/8 3
/8
• Double sloped non
TXC062E300C2 64,000 A TXVNB1 225/8 x 195/16 301/16 x 241/2 x 211/2 79 7
/8 3
/8
corrosive drain pans-
UL Rated 400°F 1 Start Kits may be required on outdoor unit.
• Suction pressure service 2 Only used with Variable Speed Gas Furnace to achieve 2-stage heat/cool.
*Overall height. Actual height of case is 30".
port
• 100% foil lined insulation
Table FUR-22-C — Comfort™ Coils Brazed Coils* (Upflow/Downflow/Horizontal Left Only)
• Easy case attachment to
R-410A Refrigerant
furnace
Nom. Cap. Outlet Uncrated Shipping Line Size
• 3 way application Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Painted cabinet matches Number (Btuh) Type Control Cased W/H x D H x W x D (Ibs.) Gas Liq.
furnace
• 5 Year limited parts RXC025S3HPD 24,000 A TXVNB1 Full 155/8 x 195/16 175/8 x 171/2 x 211/2 42 5
/8 5
/16
warranty on all coils RXC031S3HPC 30,000 A TXVNB1 Full 155/8 x 195/16 225/8 x 171/2 x 211/2 54 3
/4 5
/16
• Copper tube and RXC036S3HPD 36,000 A TXVNB1 Full 155/8 x 195/16 267/8 x 171/2 x 211/2 67 3
/4 3
/8
Aluminum fin RXC037S3HPD 36,000 A TXVNB1 Full 191/8 x 195/16 267/8 x 21 x 211/2 70 3
/4 3
/8
RXC ComfortTM Coil RXC054S3HPC 54,000 A TXVNB1 Full 191/8 x 195/16 301/16 x 21 x 211/2 73 7
/8 3
/8
Features RXC061S3HPC 60,000 A TXVNB1 Full 2211/16 x 195/16 301/16 x 241/2 x 211/2 77 7
/8 3
/8
• Refrigerant R-410A only RXC065S3HPC 60,000 A TXVNB1 Partial 225/8 x 195/16 2337/8 x 241/2 x 211/2 94 7
/8 3
/8
• Split inner and outer
doors for easy coil
Table FUR-22-D — Brazed Uncased Coils* (Upflow/Downflow) R-410A Refrigerant
cleaning
Nom. Cap. Uncrated Line Size
• Double sloped non- Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
corrosive drain pans Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
(UL Rated 400oF)
• Suction pressure RXA060S3HPC 60,000 A TXVNB1 None 28 x 199/16 x 199/16 46 3
/4 3
/8
3 3
service port RXA061S3HPC 60,000 A TXVNB1 None 277/16 x 234/16 x 199/16 47 /4 /8
• 100% foil lined insulation 1 Start Kits may be required on outdoor unit.
• Easy case attachment 2 Overall height. Actual height of case is 30". Downflow application of RXC065 requires field fabrication of case extension shown in
to furnace the Installer's Guide.
• Painted cabinet matches Note: RXC, RXA and RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing
furnace recommended with R-410A systems
• 3 way application
• 5-year limited parts Table FUR-22-E — Brazed, Cased Dual Circuit Cooling Only Coil23
warranty Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
RXA ComfortTM Coil
TXE120B500D 120,000 Flat TXV-B 183/4 x 573/4 26 x 64 x 25 235 11/8 3
/8
Features
1 Start Kits may be required on outdoor unit.
• Double sloped non-
2 Coils are 3/8" cu/al plate fin.
corrosive drain pan 3 Two circuit cooling coil.
(UL Rated 400oF)
• Suction pressure
service port
• Easy access service
panels
• 5-year limited parts
warranty
Table FUR-23-A — Brazed, Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left Only*)
Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
TXC018C4HPC 18,000 A .049 125/8 x 193/8 175/8 x 141/2 x 211/2 32 5
/8 1
/4
TXC024C4HPC 24,000 A .049 125/8 x 193/8 175/8 x 141/2 x 211/2 34 3
/4 5
/16
TXC025C4HPC 24,000 A .057 155/8 x 193/8 175/8 x 171/2 x 211/2 39 3
/4 5
/16
TXC030C4HPC 30,000 A .067 125/8 x 193/8 225/8 x 141/2 x 211/2 37 3
/4 5
/16
TXC031C4HPC 31,000 A .067 155/8 x 193/8 175/8 x 171/2 x 211/2 43 3
/4 5
/16
PHASED OUT
TXC035C4HPC 35,000 A .071 125/8 x 193/8 225/8 x 141/2 x 211/2 37 7
/8 3
/8
TXC036C4HPC 36,000 A .071 155/8 x 193/8 225/8 x 171/2 x 211/2 51 7
/8 3
/8
TXC037C4HPC 37,000 A .071 191/8 x 193/8 225/8 x 21 x 211/2 54 7
/8 3
/8
TXC042C4HPC 42,000 A .080 155/8 x 193/8 225/8 x 171/2 x 211/2 56 7
/8 3
/8
1 – 5 Ton TXC043C4HPC 43,000 A .080 191/8 x 193/8 225/8 x 21 x 211/2 57 11/8 3
/8
Cased Coils TXC048C4HPD 48,000 A .083 155/8 x 193/8 267/8 x 171/2 x 211/2 68 11/8 3
/8
• Split inner and outer TXC049C4HPD 48,000 A .083 191/8 x 193/8 267/8 x 21 x 211/2 69 11/8 3
/8
doors for easy coil TXC050C4HPD 48,000 A .083 225/8 x 195/16 267/8 x 241/2 x 211/2 69 11/8 3
/8
cleaning TXC060C5HPC 60,000 A TXV-B 191/8 x 193/8 301/16 x 21 x 211/2 69 11/8 3
/8
• Double sloped non TXC061C5HPC 61,000 A TXV-B 225/8 x 195/16 301/16 x 241/2 x 211/2 71 11/8 3
/8
corrosive drain pans-
UL Rated 400° F Table FUR-23-B —Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow or
• Suction pressure service Horizontal Left Only*)
port Nom. Cap. Outlet Overall Shipping Line Size
• 100% foil lined insulation Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• External FCCV location Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
PHASED OUT
• Easy case attachment to TXC031E5HPC 30,000 A TXV-B 155/8 x 193/8 225/8 x 171/2 x 211/2 54 3
/4 5
/16
furnace TXC036E5HPD 36,000 A TXV-B 155/8 x 193/8 267/8 x 171/2 x 211/2 67 7
/8 3
/8
• 3 way application TXC037E5HPD 37,000 A TXV-B 191/8 x 193/8 267/8 x 21 x 211/2 70 7
/8 3
/8
• Painted cabinet matches TXC054E5HPC 54,000 A TXV-B 191/8 x 193/8 301/16 x 21 x 211/2 73 11/8 3
/8
furnace
• 5 year limited parts Table FUR-23-C — Brazed,Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left or Right)
warranty on all coils Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• FCCV equipped coils Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
compatible with R-22 or
R-410A refrigerant TXC024D4HPC 24,000 A .057 125/8 x 193/8 301/16 x 141/2 x 211/2 42 3
/4 5
/16
TXC025D4HPC 24,000 A .057 155/8 x 193/8 301/16 x 171/2 x 211/2 48 3
/4 5
/16
PHASED OUT
• Upflow, downflow or
horizontal left only TXC030D4HPC 30,000 A .067 125/8 x 193/8 301/16 x 141/2 x 211/2 46 3
/4 5
/16
(TXC-E/TXC-S) TXC031D4HPC 30,000 A .067 155/8 x 193/8 301/16 x 171/2 x 211/2 52 3
/4 5
/16
TXC035D4HPC 35,000 A .071 125/8 x 193/8 301/16 x 141/2 x 211/2 46 7
/8 3
/8
TXC036D4HPC 36,000 A .071 155/8 x 193/8 301/16 x 171/2 x 211/2 60 7
/8 3
/8
* TXC series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410A
systems.
RXH ComfortTM Coil Table FUR-23-D — Horizontal Only Cased Coil* R-410A Refrigerant
Features Nom. Cap. Uncrated Line Size
• Sloped non-corrosive Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
drain pan (UL Rated Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
400oF) PHASED
RXH063S3HPB 63,500 OUT
Flat PHASED
TXVNB1 OUT 28PHASED
Full 3
/4 x 101/4 x 371OUT
/2 79PHASED
3
/4 OUT
3
/8
• Bi-directional airflow
• Galvanized case - Table FUR-23-E — Cased Horizontal Only
unpainted Nom. Cap. Duct Con. Uncrated Line Size
• Suction pressure port Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Shipping OD OD
• 5-year limited parts Number (Btuh) Type Control H xW H x W x D Weight (Ibs.) Gas Liq.
warranty TXH025A4HPA 27,000 Flat .057 21 x 24 22 x 10 x 28 40 3
/4 5
/16
PHASED OUT
3 3
TXH033A4HPA 34,000 Flat .057 21 x 24 22 x 10 x 28 46 /4 /8
TXH041A4HPA 44,000 Flat .067 21 x 331/4 22 x 10 x 37 56 7
/8 3
/8
TXH054A4HPA 58,000 Flat .083 21 x 331/4 22 x 10 x 37 64 7
/8 3
/8
TXH063P3HPB 61,000 Flat TXVNB1 27 x 331/4 28 x 10 x 37 79 7
/8 3
/8
1 Start Kits may be required on outdoor unit.
* RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410A
systems.
PHASED OUT
1 – 5 Ton TXA036C4HPC 36,000 A .071 No 191/8 x 161/16 x 199/16 29 7
/8 3
/8
Uncased Coils TXA037C4HPC 36,000 A .071 No 189/16 x 199/16 x 199/16 29 7
/8 3
/8
• 5-year limited parts TXA042C4HPC 42,000 A .080 No 211/4 x 161/16 x 199/16 34 7
/8 3
/8
warranty TXA043C4HPC 42,000 A .080 No 2011/16 x 199/16 x 199/16 32 7
/8 3
/8
• FCCV equipped coils TXA048C4HPC 48,000 A .083 No 255/16 x 161/16 x 199/16 39 11/8 3
/8
compatible with R-22 or TXA049C4HPC 48,000 A .083 No 247/8 x 199/16 x 199/16 37 11/8 3
/8
R-410A refrigerant TXA050C4HPC 48,000 A .083 No 243/8 x 231/16 x 199/16 38 11/8 3
/8
TXA060C5HPC 60,000 A TXV - B No 28 x 199/16 x 199/16 43 11/8 3
/8
TXA061C5HPC 60,000 A TXV - B No 277/16 x 231/16 x 199/16 44 11/8 3
/8
PHASED OUT
CCBA36A4ACD 36,000 A FIXED 125/8 x 193/8 225/8 x 141/2 x 211/2 35 3
/4 5
/16
CCBB30A4ACD 30,000 A FIXED 155/8 x 193/8 175/8 x 171/2 x 211/2 41 3
/4 5
/16
CCBB36A4ACD 36,000 A FIXED 155/8 x 193/8 175/8 x 171/2 x 211/2 41 3
/4 5
/16
CCBB42A4ACD 42,000 A FIXED 155/8 x 193/8 225/8 x 171/2 x 211/2 49 3
/4 3
/8
11/2 – 5 Ton CCBB48A4ACD 48,000 A FIXED 155/8 x 193/8 225/8 x 171/2 x 211/2 54 3
/4 3
/8
Cased & Uncased CCBC48A4ACD 48,000 A FIXED 191/8 x 193/8 225/8 x 21 x 211/2 55 3
/4 3
/8
• Cased and uncased upflow CCBC60A4ACE 60,000 A FIXED 191/8 x 193/8 267/8 x 21 x 211/2 67 7
/8 3
/8
cooling only coils CCBD60A5ACD 60,000 A TXV-B 225/8 x 195/16 301/16 x 241/2 x 211/2 69 7
/8 3
/8
• Brazed fittings (left side)
• Drain fitting (left side) Table FUR-24-C — Brazed Uncased (Upflow Only)
• Fixed orifice flow control Nom. Cap. Uncrated Line Size
(except CCBD60A5ACD, Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
CUBD60A5ACD-TXV-B)
• Shipped vertical upflow CUBA18A4ACD 18,000 A FIXED No 111/2 x 131/16 x 199/16 15 5
/8 5
/16
only CUBA24A4ACD 24,000 A FIXED No 145/8 x 131/16 x 199/16 18 3
/4 5
/16
• Painted coil case CUBA30A4ACD 30,000 A FIXED No 145/8 x 131/16 x 199/16 18 3
/4 5
/16
• Suction pressure service CUBA36A4ACD 36,000 A FIXED No 193/4 x 131/16 x 199/16 18 3
/4 5
/16
port CUBB24A4ACD 24,000 A FIXED No 153/16 x 161/16 x 199/16 23 3
/4 5
/16
PHASED OUT
• 100% foil lined insulation CUBB30A4ACD 30,000 A FIXED No 16 x 161/16 x 199/16 24 3
/4 5
/16
• Split inner and outer doors CUBB36A4ACD 36,000 A FIXED No 16 x 161/16 x 199/16 24 3
/4 5
/16
for easy coil cleaning CUBB42A4ACD 42,000 A FIXED No 191/8 x 161/16 x 199/16 24 3
/4 3
/8
• 5 year limited parts CUBB48A4ACD 48,000 A FIXED No 211/4 x 161/16 x 199/16 29 3
/4 3
/8
warranty CUBC36A4ACD 36,000 A FIXED No 165/16 x 199/16 x 199/16 27 3
/4 5
/16
CUBC42A4ACD 42,000 A FIXED No 189/16 x 199/16 x 199/16 34 3
/4 3
/8
CUBC48A4ACD 48,000 A FIXED No 2011/16 x 199/16 x 199/16 32 3
/4 3
/8
CUBC60A4ACD 60,000 A FIXED No 247/8 x 199/16 x 199/16 31 7
/8 3
/8
CUBD48A4ACD 48,000 A FIXED No 205/8 x 231/16 x 199/16 37 3
/4 3
/8
CUBD60A5ACD 60,000 A TXV-B No 277/16 x 231/16 x 199/16 44 3
/4 3
/8
XT 90 & Coils
Matching Matching Matching Matching
Furnace Cabinet Cased Uncased Furnace Cabinet Cased Uncased
Model Width Coils Coils Model Width Coils Coils
TUX1B040A9H21A 17.5" 2CXCB025A 2CXAB025A TDX1B040A9H31A 17.5" 2CXCB025A 2CXAB025A
TUX1B060A9H31A 17.5" 2CXCB031A 2CXAB031A TDX1B060A9H31A 17.5" 2CXCB031A 2CXAB031A
TUX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A TDX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A
2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A
2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A
2TXCB025A 2TXCB025A
2TXCB031A 2TXCB031A
2TXCB036A 2TXCB036A
2TXCB042A 2TXCB042A
2TXCB048A 2TXCB048A
4CXCB025A 4CXCB025A
4CXCB031A 4CXCB031A
4CXCB036A 4CXCB036A
4CXCB042A 4CXCB042A
4CXCB048A 4CXCB048A
4TXCB025A 4TXCB025A
4TXCB031A 4TXCB031A
4TXCB036A 4TXCB036A
4TXCB042A 4TXCB042A
4TXCB048A 4TXCB048A
TUX1C100A9H41A 21" 2CXCC037A 2CXAC037A TDX1C100A9H41A 21" 2CXCC037A 2CXAC037A
2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A
2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A
2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A
2TXCC037A 2TXCC037A
2TXCC043A 2TXCC043A
2TXCC049A 2TXCC049A
2TXCC054A 2TXCC054A
2TXCC060A 2TXCC060A
4CXCC037A 4CXCC037A
4CXCC043A 4CXCC043A
4CXCC049A 4CXCC049A
4CXCC060A 4CXCC060A
4TXCC037A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A
2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A
2TXCD050A 2TXCD050A
2TXCD061A 2TXCD061A
2TXCD065A 2TXCD065A
4CXCD050A 4CXCD050A
4CXCD061A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
XR 90 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C TDX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C
TUX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C TDX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C
TUX1B080A9421A 17.5" 2TXCB025A TXC025D TDX1B080A9421A 17.5" 2TXCB025A TXC025D
2TXCB031A TXC031D 2TXCB031A TXC031D
2TXCB036A TXC036D 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUX080C960D 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100C948D 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUX100C948D 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDX1C100A9481A 21" 2CXCC043A TXC043C 2CXAC043A TXA043C
TUX1C080A9601A 21" 2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C
TUX1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
2TXCC037A RXC054S 2TXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42 A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUX100C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUX120C960D 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDX1D120A9601A 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C
TUX1D100A9601A 2TXCD050A TXC065S1 2TXCD050A TXC065S1
TUX1D120A9601A 2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
XB 90 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUC040C924B 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDC040C924B 17.5" 2CXCB025A TXC025C TXA025C
TUC060C936B 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDC060C936B 17.5" 2CXCB031A TXC031C TXA031C
TUC080C942B 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDC080C942B 17.5" 2CXCB036A TXC036C TXA036C
2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C TXA042C
2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C TXA048C
2TXCB025A TXC025D 2TXCB025A TXC025D
2TXCB031A TXC031D 2TXCB031A TXC031D
2TXCB036A TXC036D 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUC100C948B 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDC100C948B 21" 2CXCC037A TXC037C TXA037C
2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C TXA043C
2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C TXA049C
2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C TXA060C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42 A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUC100C960B 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDC120C960B 24.5" 2CXCD050A TXC050C TXA060C
TUC120C960B 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C TXA061C
2TXCD050A TXC065S1 2TXCD050A TXC065S1
2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).
XV 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
XL 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUD040R924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040R924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C
TUD060R936K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060R936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C
2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C
2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C
4CXCA018A TXC024D 4CXCA018A TXC024D
4CXCA024A TXC030D 4CXCA024A TXC030D
4TXCA018A TXC035D 4TXCA018A TXC035D
4TXCA024A CCBA18A CUBA18A 4TXCA024A
CCBA24A CUBA24A
CCBA30A CUBA30A
CCBA36A CUBA36A
TUD060R937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060R937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUD080R936K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080R936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUD080R948K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD100R945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUD100R936K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C 2CXCB042A TXC042C 2CXAB042A TXA042C
2CXCB048A TXC048C 2CXAB048A TXA031C 2CXCB048A TXC048C 2CXAB048A TXA048C
2TXCB025A TXC025D TXA036C 2TXCB025A TXC025D
2TXCB031A TXC031D TXA042C 2TXCB031A TXC031D
2TXCB036A TXC036D TXA048C 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUD100R948K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100R948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUD100R960K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100R960F 21" 2CXCC043A TXC043C 2CXAC043A TXA043C
2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C
2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXAC060A TXA050C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUD120R960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120R960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUD140R960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140R960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C
2TXCD050A TXC065S1 2TXCD050A TXC065S1
2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).
