You are on page 1/ 366

Introduction

This is your Trane Residential and Light Commercial Products Handbook,


published in January, 2006.

This handbook was created to provide one easy-to-use source for


generalized information pertaining to 1 ton through 25 ton Trane products.
However, it should not be used to replace the comprehensive Trane Product
Data Catalogs. Product Data Catalogs contain critical and pertinent data not
found in this handbook.

This handbook does not contain data such as ARI system ratings,
performance tables, etc… If you require this information, you should always
refer to the most current Trane Product Data Catalog.

Effective immediately, this handbook will be published semi-annually.


Tentative print dates are set for July, 2006 and again in January, 2007. We
will attempt to maintain a ready supply of these printed catalogs in our
distribution warehouse, and you can reorder as often as you wish. The
Publication Number is shown on the back cover of this handbook. Reprints
made between January 2006 and June 2006 will not include any new/revised
information. This information will only become available in the July 2006
edition.

This handbook will, however, be updated quarterly on TraneNet™ and


ComfortSite™. If you do not have access, please consult with your Trane
distributor. This electronic information will subsequently be the most current
information available.

If you find information that needs to be corrected/updated or added, please


send your recommendations directly to:

Kaye Berry / Jeff Mondrik


Residential Product Support
Trane Residential Systems
Tyler, Texas 75701
[email protected] / [email protected]
(903) 581-9199 or (903) 509-7222 (Fax #s)

Thank you for the opportunity to provide you with an updated Trane handbook.

Effective 1/1/06
Contents

Model Nomenclature ................................................................................................. TOC-4


Split System Cooling
• Single Phase, 1½ through 5 Tons (2TTZ, 2TTX, 4TTX) ...................................... SC-1
• Single Phase, 1½ through 5 Tons (2TTR, 4TTR) ................................................. SC-3
• Single Phase, 1 through 5 Tons (2TTB, TTB) ...................................................... SC-7
• Three Phase, 2½ through 6 Tons (2TTA) ............................................................ SC-9
• Three Phase, 7½ through 20 Tons (TTA) .......................................................... SC-11
• ReliaTel™ Controls Protection/Operation Timings and Features ...................... SC-17
• ReliaTel™ Micro Control Operation with a Thermostat ...................................... SC-18
Split System Heat Pumps
• Single Phase, 1½ through 5 Tons (2TWZ, 4TWX, 2TWX) ................................... SH-1
• Single Phase, 1½ through 5 Tons (4TWR, 2TWR) .............................................. SH-3
• Single Phase, 1½ through 5 Tons (2TWB) ........................................................... SH-7
• Three Phase, 2½ through 6 Tons (2TWA) ........................................................... SH-9
• Three Phase, 7½ through 20 Tons (TWA) ......................................................... SH-11
Air Handlers/Heaters
• Convertibility Chart ............................................................................................... AH-1
• Air-Tite™ Features and Benefits .......................................................................... AH-2
• Single Phase, 1½ through 5 Tons (TWE-E, 4TEE) .............................................. AH-3
• Single Phase, 1½ through 5 Tons (2TEH) ........................................................... AH-4
• Single Phase, 1½ through 5 Tons (2/4TEC) ........................................................ AH-5
• Single Phase, 1½ through 4 Tons (2TGB) ........................................................... AH-6
• Single Phase, 1½ through 2½ Tons (2TFB, 2/4TFE) ........................................... AH-7
• Heaters for Split System and Convertible ............................................................ AH-8
• Single Phase, 1½ through 5 Tons (TWE-P, 2TEP, 4TEP) ................................. AH-11
• Single Phase, 1½ through 5 Tons (TWE-C) ....................................................... AH-12
• Single Phase, 1½ through 5 Tons (TWG) .......................................................... AH-13
• Single Phase, 1½ through 3 Tons (2TFB, 2TFE) ............................................... AH-14
• Single Phase 5-10 Tons, Three Phase 5-20 Tons (TWE) .................................. AH-15
Furnaces/Coils
• XV, XL, XT, XR, XB 90 Airflow Directions .......................................................... FUR-1
• XV, XL 90 Convertible (TUY, TDY, TUX, TDX) .................................................. FUR-2
This publication is for general reference
information only and is not intended for • XT, XR 90 Convertible (TUX, TDX) .................................................................... FUR-3
systems equipment / combination selections. • XR, XB 90 Convertible (TUX, TDX, TUC, TDC) ................................................. FUR-4
• XV, XL, XT, XR, XB 80 Airflow Directions .......................................................... FUR-7
For complete equipment / combination • XV, XL 80 Convertible (TUD, TDD) .................................................................... FUR-8
selections and installation instructions,
please refer to Product Data and Installers • XT, XR 80 Convertible (TUD, TDD) ................................................................... FUR-9
Guides. • XR, XB 80 Convertible (TUD, TDD, TUE, TDE) ............................................... FUR-10
• XV80 Variable Speed High Efficiency Oil Furnaces (THV, TLF, TLR, TDF) .... FUR-13
Products listed in this book are not always • XP80 High Efficiency Oil Furnaces (THV, TLF, TLR, TDF) ............................. FUR-14
carried in factory/distributor inventory, nor are
all products available through all distribution
• Quick Reference Charts ................................................................................... FUR-15
channels. Consult your Distributor for avail- • Split System Cased Heat Pump and Cooling Coils (2/4TXC, 2/4TXF) ............ FUR-19
ability and shipping information. • Split System Cased Heat Pump and Cooling Coils (2/4TXC, 2CXC) ............... FUR-20
• Split System Cased/Uncased Cooling Only Coils (4CXC, 2/4CXA) ................. FUR-21
Since Trane has a policy of continuous product
improvement, it reserves the right to change
• Split System Cased/Uncased Heat Pump and Cooling Coils
design and specification without notice. (TXC, RXC, RXA, TXE) ................................................................................. FUR-22
• Split System Cased Heat Pump and Cooling Coils (TXC, RXH, TXH) .............. FUR-23
The Manufacturer’s Limited Warranties on • Split System Cased/Uncased Heat Pump and Cooling Coils (TXA, CCB, CUB) FUR-24
current residential split condensing units and • Coil Enclosures ................................................................................................. FUR-25
systems installed on or after 10/01/2001 • Furnace/Coils Matrix ......................................................................................... FUR-26
where product is manufactured after January Indoor Air Quality
1, 2000. The new Manufacturer’s Limited
• TRANE CleanEffects™ Air Cleaner and Upgrade Kits (TFD) .......................... IDAQ-1
Warranties are not retroactive to installations
• Perfect Fit™ Air Cleaner (TFE) ........................................................................ IDAQ-2
prior to 10/01/2001 or units manufactured
before 2000 (see The Limited Warranty • Perfect Fit™ Air Cleaner (TFM, TFP) ............................................................... IDAQ-3
Guidelines for more information, 26-1000-14). • Perfect Fit ™ Filter Accessories ....................................................................... IDAQ-4
• Humidifiers Fan Powered and Bypass ............................................................ IDAQ-7
• FreshEffects™ Energy Recovery Ventilator (TERV) ..................................... IDAQ-10
Package Cooling
• Convertible, 1½ through 5 Tons (4TCX) .............................................................. PC-1
• Convertible, 1½ through 5 Tons (4TCC) .............................................................. PC-6
For complete equipment / combination
selections and installation instructions, please TOC-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
© 2006 American Standard All Rights Reserved
Contents

Package Cooling (continued)


• Convertible, 2 through 5 Tons (TCY, TCX) ........................................................ PC-13
• Convertible, 1½ through 5 Tons (TCP, TCC) ..................................................... PC-14
• Convertible, 1½ through 5 Tons (TCY, TCX, TCP, TCC) .................................. PC-15
• Electric Heat, 2 through 4 Tons (TCK) ............................................................... PC-19
• Manufactured Housing, 2½ through 4 Tons (TCM) ............................................ PC-21
• Over/Under, 2 through 5 Tons (TCH) ................................................................. PC-22
• Precedent™ Convertible, 3-10 Tons Features ................................................... PC-24
• Precedent™ Convertible, 3-10 Tons (TSC) ....................................................... PC-25
• Precedent™ Convertible, 3-10 Tons (THC) ....................................................... PC-27
• Light Commercial New Model Quick Reference ................................................. PC-33
• ReliaTel™ Controls for Precedent™ 13 SEER and Voyager™ ......................... PC-35
• Micro Control for Precedent™, Precedent™ 13 SEER and Voyager™ ............. PC-36
• Precedent™ Convertible, 3-5 Tons 13 SEER R-22 (THC) ................................. PC-38
• Voyager™ with ReliaTel™ Controls, 12½ through 25 Tons (TCD) .................... PC-43
• Voyager™ with ReliaTel™ Controls, 12½ through 25 Tons (TCH) .................... PC-44
Package Heat Pump
• Convertible, 1½ through 5 Tons (2/4WCX) .......................................................... PH-1
• Convertible, 1½ through 5 Tons (2/4WCC) .......................................................... PH-6
• Convertible, 2 through 5 Tons (WCZ, WCY, WCX) ........................................... PH-13
• Convertible, 1½ through 5 Tons (WCP, WCC) ................................................... PH-14
• Convertible, 1½ through 5 Tons (WCZ, WCY, WCX, WCP, WCC) ................... PH-15
• Dual Fuel with Auxiliary Gas Heat (DCY) ........................................................... PH-16
• Electric Heat, 2 through 3½ Tons (WCK) ........................................................... PH-20
• Over/Under 2 through 5 Tons (WCH) ................................................................. PH-21
• Manufactured Housing, 2½ through 3½ Tons (WCM) ....................................... PH-23
• Precedent™ Convertible, 3-10 Tons Features ................................................... PH-24
• Precedent™ Convertible, 3-10 Tons (WSC) ...................................................... PH-25
• Light Commercial New Model Quick Reference ................................................. PH-29
• Voyager™ with ReliaTel™ Controls, 12½ through 20 Tons (WCD, WCH) ........ PH-30
Package Gas/Electric
• Convertible, 2 through 5 Tons (2YCX) ................................................................. PG-1
• Convertible, 1½ through 5 Tons (4YCX) .............................................................. PG-2
• Convertible, 2 through 5 Tons (2YCC) ................................................................. PG-7
• Convertible, 1½ through 5 Tons (4YCC) .............................................................. PG-8
• Convertible, 1½ through 5 Tons (YCZ, YCY, YCX) ............................................ PG-14
• Convertible, 2 through 5 Tons (YCX, YCP) ........................................................ PG-15
• Convertible, 1½ through 5 Tons (YCC) .............................................................. PG-16
• Convertible, 2 through 5 Tons (YCZ, YCY, YCX) ............................................... PG-19
• Convertible, 1½ through 5 Tons (YCP, YCC) ..................................................... PG-20
• Precedent™ Convertible, 3-10 Tons Features ................................................... PG-21
• Precedent™ Convertible, 3-10 Tons (YSC) ....................................................... PG-22
• Precedent™ Convertible, 3-10 Tons (YHC) ....................................................... PG-28
• Light Commercial New Model Quick Reference ................................................. PG-33
• Precedent™ Convertible, 3-5 Tons 13 SEER R-22 Features ............................ PG-37
• Precedent™ Convertible, 3-5 Tons 13 SEER R-22 (YHC) ................................ PG-38
• Voyager™ with ReliaTel™ Controls 12½ through 15 Tons (YCD) ..................... PG-43
• Voyager™ with ReliaTel™ Controls 17½ through 25 Tons (YCD) ..................... PG-44
• Voyager™ with ReliaTel™ Controls 12½ through 15 Tons (YCH) ..................... PG-45
• Voyager™ with ReliaTel™ Controls 17½ through 25 Tons (YCH) ..................... PG-46
Factory Installed Options
• Voyager™ Commercial Packaged Units 12½ through 25 Tons ..................... FIOPS-1
• Factory Installed Options Accessories ........................................................... FIOPS-2
• Factory Installed Options Matrix Pages ........................................................ FIOPS-10
Comfort Controls/Zone Sensors
• Comfort Control Definitions ............................................................................. CCZO-1
This publication is for general reference • Programmable 7 Day ....................................................................................... CCZO-2
information only and is not intended for • Programmable 5/2 Day .................................................................................... CCZO-4
systems equipment / combination • Non-Programmable ......................................................................................... CCZO-5
selections. • Remote Sensors .............................................................................................. CCZO-7
For complete equipment / combination
Effective 1/1/06 TOC-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Contents

Comfort Controls/Zone Sensors (continued)


• Humidity Control .............................................................................................. CCZO-8
• Relay Hook-Up ................................................................................................ CCZO-8
• Indoor Fan Delay Relay Kit ............................................................................. CCZO-9
• Outdoor Thermostat Kit ................................................................................... CCZO-9
• Cooling Only and Heating Only ..................................................................... CCZO-10
• Single Stage .................................................................................................. CCZO-11
• Multiple Stage ................................................................................................ CCZO-12
• Heat Pump ..................................................................................................... CCZO-13
• Zone .............................................................................................................. CCZO-14
• ComfortLink™ System ................................................................................... CCZO-15
• Integrated Zone™ System Assembly and Accessories ................................ CCZO-15
• Sensors for ComfortLink™ ............................................................................ CCZO-16
• Integrated Zone™ System Dampers ............................................................. CCZO-17
• Zone Sensor Unit Installation ........................................................................ CCZO-18
• Micro Controls Zone Sensors ........................................................................ CCZO-19
• Electronic Programmable Zone Sensors for ReliaTel™ Units ...................... CCZO-19
• Electronic Zone Sensors for ReliaTel™ Units ............................................... CCZO-20
• Integrated Comfort™ Systems Sensors for ReliaTel™ Units ....................... CCZO-21
Ductless Mini-Splits
• Ductless Air Conditioners (MCW) ...................................................................... MINI-1
• Ductless Outdoor Units (TTK) ........................................................................... MINI-2
Packaged Terminals/Unit Heaters
• Packaged Terminal Air Conditioners and Heat Pumps ............................. PTAC/UH-1
• Indoor Gas Heating Products Description ................................................. PTAC/UH-4
• Indoor Units ............................................................................................... PTAC/UH-6
• Model S – Horizontal Units ...................................................................... PTAC/UH-18
• Model P – Vertical Units .......................................................................... PTAC/UH-26
• Electric Unit – Voltage Control ................................................................. PTAC/UH-31
• Electric Unit – Control Options ................................................................ PTAC/UH-33
• Electric Unit, Hose Down Corrosion Resistant ........................................ PTAC/UH-36
• Electric Unit, UHXA ................................................................................. PTAC/UH-38
• Electric Ceiling Mounted Unit .................................................................. PTAC/UH-40
• Electric Wall Mounted Units ..................................................................... PTAC/UH-42
• Electric Wall Fin ....................................................................................... PTAC/UH-46
Extended Warranties
• Labor Options ...................................................................................................... WA-1
• Standard Servicer Guidelines .............................................................................. WA-2
• Expanded Servicer Guidelines ............................................................................ WA-3
• Optional Extended Warranty Benefits ................................................................. WA-4
Accessories/Information
• Roof Curbs (BAYCURB050A, BAYCURB051A) ............................................. AC/IN-1
• Roof Curb Adaptors (BAYADAP050A) ............................................................ AC/IN-2
• Roof Curb Adaptors (BAYADAP051A) ............................................................ AC/IN-3
• Roof Curb Adaptors (BAYADAP052A) ............................................................ AC/IN-4
• Roof Curb Adaptors (BAYADAP053A) ............................................................ AC/IN-5
• Roof Curb Adaptors (BAYADAP054A) ............................................................ AC/IN-6
• Impack™ Roof Curbs (BAYCURB030A, BAYCURB038A) ............................. AC/IN-7
• Impack™ Roof Curbs (BAYCURB033A, BAYCURB034A) ............................. AC/IN-8
• Thermal Expansion Valves .............................................................................. AC/IN-9
• Refrigerant Line Sets ..................................................................................... AC/IN-11
• Base Pan Sizes ............................................................................................. AC/IN-12
• Equipment Date Identification ........................................................................ AC/IN-15
• Refrigerant ..................................................................................................... AC/IN-16
• Split System Refrigerant Piping, 7½-20 Ton (HCFC-22) ............................... AC/IN-20
• Branch Circuit Wire Sizing Table/Heater De-Rating Chart ............................ AC/IN-21
• Basic Air Conditioning Formulas ................................................................... AC/IN-22
• Low Ambient Accessories, Cooling Models ................................................... AC/IN-23
• Low Ambient Accessories, Heat Pump Models ............................................. AC/IN-24
• Wind Shields .................................................................................................. AC/IN-25
For complete equipment / combination
selections and installation instructions, please TOC-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Commercial Condensing Units


Outdoor Units Cooling and Heat Pump

Air Handler -
Residential
Accessories

For complete equipment / combination


Effective 1/1/06 TOC-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Air Handler - Air Handler/


Residential Electric Furnace
Heaters

Furnaces
15 - Digit

Air Handler -
Commercial

For complete equipment / combination


selections and installation instructions, please TOC-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Heat Pump/
Gas Furnaces Cooling Coils

Oil Furnaces

Oil Furnace
Accessories

For complete equipment / combination


Effective 1/1/06 TOC-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Model
Nomenclature

TRANE
Furnace Coils CleanEffects™
Whole House
Air Cleaner

Perfect Fit™
Air Cleaner
TXV Kits

Perfect Fit™ Filter


Accessories

For complete equipment / combination


selections and installation instructions, please TOC-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Humidifiers Humidifier
Controls

Energy
Humidifier Recovery
Accessories Ventilator
(ERV)

For complete equipment / combination


Effective 1/1/06 TOC-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Model
Nomenclature
Package Units Package Units
15 - Digit

For complete equipment / combination


selections and installation instructions, please TOC-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Precedent™
Units

For complete equipment / combination


Effective 1/1/06 TOC-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Precedent™
13 SEER Units

For complete equipment / combination


selections and installation instructions, please TOC-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Ductless
Comfort Outdoor Units
Controls

Ductless
Air Conditioners
Integrated Zone™
System

For complete equipment / combination


Effective 1/1/06 TOC-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Packaged Indoor Gas


Terminals Heating Units

For complete equipment / combination


selections and installation instructions, please TOC-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Horizontal Model S
Blower Assembly Unit Heater

For complete equipment / combination


Effective 1/1/06 TOC-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Model P Electric Heaters


Unit Heater Model UHEC

Electric Wall
MountedUnit
Heaters
Model UHWA

For complete equipment / combination


selections and installation instructions, please TOC-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Model
Nomenclature

Electric Hose Down Electric Ceiling


Unit Heater Mounted Heaters
Model UHRA Model UHCA

Electric Explosion
Proof Unit Heaters
Model UHXA

Electric
Architectural
Wall Heaters
Model UHAA

For complete equipment / combination


Effective 1/1/06 TOC-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1½ through 5 Tons

Table SC-1-A — XL19i Split System Cooling — Single Phase


Nom. Cap. Uncrated Shipping Line Size
Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.
7 3
2TTZ9030B1000A 200-230/1/60 30,000 TXV-NB 50 37 34 439 72 18 30 /8 /8
7 3
2TTZ9036B1000A 200-230/1/60 36,000 TXV-NB 50 37 34 436 74 22 35 /8 /8
2TTZ9048B1000A 200-230/1/60 48,000 TXV-NB 50 37 34 444 74 25 40 11/8 3
/8
2TTZ9060B1000A 200-230/1/60 60,000 TXV-NB 50 37 34 448 73 37 60 11/8 3
/8
Note: Because of limited capabilities, please refer to product data for approved combinations.
XL19i
Table SC-1-B — XL16i Split System Cooling — Single Phase
Nom. Cap. Uncrated Shipping Line Size
Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 5
4TTX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 254 73 12 20 /8 /16
3 3
4TTX6036B1000A 230/1/60 36,000 TXV-NB 42 37 34 288 72 24 40 /4 /8
7 3
4TTX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 312 74 29 50 /8 /8
7 3
4TTX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 356 74 35 60 /8 /8

XL16i
Table SC-1-C — XL15i Split System Cooling — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TTX5024A1000A 208/230/1/60 24,000 TXV-NB 46 37 34 283 72 14 20 /4 /16
3 5
2TTX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 284 74 16 25 /4 /16
7 3
2TTX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 300 72 18 30 /8 /8
7 3
2TTX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 307 73 23 35 /8 /8
2TTX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 337 72 26 40 11/8 3
/8

XL15i Table SC-1-D — XL14i Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTX4018B1000A 200-230/1/60 18,000 TXV-NB 40 33 30 220 73 10 15 /8 /4
3 5
2TTX4024B1000A 200-230/1/60 24,000 TXV-NB 40 33 30 236 73 11 15 /4 /16
3 5
2TTX4030B1000A 208-230/1/60 30,000 TXV-NB 40 33 30 244 74 18 30 /4 /16
7 3
2TTX4036B1000A 208-230/1/60 36,000 TXV-NB 44 33 30 248 72 20 30 /8 /8
7 3
2TTX4042B1000A 208-230/1/60 42,000 TXV-NB 46 37 34 289 75 24 40 /8 /8
2TTX4048B1000A 208-230/1/60 48,000 TXV-NB 50 37 34 306 75 28 45 11/8 3
/8
XL14i 2TTX4060B1000A 208-230/1/60 60,000 TXV-NB 50 37 34 354 75 34 50 11/8 3
/8

Table SC-1-E — XL14i Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TTX4018B1000A 200-230/1/60 18,000 TXV-NB 40 33 30 236 74 10 15 /2 /4
5 5
4TTX4024B1000A 200-230/1/60 24,000 TXV-NB 40 33 30 239 74 13 20 /8 /16
3 5
4TTX4030B1000A 208-230/1/60 30,000 TXV-NB 40 33 30 242 71 20 30 /4 /16
3 3
4TTX4036B1000A 208-230/1/60 36,000 TXV-NB 44 33 30 255 71 21 35 /4 /8
3 3
4TTX4042B1000A 208-230/1/60 42,000 TXV-NB 46 37 34 297 74 25 40 /4 /8
7 3
4TTX4048B1000A 208-230/1/60 48,000 TXV-NB 50 37 34 310 74 27 45 /8 /8
XL14i 4TTX4060C1000A 208-230/1/60 60,000 TXV-NB 50 37 34 360 74 35 60 7
/8 3
/8
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SC-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1½ through 5 Tons

XL19i XL16i XL15i XL14i XL 14i


Table SC-2-A — Features (2TTZ9) (4TTX6) (2TTX5) (2TTX4) (4TTX4)
• SEER’s up to .......................................................................................................... 19.50 17.15 16.25 15.00 15.00
• Climatuff™ compressor ........................................................................................ 2 1 - staged ✔ ✔ ✔
• Comfort”R”™ mode approved ............................................................................. ✔ ✔ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ............................................. ✔ ✔ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & .............................................................. ✔ ✔ ✔ ✔ ✔
refrigerant connections with full coil protection
• Spine Fin™ coil ..................................................................................................... ✔ ✔ ✔ ✔ ✔
• Weatherguard™ II top .......................................................................................... ✔ ✔ ✔ ✔ ✔
• Compressor sound enclosure ................................................................................ ✔ ✔ ✔ ✔ ✔
• Compressor sump heat - factory installed .............................................................. 2½-5 5 2-4 1½-2 & 3½-5 1½-2
• Factory supplied charge ......................................................................................... R-22 R-410A R-22 R-22 R-410A
• Glossy corrosion resistant finish ............................................................................ ✔ ✔ ✔ ✔ ✔
• High pressure switch .............................................................................................. — ✔ — — ✔
• Internal high / low pressure & temperature protection ............................................ ✔ ✔ ✔ ✔ ✔
• Liquid line filter drier - factory installed ................................................................... ✔ ✔ ✔ ✔ ✔
• Quick start kit-factory installed ............................................................................... 2½-5 5 — 1½-2 & 5 1½-2 & 5
• Seacoast shield - factory installed .......................................................................... ✔ ✔ ✔ ✔ ✔
• Tarpaulin gray cabinet ............................................................................................ ✔ ✔ ✔ ✔ ✔
• 10-year limited warranty on compressor, ............................................................... ✔ ✔ ✔ ✔ ✔
outdoor coil & parts (Residential)
• Extended warranties available ............................................................................ ✔ ✔ ✔ ✔ ✔

Table SC-2-B — Optional Accessories


AY28X079 ..................... Evaporator defrost control kit ............................................. ✔ ✔ ✔ ✔ ✔
BAYCCHT301 ............... Crank Case Heater Kit (Scroll Compressors) ................... — 2-4 — 2½-3 2½-5
BAYECMT001 ............... Extreme Condition Mounting Kit ........................................ ✔ ✔ ✔ ✔ ✔
BAYISLT101 .................. Rubber Isolators ................................................................. ✔ ✔ ✔ ✔ ✔
BAYKSKT260 ............... Quick start kit (21/2 - 4 ton) (Scroll Compressors) ............. — 2-4 2-4 2½-4 2½-4
BAYLEGS002 ............... Snow Legs - Base and Cap 6" High (Black) ...................... ✔ ✔ ✔ ✔ ✔
BAYLEGS003 ............... 4" Extension (Black) ........................................................... ✔ ✔ ✔ ✔ ✔
TAYASCT501A12 ...... Anti-Short Cycle Timer ....................................................... ✔ ✔ ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section


1 Not for use with programmable thermostats.
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SC-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1½ through 5 Tons

Table SC-3-A — XR14 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 206 76 10 15 /8 /4
3 5
2TTR4024A1000A 200-230/1/60 24,000 TXV-NB 33 33 30 225 76 11 15 /4 /16
3
2TTR4030A1000A 208-230/1/60 30,000 TXV-NB 37 33 30 232 75 18 30 /4 5/16
7 3
2TTR4036A1000A 208-230/1/60 36,000 TXV-NB 37 33 30 236 76 20 30 /8 /8
7 3
2TTR4042A1000A 208-230/1/60 42,000 TXV-NB 37 37 30 269 78 24 40 /8 /8
XR14 2TTR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 285 77 28 45 1 1/8 3/8
2TTR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 336 79 34 50 1 1/8 3/8

Table SC-3-B — XR14 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TTR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 222 75 10 15 /2 /4
5 5
4TTR4024A1000A 200-230/1/60 24,000 TXV-NB 33 33 30 225 76 13 20 /8 /16
3 5
4TTR4030A1000A 208-230/1/60 30,000 TXV-NB 33 33 30 228 74 20 30 /4 /16
3 3
4TTR4036A1000A 208-230/1/60 36,000 TXV-NB 37 33 30 240 74 21 35 /4 /8
3 3
4TTR4042A1000A 208-230/1/60 42,000 TXV-NB 37 37 34 273 76 25 40 /4 /8
7 3
4TTR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 285 76 27 45 /8 /8
XR14 4TTR4060B1000A 208-230/1/60 60,000 TXV-NB 41 37 34 335 77 35 60 7
/8 3
/8

Table SC-3-C — XR13 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTR3018A1000A 200-230/1/60 18,000 TXV-NB 26 29 26 180 74 8 15 /8 /4
3 5
2TTR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 195 76 12 20 /4 /16
3
2TTR3030A1000A 200-230/1/60 30,000 TXV-NB 33 33 30 226 74 13 20 /4 5/16
7 3
2TTR3036A1000A 208-230/1/60 36,000 TXV-NB 33 33 30 221 75 18 30 /8 /8
7 3
2TTR3042A1000A 200-230/1/60 42,000 TXV-NB 33 37 34 284 77 21 35 /8 /8
2TTR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 309 76 25 40 1 1/8 3/8
XR13 2TTR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 305 76 32 50 1 1/8 3/8
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SC-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1½ through 5 Tons

XR 14 XR 14 XR 13
Table SC-4-A — Features (2TTR4) (4TTR4) (2TTR3)
• SEER’s up to ............................................................................................................................................. 14.00 14.00 14.00
• Climatuff™ compressor ........................................................................................................................... ✔ ✔ ✔
• Comfort”R”™ mode approved ................................................................................................................ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ................................................................................ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ........................ ✔ ✔ ✔
• Spine Fin™ coil ........................................................................................................................................ ✔ ✔ ✔
• Compressor sound enclosure ................................................................................................................... ✔ ✔ ✔
• Compressor sump heat - factory installed ................................................................................................. 1½-2,3½-5 1½-2 5
• Factory supplied charge ............................................................................................................................ R-22 R-410A R-22
• Glossy corrosion resistant finish ............................................................................................................... ✔ ✔ ✔
• High pressure switch ................................................................................................................................. — ✔ —
• Internal high / low pressure & temperature protection ............................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed ...................................................................................................... ✔ ✔ ✔
• Quick start kit - factory installed ................................................................................................................ 1½-2,5 1½-2,5 1½-2½,3½-5
• Tarpaulin gray cabinet ............................................................................................................................... ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ............................ ✔ ✔ ✔
• Extended warranties available ............................................................................................................... ✔ ✔ ✔

Table SC-4-B — Optional Accessories


AY28X079 .............. Evap. Defrost Control Kit .............................................................................................. ✔ ✔ ✔
BAYCCHT300 ........ Crankcase Heater Kit (Reciprocating Compressors) .................................................... — — 1½-2½,3½-4
BAYCCHT301 ........ Crankcase Heater Kit (Scroll Compressors) ................................................................. 2½-3 2½-5 3
BAYECMT001 ........ Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔
BAYISLT101 .......... Rubber Isolators ........................................................................................................... ✔ ✔ ✔
BAYKSKT260 ........ Start Kit (Scroll Compressors) ...................................................................................... 2½-4 2½-4 3
BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ................................................................. ✔ ✔ ✔
BAYLEGS003 ........ 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔
BAYLOAM103 ........ Low Ambient Kit ........................................................................................................... ✔ — ✔
BAYSEAC001 ........ Seacoast Kit ................................................................................................................. ✔ ✔ ✔
TAYASCT501A12 . Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section


1 Not for use with programmable thermostats
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SC-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1½ through 5 Tons

Table SC-5-A — XR12 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TTR2018A1000A 200-230/1/60 18,000 .049 33 33 30 215 77 10 15 /2 /4
5 5
4TTR2024A1000A 200-230/1/60 24,000 .053 33 33 30 219 78 13 20 /8 /16

PHASED OUT
3 5
4TTR2030A1000A 208-230/1/60 30,000 .059 33 33 30 218 74 20 30 /4 /16
3 3
4TTR2036A1000A 208-230/1/60 36,000 .065 33 33 30 231 77 21 35 /4 /8
3 3
4TTR2042A1000A 208-230/1/60 42,000 .071 37 33 30 243 78 25 40 /4 /8
7 3
XR12 4TTR2048A1000A 208-230/1/60 48,000 .077 41 33 30 260 79 31 50 /8 /8
4TTR2060A1000A 208-230/1/60 60,000 1 33 37 34 283 81 36 60 7
/8 3
/8

Table SC-5-B — XR12 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTR2018A1000A 200-230/1/60 18,000 .051 26 29 26 171 79 10 15 /8 /4
3 5
2TTR2024A1000A 200-230/1/60 24,000 .057 29 29 26 187 78 11 15 /4 /16
3 5
2TTR2030A1000A 208-230/1/60 30,000 .065 29 29 26 180 79 18 30 /4 /16

XR12
PHASED OUT
2TTR2036A1000A
2TTR2042B1000A
2TTR2048A1000A
2TTR2060B1000A
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
36,000
42,000
48,000
60,000
.071
.077
.086
1
33
33
37
41
29
33
33
37
26
30
30
34
195
228
247
270
79
79
78
79
21
23
26
33
35
40
45
50
7

7
/8
/8
1 1/8
1 1/8
3

3
/8
/8
/8
/8

Table SC-5-C — XR11 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTR1018A1000A 200-230/1/60 18,000 .049 26 20 19 129 82 10 15 /8 /4
3 5
2TTR1024A1000A 200-230/1/60 24,000 .057 26 20 19 141 81 13 20 /4 /16
3 5
2TTR1030A1000A 200-230/1/60 30,000 .065 26 29 26 168 79 17 30 /4 /16

PHASED OUT
7 3
2TTR1036A1000A 200-230/1/60 36,000 .073 26 29 26 177 77 22 35 /8 /8
7 3
2TTR1042A1000A 200-230/1/60 42,000 .075 29 29 26 212 79 24 40 /8 /8
2TTR1048A1000A 200-230/1/60 48,000 .083 29 29 26 219 79 29 50 11/8 3
/8
XR11 2TTR1060A1000A 200-230/1/60 60,000 1 37 33 30 269 79 36 60 11/8 3
/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SC-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1½ through 5 Tons

XR 12 XR 12 XR 11
Table SC-6-A — Features (4TTR2) (2TTR2) (2TTR1)

T
• SEER’s up to .......................................................................................................................................................................... 13 13 11.5

OU
• Climatuff™ compressor ........................................................................................................................................................ ✔ ✔ ✔
• Comfort”R”™ mode approved .............................................................................................................................................. ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof .............................................................................................................. ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ....................................................... ✔ ✔ ✔

ED
• Spine Fin™ coil ..................................................................................................................................................................... ✔ ✔ ✔
• Factory installed start kit ......................................................................................................................................................... 1-2 & 5 1-2 —
• Factory supplied charge ......................................................................................................................................................... R-410A R-22 R-22

AS
• Glossy corrosion resistant finish ............................................................................................................................................. ✔ ✔ ✔
• High pressure switch .............................................................................................................................................................. — ✔ ✔
• Internal high / low pressure & temperature protection ............................................................................................................. ✔ ✔ ✔

PH
• Liquid line filter drier - factory installed .................................................................................................................................... ✔ ✔ ✔
• Tarpaulin gray cabinet ............................................................................................................................................................ ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) .......................................................... ✔ ✔ ✔
• Extended warranties available ............................................................................................................................................ ✔ ✔ ✔

Table SC-6-B — Optional Accessories


AY28X079 ............... Evap. Defrost Control Kit .......................................................................................................................... ✔ ✔ ✔

T
BAY24X045 ............. ID Fan Delay Relay Kit ............................................................................................................................. ✔ ✔ ✔
BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ................................................................................ 1½-2 1½-2 1½-5

OU
BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ............................................................................................. 2½-5 2½-5 —
BAYECMT001 ......... Extreme Condition Mounting Kit ............................................................................................................... ✔ ✔ ✔
BAYISLT101 ............ Rubber Isolators ....................................................................................................................................... ✔ ✔ ✔
BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ..................................................................................................... — — 2½-5

ED
BAYKSKT260 .......... Start Kit (Scroll Compressors) .................................................................................................................. 2½-4 2½-5 —
BAYKSKT261 .......... Start Kit (Base 1 & 2TTR1018, 024 only) (Reciprocating Compressors) ................................................... — — 1½-2
BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ............................................................................................. ✔ ✔ ✔

AS
BAYLEGS003 .......... 4" Extension (Black) ................................................................................................................................. ✔ ✔ ✔
BAYLOAM103 ......... Low Ambient Kit ....................................................................................................................................... — ✔ 2½-5
BAYLOAM104 ......... Low Ambient Kit with Start Kit .................................................................................................................. — — 1½-2

PH
BAYSDEN001 ......... Single Cylinder Compressor Enclosures .................................................................................................. — — 1½-2
BAYSDEN003 ......... Small Scroll Compressor Enclosures ........................................................................................................ — 2½-4 —
BAYSEAC001 ......... Seacoast Kit ............................................................................................................................................. ✔ ✔ ✔

Table SC-6-C — Comfort Controls


TAYASCT501A56 .. Anti-Short Cycle Timer ............................................................................................................................. ✔ ✔ ✔
TAYSENS100A3 .... Outdoor Temp. Sensor (with case) ........................................................................................................... ✔ ✔ ✔
TAYSTAT241 .......... Manual 2 Htg/1 Clg ................................................................................................................................... ✔ ✔ ✔
TAYSTAT250B ........
TAYSTAT300C ........
Outdoor Thermostat .................................................................................................................................
XT300C Prog., 7 Day, A/M,1Htg/1Clg ......................................................................................................

✔ T




OU
TAYSTAT302C ........ XT302C Prog., 7 Day, A/M,2Htg/2Clg ...................................................................................................... ✔ ✔ ✔
TAYSTAT340 .......... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ......................................................................................................... ✔ ✔ ✔
TAYSTAT350 .......... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1Clg ................................................................................................ ✔ ✔ ✔
TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ................................................................................................ ✔ ✔ ✔
ED

TAYSTAT3712 ....... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) .............................................................................................. ✔ ✔ ✔


TAYSTAT375 .......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable ............................................................... ✔ ✔ ✔
TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ................................................................................................ ✔ ✔ ✔
AS

TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ........................................................................................................ ✔ ✔ ✔


TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔
TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔
PH

TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔


TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔
TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔
TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) ................................................................................................................... ✔ ✔ ✔
TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ..................................................................................... ✔ ✔ ✔
1 Requires Subbase.
2 Specifically designed for electric heat applications (instant on fan)
3 Used with TAYSTAT300C, TAYSTAT302C
4 Use with BAY28X182, BAY28X183
5 Not for use with programmable thermostats
6 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SC-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1 through 5 Tons

Table SC-7-A — XB13 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTB3018A1000A 200-230/1/60 17,000 TXV-NB 26 29 26 182 76 8 15 /8 /4
3 5
2TTB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 195 78 12 20 /4 /16
3
2TTB3030A1000A 200-230/1/60 28,500 TXV-NB 33 33 30 225 78 13 20 /4 5/16
7 3
2TTB3036A1000A 208-230/1/60 34,500 TXV-NB 33 33 30 220 76 18 30 /8 /8
7 3
2TTB3042A1000A 200-230/1/60 40,500 TXV-NB 33 37 34 283 79 21 35 /8 /8
XB13 2TTB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 307 79 25 40 1 1/8 3/8
2TTB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 303 79 32 50 1 1/8 3/8

Table SC-7-B — XB12 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TTB2018A1000A 200-230/1/60 18,000 .051 26 29 26 172 81 10 15 /8 /4
3 5
2TTB2024A1000A 200-230/1/60 24,000 .057 29 29 26 188 82 11 15 /4 /16
3 5
2TTB2030A1000A 208-230/1/60 30,000 .065 29 29 26 180 79 18 30 /4 /16

XB12
PHASED OUT
2TTB2036A1000A
2TTB2042A1000A
2TTB2048A1000A
2TTB2060A1000A
208-230/1/60
208-230/1/60
208-230/1/60
208-230/1/60
36,000
42,000
48,000
60,000
.071
.077
.086
1
33
33
37
37
29
33
33
33
26
30
30
30
195
216
248
271
79
N/A
78
79
21
23
26
38
35
40
45
60
7

7
/8
/8
11/8
11/8
3

3
/8
/8
/8
/8

Table SC-7-C — XB10 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TTB0030A1000A 200-230/1/60 30,000 .065 26 29 26 169 81 17 30 /4 /16

PHASED OUT
7 3
2TTB0036A1000A 200-230/1/60 36,000 .071 26 29 26 175 80 20 35 /8 /8
7 3
2TTB0042A1000A 200-230/1/60 42,000 .075 26 29 26 208 81 23 40 /8 /8
2TTB0048A1000A 200-230/1/60 48,000 .080 26 29 26 218 82 26 45 11/8 3
/8
2TTB0060A1000A 200-230/1/60 60,000 1 33 33 30 256 83 35 60 11/8 3
/8

XB10

Table SC-7-D — XB10 Split System Cooling — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
TTB012C100A 200-230/1/60 12,000 .049 24 18 18 118 82 11 15 /8 /4
TTB018C100A
TTB024C100A PHASED OUT
200-230/1/60 18,000
208-230/1/60 24,000
1 Indoor Metering device TXV only.
.049
.057
24
24
18
18
18
18
118
130
82
80
11
15
15
25
5

3
/8
/4 5
1

/16
/4

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

XB10

For complete equipment / combination


selections and installation instructions, please SC-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Single Phase – 1 through 5 Tons

XB 13 XB 12 XB 10 XB 10
Table SC-8-A — Features (2TTB3) (2TTB2) (2TTB0) (TTB)

T
• SEER’s up to ..................................................................................................................................................... 13.25 12.50 10.50 10.50

OU
• Climatuff™ compressor ................................................................................................................................... ✔ ✔ ✔ ✔
• Comfort”R”™ mode approved ......................................................................................................................... ✔ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ......................................................................................... ✔ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................. ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔

ED
• Spine Fin™ coil ................................................................................................................................................
• Compressor sump heat - factory installed .......................................................................................................... 5 — — —
• Factory supplied charge .................................................................................................................................... R-22 R-22 R-22 R-22
✔ ✔ ✔ ✔

AS
• Glossy corrosion resistant finish ........................................................................................................................
• Internal high / low pressure & temperature protection ........................................................................................ ✔ ✔ ✔ ✔
• Liquid line filter drier - factory installed ............................................................................................................... ✔ ✔ ✔ ✔
• Polyslate gray cabinet ....................................................................................................................................... ✔ ✔ ✔ ✔

PH
• Quick start kit - factory installed ......................................................................................................................... 1½-2½,3½-5 1½-2 — —
• 5 year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔ ✔
• Extended warranties available ....................................................................................................................... ✔ ✔ ✔ ✔
Table SC-8-B — Optional Accessories
AY28X079 ............... Evap. Defrost Control Kit ..................................................................................................... ✔ ✔ ✔ ✔
BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ........................................................... 1½-2½,3½-4 1½-2 2½-5 1-2

T
BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ........................................................................ 3 2½-5 — —
BAYECMT001 ......... Extreme Condition Mounting Kit .......................................................................................... ✔ ✔ ✔ —

OU
BAYISLT100 ............ Rubber Isolators (012, 018 & 024 only) ............................................................................... — — — ✔
BAYISLT101 ............ Rubber Isolators .................................................................................................................. ✔ ✔ ✔ —
BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ................................................................................ — — 2½-5 —
BAYKSKT260 .......... Start Kit (Scroll Compressors) ............................................................................................. 3 2½-5 — —

ED
BAYKSKT261 .......... Start Kit (18" only - TTB012,018 & 024) (Reciprocating Compressors) ................................ — — — 1-2
BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ........................................................................ ✔ ✔ ✔ —
BAYLEGS003 .......... 4" Extension (Black) ............................................................................................................ ✔ ✔ ✔ —

AS
BAYLOAM103 ......... Low Ambient Kit .................................................................................................................. ✔ ✔ ✔ —
BAYLOAM104 ......... Low Ambient Control Kit ...................................................................................................... — — — ✔
BAYSDEN001 ......... Single Cylinder Compressor Enclosures ............................................................................. 1½-2½ 1½-2 2½-3 1-2

PH
BAYSDEN002 ......... Two Cylinder Compressor Enclosures ................................................................................. — — 3½-5 —
BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................... 3 2½-4 — —
BAYSDEN004 ......... Large Scroll Compressor Enclosures .................................................................................. 5 5 — —
BAYSEAC001 ......... Seacoast Kit ........................................................................................................................ ✔ ✔ ✔ —
Table SC-8-C — Comfort Controls
AY28X092 ............... Heat/Cool ( Horiz.) Therm. .................................................................................................. ✔ ✔ ✔
BAYSTAT304 .......... Cooling Only w/ Fan Switch ................................................................................................. ✔ ✔ ✔
BAYSTAT305 .......... Heat/Cool ( Vertical ) Therm. ............................................................................................... ✔


✔T ✔

OU
TAYASCT501A56 .. Anti-Short Cycle Timer ........................................................................................................
Zone Sensors Section

✔ ✔ ✔
See Comfort Controls/

TAYSENS100A3 .... Outdoor Temp. Sensor (with case) ......................................................................................


TAYSTAT250B ........ Outdoor Thermostat ............................................................................................................ ✔ ✔ ✔
TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg .......................................................................... ✔ ✔ ✔
✔ ✔ ✔
ED

TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ...........................................................................


TAYSTAT3712 ....... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) ......................................................................... ✔ ✔ ✔
TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ................................................................................... ✔ ✔ ✔
TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔
AS

TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔


TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔
TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔
PH

TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔


TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) .............................................................................................. ✔ ✔ ✔
TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ................................................................ ✔ ✔ ✔
1 Requires Subbase.
2 Specifically designed for electric heat applications (instant on fan)
3 Used with TAYSTAT300C, TAYSTAT302C
4 Use with BAY28X182, BAY28X183
5 Not for use with programmable thermostats
6 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SC-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 2½ through 6 Tons

Table SC-9-A — 2TTA0 Split System Cooling — Three Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3
2TTA0030A3000A 200-230/3/60 30,000 .065 26 29 26 175 80 13 20 /4 5/16
7 3
2TTA0036A3000A 200-230/3/60 36,000 .073 26 29 26 179 79 15 25 /8 /8
7 3
2TTA0042A3000A 200-230/3/60 42,000 .075 29 29 26 211 83 18 30 /8 /8
2TTA0048A3000A 200-230/3/60 48,000 .083 29 29 26 216 82 20 30 11/8 3/8
2TTA0060A3000A 200-230/3/60 60,000 1 33 33 30 255 82 27 45 11/8 3/8
2TTA0072A3000A 200-230/3/60 72,000 1 41 37 34 297 81 26 45 11/8 3/8
2TTA0
3
2TTA0030A4000A 460/3/60 30,000 .065 26 29 26 175 80 7 15 /4 5/16
7 3
2TTA0036A4000A 460/3/60 36,000 .073 26 29 26 179 79 8 15 /8 /8
7 3
2TTA0042A4000A 460/3/60 42,000 .075 29 29 26 211 83 9 15 /8 /8
2TTA0048A4000A 460/3/60 48,000 .083 29 29 26 216 82 10 15 11/8 3/8
2TTA0060A4000A 460/3/60 60,000 1 33 33 30 255 82 13 20 11/8 3/8
2TTA0072A4000A 460/3/60 72,000 1 41 37 34 297 81 14 20 11/8 3/8

Table SC-9-B — 2TTA3 Split System Cooling — Three Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3
2TTA3030A3000A 200-230/3/60 30,000 TXV-NB 33 33 30 225 78 9 15 /4 5/16
7 3
2TTA3036A3000A 200-230/3/60 36,000 TXV-NB 33 33 30 216 76 13 20 /8 /8
7 3
2TTA3042A3000A 200-230/3/60 42,000 TXV-NB 33 37 34 245 79 13 20 /8 /8
2TTA3048A3000A 200-230/3/60 48,000 TXV-NB 41 37 34 303 79 16 25 1 1/8 3/8
2TTA3060A3000A 200-230/3/60 60,000 TXV-NB 41 37 34 292 79 23 40 1 1/8 3/8

3
2TTA3 2TTA3030A4000A 460/3/60 30,000 TXV-NB 33 33 30 225 78 5 15 /4 5/16
7 3
2TTA3036A4000A 460/3/60 36,000 TXV-NB 33 33 30 219 76 7 15 /8 /8
7 3
2TTA3042A4000A 460/3/60 42,000 TXV-NB 33 37 34 246 79 7 15 /8 /8
2TTA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 305 79 9 15 1 1/8 3/8
2TTA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 293 79 10 15 1 1/8 3/8

Table SC-9-C — 2TTA2 Split System Cooling — Three Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3
2TTA2030A3000A 200-230/3/60 30,000 .065 29 29 26 177 79 12 20 /4 5/16
7 3
2TTA2036A3000A 200-230/3/60 36,000 .071 33 29 26 192 79 15 25 /8 /8
7 3
2TTA2042B3000A 200-230/3/60 42,000 .077 33 33 30 212 79 17 25 /8 /8
2TTA2048A3000A 200-230/3/60 48,000 .086 37 33 30 242 78 20 35 11/8 3/8
2TTA2060A3000A 200-230/3/60 60,000 1 37 33 30 258 79 24 40 11/8 3/8

2TTA2
PHASED OUT
2TTA2030A4000A
2TTA2036A4000A
2TTA2042B4000A
2TTA2048A4000A
460/3/60
460/3/60
460/3/60
460/3/60
30,000
36,000
42,000
48,000
.065
.071
.077
.086
29
33
33
37
29
29
33
33
26
26
30
30
180
191
212
241
79
79
79
78
6
8
8
10
15
15
15
15
3

7
/4 5/16
/8
/8
3

3
/8
/8
11/8 3/8
2TTA2060A4000A 460/3/60 60,000 1 37 33 30 258 79 12 20 11/8 3/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SC-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 2½ through 6 Tons

Table SC-10-A — Features 2TTA0 2TTA3 2TTA2

PHASED OUT
• SEER's up to .................................................................................................................................................................. 11.75 14.50 12.50
• Climatuff™ compressor ................................................................................................................................................ ✔ ✔ ✔
• Comfort”R”™ mode approved ...................................................................................................................................... ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ............................................... ✔ ✔ ✔
• Spine Fin™ coil ............................................................................................................................................................. ✔ ✔ ✔
• Compressor sump heat - factory installed ....................................................................................................................... 2½-6 2½-5 2½-5
• Factory supplied charge ................................................................................................................................................. R-22 R-22 R-22
• Glossy corrosion resistant finish ..................................................................................................................................... ✔ ✔ ✔
• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔
• Low pressure switch ....................................................................................................................................................... ✔ ✔ —
• PolySlate gray cabinet .................................................................................................................................................... ✔ ✔ ✔
• 5-year limited warranty on compressor, and 1 year on coil and parts (Commercial) ....................................................... ✔ ✔ ✔
• 5-year limited warranty on compressor, coil and 1 year on parts (Residential) ................................................................ ✔ ✔ ✔
• Extended warranties available .................................................................................................................................... ✔ ✔ ✔

Table SC-10-B — Optional Accessoriess

PHASED OUT
AY28X079 .................................... Evaporator Defrost Control .......................................................................................... ✔ ✔ ✔
BAYECMT001 .............................. Extreme Condition Mounting Kit ................................................................................... ✔ ✔ ✔
BAYISLT101 ................................. Rubber Isolators ........................................................................................................... ✔ ✔ ✔
BAYLEGS002 ............................... Snow Legs - Base and Cap 6" High (Black) ................................................................. ✔ ✔ ✔
BAYLEGS003 ............................... 4" Extension (Black) ..................................................................................................... ✔ ✔ ✔
BAYLOAM103 .............................. Electronic Head Pressure Control ................................................................................ ✔ ✔ ✔
BAYSDEN001 .............................. Single Cylinder Compressor Enclosures ...................................................................... 2½-3 2½ —
BAYSDEN002 .............................. Two Cylinder Compressor Enclosures ......................................................................... 3½-5 3½-4 —
BAYSDEN003 .............................. Small Scroll Compressor Enclosures ........................................................................... — 3 2½-4
BAYSDEN004 .............................. Large Scroll Compressor Enclosures ........................................................................... 6 5 5
BAYSEAC001 .............................. Seacoast Kit ................................................................................................................. ✔ ✔ ✔
TAYASCT501A12 ...................... Anti-Short Cycle Timer ................................................................................................. ✔ ✔ ✔

Table SC-10-C — Comfort Controls


TAYSENS100A ........................... Outdoor Temp. Sensor (with case) .............................................................................. ✔

PHASED OUT
TAYSTAT241 ............................... Manual 2 Stg Htg/1 Clg ................................................................................................ ✔
TAYSTAT250B ............................. Outdoor Thermostat ..................................................................................................... ✔
TAYSTAT300C ............................ XT300C Prog.,7 Day,A/M,1Htg/1Clg ............................................................................ ✔
Zone Sensors Section

Zone Sensors Section


See Comfort Controls/

See Comfort Controls/


TAYSTAT340 ............................... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ............................................................................. ✔
TAYSTAT350 ............................... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1 Clg ................................................................... ✔
TAYSTAT370 ............................... Electronic, 1Htg(Gas)/1Clg(Non Prog.) ........................................................................ ✔
TAYSTAT371 ............................... Electronic, 1Htg(Elec)/1Clg(Non Prog.) ........................................................................ ✔
TAYSTAT380 ............................... Electronic, 2 Htg (Gas) 1 Clg(Non Prog.) ..................................................................... ✔
TCONT200A ................................. Electronic, 1Htg/1Clg (Gas/Elec./Oil) ........................................................................... ✔
TCONT401A ................................. 2Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔
TCONT402A ................................. 3Heat/2Clg (Heat Pump/A/C) ....................................................................................... ✔
TCONT600A ................................. 1Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔
TCONT602A ................................. 2Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔
TCONT800A ................................. 2Heat/1Clg (Heat Pump/A/C) ....................................................................................... ✔
TCONT802A ................................. 3Heat/2Clg (Heat Pump/A/C) ....................................................................................... ✔
TCONT803A ................................. 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ........................................................ ✔
1 Do not use with programmable thermostats.
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SC-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 7½ through 20 Tons

• New ReliaTel™ controls option • Internal pressure relief valves


• (1) Trane 3-D® Scroll compressor (TTA090- (TTA120B,120C,150B)
120A) • Holding charge of Nitrogen
• (2) Trane Scroll compressors (TTA120- • Copper tube, aluminum plate fin coils
240B) with independent refrigerant circuits • Low ambient cooling to 50°F as shipped.
• (2) Manifolded Scroll compressors with • Low ambient cooling to 0°F with accessory
unloading capability (TTA120 & 180C) head pressure control
• Single point power supply • Mounting/lifting rails under base
• Compressor motor overload protection • UL listed
TTA – 7½ through 20 Tons • Control transformer • 5 year compressor warranty
• High and low pressure cut-out switches (TTA090-120A/TTA120-180B/TTA120-180C)
• Liquid line filter drier, factory installed • 1 year compressor warranty (TTA240B)
• Service valves with pressure taps • 1 year limited parts warranty
• Optional Extended Warranties

Table SC-11-A — TTA Split System Cooling — Single Compressor


Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.
TTA090A300F — 208/230/3/60 92,000 39 34 41 SPR 370 8.8 34.5 50 13/8 1
/2
TTA090A30SF Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370
TTA090A30RF ReliaTel™, No LCI Board 208-230/3/60 92,000 39 34 41 SPR 370
TTA090A30TF ReliaTel™, No LCI Board W/Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370
TTA090A30UF ReliaTel™, W/LCI Board 208-230/3/60 92,000 39 34 41 SPR 370
TTA090A30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 92,000 39 34 41 SPR 370

TTA120A300F — 208/230/3/60 128,000 39 38 51 SPR 443 8.8 48.1 70 13/8 1


/2
TTA120A30SF Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443
TTA120A30RF ReliaTel™, No LCI Board 208-230/3/60 128,000 39 38 51 SPR 443
TTA120A30TF ReliaTel™, No LCI Board W/Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443
TTA120A30UF ReliaTel™, W/LCI Board 208-230/3/60 128,000 39 38 51 SPR 443
TTA120A30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 128,000 39 38 51 SPR 443

TTA090A400F — 460/3/60 92,000 39 34 41 SPR 370 8.8 18.1 25 13/8 1


/2
TTA090A40SF Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370
TTA090A40RF ReliaTel™, No LCI Board 460/3/60 92,000 39 34 41 SPR 370
TTA090A40TF ReliaTel™, No LCI Board W/Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370
TTA090A40UF ReliaTel™, W/LCI Board 460/3/60 92,000 39 34 41 SPR 370
TTA090A40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 92,000 39 34 41 SPR 370

TTA120A400F — 460/3/60 128,000 39 38 51 SPR 443 8.8 23.3 35 13/8 1


/2
TTA120A40SF Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443
TTA120A40RF ReliaTel™, No LCI Board 460/3/60 128,000 39 38 51 SPR 443
TTA120A40TF ReliaTel™, No LCI Board W/Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443
TTA120A40UF ReliaTel™, W/LCI Board 460/3/60 128,000 39 38 51 SPR 443
TTA120A40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 128,000 39 38 51 SPR 443

TTA090AW00F — 575/3/60 92,000 39 34 41 SPR 370 8.8 14.5 20 13/8 1


/2
TTA090AW0SF Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370
TTA090AW0RF ReliaTel™, No LCI Board 575/3/60 92,000 39 34 41 SPR 370
TTA090AW0TF ReliaTel™, No LCI Board W/Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370
TTA090AW0UF ReliaTel™, W/LCI Board 575/3/60 92,000 39 34 41 SPR 370
TTA090AW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 92,000 39 34 41 SPR 370

TTA120AW00F — 575/3/60 128,000 39 38 51 SPR 443 8.8 18.8 25 13/8 1


/2
TTA120AW0SF Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443
TTA120AW0RF ReliaTel™, No LCI Board 575/3/60 128,000 39 38 51 SPR 443
TTA120AW0TF ReliaTel™, No LCI Board W/Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443
TTA120AW0UF ReliaTel™, W/LCI Board 575/3/60 128,000 39 38 51 SPR 443
TTA120AW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 128,000 39 38 51 SPR 443
1 Sound rated in accordance with A.R.I. Standard 270.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please SC-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 10 through 20 Tons

Table SC-12-A — TTA Split System Cooling — Dual Compressor


Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.
TTA120B300E — 208-230/3/60 126,000 39 38 51 SPR 481 8.8 47.9 60 11/8 3
/8
TTA120B30SE Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481
TTA120B30RE ReliaTel™, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 481
TTA120B30TE ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481
TTA120B30UE ReliaTel™, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 481
TTA120B30WE ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 481

TTA150B300E — 208/230/3/60 148,000 39 38 51 SPR 481 8.8 55.5 70 11/8 3


/8
TTA150B30SE Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481
TTA150B30RE ReliaTel™, No LCI Board 208-230/3/60 148,000 39 38 51 SPR 481
TTA150B30TE ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481
TTA150B30UE ReliaTel™, W/LCI Board 208-230/3/60 148,000 39 38 51 SPR 481
TTA150B30WE ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 148,000 39 38 51 SPR 481