XT 80 & Coils
Matching Matching Matching Matching
Furnace Cabinet Cased Height Uncased Height Furnace Cabinet Cased Height Uncased Height
Model Width Coils Inches Coils Inches Model Width Coils Inches Coils Inches
TUD1A040A9H21A 14.5" 2CXCA018A 2CXAA018A
2CXCA024A 2CXAA024A
2TXCA018A
2TXCA024A
2TXCA024A
4CXCA018A
4CXCA024A
4TXCA018A
4TXCA024A
TUD1B060A9H31A 17.5" 2CXCB025A 2CXAB025A TDD1B060A9H31A 17.5" 2CXCB025A 2CXAB025A
TUD1B080A9H31A 17.5" 2CXCB031A 2CXAB031A TDD1B080A9H31A 17.5" 2CXCB031A 2CXAB031A
TUD1B100A9H31A 17.5" 2CXCB036A 2CXAB036A 2CXCB036A 2CXAB036A
2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A
2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A
2TXCB025A 2TXCB025A
2TXCB031A 2TXCB031A
2TXCB036A 2TXCB036A
2TXCB042A 2TXCB042A
2TXCB048A 2TXCB048A
4CXCB025A 4CXCB025A
4CXCB031A 4CXCB031A
4CXCB036A 4CXCB036A
4CXCB042A 4CXCB042A
4CXCB048A 4CXCB048A
4TXCB025A 4TXCB025A
4TXCB031A 4TXCB031A
4TXCB036A 4TXCB036A
4TXCB042A 4TXCB042A
4TXCB048A 4TXCB048A
TUD1C080A9H41A 21" 2CXCC037A 2CXAC037A TDD1C100A 21" 2CXCC037A 2CXAC037A
TUD1C100A9H51A 21" 2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A
2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A
2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A
2TXCC037A 2TXCC037A
2TXCC043A 2TXCC043A
2TXCC049A 2TXCC049A
2TXCC054A 2TXCC054A
2TXCC060A 2TXCC060A
4CXCC037A 4CXCC037A
4CXCC043A 4CXCC043A
4CXCC049A 4CXCC049A
4CXCC060A 4CXCC060A
4TXCC037A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUD1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDD1D120A 24.5" 2CXCD050A 2CXAD050A
TUD1D140A9H51A 24.5" 2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A
2TXCD050A 2TXCD050A
2TXCD061A 2TXCD061A
2TXCD065A 2TXCD065A
4CXCD050A 4CXCD050A
4CXCD061A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
XR 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUD040C924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040C924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C
TUD040C930K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060C936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C
TUD060C924K 14.5" 2TXCA018A TXC030C TXA030C TDD060C936F 14.5" 2TXCA018A TXC030C TXA030C
TUD060C936K 14.5" 2TXCA024A TXC035C TXA035C TDD1A040A9241A 14.5" 2TXCA024A TXC035C TXA035C
TUD1A040A9241A 14.5" 4CXCA018A TXC024D TDD1A060A9241A 14.5" 4CXCA018A TXC024D
TUD1A040A9301A 14.5" 4CXCA024A TXC030D TDD1A060A9361A 14.5" 4CXCA024A TXC030D
TUD1A060A9301A 14.5" 4TXCA018A TXC035D 4TXCA018A TXC035D
TUD1A060A9241A 14.5" 4TXCA024A CCBA18A CUBA18A 4TXCA024A
CCBA24A CUBA24A
CCBA30A CUBA30A
CCBA36A CUBA36A
TUD060C937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060C937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUD080C924K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080C936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUD080C936K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD080C945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUD080C948K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C TDD100C945F 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C
TUD100C936K 17.5" 2CXCB048A TXC048C 2CXAB048A TXA031C TDD1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C
TUD100C945K 17.5" 2TXCB025A TXC025D TXA036C TDD1B080A9361A 17.5" 2TXCB025A TXC025D
TUD1B060A9361A 17.5" 2TXCB031A TXC031D TXA042C TDD1B080A9451A 17.5" 2TXCB031A TXC031D
TUD1B080A9241A 17.5" 2TXCB036A TXC036D TXA048C TDD1B100A9451A 17.5" 2TXCB036A TXC036D
TUD1B080A9361A 17.5" 2TXCB042A TXC031E 2TXCB042A TXC031E
TUD1B080A9481A 17.5" 2TXCB048A TXC036E 2TXCB048A TXC036E
TUD1B100A9361A 17.5" 4CXCB025A TXC031S 4CXCB025A TXC031S
TUD1B100A9451A 17.5" 4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUD080C960K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100C948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUD100C948K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100C954F 21" 2CXCC043A TXC043C 2CXAC043A TXA043C
TUD100C960K 21" 2CXCC049A TXC049C 2CXAC049A TXA049C TDD120C954F 21" 2CXCC049A TXC049C 2CXAC049A TXA049C
TUD120C954K 21" 2CXCC060A TXC060C 2CXAC060A TXA050C TDD1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA050C
TUD1C080A9601A 2TXCC037A TXC037E TDD1C100A9541A 21" 2TXCC037A TXC037E
TUD1C100A9481A 2TXCC043A TXC054E TDD1C120A9541A 21" 2TXCC043A TXC054E
TUD1C100A9601A 2TXCC049A TXC037S 2TXCC049A TXC037S
TUD1C120A9541A 2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUD120C960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120C960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUD140C960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140C960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C
TUD1D100A9721A 2TXCD050A TXC065S1 TDD1D120A9601A 24.5" 2TXCD050A TXC065S1
TUD1D120A9601A 2TXCD061A RXC061S TDD1D140A9601A 24.5" 2TXCD061A RXC061S
TUD1D140A9601A 2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).
Table IDAQ-1-A – Air Handler – 24 Volt TRANE CleanEffects™ Whole House Air
Cleaner
TRANE Uncrated
Model Airflow CleanEffects™ Dimensions(in.) Shipping
Number Range Air Handler Width H xW x D Weight
TFD215ALAH000A 300-1200 211/2 inch 71/2 x 211/2 x 21 42
TFD235ALAH000A 350-1600 231/2 inch 71/2 x 231/2 x 21 44
TFD260ALAH000A 400-2000 26 inch 71/2 x 26 x 21 46
• Three sizes to flush fit TWE/4TEE/4TEP 6-way • “Air-Tite™” Door construction eliminates
convertible Air Handler return. air leaks, improves air quality and keeps
• Four sizes to flush fit bottom of Trane furnaces. operating costs low.
• TFP175, TFM175, TFE175 (171/2") bottom • Gaskets included with the air cleaner.
return model can be used for a “Perfect Fit™” • Built-In Air Sensor Switch senses when air
side return on all furnace models. flows through the power assembly on and
• Air Cleaners designed for flush fit on both sides off automatically;
and rear of equipment cabinet. No “Power On” relay required.
• All service and access is from the front of the air • Air Cleaner furnace models come with a
cleaner. 120 volt power supply.
• Cabinet case versatility provides three levels of • Air Cleaner Air Handler models come with a
air quality. 240 volt power supply or 120 volt power
• All Electronic Air Cleaners are shipped with a 1" supply.
washable metal pre-filter.
Table IDAQ-2-A – Air Handler “Perfect Fit™” Dual Filtration Electronic Air Cleaner System With One (1) Inch Pre-Filter
(120 Volt or 240 volt)
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Voltage Air Handler Width H xW x D Weight 3
Air Opening3
TFE215A9AH3 300-1400 120 211/2 inch 71/2 x 211/2 x 21 45 187/8 x187/8
TFE235A9AH3 300-1800 120 231/2 inch 71/2 x 231/2 x 21 49 207/8 x187/8
TFE260A9AH3 400-2100 120 26 inch 71/2 x 26 x 21 53 237/8 x187/8
TFE215A1AH3 300-1400 240 211/2 inch 71/2 x 211/2 x 21 45 187/8 x187/8
TFE235A1AH3 300-1800 240 231/2 inch 71/2 x 231/2 x 21 49 207/8 x187/8
TFE260A1AH3 400-2100 240 26 inch 71/2 x 26 x 21 53 237/8 x187/8
Table IDAQ-2-B – Furnace “Perfect Fit™” Dual Filtration Electronic Air Cleaner System With One (1) Inch Pre-Filter (120 Volt)
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Voltage Air Handler Width H xW x D Weight 3
Air Opening3
TFE145A9FR3 300-1200 120 141/2 inch1 71/2 x141/2 x 27 44 117/8 x2413/16
TFE175A9FR3 300-1500 120 171/2 inch1 71/2 x 171/2 x 27 48 147/8 x2413/16
TFE210A9FR3 300-2000 120 21 inch2 71/2 x 21 x 27 54 183/8 x2413/16
TFE245A9FR3 400-2200 120 241/2 inch2 71/2 x 241/2 x 27 60 217/8 x2413/16
Table IDAQ-2-C — Accessories: 1" Permanent - Washable Filter (Ordered through Parts)
Replacement Previous Enclosure
Part Number Model Number Description Used With
FLR03831 BAYFTFR14W1A 1" PERMANENT - Washable 14-1/2
FLR03832 BAYFTFR17W1A 1" PERMANENT - Washable 17-1/2
FLR03833 BAYFTFR21W1A 1" PERMANENT - Washable 21
FLR03834 BAYFTFR24W1A 1" PERMANENT - Washable 24-1/2
• Three sizes to flush fit TWE/4TEE/4TEP 6-way • “Air-Tite™” Door construction eliminates
convertible Air Handler return. air leaks, improves air quality and keeps
• Four sizes to flush fit bottom of Trane furnaces. operating costs low.
• Air Cleaners designed for flush fit on both sides • Gaskets included with the air cleaner.
and rear of equipment cabinet.
• All service and access is from the front of the air
cleaner.
Table IDAQ-3-A– Air Handler “Perfect Fit™” High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFM215B0AH0 300-1400 211/2 inch 71/2 x 211/2 x 21 22 187/8 x187/8
TFM235B0AH0 300-1700 231/2 inch 71/2 x 231/2 x 21 24 207/8 x187/8
TFM260B0AH0 400-2100 26 inch 71/2 x 26 x 21 25 237/8 x187/8
Table IDAQ-3-B – Furnace “Perfect Fit™”High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFM145B0FR0 300-1200 141/2 inch1 71/2 x141/2 x 27 18 117/8 x2413/16
TFM175B0FR0 300-1500 171/2 inch1 71/2 x 171/2 x 27 21 147/8 x2413/16
TFM210B0FR0 300-2000 21 inch2 71/2 x 21 x 27 24 183/8 x2413/16
TFM245B0FR0 400-2000 241/2 inch2 71/2 x 241/2 x 27 27 217/8 x2413/16
Table IDAQ-3-C – Downflow Furnace “Perfect Fit™”High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFM14DA0FR0 300-1200 141/2 inch 71/2 x141/2 x 21 17 117/8 x187/8
TFM17DA0FR0 300-1500 171/2 inch 71/2 x 171/2 x 21 19 147/8 x187/8
TFM21DA0FR0 300-2000 21 inch 71/2 x 21 x 21 22 183/8x187/8
TFM24DA0FR0 400-2000 241/2 inch 71/2 x 241/2 x 21 24 217/8 x187/8
Table IDAQ-3-D – Air Handler “Perfect Fit™” Medium Efficiency Air Cleaner With One (1) Inch Pleated Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFP215A0AH1 300-1200 211/2 inch 71/2 x 211/2 x 21 20 187/8 x187/8
TFP235A0AH1 300-1500 231/2 inch 71/2 x 231/2 x 21 22 207/8 x187/8
TFP260A0AH1 400-1800 26 inch 71/2 x 26 x 21 24 237/8 x187/8
Table IDAQ-3-E – Furnace “Perfect Fit™” Medium Efficiency Air Cleaner With One (1) Inch Pleated Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFP145A0FR1 300-1200 141/2 inch1 71/2 x141/2 x 27 17 117/8 x2413/16
TFP175A0FR1 300-1500 171/2 inch1 71/2 x 171/2 x 27 19 147/8 x2413/16
TFP210A0FR1 400-1800 21 inch2 71/2 x 21 x 27 22 183/8 x2413/16
TFP245A0FR1 400-2000 241/2 inch2 71/2 x 241/2 x 27 25 217/8 x2413/16
1 Side return no Transition Required.
2 Side return Transition Required.
3 Actual opening does not include flange.
Side View
Top
of
Cabinet
Side View
Side View
Top
of
Cabinet
Top
of
Cabinet
THUMD500A
• Flow Through Fan Powered Humidifier • Reliable Brass Solenoid Valve w/Stainless
• High Performance Humidifier Delivers up to Steel Valve Seat
18 Gallons per Day • UV Resistant Cabinet and Scale Control
• Automatic Humidifier Control with O.D. Insert
Sensor for up to 50% more Humidity • Saddle Valve
• Front Cover Access for easy replacement of • Polyslate Gray Housing matches Furnace
humidifier pad. Cabinet Color
• Aluminum Humidifier Pad Treated with • Decorative nameplate
Ceramic Clay for Enhanced Pad Perfor- • 120V Power Line Cord
mance
THUMD500A
THUMD200,300A
• Reliable Brass Solenoid Valve w/Stainless
• THUMD300A Bypass delivers up to 17 Steel Valve Seat
Gallons per day • Field Convertible Duct Connection, Left or
• THUMD200A delivers up to 12 Gallons per Right Side
day. • Built in Summer / Winter Damper
• THUMD300A Automatic Humidifier Control • UV Resistant Cabinet and Scale Control
and O.D. Sensor for up to 50% more Insert
Humidity • Saddle Valve
• THUMD200A Manual Humidifier Control • Polyslate Gray Housing matches Furnace
• UV Resistant Cabinet and Scale Control Cabinet Color
Insert • Decorative nameplate
• Front Cover Access for easy replacement of • 120 V Primary
humidifier pad. • 24V Secondary, 10VA
THUMD200A, 300A • Aluminum Humidifier Pad Treated with
Ceramic Clay for Enhanced Pad Perfor-
mance
RETURN AIR
OPTIONAL FLUE
NOT ALL MODELS
SUPPLY AIR
• FreshEffects™ ERV technology for all • 6” and 8” double collar duct connections for
seasons and climates TERVR100 and 200
• Static plate energy transfer core for efficient • 8” round compatible duct connection for
transfer of heat and moisture TERVR300
• Passive defrost - condensate drain not • Closed cell foam gasketing for insulation
required integrity
• Balancing dampers not required • 1” duct board insulation with
• Multi position mounting cleanable foil face
• Percent Timer (PT) control included with • May be installed in conditioned and
ERV for simple, automatic operation unconditioned spaces
• Optional push button control for use with PT • Cabinet / Door color: Trane Polyslate Gray /
control Tarpaulin Gray
• Cam action door latches for quick service • 5 year limited warranty on parts
access • 10 year limited warranty on energy
• Heavy gauge, powder painted steel cabinet transfer core
• Permanently lubricated motor bearings • Optional extended warranty
• Ultra quiet operation provides best-in-class • Ships in horizontal configuration and converts
performance with barely noticeable sound quickly for downflow.
levels. • Complete set of customized electric heaters
• Appliance grade finish of durable powder designed for all models. Features a polarized
paint baked on both sides of the panels. plug for easy installation.
• Exclusive Climatuff® high efficiency • Optional filter rack kits fit inside the unit.
compressor with internal overload protection. Available for 1" or 2" media.
• Aerospace ducted outdoor fan with a high • Non-bleed expansion valves on indoor and
efficiency motor for quiet and reliable outdoor coils.
operation. • Direct drive 2 and 3 speed indoor blower
• Composite Vortica® blower provides better motors.
airflow and less sound while using less • Pressure taps easily accessed and protected
energy. inside compressor compartment.
• Spine Fin™ outdoor coil for long lasting • Easy access liquid line tap inside compressor
performance and durability. compartment.
• Right side electrical service for high and low • Standard operation to 55°F as manufactured.
voltage lines. • Low ambient cooling to 0°F with kit.
• Architecturally integrated louvers and corner
• Rugged steel basepan features deep drawn • UL approved and listed.
guards deliver durable protection, extra
duct connections and emergency drains. • 20 year heat exchanger, 10 year compres-
safety, and great looks.
• Steeply sloped composite drainpan will sor, 10 year outdoor coil, and 5 years other
• Weather Beater Top contoured for great
empty fast and never rust. parts limited warranty.
appearance and reinforced for strength.
(Residential Use Only)
• Optional extended warranty.
Table PC-1-A — 4TCX- XL13c - Convertible Package Cooling - R-410A
Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER Weight MCA Fuse Rating H xW x L
4TCX – 208/230/1/60
4TCX3018A1000A 18,800 13.65/11.20 444 10.1 15 69 36 x 51 x 43
4TCX3024A1000A 24,800 13.30/11.00 444 13.6 20 72 36 x 51 x 43
4TCX3030A1000A 29,800 13.15/11.65 445 21.7 35 72 36 x 51 x 43
4TCX3036A1000A 36,200 13.30/11.00 450 23.2 35 72 36 x 51 x 43
4TCX3042A1000A 43,500 13.05/11.00 523 27.9 45 72 38 x 46 x 61
4TCX3048A1000A 46,500 13.15/11.00 607 31.1 50 72 38 x 46 x 61
4TCX3060A1000A 60,500 13.40/11.05 610 43.3 60 72 40 x 46 x 61
4TCX – 208/230/3/60
4TCX3036A3000A 36,200 13.30/11.00 450 18.2 30 72 36 x 51 x 43
4TCX3048A3000A 46,500 13.14/11.00 607 23.6 35 72 38 x 46 x 61
4TCX3060A3000A 60,500 13.40/11.05 610 31.5 50 72 40 x 46 x 61
4TCX – 460/3/60
4TCX3036A4000A 36,200 13.30/11.00 450 8.7 15 72 36 x 51 x 43
4TCX3048A4000A 46,500 13.15/11.00 607 11.7 15 72 38 x 46 x 61
4TCX3060A4000A 60,500 13.40/11.00 610 19.3 25 79 40 x 46 x 61
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PC-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
• Quiet operation delivers great in-home • Complete set of customized electric heaters
comfort with minimal sound. designed for all models. Features a polarized
• Appliance grade finish of durable powder plug for easy installation.
paint baked on both sides of the panels. • Optional filter rack kits fit inside the unit.
• Exclusive Climatuff® high efficiency Available for 1" or 2" media.
compressor with internal overload protec- • Non-bleed expansion valves on indoor and
tion. outdoor coils.
• High efficiency outdoor fan motor for quiet • Direct drive 2 and 3 speed indoor blower
and reliable operation. motors.
• Composite Vortica® blower provides better • Pressure taps easily accessed and protected
airflow and less sound while using less inside compressor compartment.
energy. • Easy access liquid line tap inside compressor
• Spine Fin™ outdoor coil for long lasting compartment.
performance and durability. • Standard operation to 55°F as manufactured.
• Right side electrical service for high and low • Low ambient cooling to 0°F with kit.
voltage lines. • UL approved and listed.
• Rugged steel basepan features deep drawn • 5 year compressor and 5 years other parts
duct connections and emergency drains. limited warranty. (Residential Use Only)
• All steel louvers and cabinet for rugged, long • Steeply sloped composite drainpan will • Optional extended warranty.
lasting protection. empty fast and never rust.
• Weather Beater Top contoured for great • Ships in horizontal configuration and
appearance and reinforced for strength. converts quickly for downflow.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
4TCX3 4TCC3
Table PC-11-A — Accessories 1½-5 1½-5
BAYADAP050A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 1½-3 1½-3
BAYADAP051A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 1½-3 1½-3
BAYADAP052A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 3½-5 3½-5
BAYADAP053A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 3½-5 3½-5
BAYADAP054A ...... Adapter Curb (Cabinet D) ............................................................................................................................... 3½-5 3½-5
BAYCCHT101A ..... Crankcase Heater (230V) .............................................................................................................................. 1½-2 1½-2
BAYCCHT102A ..... Crankcase Heater (230V) .............................................................................................................................. 2½-5 2½-5
BAYCCHT104A ..... Crankcase Heater (460V) .............................................................................................................................. 3,4,5 3,4,5
BAYCOVR112A ..... 12" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3
BAYCOVR118A ..... 18" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3
BAYCURB050A ..... Flat Roof Curb (Insulated)5 ........................................................................................................................... 1½- 3 1½- 3
BAYCURB051A ..... Flat Roof Curb (Insulated)6 ........................................................................................................................... 3½-5 3½-5
BAYDMPR101A ..... 2-Position Motorized Damper ......................................................................................................................... 1½- 3 1½- 3
BAYDMPR102A ..... 2-Position Motorized Damper ......................................................................................................................... 3½-5 3½-5
BAYECON101A ..... Economizer with Barometric Relief1347 .................................................................................................... 1½- 3 1½- 3
BAYECON102A ..... Economizer with Barometric Relief1347 .................................................................................................... 3½-5 3½-5
BAYECON200A ..... Economizer (Horizontal)137 ........................................................................................................................ 1½- 3 1½- 3
BAYECON201A ..... Economizer (Horizontal)137 ........................................................................................................................ 3½-5 3½-5
BAYENTH100A ..... Enthalpy Control Kit3 ..................................................................................................................................... ✔ ✔
BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ............................................................. ✔ ✔
BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .................................................................................... ✔ ✔
BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................................................................... ✔ ✔
BAYFLTR101A ....... 1-2" Filter Frame1 .......................................................................................................................................... 1½- 3 1½- 3
BAYFLTR201A ....... 1-2" Filter Frame1 .......................................................................................................................................... 3½-4 3½-4
BAYLIFT002BA ..... Lifting Lug Kit ................................................................................................................................................. ✔ ✔
BAYLOAM011A ..... Evaporator Defrost Control Kit ........................................................................................................................ ✔ ✔
BAYLOAM105A ..... Low Ambient Control Kit ................................................................................................................................. ✔ ✔
BAYOSAH001A ..... Manual Fresh Air Damper14 ........................................................................................................................ 1½-3 1½-3
BAYOSAH002A ..... Manual Fresh Air Damper14 ........................................................................................................................ 3½-5 3½-5
BAYQSTK300A ..... Quick Start Kit .............................................................................................................................................. 1 Phase Only 1 Phase Only
BAYSQRD001A ..... 16" Round Duct Adapter9 ............................................................................................................................. 1½-3 1½-3
BAYSQRD002A ..... 18" Round Duct Adapter9 ............................................................................................................................. 1½-5 1½-5
BAYUTIL101A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 1½-3 1½-3
BAYUTIL102A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 3½-5 3½-5
1 Must use filter frame when economizer/fresh air kit is used.
2 Ships knocked down.
3 Dry bulb control standard with economizer.
4 Downflow Only.
5 Full perimeter curb for 4TC*3018-036A.
6 Full perimeter curb for 4TC*3042-060A.
7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.
8 Do not use with programmable thermostats.
9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
0 BAYCOVR112,118A will not cover BAYSQRD002A applications
Table PH-12-A — Supplementary Heaters – Separate power source /power entry required
Model Shipping
Number Description Used With Weight
BAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 4TC*3018-060A1 9
BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 4TC*3024-060A1 10
BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 4TC*3030-060A1 14
BAYHTRV120A 15.00/20.0 kW Heater (208/240V 1PH) 4TC*3048-060A1 14
BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 4TC*3018-060A3 9
BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 4TC*3024-060A3 10
BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 4TC*3030-060A3 14
BAYHTRV320A 15.0/20.0 kW Heater (208/240V 3PH) 4TC*3048-060A3 14
BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 4TC*3018-060A4 9
BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 4TC*3024-060A4 10
BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 4TC*3030-060A4 14
BAYHTRV420A 15.0/20.0 kW Heater (460V 3PH) 4TC*3048-060A4 14
XL1400
PHASED OUT
TCY030G100A 13.00/11.00 30,600 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 382 21.4 30 80 R2
TCY036G100A 14.10/12.00 36,000 29 x 36 x 64 (C) 171/2 x 10 189/16 x 111/16 448 24.8 35 80 R2
TCY042G100A 14.00/11.70 41,500 29 x 36 x 64 (C) 171/2 x 10 189/16 x 111/16 448 26.7 40 80 R2
TCY048G100A 14.40/12.20 49,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 561 32.7 50 84 R2
TCY060G100A 13.00/11.00 61,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 566 46.8 60 84 S
TCP — XE 1200
TCC — XE 1000
PHASED OUT
TCC030F100B 10.00/9.10 29,800 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 354 22.7 35 80 R1
TCC042F100B 10.00/8.60 40,500 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 389 31.2 50 80 R2
TCC048F100B 10.00/9.25 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 37.0 55 84 R2
TCC060F100B 10.00/9.20 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 43.9 70 84 R2
A
B
ECONOMIZER/FILTER
ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H
D
J D 29 MM
35 MM L (1 1/8")
M X
(1 3/8") X
Y
Y CONDENSATE DRAIN
L 19 MM (3/4") FEMALE NPT
K M
DOWNFLOW
HORIZONTAL RETURN OPENING
SUPPLY P
76 MM
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING
PHASED OUT
TCY030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38A
TCY036G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33A
TCY042G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33A
TCY048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 251/4 281/2 20 14 31/2 85/16 30A, 38A, 34A
TCY060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 251/4 281/2 20 14 31/2 85/16 30A, 38A, 34A
PHASED OUT
TCX030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 247/8 171/2 10 3 47/16 30A, 38A
TCX036G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 251/4 171/2 10 3 47/16 30A, 38A
TCX042G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 257/8 171/2 10 3 47/16 30A, 38A
TCX048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 301/4 20 14 31/2 85/16 30A, 38A,34A
TCX060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/16 287/8 20 14 31/2 85/16 30A, 38A,34A
PHASED OUT
TCP030F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 247/8 171/2 10 3 47/16 30A, 38A
TCP036F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 251/4 171/2 10 3 47/16 30A, 38A
TCP042F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 257/8 171/2 10 3 47/16 30A, 38A
TCP048F 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 301/4 20 14 31/2 85/16 30A, 38A,34A
TCP060F 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/16 287/8 20 14 31/2 85/16 30A, 38A,34A
Table PC-15-D — TCC – XE 1000 Dimensional Data - Limited Availability 3 Phase Only, 2006
Model A B C D E F G H J K L M N P BAYCURB0
TCC018F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 251/2 171/2 10 3 47/16 30A, 38A
TCC024F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 251/2 171/2 10 3 47/16 30A, 38A
TCC030F
TCC036F
TCC042F
TCC048F
TCC060F
551/4
551/4
551/4
645/16
645/16
PHASED OUT
36
36
36
45
45
293/16
293/16
293/16
333/8
333/8
189/16
189/16
189/16
211/16
211/16
111/16
111/16
111/16
151/16
151/16
69/16
69/16
69/16
415/16
415/16
613/16
613/16
613/16
91/8
91/8
17
17
17
2115/16
2115/16
203/16
185/8
19
245/8
245/8
255/16
243/16
24
281/2
281/2
171/2
171/2
171/2
20
20
10
10
10
14
14
3
3
3
31/2
31/2
47/16
47/16
47/16
85/16
85/16
30A, 38A
30A, 38A
30A, 38A
30A, 38A, 34A
30A, 38A, 34A
Note: TCC-F models currently manufactured with sloped drain pans.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PC-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
1½ through 5 Tons
T
• Impack Plus™ feature set .............................................................................................................. ✔ ✔ ✔ ✔
U
• Climatuff® Compressor (1) .............................................................................................................. ✔ ✔ ✔ ✔
• Comfort-RTM mode option ............................................................................................................... ✔ — — —
O
• Coil Sav’RTM coil guard ................................................................................................................... ✔ ✔ — —
• Direct drive two-speed fan motor ..................................................................................................... ✔ — — —
✔
ED
• GE ECM variable speed fan motor .................................................................................................. — — —
• Heavy vinyl - coated coil guard ........................................................................................................ — — ✔ —
• Horizontal convertible to downflow .................................................................................................. ✔ ✔ ✔ ✔
• Plate Fin coil .................................................................................................................................... ✔ ✔ ✔ ✔
AS
• Polarized plugs ................................................................................................................................ ✔ ✔ ✔ ✔
• Powder paint .................................................................................................................................... ✔ ✔ ✔ ✔
• 5-year limited compressor only warranty (Commercial use) ............................................................ ✔ ✔ ✔ ✔
PH
• 5-year limited compressor, coil and parts warranty (Residential use) ............................................. — — ✔ ✔
• 5-year limited parts warranty (Residential use) ............................................................................... ✔ ✔ — —
• 1-year limited coil and parts warranty (Commercial use) ................................................................ ✔ ✔ ✔ ✔
• 10-year limited compressor and outdoor coil warranty (Residential use) ........................................ ✔ ✔ — —
T
BAY28X190 ............. Locking Thermostat Cover ................................................................................. ✔ ✔ ✔
U
BAYSTAT0102 ........ Auto 2-Stage Heating/2 Cooling with Economizer ............................................. ✔ ✔ ✔
Zone Sensors Section
See Comfort Controls/
O
BAYSTAT0122 ........ Manual 1-Stage Heating/2 Cooling w/economizer ............................................. ✔ ✔ ✔
BAYSTAT033A ........ Outdoor Thermostat ........................................................................................... ✔ ✔ ✔
ED
BAYSTAT253A ........ Humidity Control ................................................................................................ — — —
BAYSTAT304 ........... Cooling Only with Fan Switch ............................................................................ ✔ ✔ ✔
BAYSTAT305 ........... Heat/Cool Vertical .............................................................................................. ✔ ✔ ✔
✔ ✔ ✔
AS
TAYSENS100A ........ Outdoor Temp. Sensor (with case)4 ..................................................................
TAYSTAT300C ......... XT 300C Prog.,7 Day,A/M 1Htg/1Clg ................................................................ ✔ ✔ ✔
TAYSTAT302C ......... XT 302C Prog.,7 Day,A/M 2Htg/2Clg ................................................................ ✔ ✔ ✔
✔ ✔ ✔
PH
T
BAYCURB033A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 60 5/8 L) ...................... 3-3½ — — —
BAYCURB034A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 43 W x 62 1/16 L) .................... 4-5 4-5 4-5 4-5
BAYCURB038A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 53 1/8 L) ...................... 2-5 2-5 2-5 1½-5
BAYDMPR040A ..... 0-25% Manual Fresh Air Damper14 .............................................................. 2-3½ 2-3½ 2-3½ 1½-3½
OU
BAYDMPR041A ..... 0-25% Manual Fresh Air Damper14 .............................................................. 4-5 4-5 4-5 4-5
BAYDMPR050A ..... Motorized Fresh Air Damper1 ....................................................................... 4-5 4-5 4-5 4-5
BAYDUCT004A ..... 12" Round Duct Adapters (2 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½
BAYDUCT005A ..... 14" Round Duct Adapters (1 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½
BAYECMT002A ..... Extreme Conditions Mounting Kit (Curb Mount) ............................................... 2-5 2-5 2-5 1½-5
BAYECMT003A ..... Extreme Conditions Mounting Kit (Slab or Rack Mount) ................................. 2-5 2-5 2-5 1½-5
BAYECON054B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 2-3½ 2-3½ 2-3½ 1½-3½
BAYECON055B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 4-5 4-5 4-5 4-5
BAYECON073A ..... 0-100% Mod. Economizer – Horizontal135 ................................................... 2-5 2-5 2-5 1½-5
BAYENTH001A ..... Enthalpy Control (Solid State)3 ...................................................................... 2-5 2-5 2-5 1½-5
BAYFLTR012A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 2-2½ 2-3½ 2½-3½ 2½-3½
ED
BAYFLTR013A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 3-3½ — — —
BAYFLTR014A ....... Filter Frame1 (3-10 x 25 x 1" filter not included) ............................................. 4-5 4-5 4-5 4-5
BAYFLTR015A ....... Filter Frame1 (20 x 20 x 1" filter not included) ................................................ — 2-5 2 1½-2
BAYFLTR017A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 2-2½ 2-3½ 2½-3½ 2½-3½
BAYFLTR018A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 3-3½ — — —
BAYFLTR019A ....... Filter Frame1 (2-16 x 25 x 2" filter not included) ............................................. 4-5 4-5 4-5 4-5
BAYGARD016A ..... Condenser Coil Guard ..................................................................................... — — — 1½-2
1
BAYGARD017A ..... Condenser Coil Guard .....................................................................................
BAYGARD018A ..... Condenser Coil Guard .....................................................................................
BAYGARD021A ..... Condenser Coil Guard .....................................................................................
BAYHSMT043A ..... High Static Motor (230/460V) 3/4HP ................................................................
BAYHSMT044A ..... High Static Motor (230/460V) 1HP ...................................................................
—
—
—
—
—
AS —
—
—
2½-3½
4
—
—
—
2½-3½
4-5
3 /2
2½-3
4-5
2½-3½
4-5
BAYHSMT045A ..... High Static Motor (208V) 1HP ......................................................................... — 4 4-5 4-5
BAYHSMT056A ..... High Static Motor (208V) 3/4HP ...................................................................... — 2½-3½ 2½-3½ 2½-3½
BAYINDK001A* ..... Insulated Deck Pan for A & B Cabinet ............................................................. 2-5 2-5 2-5 1½-5
PH
BAYINDK002A** .... Insulated Deck Pan for C Cabinet .................................................................... 2-3½ — — —
BAYINDK003A*** ... Insulated Deck Pan for D Cabinet .................................................................... 4-5 4-5 4-5 4-5
BAYKSKT010A ...... Quick Start Kit (Single Phase Models Only) .................................................... — — — 1½-5
BAYKSKT254 ........ Start Kit - Scroll Models Only(Single Phase Models Only) ............................... — 2½-4 2½-4 —
BAYLIFT002B ........ Lifting Lug Kit .................................................................................................. 2-5 2-5 2-5 1½-5
BAYLOAM011A ..... Evaporator Defrost Control Kit ......................................................................... 2-5 2-5 2-5 1½-5
BAYLOAM323A ..... Dual Voltage Elec. Head Pressure Control (208-230V or 460V)78 .................... 2-5 2-5 2-5 1½-5
BAYMOTR307A ..... 200-230V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) .................. 2-3½ 2-5 2-5 1½-5
BAYMOTR406A ..... 460V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) ......................... — 3-5 3-5 1½-5
BAYRLAY002 ......... Time Delay Relay ............................................................................................ 2-5 2-5 2-5 —
BAYSTAT023 ......... Remote Potentiometer for BAYECON054B, 055B, 073A ................................. 2-5 2-5 2-5 1½-5
BAYUTIL030A ....... Roof Curb Utility Extension Kit for BAYCURB030A, 038A ................................ — — — 1½-5
BAYUTIL033A ....... Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — —
BAYUTIL034A ....... Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — 4-5
1 Must use filter frame when economizer/fresh air kit is used. 7 Low ambient cooling requires crankcase heater.
2 Ships knocked down. 8 May require motor change. (See Installers Guide.)
3 Dry bulb control standard with economizer. 9 Activated on Power On.
4 Downflow Only. * Currently Shipped with BAYCURB038A.
5 2-Stage thermostat provides additional energy savings if ** Currently Shipped with BAYCURB033A.
simultaneous economizer and compressor operation is expected. *** Currently Shipped with BAYCURB034A.
6 Do not use with programmable thermostats.
PHASED OUT
BAYFLTR013A Filter Frame (20x25x1" filer not included) TCM042F
BAYGARD017A Condenser Coil Guard TCM042, 048F
BAYGARD018A Condenser Coil Guard TCM030, 036F
BAYHSMT043A High Static Motor All TCM-F Models
BAYHSMT044A High Static Motor All TCM-F Models
BAYHSMT045A High Static Motor All TCM-F Models
BAYHSMT056A High Static Motor All TCM-F Models
BAYKSKT010A Quick Start Kit All TCM-F Models
PHASED OUT
BAYSTAT305 Heat/Cool Vertical All TCM-F Models
BAYSTAT033A Outdoor Thermostat All TCM-F Models
TCONT200A 1Heat/1Clg All TCM-F Models
TCONT401A 2Heat/1Clg All TCM-F Models
TCONT402A 3Heat/2Clg All TCM-F Models
TCONT600A 1Heat/1Clg All TCM-F Models
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
311mm
[12-1/4]
LEFT SIDE
TCH-B models will be upgraded in
the 1st Quarter of 2006.
For complete equipment / combination
Effective 1/1/06 PC-22 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Over/Under 2 through 5 Tons
RIGHT SIDE
For complete equipment / combination
selections and installation instructions, please PC-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ 3-10 ton
Packaged Cooling
Standard Features:
• Trane built scroll compressors on all 3-10 ton units except 3 ton standard efficiency
model (Reciprocating Compressor)
• Colored and numbered wiring
• Provisions for through the Base Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• 2" throwaway filters provided on 6-10 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22 or R-410A
• IAQ Sloped Drain Pans
• Single point power for Electric Heat
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
Featuring • 5 - year Limited Compressor Warranty
A New Look for a New Century • 1 - year Limited Parts Warranty
Beveled Top Added Flexibility
Smoother Design
Small compact cabinet • Electromechanical or ReliaTel™ controls (See page PC-35 for ReliaTel™
Recessed access handles Control Information)
• Standard or high efficiency cooling models available
• Convertible airflow (ships in downflow application)
• Fork lift openings on three sides of unit
• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time
Table PC-30-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry
Model Power kW Nominal No.
Number Supply Rating BTUH Stages 1
Used With1
BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 T*C036-060(A or E)1
BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 T*C036-060(A or E)1
BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 T*C036-060(A or E)1
BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 T*C048-060(A or E)1
BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 T*C036-060(A or E)3
BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 T*C036-060(A or E)3
BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 T*C036-060(A or E)3
BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 T*C060(A or E)3
BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 T*C072A3,TSC090,092A3
BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 T*C072A3,TSC090,092A3
BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C072A3,TSC090,092A3
BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 T*C072A3,TSC090,092A3
BAYHTRT309A 208/240/3/60 6.75/9.0 23,000/30,700 1 THC092A3,T*C102A3
BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 THC092A3,T*C102,120A3
BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C102,120A3,THC092A
BAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 THC092A3,T*C102,120A3
BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 T*C120A3
Alternating Lead/Lag – Dual Compressor Models Only — Increased Reliability — Fewer components (moving electro-
During periods of part load operation, each compressor cycles mechanical parts), less likelihood of equipment down time or
alternately as circuit number one, equalizing compressor wear and run failure. Standard
time. Enabled by cutting the wire (BLUE) at (RTRM) junction number
J3-8. Standard Integral Electric Heat Staging1 — Stages electric heaters “OFF”
and “ON”, eliminating the use of outdated sequencers. Standard
Anti Short Cycle Timer (ASCT) Function — Provides a three (3)
minute minimum “ON” time and a three (3) minute minimum “OFF” time Intelligent Fallback1 — A built in Default Control provides adaptive
for compressors, enhances compressor reliability by ensuring proper oil operation, which allows the equipment to continue
return. Standard to operate, providing comfort in the event of certain component
failures. Also, allows emergency operation without a Zone Sensor
Built In Evaporator Defrost Control (EDC) Function — Module (ZSM). Standard
Provides low ambient cooling down to 0°F. Standard
Low Ambient Start Timer (LAST) Function — Bypasses low
Built In Fan Delay Relay (FDR) Function — Provides custom indoor pressure control when a compressor starts, eliminating nuisance
fan timing sequences for the different types of equipment, enhancing compressor lock outs. Standard
efficiency and reliability. Standard
Lower Installation Cost — Using a standard Zone Sensor Module
Built In Night Set Back and Unoccupied Functions1 — When using (ZSM), control voltage wiring may be run up to five (5) times further
a standard dual setpoint/auto change over Zone Sensor Module (ZSM), than any electromechanical system, with no increase in wire gauge.
this function is enabled by applying a short across terminal J6-11 and Example: Electromechanical System –
J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint 30 feet maximum using 22 gauge wire. Micro Control System – 150
back a minimum of 7°F, forces outside air damper (if present) minimum feet using 22 gauge wire. Standard
position to zero, and forces fan operation to automatic. Accessory
(requires time clock accessory or field supplied/installed switch or On Board Diagnostics1 — Assist with equipment troubleshooting, if
contacts). a problem occurrence should take place. Standard
Built In “TEST” Mode — Aids in quick verification of system Remote Sensing1 — All standard Zone Sensor Modules
and control operation, exercises both hardware and software (ZSMs) have remote sensing capabilities, typically achieved by using
(no special tools required). Standard an expensive program-mable thermostat and remote sensor with
electromechanical equipment. Accessory (requires use of remote
Built In Unoccupied Mode1 — When using a standard single sensor).
setpoint/manual change over Zone Sensor Module (ZSM), this function
is enabled by applying a short across terminal J6-11 and J6-12. Forces Selectable Economizer Dry Bulb Change Over — Allows the
outside air damper (if present) minimum position to zero, forces fan capability of selecting the following dry bulb change over points:
operation to automatic. Accessory (requires time clock accessory or 63, 67, 70 or 73°F. Standard with economizer accessory.
field supplied/installed switch or contacts.) Space Temperature Averaging1 — All standard Zone Sensor
Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Modules (ZSMs) have space temperature averaging capabilities,
Proportional – sets corrective action proportional to deviation typically achieved by using an expensive programmable thermostat
from setpoint. Integral – fine tunes the rate of corrective action and minimum of four (4) remote sensors with electromechanical
proportional to the error (results in superior space temperature control). equipment. Averaging with ReliaTel™ can be achieved with two
Standard (2) sensors.
Economizer Preferred Cooling1 — Provides fully integrated Supply Air Tempering1 — A built in feature, once enabled only
operation if required. Will not turn on a compressor with the economizer, through an ICS device, may also be enabled using a digital or
if the space is recovering adequately with the economizer alone (0.2°F/ programmable Zone Sensor Module. When in the HEAT mode
minute). Allows the equipment to be utilized in more varied applications. (and not actively heating), if supply air temperature drops 10°F below
Standard with economizer accessory. the heating setpoint, heat is turned on until supply air temperature
rises to a point 10°F above the heating setpoint. Provides temperate
Emergency Stop Terminals On Low Voltage Terminal Board air during the “OFF” cycle, and eliminates
(LTB-5 and LTB-6) — Provides a convenient point to disable the cold air dumping from supply ducts. Extremely effective when
equipment completely, and immediately. Still provides communication to introducing any quantity of fresh air. Standard when using a RTOM,
BAS. Standard ICS device, digital, or programmable Zone Sensor Module.
Heat Pump Smart Recovery and Smart Staging1 — Inhibits Time Delay Relay (TDR) Function — Provides an incremental
auxiliary heat operation if the space is recovering adequately staging delay between compressors, minimizes equipment current
(0.1°F/minute) with the heat pump alone, providing considerable inrush and consumption by keeping compressors from starting
savings in operating costs. Standard simultaneously. Standard
Heat Pump Soft Start — Provides a smooth transition into heating Low Pressure and High Pressure Compressor Lockout — 3 trips
after defrost, minimizing noise and compressor stress associated with will lockout control.
switch over. Standard
Standard Features:
• Trane built scroll compressors on all 3-5 ton units
• Colored and numbered wiring
• Provisions for through the Base Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Single point power for Electric Heat
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
• 5 - year Limited Compressor Warranty
• 1 - year Limited Parts Warranty
Featuring
A New Look for a New Century Added Flexibility
Beveled Top • Electromechanical or ReliaTel™ controls (See page PC-35 for ReliaTel™
Smoother Design Control Information)
Small compact cabinet • Convertible airflow (ships in downflow application)
Recessed access handles • Fork lift openings on three sides of unit
• Belt drive - standard or oversized motors
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time
Table PC-38-B — Base Unit — 13 SEER High Efficiency — ReliaTel™ Microprocessor Controls
Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max1
Tons Ordering No. SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
THC – 208-230/3/60 – Three Phase – No Heat
3 THC033A3R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 30
4 THC043A3R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 35
5 THC063A3R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45
THC – 460/3/60 – Three Phase – No Heat
3 THC033A4R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 15
4 THC043A4R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 15
5 THC063A4R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20
THC – 575/3/60 – Three Phase – No Heat
3 THC033AWR0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 15
4 THC043AWR0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 15
5 THC063AWR0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 15
1 HACR breaker per NEC.
2 Downflow Airflow/Horizontal Airflow.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Enthalpy control not available factory installed with electro-mechanical controls. 9 Return Air Smoke Detector cannot be ordered with Novar Controls.
2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without 0 These options are standard when ordering Novar Controls.
Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must q This options for use when ordering Novar Control only.
be ordered as field installed accessory BAYBARM010A. w Factory Supplied Field Installed.The manual outside air damper will ship factory supplied within the
3 Requires use of Disconnect or Circuit Breaker. unit, but must be field installed.
4 Standard refrigeration metering device - short orifice. e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.
5 Frostat cannot be field installed in electro-mechanical units. r Through the base electric required when ordering Disconnect/Circuit Breaker options.
6 High Pressure control is standard on 3 phase units with scroll compressors. t Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be
7 Not available with BAYFRST001A High Temperature Stat accessory. an option.
8 The return air smoke detector may not fit up or work properly on the Convertible units when used in y Not available with electro-mechanical unit controls.
conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power
exhaust. Do not order the return air smoke detectors when using this type of accessory.
Table PC-40-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry
Model Power kW Nominal No.