TTA180B300F — 208/230/3/60 182,000 39 34 88 SPR 764 8.8 62.7 80 13/8 1


/2
TTA180B30SF Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764
TTA180B30RF ReliaTel™, No LCI Board 208-230/3/60 182,000 39 34 88 SPR 764
TTA180B30TF ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764
TTA180B30UF ReliaTel™, W/LCI Board 208-230/3/60 182,000 39 34 88 SPR 764
TTA180B30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764

TTA240B300F — 208/230/3/60 246,000 45 44 94 SPR 915 8.8 87.8 100 13/8 1


/2
TTA240B30SF Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948
TTA240B30RF ReliaTel™, No LCI Board 208-230/3/60 246,000 45 44 94 SPR 948
TTA240B30TF ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948
TTA240B30UF ReliaTel™, W/LCI Board 208-230/3/60 246,000 45 44 94 SPR 948
TTA240B30WF ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 246,000 45 44 94 SPR 948

TTA120B400E — 460/3/60 126,000 39 38 51 SPR 481 8.8 23.9 30 11/8 3


/8
TTA120B40SE Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481
TTA120B40RE ReliaTel™, No LCI Board 460/3/60 126,000 39 38 51 SPR 481
TTA120B40TE ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481
TTA120B40UE ReliaTel™, W/LCI Board 460/3/60 126,000 39 38 51 SPR 481
TTA120B40WE ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 126,000 39 38 51 SPR 481

TTA150B400E — 460/3/60 148,000 39 38 51 SPR 481 8.8 28.1 35 11/8 3


/8
TTA150B40SE Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481
TTA150B40RE ReliaTel™, No LCI Board 460/3/60 148,000 39 38 51 SPR 481
TTA150B40TE ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481
TTA150B40UE ReliaTel™, W/LCI Board 460/3/60 148,000 39 38 51 SPR 481
TTA150B40WE ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 148,000 39 38 51 SPR 481

TTA180B400F — 460/3/60 182,000 39 34 88 SPR 764 8.8 32.9 45 13/8 1


/2
TTA180B40SF Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764
TTA180B40RF ReliaTel™, No LCI Board 460/3/60 182,000 39 34 88 SPR 764
TTA180B40TF ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764
TTA180B40UF ReliaTel™, W/LCI Board 460/3/60 182,000 39 34 88 SPR 764
TTA180B40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764

TTA240B400F — 460/3/60 246,000 45 44 94 SPR 915 8.8 42.5 50 13/8 1


/2
TTA240B40SF Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915
TTA240B40RF ReliaTel™, No LCI Board 460/3/60 246,000 45 44 94 SPR 915
TTA240B40TF ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915
TTA240B40UF ReliaTel™, W/LCI Board 460/3/60 246,000 45 44 94 SPR 915
TTA240B40WF ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 246,000 45 44 94 SPR 915
1 Sound rated in accordance with A.R.I. Standard 270.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 SC-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 10 through 20 Tons

Table SC-13-A — TTA Split System Cooling — Dual Compressor (continued)


Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.
TTA120BW00E — 575/3/60 126,000 39 38 51 SPR 481 8.8 19.1 25 11/8 3
/8
TTA120BW0SE Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481
TTA120BW0RE ReliaTel™, No LCI Board 575/3/60 126,000 39 38 51 SPR 481
TTA120BW0TE ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481
TTA120BW0UE ReliaTel™, W/LCI Board 575/3/60 126,000 39 38 51 SPR 481
TTA120BW0WE ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 126,000 39 38 51 SPR 481

TTA150BW00E — 575/3/60 148,000 39 38 51 SPR 481 8.8 21.6 25 11/8 3


/8
TTA150BW0SE Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481
TTA150BW0RE ReliaTel™, No LCI Board 575/3/60 148,000 39 38 51 SPR 481
TTA150BW0TE ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481
TTA150BW0UE ReliaTel™, W/LCI Board 575/3/60 148,000 39 38 51 SPR 481
TTA150BW0WE ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 148,000 39 38 51 SPR 481

TTA180BW00F — 575/3/60 182,000 39 34 88 SPR 764 8.8 26.3 35 13/8 1


/2
TTA180BW0SF Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764
TTA180BW0RF ReliaTel™, No LCI Board 575/3/60 182,000 39 34 88 SPR 764
TTA180BW0TF ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764
TTA180BW0UF ReliaTel™, W/LCI Board 575/3/60 182,000 39 34 88 SPR 764
TTA180BW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764

TTA240BW00F — 575/3/60 246,000 45 44 94 SPR 915 8.8 34.2 45 13/8 1


/2
TTA240BW0SF Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915
TTA240BW0RF ReliaTel™, No LCI Board 575/3/60 246,000 45 44 94 SPR 915
TTA240BW0TF ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915
TTA240BW0UF ReliaTel™, W/LCI Board 575/3/60 246,000 45 44 94 SPR 915
TTA240BW0WF ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 246,000 45 44 94 SPR 915
1 Sound rated in accordance with A.R.I. Standard 270.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please SC-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 10 through 15 Tons

Table SC-14-A — TTA Split System Cooling — Dual Manifolded Compressors with Single Refrigerant Circuits
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound1 Max. OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA* Fuse* Gas Liq.
TTA120C300G — 208-230/3/60 126,000 39 38 51 SPR 492 8.8 49.4 60 13/8 1
/2
TTA120C30SG Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30RG ReliaTel™, No LCI Board 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30TG ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30UG ReliaTel™, W/LCI Board 208-230/3/60 126,000 39 38 51 SPR 492
TTA120C30WG ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 126,000 39 38 51 SPR 492

TTA180C300G — 208-230/3/60 182,000 39 34 88 SPR 764 8.8 62.7 80 15/8 5


/8
TTA180C30SG Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764
TTA180C30RG ReliaTel™, No LCI Board 208-230/3/60 182,000 39 34 88 SPR 764
TTA180C30TG ReliaTel™, No LCI Board w/Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764
TTA180C30UG ReliaTel™, W/LCI Board 208-230/3/60 182,000 39 34 88 SPR 764
TTA180C30WG ReliaTel™, W/LCI Board & Epoxy Coil 208-230/3/60 182,000 39 34 88 SPR 764v

TTA120C400G — 460/3/60 126,000 39 38 51 SPR 492 8.8 25.2 30 13/8 1


/2
TTA120C40SG Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492
TTA120C40RG ReliaTel™, No LCI Board 460/3/60 126,000 39 38 51 SPR 492
TTA120C40TG ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492
TTA120C40UG ReliaTel™, W/LCI Board 460/3/60 126,000 39 38 51 SPR 492
TTA120C40WG ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 126,000 39 38 51 SPR 492

TTA180C400G — 460/3/60 182,000 39 34 88 SPR 764 8.8 32.9 45 15/8 5


/8
TTA180C40SG Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764
TTA180C40RG ReliaTel™, No LCI Board 460/3/60 182,000 39 34 88 SPR 764
TTA180C40TG ReliaTel™, No LCI Board w/Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764
TTA180C40UG ReliaTel™, W/LCI Board 460/3/60 182,000 39 34 88 SPR 764
TTA180C40WG ReliaTel™, W/LCI Board & Epoxy Coil 460/3/60 182,000 39 34 88 SPR 764

TTA120CW00G — 575/3/60 126,000 39 38 51 SPR 492 8.8 19.8 25 13/8 1


/2
TTA120CW0SG Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492
TTA120CW0RG ReliaTel™, No LCI Board 575/3/60 126,000 39 38 51 SPR 492
TTA120CW0TG ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492
TTA120CW0UG ReliaTel™, W/LCI Board 575/3/60 126,000 39 38 51 SPR 492
TTA120CW0WG ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 126,000 39 38 51 SPR 492

TTA180CW00G — 575/3/60 182,000 39 34 88 SPR 764 8.8 26.3 35 15/8 5


/8
TTA180CW0SG Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764
TTA180CW0RG ReliaTel™, No LCI Board 575/3/60 182,000 39 34 88 SPR 764
TTA180CW0TG ReliaTel™, No LCI Board w/Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764
TTA180CW0UG ReliaTel™, W/LCI Board 575/3/60 182,000 39 34 88 SPR 764
TTA180CW0WG ReliaTel™, W/LCI Board & Epoxy Coil 575/3/60 182,000 39 34 88 SPR 764
1 Sound rated in accordance with A.R.I. Standard 270.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 SC-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 7½ through 20 Tons

Table SC-15-A — Optional Accessories


Model
Number Description Used With
BAY24X042 ....................... Fan Control Relay .......................................... TTA090-120A, 120-240B, 120-180C
(Outdoor Thermostat 45°F to -10°F)
BAYASCT00139 ............. Anti-Short-Cycle Timer ................................... TTA090-120A, 120-240B, 120-180C
BAYGARD024A ................ Coil Guard Kit ................................................. TTA090A
BAYGARD026A ................ Coil Guard Kit ................................................. TTA150B, TTA120A, B, C
BAYGARD039A ................ Coil Guard Kit ................................................. TTA180B, C
BAYGARD042A ................ Coil Guard Kit ................................................. TTA240B
BAYHGBP002C1 ............. Hot Gas Bypass Kit ........................................ TTA090-120A
BAYHGBP003C12 .......... Hot Gas Bypass Kit ........................................ TTA180B, C, TTA240B, TTA120B, C; TTA150B
BAYISLT004A ................... Rubber-In-Shear Isolators .............................. TTA090A
BAYISLT005A ................... Rubber-In-Shear Isolators .............................. TTA120A, B, C
BAYISLT009A ................... Rubber-In-Shear Isolators .............................. TTA150-180B, TTA180C
BAYISLT010A ................... Rubber-In-Shear Isolators .............................. TTA240B
BAYISLT023A ................... Steel Spring Isolators ..................................... TTA090-120A, 120C
BAYISLT024A ................... Steel Spring Isolators ..................................... TTA180B, TTA180C, TTA120-150B
BAYISLT025A ................... Steel Spring Isolators ..................................... TTA240B
BAYLOAM015A0 .............. Head Pressure Control – 575V ...................... TTA090-180AW, BW, CW
BAYLOAM326A40 ........... Head Pressure Control – 230V ...................... TTA090A3
BAYLOAM327A40 ........... Head Pressure Control – 230V ...................... TTA120A3, B3, 120C3, 150B3
BAYLOAM329A240 ....... Head Pressure Control – 230V ...................... TTA180B3, C3
BAYLOAM328A240 ......... Head Pressure Control – 230V ...................... TTA240B3
BAYLOAM425A0 .............. Head Pressure Control – 460V ...................... TTA090A4
BAYLOAM426A40 ........... Head Pressure Control – 460V ...................... TTA120A4, B4, 150B4, 120C4
BAYLOAM428A240 ......... Head Pressure Control – 460V ...................... TTA180B4, C4
BAYLOAM427A240 ......... Head Pressure Control – 460V ...................... TTA240B4
BAYLOAM429Bqw ........... Low Ambient Fan Cycle Control .................... TTA090-240A,B,C
BAYLOAMW22A0 ............. Head Pressure Control – 575V ...................... TTA120, 150, 240AW, BW, CW
BAYRLAY0023 ................ Time Delay Relay ........................................... TTA120-240B, TTA120-180C, TTA090-120A
BAYSTAT033A .................. Outdoor Thermostat 45°F to -10°F ................ TTA090-120A, TTA120-240B, TTA120-180C

Table SC-15-B — Comfort Controls


Model
Number Description Used With
BAY28X1825 .................... 1-Stage Htg/Clg .............................................. TTA090-120A
BAY28X1835 .................... 2-Stage Htg/Clg .............................................. TTA090-120A, 120-240B, 120-180C
BAY28X1865 .................... 2-Stage Clg ..................................................... TTA090-120A, 120-240B, 120-180C
BAY28X1846 .................... Subbase (Automatic/Manual Changeover) ..... BAY28X183
BAY28X1857 .................... Subbase (Manual Changeover) ...................... BAY28X182, 183
BAY28X1876 ..................... Subbase (Automatic Changeover) ................. BAY28X182, 183, 186
BAY28X1903 .................... Locking Thermostat Cover ............................. All Room Thermostats
BAYBASE006A0 ............... Subbase 2-Stage Htg/Clg ............................... BAYSTAT040B with TTA090-120A,120-240B or 120-180C
BAYBASE008A .................. Subbase 1-Stage Htg/Clg ............................... BAYSTAT040B with TTA090-120A
BAYSENS033A .................. Remote Wall Sensor ....................................... BAYSTAT040B
BAYSENS034A0 ............... Duct Temperature Sensor ............................... BAYSTAT040B
BAYSTAT040B80 .............. Programmable Thermostat ............................. BAYBASE006A or BAYBASE008A
TAYSENS100A .................. Outdoor Temp. Sensor (With Case) ............... TAYSTAT300C,302C,375
TAYSTAT300C .................. XT 300C Prog., 7Day, A/M,1Htg/1Clg ............ All Cooling Models
TAYSTAT302C .................. XT 302C Prog., 7Day, A/M,2Htg/2Clg ............ All Cooling Models
TCONT200AN11AA ........... Electronic 1-Stage Htg/Clg ............................. TTA090A,120A
1 Condensing unit must be on same level as or below Air Handler. Contact Application Engineer, Clarksville, before using any other configuration. (See Installers Guide).
2 Quantity: 2 required on TTA180B, C; TTA240B.
3 Do not use with programmable thermostats or ReliaTel™ model.
4 Kits mount to the outdoor unit and operate by sensing liquid.
5 Requires Subbase.
6 Requires BAY24X042 relay kit when used with electric heat.
7 Specifically designed for electric heat applications (instant on fan).
8 Requires BAYBASE006A or BAYBASE008A.
9 Activated on Power On.
0 Option is compatible for units with ReliaTel™ Controls.
q Option is compatible for units with electric mechanical controls only.
w Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures.

For complete equipment / combination


selections and installation instructions, please SC-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Cooling
Three Phase – 7½ through 20 Tons

Table SC-16-A — Sensors for use with ReliaTel™ units.


Model Mfg. Shipping
Number Description Used With Plant Weight
BAYSENS006B Single Setpoint Manual TTA090A_OR, OU, OT, OW- CK/001 1
Changeover Zone Sensor TTA240B_OR, OU, OT, OW
BAYSENS008B Dual Setpoint Manual or Auto TTA090A_OR, OU, OT, OW- CK/001 1
Changeover Zone Sensor TTA240B_OR, OU, OT, OW
BAYSENS010B Dual Setpoint Manual or Auto TTA090A_OR, OU, OT, OW- CK/001 1
Changeover Zone Sensor with TTA240B_OR, OU, OT, OW
System Function Lights
BAYSENS013C Zone Sensor w/ Timed TTA090A_OR, OU, OT, OW- CK/001 1
Override & Cancel TTA240B_OR, OU, OT, OW
BAYSENS014C Zone Sensor w/ Setpoint TTA090A_OR, OU, OT, OW- CK/001 1
Timed Override and Cancel TTA240B_OR, OU, OT, OW
BAYSENS017B Wall Mounted Zone Sensor for TTA090A_OR, OU, OT, OW- CK/001 1
Remote Sensing TTA240B_OR, OU, OT, OW
BAYSENS019C Programmable Zone sensor TTA090A_OR, OU, OT, OW- CK/001 1
NSB Panel TTA240B_OR, OU, OT, OW
BAYSENS032A Remote Wall Sensor TTA090A_OR, OU, OT, OW- CK/001 1
for use with BAYSENS035A TTA240B_OR, OU, OT, OW
BAYSENS033A Remote Wall Sensor TTA090A-TTA240B CK/001 1
for use with BAYSENS040A
BAYSENS034A Remote Duct Sensor TTA090A-TTA240B CK/001 1
for use with BAYSTAT040B
BAYSENS035A Digital Zone Sensor with TTA090A_OR,OU,OT,OW- CK/001 1
LCD Display TTA240B_OR,OU,OT,OW

Table SC-16-B — Controls


BAYICSI003A Trane Communication Interface (TCI) TTA090_OR,OT- CK/001 1
TTA240_OR,OT
BAYLTCI002B LonTalk Communication Interface (LCI) TTA090_OR,OT- CK/001 1
TTA240_OR,OT

For complete equipment / combination


Effective 1/1/06 SC-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
7 ½ - 20 Tons with
ReliaTel™ Controls
TTA090-120, TTA120-240, TTA120-180C
Protection/Operation Timings and Features

Anti Short Cycle Timer (ASCT) Function — Provides a three (3) Low Ambient Start Timer (LAST) Function — Bypasses low
minute minimum “ON” time and a three (3) minute minimum “OFF” time pressure control when a compressor starts, eliminating nuisance
for compressors, enhances compressor reliability by ensuring proper oil compressor lock outs. Standard
return. Standard
Lower Installation Cost — Using a standard Zone Sensor Module
Built In Fan Delay Relay (FDR) Function — Provides custom indoor (ZSM), control voltage wiring may be run up to five (5) times further
fan timing sequences for the different types of equipment, enhancing than any electromechanical system, with no increase in wire gauge.
efficiency and reliability. Standard Example: Electromechanical System –
30 feet maximum using 22 gauge wire. Micro Control System – 150
Built In Night Set Back and Unoccupied Functions1 — When using feet using 22 gauge wire. Standard
a standard dual setpoint/auto change over Zone Sensor Module (ZSM),
this function is enabled by applying a short across terminal J6-11 and On Board Diagnostics1 — Assist with equipment troubleshooting, if
J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint a problem occurrence should take place. Standard
back a minimum of 7°F, and forces fan operation to automatic.
(requires time clock accessory or field supplied/installed switch or Remote Sensing1 — All standard Zone Sensor Modules
contacts). (ZSMs) have remote sensing capabilities, typically achieved by using
an expensive program-mable thermostat and remote sensor with
Built In “TEST” Mode — Aids in quick verification of system electromechanical equipment. Accessory (requires use of remote
and control operation, exercises both hardware and software sensor).
(no special tools required). Standard
Space Temperature Averaging1 — All standard Zone Sensor
Built In Unoccupied Mode1 — When using a standard single Modules (ZSMs) have space temperature averaging capabilities,
setpoint/manual change over Zone Sensor Module (ZSM), this function typically achieved by using an expensive programmable thermostat
is enabled by applying a short across terminal J6-11 and J6-12. Forces and minimum of four (4) remote sensors with electromechanical
fan operation to automatic. (requires time clock accessory or field equipment. Averaging with ReliaTel™ can be achieved with two
supplied/installed switch or contacts.) (2) sensors.
Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Time Delay Relay (TDR) Function — Provides an incremental
Proportional – sets corrective action proportional to deviation staging delay between compressors, minimizes equipment current
from setpoint. Integral – fine tunes the rate of corrective action inrush and consumption by keeping compressors from starting
proportional to the error (results in superior space temperature control). simultaneously. Standard
Standard
Low Pressure and High Pressure Compressor Lockout — 3 trips
Increased Reliability — Fewer components (moving electro- will lockout control.
mechanical parts), less likelihood of equipment down time or
failure. Standard
Integral Electric Heat Staging1 — Stages electric heaters “OFF” and
“ON”, eliminating the use of outdated sequencers. Standard
Intelligent Fallback1 — A built in Default Control provides adaptive
operation, which allows the equipment to continue
to operate, providing comfort in the event of certain component failures.
Also, allows emergency operation without a Zone Sensor Module
(ZSM). Standard

1 Denotes features lost from utilizing standard conventional stat.

For complete equipment / combination


selections and installation instructions, please SC-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
7 ½ - 20 Tons with ReliaTel™
Micro Control
Operation With A Thermostat

When the ReliaTel™ RTRM Thermostat Interface is used, equipment operation


differs significantly. The basic equipment protection features remain intact, and the
following features and benefits are lost:

• Direct Digital Control (DDC) – • Space Temperature Averaging


Proportional Integral (PI) control is lost, capabilities are lost, unless generic
equipment is controlled by a thermostat control being applied can accomplish
or generic building automation system this.
device. • Built In Night Set Back and Unoccu-
• Intelligent Fall back is lost, if a failure pied functions are lost, unless
occurs in the device controlling the generic control being applied can
equipment, operation will cease. accomplish this.
• Installation is more costly, with the • Built In Unoccupied Mode is lost,
addition of a thermostat or generic unless generic control being applied
control, the control wiring size must be can accomplish this.
increased.
• Remote Sensing capabilities are lost,
unless generic control being applied can
accomplish this.

For complete equipment / combination


Effective 1/1/06 SC-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

Table SH-1-A — XL19i Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Uncrated Shipping Line Size
Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.
7 3
2TWZ9030B1000A 200/230/1/60 30,000 TXV-NB 50 37 34 443 74 19 30 /8 /8
7 3
2TWZ9036B1000A 200/230/1/60 36,000 TXV-NB 50 37 34 440 74 22 36 /8 /8
2TWZ9048B1000A 200/230/1/60 48,000 TXV-NB 50 37 34 448 74 25 40 11/8 3
/8
2TWZ9060B1000A 200/230/1/60 60,000 TXV-NB 50 37 34 455 74 37 60 11/8 3
/8
Note: Because of limited capabilities, please refer to product data for approved combinations.
XL19i
Table SH-1-B — XL16i Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Uncrated Shipping Line Size
Model Power Cooling Metering Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Device H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 5
4TWX6024B1000A 230/1/60 24,000 TXV-NB 44 33 30 260 72 12 20 /8 /16
3 3
4TWX6036B1000A 230/1/60 36,000 TXV-NB 46 37 34 305 71 24 40 /4 /8
7 3
4TWX6048B1000A 230/1/60 48,000 TXV-NB 50 37 34 320 74 29 50 /8 /8
7 3
4TWX6060B1000A 230/1/60 60,000 TXV-NB 50 37 34 362 74 35 60 /8 /8

XL16i
Table SC-1-C — XL15i Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TWX5024A1000A 208/230/1/60 24,000 TXV-NB 42 37 34 273 74 14 20 /4 /16
3 5
2TWX5030A1000A 208/230/1/60 30,000 TXV-NB 46 37 34 290 71 20 30 /4 /16
7 3
2TWX5036A1000A 208/230/1/60 36,000 TXV-NB 50 37 34 304 74 20 30 /8 /8
7 3
2TWX5042A1000A 208/230/1/60 42,000 TXV-NB 50 37 34 314 72 23 35 /8 /8
2TWX5048A1000A 208/230/1/60 48,000 TXV-NB 50 37 34 342 74 26 40 11/8 3
/8

XL15i
Table SH-1-D — XL14i Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 242 71 8 15 /8 /4
3 5
2TWX4024B1000A 200/230/1/60 24,000 TXV-NB 44 33 30 256 74 11 15 /4 /16
3 5
2TWX4030B1000A 208/230/1/60 30,000 TXV-NB 42 37 34 275 73 18 30 /4 /16
7 3
2TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 294 74 21 35 /8 /8
7 3
2TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 309 74 24 40 /8 /8
2TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 313 74 28 45 11/8 3
/8
2TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 340 74 34 50 11/8 3
/8
XL14i
Table SH-1-E — XL14i Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TWX4018B1000A 200/230/1/60 18,000 TXV-NB 40 33 30 224 74 10 15 /2 /4
5 5
4TWX4024B1000A 200/230/1/60 24,000 TXV-NB 48 33 30 239 74 13 20 /8 /16
3 5
4TWX4030B1000A 208/230/1/60 30,000 TXV-NB 48 33 30 242 71 20 30 /4 /16
3 3
4TWX4036B1000A 208/230/1/60 36,000 TXV-NB 46 37 34 259 72 21 35 /4 /8
3 3
4TWX4042B1000A 208/230/1/60 42,000 TXV-NB 50 37 34 274 74 25 40 /4 /8
7 3
4TWX4048B1000A 208/230/1/60 48,000 TXV-NB 50 37 34 280 74 30 50 /8 /8
7 3
XL14i 4TWX4060B1000A 208/230/1/60 60,000 TXV-NB 50 37 34 318 74 36 60 /8 /8
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SH-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

XL19i XL16i XL15i XL14i XL14i


Table SH-2-A — Features (2TWZ9) (4TWX6) (2TWX5) (2TWX4) (4TWX4)
• SEER’s up to .......................................................................................................... 17.90 17.00 16.50 15.00 15.00
• HSPF’s up to .......................................................................................................... 8.8 9.2 9.0 9.0 9.0
• Climatuff™ compressor ........................................................................................ 2 1 - staged ✔ ✔ ✔
• Comfort”R”™ mode approved ............................................................................. ✔ ✔ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ............................................. ✔ ✔ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & .............................................................. ✔ ✔ ✔ ✔ ✔
refrigerant connections with full coil protection
• Spine Fin™ coil ..................................................................................................... ✔ ✔ ✔ ✔ ✔
• Weatherguard™ II top .......................................................................................... ✔ ✔ ✔ ✔ ✔
• Compressor sound enclosure ................................................................................ ✔ ✔ ✔ ✔ ✔
• Compressor sump heat - factory installed .............................................................. 2½-5 5 2-4 1½-2 & 3½-5 1½-2
• Factory supplied charge ......................................................................................... R-22 R-410A R-22 R-22 R-410A
• Glossy corrosion resistant finish ............................................................................ ✔ ✔ ✔ ✔ ✔
• High pressure switch .............................................................................................. — ✔ — — ✔
• Internal high / low pressure & temperature protection ............................................ ✔ ✔ ✔ ✔ ✔
• Liquid line filter drier - factory installed ................................................................... ✔ ✔ ✔ ✔ ✔
• Quick start kit - factory installed ............................................................................. 2½-5 5 — 1½-2 & 5 1½-2 & 5
• Seacoast shield - factory installed .......................................................................... ✔ ✔ ✔ ✔ ✔
• Tarpaulin gray cabinet ............................................................................................ ✔ ✔ ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & parts .............................. ✔ ✔ ✔ ✔ ✔
(Residential)
• Extended warranties available ............................................................................... ✔ ✔ ✔ ✔ ✔

Table SH-2-B — Optional Accessories


AY28X079 .............. Evaporator defrost control kit ..................................................... ✔ ✔ ✔ ✔ ✔
BAYCCHT301 ........ Crank Case Heater Kit (Scroll Compressors) ............................ — 2-4 — 2½-3 2½-5
BAYECMT001 ........ Extreme Condition Mounting Kit ................................................ ✔ ✔ ✔ ✔ ✔
BAYISLT101 .......... Rubber Isolators ........................................................................ ✔ ✔ ✔ ✔ ✔
BAYKSKT260 ........ Quick start kit (21/2 - 4 ton) (Scroll Compressors) ..................... — 2-4 2-4 2½-4 2½-4
BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) .............................. ✔ ✔ ✔ ✔ ✔
BAYLEGS003 ........ 4" Extension (Black) .................................................................. ✔ ✔ ✔ ✔ ✔
TAYASCT501A12 . Anti-Short Cycle Timer .............................................................. ✔ ✔ ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section


1 Do not use with programmable thermostats.
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SH-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

Table SH-3-A — XR14 Split System Heat Pump — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TWR4018A1000A 200-230/1/60 18,000 TXV-NB 37 33 30 236 76 10 15 /2 /4
5 5
4TWR4024A1000A 200-230/1/60 24,000 TXV-NB 41 33 30 251 74 13 20 /8 /16
3 5
4TWR4030A1000A 208-230/1/60 30,000 TXV-NB 41 33 30 253 74 20 30 /4 /16
3 3
4TWR4036A1000A 208-230/1/60 36,000 TXV-NB 37 37 34 276 77 21 35 /4 /8
3 3
4TWR4042A1000A 208-230/1/60 42,000 TXV-NB 41 37 34 290 77 25 40 /4 /8
XR14 4TWR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 297 76 30 50 7
/8 3
/8
7 3
4TWR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 335 79 36 60 /8 /8

Table SH-3-B — XR14 Split System Heat Pump — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWR4018A1000A 200-230/1/60 18,000 TXV-NB 33 33 30 229 75 8 15 /8 /4
3
2TWR4024A1000A 200-230/1/60 24,000 TXV-NB 37 33 30 242 76 11 15 /4 5/16
3
2TWR4030A1000A 208-230/1/60 30,000 TXV-NB 33 37 34 254 76 18 30 /4 5/16
7 3
2TWR4036A1000A 208-230/1/60 36,000 TXV-NB 37 37 34 273 78 21 35 /8 /8
7 3
2TWR4042A1000A 208-230/1/60 42,000 TXV-NB 41 37 34 286 77 24 40 /8 /8
2TWR4048A1000A 208-230/1/60 48,000 TXV-NB 41 37 34 291 77 28 45 1 1/8 3/8
XR14
2TWR4060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 315 76 34 50 1 1/8 3/8

Table SH-3-C — XR13 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWR3018A1000A 200-230/1/60 18,000 TXV-NB 33 29 26 202 73 8 15 /8 /4
3 5
2TWR3024A1000A 200-230/1/60 24,000 TXV-NB 33 29 26 205 76 12 20 /4 /16
3
2TWR3030A1000A 200-230/1/60 30,000 TXV-NB 37 33 30 242 76 13 20 /4 5/16
7 3
2TWR3036A1000A 200-230/1/60 36,000 TXV-NB 37 37 34 292 76 19 30 /8 /8
7 3
2TWR3042A1000A 200-230/1/60 42,000 TXV-NB 41 37 34 309 78 21 35 /8 /8
2TWR3048A1000A 200-230/1/60 48,000 TXV-NB 41 37 34 315 76 25 40 1 1/8 3/8
XR13
2TWR3060A1000A 208-230/1/60 60,000 TXV-NB 41 37 34 321 73 32 50 1 1/8 3/8
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SH-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

XR14 XR14 XR13


Table SH-4-A — Features (4TWR4) (2TWR4) (2TWR3)
• SEER’s up to ......................................................................................................................................................... 14.00 14.00 14.00
• HSPF’s up to ......................................................................................................................................................... 9.0 9.0 8.5
• Climatuff™ compressor ....................................................................................................................................... ✔ ✔ ✔
• Comfort”R”™ mode approved ............................................................................................................................ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................... ✔ ✔ ✔
• Spine Fin™ coil .................................................................................................................................................... ✔ ✔ ✔
• Compressor sound enclosure ............................................................................................................................... ✔ ✔ ✔
• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-5 1½-5
• Factory supplied charge ........................................................................................................................................ R-410A R-22 R-22
• Glossy corrosion resistant finish ........................................................................................................................... ✔ ✔ ✔
• High pressure switch ............................................................................................................................................. ✔ — —
• Low pressure switch ............................................................................................................................................. — — ✔
• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔
• Quick start kit - factory installed ............................................................................................................................ 1½-2,5 1½-2,5 1½-5
• Tarpaulin gray cabinet ........................................................................................................................................... ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔
• Extended warranties available .............................................................................................................................. ✔ ✔ ✔

Table SH-4-B — Optional Accessories


AY28X079 .............. Evap. Defrost Control Kit .......................................................................................................... ✔ ✔ ✔
BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔
BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔
BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. 2½-4 2½-4 —
BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ............................................................................. ✔ ✔ ✔
BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔
BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... — ✔ ✔
BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔
TAYASCT501A12 . Anti-Short Cycle Timer ............................................................................................................. ✔ ✔ ✔

Comfort Controls — See Comfort Controls/Zone Sensors Section


1 Do not use with programmable thermostats.
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SH-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

Table SH-5-A — XR12 Split System Heat Pump — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
1 1
4TWR2018A1000A 200/230/1/60 18,000 .047 33 33 30 221 77 10 15 /2 /4
5 5
4TWR2024A1000A 200/230/1/60 24,000 .053 33 33 30 225 78 14 20 /8 /16

PHASED OUT
3 5
4TWR2030A1000A 208/230/1/60 30,000 .059 33 33 30 234 74 20 30 /4 /16
3 3
4TWR2036A1000A 208/230/1/60 36,000 .063 41 33 30 257 77 21 35 /4 /8
3 3
4TWR2042A1000A 208/230/1/60 42,000 .069 41 33 30 262 79 26 45 /4 /8
XR12 4TWR2048A1000A 208/230/1/60 48,000 .075 33 37 34 271 79 30 50 7
/8 3
/8
4TWR2060A1000A 208/230/1/60 60,000 1 41 37 34 302 81 36 60 7
/8 3
/8

Table SH-5-B — XR12 Split System Heat Pump — Single Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWR2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 79 10 15 /8 /4
3 5
2TWR2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 78 13 20 /4 /16

PHASED OUT
3 5
2TWR2030B1000A 208/230/1/60 30,000 .065 29 29 26 187 99 18 30 /4 /16
7 3
2TWR2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 /8 /8
7 3
2TWR2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 /8 /8
XR12 2TWR2048A1000B 208/230/1/60 48,000 .086 37 33 30 256 99 26 45 11/8 3
/8
2TWR2060A1000A 208/230/1/60 60,000 1 41 37 34 316 80 37 60 11/8 3
/8

Table SH-5-C — XR11 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWR1018A1000A 200/230/1/60 18,000 0.049 26 29 26 168 77 10 15 /8 /4
3 5
2TWR1024A1000A 200/230/1/60 24,000 0.057 26 29 26 176 77 15 25 /4 /16

PHASED OUT
3 5
2TWR1030A1000A 200/230/1/60 30,000 0.069 29 29 26 187 79 18 30 /4 /16
7 3
2TWR1036A1000A 200/230/1/60 36,000 0.069 29 29 26 190 79 21 35 /8 /8
7 3
2TWR1042A1000A 200/230/1/60 42,000 0.077 33 33 30 253 79 23 40 /8 /8
XR11 2TWR1048A1000A 200/230/1/60 48,000 0.083 33 33 30 259 80 30 50 11/8 3
/8
2TWR1060A1000A 200/230/1/60 60,000 1 33 37 34 292 81 34 50 11/8 3
/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SH-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

XR12 XR12 XR11


Table SH-6-A — Features (4TWR2) (2TWR2) (2TWR1)

T
• SEER’s up to .................................................................................................................................................................. 13.00 13.00 11.50
• HSPF’s up to .................................................................................................................................................................. 9.25 10.15 8.50

OU
• Climatuff™ compressor ................................................................................................................................................ ✔ ✔ ✔
• Comfort”R”™ mode approved ...................................................................................................................................... ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ...................................................................................................... ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection ............................................... ✔ ✔ ✔

ED
• Spine Fin™ coil ............................................................................................................................................................. ✔ ✔ ✔
• Factory installed start kit ................................................................................................................................................. 1-2 & 5 1-2 —
• Factory supplied charge ................................................................................................................................................. R-410A R-22 R-22

AS
• Glossy corrosion resistant finish ..................................................................................................................................... ✔ ✔ ✔
• High pressure switch ...................................................................................................................................................... ✔ — —
• Internal high / low pressure & temperature protection ..................................................................................................... ✔ ✔ ✔

PH
• Liquid line filter drier - factory installed ............................................................................................................................ ✔ ✔ ✔
• Tarpaulin gray cabinet .................................................................................................................................................... ✔ ✔ ✔
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) .................................................. ✔ ✔ ✔
• Extended warranties available ........................................................................................................................................ ✔ ✔ ✔

Table SH-6-B — Optional Accessories


AY28X079 ............... Evap. Defrost Control Kit .................................................................................................................. ✔ ✔ ✔
✔ ✔ ✔

T
BAY24X045 ............. ID Fan Delay Relay Kit .....................................................................................................................
BAYCCHT300 ......... Crankcase Heater Kit (Reciprocating Compressors) ........................................................................ 1½-2 1½-2 1½-5

OU
BAYCCHT301 ......... Crankcase Heater Kit (Scroll Compressors) ..................................................................................... 2½-5 2½-5 —
BAYECMT001 ......... Extreme Condition Mounting Kit ....................................................................................................... ✔ ✔ ✔
BAYISLT101 ............ Rubber Isolators ............................................................................................................................... ✔ ✔ ✔
BAYKSKT257 .......... Start Kit (Reciprocating Compressors) ............................................................................................. — — 2½-5

ED
BAYKSKT260 .......... Start Kit (Scroll Compressors) .......................................................................................................... 2½-4 2½-5 —
BAYLEGS002 .......... Snow Legs - Base and Cap 6" High (Black) ..................................................................................... ✔ ✔ ✔
✔ ✔ ✔

AS
BAYLEGS003 .......... 4" Extension (Black) .........................................................................................................................
BAYLOAM103 ......... Low Ambient Kit ............................................................................................................................... — ✔ 2½-5
BAYLOAM104 ......... Low Ambient Kit with Start Kit .......................................................................................................... — — 1½-2

PH
BAYSDEN001 ......... Single Cylinder Compressor Enclosures .......................................................................................... — — 1½-2
BAYSDEN003 ......... Small Scroll Compressor Enclosures ................................................................................................ — 2½-4 —
BAYSEAC001 ......... Seacoast Kit ..................................................................................................................................... ✔ ✔ ✔

Table SH-6-C — Comfort Controls


TAYASCT501A12 .. Anti-Short Cycle Timer ..................................................................................................................... ✔ ✔ ✔
TAYSENS100A ....... Outdoor Temp. Sensor (with case) ................................................................................................... ✔ ✔ ✔
TAYSTAT241 .......... Manual 2 Htg/1 Clg ........................................................................................................................... ✔ ✔ ✔
✔ ✔ ✔
TAYSTAT250B ........ Outdoor Thermostat .........................................................................................................................
T
TAYSTAT300C ........ XT300C Prog., 7 Day, A/M,1Htg/1Clg .............................................................................................. ✔ ✔ ✔
OU
TAYSTAT302C ........ XT302C Prog., 7 Day, A/M,2Htg/2Clg .............................................................................................. ✔ ✔ ✔
TAYSTAT340 .......... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ................................................................................................. ✔ ✔ ✔
TAYSTAT350 .......... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1Clg ........................................................................................ ✔ ✔ ✔
TAYSTAT370 .......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ........................................................................................ ✔ ✔ ✔
ED

TAYSTAT371 .......... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) ...................................................................................... ✔ ✔ ✔


TAYSTAT375 .......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable ....................................................... ✔ ✔ ✔
TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ........................................................................................ ✔ ✔ ✔
AS

TCONT200A ............ Electronic, 1Htg/1Clg (Gas/Elec./Oil) ................................................................................................ ✔ ✔ ✔


TCONT401A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔
TCONT402A ............ 3Heat/2Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔
PH

TCONT600A ............ 1Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔


TCONT602A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔
TCONT800A ............ 2Heat/1Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔
TCONT802A ............ 3Heat/2Clg (Heat Pump/A/C) ........................................................................................................... ✔ ✔ ✔
TCONT803A ............ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ............................................................................. ✔ ✔ ✔
1 Do not use with programmable thermostats.
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SH-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

Table SH-7-A — XB13 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWB3018A1000A 200-230/1/60 17,000 TXV-NB 33 29 26 202 74 8 15 /8 /4
3 5
2TWB3024A1000A 200-230/1/60 23,000 TXV-NB 33 29 26 205 79 12 20 /4 /16
3
2TWB3030A1000A 200-230/1/60 28,500 TXV-NB 37 33 30 240 79 13 20 /4 5/16
7 3
2TWB3036A1000A 200-230/1/60 34,500 TXV-NB 37 37 34 291 79 19 30 /8 /8
7 3
2TWB3042A1000A 200-230/1/60 40,500 TXV-NB 41 37 34 308 80 21 35 /8 /8
XB13 2TWB3048A1000A 200-230/1/60 46,500 TXV-NB 41 37 34 312 78 25 40 1 1/8 3/8
2TWB3060A1000A 208-230/1/60 58,500 TXV-NB 41 37 34 318 79 32 50 1 1/8 3/8

Table SH-7-B — XB12 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWB2018A1000A 200/230/1/60 18,000 .049 26 29 26 176 81 10 15 /8 /4
3 5
2TWB2024A1000A 200/230/1/60 24,000 .059 29 29 26 191 82 13 20 /4 /16

PHASED OUT
3 5
2TWB2030A1000A 208/230/1/60 30,000 .065 29 29 26 187 79 18 30 /4 /16
7 3
2TWB2036A1000A 208/230/1/60 36,000 .071 33 33 30 233 77 21 35 /8 /8
7 3
2TWB2042A1000A 208/230/1/60 42,000 .077 33 33 30 229 79 24 40 /8 /8
2TWB2048A1000A 208/230/1/60 48,000 .086 37 33 30 256 79 26 45 11/8 3
/8
XB12 2TWB2060A1000A 208/230/1/60 60,000 1 41 37 34 316 80 37 60 11/8 3
/8

Table SH-7-C— XB10 Weathertron® Split System Heat Pump — Single Phase
Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
5 1
2TWB0012A1000A 200/230/1/60 12,000 .047 26 29 26 169 79 10 15 /8 /4
5 1
2TWB0018A1000A 200/230/1/60 18,000 .049 26 29 26 169 79 10 15 /8 /4

PHASED OUT
3 5
2TWB0024A1000A 200/230/1/60 24,000 .057 26 29 26 177 79 15 25 /4 /16
3 5
2TWB0030A1000A 200/230/1/60 30,000 .067 29 29 26 187 81 17 25 /4 /16
7 3
2TWB0036A1000A 200/230/1/60 36,000 .067 29 29 26 189 81 20 30 /8 /8
7 3
2TWB0042A1000A 200/230/1/60 42,000 .075 33 33 30 247 79 23 40 /8 /8
2TWB0048A1000A 200/230/1/60 48,000 .083 33 33 30 255 80 26 40 11/8 3
/8
XB10 2TWB0060A1000A 200/230/1/60 60,000 1 33 37 34 291 81 34 50 11/8 3
/8
1 Indoor Metering device TXV only.

For complete equipment / combination


selections and installation instructions, please SH-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Single Phase – 1½ through 5 Tons

XB13 XB12 XB10


Table SH-8-A — Features (2TWB3) (2TWB2) (2TWB0)
• SEER’s up to ......................................................................................................................................................... 13.25 12.50 10.50
• HSPF’s up to ......................................................................................................................................................... 8.0 9.10 8.15

T
• Climatuff™ compressor ....................................................................................................................................... ✔ ✔ ✔

OU
• Comfort”R”™ mode approved ............................................................................................................................ ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof ............................................................................................ ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................... ✔ ✔ ✔
• Spine Fin™ coil .................................................................................................................................................... ✔ ✔ ✔

ED
• Compressor sound enclosure ............................................................................................................................... 3-4 4-5 4-5
• Compressor sump heat - factory installed ............................................................................................................. 1½-5 1½-2,4-5 1½-5
• Factory supplied charge ........................................................................................................................................ R-22 R-22 R-22

AS
• Glossy corrosion resistant finish ........................................................................................................................... ✔ ✔ ✔
• Low pressure switch ............................................................................................................................................. ✔ — —
• Internal high / low pressure & temperature protection ........................................................................................... ✔ ✔ ✔

PH
• Liquid line filter drier - factory installed .................................................................................................................. ✔ ✔ ✔
• PolySlate gray cabinet .......................................................................................................................................... ✔ ✔ ✔
• Quick start kit - factory installed ............................................................................................................................ 1½-5 1½-2,5 —
• 10-year limited warranty on compressor, outdoor coil & 5 years on parts (Residential) ........................................ ✔ ✔ ✔
• Extended warranties available .............................................................................................................................. ✔ ✔ ✔

Table SH-8-B — Optional Accessories


AY28X079 .............. Evap. Defrost Control Kit .......................................................................................................... ✔ ✔ ✔

OUT
BAYCCHT301 ........ Crankcase Heater Kit (Scroll Compressors) ............................................................................. — 2½-3½ —
BAYECMT001 ........ Extreme Condition Mounting Kit ............................................................................................... ✔ ✔ ✔
BAYISLT101 .......... Rubber Isolators ....................................................................................................................... ✔ ✔ ✔
BAYKSKT257 ........ Start Kit (Reciprocating Compressors) ..................................................................................... — — 1-5
BAYKSKT260 ........ Start Kit (Scroll Compressors) .................................................................................................. — 2½-4 —

SED
BAYLEGS002 ........ Snow Legs - Base and Cap 6" High (Black) ............................................................................. ✔ ✔ ✔
BAYLEGS003 ........ 4" Extension (Black) ................................................................................................................. ✔ ✔ ✔
BAYLOAM103 ........ Low Ambient Kit ....................................................................................................................... ✔ ✔ ✔
BAYSDEN001 ........ Single Cylinder Compressor Enclosures .................................................................................. 1½-2 1-3 ?

PHA
BAYSDEN002 ........ Two Cylinder Compressor Enclosures ..................................................................................... — 3½ ?
BAYSDEN003 ........ Small Scroll Compressor Enclosures ....................................................................................... 2½ -— ?
BAYSDEN004 ........ Large Scroll Compressor Enclosures ....................................................................................... 5 — ?
BAYSEAC001 ........ Seacoast Kit ............................................................................................................................. ✔ ✔ ✔

Table SH-8-C — Comfort Controls


TAYASCT501A12 . Anti-Short Cycle Timer ............................................................................................................. ✔ ✔
TAYSENS100A ...... Outdoor Temp. Sensor (with case) ........................................................................................... ✔ ✔
TAYSTAT241 ......... Manual 2 Htg/1 Clg ................................................................................................................... ✔ ✔
OUT
TAYSTAT250B ...... Outdoor Thermostat ................................................................................................................. ✔ ✔
TAYSTAT300C ...... XT300C Prog., 7 Day, A/M,1Htg/1Clg ...................................................................................... ✔ ✔
TAYSTAT302C ...... XT302C Prog., 7 Day, A/M,2Htg/2Clg ...................................................................................... ✔ ✔
Zone Sensors Section
See Comfort Controls/

TAYSTAT340 ......... Prog., 5/2 Day, Manual, 1 Htg/1 Clg ......................................................................................... ✔ ✔


TAYSTAT350 ......... Prog., 5/2 Day, Manual, 2 (Gas) Htg/1Clg ................................................................................ ✔ ✔
TAYSTAT370 ......... Electronic, 1Htg (Gas) /1 Clg ( Non Prog.) ............................................................................... ✔ ✔
SED

TAYSTAT371 ......... Electronic, 1Htg (Elec.) /1 Clg ( Non Prog.) .............................................................................. ✔ ✔


TAYSTAT375 ......... Electronic, 2Htg (Gas/Elec.) 2 Clg (Non Prog.) Field Selectable .............................................. ✔ ✔
TAYSTAT380 ......... Electronic, 2 Htg (Gas)/ 1 Clg (Non Prog.) ............................................................................... ✔ ✔
TCONT200A .......... Electronic, 1Htg/1Clg (Gas/Elec./Oil) ....................................................................................... ✔ ✔
PHA

TCONT401A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔


TCONT402A .......... 3Heat/2Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔
TCONT600A .......... 1Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔
TCONT602A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔
TCONT800A .......... 2Heat/1Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔
TCONT802A .......... 3Heat/2Clg (Heat Pump/A/C) ................................................................................................... ✔ ✔
TCONT803A .......... 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control .................................................................... ✔ ✔
1 Do not use with programmable thermostats.
2 Activated on Power Off.

For complete equipment / combination


Effective 1/1/06 SH-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Three Phase – 2½ through 6 Tons

Table SH-9-A — Split System Heat Pump — Three Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TWA0030A3000A 200-230/3/60 30,000 .069 29 29 26 193 82 13 20 /4 /16
7 3
2TWA0036A3000A 200-230/3/60 36,000 .069 29 29 26 192 80 15 25 /8 /8
7 3
2TWA0042A3000A 200-230/3/60 42,000 .077 33 33 30 250 81 17 30 /8 /8
2TWA0048A3000A 200-230/3/60 48,000 .083 33 33 30 254 81 19 30 11/8 3
/8
2TWA0060A3000A 200-230/3/60 60,000 1 33 37 34 289 84 25 40 11/8 3
/8
2TWA0 2TWA0072A3000A 200-230/3/60 72,000 1 41 37 34 327 81 26 40 11/8 3
/8

3 5
2TWA0030A4000A 460/3/60 30,000 .069 29 29 26 193 82 7 15 /4 /16
7 3
2TWA0036A4000A 460/3/60 36,000 .069 29 29 26 192 80 7 15 /8 /8
7 3
2TWA0042A4000A 460/3/60 42,000 .077 33 33 30 250 81 9 15 /8 /8
2TWA0048A4000A 460/3/60 48,000 .083 33 33 30 254 81 10 15 11/8 3
/8
2TWA0060A4000A 460/3/60 60,000 1 33 37 34 289 84 12 20 11/8 3
/8
2TWA0072A4000A 460/3/60 72,000 1 41 37 34 327 81 14 20 11/8 3
/8

Table SH-9-B — Split System Heat Pump — Three Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3
2TWA3030A3000A 200-230/3/60 30,000 TXV-NB 37 33 30 239 77 9 15 /4 5/16
7 3
2TWA3036A3000A 200-230/3/60 36,000 TXV-NB 37 37 34 285 79 11 15 /8 /8
7 3
2TWA3042A3000A 200-230/3/60 42,000 TXV-NB 41 37 34 304 80 13 20 /8 /8
2TWA3048A3000A 200-230/3/60 48,000 TXV-NB 41 37 34 309 78 16 25 1 1/8 3/8
2TWA3060A3000A 200-230/3/60 60,000 TXV-NB 41 37 34 303 73 23 40 1 1/8 3/8
2TWA3
3
2TWA3030A4000A 460/3/60 30,000 TXV-NB 37 33 30 239 77 5 15 /4 5/16
7 3
2TWA3036A4000A 460/3/60 36,000 TXV-NB 37 37 34 286 79 6 15 /8 /8
7 3
2TWA3042A4000A 460/3/60 42,000 TXV-NB 41 37 34 305 80 7 15 /8 /8
2TWA3048A4000A 460/3/60 48,000 TXV-NB 41 37 34 310 78 9 15 1 1/8 3/8
2TWA3060A4000A 460/3/60 60,000 TXV-NB 41 37 34 304 73 11 15 1 1/8 3/8

Table SH-9-C — Split System Heat Pump — Three Phase


Nom. Cap. Required Uncrated Shipping Line Size
Model Power Cooling FCCV Dimensions(in.) Weight Sound** Max. OD OD
Number Supply (BTUH) Size H W D (lbs.) Rating MCA* Fuse* Gas Liq.
3 5
2TWA2030A3000A 200-230/3/60 30,000 .065 29 29 26 185 79 12 20 /4 /16
7 3
2TWA2036A3000A 200-230/3/60 36,000 .071 33 33 30 228 77 14 20 /8 /8
7 3
2TWA2042A3000A 208-230/3/60 42,000 .077 33 33 30 224 79 17 25 /8 /8
2TWA2048A3000A 208-230/3/60 48,000 .086 37 33 30 251 79 20 30 11/8 3
/8

PHASED OUT
2TWA2060A3000A 208-230/3/60 60,000 1 41 37 34 303 80 23 40 11/8 3
/8

2TWA2 3 5
2TWA2030A4000A 460/3/60 30,000 .065 29 29 26 188 79 6 15 /4 /16
7 3
2TWA2036A4000A 460/3/60 36,000 .071 33 33 30 228 77 7 15 /8 /8
7 3
2TWA2042A4000A 460/3/60 42,000 .077 33 33 30 224 79 8 15 /8 /8
2TWA2048A4000A 460/3/60 48,000 .086 37 33 30 250 79 10 15 11/8 3
/8
2TWA2060A4000A 460/3/60 60,000 1 41 37 34 303 80 12 20 11/8 3
/8
1 Indoor Metering device TXV only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Rated in accordance with ARI Standard 270, section 5.3.6.