Number Supply Rating BTUH Stages Used With
BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 THC033-063A3
BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 THC033-063A3
BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 THC033-063A3
BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 THC063A3
• Weater Beater top contoured and reinforced • Solenoid operated switchover valve
for strength. • Copper tube, aluminum plate fin Indoor coil
• Exclusive Climatuff® high efficiency • Expansion valve no bleed on outdoor coil
compressor • High efficiency outdoor fan motor with
• Aerospace Ducted Outdoor fan for quiet polarized plug
operation • Expansion valve no bleed on indoor coil
• Composite Vortica® Blower uses less • Water shed base
energy to provide more air with less sound. • UL Listed
• Side electrical service access for high and • Crankcase heater
low voltage • Direct drive blower 2-speed motor
• Sloped composite no-rust drain pan • Compressor internal overload protection
• Shipped for horizontal application, easily • Protected pressure taps for refrigerant
convertible to downflow checks
• One electric heater family • Standard operation to 55°F. as manufac-
• Optional filter rack fits inside unit tured
• Low voltage polarized plug for easy electric • Low ambient cooling to 0°F. with
heater installation BAYLOAM105A
• Heavy gauge steel cabinet with weather • 10-year limited compressor
• Architectual Louvers and Corner Guards for resistant, baked enamel finish warranty, 5-year other parts single phase
durable protection and extra safety. • Top discharge fan (Residential Use Only)
• Appliance Grade Finish durable powder paint • Demand defrost control • Optional extended warranties
baked on both sides of every panel. • Refrigerant line filter drier
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PH-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PH-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons
Table PH-12-A — Supplementary Heaters – Separate power source /power entry required
Model Shipping
Number Description Used With Weight
BAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 2/4WC*3018-060A1 9
BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 2/4WC*3024-060A1 10
BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 2/4WC*3030-060A1 14
BAYHTRV120A 15.0/20.0 kW Heater (208/240V 1PH) 2/4WC*3048-060A1 14
BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 2/4WC*3018-060A3 9
BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 2/4WC*3024-060A3 10
BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 2/4WC*3030-060A3 14
BAYHTRV320A 15.00/20.0 kW Heater (208/240V 3PH) 2/4WC*3048-060A3 14
BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 2/4WC*3018-060A4 9
BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 2/4WC*3024-060A4 10
BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 2/4WC*3030-060A4 14
BAYHTRV420A 15.00/20.0 kW Heater (460V 3PH) 2/4WC*3048-060A4 14
WCZ-F – XL 1600
WCY-G – XL 1400
WCX-G – XL 1200
PHASED OUT
WCY030G100B 13.50/11.50 7.70 30,000 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 398 21.4 30 80 R2
WCY036G100B 13.50/11.55 7.95 37,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 27.4 40 80 R2
WCY042G100B 13.05/11.25 7.80 42,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 29.6 45 80 R2
WCY048G100A 13.75/12.00 7.60 49,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 38.1 60 84 R2
WCY060G100A 13.00/11.35 7.80 60,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 574 46.8 60 84 S
PHASED OUT
WCX – 208-230/3/60
WCX036G300B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 17.9 25 80 R2
WCX042G300A 12.10/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 18.8 30 80 R2
WCX048G300A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 27.8 40 84 R2
WCX060G300A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 30.1 45 84 R2
WCX – 460/3/60
WCX036G400B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 9.7 15 80 R2
WCX048G400A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 12.7 15 84 R2
WCX060G400A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 21.1 30 84 R2
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
WCP – XE 1200
WCC – XE 1000
WCP – 208-230/3/60
WCP036F300B
WCP048F300A
WCP060F300A
WCP – 460/3/60
PHASED OUT
12.30/10.90
12.00/10.60
12.00/10.70
7.6
7.6
8.2
38,000
48,000
60,000
29 x 36 x 62 (C)
33 x 45 x 64 (D)
33 x 45 x 64 (D)
10 x 171/2
14 x 20
14 x 20
189/16 x 111/16
211/16 x 151/16
211/16 x 151/16
468
576
576
17.9
27.8
30.1
25
40
45
80
84
84
R2
R2
R2
WCP036F400B 12.30/10.90 7.6 38,000 29 x 36 x 62 (C) 10 x 171/2 189/16 x 111/16 468 9.7 15 80 R2
WCP048F400A 12.00/10.60 7.6 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 12.7 15 84 R2
WCP060F400A 12.00/10.70 8.2 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 17.7 25 84 R2
PHASED OUT
WCC030F100B 10.00/9.50 6.8 29,800 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 359 23.4 40 80 R1/2
WCC036F100B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 383 26.0 40 80 R2
WCC042F100B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 400 31.2 50 80 R2
WCC048F100B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 37.2 60 84 R2
WCC060F100B 10.009.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 41.1 60 84 R2
A
B
ECONOMIZER/FILTER
CORNER POST ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H
CONDENSOR COIL D
J D 29 MM
35 MM L (1 1/8")
M X
(1 3/8") X
Y
Y CONDENSATE DRAIN
L 19 MM (3/4") FEMALE NPT
K M
DOWNFLOW
HORIZONTAL RETURN OPENING
SUPPLY P
76 MM
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING
Table PH-15-E — WCC – XE 1000 Dimensional Data - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.
Model A B C D E F G H J K L M N P BAYCURB0
WCC018F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 201/2 25 171/2 10 3 47/16 30A, 38A
WCC024F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 201/2 25 171/2 10 3 47/16 30A, 38A
PHASED OUT
WCC030F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 2013/16 255/16 171/2 10 3 47/16 30A, 38A
WCC036F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 19 243/16 171/2 10 3 47/16 30A, 38A
WCC042F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 1813/16 24 171/2 10 3 47/16 30A, 38A
WCC048F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 243/4 29 20 14 31/2 85/16 30A, 38A, 34A
WCC060F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 243/4 29 20 14 31/2 85/16 30A, 38A, 34A
Note: WCC-F models currently manufactured with sloped drain pans.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Dual Fuel Heat Pump with
Auxiliary Gas Heat
PHASED OUT
DCY – 208-230/3/60
DCY036F3H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 17.9 25 80 R2
DCY048F3H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 27.8 40 84 R2
DCY060F3M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 30.1 45 84 R2
DCY – 460/3/60
DCY036F4H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 9.7 15 80 R2
DCY048F4H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 12.7 15 84 R2
DCY060F4M0A 58,500 80 or 98 12.00/10.70 80 8.21 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 21.1 30 84 R2
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
PHASED OUT
• DuraTuff™ Plate Fin coil ............................................................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Coil Sav’RTM coil guard ................................................................................................. ✔ ✔ ✔ ✔ — —
T
• Crankcase heater .......................................................................................................... ✔ ✔ ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔ ✔
U
• Deluxe XL Lexan nameplate .......................................................................................... —
• Demand defrost control with Lite Port/Stored diagnostics ............................................. ✔ ✔ ✔ ✔ ✔ ✔
O
• GE ECM variable speed fan w/potted motor module ..................................................... 5 ✔ ✔ 5 5 —
• Horizontal convertible to downflow ................................................................................ ✔ ✔ ✔ ✔ ✔ ✔
ED
• Polarized plugs .............................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔
• Powder paint .................................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔
✔
AS
• Time/temperature defrost .............................................................................................. — — — — —
• Two-stage cooling .......................................................................................................... — ✔ — — — —
• Two-stage heating .......................................................................................................... — ✔ ✔ — — —
PH
• 5-year limited compressor only warranty (Commercial use) .......................................... ✔ ✔ ✔ ✔ ✔ ✔
• 5-year limited heat exchanger warranty (Commercial use) ........................................... ✔ — — — — —
• 5-year limited compressor and coil warranty (Residential use) ..................................... — — — — — ✔
• 5-year limited parts warranty (Residential use) ............................................................. ✔ ✔ ✔ ✔ — —
• 5-year limited parts warranty (Residential use) ............................................................. — — — — — ✔
• 1-year limited coil and parts warranty (Commercial use) .............................................. ✔ ✔ ✔ ✔ ✔ ✔
• 10-year limited compressor and coil warranty (Residential use) ................................... ✔ — — — — —
• 10-year limited compressor and outdoor coil warranty (Residential use) ...................... ✔ ✔ ✔ ✔ — —
• 20-year heat exchanger warranty (Residential use) ...................................................... ✔ — — — — —
T
BAYASCT001A1 ....... Anti-short Cycle Timer ...................................................................... — — — —
Zone Sensors Section
U
BAYSTAT033A ......... Outdoor Thermostat ......................................................................... ✔ ✔ ✔ ✔
BAYSTAT040B3 ...... Prog. Electronic Setback 3 Htg/2 Clg ................................................ ✔ — — —
O
BAYSTAT239A ......... Manual 2-Stage Heating/1 Cooling ................................................... ✔ ✔ ✔ ✔
BAYSTAT240A ......... Manual 2 Heating/1 Cooling with Subbase ........................................ ✔ ✔ ✔ ✔
ED
BAYSTAT253A ......... Humidity Control ............................................................................... — — — —
TAYSENS100A ........ Outdoor Temp. Sensor (with case) .................................................... ✔ ✔ ✔ ✔
AS
T
PHASED OUT
BAYDMPR041A ... 0-25% Manual Fresh Air Damper (Downflow Only)2 ................................ 4-5 5 4-5 4-5 4-5 4-5
BAYDMPR050A ... Motorized Fresh Air Damper ...................................................................... 4-5 — 4-5 4-5 4-5 4-5
BAYDUCT004A ... 12" Round Duct Adapters (2 per Box) ....................................................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2
BAYDUCT005A ... 14" Round Duct Adapters (1 per Box) ....................................................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2
ED OU
BAYECMT002A ... Extreme Conditions Mounting Kit (Curb Mount) ......................................... 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYECMT003A ... Extreme Conditions Mounting Kit (Slab or Rack Mount) ............................. 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYECON054B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2
BAYECON055B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 4-5 5 4 -5 4-5 4-5 4-5
BAYECON073A ... 0-100% Mod. Horizontal Economizer1245 ............................................ 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYENTH001A ... Enthalpy Control (Solid State)4 ................................................................ 2-5 3-5 2-5 3-5 3-5 11/2-5
BAYFLTR012A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... — — 2-21/2 2-21/2 — 21/2-31/2
BAYFLTR013A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... 2-3 3 3-31/2 3-31/2 3 —
BAYFLTR014A ..... Filter Frame2 (3-10 x 25 x 1" filter not included) ........................................ 4-5 5 4-5 4-5 4-5 4-5
BAYFLTR015A ..... Filter Frame2 (20 x 20 x 1" filter not included) ........................................... — — — — — 11/2-2
BAYFLTR017A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ — — 2-21/2 2-21/2 — 21/2-31/2
BAYFLTR018A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ 2-3 3 3-31/2 3-31/2 3 —
BAYFLTR019A ..... Filter Frame2 (2-16 x 25 x 2" filter not included) ........................................ 4-5 5 4 4-5 4-5 4-5
BAYGARD016A ... Condenser Coil Guard ............................................................................... — — — — — 11/2-2
BAYGARD017A ... Condenser Coil Guard ............................................................................... — — — — — 21/2-3
BAYGARD019A ... Condenser Coil Guard ............................................................................... — — — — — 31/2
BAYGARD022A ... Condenser Coil Guard ............................................................................... — — — — — 4-5
BAYHSMT043A ... High Static Motor (230/460) 3/4HP ............................................................ 21/2-3 — — 21/2-31/2 21/2-3 21/2-31/2
BAYHSMT044A ... High Static Motor (230/460) 1HP ............................................................... 4 — — 4 4 4-5
PHAS
PHASED OUT
422mm
[16-5/8]
311mm
[12-1/4]
LEFT SIDE
RIGHT SIDE
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-21 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Over/Under 2 through 5 Tons
Model No. Power Supply kW Ratings Nominal BTUH No. of Stages Used With
BAYHTRC306A 208/240/3/60 4.33/5.76 14,800/19,700 1 WCH036-042B300B
BAYHTRC312A 208/240/3/60 8.65/11.52 29,500/39,300 1 WCH036-042B300B
BAYHTRC317A 208/240/3/60 12.98/17.28 44,300/59,000 1 WCH036-042B300B
WCM
• Climatuff® compressor • Crankcase heater
• High efficiency performance • Protected pressure taps for refrigerant
• Two-speed evaporator blower motor checks
• Round duct connections for manufactured • Heavy gauge steel cabinet with weather
housing applications resistant, baked enamel finish
• Quiet operating top condenser air discharge • Fully insulated air handling compartment
• Copper tube/aluminum fin coils • Convenient access panels
• Totally enclosed, permanently lubricated • 5-year limited compressor and coil warranty
condenser fan motor (Residental)
• Hermetically sealed compressor with • 5-year limited parts warranty
internal relief valve (Residental)
• Fully charged R-22 system • 5-year compressor only limited warranty
• Sloped Drain Pan (Commercial)
• Liquid line filter-drier • 1-year limited parts warranty (Commercial)
• Heating expansion device/cooling FCCV
Table PH-23-A — Mobile Home Heat Pumps (208-230/1/60)
Unit Cooling Dimensions Round Round Shipping
Model Capacity (in.) Supply Return Weight Max Sound
No. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) MCA* Fuse* Rating Comp.
PHASED OUT
WCM030F100B 10.0/9.50 29,800 29 x 36 x 55 (B) 12 12 376 23.4 35 80 R1
WCM036F100B 10.0/9.50 36,000 29 x 36 x 55 (B) 12 12 406 26.0 40 80 R2
WCM042F100B 10.09.20 41,500 29 x 36 x 55 (B) 14 14 416 31.8 50 80 R2
PHASED OUT
BAYHTRN108A 5.76/7.68 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN110A 7.47/9.96 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN112A 8.65/11.52 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN115A 11.21/14.94 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN117A 12.98/17.28 kW Heater (208/240 volts) All WCM-F Models
Standard Features:
• Trane built scroll compressors on all 4-10 ton units. 3 ton unit has a Reciprocating
Compressor
• ReliaTel™ Controls (See page PC-35 for ReliaTel™ Control Information)
• Colored and numbered wiring
• Provisions for through the Base Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• 2" throwaway filters provided on 6-10 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Single point power for electric Heat
• Low Ambient cooling to 0°F
Featuring • 5 - year Limited Compressor Warranty
A New Look for a New Century • 1 - year Limited Parts Warranty
Beveled Top Added Flexibility
Smoother Design • Convertible airflow
Small compact cabinet • Fork lift openings on three sides of unit
Recessed access handles • Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time
Table PH-27-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry
Model Power kW Nominal No.
Number Supply Rating BTUH Stages 1
Used With1
BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 WSC036-060(A or E)1
BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 WS036-060(A or E)1
BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 WSC036-060(A or E)1
BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 WSC048-060(A or E)1
BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 WSC036-060(A or E)3
BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 WSC036-060(A or E)3
BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 WSC036-060(A or E)3
BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 WSC060(A or E)3
BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 WSC072-090A3
BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC072-090A3
BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC072-090A3
BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC072-090A3
BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC120A3
BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC120A3
BAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC120A3
BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WSC120A3
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 2 through 5 Tons
• Weather Beater Top contoured for great • Complete set of customized electric
appearance and reinforced for strength. heaters designed for all models. Features
• Appliance grade finish of durable powder a polarized plug for easy installation.
paint baked on both sides of the panels. • Optional filter rack kits fit inside the unit.
• Exclusive Climatuff® high efficiency Available for 1" or 2" media.
compressor with internal overload • Non-bleed expansion valves on indoor
protection. and outdoor coils.
• High efficiency outdoor fan motor for quiet • Direct drive 2 and 3 speed indoor blower
and reliable operation. motors.
• Composite Vortica® blower provides • Pressure taps easily accessed and
better airflow and less sound while using protected inside compressor compart-
less energy. ment.
• Spine Fin™ outdoor coil for long lasting • Easy access liquid line tap inside
performance and durability. compressor compartment.
• Right side electrical service for high and • Standard operation to 55°F as manufac-
low voltage lines. tured.
• Rugged steel basepan features deep • Low ambient cooling to 0°F with kit.
• All steel louvers and cabinet for rugged, drawn duct connections and emergency • UL approved and listed.
long lasting protection. drains. • 10 year heat exchanger, 5 year
• Stainless steel burners and heat exchanger • Steeply sloped composite drainpan will compressor and coil and 5 year other
for extra long life and safety. empty fast and never rust. parts limited warranty.
• Quiet operation delivers great in-home • Ships in horizontal configuration and (Residential Use Only)
comfort with minimal sound. converts quickly for downflow. • Optional extended warranty.
Table PG-7-A — 2YCC - XB13c - Convertible Package Gas/Electric - R-22
Cabinet
Model AFUE (%) Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
2YCC – 208/230/1/60
2YCC3024A1040A 23,000 13.00/11.00 80 470 13.3 20 74 36 x 49 x 41
2YCC3024A1064A 23,000 13.00/11.00 80 481 13.3 20 74 36 x 49 x 41
2YCC3030A1040A 28,000 13.00/11.00 80 470 16.3 25 74 36 x 49 x 41
2YCC3030A1064A 28,000 13.00/11.00 80 481 16.3 25 74 36 x 49 x 41
2YCC3030A1075A 28,000 13.00/11.00 79.4 481 16.3 25 74 36 x 49 x 41
2YCC3036A1064A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 41
2YCC3036A1075A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 41
2YCC3036A1096A 35,000 13.00/11.00 80 485 23.0 35 76 36 x 49 x 41
2YCC3042A1064A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 44
2YCC3042A1075A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 44
2YCC3042A1096A 40,000 12.20/11.00 80 607 24.5 40 78 38 x 59 x 44
2YCC3048A1075A 47,000 13.00/11.00 80 656 29.0 45 77 38 x 59 x 44
2YCC3048A1096A 47,000 13.00/11.00 80 663 29.0 45 77 38 x 59 x 44
2YCC3048A1120A 47,000 13.00/11.00 80 669 29.0 45 77 38 x 59 x 44
2YCC3060A1096A 58,000 13.00/11.00 80 678 40.4 60 76 42 x 59 x 44
2YCC3060A1120A 58,000 13.00/11.00 80 684 40.4 60 76 42 x 59 x 44
• Weather Beater Top contoured for great • Complete set of customized electric
appearance and reinforced for strength. heaters designed for all models.
• Appliance grade finish of durable powder Features a polarized plug for easy
paint baked on both sides of the panels. installation.
• Exclusive Climatuff® high efficiency • Optional filter rack kits fit inside the unit.
compressor with internal overload Available for 1" or 2" media.
protection. • Non-bleed expansion valves on indoor
• High efficiency outdoor fan motor for quiet and outdoor coils.
and reliable operation. • Direct drive 2 and 3 speed indoor blower
• Composite Vortica® blower provides motors.
better airflow and less sound while using • Pressure taps easily accessed and
less energy. protected inside compressor compart-
• Spine Fin™ outdoor coil for long lasting ment.
performance and durability. • Easy access liquid line tap inside
• Right side electrical service for high and compressor compartment.
low voltage lines. • Standard operation to 55°F as manufac-
• Rugged steel basepan features deep tured.
• All steel louvers and cabinet for rugged, drawn duct connections and emergency • Low ambient cooling to 0°F with kit.
long lasting protection. drains. • UL approved and listed.
• Stainless steel burners and heat exchanger • Steeply sloped composite drainpan will • 10 year heat exchanger, 5 year
for extra long life and safety. empty fast and never rust. compressor and coil and 5 year other
• Quiet operation delivers great in-home • Ships in horizontal configuration and parts limited warranty.
comfort with minimal sound. converts quickly for downflow. (Residential Use Only)
• Optional extended warranty.
Table PG-8-A — 4YCC - XB13c - Convertible Package Gas/Electric - R-410A
Cabinet
Model AFUE (%) Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
4YCC – 208/230/1/60
4YCC3018A1040A 18,000 13.00/11.00 79.8 471 10.1 15 74 36 x 49 x 41
4YCC3036A1064A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 41
4YCC3036A1075A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 41
4YCC3036A1096A 35,000 13.00/11.00 80 493 23.6 35 75 36 x 49 x 41
4YCC3048A1075A 46,500 13.00/11.00 80 645 31.5 50 80 38 x 59 x 44
4YCC3048A1096A 46,500 13.00/11.00 80 653 31.5 50 80 38 x 59 x 44
4YCC3048A1120A 46,500 13.00/11.00 80 659 31.5 50 80 38 x 59 x 44
4YCC3060A1096A 58,000 13.00/10.95 80 670 43.3 60 79 40 x 59 x 44
4YCC3060A1120A 58,000 13.00/10.95 80 676 43.3 60 79 40 x 59 x 44
4YCC – 208/230/3/60
4YCC3036A3064A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 41
4YCC3036A3075A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 41
4YCC3036A3096A 35,000 13.00/11.00 80 493 18.5 30 75 36 x 49 x 41
4YCC3048A3075A 46,500 13.00/11.00 80 645 24.0 35 80 38 x 59 x 44
4YCC3048A3096A 46,500 13.00/11.00 80 653 24.0 35 80 38 x 59 x 44
4YCC3048A3120A 46,500 13.00/11.00 80 659 24.0 35 80 38 x 59 x 44
4YCC3060A3096A 58,000 13.00/10.95 80 670 31.5 50 79 40 x 59 x 44
4YCC3060A3120A 58,000 13.00/10.95 80 676 31.5 50 79 40 x 59 x 44
4YCC – 460/3/60
4YCC3036A4064A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 41
4YCC3036A4075A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 41
4YCC3036A4096A 35,000 13.00/11.00 80 493 8.7 15 75 36 x 49 x 41
4YCC3048A4075A 46,500 13.00/11.00 80 645 11.7 15 80 38 x 59 x 44
4YCC3048A4096A 46,500 13.00/11.00 80 653 11.7 15 80 38 x 59 x 44
4YCC3048A4120A 46,500 13.00/11.00 80 659 11.7 15 80 38 x 59 x 44
4YCC3060A4096A 58,000 13.00/10.95 80 678 19.3 25 79 40 x 59 x 44
4YCC3060A4120A 58,000 13.00/10.95 80 684 19.3 25 79 40 x 59 x 44
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons
37,000 60,000-76,000
80
80
80
33 x 45 x 65 (D)
33 x 45 x 65 (D)
14 x 20
14 x 20
29 x 36 x 64 (B/C) 10 x 171/2
211/16 x 151/16
211/16 x 151/16
189/16 x 111/16
582
609
440
24.5
30.6
10.0
35
45
15
84
84
80
S
S
S
YCX048G4H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 15.4 20 84 S
YCX060G4M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 15.1 20 84 S
T
YCP030F1M0A 12.00/10.90 30,000 44,000 – 56,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 403 21.2 30 80 S
YCP036F1L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 24.4 40 80 S
YCP036F1M0A 12.0010.50
YCP036F1H0A 12.00/10.50
YCP042F1M0A 12.00/10.55
YCP048F1H0A 12.20/11.45
OU
36,000
36,000
42,000
47,000
48,000 – 57,000
60,000 – 76,000
60,000 – 76,000
78,000 – 95,000
80
80
80
80
29 x 36 x 56 (B/C)
29 x 36 x 64 (B/C)
29 x 36 x 64 (B/C)
33 x 45 x 65 (D)
10 x 171/2
10 x 171/2
10 x 171/2
14 x 20
189/16 x 111/16
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
419
440
454
582
24.4
24.4
26.8
31.9
40
40
40
50
80
80
80
84
S
S
S
S
YCP060F1M0A 12.00/10.55
YCP – 208-230/3/60
S
YCP036F3L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 17.4 25 80 S
YCP036F3M0A 12.00/10.50 36,000 48,000 – 57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 17.4 25 80 S
YCP036F3H0A 12.00/10.50
YCP042F3M0A 12.00/10.55
YCP048F3H0A 12.20/11.45
HA 36,000
42,000
47,000
60,000 – 76,000
60,000 – 76,000
78,000 – 95,000
80
80
80
29 x 36 x 64 (B/C)
29 x 36 x 64 (B/C)
33 x 45 x 65 (D)
10 x 171/2
10 x 171/2
14 x 20
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
440
454
582
17.4
19.9
24.5
25
30
35
80
80
84
S
S
S
YCP060F3M0A 12.00/10.55
YCP – 460/3/60
YCP036F4H0A 12.00/10.50
YCP048F4H0A 12.20/11.45
YCP060F4M0A 12.00/10.55
P 60,000 80,000 – 97,000
29 x 36 x 64 (B/C) 10 x 171/2
33 x 45 x 65 (D) 14 x 20
33 x 45 x 65 (D) 14 x 20
211/16 x 151/16
189/16 x 111/16
211/16 x 151/16
211/16 x 151/16
609
440
582
609
30.6
10.0
15.4
15.1
45
15
20
20
84
80
84
84
S
S
S
S
1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
For information on Roof Curbs and Roof Curb Adaptors,
please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PG-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons
YCC – XE 1000
PHASED OUT
YCC036F1L0B 10.00/8.75 35,200 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 420 25.2 40 80 R1/2
YCC036F1M0B 10.00/8.75 35,200 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 426 25.2 40 80 R1/2
YCC036F1H0B 10.00/8.75 35,200 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 25.2 40 80 R1/2
YCC042F1M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 171/2 189/16 x 111/16 454 30.2 50 80 R2
YCC048F1M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 171/2 189/16 x 111/16 461 33 50 80 R2
YCC048F1H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 34.4 50 84 R2
YCC060F1M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 43.9 70 84 R2
T
• Comfort "R"™ mode option ....................................................................................................... ✔ ✔ — — —
• Aluminized steel tubular heat exchanger ..................................................................................... ✔ ✔ ✔ ✔ ✔
OU
• Direct spark ignition ..................................................................................................................... ✔ ✔ ✔ ✔ ✔
• Dual firing rates (w/optional accessory) ...................................................................................... — — ✔ ✔ ✔
• GE ECM variable speed fan ........................................................................................................ ✔ ✔ — — —
• Heavy Vinyl - coated coil guard ................................................................................................... — — — ✔ —
ED
• Horizontal convertible to downflow .............................................................................................. ✔ ✔ ✔ ✔ ✔
• Lite Port/Stored diagnostics ......................................................................................................... ✔ ✔ ✔ ✔ ✔
• L.P. convertible ............................................................................................................................. ✔ ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔ ✔
AS
• Meets California NOX (as shipped) .............................................................................................
• Multi-port in-shot burner .............................................................................................................. ✔ ✔ ✔ ✔ ✔
• Plate Fin coils .............................................................................................................................. ✔ ✔ ✔ ✔ ✔
• Two-stage cooling ........................................................................................................................ ✔ — — — —
PH
• Two-stage gas valve .................................................................................................................... ✔ ✔ — — —
• 5-year limited compressor only warranty (Commercial use) ........................................................ ✔ ✔ ✔ ✔ ✔
• 5-year limited compressor and outdoor coil warranty (Residential use) ...................................... — — — ✔ ✔
• 5-year limited heat exchanger warranty (Commercial use) ......................................................... ✔ ✔ ✔ ✔ ✔
• 5-year limited parts warranty (Residential use) ........................................................................... ✔ ✔ ✔ ✔ ✔
• 1-year limited parts warranty (Commercial use) .......................................................................... ✔ ✔ ✔ ✔ ✔
• 10-year limited compressor and outdoor coil warranty (Residential use) .................................... ✔ ✔ ✔ — —
• 10-year limited heat exchanger warranty (Residential use) ......................................................... — — — ✔ ✔
• 20-year limited heat exchanger warranty (Residential use) ......................................................... ✔ ✔ ✔ — —
Table PG-17-B — Comfort Controls
AY28X092 ............. Heat/Cool (Horizontal) ...................................................................................... ✔ ✔ ✔
BAY28X1821 ....... 1-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔
BAY28X1831 ...... 2-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔
BAY28X184 ........... Subbase Auto/Manual Changeover .................................................................. ✔ ✔ ✔
BAY28X187 ........... Subbase Auto Changeover ............................................................................... ✔ ✔ ✔
BAY28X190 ........... Locking Thermostat Cover for Room Thermostat .............................................. ✔ ✔ ✔
BAYBASE006A ...... Used w/BAYSTAT040B, 2 Htg / 2 Clg w/Economizer ........................................ ✔ ✔ ✔
T
BAYBASE008A ...... Used w/BAYSTAT040B, 1 Htg / 1 Clg ............................................................... ✔ ✔ ✔
OU
BAYCOVR100A ..... Wall Cover Plate ............................................................................................... ✔ ✔ ✔
BAYSTAT008 ......... Manual 1-Stage Htg/Clg ................................................................................... ✔ ✔ ✔
BAYSTAT010 ......... Auto 2-Stage Heating/Cooling .......................................................................... ✔ ✔ ✔
Zone Sensors Section
PHASED OUT
BAYDMPR041A ..... 0-25% Manual Fresh Air Damper (Downflow Only)2 ...................................... 4-5 4-5 4-5 4-5 4H-5M
BAYDMPR050A ..... Motorized Fresh Air Damper ............................................................................ — — 4H-5M 4H-5M 4H-5M
BAYDUCT004A ...... 12" Round Duct Adapters (2 per Box) Horizontal Only ..................................... 3 2-3½ 2-3½ 2-3½ 1½-4M
BAYDUCT005A ...... 14" Round Duct Adapters (1 per Box) Horizontal Only ..................................... 4 2-3½ 2-3½ 2-3½ 1½-4M
BAYECMT002A ...... Extreme Conditions Mouniting Kit (Curb Mount) .............................................. 3-5 2-5 2-5 2-5 1½-5
BAYECMT003A ...... Extreme Conditions Mouniting Kit (Slab or Rack Mount) ................................. 3-5 2-5 2-5 2-5 1½-5
BAYECON054B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ............................ 3 2-3½ 2-3½ 2-3½ 1½-4M
BAYECON055B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ........................... 4-5 4-5 4-5 4-5 4H, 5M
BAYECON073A ...... 0-100% Mod. Economizer – Horizontal246 .................................................. 3-5 2-5 2-5 2-5 1½-5
BAYENTH001A ...... Enthalpy Control (Solid State)4 ...................................................................... 3-5 2-5 2-5 2-5 1½-5
BAYFLTR012A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LM
BAYFLTR013A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4M
BAYFLTR014A ....... Filter Frame2 (3-10 x 25 x 1" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5M
BAYFLTR015A ....... Filter Frame2 (20 x 20 x 1" filter not included) ................................................ — — 2L 2L 1½-2½L
BAYFLTR017A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LM
BAYFLTR018A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H-3½-4M
BAYFLTR019A ....... Filter Frame2 (2-16 x 25 x 2" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5M
BAYGARD016A ...... Condenser Coil Guard ..................................................................................... — — — — 1½-2½L
BAYGARD017A ...... Condenser Coil Guard ..................................................................................... — — — — 3½-4M
BAYGARD018A ...... Condenser Coil Guard ..................................................................................... — — — — 2½M-3H
BAYGARD021A ...... Condenser Coil Guard ..................................................................................... — — — — 4H-5M
BAYHSMT043A ...... High Static Motor (230/460V) 3/4HP ................................................................ — — 2½-3½ 2½-3½ 2½-3½
BAYHSMT044A ...... High Static Motor (230/460V) 1HP ................................................................... — — 4-5 4-5 4-5
BAYHSMT045A ...... High Static Motor (208V) 1HP .......................................................................... — — 4-5 4-5 4-5
BAYHSMT056A ...... High Static Motor (208V) 3/4HP ....................................................................... — — 2½-3½ 2½-3½ 2½-3½
BAYINDK001A* ...... Insulated Deck Pan for A & B Cabinet .............................................................. — — 2-3LM 2-3LM 1½-3LM
BAYINDK002A** ..... Insulated Deck Pan for C Cabinet .................................................................... 3M 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4M
BAYINDK003A*** ... Insulated Deck Pan for D Cabinet .................................................................... 4H-5M 4H-5M 4H-5M 4H-5M 4H-5M
BAYKSKT010A ....... Quick Start Kit for (Single Phase Units) ........................................................... — — — — 1½-5
BAYKSKT254 ......... Start Kit-Scroll Models Only (Single Phase Only) ............................................ — — 2½-4 2½-4 —
BAYLIFT002B ......... Lifting Lug Kit .................................................................................................. 3-5 2-5 2-5 2-5 1½-5
BAYLOAM011A ...... Evaporator Defrost Control Kit1 ....................................................................... 3-5 2-5 2-5 2-5 1½-5
BAYLOAM323A ...... Head Pressure Control15 ............................................................................... — 2-5 2-5 2-5 1½-5
BAYLOFR001B ...... Low Fire Kit ...................................................................................................... — — 1½-3L 1½-3L 1½-3L
BAYLOFR002B ...... Low Fire Kit ...................................................................................................... — — 2M 2M 2M
BAYLOFR003B ...... Low Fire Kit ...................................................................................................... — — 2½-3M 2½-3M 2½-3M
BAYLOFR004B ...... Low Fire Kit ...................................................................................................... — — 3H,3½M 3H,3½M 3H,3½M-4M
BAYLOFR005B ...... Low Fire Kit ...................................................................................................... — — — — —
BAYLOFR006B ...... Low Fire Kit ...................................................................................................... — — 4-5 4-5 —
BAYLOFR007B ...... Low Fire Kit ...................................................................................................... — — — — 4-5M, 4H
BAYLPKT022A ....... LP Conversion Kit ............................................................................................ — — 2-5 2-5 1½-5
BAYLPKT024C ....... LP Conversion Kit ............................................................................................ 3-5 2-5 — — —
BAYLPSS001A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. — — 2-5 2-5 1½-5
and 5 LP #54 orifices (Single Stage)
BAYLPSS002A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. 3-5 2-5 — — —
and 5 LP #54 orifices (Two Stage)
BAYMOTR307A ...... 208-230V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A .............................. — 2-5 2-5 2-5 1½-5
BAYMOTR406A ...... 460V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A ............................ — — 2-5 2-5 1½-5
BAYOSAC001A ...... Outside Air Econo Controller ............................................................................ 3-5 — — — —
BAYSTAT023 .......... Remote Potentiometer for BAYECON054B, 055B ............................................ 3-5 2-5 2-5 2-5 1½-5
BAYUTIL030A ........ Roof Curb Utility Extension Kit for BAYCURB030, 038A .................................. — — — — 1½-5
BAYUTIL033A ........ Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — — 3H,3½-4M
BAYUTIL034A ........ Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — — 4H, 5M
1 Low ambient cooling requires crankcase heater. 7 Activated on Power Off.
2 Must use filter frame when economizer/fresh air kit is used. 8 Not for use with programmable thermostat. For information on Roof Curbs
3 Ships knocked down. * Currently Shipped with BAYCURB038A.
4 Dry bulb control standard with economizer. ** Currently Shipped with BAYCURB033A. and Roof Curb Adaptors, please
5 May require motor change, see instruction guide. *** Currently Shipped with BAYCURB034A. refer to the Accessories/
6 2-Stage thermostat provides additional energy savings if simultaneous economizer L – Low heat model
Information Tab.
and compressor operation is expected. M – Medium heat model
H – High heat model
For complete equipment / combination
Effective 1/1/06 PG-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 2 through 5 Tons
A
B
ECONOMIZER/FILTER
ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H 67 MM (2 5/8")
59 MM (2 5/16")
D
J D 48 MM (1 7/8") DIA. ENTRY
35 MM L FOR 13 MM (1/2) NPT
X
(1 3/8") M X GAS CONNECTION
Y 29 MM
Y (1 1/8")
L CONDENSATE DRAIN
K M 19 MM (3/4") FEMALE NPT
HORIZONTAL DOWNFLOW
SUPPLY P
76 MM RETURN OPENING
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING
PHASED OUT
YCX036G-L 561/2 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38A
YCX024G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 211/2 23 171/2 10 3 83/4 30A, 38A
YCX030G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 201/2 25 171/2 10 3 83/4 30A, 38A
YCX036G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 191/2 2715/16 171/2 10 3 83/4 30A, 38A
YCX036G-H 64 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCX042G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCX048G-H 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A
YCX060G-M 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A
A
B
ECONOMIZER/FILTER
ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H 67 MM (2 5/8")
59 MM (2 5/16")
D
J D 48 MM (1 7/8") DIA. ENTRY
35 MM L FOR 13 MM (1/2) NPT
M X
(1 3/8") X GAS CONNECTION
Y 29 MM
Y (1 1/8")
L CONDENSATE DRAIN
K M 19 MM (3/4") FEMALE NPT
HORIZONTAL DOWNFLOW
SUPPLY P
76 MM RETURN OPENING
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING
PHASED OUT
YCP030F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38A
YCP036F-L 56½ 36 293/16 189/16 111/16 69/16 613/16 17 20½ 251/8 171/2 10 3 47/16 30A, 38A
YCP036F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 20½ 251/8 171/2 10 3 47/16 30A, 38A
YCP036F-H 64 36 293/16 189/16 111/16 69/16 111/8 17 20½ 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCP042F-M 64 36 293/16 189/16 111/16 69/16 111/8 17 20½ 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCP048F-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 30¼ 20 14 31/2 815/16 30A, 38A, 34A
YCP060F-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 287/8 20 14 31/2 815/16 30A, 38A, 34A
PHASED OUT
YCC036F-L 551/4 36 293/16 189/16 111/16 69/16 613/16 17 203/4 2513/16 171/2 10 3 47/16 30A, 38A
YCC030F-M 551/4 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38A
YCC036F-M 551/4 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38A
YCC036F-H 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCC042F-M 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCC048F-M 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCC048F-H 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A
YCC060F-M 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A
Standard Features:
• Trane built scroll compressors on all 3-10 ton units except 3 ton standard efficiency
model (Reciprocating Compressor)
• Colored and numbered wiring
• Provisions for through the Base Gas and Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• 2" throwaway filters provided on 6-10 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
• 5 - year Limited Compressor Warranty
Featuring • 5 - year Limited Heat Exchanger Warranty
A New Look for a New Century • 1 - year Limited Parts Warranty
Beveled Top
Smoother Design Added Flexibility
Small compact cabinet
• Electromechanical or microprocessor controls (See page PC-35 for ReliaTel™
Recessed access handles
Control Information)
• Standard or high efficiency cooling models available
• Low, medium or high heat, single or two stage
• Convertible airflow
• Fork lift openings on three sides of unit
• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time
1 Enthalpy control not available factory installed with electro-mechanical controls. 9 Return Air Smoke Detector cannot be ordered with Novar Controls.
2 Economizer with Barometric Relief is for downfllow configured units only. Order 0 These options are standard when ordering Novar Controls.
Economizer without Barometric Relief for horizontal configuration. Barometric relief for q This option is used when ordering Novar Controls.
horizontal configured units must be ordered as field installed accessory BAYBARM010A. w Includes gas piping and shutoff (field assembly required).
3 Requires use of Disconnect or Circuit Breaker. e The manual outside air damper will ship factory supplied within the unit, but must be field
4 Standard refrigeration metering device - short orifice. installed.
5 Frostat cannot be field installed in electro-mechanical units. r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.
6 High Pressure control is standard on 3 phase units with scroll compressors and in t Through the base electric required when ordering disconnect/circuit breaker options.
YSC036A. y Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models phase
7 Not available with BAYFRST001A High Temperature Stat accessory. monitor will be an option.
7 The return air smoke detector may not fit up or work properly on the Precedent units u Not available with electro-mechanical controls.
when used in conjunction with 3rd party accessories such as bolt on heat wheels,
economizers and power exhaust. Do not order the return air smoke detectors when
using this type of accessory.
Standard Features:
• Trane built scroll compressors on all 3-5 ton units
• Colored and numbered wiring
• Provisions for through the Base Gas and Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
• 5 - year Limited Compressor Warranty
• 5 - year Limited Heat Exchanger Warranty
• 1 - year Limited Parts Warranty
Featuring
A New Look for a New Century
Added Flexibility
Beveled Top
Smoother Design • Electromechanical or microprocessor controls (See page PC-35 for ReliaTel™
Small compact cabinet Control Information)
• Low, medium or high heat, single or two stage
Recessed access handles
• Convertible airflow
• Fork lift openings on three sides of unit
• Belt drive - standard or oversized motors
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time
Table PG-39-A — Base Unit — 13 SEER High Efficiency — ReliaTel™ Microprocessor Controls
1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YHC –208-230/3/60 – Three Phase – Low Heat
3 YHC033A3RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – Low Heat
3 YHC033A4RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – Low Heat
3 YHC033AWRLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWRLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWRLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
YHC –208-230/3/60 – Three Phase – Medium Heat
3 YHC033A3RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – Medium Heat
3 YHC033A4RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – Medium Heat
3 YHC033AWRMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWRMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWRMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
YHC –208-230/3/60 – Three Phase – High Heat
3 YHC033A3RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – High Heat
3 YHC033A4RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – High Heat
3 YHC033AWRHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWRHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWRHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
Factory Supplied
Accessories
A Unit
YCD/H, TCD/H, WCD/H
G Coil Guard (3-7 1/2 Ton)
(BAYGARD)
E Economizer (Downflow and
Horizontal) (BAYECON)
D Fresh Air Damper (BAYDMPR)
Manual (3-25 Ton) (0-25%)
Motorized (5-25 Ton Only) (0-50%)
S Sensor/Thermostat
C Curb (BAYCURB)
Trane offers a variety of factory installed options (FIOPS) for the light commercial packaged rooftop product line. These options
are in addition to the standard factory installed options, i.e., downflow economizer and oversized motors.
Black Epoxy Coated Condenser Coil – Black Epoxy coil protection is a fac- Through the Base Electrical with Disconnect Switch – Factory installed 3-
tory-applied, thermoset vinyl coating that is bonded to the aluminum fin stock pole, molded case disconnect switch with provisions for through the base electri-
prior to the fin stamping process. The pre-coated coils are an economical option cal connections are available. The disconnect switch will be installed in the unit in
for protection in mildly corrosive environments. a water tight enclosure with access through a swinging door. Factory wiring will
be provided from the switch to the unit high voltage terminal block. The switch
Dehumidification Option – The dehumidification (hot gas reheat) option shall will be UL/CSA agency recognized. Note: The disconnect switch
be a factory-installed option that provides increased dehumidification. The will be sized per NEC and UL guidelines but will not be used in place of unit
option shall consist of a hot-gas reheat coil located on the leaving air side of the overcurrent protection.
evaporator coil prepiped and circuited. The option shall be equipped with
crankcase heater(s), low pressure switch(es), Frostat™, and a thermostatic This option is available for all 230, 460 and 575 volt, 3-phase downflow 12½ – 25
expansion valve(s) (TXV) as standard. ton models. Either a Circuit Breaker or a Disconnect Switch (not both) must be
ordered when ordering the Through the Base Electrical option.