For complete equipment / combination


selections and installation instructions, please SH-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Three Phase – 2½ through 6 Tons

Table SH-10-A — Features 2TWA0 2TWA3 2TWA2


• SEER’s up to ....................................................................................................................................................... 11.75 14.50 12.5
• HSPF .................................................................................................................................................................. 8.2 8.8 9.75

PHASED OUT
• Climatuff™ compressor ..................................................................................................................................... ✔ ✔ ✔
• Comfort”R”™ mode approved .......................................................................................................................... ✔ ✔ ✔
• DuraTuff™ base, fast complete drain, weatherproof .......................................................................................... ✔ ✔ ✔
• Quick-Sess™ cabinet, service access & refrigerant connections with full coil protection .................................. ✔ ✔ ✔
• Spine Fin™ coil .................................................................................................................................................. ✔ ✔ ✔
• Compressor sump heat - factory installed ........................................................................................................... 2½-6 2½-5 2½-5
• Factory supplied charge ...................................................................................................................................... R-22 R-22 R-22
• Glossy corrosion resistant finish ......................................................................................................................... ✔ ✔ ✔
• Internal high / low pressure & temperature protection ......................................................................................... ✔ ✔ ✔
• Liquid line filter drier - factory installed ................................................................................................................ ✔ ✔ ✔
• Low pressure switch ........................................................................................................................................... ✔ ✔ ✔
• PolySlate gray cabinet ........................................................................................................................................ ✔ ✔ ✔
• 5-year limited warranty on compressor, and 1 year on coil and parts (Commercial) ........................................... ✔ ✔ ✔
• 5-year limited warranty on compressor, coil and 1 year on parts (Residential) ................................................... ✔ ✔ ✔
• Extended warranties available ............................................................................................................................ ✔ ✔ ✔

Table SH-10-B — Optional Accessories


AY28X079 ...................... Evaporator Defrost Control ............................................................................................. ✔ ✔ ✔

PHASED OUT
BAYECMT001 ................ Extreme Condition Mounting Kit ..................................................................................... ✔ ✔ ✔
BAYISLT101 .................. Rubber Isolators ............................................................................................................. ✔ ✔ ✔
BAYLEGS002 ................ Snow Legs - Base and Cap 6" High (Black) ................................................................... ✔ ✔ ✔
BAYLEGS003 ................ 4" Extension (Black) ....................................................................................................... ✔ ✔ ✔
BAYLOAM103 ................ Electronic Head Pressure Control .................................................................................. ✔ ✔ ✔
BAYSDEN001 ................ Single Cylinder Compressor Enclosures ........................................................................ 2½-3 2½ —
BAYSDEN002 ................ Two Cylinder Compressor Enclosures ........................................................................... 3½-5 3-4 —
BAYSDEN003 ................ Small Scroll Compressor Enclosures ............................................................................. — — 2½-4
BAYSDEN004 ................ Large Scroll Compressor Enclosures ............................................................................. 6 5 5
BAYSEAC001 ................ Seacoast Kit ................................................................................................................... ✔ ✔ ✔
TAYASCT501A12 ........ Anti-Short Cycle Timer ................................................................................................... ✔ ✔ ✔

Table SH-10-C — Comfort Controls


TAYSENS100A ............. Outdoor Temp. Sensor (with case) ................................................................................ ✔

PHASED OUT
TAYSTAT241 ................. Manual 2 Stg Htg/1 Clg .................................................................................................. ✔
TAYSTAT250B .............. Outdoor Thermostat ....................................................................................................... ✔
TAYSTAT300C ............. XT300C Prog.,7 Day,A/M,1Htg/1Clg .............................................................................. ✔
Zone Sensors Section

Zone Sensors Section


See Comfort Controls/

See Comfort Controls/

TAYSTAT340 ................. Prog., 5/2 Day, Manual, 1 Htg/1 Clg ............................................................................... ✔


TAYSTAT350 ................. Prog., 5/2 Day, Manual, 2 (Gas) Htg/1 Clg ..................................................................... ✔
TAYSTAT370 ................. Electronic, 1Htg(Gas)/1Clg(Non Prog.) .......................................................................... ✔
TAYSTAT371 ................. Electronic, 1Htg(Elec)/1Clg(Non Prog.) .......................................................................... ✔
TAYSTAT380 ................. Electronic, 2 Htg (Gas) 1 Clg(Non Prog.) ....................................................................... ✔
TCONT200A .................. Electronic, 1Htg/1Clg (Gas/Elec./Oil) ............................................................................. ✔
TCONT401A .................. 2Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔
TCONT402A .................. 3Heat/2Clg (Heat Pump/A/C) ......................................................................................... ✔
TCONT600A .................. 1Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔
TCONT602A .................. 2Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔
TCONT800A .................. 2Heat/1Clg (Heat Pump/A/C) ......................................................................................... ✔
TCONT802A .................. 3Heat/2Clg (Heat Pump/A/C) ......................................................................................... ✔
TCONT803A .................. 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control .......................................................... ✔
1 Do not use with programmable thermostats
2 Activated on Power Off.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 SH-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Three Phase – 7½ through 20 Tons

• Single refrigerant circuit on 7½ and 10 ton • Internal pressure relief valve


sizes (Trane 3-D® Scroll compressor) • Single side service access for reduced
• Dual refrigerant circuits on 15 and 20 ton maintenance cost
sizes. (Two Trane 3-D® Scroll compressors) • Factory installed refrigerant drier to increase
• Service valves with pressure taps reliability
• Utilizes Trane compressor(s) for high • Brazed refrigerant piping connections
reliability and long life • Powder paint
• Vertical upflow condenser discharge • Low ambient cooling to 50°F as shipped.
• Electronic time/temp. defrost control • 5-year compressor warranty through 15
TWA – 7½ through 20 Tons • Plate type aluminum fin/copper enhanced tons, 1-year limited parts warranty
tube condenser heat transfer for high • 1-year compressor warranty on
efficiency to reduce energy consumption 20 ton unit, 1-year limited parts warranty
• High/low pressure cut-out switches
Table SH-11-A— TWA Split System Heat Pump — Single Compressor
Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.
TWA090A300F — 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 13/8 1
/2
TWA120A300F — 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 13/8 1
/2

TWA090A400F — 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 13/8 1


/2
TWA120A400F — 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 13/8 1
/2

TWA090AW00F — 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 25 13/8 1


/2
TWA120AW00F — 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 35 13/8 1
/2

Table SH-11-B— TWA Split System Heat Pump — Dual Compressor


Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.
TWA180B300F — 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 13/8 1
/2
TWA240B300F — 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 13/8 1
/2

TWA180B400F — 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 13/8 1


/2
TWA240B400F — 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 13/8 1
/2

TWA180BW00F — 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 13/8 1


/2
TWA240BW00F — 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 13/8 1
/2

Table SH-11-A — Optional factory installed Black Epoxy Coil for corrosive resistance.
Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.
TWA090A30SF Epoxy Coil 208-230/3/60 91,000 39 34 41 SPR 390 8.8 34.5 50 13/8 1
/2
TWA120A30SF Epoxy Coil 208-230/3/60 124,000 44 38 51 SPR 502 8.8 48.1 70 13/8 1
/2

TWA090A40SF Epoxy Coil 460/3/60 91,000 39 34 41 SPR 390 8.8 18.1 25 13/8 1
/2
TWA120A40SF Epoxy Coil 460/3/60 124,000 44 38 51 SPR 502 8.8 23.3 35 13/8 1
/2

TWA090AW0SF Epoxy Coil 575/3/60 91,000 39 34 41 SPR 390 8.8 14.5 20 13/8 1
/2
TWA120AW0SF Epoxy Coil 575/3/60 124,000 44 38 51 SPR 502 8.8 18.8 25 13/8 1
/2

Table SH-11-B — Optional factory installed Black Epoxy Coil for corrosive resistance.
Factory Nom. Cap. Uncrated Shipping Line Size
Model Installed Power Cooling Dimensions(in.) Mfg. Weight Sound Max OD OD
Number Option Supply (BTUH) H W L Plant (lbs.) Rating MCA Fuse Gas Liq.
TWA180B30SF Epoxy Coil 208-230/3/60 182,000 38 34 88 SPR 816 8.8 62.7 80 13/8 1
/2
TWA240B30SF Epoxy Coil 208-230/3/60 240,000 45 44 94 SPR 934 8.8 87.8 100 13/8 1
/2

TWA180B40SF Epoxy Coil 460/3/60 182,000 38 34 88 SPR 816 8.8 32.9 45 13/8 1
/2
TWA240B40SF Epoxy Coil 460/3/60 240,000 45 44 94 SPR 934 8.8 42.5 50 13/8 1
/2

TWA180BW0SF Epoxy Coil 575/3/60 182,000 38 34 88 SPR 816 8.8 26.3 35 13/8 1
/2
TWA240BW0SF Epoxy Coil 575/3/60 240,000 45 44 94 SPR 934 8.8 34.2 45 13/8 1
/2
1 Sound Rating shown is tested in accordance with ARI standard 270 or 370.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
For complete equipment / combination
selections and installation instructions, please SH-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Heat Pumps
Three Phase – 7½ through 20 Tons

Table SH-12-A — Optional Accessories


Model
Number Description Used With
BAYISLT005A ................... Rubber-In-Shear Isolator ................................ TWA090, 120A
BAYISLT009A ................... Rubber-In-Shear Isolator ................................ TWA180B
BAYISLT010A ................... Rubber-In-Shear Isolator ................................ TWA240B
BAYISLT023A ................... Steel Spring Isolator ....................................... TWA090, 120A
BAYISLT024A ................... Steel Spring Isolator ....................................... TWA180B
BAYISLT025A ................... Steel Spring Isolator ....................................... TWA240B
BAYASCT00125 ............. Anti-Short-Cycle Timer ................................... All TWA Models
BAYSTAT033A .................. ODT 45°F to -10°F .......................................... All TWA Models
BAYGARD024A ................ Coil Guard Kit ................................................. TWA090A
BAYGARD038A ................ Coil Guard Kit ................................................. TWA120A
BAYGARD028A ................ Coil Guard Kit ................................................. TWA180B
BAYGARD042A ................ Coil Guard Kit ................................................. TWA240B
BAYLOAM015A1 ............ Head Pressure Control-575V ......................... TWA090W,TWA180BW
BAYLOAMW22A1 ........... Head Pressure Control-575V ......................... TWA120AW,TWA240BW
BAYLOAM326A13 ......... Head Pressure Control-230V ......................... TWA090A3
BAYLOAM327A13 ......... Head Pressure Control-230V ......................... TWA120A3
BAYLOAM328A13 ......... Low Ambient Kit-230V .................................... TWA240B3
BAYLOAM329A13 ......... Low Ambient Kit-230V .................................... TWA180B3
BAYLOAM425A13 ......... Head Pressure Control-460V ......................... TWA090A4
BAYLOAM426A13 ......... Head Pressure Control-460V ......................... TWA120A4
BAYLOAM427A13 ......... Low Ambient Kit-460V .................................... TWA240B4
BAYLOAM428A13 ......... Low Ambient Kit-460V .................................... TWA180B4
BAYLOAM429B67 ......... Low Ambient Fan Cycle Control ..................... TWA090-240A,B,C
BAYRLAY0022 ................ Time Delay Relay ........................................... TWA180-240B, TWA090-120A
TAYSTAT250A .................. Outdoor Thermostat ........................................ All Heat Pump Models

Table SH-12-B — Comfort Controls


Model
Number Description Used With
BAY28X138A .................... 2 Htg/1 Clg Automatic Changeover ................ TWA090-120A
BAY28X153A .................... 3 Htg/2 Clg Automatic Changeover ................ TWA180-240B
BAY28X1902 ................. Locking Thermostat Cover .............................. All Room Thermostats
BAYBASE007A ................ 3 Htg/2 Clg Subbase ....................................... BAYSTAT040B
BAYSENS033A ................ Remote Wall Sensor ....................................... BAYSTAT040B
BAYSENS034A ................ Remote Duct Sensor ...................................... BAYSTAT040B
BAYSTAT040B4 ............. Programmable Thermostat ............................. TWA090-240B
BAYSTAT239 ................... 2 Htg/1 Clg Manual Changeover .................... TWA090-120A
TAYSENS100A ................ Outdoor Temp. Sensor (With Case) ............... TAYSTAT500C,575
TAYSTAT500C ................. XT 500C Prog., 7 Day, Man/Auto ................... All Heat Pump Models
TAYSTAT570 ................... Electronic, 2 Htg/1 Clg (Non Prog.) ................ All Heat Pump Models
1 Quantity 1 required for each fan. (TWA180B, TWA240B)
2 Do not use with programmable thermostats.
3 Requires the use of BAYRLAY005A Interlock Kit.
4 Requires the use of BAYBASE007A.
5 Activated on Power ON.
6 Option is compatible for units with electric mechanical controls unit.
7 Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures.

For complete equipment / combination


Effective 1/1/06 SH-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
TEH AH
TRANE
TRANE 2TEH AIR HANDLER

Trane Profit-ability
Sell-ability
Superior performance and appearance
4-speed fan motor
Air-TiteTM cabinet
Precision engineering
Sound reduction
Matched systems
TRANE LIMITED WARRANTY
5-year functional parts
Install-ability
6-way convertibility
Tonnage 1.5 to 5
Recessed screws
External drain connections

Service-ability
Easy-access control box
Quick filter change with standard filters
External refrigerant components
Easy coil cleaning

Performance-ability QUIET AND HIGHLY EFFICIENT. DESIGNED WITH YOUR CUSTOMER IN MIND.
High efficiency The 2TEH air handler is the right choice for customers is among the quietest units we make. It has a high
400 CFM/ton nominal airflow looking to maximize comfort and efficiency. Ideal for new efficiency blower motor and our unique VorticaTM blower
Thermostatic expansion valve home builders or as a replacement unit for discerning design—all in an attractive, smaller-sized package that
Rely-ability customers, the 2TEH has a 4-speed indoor blower meets or beats the competition for reliability. And that
Best reliability distributing 400 CFM/ton nominal air flow for even, should yield some reliable profits for you.
Quiet internal check valve consistent comfort every month of the year. The 2TEH

Reliable performance Better indoor air Comfort control Enhanced comfort Efficient operation
Precision engineering, design Add a TRANE CleanEffects air
TM
Give your customers better Delivers quiet, even, consistent Increased efficiency
innovation and rigorous testing for cleaner and remove up to 99.98% comfort control with a Trane digital comfort all year round. may substantially lower
reliable, long-lasting performance of airborne allergens from the or programmable thermostat. customers’ utility costs.
and durability. filtered air for a cleaner, more
comfortable home.

15633 2TEH Air Handler.indd 1 11/9/05 4:10:34 PM


TEH AH
TRANE
TRANE 2TEH AIR HANDLER
6

2 1 High efficiency 4-speed indoor 7 Insulated cabinet


blower motor Heavy steel and insulation protects from heating
Provides airflow flexibility to closely match heating and cooling losses, lowers sound levels, and is
and cooling requirements. Delivers exceptional air easy to clean.
1 flow and efficiency.
11 8 Fully gasketed doors
2 Easy-access control box Reduces air leaks to improve efficiency, and
Located behind one easy-to-remove panel for fast decreases overall sound.
5 installation and service. 9 Easy-access filter doors
Features and components may vary by model

10
and are shown for illustration purposes only.

3 “No Leak” base pan Standard off-the-shelf filters located behind one
Rust-resistant, polycarbonate drain pan. Fully easy-to-remove door for quick and convenient
4 sloped to put an end to standing water. filter change.

7 4 Extra-large coil surface 10 External refrigerant drain connections


Enhances heat transfer, provides greater efficiency Provide for faster installation and service.
and more heating and cooling capacity.
8
11 VorticaTM advanced air flow system
5 Recessed screws Improves airflow while reducing energy use and
Will not snag on walls or door facings during operating sound. Durable composite material will
installation. not crack, corrode or rust.
9 3
6 Corrosion-resistant finish
Covers all panels uniformly to resist corrosion.

2TEH AIR HANDLER (R-22 Refrigerant)


Warranties generate additional income.
Nominal Uncrated
Trane extended warranties create additional income. Selling extended
Power Cap. Clg. Ref. Flow Fan Dimensions (in.) warranties is another way to protect your customers and generate
Model Supply (BTUH) Con Control Speed H W D
future business.
2TEH3F18A1000A 200/230/1/60 18,000 BZ TXV-NB 4 43 21.5 21
2TEH3F24A1000A 200/230/1/60 24,000 BZ TXV-NB 4 43 21.5 21
It all adds up to a stellar reputation.
2TEH3F30A1000A 200/230/1/60 30,000 BZ TXV-NB 4 45 21.5 21
2TEH3F36A1000A 200/230/1/60 36,000 BZ TXV-NB 4 45 21.5 21 We know that when you recommend our products to customers, you
2TEH3F42A1000A 200/230/1/60 42,000 BZ TXV-NB 4 51.75 23.5 21 are placing your livelihood and reputation in our hands. We appreciate
2TEH3F48A1000A 200/230/1/60 48,000 BZ TXV-NB 4 57.9 23.5 21 your trust in us, and your dedication to delivering Trane technology and
2TEH3F60A1000A 200/230/1/60 60,000 BZ TXV-NB 4 57.9 23.5 21 innovation to your customers to make their homes better places for
As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice. living. You are the reason we can say, “expect more from Trane.”

trane.com

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. 2TEHAH-01 11/05

15633 2TEH Air Handler.indd 2 11/9/05 4:10:37 PM


Air Handler Convertibility

One Unit – 4 Applications Easy Conversion to Opposite Side Access


Conversion 1 – 4 Conversion 5 – 6

Horizontal Right 1 Unit is shipped as


(as shipped) Horizontal right
Refrigerant connectors

Primary Condensate Airflow


Airflow
Primary
Horizontal Drain Pan Condensate
Coil Supports

Vertical Upflow Airflow 2 Pull coil out and


(as shipped) rotate the coil 180°
One-Step Conversion
Stand unit on end

Airflow

3 Slide coil back in on


Horizontal Left supports and roll unit 180°
Rotate Coil (So primary condensate is down)

Airflow

Airflow

Primary Condensate
Vertical Downflow
One-Step Conversion
from Horizontal left

Six Conversion 4 Note connections


and access are now
Applications on back side of unit
1. Horizontal Right –
Front Access
2. Vertical Upflow Primary
3. Horizontal Left – Condensate
Front Access
4. Vertical Downflow
5. Horizontal Right – Airflow Airflow
Rear Access
6. Horizontal Left –
Rear Access

For complete equipment / combination


selections and installation instructions, please AH-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
"Air-TiteTM"
Features and Benefits

1 Duct Flange – Allows flush fit for 3/4", 1" or 1 1/2" duct insulation heat transfer, and lower power bills.
2 Liner/Flange Seal – Exclusive Duct Flange Thermal 8 Filter Door – "Filter" is stamped on the panel, and includes
Break/Seal and double wall construction to reduce two captive screws with easy grip knobs.
cabinet loss and sweating. 9 Insulation on Center Bar – Exclusive center bar insulation
3 1" Foil Faced Insulation – Thicker foil faced insulation for reduced cabinet loss, sweating and lower power bills.
for reduced cabinet loss, sweating and lower power bills. 0 Door Gasket – Exclusive formed gasket (similar to car door
4 Enclosed Control Box – Totally enclosed control box gasket) to reduce air infiltration and heat transfer and lower
with transformer inside to improve component life, unit power bills.
durability and reliability. q Air-TiteTM Circuit Breaker Door – Easy access to breakers
5 Corrosion Resistant Screws – Exclusive “WeatherguardTM” with positive air seal.
coated screws to maintain the quality appearance of the
unit for the life of the product. The SEER test for system efficiency places the air handler in
6 Coupling Panel Insulation – Exclusive “No Burn” refrigerant the ambient return air stream (80°F). If your air handler is to
coupling panel with thicker insulation for reduced heat loss. be in an unconditioned/severe climatic location, you should
consider the advantages of the “Air-TiteTM” model air handler.
7 Filter Door Seal – Improved door seal for reduced air infiltration,
For complete equipment / combination
Effective 1/1/06 AH-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons

• Enhanced Comfort-RTM dehumidification • Polarized plugs for making motor and


start-up transformer electrical connections from air
• Soft start - cycle-on speed is ramped up handler control box to electric heaters
gradually to reduce sound and draft • Primary and secondary drain connections
• 200/230 volt primary & 24 volt, 75 VA • Built-in indoor fan delay function for
secondary transformer increased efficiency
• R 4.2-1" foil face insulated cabinet • TWE air handlers are approved for modular
• Corrosion resistant galvanized metal with or manufactured homes.
attractive finish • Energy saving continuous fan
• Versatile duct flange - allows flush fit 3/4", • Enhanced cooling/heating control Air TiteTM
1", or 1.5" duct insulation • 031E airflow selectable for 1-1/2 – 3 ton
• Low voltage terminal board O.D. unit
• External brazed refrigerant connections • 037E airflow selectable for 2 – 3-1/2 ton
11/2 through 5 Tons • Filter panel stamped with word "filter" O.D. unit
TWE-E (R-22) & 4TEE (R-410A) • Filter door seal • 040E airflow selectable for 2 – 3-1/2 ton
Convertible Air Handlers • Exclusive duct flange thermal break/seal O.D. unit
• Ships for vertical upflow and horizontal right • Check valve for heat pump application • 049E airflow selectable for 3 – 5 ton O.D.
applications from factory • IAQ (Indoor Air Quality) sloped/free draining unit
• Six-way convertibility-horizontal (left & right); pan, no standing water • 065E airflow selectable for 3-1/2 – 5 ton
front & rear access; upflow, downflow • Non-bleed expansion valve refrigerant O.D. unit
• Electrical, refrigerant, condensate & blower control • 5 year limited parts residential warranty
access convertible to either side • Internally enhanced finned coil tubing • 1 year limited parts commercial warranty
• Compact 21" depth for easy installation • Access to heater circuit breakers pull/ • Optional extended warranties
• Variable speed Direct drive ECM motor disconnects
Table AH-3-A — R-22 Convertible, Variable Speed with Comfort-RTM Enhanced Mode Option (200/230/1/60)
Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5
TWE031E13FB 31,000 TXV-NB Variable 43x21.5x 21 134 19.22x12.02 or 18.22x 11.02 19.5x18.07 20x20x1 ¾ /16
TWE037E13FB 37,000 TXV-NB Variable 45x23.5x21 142 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3
/8
TWE040E13FB 40,000 TXV-NB Variable 51.75x26x21 174 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7/8 3
/8
TWE049E13FB 49,000 TXV-NB Variable 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
TWE065E13FB3 65,000 TXV-NB Variable 62.75x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8

Table AH-3-B — R-22 Convertible, Dual Circuit, Variable Speed with Comfort-RTM Enhanced Mode Option (200/230/1/60)
TWE062E13FB3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 ¾ 3
/8

Table AH-3-C —R-410A Variable Speed Air-Tite™ (200/230/1/60)


3 5
4TEE3F31A1000A 31,000 TXV-NB Variable 43x21.5x21 134 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 3
4TEE3F37A1000A 37,000 TXV-NB Variable 45x23.5x21 142 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /4 /8
3 3
4TEE3F40A1000A 40,000 TXV-NB Variable 51.75x26x21 174 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /4 /8
7 3
4TEE3F49A1000A 49,000 TXV-NB Variable 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
4TEE3F65A1000A3 65,000 TXV-NB Variable 62.75x26x21 218 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 7
/8 3
/8

Table AH-3-D —R-410A Convertible, Dual Circuit, Variable Speed with Comfort-R™ Enhanced Mode Option (200/230/1/60)
4TEE3F62A1000A3 65,000 TXV-NB(2) Variable 63x26x21 218 23.72x12.02 or 22.72x11.02 24x18.22 20x25x1 ¾ 3
/8

Table AH-3-E – Accessories


Model Number Description Used With
AY28X079 .................................... Evaporator Defrost Control Kit ...................... All Cooling Models
AY28X084 .................................... Evaporator Defrost Control Kit ...................... All Heat Pump Models
BAY99X1235 ............................... Knockout Cover Plate* ................................... TWE031E-065E, 4TEE3F31A-65A
BAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, 1419BRKB
TAYBASE100 ............................... Downflow Subbase ........................................ TWE037E, 4TEE3F37A
TAYBASE101 ............................... Downflow Subbase ........................................ TWE031E, 4TEE3F31A
TAYBASE102 ............................... Downflow Subbase ........................................ TWE040E-065E, 4TEE3F40A-65A
TAYPLNM1004 ........................... Pedestal Plenum Upflow ................................ TWE031E-037E, 4TEE3F31A-37A
TAYPLNM101 ............................... Pedestal Plenum Upflow ................................ TWE040E-065E, 4TEE3F40A-65A
1 Actual opening does not include flange. 4 4TEE3F31A-center on plenum for 2" difference in width.
2 Adjustable duct flange allows for a flush fit with 5 Minimum order 1 unit ( 1 unit = 50 pieces).
11/2 inch insulation or 3/4 inch or 1 inch insulation. * Required if no electric heat is used.
3 Two (2) piece cabinet
See Heater Tables on Pages AH-9
For complete equipment / combination
selections and installation instructions, please AH-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons

• 13.0 - 14.0 SEER • Versatile duct flange - allows flush fit 3/4",
• High Efficiency direct drive motor 1", or 1.5" duct insulation
• Ships for vertical upflow and horizontal right • Filter panel stamped with word "filter"
applications from factory • 200/230 volt primary & 24 volt secondary
• Six- way convertibility-horizontal (left & transformer
right) upflow, downflow • Low voltage wire nut connections
• “1-man” installation opportunity • Insulated cabinet
• Electrical, refrigerant, condensate & blower • External access to heater electrical
access convertible to either side disconnects
• Compact 21" depth for easy • Polarized plugs for making electrical
installation connections from air handler control box to
• Corrosion resistant galvanized metal with heaters
attractive finish • Approved for modular or manufactured
• Superior humidity performance homes
11/2 through 5 Tons
• Enhanced internally finned coil tubes • Optional extended warranties
Convertible High Efficiency
Air Handlers

Table AH-4-A — Horizontal with vertical convertibility (200/230/1/60)


Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
2TEH3F18A1000A 18,000 TXV-NB 4 43x21.5x 21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x 5/8 1
/4
2TEH3F24A1000A 24,000 TXV-NB 4 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5
/16
2TEH3F30A1000A 30,000 TXV-NB 4 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5
/16
2TEH3F36A1000A 36,000 TXV-NB 4 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3
/8
2TEH3F42A1000A 42,000 TXV-NB 4 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3
/8
2TEH3F48A1000A* 48,000 TXV-NB 4 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3
/8
2TEH3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 11/8 3
/8

Table AH-4-B – Accessories


Model Number Description Used With
AY28X079 ..................................... Evaporator Defrost Control Kit ........................ All Cooling Models
BAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1315BRKA, BAYHTR1319BRKA
TAYPLNM1001 ............................ Pedestal Plenum Upflow ................................ 2TEH3F18-60A1000A
TAYBASE101 ............................... Downflow Subbase ......................................... 2TEH3F18-36A1000A
TAYBASE100 ............................... Downflow Subbase ......................................... 2TEH3F42-60A1000A
1 For TEH018,024,030, center on plenum for 2" difference in width.
* Two piece cabinet
BAYHTR1300 ONLY
See Heater Tables on Pages AH-8

2TEH3F18 & 24B will accommodate 10 & 15 kW Strip Heat - (BAYHTR1300 series only) in March, 2006.

For complete equipment / combination


Effective 1/1/06 AH-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons

• 13.0 SEER • Versatile duct flange - allows flush fit 3/4",


• Ships for vertical upflow and horizontal right 1", or 1.5" duct insulation
applications from factory • Filter panel stamped with word "filter"
• Six- way convertibility-horizontal (left & • 200/230 volt primary & 24 volt secondary
right); front & rear access; upflow, transformer
downflow • Low voltage wire nut connections
• “1-man” installation opportunity • Insulated cabinet
• Electrical, refrigerant, condensate & blower • External access to heater electrical
access convertible to either side disconnects
• Compact 21" depth for easy • Polarized plugs for making electrical
installation connections from air handler control box to
• Corrosion resistant galvanized metal with heaters
attractive finish • Approved for modular or manufactured
• Superior humidity performance homes
11/2 through 5 Tons
• Enhanced internally finned coil tubes • Optional extended warranties
2/4TEC • Direct drive motor
Convertible Air Handlers
Table AH-5-A — Horizontal with vertical convertibility (200/230/1/60)
Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
2TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 5/8 1
/4
2TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5
/16
2TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 3/4 5
/16
2TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 7/8 3
/8
2TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 7/8 3
/8
2TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3
/8
2TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
2TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 11/8 3
/8

1 1
4TEC3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /2 /4
5 5
4TEC3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /16
3 5
4TEC3F30A1000A 30,000 TXV-NB 3 45x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 3
4TEC3F36A1000A 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /8
3 3
4TEC3F42A1000A 42,000 TXV-NB 3 51.8x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /4 /8
7 3
4TEC3F48A1000A* 48,000 TXV-NB 3 57.9x23.5x21 188 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /8 /8
7 3
4TEC3F55A1000A* 60,000 TXV-NB 3 57.9x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
7 3
4TEC3F60A1000A* 60,000 TXV-NB 4 57.9x23.5x21 193 21.22x12.02 or 20.22x11.02 21.5x18.07 20x22x1 /8 /8

Table AH-5-B – Accessories


Model Number Description Used With
BAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, BAYHTR1419BRKB
TAYPLNM1001 ............................ Pedestal Plenum Upflow ................................ 2/4TEC3F18-60A1000A
TAYBASE101 ............................... Downflow Subbase ......................................... 2/4TEC3F18-36A1000A
TAYBASE100 ............................... Downflow Subbase ......................................... 2/4TEC3F42-60A1000A
BAY99X123 .................................. Knockout Cover Plate ..................................... 2/4TEC3F18-60A1000A
1 For TEC018,024,030, center on plenum for 2" difference in width.
* Two piece cabinet
See Heater Tables on Pages AH-9

For complete equipment / combination


selections and installation instructions, please AH-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 4 Tons

• Exclusive easy to clean coil and drain pan • Durable, glass-filled composite - Never rust,
• Convertible upflow to horizontal left (no no leak drain pan
tools required) (matches installed units) • Maximum depth 21" - fits pull-down
• Designed to use "off the shelf" staircase
standard size replaceable fiberglass • Exclusive maximum width 23.5" - fits 2-ft.
filters wide door all sizes
• Easy to remove filters and blowers for easy • External access to electrical disconnects
cleaning and replacement • Direct drive motor
• Expanded application fit with narrow • Filter panel stamped with word "filter"
cabinet profile • Expansion valve (non-bleed TXV)
• Easy access electrical controls and hook- standard on all models
up • Polarized plugs for easy hook-up to electric
• Attractive enamel finish heaters
• R 4.2 - 1" insulation • 200/230 volt primary and 24 volt secondary
11/2 through 4 Tons • Versatile duct flange - allows flush fit with transformer
3/4", 1" or 1.5" duct insulation • Approved for modular or manufactured
• Air-Tite™ cabinet - low leak by design homes
• IAQ (Indoor Air Quality) sloped/free • Optional extended warranties
draining pan (no standing water)

Table AH-6-A — Vertical Upflow and Horizontal Left (200/230/1/60)


Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
2TGB3F18A1000A 18,000 TXV-NB 3 45.7x18x21 124 16x12.12 or 15x11.12 16x18.22 16x20x1 /8 /4
3 5
2TGB3F25A1000A 24,000 TXV-NB 3 45.7x18x21 124 16x12.12 or 15x11.12 16x18.22 16x20x1 /4 /16
3 5
2TGB3F30A1000A 30,000 TXV-NB 3 52x18x21 135 16x12.12 or 15x11.12 16x18.22 16x20x1 /4 /16
7 3
2TGB3F36A1000A 36,000 TXV-NB 3 52x18x21 135 16x12.12 or 15x11.12 16x18.22 16x20x1 /8 /8
7 3
2TGB3F42A1000A 42,000 TXV-NB 3 48.3x23.5x21 147 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 /8 /8
7 3
2TGB3F48A1000A 48,000 TXV-NB 3 57.3x23.5x21 172 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 /8 /8

Table AH-6-B – Accessories


Model Number Description Used With
BAYSPEK140B ............................. Single Power Entry Kit .................................... BAYHTR1415BRKB, BAYHTR1419BRKB
See Heater Tables on Pages AH-9

For complete equipment / combination


Effective 1/1/06 AH-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 2½ Tons

• Shipped in vertical upflow, bottom return • Filter rack with throw away filter
with front access & convertible to vertical • Easy access electrical controls and
upflow front return hook-up
• Variable speed ECM motor • 200/230 volt primary and 24 volt secondary
(2/4TFE Models) transformer
• Enhanced Comfort-R™ (2/4TFE Models) • Multi-speed blower (2TFB Models)
• Soft start - fan speed is ramped up • Direct drive motor (2TFB Models)
gradually to reduce sound and draft • Factory installed electric heaters
(2/4TFE Models) • Factory installed service disconnect
• Low voltage terminal board • Internally enhanced finned coil tubing
(2/4TFE Models) • Primary and secondary drain connections
• Air-Tite™ cabinet - low leakage by design • Approved for modular or manufactured
• Attractive enamel finish homes
• R 4.2-1” insulation • Optional extended warranties
• Exclusive easy clean coil and drain pan • Five year limited parts warranty
• Easy to remove filters and blowers for easy
11/2 through 21/2 Tons cleaning and replacement

Table AH-7-A — Vertical Upflow and Horizontal Left (200/230/1/60)


Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
2TFB3F18B1D05A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 /8 /4
5 1
2TFB3F18B1D08A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 /8 /4
5 1
2TFB3F18B1D10A 18,000 TXV-NB 2 37x22x19.4 115 14x10.12 17.22x20 18x20x1 /8 /4
3 5
2TFB3F24B1D05A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFB3F24B1D08A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFB3F24B1D10A 24,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFB3F30B1D05A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFB3F30B1D08A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFB3F30B1D10A 30,000 TXV-NB 2 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16

Table AH-7-B — Variable Speed R-22 (200/230/1/60)


Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
3 5
2TFE3F25B1D05A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFE3F25B1D08A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16
3 5
2TFE3F25B1D10A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /4 /16

Table AH-7-C — Variable Speed R-410A (200/230/1/60)


Cooling
Unit Capacity Metering Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) Device Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
4TFE3F25B1D05A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /8 /4
5 1
4TFE3F25B1D08A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /8 /4
5 1
4TFE3F25B1D10A 25,000 TXV-NB Var 39x22x19.4 120 14x10.12 17.22x20 18x20x1 /8 /4
* Heater kW is based on 240 volt rating.

For complete equipment / combination


selections and installation instructions, please AH-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Heaters for Split System and
Convertible Air Handlers

Table AH-8-A Heaters for 2TEH only


Heater Capacity Capacity Heater Amps Contains
Model @ 240 Volts @ 208 Volts Rated Control per Circuit Circuit
Number kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt Breakers
BAYHTR1305000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 No
BAYHTR1305BRK 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 Yes
BAYHTR1305PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 No
BAYHTR1308000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 No
BAYHTR1308BRK 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 Yes
BAYHTR1308PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 No
BAYHTR1310000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 No
BAYHTR1310BRK 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 Yes
BAYHTR1310PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 No
BAYHTR1315BRK 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 Yes
BAYHTR1319BRK 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 Yes
Three Phase
BAYHTR3310000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 No
BAYHTR3315000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No
1 Circuit 1/Circuit 2
2 Heater can be converted to single circuit power entry by using
BAYSPEK140B. This kit allows a single power circuit to be used with electric
heaters that contain two (2) circuit breakers.

Table AH-9-B Heater Matrix for 2TEH only


MINIMUM HEATING AIRFLOW CFM - HEATER MATRIX
HEATER MODEL NUMBER
AIR HANDLER
MODEL NUMBER BAYHTR1305+++ BAYHTR1308+++ BAYHTR1310+++ BAYHTR3310000 BAYHTR1315BRK BAYHTR3315000 BAYHTR1319BRK
4.80kW 7.68kW 9.60kW 9.60kW 15.36kW 15.36kW 19.20kW
NUMBER OF 1 2 2 2 3 3 4
HEATER RACKS
NUMBER OF 1 1 1 1 2 1 2
CIRCUITS
2TEH3F18A100A L/MH L/MH N/A N/A N/A N/A N/A
2TEH3F24A100A L/ML L/PS N/A N/A N/A N/A N/A
2TEH3F30A100A L/L L/ML ML/H ML/H N/A N/A N/A
2TEH3F36A100A L/L L/PS ML/PS ML/PS ML/H ML/H ML/H
2TEH3F42A100A ML/ML ML/PS ML/MH ML/MH ML/H ML/H ML/H
2TEH3F48A100A ML/ML ML/ML ML/PS ML/PS ML/H ML/H ML/H
2TEH3F60A100A ML/ML ML/ML ML/ML ML/ML ML/MH ML/MH ML/H

Cooling/Heat Pump Air Flow


PS = Position sensitive. Minimum speed tap varies based on air handler installation position. See air handler nameplate or product data.
L = Low
ML = Medium-Low
MH = Medium-High
H = High
+++ = 000 (pigtails), PCD (contains pull disconnect), BRK (contains circuit disconnects)

BAYSPEK140B to be used with BAYHTR1315BRKA, BAYHTR1319BRKA.


CAUTION: Any power supply and/or combination power supply, circuit or circuits must be
wired and protected in accordance with local electrical codes.

For complete equipment / combination


Effective 1/1/06 AH-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Heaters for Split System and
Convertible Air Handlers

Table AH-9-B Heaters For TWE-C/D; TWE-P;TWE-E;TWG; 4TEE;2/4TEP, 2/4 TEC, 2TGB
Heater Capacity Capacity Heater Amps Contains
Model @ 240 Volts @ 208 Volts Rated Control per Circuit Circuit
Number kW BTUH kW BTUH Voltage Stages 208 Volts 240Volt Breakers
BAYHTR1405000 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 No
BAYHTR1405BRKB 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 Yes
BAYHTR1405PDC 4.80 16,400 3.6 12,300 208/240/1/60 1 17.3 20 No
BAYHTR1408000 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 No
BAYHTR1408BRKB 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 Yes
BAYHTR1408PDC 7.68 26,200 5.76 19,700 208/240/1/60 1 27.7 32 No
BAYHTR1410000 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 No
BAYHTR1410BRKB 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 Yes
BAYHTR1410PDC 9.60 32,800 7.20 24,600 208/240/1/60 1 34.6 40 No
BAYHTR1415BRKB 15.36 52,400 11.53 39,300 208/240/1/60 2 34.6/20.812 40/241 Yes
BAYHTR1419BRKB 19.20 65,500 14.42 44,200 208/240/1/60 2 27.8/41.612 32/481 Yes
BAYHTR1425BRKB 24.96 85,200 18.73 63,900 208/240/1/60 3 38.1/34.6/17.31 44/40/201 Yes
Three Phase
BAYHTR3410000 9.60 32,800 7.20 24,600 208/240/3/60 1 30 34.6 No
BAYHTR3415000 15.36 52,400 11.53 39,300 208/240/3/60 1 33 38.2 No

MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX
AIR HEATER MODEL NUMBER BAYHTR—
HANDLER
MODEL 1405 000 1408 000 1410 000
BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRK
NUMBER PDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW
4.80kW 7.68kW 3410 000
9.60kW
NUMBER OF 1 2 2 2 2 4 5
HEATER RACKS
NUMBER OF 1 1 1 2 1 2 3
CIRCUITS
TWE031E 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —
TWE037E 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —
TWE040E 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400
TWE049E 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600
TWE062E 900/1500 900/1500 900/1500 1200/1800 1200/1800 1200/1800 1200/1800
TWE065E 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/1800
4TEE3F31A 700/1000 700/1000 700/1000 700/1125 700/1125 1000/1350 —
4TEE3F37A 600/700 600/900 600/900 1000/1300 1000/1300 1000/1350 —
4TEE3F40A 600/1100 600/1100 600/1100 1100/1400 1100/1400 1100/1400 1100/1400
4TEE3F49A 700/1400 700/1400 700/1400 1400/1600 1400/1600 1400/1600 1400/1600
4TEE3F65A 900/1500* 900/1500* 900/1500* 1200/1800 1200/1800 1200/1800 1200/1800
2/4TEC3F18A L/L L/M L/M — — — —
2/4TEC3F24A L/L L/L L/L L/M L/M — —
2/4TEC3F30A L/L L/L L/L L/M L/M — —
2/4TEC3F36A L/L L/L L/L L/H L/H L/H —
(Example: L=Low, M=Medium, H=High Speed) 2/4TEC3F42A L/L L/L L/L L/PS L/PS L/H —
PS = Minimum speed tap varies based on air 2/4TEC3F48A L/L L/L L/L L/PS L/PS L/PS —
handler installation position.
AS = Heater application is affected based on
2/4TEC3F60A L/L L/L L/L L/PS L/PS L/PS —
whether the outdoor unit is a heat pump 2TGB3F18A L/L L/M L/H N/A N/A N/A —
or cooling unit.
000 = Pigtails, BRK = Contains circuit
2TGB3F25A L/L L/M L/M L/H L/H N/A —
breakers, PDC = Contains Pull 2TGB3F30A L/L L/L L/L L/M L/M N/A —
Disconnect 2TGB3F36A L/L L/L L/L L/M L/M N/A —
* For heat pump applications, upflow position 2TGB3F42A L/L L/L L/L L/H L/H N/A
only minimum setting is 1200 2TGB3F48A L/L L/L L/L L/H L/H L/H —
1 Circuit 1/Circuit 2
2 Heater can be converted to single circuit power entry by using BAYSPEK140B. This kit allows a single power circuit to be
used with electric heaters that contain two (2) circuit breakers.
BAYSPEK140B to be used with BAYHTR1415BRKB/ BAYHTR1419BRKB only.
CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local
electrical codes.
For complete equipment / combination
selections and installation instructions, please AH-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Heaters for Split System and
Convertible Air Handlers

MINIMUM HEATING AIRFLOW CFM COOLING/HEAT PUMP AIR FLOW - HEATER MATRIX
AIR HEATER MODEL NUMBER BAYHTR—
HANDLER
MODEL 1405 000 1408 000 1410 000
BRK BRK BRK 1415 BRK 3415 000 1419 BRK 1425 BRK
NUMBER PDC PDC PDC 15.36kW 15.36kW 19.20kW 24.96kW
4.80kW 7.68kW 3410 000
9.60kW
NUMBER OF 1 2 2 2 2 4 5
HEATER RACKS
NUMBER OF 1 1 1 2 1 2 3
CIRCUITS
TWE018P L/L L/M L/M — — — —
TWE024P L/L L/L L/L L/M L/M — —
TWE030P L/L L/L L/L L/M L/M — —
TWE036P L/L L/L L/L L/H L/H L/H —
TWE042P
TWE048P
TWE060P
PHASED OUT
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
PS
PS
PS
PS
PS
PS
L/H
L/H
L/H

L/H
L/H
TWE063P L/L L/L L/L PS PS L/H L/H
2TEP3F48B — L/L L/L L/L L/L — —
2TEP3F63B — L/L L/L PS PS — —
4TEP3F18A L/L L/M L/M — — — —
4TEP3F24A L/L L/L L/L L/M L/M — —
4TEP3F30A L/L L/L L/L L/M L/M — —
4TEP3F36A L/L L/L L/L L/H L/H L/H —
4TEP3F42A
4TEP3F48A
4TEP3F63A
PHASED OUT
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
PS
PS
PS
PS
PS
PS
L/H
L/H
L/H

L/H
L/H
4TEP3F48B — L/L L/L L/L L/L — —
4TEP3F63B — L/L L/L L/L L/L — —
TWE018C L/L L/M L/M — — — —
TWE024C L/L L/L L/L L/M L/M — —
TWE030C L/L L/L L/L L/M L/M — —
TWE036C L/L L/L L/L L/L L/L PS —
TWE042C
TWE048C
TWE060C/D
L/L
L/L
AS
PHASED OUT L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
L/L
AS
L/H
L/H

L/H
L/H
(Example: L=Low, M=Medium, H=High Speed)
PS = Minimum speed tap varies based on air TWG018A L/L L/M L/H — — — —
handler installation position. TWG025A L/L L/M L/M L/H L/H — —
AS = Heater application is affected based on TWG030A L/L L/L L/L L/M L/M — —

PHASED OUT
whether the outdoor unit is a heat pump
or cooling unit. TWG036/037A L/L L/L L/L L/M L/M — —
000 = Pigtails, BRK = Contains circuit TWG042A L/L L/L L/L L/H L/H — —
breakers, PDC = Contains Pull TWG048A L/L L/L L/L L/H L/H L/M —
Disconnect
* For heat pump applications, upflow position
TWG060A L/L L/L L/L L/L L/L L/M L/H
only minimum setting is 1200 CAUTION: Any power supply and/or combination power supply, circuit or circuits must be wired and protected in accordance with local
electrical codes.

For complete equipment / combination


Effective 1/1/06 AH-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons

• 12.0 SEER • Enhanced internally finned coil tubes


• Ships horizontal - converts to upflow by • Direct drive motor
standing unit on end • IAQ (Indoor Air Quality) sloped/free draining
• Six-way convertibility-horizontal (left & pan, no standing water
right);front & rear access; upflow, downflow • Versatile duct flange - allows flush fit 3/4", 1",
• "1- man" installation opportunity 1.5" duct insulation
• Electrical, refrigerant, condensate & blower • Exclusive duct flange thermal break/seal
access convertible to either side • External access to heater circuit breakers pull/
• Compact 21" depth for easy installation disconnects
• Multi-speed blower • Polarized plugs for making electrical
• Filter panel stamped with word "filter" connections from air handler control box to
• 200/230 volt primary & 24 volt secondary heaters
transformer • Non-bleed expansion valve refrigerant control
11/2 through 5 Tons • Low voltage wire nut connections • Approved for modular or manufactured homes
TWE-P (R-22) & 4TEP (R-410A) • R 4.2-1" foil face insulated cabinet • 1-year limited parts warranty
• Corrosion resistant galvanized metal with • 5 year limited parts residential warranty
Convertible Air Handlers attractive finish • 1 year limited parts commercial warranty
• Superior condensate performance • Optional extended warranties
Table AH-11-A — R-22 Convertible (200/230/1/60)
Cooling
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
TWE018P130B 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /4
5 1
TWE018P13FB (Air TiteTM) 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /4
3 5
TWE024P130B 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 5
TWE024P13FB(Air TiteTM) 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 5
TWE030P130B 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 5
TWE030P13FB(Air TiteTM) 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
7 3
TWE036P130B 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /8
7 3
TWE036P13FB(Air TiteTM) 36,000 TXV-NB 3 45x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /8
TWE042P130B
TWE042P13FB(Air TiteTM)
TWE048P130B
TWE048P13FB(Air TiteTM)
TWE060P130B
PHASED OUT
42,000
42,000
48,000
48,000
58,000
TXV-NB
TXV-NB
TXV-NB
TXV-NB
TXV-NB
3
3
3
3
3
51.75x23.5x 21
51.75x23.5x 21
57.90x26x21
57.90x26x21
57.90x26x21
165
165
188
188
193
21.22x12.02 or 20.22x11.02
21.22x12.02 or 20.22x11.02
23.72x12.02 or 22.72x11.02
23.72x12.02 or 22.72x11.02
23.72x12.02 or 22.72x11.02
21.5x18.07
21.5x18.07
24x18.07
24x18.07
24x18.07
20x20x1
20x20x1
20x25x1
20x25x1
20x25x1
7

7
/8
/8
11/8
11/8
11/8
3

3
/8
/8
/8
/8
/8
TWE060P13FB(Air TiteTM) 58,000 TXV-NB 3 57.90x26x21 193 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
TWE063P130B3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
TWE063P13FB3(Air TiteTM) 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 11/8 3
/8
2TEP3F48B1000B3(Air TiteTM) 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3
/8
2TEP3F63B1000B3(Air TiteTM) 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3
/8

Table AH-11-B —R-410A Air-Tite™ (200/230/1/60)


1 1
4TEP3F18A1000A 18,000 TXV-NB 3 43x21.5x21 114 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /2 /4
5 5
4TEP3F24A1000A 24,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /16

PHASED OUT
3 5
4TEP3F30A1000A 30,000 TXV-NB 3 43x21.5x21 121 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 3
4TEP3F36A1000A 36,000 TXV-NB 3 45 x21.5x21 135 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /8
3 3
4TEP3F42A1000A 42,000 TXV-NB 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 /4 /8
7 3
4TEP3F48A1000A 48,000 TXV-NB 3 57.90x26x21 188 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
7 3
4TEP3F63A1000A3 60,000 TXV-NB 3 62.75x26x21 211 23.72x12.02 or 22.72x11.02 24x18.07 20x25x1 /8 /8
7 3
4TEP3F48B1000B3 48,000 TXV-NB 3 57.90x23.5x21 166 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 /8 /8
7 3
4TEP3F63B1000B3 60,000 TXV-NB 3 57.90x23.5x21 170 21.22x12.02 or 20.22x11.02 21.5x18.07 20x25x1 /8 /8

Table AH-11-C – Accessories


Model Number Description Used With
BAY24X038 .................................. Plug-In Speed Change Relay Kit ................... TWE018-063P/2, 4TEP3F18-063P
BAY99X1234 ............................... Knockout Cover Plate** ................................. TWE018-063P/2, 4TEP3F18-063P

PHASED OUT
BAYSPEK140A ............................ Single Power Entry Kit ................................... BAYHTR1415BRKAB, 1419BRKAB
TAYBASE100 ............................... Downflow Subbase ........................................ TWE042P/4TEP3F42P
TAYBASE101 ............................... Downflow Subbase ........................................ TWE018-36P/4TEP3F18-36P
TAYBASE102 ............................... Downflow Subbase ........................................ TWE048P-063P/2, 4TEP3F48-F63P
TAYPLNM1005 ............................ Pedestal Plenum Upflow ................................ TWE018-042P/2, 4TEP3F48-F42P
TAYPLNM101 ............................... Pedestal Plenum Upflow ................................ TWE048-063P/2, 4TEP3F48-F63P
1 Actual opening does not include flange.
4 Minimum Order 1 unit (1 unit = 50 pcs.)
2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.
5 For TWE018P-36P, 4TEP3F18A-36A, center on plenum for 2" difference in width.
3 Two piece cabinet.
** Required if no electric heat is used.
See Heater Tables on Pages AH-9
For complete equipment / combination
selections and installation instructions, please AH-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons

• Ships horizontal - converts to upflow by • Enhanced internally finned coil tubes


standing unit on end. • Direct drive motor
• Six-way convertibility-horizontal (left & • Standard size filters
right); front & rear access; upflow, downflow • Multi-speed blower
• "1-man" installation opportunity • 200/230 volt primary & 24 volt secondary
• Electrical, refrigerant, condensate & blower transformer
access convertible to either side • Low voltage wire nut connections
• Versatile duct flange - allows flush fit 3/4", • R 4.2-1" foil face insulated cabinet
1", or 1.5" duct insulation • External access to heater circuit breakers
• Compact 21" depth for easy installation • Polarized plugs for making electrical
• Uses BAYHTR1400 series heaters connections from air handler control box to
• Corrosion resistant galvanized metal with heaters
attractive finish • Built-in indoor fan delay function for
1½ through 5 Tons • IAQ (Indoor Air Quality) sloped/free draining increased efficiency. No kit required.
pan, no standing water • Motors internally isolated
TWE-C/D • Approved for modular or manufactured • 5 year limited parts residential warranty
Convertible Air Handlers homes • 1 year limited parts commercial warranty
• Superior condensate performance • Optional extended warranties
Table AH-12-A — Convertible (200/230/1/60)
Cooling
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
TWE018C140B 18,000 .049 3 43x21.5x21 113 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /4
5 1
TWE018C14FB (Air TiteTM) 18,000 .049 3 43x21.5x21 113 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /8 /4
3 5
TWE024C140B 24,000 .057 3 43x21.5x21 115 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 5
TWE024C14FB (Air TiteTM) 24,000 .057 3 43x21.5x21 115 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 5
TWE030C140B 30,000 .069 3 43x21.5x21 120 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
3 5
TWE030C14FB(Air TiteTM) 30,000 .069 3 43x21.5x21 120 19.22x12.02 or 18.22x11.02 19.5x18.07 20x20x1 /4 /16
TWE036C140B
TWE036C14FB(Air TiteTM)
TWE042C140C
TWE042C14FC(Air TiteTM)
TWE048C140C
PHASED OUT
36,000
36,000
42,000
42,000
48,000
.069
.069
.077
.077
.083
3
3
3
3
3
43x21.5x21
43x21.5x21
45x23.5x21
45x23.5x21
51.75x23.5x21
125
125
145
145
165
19.22x12.02 or 18.22x11.02
19.22x12.02 or 18.22x11.02
21.22x12.02 or 20.22x11.02
21.22x12.02 or 20.22x11.02
21.22x12.02 or 20.22x11.02
19.5x18.07
19.5x18.07
21.5x18.07
21.5x18.07
21.5x18.07
20x20x1
20x20x1
20x20x1
20x20x1
20x20x1
7

7
/8
/8
/8
/8
11/8
3

3
/8
/8
/8
/8
/8
TWE048C14FC(Air TiteTM) 48,000 .083 3 51.75x23.5x21 165 21.22x12.02 or 20.22x11.02 21.5x18.07 20x20x1 11/8 3
/8
TWE060D150B 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3
/8
TWE060C15FD3(Air TiteTM) 60,000 TXV-B 3 57.90x23.5 x21 185 21.22x12.02 or 20.22x11.02 21.5x18.07 22x20x1 11/8 3
/8

Table AH-12-B – Accessories


Model Number Description Used With
AY28X079 ...................................... Evap. Defrost Control Kit ................................. (All Cooling Models)
AY28X084 ...................................... Evap. Defrost Control Kit ................................. (All Heat Pump Models)
BAY24X038 .................................... Plug-in Speed Change Relay Kit ..................... TWE018-060C/D

PHASED OUT
BAY99X1235 ................................. Knockout Cover Plate* .................................... TWE018-060C/D
BAYSPEK140A .............................. Single Power Entry Kit .................................... BAYHTR1415BRKAB, 1419BRKAB
TAYBASE100 ................................. Downflow Subbase ......................................... TWE042-060C/D
TAYBASE101 ................................. Downflow Subbase ......................................... TWE018-036C
TAYPLNM1004 ............................. Pedestal Plenum Upflow ................................. TWE018-060C/D
1 Actual opening does not include flange.
2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.
3 Two piece cabinet.
4 For TWE018-036 center on plenum for 2" difference in width.
5 Minimum order 1 unit (1 unit = 50 pcs.).
* Required if no electric heat is used.
See Heater Tables on Pages AH-9

For complete equipment / combination


Effective 1/1/06 AH-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 5 Tons

• Easy to clean coil and drain pan • Exclusive maximum width 231/2 inches – fits
• Convertible upflow to horizontal left, (no 2 foot wide door
tools required) (matches installed units) • Built-in time delay
• Designed to use “off the shelf” standard • Full line 11/2 – 5 tons
size replaceable fiberglass filters – • Direct drive motor
Industry Exclusive • Filter panel stamped with word “filter”
• Easy to remove filters and blowers for easy • AccuTronTM refrigerant control
cleaning and replacement • Expansion valve (Bleed TXV) standard on
• Expanded application fit with narrow 5-ton models
cabinet profile • Polarized plugs for easy hook-up to electric
• Easy access electrical controls and heaters
hook-up • 200/230 volt primary and 24 volt secondary
• Attractive enamel finish transformer
• R 4.2-1" foil face insulated cabinet • Electric heaters with breaker option on all
• Versatile duct flange – allows flush fit 3/4, 1 sizes
or 11/2 inch duct insulation • Approved for modular or manufactured
• Tight cabinet - low leak by design homes
• IAQ (Indoor Air Quality) sloped/free draining • 5 year limited parts residential warranty
pan, no standing water • 1 year limited parts commercial warranty
11/2 through 5 Tons • Durable, glass-filled Lexan – Never rust, no • Optional extended warranties
TWG leak drain pan
Convertible Air Handlers • Maximum depth 21 inches – fits pull-down
staircase
Table AH-13-A — Convertible (208-230/1/60)
Cooling
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
TWG018A140B 18,000 .049 3 43x16x21 108 14x12.12 or 13x11.12 14x18.22 14x20x1 /8 /4
3 5
TWG025A140B 24,000 .057 3 45.70x18x21 124 16x12.12 or 15 x11.12 16x18.22 16x20x1 /4 /16

PHASED OUT
3 5
TWG030A140B 30,000 .067 3 45.70x18x21 125 16x12.12 or 15 x11.12 16x18.22 16x20x1 /4 /16
7 3
TWG036A140B 36,000 .067 3 52x18x21 135 16x12.12 or 15 x11.12 16x18.22 16x20x1 /8 /8
7 3
TWG037A140B 37,000 .067 3 43x21.5x21 145 19.5x12.12 or 18.5 x11.12 19.5x18.22 20x20x1 /8 /8
7 3
TWG042A140B 42,000 .075 3 43x23.5x21 160 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 /8 /8
7 3
TWG048A140B 48,000 .083 3 48.25x23.5x21 185 21.5x12.12 or 20.5x11.12 21.5x18.22 20x20x1 /8 /8
7 3
TWG060A150B 58,000 TXV-B 3 57.25x23.5x21 205 21.5x12.12 or 20.5x11.12 21.5x18.22 22x20x1 /8 /8
1 Actual opening does not include flange.
2 Adjustable duct flange allows for a flush fit with 3/4, 1 or 11/2 inch insulation.

See Heater Tables on Pages AH-9

For complete equipment / combination


selections and installation instructions, please AH-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase — 1½ through 3 Tons

• Shipped in vertical upflow front return with • AccuTronTM refrigerant control (2TFB)
front access & convertible to vertical upflow • Standard expansion valve kits are internally
bottom return mounted (2TFB)
• Tight cabinet - low leakage by design • Factory installed service disconnect
• Attractive enamel finish • Internally enhanced finned coil tubing
• R 4.2 – 1” insulation • Primary and secondary drain connections
• Exclusive easy clean coil and drain pan • Approved for modular or manufactured
• Easy to remove filters and blowers for easy homes
cleaning and replacement • Variable speed ECM motor (2TFE)
• Filter rack with throw away filter • Enhanced Comfort-RTM (2TFE)
• Easy access electrical controls and hook – • Soft start – cycle-on speed is ramped up
up 200/230 volt primary and 24 volt gradually to reduce sound (2TFE)
secondary transformer • Low voltage terminal board (2TFE)
• Built-in indoor fan delay function for • Expansion valve refrigerant control (2TFE)
increased efficiency. No kit required • 5 year limited parts residential warranty
• Multi-speed blower (2TFB) • 1 year limited parts commercial warranty
• Direct drive motor (2TFB) • Optional extended warranties
11/2 through 3 Tons
• Factory installed electric heaters
Table AH-14-A — (200/230/1/60)
Cooling Bottom
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
5 1
2TFB4018A1D05A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /8 /4
5 1
2TFB4018A1D08A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /8 /4
5 1
2TFB4018A1D10A 18,000 .049 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /8 /4
3 5
2TFB4024A1D05A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16

PHASED OUT
3 5
2TFB4024A1D08A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4024A1D10A 24,000 .057 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4030A1D05A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4030A1D08A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
3 5
2TFB4030A1D10A 30,000 .067 2 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
7 3
2TFB4036A1D05A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 /8 /8
7 3
2TFB4036A1D08A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 /8 /8
7 3
2TFB4036A1D10A 30,000 .067 2 39x22x19.4 120 14 x 10.12 17.22 x 20 18x20x1 /8 /8

Table AH-14-B — (200/230/1/60)


Cooling Bottom
Unit Capacity Fan Dimensions (in.) Shipping Supply Return Filter Line Size
Model No. (Btuh) FCCV Speed H xW x D Weight (Ibs.) 12
Opening12 1
Opening1 Sizes Gas Liquid
3 5
2TFE3025A1D05A 25,000 TXV-NB Var. 37x22x19.4 115 14 x 10.12 17.22 x 20 18x20x1 /4 /16
2TFE3025A1D08A
2TFE3025A1D10A
25,000
25,000
TXV-NB
TXV-NB
1 Actual opening does not include flange.
PHASED OUT
Var.
Var.
37x22x19.4
37x22x19.4
115
115
14 x 10.12
14 x 10.12
17.22 x 20
17.22 x 20
18x20x1
18x20x1
3

3
/4
/4
5

5
/16
/16

2 Adjustable duct flange allows for a flush fit with 11/2 inch insulation or 3/4 inch or 1 inch insulation.

For complete equipment / combination


Effective 1/1/06 AH-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase – 5 through 10 Tons
Three Phase – 5 through 20 Tons

• New 11th Digit "E" model ReliaTel™ and • IAQ (Indoor Air Quality) sloped/free draining
electromechancial compatible. pan, no standing water
• Upflow convertible to horizontal 5 • Two inch filters factory installed on 15, 20
• Expansion valve factory installed ton units
• Check valves for heat pump applications • Supplemental heaters (electric, water,
• Belt drive blower steam) fits directly on unit discharge for low
• Factory installed motor, belt, sheaves, installation cost
contactor, low voltage terminal board • Single point power entry for reduced
• One inch filters on 5 to 10 ton units (rack electrical power installation cost
convertible for field supplied two inch) • Unit fully assembled to reduce field
• Captive screws remain on the panels installation costs
for service ease • Compact design with low service clearance
• Low voltage terminal board to reduce building requirements
5, 71/2, 10, 15, 20 Ton TWE • Drain Pan • Brazed refrigerant piping connections
• Factory Installed (EDC) Evaporator Defrost • Fan relay UL listed and CSA Certified
Convertible Air Handlers Control • Optional extended warranties
(Upflow or Horizontal Only)
Table AH-15-A — Single Circuit Coil
Shipping Max Fuse Size
Unit Power Supply Capacity Drive 4
Dimensions (in.)4 Weight or Max Circuit
Tons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* 3*
Breaker3
Single Phase
5 TWE060A100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 15
71/2 TWE090A100E1 208-230/1/60 90,000 TXV Belt 54 x48 x 26 388 8 15
10 TWE120A100E1 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15
Three Phase
5 TWE060A300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 15
5 TWE060A400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 15
5 TWE060AW00E 575/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 15
71/2 TWE090A300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 15
71/2 TWE090AW00E1 575/3/60 90,000 TXV Belt 54 x48 x 23 298 4 15
10 TWE120A300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 15
10 TWE120AW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 15

Table AH-15-B— Dual Circuit Coil


Shipping Max Fuse Size
Unit Power Supply Capacity Drive 4
Dimensions (in.)4 Weight or Max Circuit
Tons Model No. Volts/Phase/Hz (Btuh) FCCV Type H x W x D (Ibs.) MCA* 3*
Breaker3
Single Phase
5 TWE060B100E 208-230/1/60 60,000 TXV Belt 48 x 39 x 23 298 7 15
71/2 TWE090B100E 208-230/1/60 90,000 TXV Belt 54 x 48 x 26 388 8 15
10 TWE120B100E 208-230/1/60 120,000 TXV Belt 54 x 64 x 26 439 11 15
Three Phase
5 TWE060B300E 208-230/3/60 60,000 TXV Belt 48 x 39 x 23 298 4 15
5 TWE060B400E 460/3/60 60,000 TXV Belt 48 x 39 x 23 298 2 15
71/2 TWE090B300E12 208-230/3/60 90,000 TXV Belt 54 x 48 x 26 388 7 15
10 TWE120B300E12 208-230/3/60 120,000 TXV Belt 54 x 64 x 26 439 8 15
10 TWE120BW00E1 575/3/60 120,000 TXV Belt 54 x 64 x 26 439 4 15
15 TWE180B300E 208-230/3/60 180,000 TXV Belt 69 x 80 x 28 754 12 20
15 TWE180B400E 460/3/60 180,000 TXV Belt 69 x 80 x 28 754 6 15
15 TWE180BW00E 575/3/60 180,000 TXV Belt 69 x 80 x 28 754 5 15
20 TWE240B300E 208-230/3/60 240,000 TXV Belt 72 x 93 x 30 886 19 30
20 TWE240B400E 460/3/60 240,000 TXV Belt 72 x 93 x 30 886 9 15
20 TWE240BW00E 575/3/60 240,000 TXV Belt 72 x 93 x 30 886 7 15
1 Control transformer not included. Order control transformer accessory when matching these air handlers with 4-6 ton condensing units.
2 Ships wired for 208-230/3/60. Field convertible to 460/3/60.
3 HACR type circuit breaker per NEC.
4 Dimensions based on Upflow position.
5 All air handlers are shipped with the drain pan installed in the horizontal position. If an alternate position is required, the drain pan should be repositioned before
setting the air handler.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please AH-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Single Phase – 5 through 10 Tons
Three Phase – 5 through 20 Tons

1
Table AH-16-A — Supplementary Heaters1
Model No. Power Supply kW Rating Used With
BAYHTRL106A 208/240/1/60 4.33/5.76 TWE060-120A1, TWE060-120B1
BAYHTRL112A 208/240/1/60 8.65/11.52 TWE060-120A1, TWE060-120B1
BAYHTRL117A 208/240/1/60 12.98/17.28 TWE060-120A1, TWE060-120B1
BAYHTRL123A 208/240/1/60 17.30/23.04 TWE060-120A1, TWE060-120B1
BAYHTRL129A 208/240/1/60 21.65/28.80 TWE090-120A1, TWE090-120B1
BAYHTRL305A 208/240/3/60 3.75/5.00 TWE060-120A3, TWE060-120B3
BAYHTRL310A 208/240/3/60 7.45/9.96 TWE060-120A3, TWE060-120B3
BAYHTRL315A 208/240/3/60 11.25/14.96 TWE060-120A3, TWE060-120B3
BAYHTRL325A 208/240/3/60 18.71/24.92 TWE060-120A3, TWE060-120B3
BAYHTRL335A 208/240/3/60 26.20/34.88 TWE090-120A3, TWE090-120B3
BAYHTRL405A 460/3/60 5.00 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL410A 460/3/60 9.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL415A 460/3/60 14.96 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL425A 460/3/60 24.92 TWE060A4,B4, TWE090-120A32, TWE090-120B32
BAYHTRL435A 460/3/60 34.88 TWE090,120A32, TWE090-120B32
BAYHTRLW05A 575/3/60 5.00 TWE060AW, TWE090-120AW, TWE090-120BW
BAYHTRLW10A 575/3/60 9.96 TWE060AW, TWE090-120AW, TWE090-120BW
BAYHTRLW15A 575/3/60 14.96 TWE060AW, TWE090-120AW, TWE090-120BW
BAYHTRLW25A 575/3/60 24.92 TWE060-120AW
BAYHTRLW35A 575/3/60 34.88 TWE090,120AW
BAYHTRM310A 208/230/3/60 7.50/10.00 TWE180-240B3
BAYHTRM320A 208/230/3/60 14.96/19.92 TWE180-240B3
BAYHTRM330A 208/230/3/60 22.50/29.92 TWE180-240B3
BAYHTRM350A 208/230/3/60 37.42/49.84 TWE180-240B3
BAYHTRM410A 460/3/60 10.00 TWE180-240B4
BAYHTRM420A 460/3/60 19.92 TWE180-240B4
BAYHTRM430A 460/3/60 29.92 TWE180-240B4
BAYHTRM450A 460/3/60 49.84 TWE180-240B4
BAYHTRMW10A 575/3/60 10.00 TWE180-240BW
BAYHTRMW20A 575/3/60 19.92 TWE180-240BW
BAYHTRMW30A 575/3/60 29.92 TWE180-240BW
BAYHTRMW50A 575/3/60 49.84 TWE180-240BW
1 Air Handler with heater of same voltage is single circuit single point.
2 Field converted to 460/3/60.

For complete equipment / combination


Effective 1/1/06 AH-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System Air Handlers
Accessories – 5 through 20 Tons
Table AH-17-A – Accessories
Model Number Description Used With
BAYBASE001A1 ............. Subbase (38 W x 22 L) .............................................................................................. TWE060A, TWE060B
BAYBASE002A1 ............. Subbase (471/2 W x 25 L) .......................................................................................... TWE090A, TWE090B
BAYBASE003A1 ............. Subbase (631/2 W x 25 L) .......................................................................................... TWE120A, TWE120B
BAYBASE004A1 ............. Subbase (791/2 W x 275/8 L) ...................................................................................... TWE180B
BAYBASE005A1 ............. Subbase (921/2 W x 307/16 L) ..................................................................................... TWE240B
BAYDRKT001A ................. Condensate Drain Kit ................................................................................................ TWE060
BAYDRKT002A ................. Condensate Drain Kit ................................................................................................ TWE090
BAYDRKT003A ................. Condensate Drain Kit ................................................................................................ TWE120
BAYDRKT004A ................. Condensate Drain Kit ................................................................................................ TWE180
BAYDRKT005A ................. Condensate Drain Kit ................................................................................................ TWE240
BAYGRLE001A ................. Return Air Grille ......................................................................................................... TWE060A, TWE060B
BAYGRLE002A ................. Return Air Grille ......................................................................................................... TWE090A, TWE090B
BAYGRLE003A ................. Return Air Grille ......................................................................................................... TWE120A, TWE120B
BAYGRLE004A ................. Return Air Grille ......................................................................................................... TWE180B
BAYGRLE005A ................. Return Air Grille ......................................................................................................... TWE240B
BAYHSMT022B ................. Oversized Motor 230/1/60 – 1 HP ............................................................................. TWE060A, TWE060B
BAYHSMT023B ................. Oversized Motor 230/1/60 – 2 HP ............................................................................. TWE090A, TWE090B
BAYHSMT025B ................. Oversized Motor 230-460/3/60 – 1 HP ...................................................................... TWE060A3, A4, B3, B4
BAYHSMT026A ................. Oversized Motor 230-460/3/60 – 2 HP ...................................................................... TWE090A3, TWE090B3
BAYHSMT027B ................. Oversized Motor 230-460/3/60 – 3 HP ...................................................................... TWE120A3
BAYHSMT028A ................. Oversized Motor 230/3/60 – 5 HP ............................................................................. TWE180B3
BAYHSMT029A ................. Oversized Motor 230-460/3/60 – 7.5 HP ................................................................... TWE240B3,B4
BAYHSMT030A ................. Oversized Motor 460/3/60 – 5 HP ............................................................................. TWE180B4
BAYHSMT035AA ............... Oversized Motor 575/3/60 – 5 HP ............................................................................. TWE180BW
BAYHSMT036AA ............... Oversized Motor 575/3/60 – 7.5 HP .......................................................................... TWE240BW
BAYISLT003A234 ........ Rubber-In-Shear Isolator - Floor ................................................................................ TWE060-090A, TWE060-090B
BAYISLT004A234 ........ Rubber-In-Shear Isolator - Floor ................................................................................ TWE120A, TWE120B
BAYISLT009A13 ............ Rubber-In-Shear Isolator - Floor ................................................................................ TWE180B
BAYISLT012B1 ............... Rubber-In-Shear Isolator - Suspended ...................................................................... TWE180B
BAYISLT013B34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE060A, TWE060B
BAYISLT014A34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE090A, TWE090B
BAYISLT015B34 ............ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE120A, TWE120B
BAYISLT016B1 ............... Rubber-In-Shear Isolator - Suspended ...................................................................... TWE240B
BAYISLT018A23 ............ Spring Isolater - Floor ................................................................................................ TWE060A, TWE060B
BAYISLT019A23 ............ Steel Spring Isolater - Floor ....................................................................................... TWE090-120A, TWE090-120B
BAYISLT021A12 ............ Rubber-In-Shear Isolator - Floor ................................................................................ TWE180-240B
BAYISLT028A3 ............... Steel Spring Isolater - Suspended ............................................................................. TWE060A, TWE060B
BAYISLT029A3 ............... Spring Isolater - Suspended ...................................................................................... TWE090-120A, TWE090-120B
BAYISLT030A1 ................ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE180B
BAYISLT031B1 ................ Rubber-In-Shear Isolator - Suspended ...................................................................... TWE240B
BAYLSDR001A .................. Low Static Drive Kit ................................................................................................... TWE240B
BAYLSDR003A .................. Low Static Drive Kit ................................................................................................... TWE090A, TWE090B
BAYPLNM015A56 ......... Discharge Plenum and Grille ..................................................................................... TWE060A, TWE060B
BAYPLNM016A56 ......... Discharge Plenum and Grille ..................................................................................... TWE090A, TWE090B
BAYPLNM017A56 ......... Discharge Plenum and Grille ..................................................................................... TWE120A, TWE120B
BAYPLNM018A56 ......... Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR015A, 020B
BAYPLNM019A56 ......... Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR016A, 021B
BAYPLNM020A5 ............. Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR012A, 017B
BAYPLNM021A5 ............. Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR013A, 018B
BAYPLNM022A5 ............. Hydronic Coil Discharge Plenum and Grille .............................................................. BAYWATR014A, 019B
BAYPLNM025A7 ............. Electric Heat Discharge Plenum and Grille For use with TWE060A, TWE060B ....... BAYHTRL117A, 315A, 415A
BAYPLNM026A7 ............. Electric Heat Discharge Plenum and Grille ............................................................... BAYHTRL117A, 123A, BAYHTRL315A, 325A,
For use with TWE090A, TWE090B ............................................................................ BAYHTRL415A, 425A
BAYPLNM027A7 ............. Electric Heat Discharge Plenum and Grille ............................................................... BAYHTRL117A, 123A, BAYHTRL315A, 325A,
For use with TWE120A, TWE120B ............................................................................ BAYHTRL415A, 425A
BAYPLNM028A7 ............. Electric Heat Discharge Plenum and Grille - 15 Ton ................................................. BAYHTRM330A,430A,W30A
BAYPLNM029A7 ............. Electric Heat Discharge Plenum and Grille - 20 Ton ................................................. BAYHTRM330A,430A,W30A
BAYTFMR003A89 ......... 77va Transformer 230v/24v ....................................................................................... TWE090-120A3, TWE090-120B3
BAYTFMR004A890 ...... 77va Transformer 460v/24v ....................................................................................... TWE090-120A3, TWE090-120B3
BAYTFMR005A89 ......... 77va Transformer 575v/24v ....................................................................................... TWE090AW,TWE120AW,BW
BAYTFMR007A89q ...... 75va Transformer Relay and Terminal Connections 230v/24v .................................. TWE090B3-TWE120B3
BAYTFMR008A80q ...... 87va Transformer Relay and Terminal Connections 460v/24v .................................. TWE090B3-TWE120B3
BAYWATR012A ................. Steam Coil Encl. & Assm. (38 W x 221/8 L x 14 H) ................................................... TWE60A, TWE060B
BAYWATR013A ................. Steam Coil Encl. & Assm. (475/8 W x 253/16 L x 14 H) ............................................... TWE090A, TWE090B
BAYWATR014A ................. Steam Coil Encl. & Assm. (635/8 W x 253/16 L x 16 H) ............................................... TWE120A, TWE120B
BAYWATR015A ................. Steam Coil Encl. & Assm. (795/8 W x 2713/16 L x 16 H) .............................................. TWE180B
BAYWATR016A ................. Steam Coil Encl. & Assm. (925/8 W x 305/8 L x 18 H) ................................................ TWE240B
BAYWATR017C ................. Hot Water Coil Encl. & Assm. (38 W x 221/8 L x 14 H) .............................................. TWE060A, TWE060B
BAYWATR018C ................. Hot Water Coil Encl. & Assm. (475/8 W x 253/16 L x 14 H) ......................................... TWE090A, TWE090B
BAYWATR019C ................. Hot Water Coil Encl. & Assm. (635/8 W x 253/16 L x 16 H) ......................................... TWE120A, TWE120B
BAYWATR020C ................. Hot Water Coil Encl. & Assm. (795/8 W x 2713/16 L x 16 H) ........................................ TWE180B
BAYWATR021C ................. Hot Water Coil Encl. & Assm. (925/8 W x 305/8 L x 18 H) .......................................... TWE240B
BAYWRKT001A ............... Wire Kit to Achieve 180° Reversible Discharge ......................................................... TWE060-090-120A, TWE060-090-120B
1 When Air Handler is in vertical position and close proximity trapping of condensate is required, 6 Discharge Plenum and Grille cannot be used with Electric or Hydronic Heat options.
use of subbase is recommended. 7 See data catalog for minimum and maximum airflow requirements.
2 Requires use of subbase accessory. 8 Required when 71/2 – 10 ton Air Handlers are matched with 4 – 6 ton outdoor units.
3 Do not use with units having steam or hot water coil. 9 Required when used with Qty 2 Split System condensing units.
4 Do not use if blower will operate less than 600 rpm. 0 When field connected for 460V.
5 For vertical use only. q Required when used with Qty 2 Split System Heat Pump.

For complete equipment / combination


selections and installation instructions, please AH-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System Air Handlers
5 through 20 Tons

Factory Supplied
Accessories
A Air Handler (TWE 5 – 20 Tons)

EH B Outdoor Condensing Unit


(TTA - Cooling 7 1/2 – 20 Tons)
(TWA - Heat Pump 7 1/2 – 20 Tons)
P Discharge Plenum and Grille
(BAYPLNM)
P
EH Electric Heater and Casing (BAYHTRL)
Fits on Top of Unit (13 H x 30 W x 17 D)
SB Subbase (BAYBASE)
I Isolators (BAYISLT)
RG Return Grille (BAYGRLE)
CG Coil Guards (BAYGARD)
LA Low Ambient Control (BAYLOAM)
WC Steam/Hot Water Coil (BAYWATR)
WC

To Convert from Vertical to


Horizontal Simply Lay Down

Drain Connections at Top


and Bottom of Coil

SB

I
I
RG

Drain Connections at Top


CG and Bottom of Coil

LA

For complete equipment / combination


Effective 1/1/06 AH-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
FURNACE

TRANE
XT90
TRANE XT90 HIGH EFFICIENCY FURNACE
Trane Profit-ability
Sell-ability
Industry leader and brand reputation
Higher efficiency single-stage furnace
Greater reliability
Quieter operation
Install-ability
Air cleaner and humidifier leads
Upflow/horizontal left
Downflow/horizontal right
Left/right gas and electrical hookups
Direct-vent option
TRANE LIMITED WARRANTY
Lifetime heat exchanger
Service-ability 5-year functional parts
Quarter-turn blower door latches
on upflow models
Self-diagnostic controls
Common parts across family
Compatible with higher SEER
outdoor units
Performance-ability
4-speed, high efficiency motor
90% efficiency on gas
Insulated blower door and cabinet
save energy and reduce sound
Automotive-grade gaskets reduce
air sound and infiltration
Rely-ability MORE ENHANCED COMFORT, EXTRA-EFFICIENT PROFITS.
Each is factory tested before shipping The TRANE XT90 furnace provides a higher efficiency, construction and replacement. It’s easy to install
Silicon nitride igniter single-stage furnace option with a bonus of added and service. And can accommodate upgrades to higher
100% fresh air option reliability. Because it uses less electricity in both SEER outdoor units. Install it and provide an enhanced
Integrated furnace control
its heating and cooling operations, it will appeal to comfort experience that will make you and your
Aluminized heat exchanger
efficiency-minded customers for residential new customers more comfortable, too.
Multi-port in-shot burners

Reliable performance Better indoor air Comfort control Enhanced comfort Efficient operation
Precision engineering, design Add a TRANE CleanEffects TM
Give your customers better Intelligently designed to Designed with innovative
innovation and rigorous testing air filtration system to remove up to comfort control with a Trane deliver maximum comfort with technological touches throughout
for reliable, long-lasting 99.98% of airborne allergens from digital or programmable fuel efficiency. to provide the ultimate in energy
performance and durability. the filtered air for a cleaner, more thermostat. efficient operation that lowers
comfortable home. customers’ heating costs.

15633 XT90 Furnace.indd 1 9/13/05 1:41:43 PM


FURNACE

TRANE
XT90
TRANE XT90 HIGH EFFICIENCY FURNACE
1 High efficiency blower motor 6 Multi-port in-shot burners
9 Controlled by a built-in microcomputer and on-board Perfectly shape the flame cone for the maximum heat possible
relays. Fixed 45-second time delay controls the indoor while using less fuel. No service adjustment necessary.
2 8 blower in heating cycles. Blower off timing is adjustable
by presets, allowing you to customize comfort in the home. 7 Automotive-grade gaskets and insulated
2 Adaptive silicon nitride hot surface igniter blower compartment
6 10 Help reduce operating sound and air infiltration.
Prevents overheating, which results in a highly reliable ignition
system and longer service life. 8 Aluminized steel heat exchanger
Features and components may vary by model
and are shown for illustration purposes only.

Crimped, not welded, to prevent cracks from heat stress.


3 Heavy steel insulated cabinet Stamped serpentine channel offers the greatest efficiency
Easy-to-install sizes in four industry-standard widths; 40" in less space. Backed by our 20-year, non-prorated limited
5 tall. Holds more heat in the furnace and ensures greater warranty.
durability and quieter operation.
1 9 Direct vent
3 4 Self-diagnostic controls 100% fresh air option reduces heat exchanger corrosion and
4
7 Complete diagnostics for easy servicing. Also includes a assures adequate combustion air.
system fault analysis for quick gas flow shutoff, coupled with
automatic ignition retry after sensing fault correction. 10 Secondary heat exchanger
The secondary heat exchanger is made of AL29-4CTM stainless
5 Easy-access doors steel to capture more of the heat your customers pay for.
Quarter-turn dual door latches provide quick and easy Backed by a lifetime limited warranty.
access for servicing (upflow models only).

Warranties generate additional income.


XT90 High Efficiency, Upflow, Horizontal Left Trane extended warranties create additional income. Selling extended
Cooling CFM
Model Number AFUE Height (in.) Width (in.) Depth (in.) (Nom. tons) warranties is another way to protect your customers and generate
TUX1B040A9H21A 92.1 40.00 17.50 28.00 2.0 future business.
TUX1B060A9H31A 92.1 40.00 17.50 28.00 3.0
TUX1B080A9H31A 92.1 40.00 17.50 28.00 3.0 It all adds up to a stellar reputation.
TUX1C100A9H41A 92.1 40.00 21.00 28.00 4.0 We know that when you recommend our products to your loyal customers,
TUX1D120A9H51A 92.1 40.00 24.50 28.00 5.0
you are placing your livelihood and reputation in our hands. We salute
XT90 High Efficiency, Downflow, Horizontal Right your expertise in delivering Trane technology and innovation to your
TDX1B040A9H31A 91.0 40.00 17.50 28.00 3.0
customers — making their homes better places for living. You are the
TDX1B060A9H31A 91.0 40.00 17.50 28.00 3.0
TDX1B080A9H31A 91.0 40.00 17.50 28.00 3.0 reason we can say, “expect more from Trane.”
TDX1C100A9H41A 91.0 40.00 21.00 28.00 4.0
TDX1D120A9H51A 91.0 40.00 24.50 28.00 5.0
As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice.

trane.com

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. XT90FURN-01 09/05

15633 XT90 Furnace.indd 2 9/13/05 1:41:44 PM


FURNACE

TRANE
XT80
TRANE XT80 HIGH EFFICIENCY FURNACE
Trane Profit-ability
Sell-ability
Industry leader and brand reputation
Higher efficiency single-stage furnace
Greater reliability
Quieter operation

Install-ability
Air cleaner and humidifier leads
Upflow/horizontal left or right
Downflow/horizontal left or right
Left/right gas and electrical hookups TRANE LIMITED WARRANTY
20-year heat exchanger
Service-ability 5-year functional parts
Quarter-turn blower door latches
on upflow models
Self-diagnostic controls
Common parts across family
Compatible with higher SEER
outdoor units

Performance-ability
4-speed high efficiency motor
80% efficiency on gas
Insulated blower door and cabinet
save energy and reduce sound
Automotive-grade gaskets reduce
air sound and infiltration
OUR NEW SINGLE-STAGE, HIGH EFFICIENCY XT80 FURNACE REALLY HEATS UP YOUR SALES.
Rely-ability With a high efficiency motor, the TRANE XT80 furnace service. It also can accommodate upgrades to higher
Each is factory tested before shipping
sets the stage for increased sales. It uses less SEER outdoor units. The XT80 furnace is a high
Silicon nitride igniter
electricity in both its heating and cooling operations, efficiency product that both you and your customers
Integrated furnace control
Aluminized heat exchanger so it’s very attractive for new residential construction can be comfortable with.
Multi-port in-shot burners and replacement. And it’s easy for you to install and

Reliable performance Better indoor air Comfort control Enhanced comfort Efficient operation
Precision engineering, design Add a TRANE CleanEffects air
TM
Give your customers better comfort Intelligently designed to Designed with innovative
innovation and rigorous testing filtration system to remove up to control with a Trane digital or deliver maximum comfort with technological touches throughout
for reliable, long-lasting 99.98% of airborne allergens from programmable thermostat. fuel efficiency. to provide the ultimate in energy
performance and durability. the filtered air for a cleaner, efficient operation.
more comfortable home.

15633 XT80 Furnace.indd 1 9/14/05 10:03:31 AM


FURNACE

TRANE
XT80
TRANE XT80 HIGH EFFICIENCY FURNACE
1 High efficiency blower motor 5 Easy-access doors
Controlled by a built-in microcomputer and on-board Quarter-turn dual door latches provide quick and easy
2 8 relays. Fixed 45-second time delay controls the indoor access for servicing (upflow models only).
blower in heating cycles. Blower off-timing is adjustable by
presets, allowing you to customize comfort in the home. 6 Multi-port in-shot burners
Perfectly shape the flame cone for the maximum heat
2 Adaptive silicon nitride hot surface igniter possible while using less fuel. No service adjustment
Prevents overheating, which results in a highly reliable necessary.
6 ignition system and longer service life.
7 Automotive-grade gaskets and insulated
Features and components may vary by model
and are shown for illustration purposes only.

5 3 Heavy steel insulated cabinet blower compartment


Comes in easy-to-install sizes in four industry standard widths; Help reduce operating sound and air infiltration.
1 40" tall. Holds more heat in the furnace and ensures greater
4 durability and quieter operation. 8 Aluminized steel heat exchanger
7 3
4 Self-diagnostic controls Crimped, not welded, to prevent cracks from heat stress.
Stamped serpentine channel offers the greatest efficiency
Complete diagnostics for easy servicing. Also includes a sys- in less space. Backed by our 20-year, non-prorated limited
tem fault analysis for quick gas flow shutoff, coupled with warranty.
automatic ignition retry after sensing fault correction.

Warranties generate additional income.


XT80 High Efficiency, Upflow Horizontal
Cooling CFM Trane extended warranties create additional income. Selling extended
Model Number AFUE Height (in.) Width (in.) Depth (in.) (Nom. tons) warranties is another way to protect your customers and generate
TUD1A040A9H21A 80.0 40.00 14.50 28.00 2.0 future business.
TUD1B060A9H31A 80.0 40.00 17.50 28.00 3.0
TUD1B080A9H31A
TUD1C080A9H41A
80.0
80.0
40.00
40.00
17.50
21.00
28.00
28.00
3.0
4.0
It all adds up to a stellar reputation.
TUD1B100A9H31A 80.0 40.00 17.50 28.00 3.0 We know that when you recommend our products to your loyal customers,
TUD1C100A9H51A 80.0 40.00 21.00 28.00 5.0 you are placing your livelihood and reputation in our hands. We salute
TUD1D120A9H51A 80.0 40.00 24.50 28.00 5.0
TUD1D140A9H51A 80.0 40.00 24.50 28.00 5.0
your expertise in delivering Trane technology and innovation to your
customers — making their homes better places for living. You are the
XT80 High Efficiency, Downflow Horizontal reason we can say “expect more from Trane.”
TDD1B060A9H31A 80.0 40.00 17.50 28.00 3.0
TDD1B080A9H31A 80.0 40.00 17.50 28.00 3.0
TDD1C100A9H51A 80.0 40.00 21.00 28.00 5.0
TDD1D120A9H51A 80.0 40.00 24.50 28.00 5.0

As part of our continuous product improvement, Trane reserves the right to change specifications and design without notice.

trane.com

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. XT80FURN-01 09/05

15633 XT80 Furnace.indd 2 9/14/05 10:03:32 AM


COILS
TR AL
TRANE ALUMINUM HIGH EFFICIENCY COMFORTTM COILS

Trane Profit-ability
Sell-ability
Industry leader with impeccable
brand reputation
Precision engineered
TRANE LIMITED WARRANTY
Install-ability 10-year functional parts
Flush fit, easy attachment
Available for different furnace widths
Upflow, downflow and horizontal
left airflow

Service-ability
Easy-access cabinet
Suction pressure service port
Removable inner and outer panels
TXV with mechanical fittings

Performance-ability
Two-way, sloped drain pan INNOVATIVE TECHNOLOGY. INCREASED PROFIT MARGIN.
Foil-insulated cabinet Corrosion has been a long-standing problem affecting efficiency there is and exceptional durability when
Non-bleed TXV every major HVAC manufacturer. Trane’s answer to selecting this indoor coil for their matched system. The
this environmental issue is the all-new, all-aluminum innovative advancement and precision engineering
Rely-ability
Non-corrosive parts Comfort™ coil—the only one of its kind in the industry. of the aluminum Comfort coil will be a money-saving

TXV protects from refrigerant By being corrosion and rust resistant, the aluminum investment for your customer and a profit-earning
flooding Comfort coil promises your customers the highest sale for you.

Reliable performance Cleaner air Comfort Control Efficient operation


Precision engineering, design Add a TRANE CleanEffects air cleaner to
TM
Give your customers better The Comfort coil increases efficiency
innovation and rigorous testing for remove up to 99.98% of airborne allergens comfort control with a Trane digital to help substantially lower customers’
reliable, long-lasting performance from the filtered air for a cleaner, or programmable thermostat. home utility costs.
and durability. more comfortable home.

15633 Aluminum Coils.indd 1 9/19/05 9:07:31 AM


COILS
TR AL
TRANE ALUMINUM HIGH EFFICIENCY COMFORTTM COILS

1 Foil insulation 4 Baked-on high gloss finish


4 100% foil-backed insulation provides easy cleaning for Provides increased protection from rust and corrosion.
cleaner air, reduced sound operation. Matches furnace in color.
1 2 Two-way, sloped, non-corrosive drain pan 5 External service port
Prevents standing water and reduces bacteria growth which To maintain higher performance with quicker and easier
significantly improves indoor air quality. Manufactured with serviceability. Allows indoor evacuation and charging.
5 non-corrosive material to prevent rust. Decreases service and unit down time.

3 3 Easy-access inner coil panel 6 TXV with mechanical fittings


Makes cleaning and servicing easier which in turn leads Allows replacement without brazing.
to higher efficiency and longer life. Improves installation
and service time.
6

Features and components may vary by model and


are shown for illustration purposes only.

HI-EFFICIENCY CASED UPFLOW/DOWNFLOW/HORIZONTAL LEFT (Refrigerant R-22)


Warranties generate additional income.
Nominal Uncrated Trane extended warranties create additional income. Selling extended
Cap. Clg. Ref. Dimensions (in.)
warranties is another way to protect your customers and generate
Model (BTUH) Type Control Cased H W D
future business.
2TXCB025AS3HCA 24,000 A HP TXV-NB Full 17.6 17.5 21.5
2TXCB031AS3HCA 30,000 A HP TXV-NB Full 22.6 17.5 21.5 It all adds up to a stellar reputation.
2TXCB036AS3HCA 36,000 A HP TXV-NB Full 26.9 17.5 21.5
We know that when you recommend our products to your loyal cus-
2TXCC037AS3HCA 37,000 A HP TXV-NB Full 26.9 21.0 21.5
tomers you are placing your livelihood and reputation in our hands. We
2TXCC054AS3HCA 54,000 A HP TXV-NB Full 30.1 21.0 21.5
salute your expertise in delivering Trane technology and innovation to
2TXCD065AS3HCA 60,000 A HP TXV-NB Full 30.1 24.5 21.5
your customers—making their homes a better place for living. You are
HI-EFFICIENCY CASED UPFLOW/DOWNFLOW/HORIZONTAL LEFT (Refrigerant R-410A) the reason we can say “expect more from Trane.”
4TXCB025AS3HCA 24,000 A HP TXV-NB Full 17.6 17.5 21.5
4TXCB031AS3HCA 30,000 A HP TXV-NB Full 22.6 17.5 21.5
4TXCB036AS3HCA 36,000 A HP TXV-NB Full 26.9 17.5 21.5
4TXCC037AS3HCA 37,000 A HP TXV-NB Full 26.9 21.0 21.5
4TXCC054AS3HCA 54,000 A HP TXV-NB Full 30.1 21.0 21.5 trane.com
4TXCD065AS3HCA 60,000 A HP TXV-NB Full 30.1 24.5 21.5
As part of our continuos product improvement, Trane reserves the right to change specifications and design without notice.

© 2005 TRANE® a business of American Standard Companies. All rights reserved. Pub. No. ALCOILS-01 09/05

15633 Aluminum Coils.indd 2 9/19/05 9:07:32 AM


XV, XL, XT, XR, XB 90 Convertible
Gas Furnaces Airflow Directions

Note: Coil access is opposite of furnace.

For complete equipment / combination


selections and installation instructions, please FUR-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XV, XL 90
Convertible Gas Furnaces

Airflow Directions:
Downflow models when placed in horizontal position provide left to right airflow.
Upflow models when placed in horizontal position provide right to left airflow.

Table FUR-2-A — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUY060R9V3W 3 56,000 37,000 93.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 156 15 17 x 25 x 1
TUY080R9V3W 3 73,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 17 x 25 x 1
TUY100R9V4W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 197 15 20 x 25 x 1
TUY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 24 x 25 x 1
XV 90 Direct/ Note: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.
Non- Direct Vent

Table FUR-2-B — XV Direct/Non-Direct Vent, Two-Stage, One or Two Pipe, Variable Speed, Downflow/
Horizontal Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDY060R9V3W 3 56,000 36,000 92.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 160 15 (2) 14 x 20 x 1
TDY080R9V3W 3 74,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 (2) 14 x 20 x 1
TDY100R9V4W 4 94,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1
TDY120R9V5W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
XV 90 Direct/ Note: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.
Non- Direct Vent

Table FUR-2-C — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX060R936W 3 56,000 36,000 93.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 156 15 17 x 25 x 1
TUX080R942W 31/2 73,000 48,000 92.5 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 17 x 25 x 1
TUX100R948W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21x 28 197 15 20 x 25 x 1
TUX120R960W 5 112,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 24 x 25 x 1
XL 90 Direct/
Non-Direct Vent

Table FUR-2-D — XL 90 Direct/Non-Direct Vent, Two Stage, One or Two Pipe, Downflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX060R936W 3 55,000 36,000 92.0 2-3 Silicon Nitride 40 x 171/2 x 28 160 15 (2) 14 x 20 x 1
TDX080R942W 31/2 74,000 48,000 92.5 2-3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDX100R948W 4 93,000 60,000 93.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 15 (2) 16 x 20 x 1
TDX120R960W 5 111,000 72,000 92.5 3 Only Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
XL 90 Direct/ 1 Isolated Combustion System.
Non-Direct Vent * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 FUR-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XT, XR 90
Convertible Gas Furnaces

Table FUR-3-A — XT 90 Direct/Non-Direct Vent, Single-Stage, One or Two Pipe, Upflow/Horizontal


Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX1B040A9H21A 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUX1B060A9H31A 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1
TUX1B080A9H31A 3 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1
TUX1C100A9H41A 4 94,000 92.1 21/2, 3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1
TUX1D120A9H51A 5 113,000 92.1 21/2, 3 Silicon Nitride 40 x 241/2 x 28 205 20 24 x 25 x 1

Table FUR-3-B — XT 90 Direct/Non-Direct Vent, Single-Stage, One or Two Pipe, Downflow/Horizontal


XT 90 Direct/ Condensing Gas Furnace (115/1/60)
Non- Direct Vent
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX1B040A9H21A 3 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1
TDX1B060A9H31A 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDX1B080A9H31A 3 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 15 (2) 14 x 20 x 1
TDX1C100A9H41A 4 94,000 91.0 21/2, 3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDX1D120A9H51A 5 112,000 91.0 21/2, 3 Silicon Nitride 40 x 241/2 x 28 206 20 (2) 16 x 20 x 1

Table FUR-3-C — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX1B040A9241A 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUX1B060A9361A 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1
TUX1B080A9421A 31/2 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1
TUX1C080A9601A 5 76,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1
TUX1C100A9481A 4 94,000 92.1 21/2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1
TUX1D100A9601A 5 93,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1
XR 90 Direct Vent
TUX1D120A9601A 5 113,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 205 15 24 x 25 x 1

Table FUR-3-D — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX1B040A9241A 2 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1
TDX1B060A9361A 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDX1B080A9421A 31/2 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDX1C100A9481A 4 94,000 91.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDX1D120A9601A 5 112,000 91.0 21/2-3 Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
1 Isolated Combustion System.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Filters are not shipped with furnace.

For complete equipment / combination


selections and installation instructions, please FUR-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XR, XB 90
Convertible Gas Furnaces

Table FUR-4-A — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Upflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUX040C924D 2 38,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUX060C936D 3 56,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 150 15 17 x 25 x 1

PHASED OUT
TUX080C942D 31/2 74,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 158 15 17 x 25 x 1
TUX080C960D 5 76,000 92.1 2, 21/2, 3 Silicon Nitride 40 x 21 x 28 171 15 20 x 25 x 1
TUX100C948D 4 94,000 92.1 21/2-3 Silicon Nitride 40 x 21 x 28 171 20 20 x 25 x 1
TUX100C960D 5 93,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1
TUX120C960D 5 113,000 92.1 21/2-3 Silicon Nitride 40 x 241/2 x 28 205 15 24 x 25 x 1

Table FUR-4-B — XR 90 Direct/Non-Direct Vent, Single Stage, One or Two Pipe, Downflow/Horizontal
Condensing Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
XR 90 Direct Vent Unit In Output 1
ICS1 Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDX040C924D 2 38,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1

PHASED OUT
TDX060C936D 3 56,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDX080C942D 31/2 74,000 91.0 2, 21/2, 3 Silicon Nitride 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDX100C948D 4 94,000 91.0 21/2-3 Silicon Nitride 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDX120C960D 5 112,000 91.0 21/2-3 Silicon Nitride 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1

Table FUR-4-C — XB 90 Single Stage, Single Pipe, Upflow/Horizontal Left Condensing Gas Furnace
(115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUC040C924B 2 37,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 139 15 17 x 25 x 1
TUC060C936B 3 56,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 150 15 17 x 25 x 1
TUC080C942B 31/2 74,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 158 15 17 x 25 x 1
TUC100C948B 4 94,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 21 x 28 171 20 20 x 25 x 1
TUC100C960B 5 93,000 92.1 2, 21/2, 3 Silicon Carbide 40 x 241/2 x 28 197 15 24 x 25 x 1
TUC120C960B 5 113,000 92.1 3 Only Silicon Carbide 40 x 241/2 x 28 205 15 24 x 25 x 1

Table FUR-4-D— XB 90 Single Stage, Single Pipe, Downflow/Horizontal Right Condensing Gas Furnace
(115/1/60)
XB 90 Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDC040C924B 2 38,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 145 15 (2) 14 x 20 x 1
TDC060C936B 3 56,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 155 15 (2) 14 x 20 x 1
TDC080C942B 31/2 74,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 171/2 x 28 168 20 (2) 14 x 20 x 1
TDC100C948B 4 93,000 91.0 2, 21/2, 3 Silicon Carbide 40 x 21 x 28 185 20 (2) 16 x 20 x 1
TDC120C960B 5 112,000 91.0 3 Only Silicon Carbide 40 x 241/2 x 28 206 15 (2) 16 x 20 x 1
1 Isolated Combustion System.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 FUR-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XV, XL, XT, XR, XB 90
Convertible Gas Furnaces
XV 90 XL 90 XT 90 XR 90 XR 90 XB 90
Airflow Directions:
Downflow models when placed in horizontal position provide left TUY/TDY TUX-R/TDX-R TUX1/TDX1 TUX1/TDX1 TUX/TDX-C TUC/TDC
to right airflow. Upflow models when placed in horizontal position 2 Stage/1-2 Pipe 2 Stage 1 Stage 1 Stage 1 Stage 1 Stage
provide right to left airflow. Variable Speed 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1or 2 Pipe 1 Pipe
Direct/Non Direct/Non High Efficiency Direct/Non Direct/Non Non
Direct Vent Direct Vent Direct/Non Direct Vent Direct Vent DirectVent
Table FUR-5-A — Features Direct Vent
• Comfort”R”™ enhanced mode (cooling) ............................ ✔ — — — — —
• Adjustable heating fan off timing ........................................... ✔ ✔ ✔ ✔ ✔ ✔
• Alternate bottom/left/right return air (upflow only) ................... ✔ ✔ ✔ ✔ ✔ ✔
• Blower door safety switch .................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Bottom panel ..................................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Cleanable/Reusable high velocity filters ................................ ✔ ✔ — — ✔ —
• Complete front service access ............................................ ✔ ✔ ✔ ✔ ✔ ✔
• Direct drive, 4-speed motor ................................................. — ✔ — ✔ ✔ ✔

PHASED OUT
• Direct drive high efficiency, 4 speed motor ............................ — — ✔ — — —
• Direct drive, GE ICM variable speed blower motor ................. ✔ — — — — —
• Downflow horizontal right (downflow models only) ................. TDY TDX TDX TDX TDX TDC
• Dual PVC pipe venting (1 or 2 pipe option) ............................ ✔ ✔ ✔ ✔ ✔ —
• Single PVC pipe venting (1 pipe only) ................................... — — — — — ✔
• Dual solenoid combination gas valve and regulator ............... ✔ ✔ ✔ ✔ ✔ ✔
• Gasketed blower door ......................................................... ✔ ✔ ✔ ✔ ✔ —
• Heavy gauge reinforced wrap-around steel cabinet ............... ✔ ✔ ✔ ✔ ✔ ✔
• Hinged blower door ............................................................ ✔ ✔ ✔ ✔ ✔ —
• Humidifier/EAC hook-up capability (factory wired) ................. ✔ ✔ ✔ ✔ ✔ ✔
• Inner blower door panel, downflow models only .................... TDY TDX TDX TDX TDX TDC
• Insulated blower compartment 4 sides ................................. ✔ ✔ ✔ ✔ ✔ —
• Cleanable Filters ................................................................ ✔ ✔ — — ✔ —
• Internal filter rack ................................................................ ✔ ✔ — — ✔ —
• Left/right condensate drain capability in vertical application ..... ✔ ✔ — ✔ ✔ ✔
• Lite Port/Stored diagnotics .................................................. ✔ ✔ — — — —
• Mobile home approved w/BAYMFGH100A ........................... ✔ ✔ ✔ ✔ ✔ —
• Multi-port in shot burners ..................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Painted cabinet single color ................................................. — — — — — ✔
• Painted cabinet two tone color ............................................. ✔ ✔ ✔ ✔ ✔ —
• Service diagnostic capabilities ............................................. ✔ ✔ ✔ ✔ ✔ ✔
• Side out blower assembly ................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Side return duct starter tabs ................................................ ✔ ✔ ✔ ✔ ✔ ✔
• Silicon Carbide hot surface igniter with adaptive heat up ........ — — — — — ✔
• Silicon Nitride hot surface igniter with adaptive heat up ........... ✔ ✔ ✔ ✔ ✔ —
• Single wire twinning ............................................................ — ✔ ✔ ✔ ✔ —
• Solid burner door (quiet operation) ....................................... ✔ ✔ ✔ ✔ ✔ —
• 20 gauge aluminized steel heat exchanger ........................... ✔ ✔ ✔ ✔ ✔ ✔
• 24 volt secondary fuse ........................................................ ✔ ✔ ✔ ✔ ✔ ✔
• Two heating blower speeds ................................................. ✔ ✔ — — — —
• Two-stage gas valve ........................................................... ✔ ✔ — — — —
• Type 29-4C™ stainless steel secondary heat exchanger ....... ✔ ✔ ✔ ✔ ✔ ✔
• Upflow horizontal left (upflow models only) ............................ TUY TUX TUX TUX TUX TUC
• Variable Speed venter motor ............................................... ✔ ✔ — — — —
• Limited lifetime heat exchanger warranty to original owner and ✔ ✔ ✔ ✔ ✔ ✔
20-years to succeeding homeowner from date of installation
• 5-year limited warranty on parts* .......................................... ✔ ✔ ✔ ✔ ✔ ✔
NOTE: Variable speed XV90 furnaces should not be twinned and are not approved for twinning applications.

For complete equipment / combination


selections and installation instructions, please FUR-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XV, XL, XT, XR, XB 90
Convertible Gas Furnaces
Airflow Directions: XV 90 XL 90 XT 90 XR 90 XR 90 XB 90
Downflow models when placed in horizontal position provide left
TUY/TDY TUX-R/TDX-R TUX1/TDX1 TUX1/TDX1 TUX/TDX-C TUC/TDC
to right airflow. Upflow models when placed in horizontal position
provide right to left airflow. 2 Stage/1-2 Pipe 2 Stage 1 Stage 1 Stage 1 Stage 1 Stage
Variable Speed 1 or 2 Pipe 1 or 2 Pipe 1or 2 Pipe 1or 2 Pipe 1 Pipe
Direct/Non Direct/Non Direct/Non Direct/Non Direct/Non Non
Table FUR-6-A — Optional Accessories Direct Vent Direct Vent Direct Vent Direct Vent Direct Vent DirectVent
BAY69X146 ...........
Horizontal vent cap (Noryl) ............................ — — — — — ✔
BAY69X147 ...........
Wall mount flange – 3" .................................. — — ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔

PHASED OUT
BAY69X148 ...........
Wall mount flange – 2" .................................. — —
BAYBASE205 ........ Downflow subbase ....................................... ✔ ✔ ✔ ✔ ✔ ✔
BAYFLTR200 .........External side filter rack .................................. ✔ ✔ ✔ ✔ ✔ ✔
BAYFLTR203 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔
for 17.5" cabinet
BAYFLTR204 ........ Filter kit horiz conversion ............................. ✔ ✔ — — ✔ ✔
for 21" cabinet
BAYFLTR205 ........ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔
for 24.5" cabinet
BAYFLTR206 ........ Filter kit ....................................................... — — ✔ ✔ ✔ ✔
BAYFLTR3171 .... Cleanable filter for 17.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔
cabinet upflow only
BAYFLTR3211 .... Cleanable filter for 21" ............................... ✔ ✔ ✔ ✔ ✔ ✔
cabinet upflow only
BAYFLTR3241 .... Cleanable filter for 24.5" ............................. ✔ ✔ ✔ ✔ ✔ ✔
cabinet upflow only
BAYLPKT210B ..... Propane conversion kit .................................. ✔ ✔ ✔ ✔ ✔ ✔
BAYLPSS210B .... LP Kit with Stainless ................................... ✔ ✔ ✔ ✔ ✔ ✔
Steel Burners
BAYMFGH100A .... Manufactured/mobile .................................. ✔ ✔ ✔ ✔ ✔ —
home kit
BAYRACK960A .... Filter rack kit for upflow ............................... TUY TUX ✔ TUX TUX TUC
models only (internal)23
BAYVENT100A ..... Concentric vent kit for 2, ............................. ✔ ✔ ✔ ✔ ✔ —
1
2 /2 and 3" vent system
BAYVENT200B ..... Sidewall vent Terminator ............................. ✔ ✔ ✔ ✔ ✔ —
Kit for Direct vent furnaces
1 Contains one (1) high velocity filter. 3 Includes 17" Cleanable Filter.
2 Internal filter rack for side or bottom return air. NOTE: Variable Speed XV90 Furnaces should not be twinned and are not approved for twinning applications.

Special Use Furnace Accessories


Table FUR-6-B — High Altitude Pressure Switch 90%
Model Shipping
Number Description Used With Weight
BAYHALT225 1 Switch TUC0 80,100C948,120C, TDC080,120C 2
BAYHALT226 1 Switch TUC,TDC060C 2
BAYHALT227 1 Switch TUC100C948 2
BAYHALT228 1 Switch TUC/TDC040C 2
BAYHALT230 1 Switch TUX/TDX040C, TUX1B040,D100/TDX1B040 2
BAYHALT231 1 Switch TUX060C, TUX1060C 2
BAYHALT232 1 Switch TUX080C, TUX1B080C 2
BAYHALT233 1 Switch TUX100,120C/TDX080,120C, TUX1C100,D120/TDX1B080,D120 2
BAYHALT234 1 Switch TDX100C, TDX1C100 2
BAYHALT241 1 Switch TDX060C, TDX1B060 2
BAYHALT245 2 Switches TDX/TUX/TDY/TUY060-R 2
BAYHALT246 2 Switches TDX/TUX/TDY/TUY080,100-R 2
BAYHALT247 2 Switches TDX/TUX/TDY/TUY120-R 2
BAYSWT01AMALTA 1 Switch TUX/TDX120C,100C948,TUX/TDX1D120-9601,1C100-9481 2

Table FUR-6-C — Dual Fuel Heat Pump Control Kit12


Model Number Case Height Used With
TAYPLUS103A ............. Heat Pump Control Kit .............. Gas, LP., Oil and Electric Furnaces
TAYSTAT250B .............. Outdoor Thermostat ................. TAYPLUS103A for Restricted Mode
THT1248 ....................... Bonnet Switch .......................... Oil Furnaces Only (Order Separately)
Bonnet TAYPLUS103A 1 Factory wired for non-restricted mode, can be wired for restricted mode.
Switch 2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required).

For complete equipment / combination


Effective 1/1/06 FUR-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XV, XL, XT, XR, XB 80 Convertible
Gas Furnaces Airflow Directions

For complete equipment / combination


selections and installation instructions, please FUR-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XV, XL 80, Convertible
Gas Furnaces

Table FUR-8-A — XV 80 Variable Speed, Two-Stage, Upflow/Horizontal Left or Right Induced Draft Gas
Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUD060R9V3K 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 136 15 17 x 25 x 1
TUD080R9V3K 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080R9V4K 4 64,000 41,600 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 17 x 25 x 1
TUD100R9V3K 3 80,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD100R9V5K 5 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 20 x 25 x 1
XV 80 TUD120R9V5K 5 97,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 15 24 x 25 x 1
TUD140R9V5K 5 111,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 24 x 25 x 1
NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.

Table FUR-8-B — XV 80 Variable Speed, Two-Stage, Downflow/Horizontal Left or Right Induced Draft Gas
Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDD060R9V3F 3 48,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 140 15 (2) 14 x 20 x 1
TDD080R9V3F 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD100R9V5F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1
TDD120R9V5F 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 197 15 (2) 16 x 20 x 1
NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.
XV 80
Table FUR-8-C — XL 80 Two-Stage, Upflow/Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TUD040R924K 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1**
TUD060R936K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1**
TUD060R937K 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1
TUD080R936K 3 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080R948K 4 63,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD100R936K 3 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1
XL 80 TUD100R948K 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD100R960K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD100R961K 5 80,000 52,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1
TUD120R954K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1
TUD120R960K 5 95,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
TUD140R960K 5 112,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 192 20 24 x 25 x 1

Table FUR-8-D — XL 80 Two-Stage, Downflow/Horizontal Left or Right Induced Draft (115/1/60)


Airflow Flue Uncrated Shipping
Unit In Output (Btuh) Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons Stage 2 Stage 1 AFUE (in) Device H x W x D (Ibs.) Fuse* Sizes
TDD040R924F 2 32,000 20,800 80.0 4 Silicon Nitride 40 x 141/2 x 28 125 15 (2) 14 x 20 x 1
TDD060R936F 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 141/2 x 28 135 15 (2) 14 x 20 x 1
TDD060R937F 3 47,000 31,200 80.0 4 Silicon Nitride 40 x 171/2 x 28 147 15 (2) 14 x 20 x 1
TDD080R936F 3 64,000 41,600 80.0 4 Silicon Nitride 40 x 171/2 x 28 152 15 (2) 14 x 20 x 1
TDD100R945F 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 157 15 (2) 14 x 20 x 1
TDD100R948F 4 79,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1
XL 80
TDD100R960F 5 81,000 52,000 80.0 4 Silicon Nitride 40 x 21 x 28 168 15 (2) 16 x 20 x 1
TDD120R960F 5 96,000 62,400 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 15 (2) 16 x 20 x 1
TDD140R960F 5 113,000 72,800 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Ship with filter sizes. May be trimmed for bottom return.

For complete equipment / combination


Effective 1/1/06 FUR-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XT, XR 80
Convertible Gas Furnaces

Table FUR-9-A — XT 80 Single Stage, Upflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TUD1A040A9H21A 2 32,000 80 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1
TUD1B060A9H31A 3 47,000 80 4 Silicon Nitride 40 x 171/2 x 28 127 15 17 x 25 x 1
TUD1B080A9H31A 3 63,000 80 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD1C080A9H41A 4 64,000 80 4 Silicon Nitride 40 x 21 x 28 142 20 20 x 25 x 1
TUD1B100A9H31A 3 79,000 80 4 Silicon Nitride 40 x 171/2 x 28 151 20 17 x 25 x 1
TUD1C100A9H51A 5 79,000 80 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1
TUD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
XT 80 TUD1D140A9H51A 5 111,000 80 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1
Upflow
Table FUR-9-B — XT 80 Single Stage, Downflow Horizontal, Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDD1B060A9H31A 3 48,000 80 4 Silicon Nitride 40 x 171/2 x 28 139 15 (2) 14 x 20 x 1
TDD1B080A9H31A 3 64,000 80 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD1C100A9H51A 5 81,000 80 4 Silicon Nitride 40 x 21 x 28 167 20 (2) 16 x 20 x 1
TDD1D120A9H51A 5 96,000 80 4 Silicon Nitride 40 x 241/2 x 28 189 20 (2) 16 x 20 x 1

Table FUR-9-C — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
XT 80 Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
Downflow TUD1A040A9241A 2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 17 x 25 x 1
TUD1A040A9301A 21/2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1
TUD1A060A9241A 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1
TUD1A060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1
TUD1B060A9361A 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1
TUD1B080A9241A 2 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1
TUD1B080A9361A 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD1B080A9481A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD1C080A9601A 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1
TUD1C100A9361A 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1
TUD1C100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1
TUD1C100A9481A 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD1C100A9601A 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1
TUD1D100A9721A 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1
XR 80 TUD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1
TUD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
TUD1D140A9601A 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-9-D — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter**
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDD1A040A9241A 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 (2) 14 x 20 x 1
TDD1A060A9241A 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD1A060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD1B060A9361A 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 141 15 (2) 14 x 20 x 1
TDD1B080A9361A 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD1B080A9451A 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDD1B100A9451A 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 156 15 (2) 14 x 20 x 1
TDD1C100A9481A 4 80,000 80.0 4 Silicon Nitride 40 x 21 x 28 166 15 (2) 16 x 20 x 1
XR 80 TDD1C100A9541A 5 81,000 80.0 4 Silicon Nitride 40 x 21 x 28 167 15 (2) 16 x 20 x 1
TDD1C120A9541A 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 177 15 (2) 16 x 20 x 1
TDD1D120A9601A 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 189 15 (2) 16 x 20 x 1
TDD1D140A9601A 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
** Filters are not shipped with furnace.

For complete equipment / combination


selections and installation instructions, please FUR-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XR, XB 80
Convertible Gas Furnaces
Table FUR-10-A — XR 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
1
TUD040C924K 2 32,000 80.0 4 Silicon Nitride 40 x 14 /2 x 28 119 15 17 x 25 x 1
TUD040C930K 21/2 32,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 122 15 17 x 25 x 1
TUD060C924K 2 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 124 15 17 x 25 x 1
TUD060C936K 3 47,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 127 15 17 x 25 x 1
TUD060C937K 3 47,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 137 15 17 x 25 x 1
TUD080C924K 2 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 139 15 17 x 25 x 1

PHASED OUT
TUD080C936K 3 63,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080C948K 4 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 142 15 17 x 25 x 1
TUD080C960K 5 64,000 80.0 4 Silicon Nitride 40 x 21 x 28 154 15 20 x 25 x 1
TUD100C936K 3 79,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 151 15 17 x 25 x 1
TUD100C945K 4 80,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 153 15 17 x 25 x 1
XR 80 TUD100C948K 4 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 15 20 x 25 x 1
TUD100C960K 5 79,000 80.0 4 Silicon Nitride 40 x 21 x 28 162 20 20 x 25 x 1
TUD100C972K 6 80,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 175 20 24 x 25 x 1
TUD120C954K 5 96,000 80.0 4 Silicon Nitride 40 x 21 x 28 176 20 20 x 25 x 1
TUD120C960K 5 96,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 186 20 24 x 25 x 1
TUD140C960K 5 111,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-10-B — XR 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDD040C924F 2 31,000 78.0 4 Silicon Nitride 40 x 141/2 x 28 119 15 (2) 14 x 20 x 1
TDD060C924F 2 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD060C936F 3 48,000 80.0 4 Silicon Nitride 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDD060C937F 3 48,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 141 15 (2) 16 x 20 x 1
TDD080C936F 3 64,000 80.0 4 Silicon Nitride 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1

XR 80
TDD080C945F
TDD100C945F
TDD100C948F
TDD100C954F
TDD120C954F
TDD120C960F
PHASED OUT4
4
4
5
5
5
64,000
80,000
80,000
81,000
96,000
96,000
80.0
80.0
80.0
80.0
80.0
80.0
4
4
4
4
4
4
Silicon Nitride
Silicon Nitride
Silicon Nitride
Silicon Nitride
Silicon Nitride
Silicon Nitride
40 x 171/2 x 28
40 x 171/2 x 28
40 x 21 x 28
40 x 21 x 28
40 x 21 x 28
40 x 241/2 x 28
146
156
166
167
177
189
15
15
15
15
15
15
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
(2) 16 x 20 x 1
TDD140C960F 5 113,000 80.0 4 Silicon Nitride 40 x 241/2 x 28 196 15 (2) 16 x 20 x 1

Table FUR-10-C — XB 80 Single Stage, Upflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TUE040A924L 2 31,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 119 15 16 x 25 x 1
TUE060A936L 3 47,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 127 15 16 x 25 x 1
TUE060A937L 3 47,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 137 15 17 x 25 x 1
TUE080A936L 3 63,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 142 15 17 x 25 x 1
TUE080A948L 4 64,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 142 15 17 x 25 x 1
TUE100A936L 3 79,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 151 15 17 x 25 x 1
TUE100A948L 4 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1
TUE100A960L 5 79,000 80.0 4 Silicon Carbide 40 x 21 x 28 162 15 20 x 25 x 1
TUE120A960L 5 96,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 186 20 24 x 25 x 1
XB 80 TUE140A960L 5 111,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 193 20 24 x 25 x 1

Table FUR-10-D — XB 80 Single Stage, Downflow/Horizontal Left or Right Induced Draft Gas Furnace (115/1/60)
Airflow Nominal Flue Uncrated Shipping
Unit In Output Size Ignition Dimensions (in.) Weight Max Filter
Model No. Tons (Btuh) AFUE (in.) Device H x W x D (Ibs.) Fuse* Sizes
TDE060A936M 3 48,000 80.0 4 Silicon Carbide 40 x 141/2 x 28 129 15 (2) 14 x 20 x 1
TDE060A937M 3 48,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 134 15 (2) 14 x 20 x 1
TDE080A945M 4 64,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 146 15 (2) 14 x 20 x 1
TDE100A945M 4 80,000 80.0 4 Silicon Carbide 40 x 171/2 x 28 156 15 (2) 14 x 20 x 1
TDE100A960M 5 81,000 80.0 4 Silicon Carbide 40 x 21 x 28 167 20 (2) 16 x 20 x 1
TDE120A960M 5 96,000 80.0 4 Silicon Carbide 40 x 241/2 x 28 189 20 (2) 16 x 20 x 1
*Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
For complete equipment / combination
Effective 1/1/06 FUR-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XV, XL, XT, XR, XB 80
Convertible Gas Furnaces
Airflow Directions:
Downflow models when placed in horizontal position provide left XV 80 XL 80 XT 80 XR 80 XR 80 XB 80
to right airflow. Upflow models when placed in horizontal position TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE/TDE
provide right to left airflow. TDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-K 1 Stage
Variable Speed 2 Stage 1 or 2 Pipe 1 Stage
Table FUR-11-A — Features High Efficiency
• Comfort-R™ enhanced mode (cooling) ............................. ✔ — — — — —
• Adjustable heating fan off timing .......................................... ✔ ✔ ✔ ✔ ✔ ✔
• Adjustable internal filter rack1 ............................................ ✔ ✔ — — ✔ —
• Alternate bottom/left/right return air1 ................................... ✔ ✔ ✔ ✔ ✔ ✔
• Attractive color accents ...................................................... ✔ ✔ ✔ ✔ ✔ —
• Blower door safety switch ................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Bottom Panel1 ................................................................. ✔ ✔ ✔ ✔ ✔ —
• Cleanable/reusable high velocity filters ................................ ✔ ✔ — — ✔ —
• Common vent capability ..................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Complete front service access ........................................... ✔ ✔ ✔ ✔ ✔ ✔
• Direct drive, 4-speed motor ................................................ — ✔ ✔ ✔ ✔ ✔
• Direct drive,GE ICM variable speed blower motor ................ ✔ — — — — —

PHASED OUT
• Filter ................................................................................. ✔ ✔ — — ✔ —
• Gasketed blower door ........................................................ ✔ ✔ ✔ ✔ ✔ —
• Heavy gauge reinforced wrap-around steel cabinet .............. ✔ ✔ ✔ ✔ ✔ ✔
• Hinged blower door1 ........................................................ ✔ ✔ ✔ ✔ ✔ —
• Horizontal left/right without conversion required .................... ✔ ✔ ✔ ✔ ✔ ✔
• Humidifier/EAC hook-up capability (factory-wired) ................ ✔ ✔ ✔ ✔ ✔ —
• Inner blower door panel on downflow models only ................ ✔ ✔ ✔ ✔ ✔ ✔
• Insulated blower compartment 4 sides1 ............................. ✔ ✔ ✔ ✔ ✔ —
• Integrated solid state control w/self diagnostics .................... ✔ ✔ ✔ ✔ ✔ ✔
• Internal filter rack ............................................................... ✔ ✔ — — ✔ —
• Left/right gas connection .................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Manual reset flame roll out switches .................................... ✔ ✔ ✔ ✔ ✔ ✔
• Manually resettable burner switches ................................... ✔ ✔ ✔ ✔ ✔ ✔
• Masonry Chimney Venting w/BAYVENT800B ...................... ✔ ✔ ✔ ✔ ✔ —
• Multi-port in shot burners .................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Painted cabinet single color ................................................ — — — — — ✔
• Perfect fit door latches1 ..................................................... ✔ ✔ ✔ ✔ ✔ —
• Right or left hand side knock out for venting ......................... ✔ ✔ ✔ ✔ ✔ ✔
(downflow models only)
• Selectable cooling fan off delay eliminates need ................... ✔ ✔ ✔ ✔ ✔ ✔
for time delay relay BAY24X045
• Service diagnostic sight glass ............................................. ✔ ✔ ✔ ✔ ✔ —
• Side return starter tabs ...................................................... TUD TUD TUD TUD TUD TUE
• Silicon Carbide hot surface igniter with adaptive heat up ....... — — — — — ✔
• Silicon Nitride hot surface igniter with adaptive heat up .......... ✔ ✔ ✔ ✔ ✔ —
• Single door filter access ..................................................... ✔ ✔ ✔ ✔ ✔ —
• Single wire twinning ........................................................... — ✔ ✔ ✔ ✔ —
• Slide out blower assembly .................................................. ✔ ✔ ✔ ✔ ✔ ✔
• Standard filter sizes1 ........................................................ ✔ ✔ ✔ ✔ ✔ —
• 3-way vent option on downflow models (top,right or left) ........ ✔ ✔ ✔ ✔ ✔ ✔
(downflow only) .................................................................
• 20 gauge aluminized steel heat exchanger .......................... ✔ ✔ ✔ ✔ ✔ ✔
• 24 volt secondary fuse ....................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Two heating blower speeds ............................................... ✔ ✔ — — — —
• Two speed venter motor .................................................... ✔ ✔ — — — —
• Two tone color ................................................................... ✔ ✔ ✔ ✔ ✔ —
• Two-stage gas valve .......................................................... ✔ ✔ — — — —
• Non-prorated 20-year heat exchanger limited warranty ......... ✔ ✔ ✔ ✔ ✔ ✔
(Residential only)*
• 5-year limited warranty on parts* ......................................... ✔ ✔ ✔ ✔ ✔ ✔
1 Upflow only.
NOTE: Variable speed XV80 furnaces should not be twinned and are not approved for twinning applications.