Differential Pressure Switches – A dedicated differential pressure switch is
available to achieve active fan failure indication and/or clogged filter indication. Through the Base Gas Piping – With this option, provision will
These indications will be registered on a zone sensor with status indication be made in the unit for installing through the base gas piping. The option will
lights. This option is available for all 12½ – 25 ton models. have all piping necessary including a pre-assembled, black steel, manual gas
shut-off valve, elbows and union. The manual shut-off valve shall include a 1/8
Electric Heaters – Factory installed and wired electric heaters inch NPT pressure tap. This assembly will require minor field labor to install.
are available for all 230, 460, and 575 volt 3-phase horizontal and downflow This option is available for all 12½ – 25 ton downflow gas/electric units, and can
12½ – 25 ton models. If ordering the Through the Base Electrical option with an only be ordered when the Through the Base Electrical Option with Disconnect or
Electric Heater, the heater must be factory installed. Circuit Breaker is ordered.
High Efficiency Motors – Available with efficiency ratings from 86.5 up to 91.0. Thermal Expansion Valve (TXV) and Face Split Evaporator – All units have a
Check unit specifications for specific motor size per unit model. short orifice refrigerant control metering device. For more exact refrigerant flow,
when using units in low airflow or high outside air applications, a Thermal
Hinged Access Doors – Sheet metal hinges are available factory installed on
Expansion Valve option shall be available. This is available on High Efficiency
the Filter/Evaporator Access Door and the Compressor/Control Access Door of
Gas/Cooling units only.
all 12½ – 25 ton downflow units.
Discharge Air Sensing Kit – This option provides true discharge air sensing in
Powered or Unpowered Convenience Outlet – This option is a GFCI, 120
heating models. This sensor is a status indicator readable through Tracer® or
volt/15 amp, 2 plug, convenience outlet, either powered or unpowered. When
Tracker®. The kit is functional only with the ReliaTel™ Module.
the convenience outlet is powered, a service receptacle disconnect will be
available. The convenience outlet is powered from the line side of the Coil Guards – Hail protection quality coil guards shall be either factory or field-
disconnect or circuit breaker, and therefore will not be affected by the position installed for condenser coil protection.
of the disconnect or circuit breaker.
This option is available for all 12½– 25 ton downflow units and can only be High Efficiency Motors – This option is available with efficiency ratings from
ordered when the Through the Base Electrical with either the Disconnect Switch 86.5 up to 91.0. Not available for all models.
or Circuit Breaker option is ordered. Supply and/or Return Air Smoke Detector – With this option installed, if smoke
Reference or Comparative Enthalpy – When a factory installed Downflow is detected, all unit operation will be shut down. Reset will be manual at the unit.
Economizer is ordered, an option will be to factory install either Reference or Return Air Smoke Detectors require minimum allowable airflow when used with
Comparative Enthalpy Control. certain models. See the Installation, Operation, and Maintenance (IOM) manual
for the models affected and the minimum allowable airflow required. This option
Supply and Return Air Smoke Detector – With this option installed, if smoke is available on all 12½-25 tons downflow models.
is detected the line will shut down all operation. Reset will be manual at the unit.
Smoke detectors are photo cell. Frostat – This factory or field installed option is to be utilized as a safety device.
The Frostat opens when temperatures on the evaporator coil fall below 10°F. The
Through the Base Electrical with Circuit Breaker – This option temperature will need to rise to 50°F before closing. This option should be utilized
is a factory installed thermal magnetic, molded case, HACR Circuit Breaker in low airflow or high outside air applications.
with provisions for through the base electrical connections. The circuit breaker
will be installed in a water tight enclosure in the unit with access through a Through the Base Utilities Access – An electrical service entrance shall be
swinging door. Factory wiring will be provided from the switch to the unit high provided allowing electrical access for both control and main power connection
voltage terminal block. The circuit breaker will provide overcurrent protection, inside the curb and through the base of the unit. Option will allow for field
be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. installation of liquid-tight conduit and an external field installed disconnect switch.
This option is available for all 12½ – 25 ton downflow models. Either a Circuit Novar Unit Controls – Novar rooftop unit controls will be factor installed and
Breaker or a Disconnect Switch (not both) must be ordered when ordering the tested. The Novar electronic thermostat module will interface to the unit
Through the Base Electrical option. microprocessor and will control the unit to the desired stage of cooling or heating.
The Novar electronic thermostat module will monitor the following unit
* Some FIOPs available only for certain information: fan failure status, cooling stage 1-on status, cooling stage 2 on
tonnages, unit functions, or efficiencies. status, heating on status, clogged filter status or unit shutdown status, and
discharge air temperature. The Novar electronic thermostat module will have the
ability to enable the unit mounted economizer.
Novar Return Air Sensor – This option, when used in conjunction with Novar
Before Ordering: Controls, will contain a factory provided wired zone temperature sensor located in
the return air stream.
Not all factory options are offered for single phase units.
Please contact the Clarksville, TN Support Team for latest updates of Two Inch Pleated Filters – Two inch pleated media filters shall be available on
all 12½-20 ton models.
factory installed options and ordering instructions.
Call (931) 645-6471 and ask to be connected to the Light Commercial
Product Support Team.
Effective 1/1/06
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
CO* (*=0) Cooling & CO* & CO* &
GE* (* = L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW
T/YFD150D3*0B 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 6125 3200 N/A
T/YFD150D3*BB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 4150 3200 N/A
T/YFD150D4*0B 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4090 N/A
T/YFD150D4*BB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/A
T/YFD150DW*0B 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/A
T/YFD150DW*BB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4060 4080 N/A
T/YFD151C3*0B 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 6125 3200 N/A
T/YFD151C3*BB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4090 4090 N/A 4150 3200 N/A
T/YFD151C4*0B 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4090 N/A
T/YFD151C4*BB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/A
T/YFD151CW*0B 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/A
T/YFD151CW*BB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4060 4080 N/A
T/YFD151C3*HB 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4070 4070 N/A 6125 3200 N/A
T/YFD151C3*JB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 4150 3200 N/A
T/YFD151C4*HB 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4070 4090 N/A
T/YFD151C4*JB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/A
T/YFD151CW*HB 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/A
T/YFD151CW*JB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4060 4080 N/A
T/YFD180B3*0H 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/A
T/YFD180B3*BH 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4100 4100 N/A 4150 3200 N/A
FIOPS-10
T/YFD180B4*0H 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4090 N/A
T/YFD180B4*BH 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/A
T/YFD180BW*0H 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/A
T/YFD180BW*BH 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/A
T/YFD181C3*0C 003 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/A
T/YFD181C3*BC 006 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4100 4100 N/A 4150 3200 N/A
T/YFD181C4*0C 004 213/211 214 214 214 214 N/A 6100 6100 6100 6100 6100 N/A 4050 4050 4050 4070 4090 N/A
T/YFD181C4*BC 007 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/A
T/YFD181CW*0C 005 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/A
T/YFD181CW*BC 008 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/A
T/YFD181C3*HC 003 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/A
T/YFD181C3*JC 006 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4090 N/A 4150 3200 N/A
T/YFD181C4*HC 004 213/211 214 214 214 214 N/A 6100 6100 6100 6100 6100 N/A 4050 4050 4050 4070 4090 N/A
T/YFD181C4*JC 007 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/A
T/YFD181CW*HC 005 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/A
T/YFD181CW*JC 008 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/A
FACTORY INSTALLED OPTIONS (FIOPS)
(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. T/YCD). ALL FACTORY INSTALLED
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat.
OPTIONS ARE BUILT-TO-ORDER.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for CHECK ORDER SERVICES FOR
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th ESTIMATED PRODUCTION CYCLE.
digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th
digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections.
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
CO* = Cooling Only GE* = Gas Electric
Downflow Packaged Cooling, & Gas Electric
Factory Installed Options (FIOPS)
Matrix Page (Contd.)
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
CO* (*=0) Cooling & CO* &
GE* = (*= L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW CO*/GE* 18KW 27KW 36KW 54KW 72KW
T/YFD210C3*0E 006 207/206 N/A N/A 209 210 N/A 6100 N/A N/A 4150 3250 N/A 4100/4100 N/A N/A 4150 3200 N/A
T/YFD210C3*BE 009 207/206 N/A N/A 209 210 N/A 4150 N/A N/A 4150 3250 N/A 6125/4125 N/A N/A 4150 3200 N/A
T/YFD210C4*0E 007 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4050/4050 N/A N/A 4070 4100 N/A
T/YFD210C4*BE 010 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4060/4060 N/A N/A 4070 4100 N/A
T/YFD210CW*0E 008 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4045/4045 N/A N/A 4060 4080 N/A
T/YFD210CW*BE 011 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4045/4045 N/A N/A 4060 4080 N/A
T/YFD211C3*0C 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6110/4110 N/A N/A 4150 3200 3250
T/YFD211C3*BC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD211C4*0C 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125
T/YFD211C4*BC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
T/YFD211CW*0C 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4045/4045 N/A N/A 4060 4080 4100
T/YFD211CW*BC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD240B3*0J 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD240B3*BJ 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD240B4*0J 007 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
T/YFD240B4*BJ 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
FIOPS-11
T/YFD240BW*0J 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4045/4045 N/A N/A 4060 4080 4100
T/YFD240BW*BJ 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD241C3*0C 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C3*BC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C4*0C 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125
T/YFD241C4*BC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
T/YFD241CW*0C 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
TFD241CW*BC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD241C3*HC 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C3*JC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C4*HC 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125
T/YFD241C4*JC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4070/4070 N/A N/A 4070 4100 6125
T/YFD241CW*HC 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD241CW*JC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
Effective 1/1/06
Downflow Packaged Cooling, & Gas Electric
Factory Installed Options (FIOPS)
Effective 1/1/06
Matrix Page (Contd.)
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
CO* (* = 0) Cooling & CO* & CO* &
GE* = (L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW
T/YFD300B3*0H 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 4150 N/A N/A 4150 3200 3250
T/YFD300B4*0H 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4070 N/A N/A 4070 4100 6125
T/YFD300BW*0H 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050 N/A N/A 4060 4080 4100
T/YFD301C3*0C 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 4150 N/A N/A 4150 3200 3250
T/YFD301C4*0C 010 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4070 N/A 4070 4070 4100 6125
T/YFD301CW*0C 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4060 N/A N/A 4060 4080 4100
FIOPS-12
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
CO* = Cooling Only
GE* = Gas Electric
FIOPS-13
WFD150B400G 004 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4040 4060 4090 6125 N/A
WFD150B40BG 007 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4040 4070 4090 6125 N/A
WFD150BW00G 005 207 208 208 208 N/A 6100 6100 6100 6100 N/A 4030 4050 4070 4090 N/A
WFD150BW0BG 008 207 208 208 208 N/A 6100 6100 6100 6100 N/A 4035 4050 4080 4100 N/A
FACTORY INSTALLED OPTIONS (FIOPS)
(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. WCD).
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th
digit for FIOP selections.
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
* Cooling Only
Effective 1/1/06
Downflow Packaged Heat Pump
Effective 1/1/06
Factory Installed Options (FIOPS)
Matrix Page (Contd.)
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
without without without
aux. heat aux. heat aux. heat
CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW
WFD180B300G 003 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4090 4150 3200 3250 N/A
WFD180B30BG 006 207 209 210 NA N/A 6100 4150 3250 3250 N/A 4100 4150 3200 3250 N/A
WFD180B400G 004 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4045 4070 4100 6125 N/A
WFD180B40BG 007 207 208 209 209 N/A 6100 6100 6100 4150 N/A 4050 4070 4100 6125 N/A
WFD180BW00G 005 207 208 208 209 N/A 6100 6100 6100 6100 N/A 4035 4060 4080 4100 N/A
WFD180BW0BG 008 207 208 208 209 N/A 6100 6100 6100 6100 N/A 4040 4060 4080 4100 N/A
WFD240B300G 006 213 N/A 216 216 N/A 4150 N/A 3250 NA N/A 6125 N/A 3225 NA N/A
WFD240B30BG 009 213 N/A 216 NA N/A 4150 N/A 3250 NA N/A 6125 N/A 3225 NA N/A
WFD240B400G 007 213 N/A 215 215 N/A 6100 N/A 4150 4150 N/A 4060 N/A 6110 4150 N/A
FIOPS-14
WFD240B40BG 010 213 N/A 215 215 N/A 6100 N/A 4150 4150 N/A 4060 N/A 6110 4150 N/A
WFD240BW00G 008 213 N/A 214 215 215 6100 N/A 6100 4150 4150 4045 N/A 4090 6110 6125
WFD240BW0BG 011 213 N/A 214 215 215 6100 N/A 6100 4150 4150 4050 N/A 4090 6110 4150
TCONT800A Application:
• Interactive Touchscreen • 1 Heat/1 Cool (Gas, Oil or Electric)
• Effortless Programming • 1 Heat/0 Cool (Gas, Oil or Electric)
• Large, Backlit Display • 0 Heat/1 Cool
• Streamlined Design • ZZSENSAL0800AA - Remote Indoor
• Armchair Programming Temperature Sensor
• Real Time Clock Dimensions:
• Visual Reminder Cues • 6.02” w x 4.62” h
• BAYCOVR600A - Wall cover plate • Finish: Bright White
• Energy Star
TCONT802A Application:
• Interactive Touchscreen • Up to 3 Heat/2 Cool
• Effortless Programming (Gas, Oil or Electric)/HP
• Large, Backlit Display • ZZSENSAL0800AA - Remote Indoor
• Streamlined Design Temperature Sensor
• Armchair Programming Dimensions:
• Real Time Clock • 6.02” w x 4.62” h
• Visual Reminder Cues • Finish: Bright White
• BAYCOVR600A - Wall cover plate
• Energy Star
TCONT803A Application:
• Built-in Humidity Sensor • Up to 3 Heat/2 Cool
• Dehumidification Control (Gas, Oil or Electric)/HP
• Interactive Touchscreen • ZZSENSAL0800AA - Remote Indoor
• Effortless Programming Temperature Sensor
• Large, Backlit Display Dimensions:
• Streamlined Design • 6.02” w x 4.62” h
• Armchair Programming • Finish: Bright White
• Real Time Clock
• Visual Reminder Cues
• BAYCOVR600A - Wall cover plate
• Energy Star
BAYCOVR600A
Application: • Finish: Bright White
• Use with TCONT800A Series Comfort
Controls
ed
• Outdoor Temperature Display (Optional • Minimum Compressor Run Time
Accessory – TAYSENS100A) (Factory Set to 10 Minutes, Field
s
a t • Bright Backlight Display Adjustable)
P u
PHASED
systems with electric heat Vacation/Leave Temperature for up to
• Filter Clean/Replacement Key (Field 256 Days
O Adjustable)
• No Batteries Required; Super Cap
• Field Temperature Re-Calibration Offset
(Field Adjustable); Allows Installer to Set
Continues Clock for an Average of Thermostat to Customer’s Wall-Mounted
30 Minutes Thermostat Setting
TAYSTAT300C • Programming and Other Functions • Fan-On Heat with Terminal (Heat/Cool
Stored in Permanent “E-PROM” Memory Models, Field Adjustable); i.e. Fan “G”
XT300C
OUT
• Conventional or Adaptive Intelligent is Activated with “W” (Electric Heat
• Single Stage Heating/Cooling Recovery (Field Selectable) Installations)
• 7 Day, 24 Hour or Constant • Daylight Savings Time Key • “Comfort "R"™” Enhanced Cooling for
Temperature Programming • Gas only models do not need resistor PSC Motors, Field Activated (This is
• 4 Temperature Set Points Per Day • Programmable Fan – Fan can be Only a Portion of Comfort "R"™ that is
• Power Stealing 4-wire Programmed in the “ON” or “AUTO” Achieved with Variable Speed Equip-
• Manual or Auto Changeover (Field Mode for Each Period ment)
Selectable) • Finish: Bright White
ed
• Bright Backlight Display • Vacation/Leave Program; Will Hold
• Filter Clean/Replacement Key (Field Ad- Vacation/Leave Temperature for up to
s
a t
justable) 256 Days
h
PHASED
• No Batteries Required; Super Cap • Field Temperature Re-Calibration Offset
OUT
• 2 Heat/2 Cool Recovery (Field Selectable) • “Comfort "R"™” Enhanced Cooling for
• 7 Day, 24 Hour or Constant • Daylight Savings Time Key PSC Motors, Field Activated (This is
Temperature Programming • Programmable Fan – Fan can be Only a Portion of Comfort "R"™ that is
• 4 Temperature Set Points Per Day Programmed in the “ON” or “AUTO” Achieved with Variable Speed Equip-
• Manual or Auto Changeover (Field Mode for Each Period ment)
Selectable) • Minimum Compressor Run Time • Finish: Bright White
• Outdoor Temperature Display (Optional (Factory Set to 10 Minutes, Field
Accessory – TAYSENS100A) Adjustable)
ed
as t
PHASED
• Filter Clean/Replacement Key (Field • Minimum Compressor Run Time (Factory
Adjustable) Set to 10 Minutes, Field Adjustable)
h
P u • No Batteries Required; Super Cap
Continues Clock for an Average of
• Vacation/Leave Program; Will Hold
Vacation/Leave Temperature for up to
O 30 Minutes
• Field Select 1 or 2 Stage
256 Days
• Field Temperature Re-Calibration Offset
TAYSTAT500C • Programming and Other Functions (Field Adjustable); Allows Installer to Set
XT500C Stored in Permanent “E-PROM” Memory Thermostat to Customer’s Wall-Mounted
OUT
• Conventional or Adaptive Intelligent Thermostat Setting
• 2 Heat/1 Cool
• 3 Heat/2 Cool Heat Pumps Recovery (Field Selectable) • Fan-On Heat with Terminal (Heat/Cool
• 7 Day, 24 Hour or Constant • Factory shipped 2 Heat/1 Cool Models, Field Adjustable); i.e. Fan “G” is
Temperature Programming Activated with “W” (Electric Heat
• If needed, Installation setup allows Installations)
• 4 Temperature Set Points Per Day control to be used in 3 Heat/1 Cool
• Manual or Auto Changeover (FieldSe- • “Comfort "R"™” Enhanced Cooling for
lectable) • Daylight Savings Time Key PSC Motors, Field Activated (This is Only
• Outdoor Temperature Display • Programmable Fan – Fan can be a Portion of Comfort "R"™ that is
(Optional Accessory – TAYSENS100A) Programmed in the “ON” or “AUTO” Achieved with Variable Speed Equipment)
• Bright Backlight Display Mode for Each Period • Finish: Bright White
BAYCOVR700A
• 1 Heat (Gas/Electric)/1 Cool • Programming Stored In Permanent
d
Phase
• Heat/Off/Cool System Switch “E-PROM” Memory
• Power Stealing 4 Wire • No Batteries
Out
TAYSTAT340
•
•
•
•
PHASED OUT
5/2 Programmable
Auto/On Fan Switch
Manual Changeover
Super Cap Continues Clock for an
Average of 30 Minutes
• Fuel Selection Switch (Gas/Electric)
• Adjustable Heating Cycle Rate
• Finish: Bright White
d
Phase
• 2 Heat (Gas)/1 Cool • Programming Stored In Permanent
• Heat/Off/Cool System Switch “E-PROM” Memory
• 5/2 Programmable • No Batteries
Out
TAYSTAT350
•
•
•
PHASED OUT
Auto/On Fan Switch
Manual Changeover
Super Cap Continues Clock for an
Average of 30 Minutes
• Adjustable Heating Cycle Rate
• 6-wire connection
• Finish: Bright White
d
Phase
• 2 Heat/1 Cool • Programming Stored In Permanent
• Heat/Off/Cool/Emergency Heat “E-PROM” Memory
System Switch • No Batteries
Out
Heat Pump
TAYSTAT540
PHASED OUT
• 5/2 Programmable
• Auto/On Fan Switch
• Manual Changeover
• Super Cap Continues Clock for an
• Adjustable Heating Cycle Rate
• Finish: Bright White
Average of 30 Minutes
TCONT402A Dimensions:
• Auto Changeover 6.75" w x 4.52" h
• Backlit Display & Keys • Finish: Bright White
• Comfort Information Compartment * Requires external relay for oil furnace
• Energy Savings Mode applications.