For complete equipment / combination


selections and installation instructions, please FUR-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XV, XL, XT, XR, XB 80
Convertible Gas Furnaces
Airflow Directions:
Downflow models when placed in horizontal position provide left XV 80 XL 80 XT 80 XR 80 XR 80 XB 80
to right airflow. Upflow models when placed in horizontal position TUD-R-V-K TUD-R-K TUD1/TDD1 TUD1/TDD1 TUD-C-K TUE-TDE
provide right to left airflow.
TDD-R-V-F 2-Stg. TDD-R-F 1 Stage 1 Stage TDD-C-F 1 Stage
Table FUR-12-A — Optional Accessories Variable Speed 2 Stage High Efficiency 1 Stage
BAYBASE205 ........... Downflow subbase for ................................ ✔ ✔ ✔ ✔ ✔ ✔

PHASED OUT
downflow models only
BAYFLTR200 ............ Side Filter Rack (External) .......................... ✔ ✔ — TUD1 — —
BAYFLTR203 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔
for 17.5" cabinet
BAYFLTR204 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔
for 21" cabinet
BAYFLTR205 ............ Filter kit horiz conversion ............................ ✔ ✔ — — ✔ ✔
for 24.5" cabinet
BAYFLTR206 ............ Filter Access Door Kit ................................ ✔ ✔ TDD1 TDD1 ✔ ✔
BAYFLTR3171 ......... Cleanable filter for 14.5" ........................... — — ✔ ✔ — ✔
and 17.5" cabinet upflow only
BAYFLTR3211 ......... Cleanable filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔
21" cabinet upflow only
BAYFLTR3241 ......... Cleanable filter for .................................... ✔ ✔ ✔ ✔ ✔ ✔
24.5" cabinet upflow only
BAYLPKT210B ......... Propane conversion kit ............................... ✔ ✔ ✔ ✔ ✔ ✔
BAYLPSS210B ......... LP Kit with Stainless .................................. ✔ ✔ ✔ ✔ ✔ ✔
Steel Burners
BAYRACK960A235 . Filter Rack Kit for upflow ............................. TUD TUD ✔ ✔ TUD TUE
models only (internal)
BAYVENT800B4 ...... Masonry chimney vent kit ........................... ✔ ✔ ✔ ✔ — —
1 Contains one (1) high velocity filter.
2 Available for models with 1800 CFM or greater witch require an additional side return.
3 Upflow only.
4 TUD-C-J/TUD-R-J and later
5 Includes 17" Cleanable Filter.
NOTE: Variable Speed XV80 Furnaces should not be twinned and are not approved for twinning applications.

Special Use Furnace Accessories

Table FUR-12-B — High Altitude Pressure Switch 80%


Model Shipping
Number Description Used With Weight
BAYHALT248 1 Switch TUD-C-K/TDD-C-F.TUE-A-L/TDE-A-M, 2
TUD1, TDD1
BAYHALT249 1 Switch TUD-R-K,TDD-R-F 2

12
Table FUR-12-C — Dual Fuel Heat Pump Control Kit12
Model Number Case Height Used With
TAYPLUS103A ........... Heat Pump Control Kit ........... Gas, LP., Oil and Electric Furnaces
TAYSTAT250B ........... Outdoor Thermostat ............... TAYPLUS103A for Restricted Mode
THT1248 ..................... Bonnet Switch ........................ Oil Furnaces Only (Order Separately)
Bonnet TAYPLUS103A 1 Factory wired for non-restricted mode, can be wired for restricted mode.
Switch 2 Applicable for all furnaces with 35 VA or larger low voltage transformer (separate high voltage power not required).

For complete equipment / combination


Effective 1/1/06 FUR-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
XV80 Variable Speed
High Efficiency Oil Furnaces

TLF -
TDF - Lowboy Front THV -
Downflow/Horizontal Flue (TLR not shown) Highboy Vertical
• Up to 82.7% Annual Fuel Utilization Efficiency • Slide out blower assembly for quick • Recessed door handles for easy removal of
(AFUE) cleaning and service accessibility Highboy & lowboy Furnace doors
• 13 gauge hot rolled steel wrap around heat • Filter rack with cleanable filter (Highboy & • Lowboy models available with front or rear
exchanger for durability Lowboy Models) except Downflow/ flue option
• Beckett Flame Retention Burner operates Horizontal • Highboy models with top or right side
cleanly and quietly • 5 year limited parts warranty venting
• Burner features include primary control with • Limited lifetime heat exchanger warranty • Downflow/Horizontal model field
interrupted ignition for reliability, pre-purge and • Preformed ceramic fiber convertible from Downflow to right or left
clean cutoff solenoid valve for smooth ignition combustion chamber for higher efficiencies horizontal
• Burner and controls factory wired and more complete combustion • 6” Left and Right side fresh air knockouts –
• Dual clean out ports for quick access and easy • 40 VA control transformer for add on Highboy and Lowboy Models
cleaning cooling • Barometric draft regulator included
• Insulated blower compartment • Heavy gauge, powder painted (two tone),
• Variable speed blower motor steel cabinet

Table FUR-13-A — Specifications:


Airflow Nominal Uncrated
Model In Tons Cap-BTUH ICS FLue Dimensions(In.) Mfg. Shipping
Number (Nom.) *Htg Output AFUE Size H W D Plant Weight
THV1M087A9V3SAA 3 87,000 82.4 6" 58 22.25 31 TR 260
THV1M087A9V5SAA 5 87,000 82.6 6" 58 22.25 31 TR 260
TLF1M087A9V3SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300
TLF1M087A9V5SAA 5 87,000 82.7 6" 41.5 22.25 47 TR 300
TLR1M087A9V3SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300
TLR1M087A9V5SAA 5 87,000 82.4 6" 41.5 22.25 47 TR 300
TDF1M087A9V5SAA 3 87,000 81.7 6" 22.25 61.25 22.25 TR 280
TDF1M087A9V5SAA 5 87,000 82.6 6" 22.25 61.25 22.25 TR 280
* Other input/output capacities are available by changing the burner nozzle. See installer's guide for details.

Table FUR-13-B — Accessories:


Mfg. Shipping
Model Description Used With Plant Weight
BAYSUB10ABASEAA Downflow Subbase TDF1M087A9V3, 9V5SAA TR 22
BAYTRM10AVENTAA Top Panel & Trim Ring THV1M087A9V3, 9V5SAA TR 1

For complete equipment / combination


selections and installation instructions, please FUR-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
XP80 High Efficiency Oil Furnaces

TLF -
TDF - Lowboy Front THV -
Downflow/Horizontal Flue (TLR not shown) Highboy Vertical
• Up to 82.4% Annual Fuel Utilization • Insulated blower compartment • Recessed door handles for easy removal of
Efficiency (AFUE) • Slide out blower assembly for quick cleaning Highboy & lowboy Furnace doors
• 13 gauge hot rolled steel wrap around heat and service accessibility • Lowboy models available with front or rear
exchanger for durability • Filter rack with washable filter (Highboy & flue option
• Beckett Flame Retention Burner operates Lowboy Models) except Downflow/Horizontal • Highboy models with top or right side
cleanly and quietly • 5 year parts limited warranty and lifetime heat venting
• Burner features include primary control with exchanger warranty • Downflow/Horizontal model field
interrupted ignition for reliability, pre-purge • Preformed ceramic fiber convertible from Downflow to right or left
and clean cutoff solenoid valve for smooth combustion chamber for higher efficiencies horizontal
ignition and more complete combustion • 6” Left and Right side fresh air knockouts –
• Burner and controls factory wired • 40 VA control transformer for add on cooling Highboy and Lowboy Models
• Dual clean out ports for quick access and • Heavy gauge, powder painted (two tone), • Barometric draft regulator included
easy cleaning steel cabinet
• Direct drive, permanently lubricated, 4
speed blower motor

Table FUR-14-A — Specifications:


Airflow Nominal Uncrated
Model In Tons Cap-BTUH ICS FLue Dimensions(In.) Mfg. Shipping
Number (Nom.) *Htg Output AFUE Size H W D Plant Weight
THV1M087A936SAA 3 87,000 82.4 6" 58 22.25 31 TR 260
THV1M087A948SAA 4 87,000 82.4 6" 58 22.25 31 TR 260
TLF1M087A936SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300
TLF1M087A948SAA 4 87,000 82.0 6" 41.5 22.25 47 TR 300
TLR1M087A936SAA 3 87,000 82.0 6" 41.5 22.25 47 TR 300
TLR1M087A948SAA 4 87,000 82.0 6" 41.5 22.25 47 TR 300
TDF1M087A936SAA 3 87,000 81.7 6" 22.25 61.25 22.25 TR 280
TDF1M087A948SAA 4 87,000 81.7 6" 22.25 61.25 22.25 TR 280
* Other input/output capacities are available by changing the burner nozzle. See installer's guide for details.

Table FUR-14-B — Accessories:


Mfg. Shipping
Model Description Used With Plant Weight
BAYSUB10ABASEAA Downflow Subbase TDF1M087A936, 948SAA TR 22
BAYTRM10AVENTAA Top Panel & Trim Ring THV1M087A936, 948SAA TR 1

For complete equipment / combination


Effective 1/1/06 FUR-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Upflow/Horizontal
90% Gas Furnace Quick Reference

Specifications:
Furnace Nom. Blower Flue Propane Outlet Return Air
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Air Bottom Side
Number2 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H D
UPFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT/NON DIRECT VENT TWO-STAGE
TUY060R9V3W 56,000 93.0 1275 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUY080R9V3W 73,000 92.5 1400 Var. Var. 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUY100R9V4W 93,000 93.0 1770 Var. Var. 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUY120R9V5W 112,000 92.5 1920 Var. Var. 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XL 90 DIRECT/NON-DIRECT VENT, TWO STAGE, 1 OR 2 PIPE, UPFLOW/HORIZONTAL CONDENSING GAS FURNACE
TUX060R936W 56,000 93.0 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX080R942W 73,000 92.5 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX100R948W 93,000 93.0 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUX120R960W 112,000 92.5 2261 4 3/4 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)
TUX1B040A9H21A 38,000 92.1 1052 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B060A9H31A 56,000 92.1 1248 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B080A9H31A 74,000 92.1 1320 4 1/2 2, 21/2, 3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1C100A9H41A 94,000 92.1 1737 4 3/4 21/2, 3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUX1D120A9H51A 113,000 92.1 2023 4 1.0 21/2, 3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE (115/1/60)
TUX1B040A9241A 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B060A9361A 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B080A9421A 74,000 92.1 1470 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1B080A9601A 76,000 92.1 2121 4 1/2 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX1C100A9481A 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUX1C100A9601A 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUX1D120A9601A 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGE
TUC040C924B 37,000 92.1 812 4 1/5 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUC060C936B 56,000 92.1 1196 4 1/3 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUC080C942B 74,000 92.1 1470 4 1/3 21/2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUC100C948B 94,000 92.1 1746 4 1/2 21/2–3 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUC100C960B 93,000 92.1 2165 4 1/2 21/2–3 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUC120C960B 113,000 92.1 2261 4 1/2 3 Only BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT/NON DIRECT VENT SINGLE STAGE
TUX040C924D 38,000 92.1 812 4 1/5 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX060C936D 56,000 92.1 1196 4 1/3 2–3 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUX080C942D
TUX080C960D
TUX100C948D
TUX100C960D
TUX120C960D
74,000
76,000
94,000
93,000
113,000
92.1
92.1
92.1
92.1
92.1
PHASED OUT
1470
2121
1746
2165
2261
4
4
4
4
4
1/3
1/2
1/2
1/2
1/2
2–3
2–3
1
2 /2–3
1
2 /2–3
3 Only
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
16.25
16.25
19.75
23.25
23.25
19.6
19.6
19.6
19.6
19.6
16
16
19
23
23
23.5
23.5
23.5
23.5
23.5
14.88
14.88
14.88
14.88
14.88
23.75
23.75
23.75
23.75
23.75
1 Isolated Combustion System.
2 CFM @ .5 inches ESP with filter in place.

For complete equipment / combination


selections and installation instructions, please FUR-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Downflow/Horizontal
90% Gas Furnace Quick Reference

Specifications:
Furnace Nom. Blower Flue Propane Outlet Return
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Downflow Air Air
Number Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H D
DOWNFLOW/HORIZONTAL — XV 90 VARIABLE SPEED WITH RECUPERATIVE CELL DIRECT VENT TWO-STAGE
TDY060R9V3W 56,000 92.0 1350 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDY080R9V3W 74,000 92.5 1210 Var. Var. 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDY100R9V4W 94,000 93.0 1800 Var. Var. 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDY120R9V5W 112,000 92.5 1900 Var. Var. 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL— XL 90 NON-DIRECT VENT, TWO STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDX060R936W 55,000 92.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX080R942W 74,000 92.5 1323 4 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX100R948W 93,000 93.0 1614 4 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDX120R960W 111,000 92.5 1939 4 3/4 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XT 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDX1B040A9H31A 38,000 91.0 1043 4 1/2 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B060A9H31A 56,000 91.0 1223 4 1/2 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B080A9H31A 74,000 91.0 1423 4 3/4 2, 21/2, 3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
1
TDX1C100A9H41A 94,000 91.0 1700 4 3/4 2 /2, 3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
1
TDX1D120A9H51A 112,000 91.0 2006 4 1.0 2 /2, 3 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XR 90 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDX1B040A9241A 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B060A9361A 56,000 91.0 1209 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1B080A9421A 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX1C100A9481A 94,000 91.0 1614 3 1/2 21/2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDX1D120A9601A 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XB 90 WITH RECUPERATIVE COIL SINGLE STAGE
1
TDC040C924B 38,000 91.0 807 4 1/5 2 /2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDC060C936B 56,000 91.0 1082 4 1/3 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDC080C942B 74,000 91.0 1323 3 1/2 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDC100C948B 93,000 91.0 1614 3 1/2 2–3 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDC120C960B 112,000 91.0 1939 3 1/2 3 Only BAYLPKT210B BAYBASE205 23.0 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XR 90 WITH RECUPERATIVE COIL DIRECT VENT SINGLE STAGE
TDX040C924D 38,000 91.0 807 4 1/5 2–3 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDX060C936D
TDX080C942D
TDX100C948D
TDX120C960D
56,000
74,000
94,000
112,000
1 Isolated Combustion System.
91.0
91.0
91.0
91.0
PHASED OUT
1209
1323
1614
1939
4
3
3
3
1/3
1/2
1/2
1/2
2–3
2–3
21/2–3
3 Only
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYLPKT210B
BAYBASE205
BAYBASE205
BAYBASE205
BAYBASE205
16
16
19.5
23
19.6
19.6
19.6
19.6
16.25
16.25
19.75
23.25
19.6
19.6
19.6
19.6

2 CFM @ .5 inches ESP with filter in place.

For complete equipment / combination


Effective 1/1/06 FUR-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Upflow/Horizontal
80% Gas Furnace Quick Reference
Specifications:
Furnace Nom. Blower Flue Propane Outlet Return Air
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Air Bottom Side
Number2 Output AFUE Airflow Taps H.P. (in.) Kit W D W D H D
UPFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO-STAGE
TUD060R9V3K 48,000 80.0 1402 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080R9V3K 64,000 80.0 1410 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080R9V4K 64,000 80.0 1591 Var. Var. 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD100R9V3K 80,000 80.0 1251 Var. Var. 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD100R9V5K 79,000 80.0 2100 Var. Var. 4 BAYLPKT210B 19.75 19.6 19 23.5 14.88 23.75
TUD120R9V5K 97,000 80.0 2019 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD140R9V5K 112,000 80.0 2075 Var. Var. 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XL 80 INDUCED DRAFT TWO-STAGE
TUD040R924K 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD060R936K 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD060R937K 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080R936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080R948K 63,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD100R936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD100R948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD100R960K 80,000 80.0 1978 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75
TUD100R961K 80,000 80.0 2175 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD120R954K 95,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD120R960K 95,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD140R960K 112,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TUD1A040A9H21A 32,000 80.0 1011 4 1/2 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD1B060A9H31A 47,000 80.0 1238 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1B080A9H31A 63,000 80.0 1318 4 1/2 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1C080A9H41A 64,000 80.0 1600 4 3/4 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD1B100A9H31A 79,000 80.0 1280 4 3/4 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1C100A9H51A 79,000 80.0 2038 4 1.0 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75
TUD1D120A9H51A 96,000 80.0 1996 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD1D140A9H51A 111,000 80.0 1984 4 1.0 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TUD1A040A9241A 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD1A040A9301A 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD1A060A9241A 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD1A060A9361A 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD1B060A9361A 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1B080A9241A 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1B080A9361A 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1B080A9481A 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1C080A9601A 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75
TUD1B100A9361A 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD1B100A9451A 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55
TUD1C100A9481A 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD1C100A9601A 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75
TUD1D100A9721A 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD1C120A9541A 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD1D120A9601A 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD1D140A9601A 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL— XB 80 INDUCED DRAFT SINGLE STAGE
TUE040A924L 31,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUE060A936L 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUE060A937L 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUE080A936L 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUE080A948L 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUE100A936L 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUE100A948L 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.25 19.6 19.5 23.5 14.88 23.75
TUE100A960L 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUE120A960L 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUE140A960L 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
UPFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGE
TUD040C924K 32,000 80.0 910 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD040C930K 32,000 80.0 1092 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD060C924K 47,000 80.0 901 4 1/5 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD060C936K 47,000 80.0 1236 4 1/3 4 BAYLPKT210B 13.25 19.6 13 23.5 14.88 23.75
TUD060C937K 47,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080C924K 64,000 80.0 956 4 1/5 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75

PHASED OUT
TUD080C936K 63,000 80.0 1296 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080C948K 64,000 80.0 1710 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD080C960K 64,000 80.0 2163 4 3/4 4 BAYLPKT210B 16.25 19.6 19.5 23.5 14.88 23.75
TUD100C936K 79,000 80.0 1363 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.75
TUD100C945K 80,000 80.0 1556 4 1/3 4 BAYLPKT210B 16.25 19.6 16 23.5 14.88 23.55
TUD100C948K 79,000 80.0 1669 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD100C960K 79,000 80.0 2001 4 1/2 4 BAYLPKT210B 19.75 19.6 23 23.5 14.88 23.75
TUD100C972K 80,000 80.0 2249 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD120C954K 96,000 80.0 2037 4 1/2 4 BAYLPKT210B 19.75 19.6 19.5 23.5 14.88 23.75
TUD120C960K 96,000 80.0 2005 4 1/2 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
TUD140C960K 111,000 80.0 2216 4 3/4 4 BAYLPKT210B 23.25 19.6 23 23.5 14.88 23.75
1 Isolated Combustion System. 2 CFM @ .5 inches ESP with filter in place.
For complete equipment / combination
selections and installation instructions, please FUR-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Downflow/Horizontal
80% Gas Furnace Quick Reference

Specifications:
Furnace Nom. Blower Flue Propane Outlet Return
Model BTUH ICS1 Max.2 Speed Motor Size Conversion Downflow Air Air
Number Output AFUE Airflow Taps H.P. (in.) Kit Subbase W D H D
DOWNFLOW/HORIZONTAL — XV 80 VARIABLE SPEED TWO STAGE
TDD060R9V3F 48,000 80.0 1360 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD080R9V3F 63,000 80.0 1315 Var. Var. 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100R9V5F 81,000 80.0 2015 Var. Var. 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120R9V5F 95,000 80.0 2215 Var. Var. 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XL 80 TWO-STAGE INDUCED DRAFT
TDD040R924F 32,000 80.0 960 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060R936F 47,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060R937F 47,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD080R936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100R945F 79,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100R948F 79,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD100R960F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120R960F 94,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
TDD140R960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XT 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDD1B060A9H31A 48,000 80.0 1309 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B080A9H31A 64,000 80.0 1314 4 1/2 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1C100A9H51A 81,000 80.0 2007 4 1.0 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1D120A9H51A 96,000 80.0 2010 4 1.0 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/ HORIZONTAL- XR 80 DIRECT/NON-DIRECT VENT, SINGLE-STAGE, ONE OR TWO PIPE, CONDENSING GAS FURNACE
TDD1A040A9241A 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD1A060A9241A 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD1A060A9361A 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD1B060A9361A 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B080A9361A 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B080A9451A 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1B100A9451A 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD1C100A9481A 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1C100A9541A 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1C120A9541A 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD1D120A9601A 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
TDD1D140A9601A 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XB 80 INDUCED DRAFT SINGLE STAGE
TDE060A936M 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDE060A937M 48,000 80.0 1281 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDE080A945M 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDE100A945M 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDE100A960M 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDE120A960M 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
DOWNFLOW/HORIZONTAL — XR 80 INDUCED DRAFT SINGLE STAGE
TDD040C924F 31,000 78.0 920 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060C924F 48,000 80.0 1001 4 1/5 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060C936F 48,000 80.0 1282 4 1/3 4 BAYLPKT210B BAYBASE205 13 19.6 13.25 19.6
TDD060C937F 48,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6

PHASED OUT
TDD080C936F 64,000 80.0 1369 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD080C945F 64,000 80.0 1575 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100C945F 80,000 80.0 1546 4 1/3 4 BAYLPKT210B BAYBASE205 16 19.6 16.25 19.6
TDD100C948F 80,000 80.0 1740 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD100C954F 81,000 80.0 1929 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120C954F 96,000 80.0 1918 4 1/2 4 BAYLPKT210B BAYBASE205 19.5 19.6 19.75 19.6
TDD120C960F 96,000 80.0 2049 4 1/2 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
TDD140C960F 113,000 80.0 2133 4 3/4 4 BAYLPKT210B BAYBASE205 23 19.6 23.25 19.6
1 Isolated Combustion System.
2 CFM @ .5 inches ESP with filter in place.

For complete equipment / combination


Effective 1/1/06 FUR-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
High Efficiency
Split System – Cased
Heat Pump and Cooling Coils
Table FUR-19-A — Aluminum High Efficiency Coils (Upflow/Downflow/Horizontal Left) R-22 Refrigerant
Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
UP 2TXCB025AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 17.5 x 17.5 x 21.5 42 /85 3
/8
LEFT 3 WAY
COIL
2TXCB031AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 22.5 x 17.5 x 21.5 54 /87 3
/8
ComfortTM coil
DOWN 2TXCB036AS3HCA 36,000 A TXV-NB1 155/8 x 193/8 26.88 x 17.5 x 21.5 67 7
/8 3
/8
2TXCC037AS3HCA 36,000 A TXV-NB1 191/8 x 193/8 26.88 x 21 x 21.5 70 7
/8 3
/8
2TXCC054AS3HCA 54,000 A TXV-NB1 191/8 x 193/8 30 x 21 x 21.5 73 11/8 3
/8
2TXCD065AS3HCA 60,000 A TXV-NB1 225/8 x 193/8 33* x 24.5 x 21.5 90 11/8 3
/8
2/4TXC Comfort™
Coil Features: Table FUR-19-B — Aluminum High Efficiency Coils (Upflow/Downflow/Horizontal Left) R-410A Refrigerant
• All Aluminium coil to reduce Nom. Cap. Outlet Overall Shipping Line Size
formicary corrosion Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• All Non-Bleed TXV valves Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
with internal check valve for 4TXCB025AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 17.5 x 17.5 x 21.5 42 5
/8 3
/8
heat pump operation 4TXCB031AS3HCA 30,000 A TXV-NB1 155/8 x 193/8 22.5 x 17.5 x 21.5 54 7
/8 3
/8
• Split inner and outer doors
for easy coil cleaning 4TXCB036AS3HCA 36,000 A TXV-NB1 155/8 x 193/8 26.88 x 17.5 x 21.5 67 7
/82 3
/8
• Double sloped non corrosive 4TXCC037AS3HCA 36,000 A TXV-NB1 191/8 x 193/8 26.88 x 21 x 21.5 70 7
/8 3
/8
drain pans- UL Rated 400°F 4TXCC054AS3HCA 54,000 A TXV-NB1 191/8 x 193/8 30 x 21 x 21.5 73 11/83 3
/8
• Suction pressure service 4TXCD065AS3HCA 60,000 A TXV-NB1 225/8 x 193/8 33* x 24.5 x 21.5 90 11/83 3
/8
port
• 100% foil faced insulation
• Easy case attachment to Table FUR-19-C —Cased Horizontal Flat Coil R-22 Refrigerant
furnace Nom. Cap. Outlet Overall Shipping Line Size
• 3 way application Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Painted cabinet matches Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
5 1
furnace 2TXFH018AS3HHA 18,000 Flat TXVNB1 24 x 21 22 x 10 x 28 40 /8 /4
• 10 Year limited parts 2TXFH033AS3HHA 34,000 Flat TXVNB1 24 x 21 22 x 10 x 28 46 /43 5
/16
warranty on all Aluminium 2TXFH041AS3HHA 44,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 56 7
/8 3
/8
coils 2TXFH054AS3HHA 58,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 64 11/8 3
/8
TXF Features: 2TXFH063AS3HHA 61,000 Flat TXVNB1 331/4 x 27 28 x 10 x 37 79 11/8 3
/8
• Bi-directional airflow
• Sloped non corrosive drain pan
• HP TXV with mechanical
Table FUR-19-D —Cased Horizontal Flat Coil R-410A Refrigerant
fittings Nom. Cap. Outlet Overall Shipping Line Size
• Galvanized steel cabinet Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• 100% foil lined insulation Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
1 1
4TXFH018AS3HHA 18,000 Flat TXVNB1 24 x 21 22 x 10 x 28 40 /2 /4
3 5
4TXFH033AS3HHA 34,000 Flat TXVNB1 24 x 21 22 x 10 x 28 46 /4 /16
FURNACE

4TXFH041AS3HHA 44,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 56 3


/4 3
/8
AIRFLOW
4TXFH054AS3HHA 58,000 Flat TXVNB1 331/4 x 21 22 x 10 x 37 64 7
/8 3
/8
4TXFH063AS3HHA 61,000 Flat TXVNB1 331/4 x 27 28 x 10 x 37 79 7
/8 3
/8
FURNACE

AIRFLOW
Table FUR-19-E — Reversible, Cased Heat Pump/Cooling Coils — (Upflow/Downflow Horizontal Left
or Right) R-22 Refrigerant
Reversible Features: Nom. Cap. Maximum Outlet Overall Shipping Line Size
• Bi-Directional Airflow Model Cooling Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Same side service access for Number (Btuh) (CFM**) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
Horizontal Right or Left 2TXCA024AC3HMA 24,000 1000 A TXVNB1 125/8 x 193/8 30 x 14.5 x 21.5 1000 3
/4 5
/16
applications 2TXCB036AC3HMA 36,000 1200 A TXVNB1 155/8 x 193/8 30 x 17.5 x 21.5 1200 7
/8 3
/8
• Eliminates need for field 1 Start Kits may be required on outdoor unit.
installed Horizontal Drip 2 7/8 x 3/4 reducing coupling shipped with R-410A model coil.
Tray!!! 3 11/8 x 7/8 reducing coupling shipped with R-410A model coil.
• Fully Convertible - Upflow, *Overall height. Actual height of case is 30".
Downflow, Left or Right **Water Blowoff may occur if Maximum Cooling airflow is exceeded.
• Heat Pump and Cooling
Compatible
• Suction service port
• 100% foil lined insulation
• Split inner and outer doors for
easy coil cleaning
• Double sloped non-corrosive
drain pan - UL rated 400°F
• 5 year limited parts warranty
on all coils
• Non-Bleed TXV with
mechanical fittings
For complete equipment / combination
selections and installation instructions, please FUR-19 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System – Cased
Heat Pump and Cooling Coils

Table FUR-20-A — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-22 Refrigerant
Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
2TXCA018AC3HCA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 34 5
/8 1
/4
2TXCA024AC3HCA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 37 3
/4 5
/16
Comfort TM coil
2TXCB025AC3HCA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3
/4 5
/16
2TXCB031AC3HCA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 46 3
/4 5
/16
2TXCB036AC3HCA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 54 7
/8 3
/8
2TXCC037AC3HCA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7
/8 3
/8
2TXCB042AC3HCA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 59 7
/8 3
/8
TXC Comfort™ 2TXCC043AC3HCA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3
/8
Coil Features: 2TXCB048AC3HCA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 71 11/8 3
/8
2TXCC049AC3HCA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3
/8
• HP TXV Mechanical 2TXCD050AC3HCA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3
/8
Fittings (2/4 TXC) 2TXCC060AC3HCA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 74 11/8 3
/8
• Split inner and outer doors 2TXCD061AC3HCA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 77 11/8 3
/8
for easy coil cleaning
• Double sloped non Table FUR-20-B — Cased Coil Convertible (Upflow/ Downflow/ Horizontal Left) R-410A Refrigerant
corrosive drain pans- Nom. Cap. Outlet Overall Shipping Line Size
UL Rated 400°F Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Suction pressure service Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
5 3 5 1
port 4TXCA018AC3HCA 18,000 A TXVNB1 12 /8 x 19 /8 17.6 x 14.5 x 21.5 34 /8 /4
5 3 3 5
• 100% foil lined insulation 4TXCA024AC3HCA 24,000 A TXVNB 1 12 /8 x 19 /8 22.6 x 14.5 x 21.5 37 /4 /16
• Easy case attachment to 4TXCB025AC3HCA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3
/4 5
/16
furnace 4TXCB031AC3HCA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 46 3
/4 5
/16
• 3 way application 4TXCB036AC3HCA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 54 7
/8 3
/8
• Painted cabinet matches 4TXCC037AC3HCA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7
/8 3
/8
furnace 4TXCB042AC3HCA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 59 7
/8 3
/8
• 5 year limited parts 4TXCC043AC3HCA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3
/8
warranty 4TXCB048AC3HCA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 71 11/8 3
/8
• Copper tube Aluminum fin 4TXCC049AC3HCA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3
/8
4TXCD050AC3HCA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3
/8
4TXCC060AC3HCA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 74 11/8 3
/8
4TXCD061AC3HCA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 77 11/8 3
/8

Split System – Cased


Comfort TM coil
Cooling Only Coils
Table FUR-20-C — Cooling Only Cased (Upflow/ Downflow) R-22 Refrigerant
Nom. Cap. Outlet Overall Shipping Line Size
2/4CXC Coil Features: Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Cased and uncased Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
upflow /downflow cooling 2CXCA018AC3CUA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 32 5
/8 1
/4
only coils 2CXCA024AC3CUA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 34 3
/4 5
/16
• Brazed fittings (left side) 2CXCB025AC3CUA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 42 3
/4 5
/16
• Drain fitting (left side) 2CXCB031AC3CUA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 44 3
/4 5
/16
• Non-Bleed TXV with 2CXCB036AC3CUA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 44 7
/8 3
/8
mechanical fittings. 2CXCC037AC3CUA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7
/8 3
/8
• Copper tube with 2CXCB042AC3CUA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 52 7
/8 3
/8
Aluminum fins
2CXCC043AC3CUA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3
/8
• Painted coil case
2CXCB048AC3CUA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 58 11/8 3
/8
• Suction pressure service
port 2CXCC049AC3CUA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3
/8
• 100% foil lined insulation 2CXCD050AC3CUA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3
/8
• Split inner and outer doors 2CXCC060AC3CUA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 70 11/8 3
/8
for easy coil cleaning 2CXCD061AC3CUA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 72 11/8 3
/8
• 5 Year limited parts 1 Start Kits may be required on outdoor unit.
warranty
For complete equipment / combination
Effective 1/1/06 FUR-20 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System - Cased/Uncased
Cooling Only Coils

Table FUR-21-A — Cooling Only Cased (Upflow/ Downflow) R-410A Refrigerant


Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
4CXCA018AC3CUA 18,000 A TXVNB1 125/8 x 193/8 17.6 x 14.5 x 21.5 32 5
/8 1
/4
4CXCA024AC3CUA 24,000 A TXVNB1 125/8 x 193/8 22.6 x 14.5 x 21.5 34 3
/4 5
/16
4CXCB025AC3CUA 24,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5x 21.5 42 3
/4 5
/16
Comfort TM coil
4CXCB031AC3CUA 30,000 A TXVNB1 155/8 x 193/8 17.6 x 17.5 x 21.5 44 3
/4 5
/16
4CXCB036AC3CUA 36,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 44 7
/8 3
/8
4CXCC037AC3CUA 37,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 53 7
/8 3
/8
4CXCB042AC3CUA 42,000 A TXVNB1 155/8 x 193/8 22.6 x 17.5 x 21.5 52 7
/8 3
/8
4CXCC043AC3CUA 43,000 A TXVNB1 191/8 x 193/8 22.6 x 21 x 21.5 56 11/8 3
/8
2/4CXC Coil Features: 4CXCB048AC3CUA 48,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 58 11/8 3
/8
• Cased and uncased 4CXCC049AC3CUA 48,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 67 11/8 3
/8
upflow /downflow cooling 4CXCD050AC3CUA 48,000 A TXVNB1 225/8 x 193/8 26.9 x 24.5 x 21.5 77 11/8 3
/8
only coils
4CXCC060AC3CUA 60,000 A TXVNB1 191/8 x 193/8 30.1 x 21 x 21.5 70 11/8 3
/8
• Brazed fittings (left side)
4CXCD061AC3CUA 60,000 A TXVNB1 225/8 x 193/8 30.1 x 24.5 x 21.5 72 11/8 3
/8
• Drain fitting (left side)
• Non-Bleed TXV with
mechanical fittings.
Table FUR-21-B — Cooling Only Uncased Coils (Upflow/ Downflow) R-22 Refrigerant
• Copper tube with Nom. Cap. Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Weight OD OD
Aluminum fins Number (Btuh) Type Control H x W x D (Ibs.) Gas Liq.
• Painted coil case
• Suction pressure service 2CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5
/8 1
/4
port 2CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3
/4
5
/16
• 100% foil lined insulation 2CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3
/4 5
/16
• Split inner and outer doors 2CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3 5
/4 /16
for easy coil cleaning 2CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7
/8 3
/8
• 5 Year limited parts 2CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7
/8 3
/8
warranty 2CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7
/8 3
/8
2CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 11/8 3
/8
2CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 11/8 3
/8
2CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 11/8 3
/8
2CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 11/8 3
/8
2CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 11/8 3
/8
2CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 11/8 3
/8

Table FUR-21-C — Cooling Only Uncased Coils (Upflow/ Downflow) R-410A Refrigerant
Nom. Cap. Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Weight OD OD
Number (Btuh) Type Control H x W x D (Ibs.) Gas Liq.
4CXAA018AC3CUA 18,000 A TXVNB1 15.9 x 13.3 x 21.1 17 5
/8 1
/4
4CXAA024AC3CUA 24,000 A TXVNB1 17.6 x 13.3 x 21.1 20 3
/4 5
/16
4CXAB025AC3CUA 24,000 A TXVNB1 15.9 x 16.3 x 21.1 21 3
/4 5
/16
4CXAB031AC3CUA 30,000 A TXVNB1 15.9 x 16.3 x 21.1 26 3
/4 5
/16
4CXAB036AC3CUA 36,000 A TXVNB1 21.2 x 16.3 x 21.1 26 7
/8 3
/8
4CXAB042AC3CUA 42,000 A TXVNB1 21.2 x 16.3 x 21.1 31 7
/8 3
/8
2/4CXA Coil Features:
• Uncased upflow /downflow 4CXAB048AC3CUA 48,000 A TXVNB1 25.3 x 16.3 x 21.1 36 7 3
/8 /8
4CXAC037AC3CUA 36,000 A TXVNB1 20.8 x 19.8 x 21.1 27 11/8 3
/8
cooling only coils
4CXAC043AC3CUA 42,000 A TXVNB1 20.8 x 19.8 x 21.1 32 11/8 3
/8
• Brazed fittings (left side)
• Drain fitting (left side) 4CXAC049AC3CUA 48,000 A TXVNB1 24.9 x 19.8 x 21.1 34 11/8 3
/8
4CXAC060AC3CUA 60,000 A TXVNB1 29.1 x 19.8 x 21.1 40 11/8 3
/8
• Non-Bleed TXV with
4CXAD050AC3CUA 48,000 A TXVNB1 25.1 x 23.3 x 21.1 37 11/8 3
/8
mechanical fittings.
• Copper tube with Aluminum 4CXAD061AC3CUA 60,000 A TXVNB1 28.6 x 23.3 x 21.1 42 11/8 3
/8
1 Start Kits may be required on outdoor unit.
fins
• Suction pressure service
port
• Split inner for easy coil
cleaning
• 5 Year limited parts
warranty

For complete equipment / combination


selections and installation instructions, please FUR-21 Effective 1/1/06
refer to Product Data and/or Installers Guides.
High Efficiency
Split System – Cased/Uncased
Heat Pump and Cooling Coils
Table FUR-22-A — Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow or
Horizontal Left Only) R-22 Refrigerant
Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
TXC031S3HPC 30,000 A TXVNB1 155/8 x 193/8 22.5 x 17.5 x 21.5 54 3
/4 5
/16
TXC036S3HPD 36,000 A TXVNB1 155/8 x 193/8 26.9 x 17.5 x 21.5 67 7
/8 3
/8
TXC037S3HPD 36,000 A TXVNB1 191/8 x 193/8 26.9 x 21 x 21.5 70 7
/8 3
/8
TXC054S3HPC 54,000 A TXVNB1 191/8 x 193/8 30.0 x 21 x 21.5 73 11/8 3
/8
TXC065S3HPC 60,000 A TXVNB1 225/8 x 1911/16 33.0* x 24.5 x 21.5 90 11/8 3
/8

Table FUR-22-B — Brazed, Cased Dual Circuit Cooling Only Coils-(Upflow, Downflow or Horizontal Left Only)
Nom. Cap. Outlet Overall Shipping Line Size
TXC Comfort™ Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Coil Features: Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
• Split inner and outer doors TXC039E300C2 36,000 A TXVNB1 155/8 x 195/16 301/16 x 171/2 x 211/2 69 3
/4 5
/16
for easy coil cleaning TXC059E300C2 59,000 A TXVNB1 191/8 x 195/16 301/16 x 21 x 211/2 73 7
/8 3
/8
• Double sloped non
TXC062E300C2 64,000 A TXVNB1 225/8 x 195/16 301/16 x 241/2 x 211/2 79 7
/8 3
/8
corrosive drain pans-
UL Rated 400°F 1 Start Kits may be required on outdoor unit.
• Suction pressure service 2 Only used with Variable Speed Gas Furnace to achieve 2-stage heat/cool.
*Overall height. Actual height of case is 30".
port
• 100% foil lined insulation
Table FUR-22-C — Comfort™ Coils Brazed Coils* (Upflow/Downflow/Horizontal Left Only)
• Easy case attachment to
R-410A Refrigerant
furnace
Nom. Cap. Outlet Uncrated Shipping Line Size
• 3 way application Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• Painted cabinet matches Number (Btuh) Type Control Cased W/H x D H x W x D (Ibs.) Gas Liq.
furnace
• 5 Year limited parts RXC025S3HPD 24,000 A TXVNB1 Full 155/8 x 195/16 175/8 x 171/2 x 211/2 42 5
/8 5
/16
warranty on all coils RXC031S3HPC 30,000 A TXVNB1 Full 155/8 x 195/16 225/8 x 171/2 x 211/2 54 3
/4 5
/16
• Copper tube and RXC036S3HPD 36,000 A TXVNB1 Full 155/8 x 195/16 267/8 x 171/2 x 211/2 67 3
/4 3
/8
Aluminum fin RXC037S3HPD 36,000 A TXVNB1 Full 191/8 x 195/16 267/8 x 21 x 211/2 70 3
/4 3
/8
RXC ComfortTM Coil RXC054S3HPC 54,000 A TXVNB1 Full 191/8 x 195/16 301/16 x 21 x 211/2 73 7
/8 3
/8
Features RXC061S3HPC 60,000 A TXVNB1 Full 2211/16 x 195/16 301/16 x 241/2 x 211/2 77 7
/8 3
/8
• Refrigerant R-410A only RXC065S3HPC 60,000 A TXVNB1 Partial 225/8 x 195/16 2337/8 x 241/2 x 211/2 94 7
/8 3
/8
• Split inner and outer
doors for easy coil
Table FUR-22-D — Brazed Uncased Coils* (Upflow/Downflow) R-410A Refrigerant
cleaning
Nom. Cap. Uncrated Line Size
• Double sloped non- Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
corrosive drain pans Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
(UL Rated 400oF)
• Suction pressure RXA060S3HPC 60,000 A TXVNB1 None 28 x 199/16 x 199/16 46 3
/4 3
/8
3 3
service port RXA061S3HPC 60,000 A TXVNB1 None 277/16 x 234/16 x 199/16 47 /4 /8
• 100% foil lined insulation 1 Start Kits may be required on outdoor unit.
• Easy case attachment 2 Overall height. Actual height of case is 30". Downflow application of RXC065 requires field fabrication of case extension shown in
to furnace the Installer's Guide.
• Painted cabinet matches Note: RXC, RXA and RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing
furnace recommended with R-410A systems
• 3 way application
• 5-year limited parts Table FUR-22-E — Brazed, Cased Dual Circuit Cooling Only Coil23
warranty Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
RXA ComfortTM Coil
TXE120B500D 120,000 Flat TXV-B 183/4 x 573/4 26 x 64 x 25 235 11/8 3
/8
Features
1 Start Kits may be required on outdoor unit.
• Double sloped non-
2 Coils are 3/8" cu/al plate fin.
corrosive drain pan 3 Two circuit cooling coil.
(UL Rated 400oF)
• Suction pressure
service port
• Easy access service
panels
• 5-year limited parts
warranty

For complete equipment / combination


Effective 1/1/06 FUR-22 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System – Cased
Heat Pump and Cooling Coils

Table FUR-23-A — Brazed, Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left Only*)
Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
TXC018C4HPC 18,000 A .049 125/8 x 193/8 175/8 x 141/2 x 211/2 32 5
/8 1
/4
TXC024C4HPC 24,000 A .049 125/8 x 193/8 175/8 x 141/2 x 211/2 34 3
/4 5
/16
TXC025C4HPC 24,000 A .057 155/8 x 193/8 175/8 x 171/2 x 211/2 39 3
/4 5
/16
TXC030C4HPC 30,000 A .067 125/8 x 193/8 225/8 x 141/2 x 211/2 37 3
/4 5
/16
TXC031C4HPC 31,000 A .067 155/8 x 193/8 175/8 x 171/2 x 211/2 43 3
/4 5
/16

PHASED OUT
TXC035C4HPC 35,000 A .071 125/8 x 193/8 225/8 x 141/2 x 211/2 37 7
/8 3
/8
TXC036C4HPC 36,000 A .071 155/8 x 193/8 225/8 x 171/2 x 211/2 51 7
/8 3
/8
TXC037C4HPC 37,000 A .071 191/8 x 193/8 225/8 x 21 x 211/2 54 7
/8 3
/8
TXC042C4HPC 42,000 A .080 155/8 x 193/8 225/8 x 171/2 x 211/2 56 7
/8 3
/8
1 – 5 Ton TXC043C4HPC 43,000 A .080 191/8 x 193/8 225/8 x 21 x 211/2 57 11/8 3
/8
Cased Coils TXC048C4HPD 48,000 A .083 155/8 x 193/8 267/8 x 171/2 x 211/2 68 11/8 3
/8
• Split inner and outer TXC049C4HPD 48,000 A .083 191/8 x 193/8 267/8 x 21 x 211/2 69 11/8 3
/8
doors for easy coil TXC050C4HPD 48,000 A .083 225/8 x 195/16 267/8 x 241/2 x 211/2 69 11/8 3
/8
cleaning TXC060C5HPC 60,000 A TXV-B 191/8 x 193/8 301/16 x 21 x 211/2 69 11/8 3
/8
• Double sloped non TXC061C5HPC 61,000 A TXV-B 225/8 x 195/16 301/16 x 241/2 x 211/2 71 11/8 3
/8
corrosive drain pans-
UL Rated 400° F Table FUR-23-B —Brazed, Cased High Efficiency Heat Pump/Cooling Coils-(Upflow, Downflow or
• Suction pressure service Horizontal Left Only*)
port Nom. Cap. Outlet Overall Shipping Line Size
• 100% foil lined insulation Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• External FCCV location Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.

PHASED OUT
• Easy case attachment to TXC031E5HPC 30,000 A TXV-B 155/8 x 193/8 225/8 x 171/2 x 211/2 54 3
/4 5
/16
furnace TXC036E5HPD 36,000 A TXV-B 155/8 x 193/8 267/8 x 171/2 x 211/2 67 7
/8 3
/8
• 3 way application TXC037E5HPD 37,000 A TXV-B 191/8 x 193/8 267/8 x 21 x 211/2 70 7
/8 3
/8
• Painted cabinet matches TXC054E5HPC 54,000 A TXV-B 191/8 x 193/8 301/16 x 21 x 211/2 73 11/8 3
/8
furnace
• 5 year limited parts Table FUR-23-C — Brazed,Cased Heat Pump/Cooling Coils-(Upflow, Downflow or Horizontal Left or Right)
warranty on all coils Nom. Cap. Outlet Overall Shipping Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Weight OD OD
• FCCV equipped coils Number (Btuh) Type Control W/H x D H x W x D (Ibs.) Gas Liq.
compatible with R-22 or
R-410A refrigerant TXC024D4HPC 24,000 A .057 125/8 x 193/8 301/16 x 141/2 x 211/2 42 3
/4 5
/16
TXC025D4HPC 24,000 A .057 155/8 x 193/8 301/16 x 171/2 x 211/2 48 3
/4 5
/16

PHASED OUT
• Upflow, downflow or
horizontal left only TXC030D4HPC 30,000 A .067 125/8 x 193/8 301/16 x 141/2 x 211/2 46 3
/4 5
/16
(TXC-E/TXC-S) TXC031D4HPC 30,000 A .067 155/8 x 193/8 301/16 x 171/2 x 211/2 52 3
/4 5
/16
TXC035D4HPC 35,000 A .071 125/8 x 193/8 301/16 x 141/2 x 211/2 46 7
/8 3
/8
TXC036D4HPC 36,000 A .071 155/8 x 193/8 301/16 x 171/2 x 211/2 60 7
/8 3
/8
* TXC series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410A
systems.

RXH ComfortTM Coil Table FUR-23-D — Horizontal Only Cased Coil* R-410A Refrigerant
Features Nom. Cap. Uncrated Line Size
• Sloped non-corrosive Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
drain pan (UL Rated Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
400oF) PHASED
RXH063S3HPB 63,500 OUT
Flat PHASED
TXVNB1 OUT 28PHASED
Full 3
/4 x 101/4 x 371OUT
/2 79PHASED
3
/4 OUT
3
/8
• Bi-directional airflow
• Galvanized case - Table FUR-23-E — Cased Horizontal Only
unpainted Nom. Cap. Duct Con. Uncrated Line Size
• Suction pressure port Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Shipping OD OD
• 5-year limited parts Number (Btuh) Type Control H xW H x W x D Weight (Ibs.) Gas Liq.
warranty TXH025A4HPA 27,000 Flat .057 21 x 24 22 x 10 x 28 40 3
/4 5
/16

PHASED OUT
3 3
TXH033A4HPA 34,000 Flat .057 21 x 24 22 x 10 x 28 46 /4 /8
TXH041A4HPA 44,000 Flat .067 21 x 331/4 22 x 10 x 37 56 7
/8 3
/8
TXH054A4HPA 58,000 Flat .083 21 x 331/4 22 x 10 x 37 64 7
/8 3
/8
TXH063P3HPB 61,000 Flat TXVNB1 27 x 331/4 28 x 10 x 37 79 7
/8 3
/8
1 Start Kits may be required on outdoor unit.
* RXH series coils include a reducing coupling to accept the smaller interconnecting suction line tubing recommended with R-410A
systems.

For complete equipment / combination


selections and installation instructions, please FUR-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Split System – Cased/Uncased
Heat Pump and Cooling Coils

Table FUR-24-A — Brazed, Uncased Heat Pump/Cooling Coils (Upflow/Downflow)


Nom. Cap. Uncrated Line Size
Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
TXA018C4HPC 18,000 A .049 No 155/16 x 131/16 x 199/16 15 5
/8 1
/4
TXA024C4HPC 24,000 A .049 No 165/8 x 131/16 x 199/16 18 3
/4 5
/16
TXA025C4HPC 24,000 A .057 No 151/8 x 161/16 x 199/16 20 3
/4 5
/16
TXA030C4HPC 30,000 A .067 No 193/4 x 131/16 x 199/16 23 3
/4 5
/16
TXA031C4HPC 30,000 A .067 No 16 x 161/16 x 199/16 24 3
/4 5
/16
TXA035C4HPC 35,000 A .071 No 193/4 X 131/16 X 199/16 23 7
/8 5
/16

PHASED OUT
1 – 5 Ton TXA036C4HPC 36,000 A .071 No 191/8 x 161/16 x 199/16 29 7
/8 3
/8
Uncased Coils TXA037C4HPC 36,000 A .071 No 189/16 x 199/16 x 199/16 29 7
/8 3
/8
• 5-year limited parts TXA042C4HPC 42,000 A .080 No 211/4 x 161/16 x 199/16 34 7
/8 3
/8
warranty TXA043C4HPC 42,000 A .080 No 2011/16 x 199/16 x 199/16 32 7
/8 3
/8
• FCCV equipped coils TXA048C4HPC 48,000 A .083 No 255/16 x 161/16 x 199/16 39 11/8 3
/8
compatible with R-22 or TXA049C4HPC 48,000 A .083 No 247/8 x 199/16 x 199/16 37 11/8 3
/8
R-410A refrigerant TXA050C4HPC 48,000 A .083 No 243/8 x 231/16 x 199/16 38 11/8 3
/8
TXA060C5HPC 60,000 A TXV - B No 28 x 199/16 x 199/16 43 11/8 3
/8
TXA061C5HPC 60,000 A TXV - B No 277/16 x 231/16 x 199/16 44 11/8 3
/8

Table FUR-24-B — Brazed Cased (Upflow Only)


Nom. Cap. Outlet Uncrated Line Size
Model Cooling Coil Refrigerant Dim. (in.) Dim. (in.) Shipping OD OD
Number (Btuh) Type Control H xW H x W x D Weight (Ibs.) Gas Liq.
CCBA18A4ACD 18,000 A FIXED 125/8 x 193/8 175/8 x 141/2 x 211/2 30 5
/8 5
/16
CCBA24A4ACD 24,000 A FIXED 125/8 x 193/8 175/8 x 141/2 x 211/2 32 3
/4 5
/16
CCBA30A4ACD 30,000 A FIXED 125/8 x 193/8 175/8 x 141/2 x 211/2 32 3
/4 5
/16

PHASED OUT
CCBA36A4ACD 36,000 A FIXED 125/8 x 193/8 225/8 x 141/2 x 211/2 35 3
/4 5
/16
CCBB30A4ACD 30,000 A FIXED 155/8 x 193/8 175/8 x 171/2 x 211/2 41 3
/4 5
/16
CCBB36A4ACD 36,000 A FIXED 155/8 x 193/8 175/8 x 171/2 x 211/2 41 3
/4 5
/16
CCBB42A4ACD 42,000 A FIXED 155/8 x 193/8 225/8 x 171/2 x 211/2 49 3
/4 3
/8
11/2 – 5 Ton CCBB48A4ACD 48,000 A FIXED 155/8 x 193/8 225/8 x 171/2 x 211/2 54 3
/4 3
/8
Cased & Uncased CCBC48A4ACD 48,000 A FIXED 191/8 x 193/8 225/8 x 21 x 211/2 55 3
/4 3
/8
• Cased and uncased upflow CCBC60A4ACE 60,000 A FIXED 191/8 x 193/8 267/8 x 21 x 211/2 67 7
/8 3
/8
cooling only coils CCBD60A5ACD 60,000 A TXV-B 225/8 x 195/16 301/16 x 241/2 x 211/2 69 7
/8 3
/8
• Brazed fittings (left side)
• Drain fitting (left side) Table FUR-24-C — Brazed Uncased (Upflow Only)
• Fixed orifice flow control Nom. Cap. Uncrated Line Size
(except CCBD60A5ACD, Model Cooling Coil Refrigerant Dim. (in.) Shipping OD OD
Number (Btuh) Type Control Cased H x W x D Weight (Ibs.) Gas Liq.
CUBD60A5ACD-TXV-B)
• Shipped vertical upflow CUBA18A4ACD 18,000 A FIXED No 111/2 x 131/16 x 199/16 15 5
/8 5
/16
only CUBA24A4ACD 24,000 A FIXED No 145/8 x 131/16 x 199/16 18 3
/4 5
/16
• Painted coil case CUBA30A4ACD 30,000 A FIXED No 145/8 x 131/16 x 199/16 18 3
/4 5
/16
• Suction pressure service CUBA36A4ACD 36,000 A FIXED No 193/4 x 131/16 x 199/16 18 3
/4 5
/16
port CUBB24A4ACD 24,000 A FIXED No 153/16 x 161/16 x 199/16 23 3
/4 5
/16

PHASED OUT
• 100% foil lined insulation CUBB30A4ACD 30,000 A FIXED No 16 x 161/16 x 199/16 24 3
/4 5
/16
• Split inner and outer doors CUBB36A4ACD 36,000 A FIXED No 16 x 161/16 x 199/16 24 3
/4 5
/16
for easy coil cleaning CUBB42A4ACD 42,000 A FIXED No 191/8 x 161/16 x 199/16 24 3
/4 3
/8
• 5 year limited parts CUBB48A4ACD 48,000 A FIXED No 211/4 x 161/16 x 199/16 29 3
/4 3
/8
warranty CUBC36A4ACD 36,000 A FIXED No 165/16 x 199/16 x 199/16 27 3
/4 5
/16
CUBC42A4ACD 42,000 A FIXED No 189/16 x 199/16 x 199/16 34 3
/4 3
/8
CUBC48A4ACD 48,000 A FIXED No 2011/16 x 199/16 x 199/16 32 3
/4 3
/8
CUBC60A4ACD 60,000 A FIXED No 247/8 x 199/16 x 199/16 31 7
/8 3
/8
CUBD48A4ACD 48,000 A FIXED No 205/8 x 231/16 x 199/16 37 3
/4 3
/8
CUBD60A5ACD 60,000 A TXV-B No 277/16 x 231/16 x 199/16 44 3
/4 3
/8

For complete equipment / combination


Effective 1/1/06 FUR-24 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Split System – Uncased
Coil Enclosures

Table FUR-25-A — Coil Enclosures


Model Coils Cooling or Used With Furnaces Outlet Dimensions (in) Dimensions (in.) Shipping
Number Heat Pump Flush on Both Sides W/H x D H x W x D Weight (Ibs.)
1 5 5 1 1 1
BAYCLE1400C TXA018C4 14 /2" Wide Furnaces 12 /8 x 19 /16 22 /2 x 14 /2 x 21 /2 12
TXA024C4
TXA030C4
BAYCLE1700C TXA025C4 171/2" Wide Furnaces 155/8 x 195/16 221/2 x 171/2 x 211/2 14
TXA031C4
TXA035C4
TXA036C4
TXA042C4
TXA048C4
BAYCLE2100C TXA037C4 21" Wide Furnaces 191/8 x 195/16 30 x 21 x 211/2 18
TXA043C4
TXA049C4
TXA060C5
RXA060S3
BAYCLE2400C TXA061C5 241/2" Wide Furnaces 225/8 x 195/16 30 x 241/2 x 211/2 22
RXA061S3

Table FUR-25-B — 13 SEER Coil Enclosures


Model Used With Furnaces Dimensions (in.) Shipping
Number Coils Cooling or Heat Pump Flush on Both Sides H x W x D Weight (Ibs.)
BAYCLE14A1422A 2/4CXAA018AC3CUA TXA018C4 141/2" Wide Furnace 221/2 x 141/2 x 211/2 12
2/4CXAA024AC3CUA TXA024C4
TXA030C4
BAYCLE17A1722A 2/4CXAB025AC3CUA TXA025C4 171/2" Wide Furnace 225/8 x 171/2 x 211/2 14
2/4CXAB031AC3CUA TXA031C4
2/4CXAB036AC3CUA TXA035C4
2/4CXAB042AC3CUA TXA036C4
2/4CXAB048AC3CUA TXA042C4
TXA048C4
BAYCLE21A2130A 2/4CXAC037AC3CUA TXA037C4 21" Wide Furnace 30 x 21 x 211/2 18
2/4CXAC043AC3CUA TXA043C4
2/4CXAC049AC3CUA TXA049C4
2/4CXAC060AC3CUA TXA060C5
RXA060S3
BAYCLE24A2430A 2/4CXAD050AC3CUA TXA061C5 241/2" Wide Furnace 30 x 241/2 x 211/2 22
2/4CXAD061AC3CUA RXA061S3

Table FUR-25-C — ComfortTM Coil Door Kits


Model Number Case Height Used With
BAYCCKT1750A 17.5 TXC018,024,025,031-C-A,B
BAYCCKT2250A 22.5 TXC030,035,036,037,042,043-C-A,B
TXC031-E/S-A,B
BAYCCKT3000A 30.0 TXC048,049,050,060,061-C-A,B
TXC036,037,054,065-E/S-A,B

For complete equipment / combination


selections and installation instructions, please FUR-25 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XL 90, XV 90 & Coils


Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUX060R936W 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX060R936W 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUX080R942W 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX080R942W 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
2CXCB036A TXC036C 2CXAB036A TXA036C 2CXCB036A TXC036C 2CXAB036A TXA036C
2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C 2CXAB042A TXA042C
2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C 2CXAB048A TXA048C
2TXCB025A TXC025D 2TXCB025A TXC025D
2TXCB031A TXC031D 2TXCB031A TXC031D
2TXCB036A TXC036D 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUX100R948W 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100R948W 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C 2CXAC043A TXA043C
2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C
2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42 A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUX120R960W 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120R960W 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C 2CXAD061A TXA061C
2TXCD050A TXC065S1 2TXCD050A TXC065S1
2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
TUY060R9V3W 17.5" TXC031E TDY060R9V3W 17.5" TXC031E
TUY080R9V3W 17.5" TXC036E TDY080R9V3W 17.5" TXC036E
TXC031S TXC031S
TXC036S TXC036S
RXC025S RXC025S
RXC031S RXC031S
RXC036S RXC036S
TUY100R9V4W 21" TXC037E TDY100R9V4W 21" TXC037E
TXC054E TXC054E
TXC037S TXC037S
TXC054S TXC054S
RXC037S RXC037S
RXC054S RXC054S
TUY120R9V5W 24.5" TXC065S1 TDY120R9V5W 24.5" TXC065S1
RXC061S RXC061S
RXC065S1 RXC065S1
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


Effective 1/1/06 FUR-26 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XT 90 & Coils
Matching Matching Matching Matching
Furnace Cabinet Cased Uncased Furnace Cabinet Cased Uncased
Model Width Coils Coils Model Width Coils Coils
TUX1B040A9H21A 17.5" 2CXCB025A 2CXAB025A TDX1B040A9H31A 17.5" 2CXCB025A 2CXAB025A
TUX1B060A9H31A 17.5" 2CXCB031A 2CXAB031A TDX1B060A9H31A 17.5" 2CXCB031A 2CXAB031A
TUX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A TDX1B080A9H31A 17.5" 2CXCB036A 2CXAB036A
2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A
2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A
2TXCB025A 2TXCB025A
2TXCB031A 2TXCB031A
2TXCB036A 2TXCB036A
2TXCB042A 2TXCB042A
2TXCB048A 2TXCB048A
4CXCB025A 4CXCB025A
4CXCB031A 4CXCB031A
4CXCB036A 4CXCB036A
4CXCB042A 4CXCB042A
4CXCB048A 4CXCB048A
4TXCB025A 4TXCB025A
4TXCB031A 4TXCB031A
4TXCB036A 4TXCB036A
4TXCB042A 4TXCB042A
4TXCB048A 4TXCB048A
TUX1C100A9H41A 21" 2CXCC037A 2CXAC037A TDX1C100A9H41A 21" 2CXCC037A 2CXAC037A
2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A
2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A
2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A
2TXCC037A 2TXCC037A
2TXCC043A 2TXCC043A
2TXCC049A 2TXCC049A
2TXCC054A 2TXCC054A
2TXCC060A 2TXCC060A
4CXCC037A 4CXCC037A
4CXCC043A 4CXCC043A
4CXCC049A 4CXCC049A
4CXCC060A 4CXCC060A
4TXCC037A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDX1D120A9H51A 24.5" 2CXCD050A 2CXAD050A
2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A
2TXCD050A 2TXCD050A
2TXCD061A 2TXCD061A
2TXCD065A 2TXCD065A
4CXCD050A 4CXCD050A
4CXCD061A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications

For complete equipment / combination


selections and installation instructions, please FUR-27 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XR 90 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDX040C924D 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDX060C936D 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDX080C942D 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C TDX1B040A9241A 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C
TUX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C TDX1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C
TUX1B080A9421A 17.5" 2TXCB025A TXC025D TDX1B080A9421A 17.5" 2TXCB025A TXC025D
2TXCB031A TXC031D 2TXCB031A TXC031D
2TXCB036A TXC036D 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUX080C960D 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDX100C948D 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUX100C948D 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDX1C100A9481A 21" 2CXCC043A TXC043C 2CXAC043A TXA043C
TUX1C080A9601A 21" 2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C
TUX1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C 2CXAC060A TXA060C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
2TXCC037A RXC054S 2TXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42 A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUX100C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDX120C960D 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUX120C960D 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDX1D120A9601A 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C
TUX1D100A9601A 2TXCD050A TXC065S1 2TXCD050A TXC065S1
TUX1D120A9601A 2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A

NOTE: For reference only on Flush Fit Applications


1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


Effective 1/1/06 FUR-28 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XB 90 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUC040C924B 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDC040C924B 17.5" 2CXCB025A TXC025C TXA025C
TUC060C936B 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDC060C936B 17.5" 2CXCB031A TXC031C TXA031C
TUC080C942B 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDC080C942B 17.5" 2CXCB036A TXC036C TXA036C
2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C TXA042C
2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C TXA048C
2TXCB025A TXC025D 2TXCB025A TXC025D
2TXCB031A TXC031D 2TXCB031A TXC031D
2TXCB036A TXC036D 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUC100C948B 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDC100C948B 21" 2CXCC037A TXC037C TXA037C
2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C TXA043C
2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C TXA049C
2CXCC060A TXC060C 2CXAC060A TXA060C 2CXCC060A TXC060C TXA060C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42 A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUC100C960B 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDC120C960B 24.5" 2CXCD050A TXC050C TXA060C
TUC120C960B 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C TXA061C
2TXCD050A TXC065S1 2TXCD050A TXC065S1
2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


selections and installation instructions, please FUR-29 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XV 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils

TUD060R9V3K 17.5" TXC031E TDD060R9V3F 17.5" TXC031E


TUD080R9V3K 17.5" TXC036E TDD080R9V3F 17.5" TXC036E
TUD100R9V3K TXC031S TXC031S
TXC036S TXC036S
RXC025S RXC025S
RXC031S RXC031S
RXC036S RXC036S
TUD080R9V4K 21" TXC054E TDD100R9V5F 21" TXC037E
TUD100R9V5K 21" TXC037E TXC054E
TXC037S TXC037S
TXC054S TXC054S
RXC037S RXC037S
RXC054S RXC054S
TUD120R9V5K 24.5" TXC065S1 TDD120R9V5F 24.5" TXC065S1
TUD140R9V5K 24.5" RXC061S RXC061S
RXC065S1 RXC065S1
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


Effective 1/1/06 FUR-30 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XL 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUD040R924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040R924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C
TUD060R936K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060R936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C
2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C
2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C
4CXCA018A TXC024D 4CXCA018A TXC024D
4CXCA024A TXC030D 4CXCA024A TXC030D
4TXCA018A TXC035D 4TXCA018A TXC035D
4TXCA024A CCBA18A CUBA18A 4TXCA024A
CCBA24A CUBA24A
CCBA30A CUBA30A
CCBA36A CUBA36A
TUD060R937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060R937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUD080R936K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080R936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUD080R948K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD100R945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUD100R936K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C 2CXCB042A TXC042C 2CXAB042A TXA042C
2CXCB048A TXC048C 2CXAB048A TXA031C 2CXCB048A TXC048C 2CXAB048A TXA048C
2TXCB025A TXC025D TXA036C 2TXCB025A TXC025D
2TXCB031A TXC031D TXA042C 2TXCB031A TXC031D
2TXCB036A TXC036D TXA048C 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUD100R948K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100R948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUD100R960K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100R960F 21" 2CXCC043A TXC043C 2CXAC043A TXA043C
2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C
2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXAC060A TXA050C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUD120R960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120R960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUD140R960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140R960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C
2TXCD050A TXC065S1 2TXCD050A TXC065S1
2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


selections and installation instructions, please FUR-31 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XT 80 & Coils
Matching Matching Matching Matching
Furnace Cabinet Cased Height Uncased Height Furnace Cabinet Cased Height Uncased Height
Model Width Coils Inches Coils Inches Model Width Coils Inches Coils Inches
TUD1A040A9H21A 14.5" 2CXCA018A 2CXAA018A
2CXCA024A 2CXAA024A
2TXCA018A
2TXCA024A
2TXCA024A
4CXCA018A
4CXCA024A
4TXCA018A
4TXCA024A
TUD1B060A9H31A 17.5" 2CXCB025A 2CXAB025A TDD1B060A9H31A 17.5" 2CXCB025A 2CXAB025A
TUD1B080A9H31A 17.5" 2CXCB031A 2CXAB031A TDD1B080A9H31A 17.5" 2CXCB031A 2CXAB031A
TUD1B100A9H31A 17.5" 2CXCB036A 2CXAB036A 2CXCB036A 2CXAB036A
2CXCB042A 2CXAB042A 2CXCB042A 2CXAB042A
2CXCB048A 2CXAB048A 2CXCB048A 2CXAB048A
2TXCB025A 2TXCB025A
2TXCB031A 2TXCB031A
2TXCB036A 2TXCB036A
2TXCB042A 2TXCB042A
2TXCB048A 2TXCB048A
4CXCB025A 4CXCB025A
4CXCB031A 4CXCB031A
4CXCB036A 4CXCB036A
4CXCB042A 4CXCB042A
4CXCB048A 4CXCB048A
4TXCB025A 4TXCB025A
4TXCB031A 4TXCB031A
4TXCB036A 4TXCB036A
4TXCB042A 4TXCB042A
4TXCB048A 4TXCB048A
TUD1C080A9H41A 21" 2CXCC037A 2CXAC037A TDD1C100A 21" 2CXCC037A 2CXAC037A
TUD1C100A9H51A 21" 2CXCC043A 2CXAC043A 2CXCC043A 2CXAC043A
2CXCC049A 2CXAC049A 2CXCC049A 2CXAC049A
2CXCC060A 2CXAC060A 2CXCC060A 2CXAC060A
2TXCC037A 2TXCC037A
2TXCC043A 2TXCC043A
2TXCC049A 2TXCC049A
2TXCC054A 2TXCC054A
2TXCC060A 2TXCC060A
4CXCC037A 4CXCC037A
4CXCC043A 4CXCC043A
4CXCC049A 4CXCC049A
4CXCC060A 4CXCC060A
4TXCC037A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUD1D120A9H51A 24.5" 2CXCD050A 2CXAD050A TDD1D120A 24.5" 2CXCD050A 2CXAD050A
TUD1D140A9H51A 24.5" 2CXCD061A 2CXAD061A 2CXCD061A 2CXAD061A
2TXCD050A 2TXCD050A
2TXCD061A 2TXCD061A
2TXCD065A 2TXCD065A
4CXCD050A 4CXCD050A
4CXCD061A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications

For complete equipment / combination


Effective 1/1/06 FUR-32 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix

XR 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUD040C924K 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDD040C924F 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C
TUD040C930K 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C TDD060C936F 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C
TUD060C924K 14.5" 2TXCA018A TXC030C TXA030C TDD060C936F 14.5" 2TXCA018A TXC030C TXA030C
TUD060C936K 14.5" 2TXCA024A TXC035C TXA035C TDD1A040A9241A 14.5" 2TXCA024A TXC035C TXA035C
TUD1A040A9241A 14.5" 4CXCA018A TXC024D TDD1A060A9241A 14.5" 4CXCA018A TXC024D
TUD1A040A9301A 14.5" 4CXCA024A TXC030D TDD1A060A9361A 14.5" 4CXCA024A TXC030D
TUD1A060A9301A 14.5" 4TXCA018A TXC035D 4TXCA018A TXC035D
TUD1A060A9241A 14.5" 4TXCA024A CCBA18A CUBA18A 4TXCA024A
CCBA24A CUBA24A
CCBA30A CUBA30A
CCBA36A CUBA36A
TUD060C937K 17.5" 2CXCB025A TXC025C 2CXAB025A TDD060C937F 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUD080C924K 17.5" 2CXCB031A TXC031C 2CXAB031A TDD080C936F 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUD080C936K 17.5" 2CXCB036A TXC036C 2CXAB036A TDD080C945F 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUD080C948K 17.5" 2CXCB042A TXC042C 2CXAB042A TXA025C TDD100C945F 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C
TUD100C936K 17.5" 2CXCB048A TXC048C 2CXAB048A TXA031C TDD1B060A9361A 17.5" 2CXCB048A TXC048C 2CXAB048A TXA048C
TUD100C945K 17.5" 2TXCB025A TXC025D TXA036C TDD1B080A9361A 17.5" 2TXCB025A TXC025D
TUD1B060A9361A 17.5" 2TXCB031A TXC031D TXA042C TDD1B080A9451A 17.5" 2TXCB031A TXC031D
TUD1B080A9241A 17.5" 2TXCB036A TXC036D TXA048C TDD1B100A9451A 17.5" 2TXCB036A TXC036D
TUD1B080A9361A 17.5" 2TXCB042A TXC031E 2TXCB042A TXC031E
TUD1B080A9481A 17.5" 2TXCB048A TXC036E 2TXCB048A TXC036E
TUD1B100A9361A 17.5" 4CXCB025A TXC031S 4CXCB025A TXC031S
TUD1B100A9451A 17.5" 4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUD080C960K 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDD100C948F 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUD100C948K 21" 2CXCC043A TXC043C 2CXAC043A TXA043C TDD100C954F 21" 2CXCC043A TXC043C 2CXAC043A TXA043C
TUD100C960K 21" 2CXCC049A TXC049C 2CXAC049A TXA049C TDD120C954F 21" 2CXCC049A TXC049C 2CXAC049A TXA049C
TUD120C954K 21" 2CXCC060A TXC060C 2CXAC060A TXA050C TDD1C100A9481A 21" 2CXCC060A TXC060C 2CXAC060A TXA050C
TUD1C080A9601A 2TXCC037A TXC037E TDD1C100A9541A 21" 2TXCC037A TXC037E
TUD1C100A9481A 2TXCC043A TXC054E TDD1C120A9541A 21" 2TXCC043A TXC054E
TUD1C100A9601A 2TXCC049A TXC037S 2TXCC049A TXC037S
TUD1C120A9541A 2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUD120C960K 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDD120C960F 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUD140C960K 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C TDD140C960F 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C
TUD1D100A9721A 2TXCD050A TXC065S1 TDD1D120A9601A 24.5" 2TXCD050A TXC065S1
TUD1D120A9601A 2TXCD061A RXC061S TDD1D140A9601A 24.5" 2TXCD061A RXC061S
TUD1D140A9601A 2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


selections and installation instructions, please FUR-33 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Furnace/Coils
Matrix
XB 80 & Coils
Furnace Cabinet Matching Matching Furnace Cabinet Matching Matching
Model Width Cased Coils Uncased Coils Model Width Cased Coils Uncased Coils
TUE040A924L 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C TDE060A936M 14.5" 2CXCA018A TXC018C 2CXAA018A TXA018C
TUE060A936L 14.5" 2CXCA024A TXC024C 2CXAA024A TXA024C 2CXCA024A TXC024C 2CXAA024A TXA024C
2TXCA018A TXC030C TXA030C 2TXCA018A TXC030C TXA030C
2TXCA024A TXC035C TXA035C 2TXCA024A TXC035C TXA035C
4CXCA018A TXC024D 4CXCA018A TXC024D
4CXCA024A TXC030D 4CXCA024A TXC030D
4TXCA018A TXC035D 4TXCA018A TXC035D
4TXCA024A CCBA18A CUBA18A 4TXCA024A
CCBA24A CUBA24A
CCBA30A CUBA30A
CCBA36A CUBA36A
TUE060A937L 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C TDE060A937M 17.5" 2CXCB025A TXC025C 2CXAB025A TXA025C
TUE080A936L 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C TDE080A945M 17.5" 2CXCB031A TXC031C 2CXAB031A TXA031C
TUE080A948L 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C TDE100A945M 17.5" 2CXCB036A TXC036C 2CXAB036A TXA036C
TUE100A936L 17.5" 2CXCB042A TXC042C 2CXAB042A TXA042C 2CXCB042A TXC042C 2CXAB042A TXA042C
2CXCB048A TXC048C 2CXAB048A TXA048C 2CXCB048A TXC048C 2CXAB048A TXA048C
2TXCB025A TXC025D 2TXCB025A TXC025D
2TXCB031A TXC031D 2TXCB031A TXC031D
2TXCB036A TXC036D 2TXCB036A TXC036D
2TXCB042A TXC031E 2TXCB042A TXC031E
2TXCB048A TXC036E 2TXCB048A TXC036E
4CXCB025A TXC031S 4CXCB025A TXC031S
4CXCB031A TXC036S 4CXCB031A TXC036S
4CXCB036A RXC025S 4CXCB036A RXC025S
4CXCB042A RXC031S 4CXCB042A RXC031S
4CXCB048A RXC036S 4CXCB048A RXC036S
4TXCB025A CUBB24A 4TXCB025A
4TXCB031A CCBB30A CUBB30A 4TXCB031A
4TXCB036A CCBB36A CUBB36A 4TXCB036A
4TXCB042A CCBA42A CUBB42A 4TXCB042A
4TXCB048A CCBA48A CUBB48A 4TXCB048A
TUE100A948L 21" 2CXCC037A TXC037C 2CXAC037A TXA037C TDE100A960M 21" 2CXCC037A TXC037C 2CXAC037A TXA037C
TUE100A960L 21" 2CXCC043A TXC043C 2CXAC043A TXA043C 2CXCC043A TXC043C 2CXAC043A TXA043C
2CXCC049A TXC049C 2CXAC049A TXA049C 2CXCC049A TXC049C 2CXAC049A TXA049C
2CXCC060A TXC060C 2CXAC060A TXA050C 2CXCC060A TXC060C 2CXCC060A TXC050C
2TXCC037A TXC037E 2TXCC037A TXC037E
2TXCC043A TXC054E 2TXCC043A TXC054E
2TXCC049A TXC037S 2TXCC049A TXC037S
2TXCC054A TXC054S 2TXCC054A TXC054S
2TXCC060A RXC037S 2TXCC060A RXC037S
4CXCC037A RXC054S 4CXCC037A RXC054S
4CXCC043A CUBC36A 4CXCC043A
4CXCC049A CUBC42A 4CXCC049A
4CXCC060A CCBC48A CUBC48A 4CXCC060A
4TXCC037A CCBC60A CUBC60A 4TXCC037A
4TXCC043A 4TXCC043A
4TXCC049A 4TXCC049A
4TXCC054A 4TXCC054A
4TXCC060A 4TXCC060A
TUE120A960L 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C TDE120A960M 24.5" 2CXCD050A TXC050C 2CXAD050A TXA060C
TUE140A960L 24.5" 2CXCD061A TXC061C 2CXAD061A TXA061C 2CXCD061A TXC061C 2CXAD061A TXA061C
2TXCD050A TXC065S1 2TXCD050A TXC065S1
2TXCD061A RXC061S 2TXCD061A RXC061S
2TXCD065A RXC065S1 2TXCD065A RXC065S1
4CXCD050A CUBD48A 4CXCD050A
4CXCD061A CCBD60A CUBD60A 4CXCD061A
4TXCD050A 4TXCD050A
4TXCD061A 4TXCD061A
4TXCD065A 4TXCD065A
NOTE: For reference only on Flush Fit Applications
1 Coil apex extends above case, actual height of case is 30" (Downflow application of coil is not recommended).

For complete equipment / combination


Effective 1/1/06 FUR-34 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
TRANE “CleanEffects™”
Air Cleaner and Upgrade Kits

Table IDAQ-1-A – Air Handler – 24 Volt TRANE CleanEffects™ Whole House Air
Cleaner
TRANE Uncrated
Model Airflow CleanEffects™ Dimensions(in.) Shipping
Number Range Air Handler Width H xW x D Weight
TFD215ALAH000A 300-1200 211/2 inch 71/2 x 211/2 x 21 42
TFD235ALAH000A 350-1600 231/2 inch 71/2 x 231/2 x 21 44
TFD260ALAH000A 400-2000 26 inch 71/2 x 26 x 21 46

Table IDAQ-1-B – Upflow / Side Return Furnace – 24 Volt TRANE CleanEffects™


TRANE Uncrated
Model Airflow CleanEffects™ Dimensions(in.) Shipping
Number Range Air Handler Width H xW x D Weight
TRANE CleanEffects™ TFD145ALFR000A 300-1200 141/2 inch1 71/2 x 141/2 x 27 39
Air Cleaner: TFD175ALFR000A 300-1600 171/2 inch1 71/2 x 171/2 x 27 43
TFD210ALFR000A 300-2000 21 inch2 71/2 x 21 x 27 47
• TRANE CleanEffects™ removes up to
TFD245ALFR000A 400-2000 241/2 inch2 71/2 x 241/2 x 27 49
99.98% of allergens from the filtered air
• Removes particles down to .3 microns in
Table IDAQ-1-C – Downflow Furnace – 24 Volt TRANE CleanEffects™
size
TRANE Uncrated
• Outperforms HEPA, and up to 100 times Model Airflow CleanEffects™ Dimensions(in.) Shipping
more effective than a standard 1" filter Number Range Air Handler Width H xW x D Weight
• Constructed of heavy 18 gage metal to TFD14DALFR000A 300-1200 141/2 inch 71/2 x 141/2 x 21 33
protect the filter and internal electronics TFD17DALFR000A 300-1600 171/2 inch 71/2 x 171/2 x 21 37
• Power door provides easy access to TFD21DALFR000A 300-2000 21 inch 71/2 x 21 x 21 41
internal components and features a filter TFD24DALFR000A 400-2000 241/2 inch 71/2 x 241/2 x 21 45
status display as well as safety interlocks
that automatically shut down the power Table IDAQ-1-D– Air Handler – TRANE CleanEffects™ Upgrade Kit
when the door is opened for maintenance or Model Airflow Perfect Fit™ Shipping
cleaning Number Range Cabinet Width Weight
• Designed for flush fit on both sides and rear TFD215ALUPGRDA 300-1200 211/2 inch 38
of equipment cabinet TFD235ALUPGRDA 350-1600 231/2 inch 40
• No transitions required on TRANE TFD260ALUPGRDA 400-2000 26 inch 42
CleanEffects™ applications
• Gaskets included with the air cleaner Table IDAQ-1-E – Furnace – TRANE CleanEffects™ Upgrade Kit
• 24 Volt input power Model Airflow Perfect Fit™ Shipping
• 10 year electronics warranty Number Range Cabinet Width Weight
• 5 year parts warranty TFD145ALUPGRD 300-1200 141/2 inch1 35
TFD175ALUPGRD 300-1600 171/2 inch1 39
TFD210ALUPGRD 300-2000 21 inch2 43
TFD245ALUPGRD 400-2000 241/2 inch2 45
TRANE CleanEffects™ Table IDAQ-1-F – Downflow Furnace – TRANE CleanEffects™ Upgrade Kit
Upgrade Kits: Model Airflow Perfect Fit™ Shipping
• Fits any “Perfect Fit™” Air Cleaner Number Range Cabinet Width Weight
cabinet. TFD14DALUPGRD 300-1200 141/2 inch 29
• Easily convert Perfect Fit™, TFP, TFM or TFD17DALUPGRD 300-1600 171/2 inch 33
TFE product to TRANE CleanEffects™ Air TFD21DALUPGRD 300-2000 21 inch 37
Cleaner TFD24DALUPGRD 400-2000 241/2 inch 41
• 24 Volt input power
• 10 year electronics warranty. Table IDAQ-1-G — Accessories – TRANE CleanEffects™ and Upgrade Kits
• 5 year parts warranty. Model Shipping
Number Description Used With Weight
BAYTRANS12024 120 to 24 Volt Transformer All TFD Air Cleaners 6
1 Side return no Transition Required.
2 Side return Transition Required.

For complete equipment / combination


selections and installation instructions, please IDAQ-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
“Perfect Fit™” Air Cleaner

• Three sizes to flush fit TWE/4TEE/4TEP 6-way • “Air-Tite™” Door construction eliminates
convertible Air Handler return. air leaks, improves air quality and keeps
• Four sizes to flush fit bottom of Trane furnaces. operating costs low.
• TFP175, TFM175, TFE175 (171/2") bottom • Gaskets included with the air cleaner.
return model can be used for a “Perfect Fit™” • Built-In Air Sensor Switch senses when air
side return on all furnace models. flows through the power assembly on and
• Air Cleaners designed for flush fit on both sides off automatically;
and rear of equipment cabinet. No “Power On” relay required.
• All service and access is from the front of the air • Air Cleaner furnace models come with a
cleaner. 120 volt power supply.
• Cabinet case versatility provides three levels of • Air Cleaner Air Handler models come with a
air quality. 240 volt power supply or 120 volt power
• All Electronic Air Cleaners are shipped with a 1" supply.
washable metal pre-filter.

Table IDAQ-2-A – Air Handler “Perfect Fit™” Dual Filtration Electronic Air Cleaner System With One (1) Inch Pre-Filter
(120 Volt or 240 volt)
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Voltage Air Handler Width H xW x D Weight 3
Air Opening3
TFE215A9AH3 300-1400 120 211/2 inch 71/2 x 211/2 x 21 45 187/8 x187/8
TFE235A9AH3 300-1800 120 231/2 inch 71/2 x 231/2 x 21 49 207/8 x187/8
TFE260A9AH3 400-2100 120 26 inch 71/2 x 26 x 21 53 237/8 x187/8
TFE215A1AH3 300-1400 240 211/2 inch 71/2 x 211/2 x 21 45 187/8 x187/8
TFE235A1AH3 300-1800 240 231/2 inch 71/2 x 231/2 x 21 49 207/8 x187/8
TFE260A1AH3 400-2100 240 26 inch 71/2 x 26 x 21 53 237/8 x187/8

Table IDAQ-2-B – Furnace “Perfect Fit™” Dual Filtration Electronic Air Cleaner System With One (1) Inch Pre-Filter (120 Volt)
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Voltage Air Handler Width H xW x D Weight 3
Air Opening3
TFE145A9FR3 300-1200 120 141/2 inch1 71/2 x141/2 x 27 44 117/8 x2413/16
TFE175A9FR3 300-1500 120 171/2 inch1 71/2 x 171/2 x 27 48 147/8 x2413/16
TFE210A9FR3 300-2000 120 21 inch2 71/2 x 21 x 27 54 183/8 x2413/16
TFE245A9FR3 400-2200 120 241/2 inch2 71/2 x 241/2 x 27 60 217/8 x2413/16

Table IDAQ-2-C — Accessories: 1" Permanent - Washable Filter (Ordered through Parts)
Replacement Previous Enclosure
Part Number Model Number Description Used With
FLR03831 BAYFTFR14W1A 1" PERMANENT - Washable 14-1/2
FLR03832 BAYFTFR17W1A 1" PERMANENT - Washable 17-1/2
FLR03833 BAYFTFR21W1A 1" PERMANENT - Washable 21
FLR03834 BAYFTFR24W1A 1" PERMANENT - Washable 24-1/2

FLR03835 BAYFTAH21W1A 1" PERMANENT - Washable 21-1/2


FLR03836 BAYFTAH23W1A 1" PERMANENT - Washable 23-1/2
FLR03837 BAYFTAH26W1A 1" PERMANENT - Washable 26
1 Side return no Transition Required.
2 Side return Transition Required.
3 Actual opening does not include flange.

For complete equipment / combination


Effective 1/1/06 IDAQ-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
“Perfect Fit™” Air Cleaner

• Three sizes to flush fit TWE/4TEE/4TEP 6-way • “Air-Tite™” Door construction eliminates
convertible Air Handler return. air leaks, improves air quality and keeps
• Four sizes to flush fit bottom of Trane furnaces. operating costs low.
• Air Cleaners designed for flush fit on both sides • Gaskets included with the air cleaner.
and rear of equipment cabinet.
• All service and access is from the front of the air
cleaner.

Table IDAQ-3-A– Air Handler “Perfect Fit™” High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFM215B0AH0 300-1400 211/2 inch 71/2 x 211/2 x 21 22 187/8 x187/8
TFM235B0AH0 300-1700 231/2 inch 71/2 x 231/2 x 21 24 207/8 x187/8
TFM260B0AH0 400-2100 26 inch 71/2 x 26 x 21 25 237/8 x187/8

Table IDAQ-3-B – Furnace “Perfect Fit™”High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFM145B0FR0 300-1200 141/2 inch1 71/2 x141/2 x 27 18 117/8 x2413/16
TFM175B0FR0 300-1500 171/2 inch1 71/2 x 171/2 x 27 21 147/8 x2413/16
TFM210B0FR0 300-2000 21 inch2 71/2 x 21 x 27 24 183/8 x2413/16
TFM245B0FR0 400-2000 241/2 inch2 71/2 x 241/2 x 27 27 217/8 x2413/16

Table IDAQ-3-C – Downflow Furnace “Perfect Fit™”High Efficiency Air Cleaner With Five (5) Inch Expandable Media Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFM14DA0FR0 300-1200 141/2 inch 71/2 x141/2 x 21 17 117/8 x187/8
TFM17DA0FR0 300-1500 171/2 inch 71/2 x 171/2 x 21 19 147/8 x187/8
TFM21DA0FR0 300-2000 21 inch 71/2 x 21 x 21 22 183/8x187/8
TFM24DA0FR0 400-2000 241/2 inch 71/2 x 241/2 x 21 24 217/8 x187/8

Table IDAQ-3-D – Air Handler “Perfect Fit™” Medium Efficiency Air Cleaner With One (1) Inch Pleated Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFP215A0AH1 300-1200 211/2 inch 71/2 x 211/2 x 21 20 187/8 x187/8
TFP235A0AH1 300-1500 231/2 inch 71/2 x 231/2 x 21 22 207/8 x187/8
TFP260A0AH1 400-1800 26 inch 71/2 x 26 x 21 24 237/8 x187/8

Table IDAQ-3-E – Furnace “Perfect Fit™” Medium Efficiency Air Cleaner With One (1) Inch Pleated Filter
Uncrated
Model Airflow Perfect Fit™ Dimensions(in.) Shipping Return
Number Range Air Handler Width H xW x D Weight 3
Air Opening3
TFP145A0FR1 300-1200 141/2 inch1 71/2 x141/2 x 27 17 117/8 x2413/16
TFP175A0FR1 300-1500 171/2 inch1 71/2 x 171/2 x 27 19 147/8 x2413/16
TFP210A0FR1 400-1800 21 inch2 71/2 x 21 x 27 22 183/8 x2413/16
TFP245A0FR1 400-2000 241/2 inch2 71/2 x 241/2 x 27 25 217/8 x2413/16
1 Side return no Transition Required.
2 Side return Transition Required.
3 Actual opening does not include flange.

For complete equipment / combination


selections and installation instructions, please IDAQ-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
“Perfect Fit™” Filter Accessories

Table IDAQ-4-A — Furnace Enclosure Filters


Model Enclosure Shipping
Number Description Qty Used with Weight
BAYFTFR14P4 1" Pleated Filter 4 / Box 14 1/2 3
BAYFTFR17P4 1" Pleated Filter 4 / Box 17 1/2 3
BAYFTFR21P4 1" Pleated Filter 4 / Box 21 3
BAYFTFR24P4 1" Pleated Filter 4 / Box 24 1/2 3
BAYFTFR14M2 5" Media Filter 2 / Box 14 1/2 5
BAYFTFR17M2 5" Media Filter 2 / Box 17 1/2 5
BAYFTFR21M2 5" Media Filter 2 / Box 21 5
BAYFTFR24M2 5" Media Filter 2 / Box 24 1/2 6
BAYFTFREXM2 Expandable 5" Cartridge Media Filter 2 / Box 14 1/2-24 1/2 5

Table IDAQ-4-B — Air Handler Enclosure Filters


Model Enclosure Shipping
Number Description Qty Used with Weight
BAYFTAH21P4 1" Pleated Filter 4 / Box 21 1/2 3
BAYFTAH23P4 1" Pleated Filter 4 / Box 23 1/2 3
BAYFTAH26P4 1" Pleated Filter 4 / Box 26 3
BAYFTAH21M2 5" Media Filter 2 / Box 21 1/2 5
BAYFTAH23M2 5" Media Filter 2 / Box 23 1/2 5
BAYFTAH26M2 5" Media Filter 2 / Box 26 6
BAYFTAHEXM2 Expandable 5" Cartridge Media Filter 2 / Box 21 1/2-26 5

Table IDAQ-4-C — Downflow Cartridge Media


Model Enclosure Shipping
Number Description Qty Used with Weight
BAYFTDN14M2 5" Downflow Media Filter 2/ Box 14 D 5
BAYFTDN17M2 5" Downflow Media Filter 2/ Box 17 D 5
BAYFTDN21M2 5" Downflow Media Filter 2/ Box 21 D 5
BAYFTDN24M2 5" Downflow Media Filter 2/ Box 24 D 5

Table IDAQ-4-D — Furnace Frames


Model Enclosure Shipping
Number Description Qty Used with Weight
BAYFRAME1451 Expandable Media Filter 1/ Box 14 1/2 5
BAYFRAME1751 Expandable Media Filter 1/ Box 17 1/2 5
BAYFRAME2101 Expandable Media Filter 1/ Box 21 5
BAYFRAME2451 Expandable Media Filter 1/ Box 24 1/2 5

Table IDAQ-4-E — Air Handler Frames


Model Enclosure Shipping
Number Description Qty Used with Weight
BAYFRAME2151 Expandable Media Frame 1/ Box 21 5
BAYFRAME2351 Expandable Media Frame 1/ Box 23 1/2 5
BAYFRAME2601 Expandable Media Frame 1/ Box 26 5
1 Includes one filter.

For complete equipment / combination


Effective 1/1/06 IDAQ-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
“Perfect Fit™”

Table IDAQ-5-A — Air Handler Filters


AIR HANDLER MODEL NUMBER
1" Pleated Filter 5" Media Filter Electronic Filter CleanEffects™ A B
TFP215A0AH0 TFM215A0AH0 TFE215A1AH0, A9AH0 TFD215ALAH000A 21-1/2 18-7/8
TFP235A0AH0 TFM235A0AH0 TFE235A1AH0, A9AH0 TFD235ALAH000A 23-1/2 20-7/8
TFP260A0AH0 TFM260A0AH0 TFE260A1AH0, A9AH0 TFD260ALAH000A 26 23-7/8

Side View

Top
of
Cabinet

For complete equipment / combination


selections and installation instructions, please IDAQ-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
“Perfect Fit™”

Table IDAQ-6-A — Upflow Furnace Filters


FURNACE MODEL NUMBER
1" Pleated Filter 5" Media Filter Electronic Filter CleanEffects™ A B
TFP145A0FR0 TFM145A0FR0 TFE145A9FR0 TFD145ALFR000A 14-1/2 11-7/8
TFP175A0FR0 TFM175A0FR0 TFE175A9FR0 TFD175ALFR000A 17-1/2 14-7/8
TFP210A0FR0 TFM210A0FR0 TFE210A9FR0 TFD210ALFR000A 21 18-3/8
TFP245A0FR0 TFM245A0FR0 TFE245A9FR0 TFD245ALFR000A 24-1/2 21-7/8

Table IDAQ-6-B — Downflow Furnace Filters


FURNACE MODEL NUMBER
5" Media Filter ifD Filter A B
TFM14DA0FR0 TFD14DALFR000A 14-1/2 11-7/8
TFM17DA0FR0 TFD17DALFR000A 17-1/2 14-7/8
TFM21DA0FR0 TFD21DALFR000A 21 18-3/8
TFM24DA0FR0 TFD24DALFR000A 24-1/2 21-7/8

OUTLINE DRAWING OUTLINE DRAWING UPFLOW FURNACE MODELS


DOWNFLOW FURNACE MODELS

Side View
Side View

Top
of
Cabinet
Top
of
Cabinet

For complete equipment / combination


Effective 1/1/06 IDAQ-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Humidifiers
Fan Powered and Bypass

THUMD500A
• Flow Through Fan Powered Humidifier • Reliable Brass Solenoid Valve w/Stainless
• High Performance Humidifier Delivers up to Steel Valve Seat
18 Gallons per Day • UV Resistant Cabinet and Scale Control
• Automatic Humidifier Control with O.D. Insert
Sensor for up to 50% more Humidity • Saddle Valve
• Front Cover Access for easy replacement of • Polyslate Gray Housing matches Furnace
humidifier pad. Cabinet Color
• Aluminum Humidifier Pad Treated with • Decorative nameplate
Ceramic Clay for Enhanced Pad Perfor- • 120V Power Line Cord
mance
THUMD500A

THUMD200,300A
• Reliable Brass Solenoid Valve w/Stainless
• THUMD300A Bypass delivers up to 17 Steel Valve Seat
Gallons per day • Field Convertible Duct Connection, Left or
• THUMD200A delivers up to 12 Gallons per Right Side
day. • Built in Summer / Winter Damper
• THUMD300A Automatic Humidifier Control • UV Resistant Cabinet and Scale Control
and O.D. Sensor for up to 50% more Insert
Humidity • Saddle Valve
• THUMD200A Manual Humidifier Control • Polyslate Gray Housing matches Furnace
• UV Resistant Cabinet and Scale Control Cabinet Color
Insert • Decorative nameplate
• Front Cover Access for easy replacement of • 120 V Primary
humidifier pad. • 24V Secondary, 10VA
THUMD200A, 300A • Aluminum Humidifier Pad Treated with
Ceramic Clay for Enhanced Pad Perfor-
mance

Table IDAQ-7-A — Specifications: Humidifier with Humidistat


Model Mfg. Shipping
Number Description Used With Plant Weight
THUMD500APA00A14 Fan Powered Humidifer All Furnace Models TY 1
THUMD300ABA00A2 Large Bypass Humidifier All Furnace Models TY 1
THUMD200ABM00A3 Small Bypass Humidifier All Furnace Models TY 1
1 Includes Automatic Humidifier Control (Duct Mount Only)
2 Includes Automatic Humidifier Control (Duct Mount Only) and 120/24V transformer
3 Includes Manual Humidifier Control and 120/24V transformer
4 Not applicable for horizontal installations

Table IDAQ-7-B — Accessories


Model Mfg. Shipping
Number Description Used With Plant Weight
BAYPAD02A1310A Large Humidifier Pad 13”x10” THUMD500,300A TY 1
BAYPAD01A1010A Small Humidifier Pad 9-7/8”x9-5/8” THUMD200A TY 1
TCONTH01AAUTOA Automatic Humidifier Control THUMD200A TY 1
BAYRLY10ASENSA Current Sensing Relay All TY 1
BAYPLT01AMHCOA Adapter Plate (Duct Mount) Manual Humidifier Control TY 1

For complete equipment / combination


selections and installation instructions, please IDAQ-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Humidifiers
Fan Powered and Bypass

THUMD500PA00A FAN POWERED HUMIDIFIER

THUMD300AB00A LARGE BYPASS HUMIDIFIER

THUMD200AB00A SMALL BYPASS HUMIDIFIER

For complete equipment / combination


Effective 1/1/06 IDAQ-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Humidifiers
Fan Powered and Bypass

MANUAL HUMIDIFIER CONTROL TCONTH01AAUTOA AUTOMATIC HUMIDIFIER CONTROL


(SHIP WITH THUMD200AB00A)

SUGGESTED BYPASS HUMIDFIER LOCATIONS

RETURN AIR

OPTIONAL FLUE
NOT ALL MODELS

SUPPLY AIR

For complete equipment / combination


selections and installation instructions, please IDAQ-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
FreshEffects™ Energy Recovery
Ventilator (ERV)

• FreshEffects™ ERV technology for all • 6” and 8” double collar duct connections for
seasons and climates TERVR100 and 200
• Static plate energy transfer core for efficient • 8” round compatible duct connection for
transfer of heat and moisture TERVR300
• Passive defrost - condensate drain not • Closed cell foam gasketing for insulation
required integrity
• Balancing dampers not required • 1” duct board insulation with
• Multi position mounting cleanable foil face
• Percent Timer (PT) control included with • May be installed in conditioned and
ERV for simple, automatic operation unconditioned spaces
• Optional push button control for use with PT • Cabinet / Door color: Trane Polyslate Gray /
control Tarpaulin Gray
• Cam action door latches for quick service • 5 year limited warranty on parts
access • 10 year limited warranty on energy
• Heavy gauge, powder painted steel cabinet transfer core
• Permanently lubricated motor bearings • Optional extended warranty

Table IDAQ-10-A — Specifications: ERV


Nominal Uncrated
Model Airflow Power Dimensions (In.) Shipping
Number (CFM) Supply H W D Weight
TERVR100A9P00A1 130 120/1/60 20-1/8 28-3/4 13 58
TERVR200A9P00A1 200 120/1/60 20-1/8 28-3/4 23-7/8 80
TERVR300A9P00A12 300 120/1/60 20-1/8 28-3/4 23-7/8 88
1 Percent Timer Control included with the ERV
2 Available in April 2006

Table IDAQ-10-B — Specifications: ERV


Model Apparent Sensible Sensible Recovery Latent Total
Number Effectiveness(32°F) Effectiveness(32°F) Recovery (32°F) Recovery (32°F)
TERVR100A9P00A 80% @ 120 cfm 84% @ 120 cfm 73% @ 251 cfm 51% @ 63 cfm
TERVR200A9P00A 72% @ 120 cfm 77% @ 120 cfm 64% @ 251 cfm 59% @ 63 cfm
TERVR300A9P00A2 44% @ 120 cfm 63% @ 120 cfm 40% @ 251 cfm 31% @ 252 cfm
2 Available in April 2006

Table IDAQ-10-C — Optional Accessories


Model Shipping
Number Description Used With Weight
TCONTV10APBC0A Point of Use Push Button Control ERV models 100, 200, 300 1
BAYFLT10A1010A Filters - 2 per pack ERV models 100 1
BAYFLT20A1020A Filters - 2 per pack ERV models 200, 300 1
BAYWHT10AVENTA3 6 inch White Vinyl Ventilation Hood ERV models 100, 200 1
BAYBRN10AVENTA3 6 inch Brown Vinyl Ventilation Hood ERV models 100, 200 1
BAYGLV10AVENTA3 8 inch Galvenized Ventilation Hood ERV models 300 2
3 Qty 1

For complete equipment / combination


Effective 1/1/06 IDAQ-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

• Ultra quiet operation provides best-in-class • Ships in horizontal configuration and converts
performance with barely noticeable sound quickly for downflow.
levels. • Complete set of customized electric heaters
• Appliance grade finish of durable powder designed for all models. Features a polarized
paint baked on both sides of the panels. plug for easy installation.
• Exclusive Climatuff® high efficiency • Optional filter rack kits fit inside the unit.
compressor with internal overload protection. Available for 1" or 2" media.
• Aerospace ducted outdoor fan with a high • Non-bleed expansion valves on indoor and
efficiency motor for quiet and reliable outdoor coils.
operation. • Direct drive 2 and 3 speed indoor blower
• Composite Vortica® blower provides better motors.
airflow and less sound while using less • Pressure taps easily accessed and protected
energy. inside compressor compartment.
• Spine Fin™ outdoor coil for long lasting • Easy access liquid line tap inside compressor
performance and durability. compartment.
• Right side electrical service for high and low • Standard operation to 55°F as manufactured.
voltage lines. • Low ambient cooling to 0°F with kit.
• Architecturally integrated louvers and corner
• Rugged steel basepan features deep drawn • UL approved and listed.
guards deliver durable protection, extra
duct connections and emergency drains. • 20 year heat exchanger, 10 year compres-
safety, and great looks.
• Steeply sloped composite drainpan will sor, 10 year outdoor coil, and 5 years other
• Weather Beater Top contoured for great
empty fast and never rust. parts limited warranty.
appearance and reinforced for strength.
(Residential Use Only)
• Optional extended warranty.
Table PC-1-A — 4TCX- XL13c - Convertible Package Cooling - R-410A
Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER Weight MCA Fuse Rating H xW x L
4TCX – 208/230/1/60
4TCX3018A1000A 18,800 13.65/11.20 444 10.1 15 69 36 x 51 x 43
4TCX3024A1000A 24,800 13.30/11.00 444 13.6 20 72 36 x 51 x 43
4TCX3030A1000A 29,800 13.15/11.65 445 21.7 35 72 36 x 51 x 43
4TCX3036A1000A 36,200 13.30/11.00 450 23.2 35 72 36 x 51 x 43
4TCX3042A1000A 43,500 13.05/11.00 523 27.9 45 72 38 x 46 x 61
4TCX3048A1000A 46,500 13.15/11.00 607 31.1 50 72 38 x 46 x 61
4TCX3060A1000A 60,500 13.40/11.05 610 43.3 60 72 40 x 46 x 61
4TCX – 208/230/3/60
4TCX3036A3000A 36,200 13.30/11.00 450 18.2 30 72 36 x 51 x 43
4TCX3048A3000A 46,500 13.14/11.00 607 23.6 35 72 38 x 46 x 61
4TCX3060A3000A 60,500 13.40/11.05 610 31.5 50 72 40 x 46 x 61
4TCX – 460/3/60
4TCX3036A4000A 36,200 13.30/11.00 450 8.7 15 72 36 x 51 x 43
4TCX3048A4000A 46,500 13.15/11.00 607 11.7 15 72 38 x 46 x 61
4TCX3060A4000A 60,500 13.40/11.00 610 19.3 25 79 40 x 46 x 61

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCX3018A through 4TCX3036A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PC-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCX3018A through 4TCX3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PC-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCX3042A through 4TCX3060A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PC-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCX3042A through 4TCX3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

• Quiet operation delivers great in-home • Complete set of customized electric heaters
comfort with minimal sound. designed for all models. Features a polarized
• Appliance grade finish of durable powder plug for easy installation.
paint baked on both sides of the panels. • Optional filter rack kits fit inside the unit.
• Exclusive Climatuff® high efficiency Available for 1" or 2" media.
compressor with internal overload protec- • Non-bleed expansion valves on indoor and
tion. outdoor coils.
• High efficiency outdoor fan motor for quiet • Direct drive 2 and 3 speed indoor blower
and reliable operation. motors.
• Composite Vortica® blower provides better • Pressure taps easily accessed and protected
airflow and less sound while using less inside compressor compartment.
energy. • Easy access liquid line tap inside compressor
• Spine Fin™ outdoor coil for long lasting compartment.
performance and durability. • Standard operation to 55°F as manufactured.
• Right side electrical service for high and low • Low ambient cooling to 0°F with kit.
voltage lines. • UL approved and listed.
• Rugged steel basepan features deep drawn • 5 year compressor and 5 years other parts
duct connections and emergency drains. limited warranty. (Residential Use Only)
• All steel louvers and cabinet for rugged, long • Steeply sloped composite drainpan will • Optional extended warranty.
lasting protection. empty fast and never rust.
• Weather Beater Top contoured for great • Ships in horizontal configuration and
appearance and reinforced for strength. converts quickly for downflow.

Table PC-6-A — 4TCC–XB13c - Convertible Package Cooling - R-410A


Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER Weight MCA Fuse Rating H xW x L
4TCC – 208/230/1/60
4TCC3018A1000A 18,000 13.0/11.00 444 10.1 15 74 36 x 49 x 42
4TCC3024A1000A 23,000 13.0/11.00 444 13.6 20 76 36 x 49 x 42
4TCC3030A1000A 28,000 13.0/11.00 445 21.7 35 75 36 x 49 x 42
4TCC3036A1000A 35,000 13.0/11.00 450 23.2 35 76 36 x 49 x 42
4TCC3042A1000A 40,000 13.0/11.00 523 27.9 45 78 38 x 59 x 44
4TCC3048A1000A 46,500 13.0/11.00 607 31.1 50 80 38 x 59 x 44
4TCC3060A1000A 58,000 13.0/11.00 610 43.3 60 79 40 x 59 x 44
4TCC – 208/230/3/60
4TCC3036A3000A 35,000 13.0/11.00 450 18.2 30 76 36 x 49 x 42
4TCC3048A3000A 46,500 13.0/11.00 607 23.6 35 80 38 x 59 x 44
4TCC3060A3000A 58,000 13.0/11.00 610 31.5 50 79 40 x 59 x 44
4TCC – 460/3/60
4TCC3036A4000A 35,000 13.0/11.00 450 8.7 15 76 36 x 49 x 42
4TCC3048A4000A 46,500 13.0/11.00 607 11.7 15 80 38 x 59 x 44
4TCC3060A4000A 58,000 13.0/11.00 610 19.3 25 79 40 x 59 x 44

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PC-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCC3018A through 4TCC3036A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCC3018A through 4TCC3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PC-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCC3042A through 4TCC3060A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCC3042A through 4TCC3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PC-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

4TCX3 4TCC3
Table PC-11-A — Accessories 1½-5 1½-5
BAYADAP050A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 1½-3 1½-3
BAYADAP051A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 1½-3 1½-3
BAYADAP052A ...... Adapter Curb (Cabinet A/B) ............................................................................................................................ 3½-5 3½-5
BAYADAP053A ...... Adapter Curb (Cabinet C) ............................................................................................................................... 3½-5 3½-5
BAYADAP054A ...... Adapter Curb (Cabinet D) ............................................................................................................................... 3½-5 3½-5
BAYCCHT101A ..... Crankcase Heater (230V) .............................................................................................................................. 1½-2 1½-2
BAYCCHT102A ..... Crankcase Heater (230V) .............................................................................................................................. 2½-5 2½-5
BAYCCHT104A ..... Crankcase Heater (460V) .............................................................................................................................. 3,4,5 3,4,5
BAYCOVR112A ..... 12" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3
BAYCOVR118A ..... 18" Duct Shourd (Covers Horizontal Ducts)0 ................................................................................................. 1½-3 1½-3
BAYCURB050A ..... Flat Roof Curb (Insulated)5 ........................................................................................................................... 1½- 3 1½- 3
BAYCURB051A ..... Flat Roof Curb (Insulated)6 ........................................................................................................................... 3½-5 3½-5
BAYDMPR101A ..... 2-Position Motorized Damper ......................................................................................................................... 1½- 3 1½- 3
BAYDMPR102A ..... 2-Position Motorized Damper ......................................................................................................................... 3½-5 3½-5
BAYECON101A ..... Economizer with Barometric Relief1347 .................................................................................................... 1½- 3 1½- 3
BAYECON102A ..... Economizer with Barometric Relief1347 .................................................................................................... 3½-5 3½-5
BAYECON200A ..... Economizer (Horizontal)137 ........................................................................................................................ 1½- 3 1½- 3
BAYECON201A ..... Economizer (Horizontal)137 ........................................................................................................................ 3½-5 3½-5
BAYENTH100A ..... Enthalpy Control Kit3 ..................................................................................................................................... ✔ ✔
BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ............................................................. ✔ ✔
BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .................................................................................... ✔ ✔
BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................................................................... ✔ ✔
BAYFLTR101A ....... 1-2" Filter Frame1 .......................................................................................................................................... 1½- 3 1½- 3
BAYFLTR201A ....... 1-2" Filter Frame1 .......................................................................................................................................... 3½-4 3½-4
BAYLIFT002BA ..... Lifting Lug Kit ................................................................................................................................................. ✔ ✔
BAYLOAM011A ..... Evaporator Defrost Control Kit ........................................................................................................................ ✔ ✔
BAYLOAM105A ..... Low Ambient Control Kit ................................................................................................................................. ✔ ✔
BAYOSAH001A ..... Manual Fresh Air Damper14 ........................................................................................................................ 1½-3 1½-3
BAYOSAH002A ..... Manual Fresh Air Damper14 ........................................................................................................................ 3½-5 3½-5
BAYQSTK300A ..... Quick Start Kit .............................................................................................................................................. 1 Phase Only 1 Phase Only
BAYSQRD001A ..... 16" Round Duct Adapter9 ............................................................................................................................. 1½-3 1½-3
BAYSQRD002A ..... 18" Round Duct Adapter9 ............................................................................................................................. 1½-5 1½-5
BAYUTIL101A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 1½-3 1½-3
BAYUTIL102A ....... Roof Curb Utility Extension Kit ........................................................................................................................ 3½-5 3½-5
1 Must use filter frame when economizer/fresh air kit is used.
2 Ships knocked down.
3 Dry bulb control standard with economizer.
4 Downflow Only.
5 Full perimeter curb for 4TC*3018-036A.
6 Full perimeter curb for 4TC*3042-060A.
7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.
8 Do not use with programmable thermostats.
9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
0 BAYCOVR112,118A will not cover BAYSQRD002A applications

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

Table PH-12-A — Supplementary Heaters – Separate power source /power entry required
Model Shipping
Number Description Used With Weight
BAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 4TC*3018-060A1 9
BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 4TC*3024-060A1 10
BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 4TC*3030-060A1 14
BAYHTRV120A 15.00/20.0 kW Heater (208/240V 1PH) 4TC*3048-060A1 14
BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 4TC*3018-060A3 9
BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 4TC*3024-060A3 10
BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 4TC*3030-060A3 14
BAYHTRV320A 15.0/20.0 kW Heater (208/240V 3PH) 4TC*3048-060A3 14
BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 4TC*3018-060A4 9
BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 4TC*3024-060A4 10
BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 4TC*3030-060A4 14
BAYHTRV420A 15.0/20.0 kW Heater (460V 3PH) 4TC*3048-060A4 14

Table PH-12-B — Single Power Entry Kit/Heater Matrix:


Single Power Heater Unit Shipping
1
Entry Kit1 Model Model Weight
BAYSPEK060A BAYHTRV105A 4TC*3018-048A1 3
BAYHTRV110A 4TC*3024-048A1
BAYSPEK061A BAYHTRV305A 4TC*3036-060A3 7
BAYHTRV310A 4TC*3036-048A3
BAYHTRV315A 4TC*3036-060A3
BAYHTRV405A 4TC*3036-060A4
BAYHTRV410A 4TC*3036-060A4
BAYHTRV415A 4TC*3036-060A4
BAYHTRV420A 4TC*3048-060A4
BAYSPEK062A BAYHTRV105A 4TC*3060A1 7
BAYHTRV110A 4TC*3060A1
BAYSPEK063A BAYHTRV115A 4TC*3030-060A1 7
BAYHTRV120A 4TC*3048-060A1
BAYSPEK064A BAYHTRV320A 4TC*3048-060A3 6
1 All necessary fuses are included in kit

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PC-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 2 through 5 Tons

TCY — XL 1400 TCX — XL 1200

XL1400

Table PC-13-A — TCY – XL 1400 Convertible Package Cooling


Cooling Cabinet Supply/Return Supply /Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER* (Btuh) H x Wx L WxL H xW (Ibs.) MCA* Fuse* Rating Compressor
TCY – 208-230/1/60
TCY024G100B 14.00/12.00 24,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 371 15.9 25 80 R1

PHASED OUT
TCY030G100A 13.00/11.00 30,600 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 382 21.4 30 80 R2
TCY036G100A 14.10/12.00 36,000 29 x 36 x 64 (C) 171/2 x 10 189/16 x 111/16 448 24.8 35 80 R2
TCY042G100A 14.00/11.70 41,500 29 x 36 x 64 (C) 171/2 x 10 189/16 x 111/16 448 26.7 40 80 R2
TCY048G100A 14.40/12.20 49,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 561 32.7 50 84 R2
TCY060G100A 13.00/11.00 61,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 566 46.8 60 84 S

Table PC-13-B — TCX – XL 1200 Convertible Package Cooling


Cooling Cabinet Supply/Return Supply /Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER* (Btuh) H x Wx L WxL H xW (Ibs.) MCA* Fuse* Rating Compressor
TCX – 208-230/1/60
TCX024G100B 12.00/10.50 24,500 25 x 36 x 56 (A) 171/2 x 10 189/16 x 111/16 351 14.6 20 80 R1
TCX030G100A 12.05/10.90 30,600 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 363 21.2 30 80 S
TCX036G100A 12.05/10.50 37,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 24.4 40 80 S
TCX042G100A 12.05/10.55 43,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 384 26.8 40 80 S
TCX048G100A 12.50/11.45 48,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 31.9 50 84 S
TCX060G100A 12.05/10.55 61,500 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 45.0 70 84 S
TCX – 208-230/3/60
TCX036G300A
TCX042G300A
TCX048G300A
TCX060G300A
PHASED OUT
12.05
12.05
12.50
12.05
37,000
43,000
48,000
61,500
29 x 36 x 56 (B)
29 x 36 x 56 (B)
33 x 45 x 65 (D)
33 x 45 x 65 (D)
171/2 x 10
171/2 x 10
20 x 14
20 x 14
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
211/16 x 151/16
374
384
480
507
17.4
19.9
24.5
30.6
25
30
35
45
80
80
84
84
S
S
S
S
TCX – 460/3/60
TCX036G400A 12.05 37,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 10.0 15 80 S
TCX048G400A 12.50 48,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 15.4 20 84 S
TCX060G400A 12.05 61,500 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 15.1 20 84 S
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

TCP — XE 1200
TCC — XE 1000

Table PC-14-A — TCP – XE 1200 Convertible Package Cooling


Cooling Cabinet Supply/Return Supply /Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER* (Btuh) H x Wx L WxL H xW (Ibs.) MCA* Fuse* Rating Compressor
TCP – 208-230/1/60
TCP024F100B 12.10/10.50 24,500 25 x 36 x 56 (A) 171/2 x 10 189/16 x 111/16 351 14.6 20 80 R1
TCP030F100A 12.00/10.90 30,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 363 21.2 30 80 S
TCP036F100A 12.00/10.50 36,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 24.4 40 80 S
TCP042F100A 12.00/11.45 42,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 384 26.8 40 80 S
TCP048F100A 12.20/11.45 47,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 31.9 50 84 S
TCP060F100A 12.00/10.55 60,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 45 70 84 S
TCP – 208-230/3/60
TCP036F300A
TCP042F300A
TCP048F300A
TCP060F300A
12.00
12.00
12.20
12.00
PHASED OUT 36,000
42,000
47,000
60,000
29 x 36 x 56 (B)
29 x 36 x 56 (B)
33 x 45 x 65 (D)
33 x 45 x 65 (D)
171/2 x 10
171/2 x 10
20 x 14
20 x 14
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
211/16 x 151/16
374
384
480
507
17.4
19.9
24.5
30.6
25
30
35
45
80
80
84
84
S
S
S
S
TCP – 460/3/60
TCP036F400A 12.00 36,000 29 x 36 x 56 (B) 171/2 x 10 189/16 x 111/16 374 10 15 80 S
TCP048F400A 12.20 47,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 480 15.4 20 84 S
TCP060F400A 12.00 60,000 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 507 15.1 20 84 S

Table PC-14-B — TCC – XE 1000 Convertible Package Cooling


Cooling Cabinet Supply/Return Supply /Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER* (Btuh) H x Wx L WxL H xW (Ibs.) MCA* Fuse* Rating Compressor
TCC – 208-230/1/60
TCC018F100B 10.00/9.35 18,000 25 x 36 x 55 (A) 171/2 x 10 189/16 x 111/16 319 15.0 20 80 R1
TCC024F100B 10.00/9.10 23,400 25 x 36 x 55 (A) 171/2 x 10 189/16 x 111/16 327 17.7 25 80 R1

PHASED OUT
TCC030F100B 10.00/9.10 29,800 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 354 22.7 35 80 R1
TCC042F100B 10.00/8.60 40,500 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 389 31.2 50 80 R2
TCC048F100B 10.00/9.25 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 37.0 55 84 R2
TCC060F100B 10.00/9.20 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 43.9 70 84 R2

TCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.