• Filter Reminder * Installation is required for outdoor
• BAYSEN01ATEMPAA-Outdoor temperature sensing and display
Temperature Sensor included* * BAYSEN01ATEMPAA required for
• Keypad Lock outdoor temperature sensing and
Application (3-9 Wire Hookup -2 display
for Outdoor Sensor) Heat Pump*
or A/C
• 3 Heat/2 Cool
• No external Dual Fuel Kit Required
• ZZSENSAL0400AA - Remote Indoor
Temperature Sensor
TCONT200A Dimensions:
• Auto Changeover • 4.25" (W) x 5.33" (H)
• Back Lit Display & Keys Application (4 wire hookup - power
• Comfort Information Compartment stealing)*
• Energy Savings Mode • 1 Heat/1 Cool (Gas, Oil or electric)
• Filter Reminder • 1 Heat/0 Cool (Gas, Oil or electric)
• Key Pad Lock • 0 Heat/1 Cool
• Finish: Bright White
TAYSTAT380 • No Batteries
Pha
Out
•
•
•
•
PHASED OUT
Heat/Off/Cool System Switch
Auto/On Fan Switch
Manual Changeover
Digital Display
Retention
• Adjustable Heating Cycle Rate
• Finish: Bright White
d TAYSTAT570 • No Batteries
Phase
PHASED OUT
• 2 Heat /1 Cool • Permanent Temperature Setting
• Heat/Off/Cool/Emergency Heat Retention
d TAYSTAT575 • No Batteries
Phase
Heat
PHASED OUT
• 3 Heat /2 Cool (Field Selectable) • Manual or Auto Changeover
• Factory Ships 2 Heat/1 Cool • Permanent Temperature Setting
PHASED OUT
Heat
Retention
Out
•
•
•
•
PHASED OUT
Power Stealing 4 Wire
Heat/Off/Cool System Switch
Auto/On Fan Switch
Manual Changeover
• Permanent Temperature Setting
Retention
• Adjustable Heating Cycle Rate
• Finish: Bright White
Out
with control)
• Heat/Off/Cool System Switch • Finish: Bright White
• Auto/On Fan Switch
BAYSEN02ATEMPAA
• Outdoor Temperature Sensor for Use
with TCONT800, 802, 803
• Accuracy +/– 1°F from –40 to 120°F
as PHASED OUT
• Outdoor Temperature Sensor for Use
Ph ut
with TAYSTAT300C, 302C, 500C, 575
and 375
• Accuracy +/– 1°F from –40 to 120°F
O
BAYSEN01ATEMPAA
• Outdoor Temperature Sensor for Use
with TCONT401A & 402A
• Accuracy
+/- 15°F over 32°F to 100°F
• Display Range
-40°F to 140°F
ZZSENSAL0400AA
• Indoor Sensor for Use with Dimensions in in. (mm):
TCONT402 Comfort Controls • 1.54 (39) wide x 1.93 (49) high x .625
• Operating Ambient Temperature (1.6) deep
Range: 20° to 120°F (-6.7° to 48.9°C) • Storage Temperature: -40° to 140°F
• Display Range: 20° to 120°F (-40° to 60°C)
(-6.7° to 48.9°C) • Finish: White
• Sensor Accuracy: +/-.5°F at 75°F
• Operating Relative Humidity: 5% to
90% non-condensing
ZZSENSAL0800AA
• Indoor Temperature Sensor for Use Dimensions in in. (mm):
with TCONT800, 802, 803 • 1.50 (38) wide x 2.28 (58) high x .70
• Operating Ambient Temperature (18) deep
Range: 45 to 88°F (7.2 to 32°C) • Finish: White
• Display Range: 0 to 99°F (-18 to 37°C)
• Sensor Accuracy: +/-1.5°F at 70°F
(+/-.84 at 21°C)
• Operating Relative Humidity: 5% to
95% non-condensing
Relay Hook-Up
BAY24X045
• For application to furnaces and air
handlers with cooling coils equipped
with capillary tube or 15% bleed
expansion valve components.
• This kit allows the indoor fan to
continue to run a short time after the
outdoor unit shuts off for increased
cooling efficiency.
• The kit contains: 1 solid state time
delay relay with four (4) color coded
wires, 1 wiring diagram, 1 notice label,
1 mounting screw.
Cooling Only
BAY28X186
• 0 Heat/2 Cool
• Can be Used for Economizer Operation
• Use with BAY28X187 Subbase only
• Off/Auto System Switch
Subbase is required
• Auto/On Fan Switch
(shown with 187 subbase)
• Clear Plastic Set Point Lever
• Thermometer can be Calibrated
• Finish: Beige and Gold
Cooling Only
BAYSTAT304
• 0 Heat/1 Cool
• Off/Auto/Fan System Switch
• Clear Plastic Set Point Lever
• Finish: Bright White
Heating Only
BAYSTAT303
• 1 Heat/0 Cool
• Gas Heat Compatible
• Off/Auto/Fan System Switch
• Clear Plastic Set Point Lever
• Not Electric Heat Compatible
• Requires BAY24X042 Relay for
Indoor Fan Operation when used
for Electric Heat
• Adjustable Heat Anticipator
• Finish: Bright White
Remote Sensor
BAYSENS033A
• Remote Sensor for use with • Vendor: Honeywell
BAYSTAT040B • Finish: Bright White
• Allows convenient thermostat location
and optimum temperature sensing
location
• Maximum distance from thermostat
to sensor = 1000 ft.
• Use 3 conductor (18-26 AWG)
shielded, and insulated cable
BAYSENS034A
• Return Air Remote Temperature
Sensor for use with BAYSTAT040B
Note: XL16i models, both cooling or heat pump models, are not approved for Trane Comfort Link™ Zoning System.
Outdoor Temperature Sensor: Outdoor temperature only sensor. Can be used with ZUSTATALS51, ZUSTATALP51, or
ZUSTATALMS1. Weather proofed.
Installation: 18-HD60D41
Source: Clarksville
High Efficiency Centrifugal Fan Gas • Factory Installed Flue Vent Fan
Unit Heater • Combustion Air Pressure Switch
• Horizontal Louvers • “10 Year Non-Prorated Warranty”
• 115/60/1 Open Drip-proof Motor with on the Heat Exchanger, Burners
Built-in T.O.P. and Draft Hood Assembly.
• Fan Guard
• 24V Control Transformer
• Junction Box for Power Wiring
• Single-Stage Intermittent Pilot Ignition
• Fan Time Delay Relay
• Aluminized Steel Heat Exchanger
High Efficiency Indoor Gas Duct Note: A drain pan is not included.
Furnace See field installed options.
• Blow Through Applications Only
• 24V Control Transformer
• Junction Box For Power Wiring
• Single-Stage Combination Gas Valve
• Intermittent Pilot Ignition
• Aluminized Steel Heat Exchanger
• Factory Installed Flue Vent Fan
• Combustion Air Pressure Switch
• 10 year warranty “does not apply.”
Trane’s standard 12/18 month only.
Table PTAC/UH-8-C — Tubular Heat Exchanger - Residential Propeller Fan Gas Unit Heater
Unit Size R03 R04 R06 R07 R09
MBh (input) 30 45 60 75 90
MBh (output) 24.3 36.5 48.6 60.8 72.9
Tubular - Residential Alum
GTND or GTPD
Std. 115/60/1 motor hp 1/20 1/20 1/20 1/20 1/20
Notes:
1. Includes standard 115/60/1 open drip-proof (ODP) motor. If totally enclosed 115/60/1 motors are required.
2. Units only available with Aluminized Heat Exchanger, stainless steel not available or required.
3. Factory installed flue vent fan is included.
4. The only gas control option available is single stage, hot surface pilot ignition. This is included in the unit.
5. Includes spil or flame roll out switch.
6. Includes OSHA Fan Guard.
6” Ordering No
Vent Cap 0350-0158- — — — — — — — — — — — 01 01 01
5” to 4” Ordering No
Reducer 0350-0156- 01 01 01 01 01 01 01 01 — — — — — —
5 to 6” Ordering No
Increaser 0350-0159- — — — — — — — — — — — 01 01 01
Notes:
1. These are mandatory, for the Canadian market, per the National Standard of Canada section B149, 1M91 for category 3 venting: (III). Use Certified venting system provided
by (Manufacturer).
2. Tubular heat exchanger units do not require reducers or increasers.
Table PTAC/UH-14-D— Vertical Louver Kits (Propeller and Centrifugal Fan Unit Heaters Only)
GPND
030 004 006 007 010 012 015 017 020 022 025 030 035 040
Ordering No. Contact Macon Product Support
Quantity Required for Ordering Information
Notes:
1. Kits are for use in modifying existing units in the field. Kits for GPND-003 thru 007 are complete assemblies including frame and louvers. Kits for all other units include
individual louver with fastening springs.
2. When ordering vertical louvers for new equipment, refer to Table PTAC/UH-11-A.
3. These Kits are not available for Tubular Heat Exchanger units.
Table PTAC/UH-17-A—All Indoor Duct Furnaces (Std., High Effic. and Separated Combustion Units) Heat Exchanger Warranty Net
Prices Option Extended Warranty1
5 year 10 year
Unit MBh 2nd-5th year 2nd-10th year
Size input alum 409SS 321SS alum 409SS 321SS
010 100
012 125
015 150
017 175
020 200
022 225
025 250
030 300
035 350
040 400
Ordering Number 2705-4000-05-00 2705-4000-06-00
Product Code 588 588
Note:
1. The extension applies only to new equipment installed in domestic sales territories and must be ordered prior to start-up.
1. Model S Unit Heaters (Tables PTAC/UH- 3. Coils Unit heater name plates will use the 11th digit
19-A-PTAC/UH-25-E) include stock units, The standard coil is 1-row 0.031'’ wall 1'’ of the 21 digit model number system to
as well as production unit casing with O.D. copper tubing with 108 Sigma-Flo® designate the coil tube material as follows —
motor, coil, fan, fin, tube, fan guard and aluminum fins per foot and are suitable for A — STD. COPPER
horizontal louvers. service on steam to 75 psi and water at
325° at 200 psi. Coil variations are as C — RED BRASS
2. Units with modified coils (odd numbered
units) are generally not suitable for entering indicated in F — STEEL
water temperatures below 180° because of PTAC/UH-18-A.
4. Motors
low final air temperatures. See Engineering Standard cycle motors are indicated in
Bulletin EB-UH7 (photocopy only available PTAC/UH-18-B.
from Inland printing 608-783-4700 or on
EAGLE), 15-24 for capacity data.
1. Model P Unit Heaters (Tables PTAC/UH- 4. Unit heater name plates will use the 11th
27-A-PTAC/UH-30-A) include stock units, digit of the 21 digit model number system
as well as production unit casing with to designate the coil tube material as
motor, coil, fin, tube, fan guard and fan. follows:
A — STD. COPPER
2. Model PL Unit Heaters are identical to
Model P. The performance difference is a C — RED BRASS
F — STEEL
result of removing the air ports in the field.
3. Coils 5. Motors
Standard cycle motors are described in
The standard coil 1-row 0.025'’ wall 5/8'’
O.D. copper with 144 Sigma-Flo® aluminum Table PTAC/UH-26-B.
fins per foot and threaded steel pipe Special motors may be ordered.
(575/60/3) by putting appropriate
headers. Coils are suitable for service on
75 psi steam or water at 325 F at 225 psi. designators in Digits 13 and 14 of model
Coil variations are as indicated in Table number. Contact St. Louis (888-872-6302)
PTAC/UH-26-A.
Table PTAC/UH-26-A—Type ‘’P’’ Unit Heater Coil — Temperature & Pressure Limitations
Tube Steam Hot Water
Model P Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin Material
Copper (Std.) 5/8'’ .025'’ 75 325 225 325
Red Brass 5/8'’ .049'’ 75 325 300 425 Alum. or Copper
Steel 5/8'’ .049'’ 75 325 400 450 (Std.)
Table PTAC/UH-30-B— Packed Stock Model S Unit Heater Order Numbers & Equivalent Production Model Numbers
Horizontal Model S Unit Heaters Constant Speed
Stock Order Production Order
Size Order No. Type Model No. Type Notes
18S 136-0101-01 STK UHSA018S8EAA1T0000000 PRD 1
20S2* 136-0102-01 STK UHSA020S2EAA1T0000000 PRD 1
38S 136-0103-01 STK UHSA038S8EAA1T0000000 PRD 1
42S 136-0104-01 STK UHSA042S8EAA1T0000000 PRD 1
60S 136-0105-01 STK UHSA060S8EAA1T0000000 PRD 1
70S 136-0106-01 STK UHSA070S8EAA1T0000000 PRD 1
90S 136-0107-01 STK UHSA090S8EAA1T0000000 PRD 1
100S 136-0108-01 STK UHSA100S8EAA1T0000000 PRD 1
126S 136-0109-01 STK UHSA126S8EAA1T0000000 PRD 1
168S 136-0110-01 STK UHSA168S8EAA1T0000000 PRD 1
186S 136-0111-01 STK UHSA186S8EAA1T0000000 PRD 1
230S 136-0112-01 STK UHSA230S8EAA1T0000000 PRD 1
260S 136-0113-01 STK UHSA260S8EAA1T0000000 PRD 1
320S 136-0114-01 STK UHSA320S8EAA1T0000000 PRD 1
354S 136-0115-01 STK UHSA354S8EAA1T0000000 PRD 1
Notes:
1. For steam or hot water coils made from .031 copper tubes. Aluminum fins (*108 per foot) and steel pipe headers. Fans made with steel hubs and aluminum blades. Sleeve
bearing motors are 115/60/1. TEAOM with TOP and class B insulation. Type No. 1 motor mount (wire guard) furnished. Variable speed motors furnished on sizes 18S thru 100S
as standard. Requires a solid-state speed control which must be ordered separately. Unit casings top, front, back and sides made from steel with adjustable louvers
phosphatized and painted with a blue-gray baked enamel finish.
*Size 20S2 stock unit furnished with 132 fins per foot as standard.
Table PTAC/UH-30-C— Packed Stock Model P Unit Heater Order Numbers & Equivalent Production Model Numbers
Vertical Model P Unit Heaters Constant Speed
Stock Order Production Order
Size Order No. Type Model No. Type Notes
42P 136-0143-01 STK UHPA042P4CAA1T0000000 PRD 1
64P 136-0144-01 STK UHPA064P4CAA1T0000000 PRD 1
80P 136-0145-01 STK UHPA080P4CAA1T0000000 PRD 1
102P 136-0146-01 STK UHPA102P4CAA1T0000000 PRD 1
122P 136-0147-01 STK UHPA122P4CAA1T0000000 PRD 1
146P 136-0148-01 STK UHPA146P4CAA1T0000000 PRD 1
166S 136-0149-01 STK UHPA166P4CAA1T0000000 PRD 1
202P 136-0150-01 STK UHPA202P4CAA1T0000000 PRD 1
252P 136-0151-01 STK UHPA252P4CAA1T0000000 PRD 1
280P 136-0152-01 STK UHPA280P4CAA1T0000000 PRD 1
336P* 136-0153-01 STK UHPA336P4CAA1T0000000 PRD 1
Notes:
1. For steam or hot water coils made from .025 copper tubes. Aluminum fins (144 per foot) and steel pipe headers. Fans made with steel hubs and aluminum blades. Sleeve
bearing motors are provided for 1/20 & 1/8 HP ranges and ball bearing motors provided for 1/6, 1/4, & 1/2 HP ranges are 115/60/1. TE with TOP and class B insulation. Steel
motor mount furnished. Variable speed motors furnished on sizes 42P thru 102P as standard. Requires a solid-state speed control which must be ordered separately. Casings
made from two steel plates with the top plate having air ports as standard, phosphatized and painted with a blue-gray baked enamel finish.
*Size 336P stock unit uses a 230/460/60/3, ball bearing, TE with class B insulation motor as standard.
Table PTAC/UH-35-A—Accessories
Model No. Order No. Description wt. lbs.
Wall/Ceiling Mounting Bracket (horiz. discharge)
A5105 236-723 2-5 kW Bracket 6.0
A5120 236-724 7-20 kW Bracket 9.0
A5150 236-725 25-50 kW Bracket 11.0
Dust Shield (horiz. discharge)
DS5105 233-740 3.3-5 kW Dust Shield .5
DS5120 233-741 7.5-20 kW Dust Shield .5
DS5150 233-742 25-50 kW Dust Shield .5
Ceiling Mtg. Bracket (vert. discharge)
V5105 236-726 2-5 kW Bracket 9.0
V5120 236-727 7-20 kW Bracket 13.0
V5150 236-728 25-50 kW Bracket 13.0
Louver Cone Diffusers (vert. discharge only)
RD5120 236-920 7-20 kW Diffuser 8.0
RD5150 236-922 25-50 kW Diffuser 12.0
Anemostat Diffusers (vert. discharge only)
AD5120 233-730 7-20 kW ANEMOSTAT 9.0
AD5150 233-731 25-50 kW ANEMOSTAT 13.0
Table PTAC/UH-42-B—Electric Wall Mounted Unit Heaters without Unit Mounted Thermostat
Order Element
kW No. + Motor Element Ship Amp
Rating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating
021A2A0 n/a 208 1 9.6 9.6
2000W 021B2A0 n/a 240 1 8.3 41 8.3
021C2A0 n/a 277 1 7.2 7.2
031A2A0 n/a 208 1 14.4 14.4
3000W 031B2A0 n/a 240 1 12.5 41 12.5
031C2A0 n/a 277 1 10.8 10.8
041A2A0 n/a 208 1 19.2 19.2
041B2A0 n/a 240 1 16.7 16.7
4000W 041C2A0 n/a 277 1 14.4 41 14.4
043A2A0 n/a 208 3 11.1 11.1
043B2A0 n/a 240 3 9.6 9.6
051A2A0 n/a 208 1 24.0 24.1
051B2A0 n/a 240 1 20.8 20.8
5000W 051C2A0 n/a 277 1 18.0 41 18.1
053A2A0 n/a 208 3 13.9 13.9
053B2A0 n/a 240 3 12.0 12.1
All Sizes 3420 233-440 Wall Box5 9
1. Only contactor can be built-in on Series 20 Wall Heaters.
2. Wall box must be ordered.
Table PTAC/UH-43-B— Electric Wall Mounted Unit Heaters without Unit Mounted Thermostat
Order Element
kW No. + Motor Element Ship Amp
Rating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating
021A5A0 n/a 208 1 9.6 9.6
2000W 021B5A0 n/a 240 1 8.3 54 8.3
021C5A0 n/a 277 1 7.2 7.2
031A5A0 n/a 208 1 14.4 14.4
3000W 031B5A0 n/a 240 1 12.5 55 12.5
031C5A0 n/a 277 1 10.8 10.8
041A5A0 n/a 208 1 19.2 19.2
041B5A0 n/a 240 1 16.7 16.7
4000W 041C5A0 n/a 277 1 14.4 55 14.4
043A5A0 n/a 208 3 11.1 11.1
043B5A0 n/a 240 3 9.6 9.6
051A5A0 n/a 208 1 24.0 24.1
051B5A0 n/a 240 1 20.8 20.8
5000W 051C5A0 n/a 277 1 18.0 55 18.1
053A5A0 n/a 208 3 13.9 13.9
053B5A0 n/a 240 3 12.0 12.1
All Sizes 3450 233-450 Wall Box5 11
1. If circuit breaker and/or transformers are required, the Series 50 wall heater must be ordered.
2. Wall box must be ordered.
1
/4” Wire Mesh
1. Factory installed under grille on enclosure or Blank Enclosure Sections and Extended Enclosure Sections with open
grilles.
IF APPLICABLE
PROMO STAMP
Dealer/Seller Servicer (if other than Dealer/Seller)
through the first (1st) year. Labor Option EQUIPMENT OWNER: (Mailing Address) EQUIPMENT LOCATION: (If Different)
#2 is not available on equipment over 9
Name Name
months old or on "Parts Only" Optional Address Address
Extended Warranties. City State Zip (Required) City State Zip (Required)
ninety-first (91st) day from the date of ___________________ _________________________ __________________________ Date Warranty Sold ___________________
By Dealer
installation or the date activated, ___________________ _________________________ __________________________
whichever is later. The dealer is respon- ___________________ _________________________ __________________________ Warranty Sales Price $ __________________
sible for labor through the first ninety If the Equipment Covered is a Compressor Only – What is the Condensing Unit Model # ___________________________________
(90) days. What is the Condensing Unit Serial # ___________________________________
Coverage for Labor Option #3 will cost This Document is an Application Only. The Extended Warranty will become effective when accepted by
The Trane Company. The Trane Company will notify the Equipment Owner by sending the Extended Warranty
more than the other two options. If it Agreement that provides coverage for the Extended Warranty Model listed above. If you do not receive a
confirming agreement from Trane within 45 days, please call 800-554-6413.
is chosen, the Trane Optional Extended
As the Equipment Owner, I acknowledge that I have
Warranty Agreement will automatically read and understand the “Terms and Conditions” as well
Dealer/Seller’s Signature* Date as the type of coverage and length of coverage of the
be assigned the letter “X” to the end of Trane Extended Warranty for which I have applied.
the model number. (Example: DEALER INSTRUCTIONS: Send To Your Distributor For Processing.
Equipment Owner’s Signature Date
TAYWAR0004 that contains Labor * Dealer/Seller’s signature indicates equipment over 9 months old has been inspected and is in good working condition.
Option #3 will become TAYWAR0004X). Inspection not required if equipment is less than 9 months old or if this is a renewal of an existing extended warranty.
Pub. No. 26-1021-06 (12/00)
To determine the exact cost of an Trane or latest version
Optional Extended Warranty that
contains Labor Option #3, refer to the
price book and select the model number
that contains the letter “X” Labor options are chosen at the time an application is completed using the three
at the end of the model number. It is not (3) selection blocks on the application form (see above). The dealer simply marks
necessary to indicate the the option chosen. When the application is activated, that agreement will always be
“X” in the model number when associated with that Labor Option. If no option is chosen, then option #1 will
completing an application. automatically be selected.
The “Servicer Guideline Rates” for Refer to the Trane Optional Extended Warranty Handbook for additional information
labor options #1, #2, and #3 are (Pub. No. 26-1019).
used when submitted claims and
are noted on page WA-2 and WA-3.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty
section of the Residential and Light Commercial Products Handbook; however, the information in
the Trane Optional Extended Warranty handbook supersedes all information contained herein.
3. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is less
than the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, each
additional component may receive a maximum of 0.5 hours. For any component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time is
greater than the amounts specified below, or as described in this paragraph, and you believe that additional time is justified, please explain the circumstances of the repair or
replacement in writing.