TCC036F300B 10.00 35,400 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 369 19.9 30 80 R1/2
TCC042F300B 10.00 40,500 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 389 22.9 35 80 R2
TCC048F300B 10.00 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 27.0 40 84 R2
TCC060F300B 10.00 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 31.0 45 84 R2
TCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.
TCC036F400B 10.00 35,400 29 x 36 x 55 (B) 171/2 x 10 189/16 x 111/16 369 10.5 15 80 R1/2
TCC048F400B 10.00 48,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 513 12.7 20 84 R2
TCC060F400B 10.00 60,000 33 x 45 x 64 (D) 20 x 14 211/16 x 151/16 547 16.3 25 84 R2
* Information subject to change. Please confirm with current For information on Roof Curbs and
Product Data/Service Facts for current factory production. Roof Curb Adaptors, please refer to
Note: TCC-F models currently manufactured with sloped drain pans. the Accessories/Information Tab.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
For complete equipment / combination
Effective 1/1/06 PC-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

A
B

EVAPORATOR COIL &


SUPPLY & BLOWER PANEL
RETURN PANEL

ECONOMIZER/FILTER
ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H

D
J D 29 MM
35 MM L (1 1/8")
M X
(1 3/8") X
Y
Y CONDENSATE DRAIN
L 19 MM (3/4") FEMALE NPT
K M
DOWNFLOW
HORIZONTAL RETURN OPENING
SUPPLY P
76 MM
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING

Table PC-15-A — TCY – XL 1400 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
TCY024G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 253/8 171/2 10 3 47/16 30A, 38A

PHASED OUT
TCY030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38A
TCY036G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33A
TCY042G 64 36 291/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33A
TCY048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 251/4 281/2 20 14 31/2 85/16 30A, 38A, 34A
TCY060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 251/4 281/2 20 14 31/2 85/16 30A, 38A, 34A

Table PC-15-B — TCX – XL 1200 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
TCX024G 561/2 36 253/16 189/16 111/16 69/16 613/16 17 21 241/4 171/2 10 3 47/16 30A, 38A

PHASED OUT
TCX030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 247/8 171/2 10 3 47/16 30A, 38A
TCX036G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 251/4 171/2 10 3 47/16 30A, 38A
TCX042G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 257/8 171/2 10 3 47/16 30A, 38A
TCX048G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 301/4 20 14 31/2 85/16 30A, 38A,34A
TCX060G 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/16 287/8 20 14 31/2 85/16 30A, 38A,34A

Table PC-15-C — TCP – XE 1200 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
TCP024F 561/2 36 253/16 189/16 111/16 69/16 613/16 17 21 241/4 171/2 10 3 47/16 30A, 38A

PHASED OUT
TCP030F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 247/8 171/2 10 3 47/16 30A, 38A
TCP036F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 251/4 171/2 10 3 47/16 30A, 38A
TCP042F 561/2 36 293/16 189/16 111/16 69/16 613/16 17 201/2 257/8 171/2 10 3 47/16 30A, 38A
TCP048F 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 301/4 20 14 31/2 85/16 30A, 38A,34A
TCP060F 651/4 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/16 287/8 20 14 31/2 85/16 30A, 38A,34A

Table PC-15-D — TCC – XE 1000 Dimensional Data - Limited Availability 3 Phase Only, 2006
Model A B C D E F G H J K L M N P BAYCURB0
TCC018F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 251/2 171/2 10 3 47/16 30A, 38A
TCC024F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 251/2 171/2 10 3 47/16 30A, 38A
TCC030F
TCC036F
TCC042F
TCC048F
TCC060F
551/4
551/4
551/4
645/16
645/16
PHASED OUT
36
36
36
45
45
293/16
293/16
293/16
333/8
333/8
189/16
189/16
189/16
211/16
211/16
111/16
111/16
111/16
151/16
151/16
69/16
69/16
69/16
415/16
415/16
613/16
613/16
613/16
91/8
91/8
17
17
17
2115/16
2115/16
203/16
185/8
19
245/8
245/8
255/16
243/16
24
281/2
281/2
171/2
171/2
171/2
20
20
10
10
10
14
14
3
3
3
31/2
31/2
47/16
47/16
47/16
85/16
85/16
30A, 38A
30A, 38A
30A, 38A
30A, 38A, 34A
30A, 38A, 34A
Note: TCC-F models currently manufactured with sloped drain pans.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PC-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
1½ through 5 Tons

TCY-G TCX-G TCP-F TCC-F


Table PC-16-A — Features 2-5 Ton 2-5 Ton 2-5 Ton 11/2-5 Ton

T
• Impack Plus™ feature set .............................................................................................................. ✔ ✔ ✔ ✔

U
• Climatuff® Compressor (1) .............................................................................................................. ✔ ✔ ✔ ✔
• Comfort-RTM mode option ............................................................................................................... ✔ — — —

O
• Coil Sav’RTM coil guard ................................................................................................................... ✔ ✔ — —
• Direct drive two-speed fan motor ..................................................................................................... ✔ — — —

ED
• GE ECM variable speed fan motor .................................................................................................. — — —
• Heavy vinyl - coated coil guard ........................................................................................................ — — ✔ —
• Horizontal convertible to downflow .................................................................................................. ✔ ✔ ✔ ✔
• Plate Fin coil .................................................................................................................................... ✔ ✔ ✔ ✔

AS
• Polarized plugs ................................................................................................................................ ✔ ✔ ✔ ✔
• Powder paint .................................................................................................................................... ✔ ✔ ✔ ✔
• 5-year limited compressor only warranty (Commercial use) ............................................................ ✔ ✔ ✔ ✔

PH
• 5-year limited compressor, coil and parts warranty (Residential use) ............................................. — — ✔ ✔
• 5-year limited parts warranty (Residential use) ............................................................................... ✔ ✔ — —
• 1-year limited coil and parts warranty (Commercial use) ................................................................ ✔ ✔ ✔ ✔
• 10-year limited compressor and outdoor coil warranty (Residential use) ........................................ ✔ ✔ — —

Table PC-16-B — Comfort Controls


AY28X092 ............... Heat/Cool (Horizontal) ....................................................................................... ✔ ✔ ✔
BAY28X1821 .......... 1-Stage Heating/Cooling .................................................................................... ✔ ✔ ✔
BAY28X1831 .......... 2-Stage Heating/Cooling .................................................................................... ✔ ✔ ✔
BAY28X1842 .......... Subbase Auto/Manual Changeover ................................................................... ✔ ✔ ✔
BAY28X1853 .......... Subbase Manual Changeover ........................................................................... ✔ ✔ ✔
BAY28X1872 .......... Subbase Auto Changeover ................................................................................ ✔ ✔ ✔

T
BAY28X190 ............. Locking Thermostat Cover ................................................................................. ✔ ✔ ✔

U
BAYSTAT0102 ........ Auto 2-Stage Heating/2 Cooling with Economizer ............................................. ✔ ✔ ✔
Zone Sensors Section
See Comfort Controls/

BAYSTAT0082 ........ Manual 1-Stage Heating/1 Cooling .................................................................... ✔ ✔ ✔

O
BAYSTAT0122 ........ Manual 1-Stage Heating/2 Cooling w/economizer ............................................. ✔ ✔ ✔
BAYSTAT033A ........ Outdoor Thermostat ........................................................................................... ✔ ✔ ✔

ED
BAYSTAT253A ........ Humidity Control ................................................................................................ — — —
BAYSTAT304 ........... Cooling Only with Fan Switch ............................................................................ ✔ ✔ ✔
BAYSTAT305 ........... Heat/Cool Vertical .............................................................................................. ✔ ✔ ✔
✔ ✔ ✔
AS
TAYSENS100A ........ Outdoor Temp. Sensor (with case)4 ..................................................................
TAYSTAT300C ......... XT 300C Prog.,7 Day,A/M 1Htg/1Clg ................................................................ ✔ ✔ ✔
TAYSTAT302C ......... XT 302C Prog.,7 Day,A/M 2Htg/2Clg ................................................................ ✔ ✔ ✔
✔ ✔ ✔
PH

TAYSTAT340 ........... Prog., 5/2 Day, Manual Thermostat ...................................................................


TAYSTAT3713 ......... Electronic 1Htg(Elec)/1Clg (Non Prog) .............................................................. ✔ ✔ ✔
TCONT200 .............. 1Heat/1Clg (Gas, Oil or Electric) ....................................................................... ✔ ✔ ✔
TCONT401 .............. 2Heat/1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT402 .............. 3Heat/2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT600 .............. 1Heat/1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT602 .............. 2Heat/2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT800 .............. 1Heat/1Clg (Gas, Oil or Electric) ....................................................................... ✔ ✔ ✔
1 Requires Subbase.
2 Requires BAY24X042 relay kit when used with electric heat.
3 Specifically designed for electric heat applications (instant on fan).
4 Used with TAYSTAT300C, TAYSTAT302C.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PC-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

Table PC-17-A — Supplementary Heaters – Single Point Entry Kit/Heater Matrix


Used With Single Used With
Model No. Description Power Entry Kit1 Packaged Cooling Unit
BAYHTRN105A ..... 3.74/4.98 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC018-042F1,TCP024-042F1,TCY/TCX024-42G1
BAYHTRN108A ..... 5.76/7.68 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC018-042F1, TCP024-042F1, TCY/TCX024-42G1
BAYHTRN110A ..... 7.47/9.96 kW Heater (208/240V 1PH) .......... BAYSPEK047A ....... TCC/TCP024-048F1, TCY/TCX024-60G1
BAYSPEK053A ....... TCC/TCP060F1,TCY/TCX060G1
BAYHTRN112A ..... 8.65/11.52 kW Heater (208/240V 1PH) ........ BAYSPEK049A ....... TCC/TCP024-048F1, TCY/TCX024-48G1
BAYSPEK053A ....... TCC/TCP060F1,TCY/TCX060G1
BAYHTRN115A ..... 11.21/14.94 kW Heater (208/240V 1PH) ...... BAYSPEK048A ....... TCC/TCP030-048F1, TCY/TCX030-048G1
BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1
BAYHTRN117A ..... 12.98/17.28 kW Heater (208/240V 1PH) ...... BAYSPEK048A ....... TCC/TCP030-048F1, TCY/TCX030-060G1
BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1
BAYHTRN123A ..... 17.2/23.04 kW Heater (208/240V 1PH) ........ BAYSPEK048A ....... TCC/TCP030-48F1,TCY/TCX048G1
BAYSPEK052A ....... TCC/TCP060F1,TCY/TCX060G1
BAYHTRN306A ..... 4.89/6.25 kW Heater (208/240V 3PH) .......... BAYSPEK047A ....... TCC//TCP036-060F3,TCX036-060G3
BAYHTRN310A ..... 7.45/9.96 kW Heater (208/240V 3PH) .......... BAYSPEK047A ....... TCC/TCP036-060F3,TCX036-060G3
BAYHTRN315A ..... 11.25/14.90 kW Heater (208/240V 3PH) ...... BAYSPEK047A ....... TCC/TCP036-060F3,TCX036-060G3
BAYHTRN320A ..... 14.96/19.92 kW Heater (208/240V 3PH) ...... BAYSPEK051A ....... TCC/TCP042-060F3/TCX042-060G3
BAYHTRN330A ..... 22.41/29.80 kW Heater (208/240V 3PH) ...... BAYSPEK050A ....... TCC/TCP060F3,TCX060G3
BAYHTRN406A ..... 6kW Heater (480V 3PH) ............................. BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4
BAYHTRN410A ..... 9.96 kW Heater (480V 3PH) ....................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4
BAYHTRN410F ..... 9.96 kW Heater (480V 3PH) ....................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4
BAYHTRN415A ..... 14.90 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP036-060F4,TCX036-060G4
BAYHTRN420A ..... 19.92 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP048-060F4,TCX036-060G4
BAYHTRN430A ..... 29.80 kW Heater (480V 3PH) ..................... BAYSPEK047A ....... TCC/TCP060F4,TCX060G4
1 All necessary fuses are included in kit

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Convertible 1½ through 5 Tons

TCY-G TCX-G TCP-F TCC-F


Table PC-18-A — Accessories 2-5 2-5 2-5 1½-5
BAY24X045 ........... DPDT Relay .................................................................................................... — — — 1½-5
BAYASCT001 ........ Anti-Short Cycle Timer69 .............................................................................. 2-5 2-5 2-5 1½-5
BAYCCHT003A ..... Crankcase Heater, 230V7 .............................................................................. 2-4 2-5 2-5 1½-5
BAYCCHT202A ..... Crankcase Heater (230v) ................................................................................ 5 2½-5 2½-5 —
BAYCCHT400A ..... Crankcase Heater (460v) ................................................................................. 3-5 3-5 3-5 —
BAYCURB030A ..... Roof Curb (Flat Roof)2 (14 H x 34 W x 53 1/8 L) ............................................ 2-5 2-5 2-5 1½-5

T
BAYCURB033A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 60 5/8 L) ...................... 3-3½ — — —
BAYCURB034A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 43 W x 62 1/16 L) .................... 4-5 4-5 4-5 4-5
BAYCURB038A ..... Roof Curb (Flat Roof)2 Acousti-Curb (14 H x 34 W x 53 1/8 L) ...................... 2-5 2-5 2-5 1½-5
BAYDMPR040A ..... 0-25% Manual Fresh Air Damper14 .............................................................. 2-3½ 2-3½ 2-3½ 1½-3½

OU
BAYDMPR041A ..... 0-25% Manual Fresh Air Damper14 .............................................................. 4-5 4-5 4-5 4-5
BAYDMPR050A ..... Motorized Fresh Air Damper1 ....................................................................... 4-5 4-5 4-5 4-5
BAYDUCT004A ..... 12" Round Duct Adapters (2 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½
BAYDUCT005A ..... 14" Round Duct Adapters (1 per Box) ............................................................. 2-3½ 2-3½ 2-3½ 1½-3½
BAYECMT002A ..... Extreme Conditions Mounting Kit (Curb Mount) ............................................... 2-5 2-5 2-5 1½-5
BAYECMT003A ..... Extreme Conditions Mounting Kit (Slab or Rack Mount) ................................. 2-5 2-5 2-5 1½-5
BAYECON054B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 2-3½ 2-3½ 2-3½ 1½-3½
BAYECON055B ..... 0-100% Mod. Economizer with Bar Relief1345 ............................................ 4-5 4-5 4-5 4-5
BAYECON073A ..... 0-100% Mod. Economizer – Horizontal135 ................................................... 2-5 2-5 2-5 1½-5
BAYENTH001A ..... Enthalpy Control (Solid State)3 ...................................................................... 2-5 2-5 2-5 1½-5
BAYFLTR012A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 2-2½ 2-3½ 2½-3½ 2½-3½

ED
BAYFLTR013A ....... Filter Frame1 (20 x 25 x 1" filter not included) ................................................ 3-3½ — — —
BAYFLTR014A ....... Filter Frame1 (3-10 x 25 x 1" filter not included) ............................................. 4-5 4-5 4-5 4-5
BAYFLTR015A ....... Filter Frame1 (20 x 20 x 1" filter not included) ................................................ — 2-5 2 1½-2
BAYFLTR017A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 2-2½ 2-3½ 2½-3½ 2½-3½
BAYFLTR018A ....... Filter Frame1 (1-20 x 25 x 2" filter not included) ............................................. 3-3½ — — —
BAYFLTR019A ....... Filter Frame1 (2-16 x 25 x 2" filter not included) ............................................. 4-5 4-5 4-5 4-5
BAYGARD016A ..... Condenser Coil Guard ..................................................................................... — — — 1½-2
1
BAYGARD017A ..... Condenser Coil Guard .....................................................................................
BAYGARD018A ..... Condenser Coil Guard .....................................................................................
BAYGARD021A ..... Condenser Coil Guard .....................................................................................
BAYHSMT043A ..... High Static Motor (230/460V) 3/4HP ................................................................
BAYHSMT044A ..... High Static Motor (230/460V) 1HP ...................................................................





AS —


2½-3½
4



2½-3½
4-5
3 /2
2½-3
4-5
2½-3½
4-5
BAYHSMT045A ..... High Static Motor (208V) 1HP ......................................................................... — 4 4-5 4-5
BAYHSMT056A ..... High Static Motor (208V) 3/4HP ...................................................................... — 2½-3½ 2½-3½ 2½-3½
BAYINDK001A* ..... Insulated Deck Pan for A & B Cabinet ............................................................. 2-5 2-5 2-5 1½-5
PH
BAYINDK002A** .... Insulated Deck Pan for C Cabinet .................................................................... 2-3½ — — —
BAYINDK003A*** ... Insulated Deck Pan for D Cabinet .................................................................... 4-5 4-5 4-5 4-5
BAYKSKT010A ...... Quick Start Kit (Single Phase Models Only) .................................................... — — — 1½-5
BAYKSKT254 ........ Start Kit - Scroll Models Only(Single Phase Models Only) ............................... — 2½-4 2½-4 —
BAYLIFT002B ........ Lifting Lug Kit .................................................................................................. 2-5 2-5 2-5 1½-5
BAYLOAM011A ..... Evaporator Defrost Control Kit ......................................................................... 2-5 2-5 2-5 1½-5
BAYLOAM323A ..... Dual Voltage Elec. Head Pressure Control (208-230V or 460V)78 .................... 2-5 2-5 2-5 1½-5
BAYMOTR307A ..... 200-230V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) .................. 2-3½ 2-5 2-5 1½-5
BAYMOTR406A ..... 460V 1/2HP Ball Bearing OD Motor (use with BAYLOAM323A) ......................... — 3-5 3-5 1½-5
BAYRLAY002 ......... Time Delay Relay ............................................................................................ 2-5 2-5 2-5 —
BAYSTAT023 ......... Remote Potentiometer for BAYECON054B, 055B, 073A ................................. 2-5 2-5 2-5 1½-5
BAYUTIL030A ....... Roof Curb Utility Extension Kit for BAYCURB030A, 038A ................................ — — — 1½-5
BAYUTIL033A ....... Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — —
BAYUTIL034A ....... Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — 4-5
1 Must use filter frame when economizer/fresh air kit is used. 7 Low ambient cooling requires crankcase heater.
2 Ships knocked down. 8 May require motor change. (See Installers Guide.)
3 Dry bulb control standard with economizer. 9 Activated on Power On.
4 Downflow Only. * Currently Shipped with BAYCURB038A.
5 2-Stage thermostat provides additional energy savings if ** Currently Shipped with BAYCURB033A.
simultaneous economizer and compressor operation is expected. *** Currently Shipped with BAYCURB034A.
6 Do not use with programmable thermostats.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PC-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling/Electric Heat
2 through 4 Tons

• Climatuff® compressor • Heavy gauge steel cabinet


• Weather resistant Powder Paint
• Compressor motor overload protection
• Double powder painted G90 base pan with
• Internal pressure relief valve
• Copper tube, aluminum plate fin coils dimpled feet
• Wrap-around vinyl-coated wire coil guards
• Shaft-Down OD fan system for quiet
• U.L. listed
operation (good neighbor)
• Sloped composite drain pan • 5-year limited warranty on compressor and
• Waterproof closed-cell foam evaporator 5-year on all other parts (Residential use)
TCK • Optional extended warranties
base insulation

Table PC-19-A — XE 1200 — Cooling - Single Phase (208/230/1/60)


Cooling Round Round Shipping
Unit Capacity Dimensions (in.) Supply Return Weight Sound
Tons Model No. SEER/EER* (Btuh) H x W x L Opening Opening (Ibs.) Rating Compressor
2 TCK024A100B 12.00/10.49 24,000 31 x 32 x 44 (**) 14" 14" 334 73 R1
21/2 TCK030A100B 12.00/10.62 30,000 31 x 32 x 44 (**) 14" 14" 341 73 S
3 TCK036A100B 12.00/10.63 36,000 31 x 32 x 44 (**) 14" 14" 343 73 S
31/2 TCK042A100B 12.00/10.45 41,000 31 x 32 x 44 (**) 14" 14" 351 73 S
31/2 TCK042A1H0B 12.00/10.45 41,000 31 x 32 x 44 (**) 14" 14" 351 73 S
4 TCK048A100B 11.80/10.33 45,000 31 x 32 x 44 (**) 14" 14" 372 73 S

Table PC-19-B — Electric Heater Data


Using Single Supply Circuit
TCK Cooling/HTG Heater Only Supply Circuit
Max Fuse Canada Only Max Fuse Canada Only
Unit Electric Rated Heater kW or HACR CKT Max. CKT or HACR CKT Max. CKT
Model No. Heater Model Voltage 208/240 2
MCA2 BKR Size44 5
BKR Size5 6
MCA6 4
BKR Size4 BKR Size55
TCK024A1 BAYHTRK105A 208/240 3.74/4.98 25/293 25/30 30/30 23/26 25/30 30/30
BAYHTRK110A 208/240 7.48/9.96 47/553 50/60 50/60 45/52 45/60 50/60
TCK030A1 BAYHTRK105A 208/240 3.74/4.98 25/293 25/30 30/30 23/26 25/30 30/30
BAYHTRK110A 208/240 7.48/9.96 48/553 50/60 50/60 45/52 45/60 50/60
TCK036A1 BAYHTRK105A 208/240 3.74/4.98 25/293 25/30 30/30 23/26 25/30 30/30
BAYHTRK110A 208/240 7.48/9.96 48/553 50/60 50/60 45/52 45/60 50/60
TCK042A1 BAYHTRK105A 208/240 3.74/4.98 27/303 30/30 30/30 23/26 25/30 30/30
BAYHTRK110A 208/240 7.48/9.96 49/563 50/60 50/60 45/52 45/60 50/60
BAYHTRK115A 208/240 11.22/14.94 71/813 80/90 100/100 68/78 70/80 70/100
TCK048A16 BAYHTRK106A 208/240 3.74/4.98 26/303 30/30 30/30 23/26 25/30 30/30
BAYHTRK110A 208/240 7.48/9.96 50/603 50/60 50/60 45/52 45/60 50/60
BAYHTRK115A 208/240 11.22/14.94 71/813 80/90 100/100 68/78 70/80 70/100
NOTES:
1 Any power supply and circuits must be wired and protected in accordance with local electrical codes.
2 The MCA values listed are for electric heater and cooling unit.
3 Field wire must be rated at least 75°C.
4 The HACR circuit breaker is for U.S.A. installations only.
5 For Canada installation reference only
6 BAYHTRK106A only approved for TCK048A1
7 The MCA values listed are for electric heater only.
8 The MCA values listed are for electric heater and heat pump.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

TCK-A models will be upgraded in the 1st Quarter of 2006.

For complete equipment / combination


selections and installation instructions, please PC-19 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling/Electric Heat
2 through 4 Tons

Table PC-20-A — Accessories/Comfort Controls


Model No. Description Used With
AY28X092 Heat/Cool (Horizontal) Therm. All Cooling Models
BAY28X1821 1-Stage Heating/Cooling Therm. All Cooling Models
BAY28X1831 2-Stage Heating/Cooling Therm. All Cooling Models
BAY28X1842 Subbase Auto/Man. Changeover BAY28X183
BAY28X1853 Subbase Man. Changeover BAY28X182,183
BAY28X1872 Subbase Auto Changeover BAY28X182,183
BAY28X1904 Locking Thermostat Cover All Room Thermostats
BAYCOVR100A Wallcover Plate TAYSTAT371
BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All TCK Models
BAYECMT003A Extreme Conditions Mounting Kit (Slab and Rack Mount) All TCK Models
BAYSTAT304 Cooling only with Fan Switch All Cooling Models
BAYSTAT305 Heat/Cool Vertical All Cooling Models
TAYSENS100A Outdoor Temperature Sensor (with case) TAYSTAT300
TAYSTAT300C XT300C Prog.,7 Day,A/M,1Htg./Clg. All Cooling Models
TAYSTAT340 Prog.,5/2 Day,Manual,1 Htg./Clg. All Cooling Models
TAYSTAT3713 Electronic,1Htg(Elec)/1Clg (Non Prog) All Cooling Models
TCONT200A 1Heat/1Clg (Gas, Oil or Electric) All Cooling Models
TCONT401A 2Heat/1Clg (Heat Pump/A/C) All Cooling Models
TCONT402A 3Heat/2Clg (Heat Pump/A/C) All Cooling Models
TCONT600A 1Heat/1Clg (Heat Pump/A/C) All Cooling Models
1 Requires subbase.
2 Requires BAY24X042 relay when used with electric heaters.
3 Specially designed for electric heater application (instant on fan).
4 Not for use with programmable thermostats.
A/M = Automatic or Manual Changeover
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

TCK-A models will be upgraded in the 1st Quarter of 2006.

For complete equipment / combination


Effective 1/1/06 PC-20 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling – Manufactured
Housing 2½ through 4 Tons

• Climatuff® compressor • Sloped Drain Pan


• High efficiency performance • Fully charged R-22 system
• Round duct connections for Manufactured • Heavy gauge steel cabinet with weather
Housing resistant, baked enamel finish
• Quiet operating top condenser • Protected pressure taps for
air discharge refrigerant checks
• Copper tube/aluminum fin coils • Fully insulated air handling compartment
• Totally enclosed, permanently lubricated • Convenient access panels
condenser fan motor • 5-year limited compressor warranty
• Hermetically sealed compressor (Residential use)
with internal relief valve • 5-year limited coil and parts warranty
TCM • Two-Speed evaporator blower motor (Residential use)

Table PC-21-A — TCM (208-230/1/60)


Cooling Cabinet Round Round Shipping
Unit Capacity Dimensions (in.) Supply Return Weight Max Sound
Model No. SEER/EER* (Btuh) H x Wx L Opening Opening (Ibs.) MCA* Fuse* Rating Compressor
TCM030F100B 9.7/9.10 29,800 29 x 36 x 55 (B) 12 12 358 22.7 35 80 R1
TCM036F100B
TCM042F100B
TCM048F100B
9.7/8.75
9.7/8.60
9.7/8.90 PHASED OUT
35,200
40,500
46,500
29 x 36 x 55 (B)
29 x 36 x 55 (B)
29 x 36 x 63 (C)
12
14
14
12
14
14
380
383
461
26.8
31.8
33.0
45
50
50
80
80
82
R1
R2
R2

Table PC-21-B — Supplementary Heaters – Heater Matrix


Model No. Description Used With
BAYHTRN105A 3.74/4.98 kW Heater (208/240 volt) TCM030, 036, 042F
BAYHTRN108A 5.76/7.68 kW Heater (208/240 volt) TCM030, 036, 042F
BAYHTRN110A
BAYHTRN112A
BAYHTRN115A
BAYHTRN117A
PHASED OUT
7.47/9.96 kW Heater (208/240 volt)
8.65/11.52 kW Heater (208/240 volt)
11.21/14.94 kW Heater (208/240 volt)
12.98/17.28kW Heater (208/240 volt)
TCM030, 036, 042, 048F
TCM030, 036, 042F
TCM030, 036, 042F
TCM030, 036, 042, 048F

Table PC-21-C — Accessories


Model No. Description Used With
BAYCCHT003A Crankcase Heater (230 volt) All TCM-F Models
BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All TCM Models
BAYECMT003A Extreme Conditions Mounting Kit (Slab and Rack Mount) All TCM Models
BAYFLTR012A Filter Frame (20x25x1" filer not included) TCM030, 036, 042F

PHASED OUT
BAYFLTR013A Filter Frame (20x25x1" filer not included) TCM042F
BAYGARD017A Condenser Coil Guard TCM042, 048F
BAYGARD018A Condenser Coil Guard TCM030, 036F
BAYHSMT043A High Static Motor All TCM-F Models
BAYHSMT044A High Static Motor All TCM-F Models
BAYHSMT045A High Static Motor All TCM-F Models
BAYHSMT056A High Static Motor All TCM-F Models
BAYKSKT010A Quick Start Kit All TCM-F Models

Table PC-21-D — Comfort Controls


Model No. Description Used With
AY28X092 Heat/Cool Horizontal All TCM-F Models
BAYSTAT304 Cooling Only with Fan Switch All TCM-F Models

PHASED OUT
BAYSTAT305 Heat/Cool Vertical All TCM-F Models
BAYSTAT033A Outdoor Thermostat All TCM-F Models
TCONT200A 1Heat/1Clg All TCM-F Models
TCONT401A 2Heat/1Clg All TCM-F Models
TCONT402A 3Heat/2Clg All TCM-F Models
TCONT600A 1Heat/1Clg All TCM-F Models
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PC-21 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Cooling
Over/Under 2 through 5 Tons

Table PC-22-A — TCH – Over/Under Horizontal Unit


Power Supply Nom. Cap. Shipping
Unit Volts Cooling Dimensions (in.) Weight Max Sound
Model No. Phase/Hz SEER/EER* (Btuh) H x W x L (Ibs.) MCA* Fuse* Rating Comp.
Single Phase
TCH024B100B 208-230/1/60 12.05/11.00 24,000 303/8 x 315/8 x 44 319 17.2 25 79 R1
TCH030B100B 208-230/1/60 12.6/11.00 30,000 303/8 x 315/8 x 44 335 19.3 30 82 R2
TCH036B100C 208-230/1/60 12.0/11.30 36,000 303/8 x 315/8 x 44 370 25.5 40 82 R2
TCH TCH042B100B 208-230/1/60 12.5/11.00 41,500 303/8 x 315/8 x 44 374 24.1 40 82 R2
• Climatuff® compressor TCH048F100A 208-230/1/60 13.75/12.35 50,000 33 x 45 x 58 504 37 50 84 S
• Compressor motor TCH060F100A 208-230/1/60 13.00/11.45 62,000 33 x 45 x 58 509 47 60 84 S
overload protection
• Internal pressure relief Tons Supply H x W Return H x W
valve
2 – 31/2 83/8 x 273/8 163/4 x 273/8
• Copper tube, aluminum
plate fin coils 4–5 81/2 x321/32 1915/16 x 321/32
• Pressure taps for
refrigerant check Table PC-22-B — TCH – Over/Under Horizontal Unit
• Top discharge condens- Power Supply Nom. Cap. Dimensions Shipping
ing fan Unit Volts Performance Cooling (in.) Weight Max Sound
• Indoor fan relay Tons Model No. Phase/Hz SEER (Btuh) H x W x L (Ibs.) MCA* Fuse* Rating
• Top access to supple- Three Phase
mentary heater
3 TCH036B300C 208-230/3/60 11.4 36,000 303/8 x 315/8 x 44 370 17.8 25 82
• Polarized plug for easy
1
field connection of low 3 /2 TCH042B300B 208-230/3/60 12.5 41,500 303/8 x 315/8 x 44 374 18.1 25 82
voltage to supplementary
heaters 3 TCH036B400C 460/3/60 11.4 36,000 303/8 x 315/8 x 44 370 9.7 15 82
• Over (supply) under
31/2 TCH042B400B 460/3/60 12.5 41,500 303/8 x 315/8 x 44 374 9.9 15 82
(return) air
configuration
• Wrap around coil guard Tons Supply H x W Return H x W
• Expansion valve on 3 – 31/2 83/8 x 273/8 163/4 x 273/8
indoor coil Dimensions are in inches. See Outline Dimensions.
• Heavy gauge steel * Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
cabinet
• Multi-speed direct drive
blower Variable speed
direct drive blower motort Top Diagram Only
on TCH-048-060F models
• Factory installed coil
guard
• Low ambient cooling to
45° F as manufactured
• UL listed
• 5 year limited warranty
on compressor and 5
year on all other parts
(residential use only)
• Optional extended
warranties
• Energy Star Listed

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

311mm
[12-1/4]

LEFT SIDE
TCH-B models will be upgraded in
the 1st Quarter of 2006.
For complete equipment / combination
Effective 1/1/06 PC-22 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Cooling
Over/Under 2 through 5 Tons

Table PC-23-A — Supplementary Heaters – Heater Matrix


Model No. Power Supply kW Rating Used With
BAYHTRC106A 208/240/1/60 4.33/5.76 kW TCH024-042B100A, 048F, 060F100A
BAYHTRC108A 208/240/1/60 6.12/8.16 kW TCH024-042B100A
BAYHTRC110A 208/240/1/60 7.93/10.56 kW TCH048F1 only
BAYHTRC111A 208/240/1/60 7.93/10.56 kW TCH024-042B100A, 060F1
BAYHTRC112A 208/240/1/60 8.65/11.52 kW TCH024-042B100A
BAYHTRC117A1 208/240/1/60 12.98/17.28kW TCH030-042B100A, 048F, 060F1
BAYHTRC306A 208/240/3/60 4.33/5.76 TCH036-042B300A
BAYHTRC312A 208/240/3/60 8.65/11.52 TCH036-042B300A
BAYHTRC317A 208/240/3/60 12.98/17.28 TCH036-042B300A
BAYHTRC406A 480/3/60 5.76 TCH036-042B400A
BAYHTRC412A 480/3/60 11.52 TCH036-042B400A
BAYHTRC417A 480/3/60 17.28 TCH036-042B400A
Table PC-23-B — Accessories/Comfort Controls
Model No. Description Used With
AY28X092 ............................. Heat/Cool (Horizontal) Thermostat .......................................... All Cooling Models
BAY24X042 .......................... DPDT Fan and Electric Heat Relay ......................................... Auto Changeover T-Stat
BAY28X1822 ...................... 1-Stage Heating/Cooling Thermostat ...................................... All Cooling Models
BAY28X1843 ...................... Subbase Automatic/Manual Changeover ................................ BAY28X182
BAY28X1854 ...................... Subbase Manual Changeover ................................................. BAY28X182
BAY28X1873 ...................... Subbase Automatic Changeover ............................................. BAY28X182
BAY28X190 ......................... Locking Thermostat Cover ...................................................... All Room Thermostats
BAY41X171A ........................ 5 or 7 Minute Delay Relay ....................................................... All TCH Models
BAYASCT00156 ................. Anti-Short Cycle Timer ............................................................ All TCH Models
BAYECMT002A .................... Extreme Conditions Mounting Kit (Curb Mount) ...................... All TCH Models
BAYECMT003A .................... Extreme Conditions Mounting Kit (Slab and Rack Mount) ...... All TCH Models
BAYLOAM011A .................... Low Ambient Cooling Kit ......................................................... All TCH Models
BAYSTAT304 ........................ Cooling Only with Fan Switch .................................................. All Cooling Models
BAYSTAT305 ........................ Heat/Cool Vertical ................................................................... All Cooling Models
TAYASCT501A56 ................ Anti-Short Cycle Timer ............................................................ All Cooling Models
TAYSENS100A ..................... Outdoor Temp. Sensor (with case) .......................................... TAYSTAT300C,302C
TAYSTAT300C ....................... XT300C Prog.,7 Day,A/M,1Htg/1Clg ....................................... All Cooling Models
TCONT200A ......................... 1Heat/1Clg (Gas, Oil or Electric) ............................................. All Cooling Models
TCONT401A ......................... 2Heat/1Clg (Heat Pump/A/C) .................................................. All Cooling Models
TCONT402A ......................... 3Heat/2Clg (Heat Pump/A/C) .................................................. All Cooling Models
TCONT600A ......................... 1Heat/1Clg (Heat Pump/A/C) .................................................. All Cooling Models
1 This model has a fuse box factory installed.
2 Requires subbase.
3 Requires BAY24X042 relay when used with electric heaters.
4 Specially designed for electric heater application (instant on fan).
5 Not for use with programmable thermostats.
6 Activated on Power Off.

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

TCH-B models will be upgraded 422mm


[16-5/8]

in the 1st quarter of 2006.

RIGHT SIDE
For complete equipment / combination
selections and installation instructions, please PC-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ 3-10 ton
Packaged Cooling

Standard Features:
• Trane built scroll compressors on all 3-10 ton units except 3 ton standard efficiency
model (Reciprocating Compressor)
• Colored and numbered wiring
• Provisions for through the Base Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• 2" throwaway filters provided on 6-10 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22 or R-410A
• IAQ Sloped Drain Pans
• Single point power for Electric Heat
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
Featuring • 5 - year Limited Compressor Warranty
A New Look for a New Century • 1 - year Limited Parts Warranty
Beveled Top Added Flexibility
Smoother Design
Small compact cabinet • Electromechanical or ReliaTel™ controls (See page PC-35 for ReliaTel™
Recessed access handles Control Information)
• Standard or high efficiency cooling models available
• Convertible airflow (ships in downflow application)
• Fork lift openings on three sides of unit
• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options


• Through-the-Base — Electrical
• Convenience Outlet — Powered or unpowered
• Unit Disconnect Switch
• Smoke Detectors — Supply, return, or both
• Condenser Coil Coating
• Hinged Access Service Panels
• Discharge Air Sensor
• Fan Fail and Clogged Filter Switches
• Condenser Coil Guard — Hail Protection Quality
• TXV thermal expansion valve and split face evaporator coil
• Dehumidification Hot Gas Reheat Coil
• Novar Controls
• TCI (Trane Communication Interface)
• LonTalk (Communication Interface)
• 2" Pleated Media filters
• Phase Monitor

The same Trane Quality and


Reliability … with added Flexibility!

For complete equipment / combination


Effective 1/1/06 PC-24 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons

Table PC-25-A — Base Unit — Standard Efficiency — Electromechanical


Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max2
Tons 4
Ordering No.4 SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
TSC – 208-230/1/60 – Single Phase – No Heat
3 TSC036E1E0A0000 13.0 35,620 32 x 44 x 70 18 x 15.5 24 x 14 555 27.2 40
4 TSC048E1E0A0000 13.0 49,210 32 x 44 x 70 18 x 15.5 24 x 14 586 35.2 50
5 TSC060E1E0A0000 13.0 58,000 32 x 44 x 70 18 x 15.5 24 x 14 636 43.8 70
TSC – 208-230/3/60 – Three Phase – No Heat
3 TSC036A3E0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 17.9 25
4 TSC048A3E0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 23.9 35
5 TSC060A3E0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 31.5 50
3 TSC036E3E0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 21.4 30
4 TSC048E3E0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 25.2 35
5 TSC060E3E0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 29.5 45
6 TSC072A3E0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 32.7 50
71/2 TSC090A3E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 42.7 60
71/2 TSC092A3E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.9 50
81/2 TSC102A3E0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 45.1 60
10 TSC120A3E0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 52.6 60
TSC – 460/3/60 – Three Phase – No Heat
3 TSC036A4E0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 9.2 15
4 TSC048A4E0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 12.8 20
5 TSC060A4E0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 16.0 25
3 TSC036E4E0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 10.1 15
4 TSC048E4E0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 12.5 15
5 TSC060E4E0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 15.5 25
6 TSC072A4E0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 17.6 25
71/2 TSC090A4E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 22.6 35
71/2 TSC092A4E0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 20.5 25
81/2 TSC102A4E0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 24.0 30
10 TSC120A4E0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 26.9 35
TSC – 575/3/60 – Three Phase – No Heat
3 TSC036AWE0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 7.7 15
4 TSC048AWE0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 9.8 15
5 TSC060AWE0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 12.2 15
3 TSC036EWE0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 8.0 15
4 TSC048EWE0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 9.0 15
5 TSC060EWE0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 10.1 15
6 TSC072AWE0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 12.8 20
71/2 TSC090AWE0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 17.6 25
71/2 TSC092AWE0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 15.5 20
81/2 TSC102AWE0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 19.5 25
10 TSC120AWE0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 21.8 25
1 Upflow/Horizontal.
2 HACR breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7-A=R-22 or E=410A
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please PC-25 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons

Table PC-26-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor Controls


Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max2
Tons 4
Ordering No.4 SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
TSC – 208-230/1/60 – Single Phase – No Heat
3 TSC036E1R0A0000 13.0 35,620 32 x 44 x 70 18 x 15.5 24 x 14 555 27.2 40
4 TSC048E1R0A0000 13.0 49,210 32 x 44 x 70 18 x 15.5 24 x 14 586 35.2 50
5 TSC060E1R0A0000 13.0 58,000 32 x 44 x 70 18 x 15.5 24 x 14 636 43.8 70
TSC – 208-230/3/60 – Three Phase – No Heat
3 TSC036A3R0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 17.9 25
4 TSC048A3R0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 23.9 35
5 TSC060A3R0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 31.5 50
3 TSC036E3R0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 21.4 30
4 TSC048E3R0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 25.2 35
5 TSC060E3R0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 29.5 45
6 TSC072A3R0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 32.7 50
71/2 TSC090A3R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 42.7 60
71/2 TSC092A3R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.9 50
81/2 TSC102A3R0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 45.1 60
10 TSC120A3R0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 52.6 60
TSC – 460/3/60 – Three Phase – No Heat
3 TSC036A4R0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 9.2 15
4 TSC048A4R0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 12.8 20
5 TSC060A4R0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 16.0 25
3 TSC036E4R0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 10.1 15
4 TSC048E4R0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 12.5 15
5 TSC060E4R0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 15.5 25
6 TSC072A4R0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 17.6 25
71/2 TSC090A4R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 22.6 35
71/2 TSC092A4R0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 20.5 25
81/2 TSC102A4R0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 24.0 30
10 TSC120A4R0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 26.9 35
TSC – 575/3/60 – Three Phase – No Heat
3 TSC036AWR0A0000 10.7 37,400 32 x 44 x 70 18 x 15.5 24 x 14 501 7.7 15
4 TSC048AWR0A0000 10.0 49,200 32 x 44 x 70 18 x 15.5 24 x 14 526 9.8 15
5 TSC060AWR0A0000 10.2 63,100 32 x 44 x 70 18 x 15.5 24 x 14 543 12.2 15
3 TSC036EWR0A0000 13.0 37,150 32 x 44 x 70 18 x 15.5 24 x 14 555 8.0 15
4 TSC048EWR0A0000 13.0 49,450 32 x 44 x 70 18 x 15.5 24 x 14 586 9.0 15
5 TSC060EWR0A0000 13.0 62,270 32 x 44 x 70 18 x 15.5 24 x 14 636 10.1 15
6 TSC072AWR0A0000 10.3 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 824 12.8 20
71/2 TSC090AWR0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 897 17.6 25
71/2 TSC092AWR0A0000 10.3 90,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 899 15.5 20
81/2 TSC102AWR0A0000 10.3 105,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 978 19.5 25
10 TSC120AWR0A0000 10.4/10.31 117,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1052 21.8 25
1 Upflow/Horizontal.
2 HACR breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7-A=R-22 or E=410A
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 PC-26 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons

Table PC-27-A — Base Unit — High Efficiency — Electromechanical


Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max1
Tons Ordering No. SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
THC – 208-230/3/60 – Three Phase – No Heat
6 THC072A3E0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 34.8 50
71/2 THC092A3E0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.1 50
81/2 THC102A3E0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 42.3 50
10 THC120A3E0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 48.6 60
THC – 460/3/60 – Three Phase – No Heat
6 THC072A4E0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 17.5 25
71/2 THC092A4E0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 19.4 25
81/2 THC102A4E0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 21.4 25
10 THC120A4E0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 25.3 30
THC – 575/3/60 – Three Phase – No Heat
6 THC072AWE0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 13.5 20
71/2 THC092AWE0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 14.8 15
81/2 THC102AWE0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 16.6 20
10 THC120AWE0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 19.9 25
1 HACR breaker per NEC.
2 Downflow Airflow/Horizontal Airflow.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please PC-27 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons

Table PC-28-A — Base Unit — High Efficiency — ReliaTel™ Microprocessor Controls


Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max1
Tons Ordering No. SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
THC – 208-230/3/60 – Three Phase – No Heat
6 THC072A3R0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 34.8 50
71/2 THC092A3R0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 38.1 50
81/2 THC102A3R0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 42.3 50
10 THC120A3R0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 48.6 60
THC – 460/3/60 – Three Phase – No Heat
6 THC072A4R0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 17.5 25
71/2 THC092A4R0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 19.4 25
81/2 THC102A4R0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 21.4 25
10 THC120A4R0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 25.3 30
THC – 575/3/60 – Three Phase – No Heat
6 THC072AWR0A0000 11.5/11.32 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 861 13.5 20
71/2 THC092AWR0A0000 11.5/11.32 90,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 899 14.8 15
81/2 THC102AWR0A0000 11.5/11.32 102,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1036 16.6 20
10 THC120AWR0A0000 11.2/10.72 116,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1125 19.9 25
1 HACR breaker per NEC.
2 Downflow Airflow/Horizontal Airflow.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory productio

For complete equipment / combination


Effective 1/1/06 PC-28 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged
Cooling Convertible 3-10 Tons
(Model Digit Numbers)
Digit Description Order Number Digit Description Order Number
1-8 Main Assembly (see previous page) Circuit Breakerr ............................................................. 2
9 Unit Controls Phase Monitort ............................................................. 3
Electro-Mechanical ......................................................... E Phase Monitort & Non-Fused Disconnect Switch ............ 4
Unit Controls -ReliaTel™ Micro-processor ....................... R Phase Monitort & Circuit Breaker ................................... 5
10 (See Heater Table below) 20 Convenience Outlet
11 Minor Design Sequence No Convenience Outlet ................................................... 0
First Sequence .............................................................. A Unpowered Convenience Outlet ...................................... A
Powered Convenience Outlet (3 phase only)3 ................ B
12-13 Service Sequence
First Sequence (Factory Supplied) ................................. ✱,✱ 21 Communications Optionsy
No Communications Interface ......................................... 0
14 Fresh Air Selection Trane Communications Interface ..................................... 1
No Fresh Air ................................................................... 0 LonTalk® Communications Interface ................................. 2
0-50% Manual Outside Air Damperw .............................. A Novar 2024 Controls ....................................................... 3
0-50% Motorized Outside Air Damper .............................. B Novar 3051 Controls ....................................................... 4
0-100% Economizer, Dry Bulb without
Barometric Relief 2 .................................................... C 22 Refrigeration System Option
0-100% Economizer, Dry Bulb with Standard Refrigeration System ........................................ 0
Barometric Relief2 .................................................... D Thermal Expansion Valve (TXV) ...................................... A
0-100% Economizer, Reference Enthalpy Dehumidification (Hot Gas Reheat Coil)e ....................... B
without Barometric Relief12 ....................................... E 23 Refrigeration Controls
0-100%Economizer, Reference Enthalpy No Refrigeration Control .................................................. 0
with Barometric Relief12 ........................................... F High Pressure Control6y .............................................. 1
0-100%Economizer, Comparative Enthalpy Frostat5 ........................................................................ 2
without Barometric Relief 12 ..................................... G Crankcase Heater ........................................................... 3
0-100%Economizer, Comparative Enthalpy High Pressure Control6y and Frostat5 ......................... 4
with Barometric Relief 12 ......................................... H High Pressure Control6y and Crankcase Heater ............ 5
15 Supply Fan/Drive Type/Motor Frostat5 and Crankcase Heater6 .................................. 6
Standard Drive ............................................................... 0 High Pressure Control6y, Frostat5 and
Oversized Motor ............................................................. 1 Crankcase Heater6 ................................................... 7
Optional Belt Drive Motor (3 phase only) .......................... 2 24 Smoke Detector7y
16 Hinged Service Access & Filters No Smoke Detector ........................................................ 0
Standard Panels & Filters ................................................ 0 Return Air Smoke Detector 89 ...................................... A
Hinged Access Panels & Standard Filters ........................ A Supply Air Smoke Detector .............................................. B
Standard Panels & 2" Pleated Filters ............................... B Supply and Return Air Smoke Detectors 89 .................. C
Hinged Access Panels & 2" Pleated Filters ...................... C 25 Monitoring Controlsy
17 Condenser Coil Protection No Monitoring Control0 .................................................. 0
Standard Coil ................................................................. 0 Clogged Filter Switch0 ................................................... 1
Standard Coil with Hail Guard .......................................... 1 Fan Failure Switch0 ....................................................... 2
Epoxy Coated Condenser Coil ........................................ 2 Discharge Air Sensing Tube0 ......................................... 3
Epoxy Coated Condenser Coil with Hail Guard ................ 3 Clogged Filter Switch and Fan Fail Switch0 .................... 4
Clogged Filter Switch and Discharge
18 Through the Base Provisions Air Sensing Tube0 ...................................................... 5
No Through the Base Provisions ..................................... 0 Fan Fail Switch and Discharge Air Sensing Tube0 .......... 6
Through the Base Electricr ............................................ A Clogged Filter and Fan Fail Switches
19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only) and Discharge Air Sensing Tube0 ............................... 7
No Disconnect/ Circuit Breaker/No Phase Monitor ............ 0 Novar Return Air Sensorq .............................................. 8
Non-Fused Disconnectr ................................................ 1
1 Enthalpy control not available factory installed with electro-mechanical controls. order the return air smoke detectors when using this type of accessory.
2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without 9 Return Air Smoke Detector cannot be ordered with Novar Controls.
Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must be ordered 0 These options are standard when ordering Novar Controls.
as field installed accessory BAYBARM010A. q This options for use when ordering Novar Control only.
3 Requires use of Disconnect or Circuit Breaker. w The manual outside air damper will ship factory supplied within the unit, but must be field installed.
4 Standard refrigeration metering device - short orifice. e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.
5 Frostat cannot be field installed in electro-mechanical units. r Through the base electric required when ordering disconnect/circuit breaker options.
6 High Pressure control is standard on 3 phase units with scroll compressors and in TSC036A. t Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be an option.
7 Not available with BAYFRST001A High Temperature Stat accessory. y Not available with electro-mechanical unit controls.
8 The return air smoke detector may not fit up or work properly on the Convertible units when used in
conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not

Heaters (Digit 10)


kW Nominal No. kW Nominal No.
Rating Digit BTUH Stages Used With Rating Digit BTUH Stages Used With
208/240/1/60 460/3/60
3.7/5.0 (A) 12,800/17,100 1 T*C036-060A1 6.0 (B) 20,500 1 T*C036-060A4
7.5/10.0 (D) 25,600/34,100 2 T*C036-060A1 12.0 (E) 41,000 2 T*C036-060A4
10.3/13.8 (F) 35,300/47,100 2 T*C036-060A1 17.6 (G) 59,400 2 T*C036-060A4
13.2/17.6 (G) 45,100/60,100 2 T*C048-060A1 23.0 (J) 78,500 2 T*C060A4
208/240/3/60 9.0 (C) 30,700 1 T*C072-102A4
4.5/6.0 (B) 13,400/20,500 1 T*C036-060A3 18.0 (G) 61,400 1 T*C072-120A4
9.0/12.0 (E) 30,800/59,400 2 T*C036-060A3 27.0 (K) 92,100 2 T*C072-120A4
13.2/17.6 (G) 44,600/59,400 2 T*C036-060A3 36.0 (N) 122,900 2 T*C072-120A4
17.2/23.0 (J) 58,900/78,500 2 T*C060A3 54.0 (P) 184,300 2 T*C120A4
6.75/9.0 (C) 23,000/30,700 1 T*C072-102A3 575/3/60
13.5/18.0 (G) 46,100/61,400 1 T*C072-120A3 6.0 (B) 20,500 1 T*C036-060AW
20.3/27.0 (K) 69,000/92,100 2 T*C072-120A3 12.0 (E) 41,000 2 T*C036-060AW
27.0/36.0 (N) 92,200/122,900 2 T*C072-120A3 17.6 (G) 59,400 2 T*C036-060AW
40.5/54.0 (P) 138,200/184,300 2 T*C120A3 23.0 (J) 78,500 2 T*C060AW
9.0 (C) 30,700 1 T*C072-102AW
18.0 (G) 61,400 1 T*C072-120AW
27.0 (K) 92,100 2 T*C072-120AW
36.0 (N) 122,900 2 T*C072-120AW
54.0 (P) 184,300 2 T*C120AW
For complete equipment / combination
selections and installation instructions, please PC-29 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons

Table PC-30-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry
Model Power kW Nominal No.
Number Supply Rating BTUH Stages 1
Used With1
BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 T*C036-060(A or E)1
BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 T*C036-060(A or E)1
BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 T*C036-060(A or E)1
BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 T*C048-060(A or E)1
BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 T*C036-060(A or E)3
BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 T*C036-060(A or E)3
BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 T*C036-060(A or E)3
BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 T*C060(A or E)3
BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 T*C072A3,TSC090,092A3
BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 T*C072A3,TSC090,092A3
BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C072A3,TSC090,092A3
BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 T*C072A3,TSC090,092A3
BAYHTRT309A 208/240/3/60 6.75/9.0 23,000/30,700 1 THC092A3,T*C102A3
BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 THC092A3,T*C102,120A3
BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 T*C102,120A3,THC092A
BAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 THC092A3,T*C102,120A3
BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 T*C120A3

BAYHTRR406A 460/3/60 6.0 20,500 1 T*C036-060(A or E)4


BAYHTRR412A 460/3/60 12.0 41,000 2 T*C036-060(A or E)4
BAYHTRR418A 460/3/60 17.4 59,400 2 T*C036-060(A or E)4
BAYHTRR423A 460/3/60 23.0 78,500 2 T*C060(A or E)4
BAYHTRS409A 460/3/60 9.0 30,700 1 T*C072A4,TSC090,092A4
BAYHTRS418A 460/3/60 18.0 61,400 1 T*C072A4,TSC090,092A4
BAYHTRS427A 460/3/60 27.0 92,100 2 T*C072A4,TSC090,092A4
BAYHTRS436A 460/3/60 36.0 122,900 2 T*C072A4,TSC090,092A4
BAYHTRT409A 460/3/60 9.0 30,700 1 THC092A4,T*C102A4
BAYHTRT418A 460/3/60 18.0 61,400 1 THC092A4,T*C102,120A4
BAYHTRT427A 460/3/60 27.0 92,100 2 THC092A4,T*C102,120A4
BAYHTRT436A 460/3/60 36.0 122,900 2 THC092A4,T*C102-120A4
BAYHTRT454A 460/3/60 54.0 184,300 2 T*C120A4

BAYHTRRW06A 575/3/60 6.0 20,500 1 T*C036-060(A or E)W


BAYHTRRW12A 575/3/60 12.0 41,000 2 T*C036-060(A or E)W
BAYHTRRW18A 575/3/60 17.4 59,400 2 T*C036-060(A or E)W
BAYHTRRW23A 575/3/60 23.0 78,500 2 T*C060(A or E)W
BAYHTRSW09A 575/3/60 9.0 30,700 1 T*C072AW,TSC090,092AW
BAYHTRSW18A 575/3/60 18.0 61,400 1 T*C072AW,TSC090,092AW
BAYHTRSW27A 575/3/60 27.0 92,100 2 T*C072AW,TSC090,092AW
BAYHTRSW36A 575/3/60 36.0 122,900 2 T*C072AW,TSC090,092AW
BAYHTRTW18A 575/3/60 18.0 61,400 1 THC092AW,T*C102,120AW
BAYHTRTW27A 575/3/60 27.0 92,100 2 THC092AW,T*C102,120AW
BAYHTRTW36A 575/3/60 60 122,900 2 THC092AW,T*C102,120AW
BAYHTRTW54A 575/3/60 54.0 184,300 2 T*C120AW
1 A=R-22, E=410A.