Max Hours Allowed
Replacement or Repaired Item 1-5 Tons 6 1/4 - 25 Tons
Refrigerant Circuit2
Refrigerant recovery (only if required) ........................................................................... 1.0 2.0
Compressor replacement3 ........................................................................................... 4.0 6.0
Condenser coil replacement .......................................................................................... 4.0 6.0
Evaporator coil replacement .......................................................................................... 4.5 6.0
Expansion valve replacement ........................................................................................ 3.0 4.0
Switch over valve replacement ...................................................................................... 3.5 4.5
Check valve replacement or service valve ..................................................................... 2.0 3.0
Drier replacement .......................................................................................................... 1.0 1.0
Schrader core ................................................................................................................ 0.5 0.5
Tighten valves (caps, cores, rotolocks) .......................................................................... 0.5 0.5
Repairable leak in fitting, etc. (brazing required explain work done) ............................. 2.0 3.0
Electrical Controls
Any component replacement ......................................................................................... 0.5 0.5
Hard start kit ................................................................................................................... 0.5 —
Thermostat (Indoor) ....................................................................................................... 1.0 1.0
Thermostat (Outdoor) .................................................................................................... 0.5 0.5
Crankcase heater replacement ...................................................................................... 0.5 0.5
Condenser Fan Assemblies
Fan blade replacement .................................................................................................. 0.5 0.5
Motor replacement (includes fan blade capacitor) ......................................................... 1.5 1.5
Evaporator Fan Assembly
Blower wheel replacement ............................................................................................. 1.0 1.0
Motor replacement (includes blower wheel, capacitor) .................................................. 1.5 1.5
Module replacement (includes motor) ............................................................................ 1.0 1.0
Bearing replacement - each ........................................................................................... 0.5 0.5
Sheaves replacement - each (includes belt) .................................................................. 0.5 0.5
Belt replacement ............................................................................................................ 0.5 0.5
Drain pan replacement ................................................................................................... 2.0 2.0
Heating Section
Any control replacement (ignitor, sensor, ignition control, etc.) .................................... 0.5 0.5
Heating element replacement ........................................................................................ 1.0 1.0
Combustion blower replacement ................................................................................... 1.0 1.0
Gas valve replacement .................................................................................................. 1.0 1.0
Heat exchanger replacement ......................................................................................... 4.0 6.0
Burners .......................................................................................................................... 1.0 1.0
Economizer Section Great care has been taken to ensure the accuracy of
Any control replacement ................................................................................................ 0.5 0.5 the information in the Extended Warranty section of
Actuator replacement ..................................................................................................... 1.0 1.0 the Residential and Light Commercial Products
Misc. Section Handbook; however, the information in the Trane
Solve noise complaint7 ................................................................................................ 0.5 0.5 Optional Extended Warranty handbook supersedes
Diagnostic Charge1 ...................................................................................................... 0.5 0.5 all information contained herein.
Multiple Components ..................................................................................................... 0.5 0.5
NOTES: 1 Diagnostic calls will be paid only on covered repairs. (Not paid on maintenance or dirty sock)
2 All times allowed requiring entry or repair to refrigerant circuit includes evacuation, recharge and drier change.
3 All times allowed for compressor replacement includes drier change, cleanup, evacuation and recharge.
4 Crane allowance up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of crane charge is allowed on systems applied in a commercial application or if the
equipment is 4 tons or greater. (Not allowed on parts only warranty.)
5 Sales tax, if applicable, will be reimbursed to the dealer.
6 All times not shown for specific tasks - Call 1-800-554-6413.
7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hours plus the time
allowed for the component replacement/repair. Explain fully.
8 Pay only one (1) man per job.
9 All invoices must be received within sixty (60) days of the repair.
TRAVEL TIME (Flat Rate Dealers cannot charge Travel Time):
Mileage (any distance) - add 1 hour based on your established labor rate.
Two (2) trip charges are allowed for major component replacement (compressor, outdoor coil, evaporator coil, switch over valve, burners, or heat exchanger).
ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.
Consumer Benefits
Peace of Mind
• No unexpected out-of-pocket expenses*
• Repair/Replace option allows consumer to apply repair cost toward
purchase price of new equipment
• Hedge against inflation (parts, labor and refrigerant)
Assurance of Commitment
• Trane dealer assigned to their agreement has up-to-date
knowledge of equipment and service techniques
• Extended Warranty is transferrable to subsequent homeowners
should the original owner sell their home
• Cost effective as compared to other Extended Warranties
(i.e., appliances, consumer electronics, automobiles)
Dealer Benefits
• Labor Coverage after 90th Day (lower labor reserves)
• Extended Warranty contracts assign selling dealer as servicer of
record which potentially “locks in” customer for the life of the
warranty
• Provides “In Warranty” parts markup (revenue opportunity)
• Additional profit opportunity by selling the Extended Warranty
(gross profit becomes close to net profit)
• Repair/Replace option allows consumer to apply repair costs
toward purchase price of new equipment
• Dealer provides more comprehensive coverage which improves
customer satisfaction with dealer and Trane
• Encourages the sale of Maintenance Agreements
• Commercial Product up to 25 tons can be covered up to 10 years
for parts and labor
• New construction dealer can include Extended Warranties, captur-
ing customers they normally don’t see (if agreement is put in the
builder’s name, the agreement can be transferred to the new
homeowner at no charge)
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the Residential and Light
Commercial Products Handbook; however, the information in the Trane Optional Extended Warranty handbook supersedes all
information contained herein.
*Covers labor, refrigerant, diagnostic, and parts, subject to product coverage and terms and conditions.
Example:
Assumptions:
• Unit is 4 years old and an Evaporator Coil must be replaced
• Evaporator Coil is an in-warranty part that would normally cost $500
if purchased
• Dealer has $70/hr. labor rate (time and material, not flat rate)
• 7 lbs. of R410A needed for repair (dealer cost is $11/lb.)
Consumer has No
Consumer has 10-Yr. P&L, Lbr. Opt. 3 Extended Warranty Difference
EW Pays Dealer Consumer Pays Dealer
Labor Travel (2 hrs.) $ 140.00 $ 140.00 $ -
Diagnostic (.5 hrs.) $ 35.00 $ 35.00 $ -
Repair (4.5 hrs.) $ 315.00 $ 315.00 $ -
Total $ 490.00 $ 490.00 $ -
• In the above example, even with a 10-year Limited Warranty on parts, the consumer still paid $644 for a
coil replacement, and you made only $77 in profit on parts. With the Extended Warranty, the consumer
pays nothing for the repair and you made an additional $250 in profit on parts
Selling Story:
• The Extended Warranty should be offered at time of sale (can be
included with financing)
• Use the Extended Warranty Sales Brochure, Pub. No. 26-1016 and the
consumer benefits on the reverse side
• Point out that Limited Warranty does not cover refrigerant or labor
• If the Extended Warranty is “included” in the total proposal, it is much easier
to sell
• If you are in a “regulated” state, you must provide the actual purchase price
(not to be less than your actual cost) on the Extended Warranty Application.
This amount will appear on the consumer’s agreement (see your Extended
Warranty Handbook for more information on selling Extended Warranties in
“regulated” states)
Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of
the Residential and Light Commercial Products Handbook; however, the information in the Trane Optional
Extended Warranty handbook supersedes all information contained herein.
*All 15 digit model numbers starting with 2 or 4 and EXISTING NEW UNIT USE
YCC, YCX, TCC, TCX, WCC and WCX.
CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54
56 1/8"
53 1/8" I.D.
19 1/2" I.D. 28 7/8" I.D.
10"
Weight in Lbs.
Shipping
61 21/32" Weight
155
41 7/8"
56 1/8" Operating
110
EXISTING Weight
CURB
SA
ROOF
VIEW “A”-”A” RA
EXISTING CURB
BAYCURB033
41 7/8"
38 7/8" I.D.
20" I.D.
“A” 57 21/32"
31"
“B”
35" “B”
“A”
EXISTING
CURB
ROOF
VIEW “B”-”B”
*All 15CC
digit C
modelCC C
numbers CC
starting withC2 or 4 and EXISTING NEW UNIT USE
YCC, YCX, TCC, TCX, WCC and WCX. CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54
*All 15 digit model numbers starting with 2 or 4 and EXISTING NEW UNIT USE
YCC, YCX, TCC, TCX, WCC and WCX. CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54
Insul.
Deck
Full perimeter fit curb for Impack models with insulated deck pan
Full perimeter fit curb for Impack models with insulated deck pan
From Dwg. 21C662034 Rev. 2
Table AC/IN-9-A Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
R-410 R-22 Used With
Model Number Model Numbers 13 SEER Coils
4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXC,CXC,CXA -018
4AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -024
4AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -025
4AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -030
4AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -031
4AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -036
4AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -037
4AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -042
Expansion Valve TXV 4AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -043
Cooling/Heat Pump Kit 4AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -048
4AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -049
General Information 4AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -050
This Thermostatic Expansion Valve Kit may 4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -060
be used on any indoor air handler or coil that 4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -061
is equipped with a current thermostatic
expansion valve with an internal check valve Table AC/IN-9-B Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
and mechanical fittings This kit can be used R-410 R-22 Used With
Model Number Model Number Horizontal Flat Coils
on split system heat pumps and air condi-
4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXF -018
tioning systems.
4AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXF -033
4AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXF -041
Thermostatic Expansion Valve Kits can be
4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -054
field installed to fit a variety of sizes and
4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -063
combinations of air handlers or coils and
outdoor units to optimize performance. Table AC/IN-9-C Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
R-410 R-22 Used With
This TXV kit will normally be used when a Model Model High Efficiency
different refrigerant is going to be used in the Number Number Aluminum Coils
air handler or coil than what is indicated on 4AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -025
the unit name plate. The TXV type must al- 4AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -031
ways match the refrigerant type used in the 4AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -036
outdoor unit. 4AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -037
4AYTXVH3B3654A 2AYTXVH3B5454A 2/4TXC -054
Kit Identification 4AYTXVH3B6165A 2AYTXVH3B6161A 2/4TXC -061
The first character in the kit model number 4AYTXVH3B6165A 2AYTXVH3B6565A 2/4TXC -065
indicates the type of refrigerant that the
valve can be used with. Example a Table AC/IN-9-D Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
2AYTXVH3D1830A is an R-22 valve. R-410 R-22 Used With
Number Numbers Air Handlers
The “3” in the eighth digit in the model 4AYTXVH3D1831A 2AYTXVH3D1830A 2TFB -018-030
number identifies the valve as a non-bleed 4AYTXVH3D1831A 2AYTXVH3D1830A 2/4TFE -025
TXV. When this TXV kit is installed with an
outdoor unit that contains a reciprocating 4AYTXVH3D1831A 2AYTXVH3D1830A 2/4TEC -018-030
compressor, the outdoor unit must be — 2AYTXVH3D3636A 2/4TEC -036
equipped with a hard start kit if not factory 4AYTXVH3D3642A — 2/4TEC -036-042
installed. If the outdoor unit contains a scroll — 2AYTXVH3D4260A 2/4TEC -042-060
compressor, the installation of a hard start 4AYTXVH3D4863A — 2/4TEC -048-060
kit may be required.
4AYTXVH3D1831A 2AYTXVH3D1830A 2TEH -018-030
Inspection — 2AYTXVH3D3636A 2TEH -036
Check carefully for any shipping damage. 4AYTXVH3D3642A — 2TEH -036-042
Any such damage must be reported and — 2AYTXVH3D4260A 2TEH -042-060
claims made against the transportation 4AYTXVH3D4863A — 2TEH -048-060
company immediately. Any missing parts
should be reported to your supplier at once 4AYTXVH3D1831A 2AYTXVH3D1830A 2TGB -018-036
and replaced with authorized parts only. 4AYTXVH3D3642A — 2TGB -042
— 2AYTXVH3D4260A 2TGB -042-048
4AYTXVH3D4863A — 2TGB -048
Table AC/IN-10-C — Heat Pump Non- Bleed TXV Kits (also for cooling) – Dual Direction Flow
Liquid Line Gas Line
Model Used With Connection Connection Shipping
Number AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant
TAYTXVH0B3C 1-11/2 Ton 1
/4 5
/8 3 R-22
2-21/2 Ton 5 3
TAYTXVH0C3C
TAYTXVH0E3C
TAYTXVH0G3C
3-31/2 Ton
4 Ton
PHASED OUT
3
3
/16
/8
/8
7
1
/4
/8
1 /8
3
3
3
R-22
R-22
R-22
3
TAYTXVH0H3C 5-6 Ton /8 11/8 3 R-22
Table AC/IN-10-D— Cooling/Heat Pump Non-Bleed TXV Kits - Dual Direction Flow*
Expansion Valve TXV Liquid Line Gas Line
Heat Pump Kit* Model Used With Connection Connection Shipping
Number AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant
21/2 -3 Ton
PHASED OUT
3
TAYTXVH0D3C /8 11/8 2 R-22
3
TAYTXVH0G3C 4 -5 Ton /8 11/8 2 R-22
* Used with TXH coils only where approved for use with 2 compressor systems.
The nine digit serial numbers on all Trane central air conditioning and heating
products are employed to identify the year and fiscal week of product manufacture.
Fiscal week of manufacture ............... Second and third digit ............... M124X04CF
1 Beginning with 1/1/96 (L01) Ducane oil furnace production uses same date
code method as gas furnace. Prior to 1/1/96 Ducane serial number used
last four digits = date code, example HA1234569540 1995, 40th week.
Example: 123456-8 5 4 0
This page contains limited data for an unskilled user to fully determine if the application will work or to
select required accessories. Please refer to publication #22-3317-01 for complete details and examples.
For complete equipment / combination
Effective 1/1/06 AC/IN-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Refrigerant HFC 410A (R-410A)
Tables contain no allowances for vertical lift!
Table AC/IN-17-A
Table AC/IN-17-B
TTA Liquid Suction Applicable line length and rise:: x=total line length (hor+vert) : y=total line rise
090a 1/2 1- 3/8
120a 1/2 1- 3/8 For 0<=x<=50: x=y
120b 3/8 1- 1/8 For 50<x<=150: y=62.5-.25x
120c 1/2 1- 3/8 50 Call Trane for review
Total
150b 1/2 1- 3/8
Rise
180b 1/2 1- 3/8 25 Acceptable
180c 5/8 1- 5/8
240b 1/2 1- 3/8 50 Total Length 150
TWA Liquid Suction Applicable line length and rise:: x=total line length (hor+vert) : y=total line rise
090a 1/2 1- 3/8
120a 1/2 1- 3/8 for 0<=x<=50: x=y
180b 1/2 1- 3/8 For 50<x<=150: y=62.5-.25x
240b 1/2 1- 3/8 Same as TTA
Explanation:
If the total refrigerant line length is equal to or less than 50 feet, the length of the vertical riser may be = to the total length.
If the total refrigerant line length is greater than 50 feet, then the maximum length of vertical pipe must be figured by using
the second formula.
Example:
Given:
Total refrigerant piping length = 150 feet
Required:
Determine the maximum allowable vertical pipe length.
Solution:
First, determine if the total length is within maximum allowable rules, then determine the maximum vertical length.
The total length exceeds 50 feet and is equal to 150 feet; therefore, the maximum vertical length
= 62.5 ft-(.25 X 150 ft)
= 62.5 ft -37.5 ft
= 25 ft maximum vertical length
10 #12 Copper
or
15 #10 Aluminum
20
25
#10 Copper
30
or
35 #8 Aluminum
40 #8 Copper
or
REQUIRED BRANCH CIRCUIT AMPACITY
45
#6 Aluminum
50
55 #6 Copper
60 or
#4 Aluminum
65
70
#4 Copper
75 or
#2 Aluminum
80
85
90
95
#2 Copper
100 or
105
#0 Aluminum
110
115
120
125
130
50 100 150 200 250 300 350
Distance (power supply to load in feet (460V).
See National Electrical Code for Temperature corrections and other variables. All wiring must comply with Local Codes
NO V No V
Infiltration or Ventilation CFMo 2. CFMo = 2. CFMo =
60 min./hr. 60 min./hr.
Total Heat (HT) Btuh 5. HT = CFMT x 4.5 x (h1 – h2) = Btuh 6. HT = CFMT x 4.5 x (h2 – h1) = Btuh
Sensible Heat (HS) Btuh 7. HS = CFMT x 1.08 x (T1 – T2) = Btuh 8. HS = CFMT x 1.08 x (T2 – T1) = Btuh
Latent Heat (HL) Btuh 9. HL = CFMT x .68 x (W1 – W2) = Btuh 10. HL = CFMT x .68 x (W2 – W1) = Btuh
CFMo CFMo
Entering Air Temperature (T1) °F. D.B. 11. T1 = t1 + x (t2 – t1) = °F.D.B. 1 12. T1 = t1 – x (t1 – t2) = °F.D.B. 2
CFMT CFMT
(Mixed Air)
1 If duct heat gain is a factor, add to T1: 2 If duct heat loss is a factor, subtract from T1:
Duct Heat Gain (Btuh) Duct Heat Loss (Btuh)
CFMT x 1.08 CFMT x 1.08
Btu/lb. HT HT
Enthalpy – Leaving Air (h2) 17. h2 = h1 – = Btu/lb. dry air 18. h2 = h1 + = Btu/lb. dry air
dry air CFMT x 4.5 CFMT x 4.5
19. Refer to Enthalpy Table and read W.B. temperature 20. Refer to Enthalpy Table and read W.B. temperature
Leaving Air W.B. Temperature °F.W.B.
corresponding to enthalpy of leaving air (h2) (see #17). corresponding to enthalpy of leaving air (h2) (see #18).
Heat Required to Evaporate
Water Vapor Added to Btuh 21. HL = CFMo x .68 (W3 – Wo) = Btuh 22. HL = CFMo x .68 (W3 – Wo) = Btuh
Ventilation Air
Excess Latent Capacity
HL loss Btuh (see #22)
Humidification Requirements
Lbs.
water/hr.
23.
( Moisture )
Make up = of System x % Run Time
1060 Btu/lb.
= lbs./hr.
(
24. Make up =
Moisture ) 1060 Btu/lb.
= lbs./hr.
* See Enthalpy of air (Total Heat Content of Air) Table for exact values.
Model
Family 55oF 45oF 30oF OoF
As As
XL19i AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped Shipped
As As
XL16i AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped Shipped
As As
XL15i AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped Shipped
XL14i As
TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
XR14 As
TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
As Quick Start Solenoid
XR13 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
Shipped Kit Valve 3
As
XR12 - R-410A TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped
As Quick Start Solenoid
XR12 - R-22 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
Shipped Kit Valve 3
2TTA3 / As 3 phase Solenoid
2TTA2 / 2TTA0 shipped
TXV7 AY28X079 TXV-NB7 ** BAYLOAM103 TXV-NB 7 ** not needed Valve 3
2.5 to 5 Ton As Quick Start Solenoid
TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
XR11 Shipped Kit Valve 3
1.5 to 2 Ton As Quick Start Solenoid
TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB 7 BAYCCHT*
XR11 Shipped Kit8 Valve 3
As Quick Start Solenoid
XB13 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
Shipped Kit Valve 3
As Quick Start Solenoid
XB12 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
shipped Kit Valve 3
2.5 to 5 Ton As Quick Start Solenoid
TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
XB10 Shipped Kit Valve 3
For a detailed Application Bulletin on required accessories and wind shields for low
outdoor ambient operation, please contact your Territory Manager or Local FSR.
For complete equipment / combination
selections and installation instructions, please AC/IN-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Low Ambient Accessories
Heat Pump Models
Model
Family 55oF 45oF 30oF34 OoF34
As
XL19i As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
As
XL16i As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
As
XL15i As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
XL14i As
TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
XR14 As
TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
As Quick Start
XR13 TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
As
XR12 - R410A TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
As Quick Start
XR12 - R-22 TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Quick Quick
As Quick Start
XR11 TXV-NB7 Start AY28X084 TXV-NB7 Start BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Kit Kit
As Quick Start
XB13 TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Quick Quick
As Quick Start
XB12 TXV-NB7 Start AY28X084 TXV-NB7 Start BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Kit Kit
Quick Quick
As Quick Start
XB10 TXV-NB7 Start AY28X084 TXV-NB7 Start BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Kit Kit
2TWA3 / As 3 3
2TWA2 / 2TWA0 Shipped
TXV-NB7
phase
AY28X084 TXV-NB7
phase ** BAYLOAM103 TXV-NB7 ** 3 phase
Notes:
1 Scroll compressors unload during the off cycle and do not require hard start components due to refrigerant pressure differential. However, it is
recommended to install a start kit when operating below 30°F.
2 For all systems employing head pressure control, a non-bleed thermal expansion valve (NB-TXV) is required. All heat pump expansion valve accesso-
ries are non-bleed type. TWE060A has a factory installed bleed port TXV. If belt drive is preferred (TWE060A), it is recommended to change the TXV to
a non-bleed type.
3 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.
4 System indoor airflow shall be no less than 370 CFM / Ton.
5 Do not use solenoid valves with heat pump systems.
6 Check Product Data General Specification page in order to determine if the heat pump unit ships with required components such as crankcase heat or
start components.
7 If non bleed thermal expansion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start compo-
nents. Check Product Data for factory-installed components in order to determine if a quick start accessory is required.
* Please refer to Product Data.
** BAYCCHT (Crankcase Heater) is factory installed.
For a detailed Application Bulletin on required accessories and wind shields for low
outdoor ambient operation, please contact your Territory Manager or Local FSR.
For complete equipment / combination
Effective 1/1/06 AC/IN-24 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Wind Shields
Notes:
Minimum working clearance must be in compliance with the National Electric Code. Currently,
the minimum clearance between a wood or suitable grounding material type fence requires
minimum 3 feet. If other material is used to form the windshield, the minimum space may be
increased to 3.5 feet. Please consult the 2002 Edition of the National Electric Code, Article 110
for the most up to date information, please refer to the most current National Electric Code.