For complete equipment / combination


Effective 1/1/06 PC-30 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons
Table PC-31-A — Accessories
Model Number Description u
Used Withu
BAYABRD001C .............. ReliaTel™ Options Module .................................................... See Note8
BAYASCT0010r* .......... Anti-Short-Cycle Timer .......................................................... T*C036-060(A or E)_E
BAYBARM010A6 ........... Barometric Relief ................................................................... T*C036-060(A or E)
BAYBARM011A6 ........... Barometric Relief ................................................................... T*C072-120A
BAYCCHT010B ............... Crankcase Heater .................................................................. THC072A3, TSC048-060(A or E)1,A3, T*C072-120A3
BAYCCHT011B ............... Crankcase Heater .................................................................. THC072A4,AW, TSC048-060(A or E)4,AW,T*C072-120A4,AW
BAYCCHT012A .............. Crankcase Heater .................................................................. T*C090A3
BAYCCHT013A .............. Crankcase Heater .................................................................. T*C090A4
BAYCCHT014A ............... Crankcase Heater .................................................................. T*C090AW
BAYCO2K001B5t ......... CO2 Sensor Kit, Wall Mounted ............................................... T*C036-060(A or E)_R, T*C072-120A_R w/Economizer
BAYCO2K003B5t ......... CO2 Sensor Kit, Duct Mounted .............................................. T*C036-060(A or E)_R, T*C072-120A_R w/Economizer
BAYCURB042A4 ........... Roof Curb .............................................................................. T*C036-060(A or E)
BAYCURB043A4 ........... Roof Curb .............................................................................. T*C072-120A
BAYDFPS003A58 ......... Clogged Filter Switch ............................................................. T*C036-060(A or E), T*C072-120A_R
BAYDFPS004A58 ......... Fan Failure Switch ................................................................. T*C036-060(A or E), T*C072-120A_R
BAYDMPR051A5 ........... 0-50% Motorized Outside Air Damper ................................... T*C036-060(A or E)_R
BAYDMPR052A0 ........... 0-50% Motorized Outside Air Damper ................................... T*C036-060(A or E)_E
BAYDMPR053By ........... 0-50% Manual Outside Air Damper ....................................... T*C036-060(A or E)
BAYDMPR054A5 ........... 0-50% Motorized Outside Air Damper ................................... T*C072-120A_R
BAYDMPR055A0 ........... 0-50% Motorized Outside Air Damper ................................... T*C072-120A_E
BAYDMPR056By ........... 0-50% Manual Outside Air Damper ....................................... T*C072-120A
BAYECON085A5 ........... 0-100% Dry Bulb Economizer without Barometric Relief ...... T*C036-060(A or E)_R
BAYECON086A0 ........... 0-100% Dry Bulb Economizer without Barometric Relief ...... T*C036-060(A or E)_E
BAYECON087A5 ........... 0-100% Dry Bulb Economizer without Barometric Relief ..... T*C072-120A_R
BAYECON088A0 ........... 0-100% Dry Bulb Economizer without Barometric Relief ..... T*C072-120A_E
BAYENTH005A15 ......... Reference Enthalpy Kit .......................................................... BAYECON085A, 087A
BAYENTH006A15 ......... Comparative Enthalpy Kit ...................................................... BAYECON085A, 087A
BAYENTH001A ............... Enthalpy Control (Solid State) ............................................... BAYECON0086A, 088A
BAYFRST001A50 ......... High Temperature Stat .......................................................... T*C036-060(A or E), T*C072-120A_R
BAYGARD036B .............. Condenser Coil Hail Guard .................................................... TSC036-060(A or E), THC036,048(A or E)
BAYGARD037B .............. Condenser Coil Hail Guard .................................................... THC060(A or E)
BAYGARD040B .............. Condenser Coil Hail Guard .................................................... THC072, 090
BAYGARD041B .............. Condenser Coil Hail Guard .................................................... TSC102,120A, THC092,102,120A
BAYHSDR012A .............. High Static Drive Kit ............................................................... T*C072A, TSC090,092A
BAYHSMT073A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)1,(A or E)3
BAYHSMT074A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)4
BAYHSMT075A .............. .45 HP Oversized motor kit .................................................... T*C036(A or E)W
BAYHSMT076A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)1,(A or E)3
BAYHSMT077A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)4
BAYHSMT078A .............. .75 HP Oversized motor kit .................................................... T*C048(A or E)W
BAYHSMT079A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)1,(A or E)3
BAYHSMT080A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)4
BAYHSMT081A .............. 1.2 HP Oversized motor kit .................................................... T*C060(A or E)W
BAYHSMT082A .............. 2 HP Oversized motor kit ....................................................... T*C072A3, A4
BAYHSMT083A .............. 2 HP Oversized motor kit ....................................................... T*C072AW
BAYHSMT084A .............. 3 HP Oversized motor kit ....................................................... T*C090, 092A3, A4
BAYHSMT085A .............. 3 HP Oversized motor kit ....................................................... T*C090, 092AW
BAYHSMT086A .............. 3 HP Oversized motor kit ....................................................... T*C102A3,A4, THC092A3,A4
BAYHSMT087A .............. 3 HP Oversized motor kit ....................................................... T*C102AW, THC092AW
BAYHSMT088A .............. 5 HP Oversized motor kit ....................................................... T*C120A3, A4
BAYHSMT089A .............. 5 HP Oversized motor kit ....................................................... T*C120AW
BAYICSI003A5e ............ Trane Communications Interface (TCI) .................................. T*C036-060(A or E), T*C072-120A_R
BAYKSKT255A ............... Quick Start Kit ........................................................................ THC060A1, TSC048-060A1
BAYKSKT256A ............... Quick Start Kit ........................................................................ TSC036(A or E)1
BAYLOAM020B258 ..... Evaporator Defrost Control (Frostat) ...................................... T*C036-060(A or E), T*C072-120A_R
BAYLTCI002B5 .............. LonTalk® Communications Interface (LCI) ............................. T*C036-060(A or E), T*C072-120A_R
BAYPWRX026Aq ........... Power Exhaust ...................................................................... T*072-120A3
BAYPWRX027Aq ........... Power Exhaust ...................................................................... T*072-120A4
BAYPWRX028Aq ........... Power Exhaust ...................................................................... T*072-120AW
BAYQACB009A49 ........ Quick Adapt Roof Curb .......................................................... T*C036-060(A or E)
BAYQACB010A49 ........ Quick Adapt Roof Curb .......................................................... T*C036-060(A or E)
BAYQACB011A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120A
BAYQACB012A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120A
BAYQACB013A4w ........ Quick Adapt Roof Curb .......................................................... T*C072-120A
BAYSTAT0235 ............... Remote Potentiometer ........................................................... BAYECON085A, 087A
BAYSERV001A5 ............ Selective Resistance Service Tester ..................................... T*C036-060(A or E), T*C072-120A_R
BAYSENS016A5 ............ Temperature Sensor .............................................................. T*C036-060(A or E)_R
BAYTUBE005A358 ...... Discharge Air Sensing Kit ...................................................... T*C036-060(A or E)_R
BAYTUBE007A358 ....... Discharge Air Sensing Kit ...................................................... T*C072-120_R
BAYVNOR001B58t ..... Ventilation Override Kit w/ReliaTel™ options module ............ T*C036-060(A or E), T*C072-120A_R
1 Kits contain all necessary parts to achieve desired level of 7 Cannot be used in conjunction with factory installed 0 For use with electromechanical controlled units only.
enthalpy control. smoke detector. q Cannot be used in conjunction with Barometric Relief.
2 For ReliaTel™ microprocessor controlled units only. 8 BAYABRD001C is required when ordering field installed Order Economizer without Barometric Relief.
Must be factory installed for electromechanical controlled accessories Clogged Filter Switch (BAYDFPS003A), Fan w BAYQACB012A adapts Voyager BAYCURB025A to
units Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit accept Precedent 6-10 ton unit. BAYQACB013A adapts
3 Used for true discharge air sensing in both heating and (BAYTUBE004A) or Evaporator Defrost Control (Frostat) Voyager BAYCURB026A to accept Precedent 6-10 ton
cooling.Required for supply air tempering. (BAYLOAM020B) Ventilation Override Kit unit. BAYQACB011A adapts Voyager BAYCURB022 to
4 Lynn Haven Manufacturing has a No-Return policy for this (BAYVNOR001B) unless the following options are factory accept Precedent 6-10 ton unit.
roof curb. installed: Frostat, Smoke Detector, Clogged Filter Switch, e Interface allows a unit with ReliaTel™ Controls to
5 For use with ReliaTel™ controlled units only Fan Failure Switch, Discharge Air Sensing Kit. These communicate with Tracer 100, Tracker, VariTrac II, and is
6 Barometric Relief accessory installs in ductwork for horizontal factory installed options include the ReliaTel™ Options the preferred method of communication to Tracer Summit.
configuration. For downflow configuration, installs in the unit's Module. r Activated on Power On.
horizontal return duct. See Installer's Guide for complete 9 BAYQACB009A adapts Voyager BAYCURB021B to t Field installed accessory requires economizer.
instructions. accept Precedent 3-5 ton unit. BAYQACB010A adapts y The manual outside air damper will ship factory supplied
Voyager BAYCURB022B to accept Precedent unit. within the unit, but must be field installed.
u A=R-22, E=410A.
For complete equipment / combination * Either Standard or High Efficiency.
selections and installation instructions, please PC-31 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-10 Tons

Table PC-32-A — Zone Sensors for ReliaTel™ Controlled Units


Model
Number Description Used With
BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019C
BAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS006,008010B,013,014C,017B
BAYSENS006B Single Setpoint Manual Changeover T*C036-060_R
BAYSENS008B Dual Setpoint Manual or Auto Changeover T*C036-060_R
BAYSENS010B Dual Setpoint Man. or Auto Changeover with System
Function Lights T*C036-120_R
BAYSENS019C Programmable Night Setback w/System Function Lights T*C036-120_R
BAYSENS013C1 Room Sensor w/ Override and Cancel Buttons T*C036-120_R
BAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override and
Cancel Buttons T*C036-120_R
BAYSENS017B Remote Room Sensor BAYSENS006B,008B,010B, & 019C
BAYSENS032A8 Dual Thermistor Remote Zone Sensor T*C036-120A_R
BAYSENS035A8 Digital Display Zone Sensor T*C036-120A_R
BAYSENS036A7 Wall-Mounted Humidity Zone Sensor THC120A,3,4,WR
BAYSENS037A7 Duct-Mounted Humidity Zone Sensor THC120A,3,4,WR

Table PC-32-B — Thermostats


Model
Number Description Used With
BAY24X042 DPDT Fan and Electric Heat Relay BAYSTAT008,010
BAY28X1904 Locking Thermostat Cover for up to 4 units Room Thermostats
BAYSTAT040B2 Programmable Thermostat T*C036-120A
BAYBASE008A Subbase 1-Stage Heating/Cooling BAYSTAT040B
BAYBASE006A Subbase 2-Stage Heating/Cooling BAYSTAT040B
BAYSENS033A Remote Wall Sensor BAYSTAT040B
BAYSENS034A Remote Duct Sensor BAYSTAT040B
BAYSTAT0083 Manual 1-Stage Heating/Cooling T*C036-120A
BAYSTAT0103 Auto 2-Stage Heating/Cooling T*C036-120A
TCONT200AN11AA Electronic 1 Htg/1 Clg (Non Prog) T*C036-090A
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.
2 Requires use of BAYBASE006A or BAYBASE008A.
3 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat.
4 Do not use with programmable thermostats.
5 Specially designed for electric heat applications (instant on fan).
6 Use only with electromechanical unit controls.
7 For use with Dehumidification (Hot Gas Reheat) Coil Option.
8 For use with ReliaTel™ Controls only.
*Either standard or high efficiency models

For complete equipment / combination


Effective 1/1/06 PC-32 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Light Commercial Packaged Cooling
New Model Reference Chart

Table PC-33-A — Quick Reference


Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
TCD036C100B Micro-Proc TSC036*1R0A0000 TSC036*1R0A**000000000000
Electro-Mech TSC036*1E0A0000 TSC036*1E0A**000000000000
TCD036C300B Micro-Proc TSC036*3R0A0000 TSC036*3R0A**000000000000
Electro-Mech TSC036*3E0A0000 TSC036*3E0A**000000000000
TCD036C400B Micro-Proc TSC036*4R0A0000 TSC036*4R0A**000000000000
Electro-Mech TSC036*4E0A0000 TSC036*4E0A**000000000000
TCH048C100B TCD048C100B Micro-Proc TSC048*1R0A0000 TSC048*1R0A**000000000000
Electro-Mech TSC048*1E0A0000 TSC048*1E0A**000000000000
TCH048C300B TCD048C300B Micro-Proc TSC048*3R0A0000 TSC048*3R0A**000000000000
Electro-Mech TSC048*3E0A0000 TSC048*3E0A**000000000000
TCH048C400B TCD048C300B Micro-Proc TSC048*4R0A0000 TSC048*4R0A**000000000000
Electro-Mech TSC048*4E0A0000 TSC048*4E0A**000000000000
TCH048CW00B TCD048CW00B Micro-Proc TSC048*WR0A0000 TSC048*WR0A**000000000000
Electro-Mech TSC048*WE0A0000 TSC048*WE0A**000000000000
TCH060C100B TCD060C100B Micro-Proc TSC060*1R0A0000 TSC060*1R0A**000000000000
Electro-Mech TSC060*1E0A0000 TSC060*1E0A**000000000000
TCH060C300B TCD060C300B Micro-Proc TSC060*3R0A0000 TSC060*3R0A**000000000000
Electro-Mech TSC060*3E0A0000 TSC060*3E0A**000000000000
TCH060C400B TCD060C400B Micro-Proc TSC060*4R0A0000 TSC060*4R0A**000000000000
Electro-Mech TSC060*4E0A0000 TSC060*4E0A**000000000000
TCH060CW00B TCD060CW00B Micro-Proc TSC060*WR0A0000 TSC060*WR0A**000000000000
Electro-Mech TSC060*WE0A0000 TSC060*WE0A**000000000000
*Digit 7- A=R-22, E=410A.
NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.

For complete equipment / combination


selections and installation instructions, please PC-33 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Light Commercial Packaged Cooling
New Model Reference Chart

Table PC-34-A — Quick Reference


Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
TCH074C300B TCD074C300B Micro-Proc TSC072A3R0A0000 TSC072A3R0A**000000000000
Electro-Mech TSC072A3E0A0000 TSC072A3E0A**000000000000
TCH074C400B TCD074C400B Micro-Proc TSC072A4R0A0000 TSC072A4R0A**000000000000
Electro-Mech TSC072A4E0A0000 TSC072A4E0A**000000000000
W 575 Volt Micro-Proc TSC072AWR0A0000 TSC072AWR0A**000000000000
Electro-Mech TSC072AWE0A0000 TSC072AWE0A**000000000000
TCH075C300B TCD075C300B Micro-Proc THC072A3R0A0000 THC072A3R0A**000000000000
Electro-Mech THC072A3E0A0000 THC072A3E0A**000000000000
TCH075C400B TCD075C400B Micro-Proc THC072A4R0A0000 THC072A4R0A**000000000000
Electro-Mech THC072A4E0A0000 THC072A4E0A**000000000000
TCH075CW00B TCD075CW00B Micro-Proc THC072AWR0A0000 THC072AWR0A**000000000000
Electro-Mech THC072AWE0A0000 THC072AWE0A**000000000000
TCH090D300B TCD090D300B Micro-Proc TSC090A3R0A0000 TSC090A3R0A**000000000000
Electro-Mech TSC090A3E0A0000 TSC090A3E0A**000000000000
TCH090D400B TCD090D400B Micro-Proc TSC090A4R0A0000 TSC090A4R0A**000000000000
Electro-Mech TSC090A4E0A0000 TSC090A4E0A**000000000000
TCH090DW00B TCD090DW00B Micro-Proc TSC090AWR0A0000 TSC090AWR0A**000000000000
Electro-Mech TSC090AWE0A0000 TSC090AWE0A**000000000000
TCH091D300B TCD091D300B Micro-Proc THC090A3R0A**000000000000
Electro-Mech THC090A3E0A**000000000000
TCH091D400B TCD091D400B Micro-Proc THC090A4R0A**000000000000
Electro-Mech THC090A4E0A**000000000000
W 575 Volt Micro-Proc THC090AWR0A**000000000000
Electro-Mech THC090AWE0A**000000000000
TCH102C300A TCD102C300A Micro-Proc TSC102A3R0A0000 TSC102A3R0A**000000000000
Electro-Mech TSC102A3E0A0000 TSC102A3E0A**000000000000
TCH102C400A TCD102C400A Micro-Proc TSC102A4R0A0000 TSC102A4R0A**000000000000
Electro-Mech TSC102A4E0A0000 TSC102A4E0A**000000000000
TCH102CW00A TCD102CW00A Micro-Proc TSC102AWR0A0000 TSC102AWR0A**000000000000
Electro-Mech TSC102AWE0A0000 TSC102AWE0A**000000000000
TCH103C300A TCD103C300A Micro-Proc THC102A3R0A0000 THC102A3R0A**000000000000
Electro-Mech THC102A3E0A0000 THC102A3E0A**000000000000
TCH103C400A TCD103C400A Micro-Proc THC102A4R0A0000 THC102A4R0A**000000000000
Electro-Mech THC102A4E0A0000 THC102A4E0A**000000000000
TCH103CW00A TCD103CW00A Micro-Proc THC102AWR0A0000 THC102AWR0A**000000000000
Electro-Mech THC102AWE0A0000 THC102AWE0A**000000000000
TCH120C300A TCD120C300A Micro-Proc TSC120A3R0A0000 TSC120A3R0A**000000000000
Electro-Mech TSC120A3E0A0000 TSC120A3E0A**000000000000
TCH120C400A TCD120C400A Micro-Proc TSC120A4R0A0000 TSC120A4R0A**000000000000
Electro-Mech TSC120A4E0A0000 TSC120A4E0A**000000000000
TCH120CW00A TCD120CW00A Micro-Proc TSC120AWR0A0000 TSC120AWR0A**000000000000
Electro-Mech TSC120AWE0A0000 TSC120AWE0A**000000000000
TCH121C300A TCD121C300A Micro-Proc THC120A3R0A0000 THC120A3R0A**000000000000
Electro-Mech THC120A3E0A0000 THC120A3E0A**000000000000
TCH121C400A TCD121C400A Micro-Proc THC120A4R0A0000 THC120A4R0A**000000000000
Electro-Mech THC120A4E0A0000 THC120A4E0A**000000000000
TCH121CW00A TCD121CW00A Micro-Proc THC120AWR0A0000 THC120AWR0A**000000000000
Electro-Mech THC120AWE0A0000 THC120AWE0A**000000000000
NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.

For complete equipment / combination


Effective 1/1/06 PC-34 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
ReliaTel™ Controls for Precedent™,
Precedent™ 13 SEER and Voyager™
Packaged Unit Protection/Operation Timings and Features

Alternating Lead/Lag – Dual Compressor Models Only — Increased Reliability — Fewer components (moving electro-
During periods of part load operation, each compressor cycles mechanical parts), less likelihood of equipment down time or
alternately as circuit number one, equalizing compressor wear and run failure. Standard
time. Enabled by cutting the wire (BLUE) at (RTRM) junction number
J3-8. Standard Integral Electric Heat Staging1 — Stages electric heaters “OFF”
and “ON”, eliminating the use of outdated sequencers. Standard
Anti Short Cycle Timer (ASCT) Function — Provides a three (3)
minute minimum “ON” time and a three (3) minute minimum “OFF” time Intelligent Fallback1 — A built in Default Control provides adaptive
for compressors, enhances compressor reliability by ensuring proper oil operation, which allows the equipment to continue
return. Standard to operate, providing comfort in the event of certain component
failures. Also, allows emergency operation without a Zone Sensor
Built In Evaporator Defrost Control (EDC) Function — Module (ZSM). Standard
Provides low ambient cooling down to 0°F. Standard
Low Ambient Start Timer (LAST) Function — Bypasses low
Built In Fan Delay Relay (FDR) Function — Provides custom indoor pressure control when a compressor starts, eliminating nuisance
fan timing sequences for the different types of equipment, enhancing compressor lock outs. Standard
efficiency and reliability. Standard
Lower Installation Cost — Using a standard Zone Sensor Module
Built In Night Set Back and Unoccupied Functions1 — When using (ZSM), control voltage wiring may be run up to five (5) times further
a standard dual setpoint/auto change over Zone Sensor Module (ZSM), than any electromechanical system, with no increase in wire gauge.
this function is enabled by applying a short across terminal J6-11 and Example: Electromechanical System –
J6-12. Sets cooling setpoint up a minimum of 7°F, sets heating setpoint 30 feet maximum using 22 gauge wire. Micro Control System – 150
back a minimum of 7°F, forces outside air damper (if present) minimum feet using 22 gauge wire. Standard
position to zero, and forces fan operation to automatic. Accessory
(requires time clock accessory or field supplied/installed switch or On Board Diagnostics1 — Assist with equipment troubleshooting, if
contacts). a problem occurrence should take place. Standard

Built In “TEST” Mode — Aids in quick verification of system Remote Sensing1 — All standard Zone Sensor Modules
and control operation, exercises both hardware and software (ZSMs) have remote sensing capabilities, typically achieved by using
(no special tools required). Standard an expensive program-mable thermostat and remote sensor with
electromechanical equipment. Accessory (requires use of remote
Built In Unoccupied Mode1 — When using a standard single sensor).
setpoint/manual change over Zone Sensor Module (ZSM), this function
is enabled by applying a short across terminal J6-11 and J6-12. Forces Selectable Economizer Dry Bulb Change Over — Allows the
outside air damper (if present) minimum position to zero, forces fan capability of selecting the following dry bulb change over points:
operation to automatic. Accessory (requires time clock accessory or 63, 67, 70 or 73°F. Standard with economizer accessory.
field supplied/installed switch or contacts.) Space Temperature Averaging1 — All standard Zone Sensor
Direct Digital Control (DDC)1 — Proportional Integral (PI) control. Modules (ZSMs) have space temperature averaging capabilities,
Proportional – sets corrective action proportional to deviation typically achieved by using an expensive programmable thermostat
from setpoint. Integral – fine tunes the rate of corrective action and minimum of four (4) remote sensors with electromechanical
proportional to the error (results in superior space temperature control). equipment. Averaging with ReliaTel™ can be achieved with two
Standard (2) sensors.

Economizer Preferred Cooling1 — Provides fully integrated Supply Air Tempering1 — A built in feature, once enabled only
operation if required. Will not turn on a compressor with the economizer, through an ICS device, may also be enabled using a digital or
if the space is recovering adequately with the economizer alone (0.2°F/ programmable Zone Sensor Module. When in the HEAT mode
minute). Allows the equipment to be utilized in more varied applications. (and not actively heating), if supply air temperature drops 10°F below
Standard with economizer accessory. the heating setpoint, heat is turned on until supply air temperature
rises to a point 10°F above the heating setpoint. Provides temperate
Emergency Stop Terminals On Low Voltage Terminal Board air during the “OFF” cycle, and eliminates
(LTB-5 and LTB-6) — Provides a convenient point to disable the cold air dumping from supply ducts. Extremely effective when
equipment completely, and immediately. Still provides communication to introducing any quantity of fresh air. Standard when using a RTOM,
BAS. Standard ICS device, digital, or programmable Zone Sensor Module.
Heat Pump Smart Recovery and Smart Staging1 — Inhibits Time Delay Relay (TDR) Function — Provides an incremental
auxiliary heat operation if the space is recovering adequately staging delay between compressors, minimizes equipment current
(0.1°F/minute) with the heat pump alone, providing considerable inrush and consumption by keeping compressors from starting
savings in operating costs. Standard simultaneously. Standard
Heat Pump Soft Start — Provides a smooth transition into heating Low Pressure and High Pressure Compressor Lockout — 3 trips
after defrost, minimizing noise and compressor stress associated with will lockout control.
switch over. Standard

1 Denotes features lost from utilizing standard conventional stat.

For complete equipment / combination


selections and installation instructions, please PC-35 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Micro Control for Precedent™,
Precedent™ 13 SEER and Voyager™
Operation With A Thermostat

When the ReliaTel™ RTRM Thermostat Interface is used, equipment operation


differs significantly. The basic equipment protection features remain intact, and the
following features and benefits are lost:

• Direct Digital Control (DDC) – • Low ambient disabled economizer and


Proportional Integral (PI) control is second condensing fan cycling
lost, equipment is controlled by a capability.
thermostat or generic building • Space Temperature Averaging
automation system device. capabilities are lost, unless generic
• Intelligent Fall back is lost, if a failure control being applied can accomplish
occurs in the device controlling the this.
equipment, operation will cease. • Supply Air Tempering feature is lost,
• Installation is more costly, with the discharge air temperature may be cold
addition of a thermostat or generic when not actively heating if outdoor air
control, the control wiring size must be is being introduced through the
increased. equipment.
• Heat Pump Smart Recovery and • Built In Night Set Back and Unoccu-
Smart Staging is lost, Heat Pump pied functions are lost, unless generic
operation becomes more costly unless control being applied can accomplish
generic control being applied can this.
accomplish this. • Built In Unoccupied Mode is lost,
• Remote Sensing capabilities are lost, unless generic control being applied
unless generic control being applied can accomplish this.
can accomplish this. • Economizer Preferred Cooling Feature
is lost, all compressor operation is
locked out below 50°F.

For complete equipment / combination


Effective 1/1/06 PC-36 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ 3-5 ton 13 SEER R-22
Packaged Cooling

Standard Features:
• Trane built scroll compressors on all 3-5 ton units
• Colored and numbered wiring
• Provisions for through the Base Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Single point power for Electric Heat
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
• 5 - year Limited Compressor Warranty
• 1 - year Limited Parts Warranty
Featuring
A New Look for a New Century Added Flexibility
Beveled Top • Electromechanical or ReliaTel™ controls (See page PC-35 for ReliaTel™
Smoother Design Control Information)
Small compact cabinet • Convertible airflow (ships in downflow application)
Recessed access handles • Fork lift openings on three sides of unit
• Belt drive - standard or oversized motors
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options


• Through-the-Base — Electrical
• Convenience Outlet — Powered or unpowered
• Unit Disconnect Switch
• Smoke Detectors — Supply, return, or both
• Condenser Coil Coating
• Hinged Access Service Panels
• Discharge Air Sensor
• Fan Fail and Clogged Filter Switches
• Condenser Coil Guard — Hail Protection Quality
• TXV thermal expansion valve and split face evaporator coil standard
• Dehumidification Hot Gas Reheat Coil
• Novar Controls
• TCI (Trane Communication Interface)
• LonTalk (Communication Interface)
• 2" Pleated Media filters
• Phase Monitor

The same Trane Quality and


Reliability … with added Flexibility!

For complete equipment / combination


selections and installation instructions, please PC-37 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-5 Tons 13 SEER R-22

Table PC-38-A — Base Unit — 13 SEER High Efficiency — Electromechanical


Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max1
Tons Ordering No. SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
THC – 208-230/3/60 – Three Phase – No Heat
3 THC033A3E0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 30
4 THC043A3E0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 35
5 THC063A3E0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45
THC – 460/3/60 – Three Phase – No Heat
3 THC033A4E0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 15
4 THC043A4E0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 15
5 THC063A4E0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20
THC – 575/3/60 – Three Phase – No Heat
3 THC033AWE0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 15
4 THC043AWE0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 15
5 THC063AWE0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 15

Table PC-38-B — Base Unit — 13 SEER High Efficiency — ReliaTel™ Microprocessor Controls
Cooling Cabinet Shipping
Unit 3
Performance3 Capacity Dimensions (in.) Downflow Downflow Weight Max1
Tons Ordering No. SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
THC – 208-230/3/60 – Three Phase – No Heat
3 THC033A3R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 19.9 30
4 THC043A3R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 22.6 35
5 THC063A3R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 28.8 45
THC – 460/3/60 – Three Phase – No Heat
3 THC033A4R0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 10.4 15
4 THC043A4R0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 11.8 15
5 THC063A4R0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 14.3 20
THC – 575/3/60 – Three Phase – No Heat
3 THC033AWR0A0000 13.0 38,000 32 x 44 x 70 18 x 15.5 24 x 14 549 7.7 15
4 THC043AWR0A0000 13.0 49,800 32 x 44 x 70 18 x 15.5 24 x 14 591 8.5 15
5 THC063AWR0A0000 13.0 62,400 36 x 44 x 70 18 x 15.5 24 x 14 641 11.4 15
1 HACR breaker per NEC.
2 Downflow Airflow/Horizontal Airflow.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 PC-38 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged
Cooling Convertible 3-5 Tons
13 SEER R-22 (Model Digit Numbers)
Digit Description Order Number Digit Description Order Number
1-8 Main Assembly (see previous page) Phase Monitort ............................................................. 3
9 Unit Controls Phase Monitort & Non-Fused Disconnect Switch ............ 4
Electro-Mechanical ......................................................... E Phase Monitort & Circuit Breaker ................................... 5
Unit Controls -ReliaTel™ Micro-processor ....................... R 20 Convenience Outlet
10 (See Heater Table below) No Convenience Outlet ................................................... 0
11 Minor Design Sequence Unpowered Convenience Outlet ...................................... A
First Sequence .............................................................. A Powered Convenience Outlet (3 phase only)3 ................ B
12-13 Service Sequence 21 Communications Optionsy
First Sequence (Factory Supplied) ................................. ✱,✱ No Communications Interface ......................................... 0
Trane Communications Interface ..................................... 1
14 Fresh Air Selection LonTalk® Communications Interface ................................. 2
No Fresh Air ................................................................... 0 Novar 2024 Controls ....................................................... 3
0-50% Manual Outside Air Damperw .............................. A Novar 3051 Controls ....................................................... 4
0-50% Motorized Outside Air Damper .............................. B
0-100% Economizer, Dry Bulb without 22 Refrigeration System Option
Barometric Relief 2 .................................................... C Standard Refrigeration System with
0-100% Economizer, Dry Bulb with Thermal Expansion Valve .............................................. 0
Barometric Relief2 .................................................... D Dehumidification (Hot Gas Reheat Coil)e ........................ B
0-100% Economizer, Reference Enthalpy 23 Refrigeration Controls
without Barometric Relief12 ....................................... E No Refrigeration Control .................................................. 0
0-100%Economizer, Reference Enthalpy High Pressure Control6y .............................................. 1
with Barometric Relief12 ........................................... F Frostat5 ........................................................................ 2
0-100%Economizer, Comparative Enthalpy Crankcase Heater ........................................................... 3
without Barometric Relief 12 ..................................... G High Pressure Control6y and Frostat5 ......................... 4
0-100%Economizer, Comparative Enthalpy High Pressure Control6y and Crankcase Heater ............ 5
with Barometric Relief 12 ......................................... H Frostat5 and Crankcase Heater6 .................................. 6
15 Supply Fan/Drive Type/Motor High Pressure Control6y, Frostat5 and
Standard Drive ................................................................ 0 Crankcase Heater6 ................................................... 7
16 Hinged Service Access & Filters 24 Smoke Detector7y
Standard Panels & Filters ................................................ 0 No Smoke Detector ........................................................ 0
Hinged Access Panels & Standard Filters ........................ A Return Air Smoke Detector 89 ...................................... A
Standard Panels & 2" Pleated Filters ............................... B Supply Air Smoke Detector .............................................. B
Hinged Access Panels & 2" Pleated Filters ...................... C Supply and Return Air Smoke Detectors 89 .................. C
17 Condenser Coil Protection 25 Monitoring Controlsy
Standard Coil ................................................................. 0 No Monitoring Control0 .................................................. 0
Standard Coil with Hail Guard .......................................... 1 Clogged Filter Switch0 ................................................... 1
Epoxy Coated Condenser Coil ........................................ 2 Fan Failure Switch0 ....................................................... 2
Epoxy Coated Condenser Coil with Hail Guard ................ 3 Discharge Air Sensing Tube0 ......................................... 3
Clogged Filter Switch and Fan Fail Switch0 .................... 4
18 Through the Base Provisions Clogged Filter Switch and Discharge
No Through the Base Provisions ..................................... 0 Air Sensing Tube0 ...................................................... 5
Through the Base Electricr ............................................ A Fan Fail Switch and Discharge Air Sensing Tube0 .......... 6
19 Disconnect/Circuit Breaker /Phase Monitor (3 phase only) Clogged Filter and Fan Fail Switches
No Disconnect/ Circuit Breaker/No Phase Monitor ............ 0 and Discharge Air Sensing Tube0 ............................... 7
Non-Fused Disconnectr ................................................ 1 Novar Return Air Sensorq .............................................. 8
Circuit Breakerr ............................................................. 2

1 Enthalpy control not available factory installed with electro-mechanical controls. 9 Return Air Smoke Detector cannot be ordered with Novar Controls.
2 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without 0 These options are standard when ordering Novar Controls.
Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must q This options for use when ordering Novar Control only.
be ordered as field installed accessory BAYBARM010A. w Factory Supplied Field Installed.The manual outside air damper will ship factory supplied within the
3 Requires use of Disconnect or Circuit Breaker. unit, but must be field installed.
4 Standard refrigeration metering device - short orifice. e Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.
5 Frostat cannot be field installed in electro-mechanical units. r Through the base electric required when ordering Disconnect/Circuit Breaker options.
6 High Pressure control is standard on 3 phase units with scroll compressors. t Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will be
7 Not available with BAYFRST001A High Temperature Stat accessory. an option.
8 The return air smoke detector may not fit up or work properly on the Convertible units when used in y Not available with electro-mechanical unit controls.
conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power
exhaust. Do not order the return air smoke detectors when using this type of accessory.

Heaters (Digit 10)


kW Nominal No. kW Nominal No.
Rating Digit BTUH Stages Used With Rating Digit BTUH Stages Used With
208/240/3/60 460/3/60
4.5/6.0 (B) 13,400/20,500 1 THC033-063A3 6.0 (B) 20,500 1 THC033-063A4
9.0/12.0 (E) 30,800/59,400 2 THC033-063A3 12.0 (E) 41,000 2 THC033-063A4
13.2/17.6 (G) 44,600/59,400 2 THC033-063A3 17.6 (G) 59,400 2 THC033-063A4
17.2/23.0 (J) 58,900/78,500 2 THC063A3 23.0 (J) 78,500 2 THC063A4
575/3/60
6.0 (B) 20,500 1 THC033-063AW
12.0 (E) 41,000 2 THC033-063AW
17.6 (G) 59,400 2 THC033-063AW
23.0 (J) 78,500 2 THC063AW

For complete equipment / combination


selections and installation instructions, please PC-39 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-5 Tons 13 SEER R-22

Table PC-40-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry
Model Power kW Nominal No.
Number Supply Rating BTUH Stages Used With
BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 THC033-063A3
BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 THC033-063A3
BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 THC033-063A3
BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 THC063A3

BAYHTRR406A 460/3/60 6.0 20,500 1 THC033-063AA4


BAYHTRR412A 460/3/60 12.0 41,000 2 THC033-063A4
BAYHTRR418A 460/3/60 17.4 59,400 2 THC033-063A4
BAYHTRR423A 460/3/60 23.0 78,500 2 THC063A4

BAYHTRRW06A 575/3/60 6.0 20,500 1 THC033-063AW


BAYHTRRW12A 575/3/60 12.0 41,000 2 THC033-063AW
BAYHTRRW18A 575/3/60 17.4 59,400 2 THC033-063AW
BAYHTRRW23A 575/3/60 23.0 78,500 2 THC063AW

For complete equipment / combination


Effective 1/1/06 PC-40 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-5 Tons 13 SEER R-22
Table PC-41-A — Accessories
Model Number Description Used With
BAYABRD001C ..................... ReliaTel™ Options Module ..................................................... See Note8
BAYASCT0010r .................. Anti-Short-Cycle Timer ........................................................... THC033-063A_E
BAYBARM010A6 .................. Barometric Relief .................................................................... THC033-063A
BAYCCHT010B ..................... Crankcase Heater ................................................................... THC033-063A3
BAYCCHT011B ..................... Crankcase Heater ................................................................... THC033-063A4,AW
BAYCO2K001B5t ............... CO2 Sensor Kit, Wall Mounted ................................................ THC033-063A_R
BAYCO2K003B5t ............... CO2 Sensor Kit, Duct Mounted ............................................... THC033-063A_R
BAYCURB042A4 .................. Roof Curb ............................................................................... THC033-063A
BAYDFPS003A58 ............... Clogged Filter Switch .............................................................. THC033-063A_R
BAYDFPS004A58 ............... Fan Failure Switch .................................................................. THC033-063A_R
BAYDMPR051A5 .................. 0-50% Motorized Outside Air Damper .................................... THC033-063A_R
BAYDMPR052A0 .................. 0-50% Motorized Outside Air Damper .................................... THC033-063A_E
BAYDMPR053By .................. 0-50% Manual Outside Air Damper ........................................ THC033-063A
BAYECON085A5 .................. 0-100% Dry Bulb Economizer without Barometric Relief ...... THC033-063A_R
BAYECON086A0 .................. 0-100% Dry Bulb Economizer without Barometric Relief ...... THC033-063A_E
BAYENTH005A15 ............... Reference Enthalpy Kit ........................................................... BAYECON085A
BAYENTH006A15 ............... Comparative Enthalpy Kit ....................................................... BAYECON085A
BAYENTH001A ..................... Enthalpy Control (Solid State) ................................................ BAYECON0086A
BAYFRST001A50 ................ High Temperature Stat ........................................................... THC033-063A_R
BAYGARD036B ..................... Condenser Coil Hail Guard ..................................................... THC033-043A
BAYGARD037B ..................... Condenser Coil Hail Guard ..................................................... THC063A
BAYHSMT073A ..................... .45 HP Oversized motor kit ..................................................... THC033A3
BAYHSMT074A ..................... .45 HP Oversized motor kit ..................................................... THC033A4
BAYHSMT075A ..................... .45 HP Oversized motor kit ..................................................... THC033AW
BAYHSMT076A ..................... .75 HP Oversized motor kit ..................................................... THC043A3
BAYHSMT077A ..................... .75 HP Oversized motor kit ..................................................... THC043A4
BAYHSMT078A ..................... .75 HP Oversized motor kit ..................................................... THC043AW
BAYHSMT079A ..................... 1.2 HP Oversized motor kit ..................................................... THC063A3
BAYHSMT080A ..................... 1.2 HP Oversized motor kit ..................................................... THC063A4
BAYHSMT081A ..................... 1.2 HP Oversized motor kit ..................................................... THC063AW
BAYICSI003A5e .................. Trane Communications Interface (TCI) .................................. THC033-063A_R
BAYLOAM020B258 ............ Evaporator Defrost Control (Frostat) ...................................... THC033-063A_R
BAYLTCI002B5 .................... LonTalk® Communications Interface (LCI) ............................. THC033-063A_R
BAYQACB009A49 ............... Quick Adapt Roof Curb ........................................................... THC033-063A
BAYQACB010A49 ............... Quick Adapt Roof Curb ........................................................... THC033-063A
BAYSTAT0235 ..................... Remote Potentiometer ............................................................ BAYECON085A
BAYSERV001A5 .................. Selective Resistance Service Tester ...................................... THC033-063A_R
BAYSENS016A5 .................. Temperature Sensor ............................................................... THC033-063A_R
BAYTUBE005A358 ............ Discharge Air Sensing Kit ....................................................... THC033-063A_R
BAYVNOR001B58t ............ Ventilation Override Kit w/ReliaTel™ options module ............ THC033-063A_R
1 Kits contain all necessary parts to achieve desired 8 BAYABRD001C is required when ordering field q Cannot be used in conjunction with Barometric
level of enthalpy control. installed accessories Clogged Filter Switch Relief. Order Economizer without Barometric
2 For ReliaTel™ microprocessor controlled units (BAYDFPS003A), Fan Fail Switch Relief.
only. Must be factory installed for electromechani- (BAYDFPS004A), Discharge Air Sensing Kit w BAYQACB012A adapts Voyager BAYCURB025A
cal controlled units (BAYTUBE004A) or Evaporator Defrost Control to accept Precedent 6-10 ton unit.
3 Used for true discharge air sensing in both (Frostat) (BAYLOAM020B) Ventilation Override Kit BAYQACB013A adapts Voyager BAYCURB026A
heating and cooling.Required for supply air (BAYVNOR001B) unless the following options are to accept Precedent 6-10 ton unit.
tempering. factory installed: Frostat, Smoke Detector, BAYQACB011A adapts Voyager BAYCURB022 to
4 Lynn Haven Manufacturing has a No-Return Clogged Filter Switch, Fan Failure Switch, accept Precedent 6-10 ton unit.
policy for this roof curb. Discharge Air Sensing Kit. These factory installed e Interface allows a unit with ReliaTel™ Controls to
5 For use with ReliaTel™ controlled units only options include the ReliaTel™ Options Module. communicate with Tracer 100, Tracker, VariTrac II,
6 Barometric Relief accessory installs in ductwork 9 BAYQACB009A adapts Voyager BAYCURB021B and is the preferred method of communication to
for horizontal configuration. For downflow to accept Precedent 3-5 ton unit. BAYQACB010A Tracer Summit.
configuration, installs in the unit's horizontal return adapts Voyager BAYCURB022B to accept r Activated on Power On.
duct. See Installer's Guide for complete Precedent unit. t Field installed accessory requires economizer.
instructions. 0 For use with electromechanical controlled units y The manual outside air damper will ship factory
7 Cannot be used in conjunction with factory only. supplied within the unit, but must be field installed.
installed smoke detector.

For complete equipment / combination


selections and installation instructions, please PC-41 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Cooling
Convertible 3-5 Tons 13 SEER R-22

Table PC-42-A — Zone Sensors for ReliaTel™ Controlled Units


Model
Number Description Used With
BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019C
BAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS006,008010B,013,014C,017B
BAYSENS006B Single Setpoint Manual Changeover THC033-063A_R
BAYSENS008B Dual Setpoint Manual or Auto Changeover THC033-063A_R
BAYSENS010B Dual Setpoint Man. or Auto Changeover with System
Function Lights THC033-063A_R
BAYSENS019C3 Programmable Night Setback w/System Function Lights THC033-063A_R
BAYSENS013C1 Room Sensor w/ Override and Cancel Buttons THC033-063A_R
BAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override and
Cancel Buttons THC033-063A_R
BAYSENS017B Remote Room Sensor BAYSENS006B,008B,010B, & 019C
BAYSENS032A8 Dual Thermistor Remote Zone Sensor THC033-063A_R
BAYSENS035A8 Digital Display Zone Sensor THC033-063A_R
BAYSENS036A7 Wall-Mounted Humidity Zone Sensor THC033-063A,3,4,WR
BAYSENS037A7 Duct-Mounted Humidity Zone Sensor THC033-063A,3,4,WR

Table PC-42-B — Thermostats


Model
Number Description Used With
BAY24X042 DPDT Fan and Electric Heat Relay BAYSTAT008,010
BAY28X1904 Locking Thermostat Cover for up to 4 units Room Thermostats
BAYSTAT040B2 Programmable Thermostat THC033-063A
BAYBASE008A Subbase 1-Stage Heating/Cooling BAYSTAT040B
BAYBASE006A Subbase 2-Stage Heating/Cooling BAYSTAT040B
BAYSENS033A Remote Wall Sensor BAYSTAT040B
BAYSENS034A Remote Duct Sensor BAYSTAT040B
BAYSTAT0083 Manual 1-Stage Heating/Cooling THC033-063A
BAYSTAT0103 Auto 2-Stage Heating/Cooling THC033-063A
TCONT200AN11AA Electronic 1 Htg/1 Clg (Non Prog) THC033-063A
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.
2 Requires use of BAYBASE006A or BAYBASE008A.
3 Requires DPDT Fan and Electric Heat Relay BAY24x042 when using electric heat.
4 Do not use with programmable thermostats.
5 Specially designed for electric heat applications (instant on fan).
6 Use only with electromechanical unit controls.
7 For use with Dehumidification (Hot Gas Reheat) Coil Option.
8 For use with ReliaTel™ Controls only.
*Either standard or high efficiency models
For additional Controls Information:
See ReliaTel™ and Micro Control features on PC-35 and PC-36.

For complete equipment / combination


Effective 1/1/06 PC-42 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Cooling with ReliaTel™ Controls
12½ through 25 Tons
12½-25 Ton TCD — Downflow • Operating charge of R-22 • Colored and numbered wiring
• Meets ASHRAE 90.1-1999 • “Quick Access” on 12½ – 25 • Quick-adjust idler arm pulley. Adjust belt
• ReliaTel™ control features are listed on • Scroll compressors on all units tension, change belts, adjust airflow quickly
page PC-35 • IAQ sloped condensate drain pans (12½ – 25 tons)
• Built-in anti-short cycle, time-delay relay • Dedicated horizontal and downflow units • 5-year limited compressor warranty
and minimum on time controls • Single point power for electric heat (12½ – 17½ tons)
• 2" standard for 12½ – 25 ton units • Complete line of optional electric heaters • 1-year limited compressor warranty
• Liquid line drier • Internally enhanced coil tubing (20 and 25 tons)
• Built-in fork lift holes • Low ambient to 0°F standard • 1-year limited parts warranty

Table PC-43-A — TCD Downflow — Micro Control Unit


Unit Power Supply Performance Cooling Dimensions (in.) Shipping Max Fuse Size or55 Downflow
Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA* Max Circuit Breaker* Roofcurb

121/2 TCD150D300B 208-230/3/60 9.8 150,000 50 x 72 x 108 1687 63 80 BAYCURB026B


121/2 TCD151C300B 208-230/3/60 11.3 154,000 501/8 x 715/16 x 1075/16 1776 64 80 BAYCURB026B
15 TCD180B300H 208-230/3/60 9.9 182,000 50 x 72 x 108 1866 78 90 BAYCURB026B
15 TCD181C300C4 208-230/3/60 11.5 189,000 54 x 855/16 x 1225/16 2297 74 90 BAYCURB027B
171/2 TCD210C300E 208-230/3/60 9.8 210,000 50 x 72 x 108 2202 88 110 BAYCURB026B
171/2 TCD211C300C 208-230/3/60 11.0 220,000 54 x 855/16 x 1225/16 2372 91 110 BAYCURB027B
20 TCD240B300J 208-230/3/60 9.7 242,000 54 x 86 x 123 2772 100 125 BAYCURB027B
20 TCD241C300C 208-230/3/60 10.6 268,000 54 x 855/16 x 1225/16 2470 99 125 BAYCURB027B
25 TCD300B300H 208-230/3/60 9.7 290,000 54 x 855/16 x 1225/16 2365 118 150 BAYCURB027B
25 TCD301C300C 208-230/3/60 10.4 300,000 54 x 855/16 x 1225/16 2475 120 150 BAYCURB027B

121/2 TCD150D400B 460/3/60 9.8 150,000 50 x 72 x 108 1687 33 40 BAYCURB026B


121/2 TCD151C400B 460/3/60 11.3 154,000 501/8 x 715/16 x 1075/16 1776 31 40 BAYCURB026B
15 TCD180B400H 460/3/60 9.9 182,000 50 x 72 x 108 1866 39 50 BAYCURB026B
15 TCD181C400C4 460/3/60 11.5 189,000 54 x 855/16 x 1225/16 2292 36 50 BAYCURB027B
171/2 TCD210C400E 460/3/60 9.8 210,000 50 x 72 x 108 2202 44 50 BAYCURB026B
171/2 TCD211C400C 460/3/60 11.0 220,000 54 x 855/16 x 1225/16 2380 44 60 BAYCURB027B
20 TCD240B400J 460/3/60 9.7 242,000 54 x 86 x 123 2372 50 60 BAYCURB027B
20 TCD241C400C 460/3/60 10.6 268,000 54 x 855/16 x 1225/16 2470 50 60 BAYCURB027B
25 TCD300B400H 460/3/60 9.7 290,000 54 x 855/16 x 1225/16 2365 58 70 BAYCURB027B
25 TCD301C400C 460/3/60 10.4 300,000 54 x 855/16 x 1225/16 2475 58 70 BAYCURB027B

121/2 TCD150DW00B 575/3/60 9.8 150,000 50 x 72 x 108 1687 26 30 BAYCURB026B


121/2 TCD151CW00B 575/3/60 11.3 154,000 501/8 x 715/16 x 1075/16 1776 25 30 BAYCURB026B
15 TCD180BW00H 575/3/60 9.9 182,000 50 x 72 x 108 1866 31 40 BAYCURB026B
15 TCD181CW00C4 575/3/60 11.5 189,000 54 x 855/16 x 1225/16 2297 29 40 BAYCURB027B
171/2 TCD210CW00E 575/3/60 9.8 210,000 50 x 72 x 108 2702 35 45 BAYCURB026B
171/2 TCD211CW00C 575/3/60 11.0 220,000 54 x 855/16 x 1225/16 2380 35 45 BAYCURB027B
20 TCD240BW00J 575/3/60 9.7 242,000 54 x 86 x 123 2372 40 45 BAYCURB027B
20 TCD241CW00C 575/3/60 10.6 268,000 54 x 855/16 x 1225/16 2470 40 50 BAYCURB027B
25 TCD300BW00H 575/3/60 9.7 290,000 54 x 855/16 x 1225/16 2365 46 50 BAYCURB027B
25 TCD301CW00C 575/3/60 10.4 300,000 54 x 855/16 x 1225/16 2475 47 60 BAYCURB027B
Supply Return Curb Size Roof Opening
Model No. 12
Downflow W x L12 12
Downflow W x L12 H x W x L1313 12
W x L12
TC❋150, 151, 180, 210 289/16 x 551/2 207/8 x 63 141/16 x 6615/16 x 1021/4 621/2 x 731/2
TC❋181, 211-301 289/16 x 691/2 221/4 x 77 141/16 x 8015/16 x 1171/8 761/2 x 81
MCA = Minimum Circuit Ampacity.
Maximum Fuse = Maximum Fuse Size or Maximum HACR Type Circuit Breaker Size.
1 Dimensions are in inches. See Outline Dimensions.
2 Interior Dimension.
3 Measurement Includes Curb Flange.
4 Uses 17½ – 25 ton dimensions.
5 HACR type circuit breaker per NEC.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please PC-43 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Cooling with ReliaTel™ Controls
12½ through 25 Tons
12½-25 Ton TCH — Horizontal • Operating charge of R-22 • Colored and numbered wiring
• Meets ASHRAE 90.1-1999 • “Quick Access” on 12½ – 25 • Quick-adjust idler arm pulley. Adjust belt
• Reliatel™ control features are listed on • Scroll compressors on all units tension, change belts, adjust airflow quickly
page PC-35 • IAQ sloped drain pans (12½ – 25 tons)
• Built-in anti-short cycle, time-delay relay • Dedicated horizontal and downflow units • 5-year limited compressor warranty
and minimum on time controls • Single point power for electric heat (12½ – 17½ tons)
• 2" filters for 12½ – 25 ton units • Complete line of optional electric heaters • 1-year limited compressor warranty
• Liquid line drier • Internally enhanced coil tubing (20 and 25 tons)
• Built-in fork lift holes • Low ambient to 0°F standard • 1-year limited parts warranty
Table PC-44-A — TCH Horizontal — Micro Control Unit
Unit Power Supply Performance Cooling Dimensions (in.) Shipping Max Fuse Size or44
Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) H x W x L Weight (Ibs.) MCA* Max Circuit Breaker*

121/2 TCH150D300B 208-230/3/60 9.8 150,000 50 x 72 x 108 1687 63 80


121/2 TCH151C300C 208-230/3/60 11.3 154,000 50 x 72 x 108 1776 64 80
15 TCH180B300H 208-230/3/60 9.9 182,000 50 x 72 x 108 1866 78 90
15 TCH181C300C3 208-230/3/60 11.5 189,000 54 x 86 x 123 2297 74 100
171/2 TCH210C300E 208-230/3/60 9.8 210,000 50 x 72 x 108 2202 88 100
171/2 TCH211C300C 208-230/3/60 11.0 220,000 54 x 86 x 123 2380 91 110
20 TCH240B300J 208-230/3/60 9.7 242,000 54 x 86 x 123 2372 100 125
20 TCH241C300C 208-230/3/60 10.6 268,000 54 x 86 x 123 2470 99 125
25 TCH300B300H 208-230/3/60 9.7 290,000 54 x 86 x 123 2365 118 150
25 TCH301C300C 208-230/3/60 10.4 300,000 54 x 86 x 123 2475 120 150

121/2 TCH150D400B 460/3/60 9.8 150,000 50 x 72 x 108 1687 33 40


121/2 TCH151C400C 460/3/60 11.3 154,000 50 x 72 x 108 1776 31 40
15 TCH180B400H 460/3/60 9.9 182,000 50 x 72 x 108 1866 39 50
15 TCH181C400C3 460/3/60 11.5 189,000 54 x 86 x 123 2292 36 50
171/2 TCH210C400E 460/3/60 9.8 210,000 50 x 72 x 108 2202 44 50
171/2 TCH211C400C 460/3/60 11.0 220,000 54 x 86 x 123 2380 44 60
20 TCH240B400J 460/3/60 9.7 242,000 54 x 86 x 123 2372 50 60
20 TCH241C400C 460/3/60 10.6 268,000 54 x 86 x 123 2470 50 60
25 TCH300B400H 460/3/60 9.7 290,000 54 x 86 x 123 2365 58 70
25 TCH301C400C 460/3/60 10.4 300,000 54 x 86 x 123 2475 58 70

121/2 TCH150DW00B 575/3/60 9.8 150,000 50 x 72 x 108 1687 26 30


121/2 TCH151CW00C 575/3/60 11.3 154,000 50 x 72 x 108 1776 25 30
15 TCH180BW00H 575/3/60 9.9 182,000 50 x 72 x 108 1866 31 40
15 TCH181CW00C3 575/3/60 11.5 189,000 54 x 86 x 123 2297 29 40
171/2 TCH210CW00E 575/3/60 9.8 210,000 50 x 72 x 108 2202 35 45
171/2 TCH211CW00C 575/3/60 11.0 220,000 54 x 86 x 123 2380 35 45
20 TCH240BW00J 575/3/60 9.7 242,000 54 x 86 x 123 2372 40 45
20 TCH241CW00C 575/3/60 10.6 268,000 54 x 86 x 123 2470 40 50
25 TCH300BW00H 575/3/60 9.7 290,000 54 x 86 x 123 2365 46 50
25 TCH301CW00C 575/3/60 10.4 300,000 54 x 86 x 123 2475 47 60
Supply Return
Model No. 12
Horizontal H x W12 12
Horizontal H x W12
TC❋ 150,151, 180, 210 421/2 x 261/2 421/2 x 249/16
TC❋181, 211-301 467/16 x 261/2 467/16 x 279/16
MCA = Minimum Circuit Ampacity.
Maximum Fuse = Maximum Fuse Size or Maximum HACR Type Circuit Breaker Size.
1 Dimensions are in inches. See Outline Dimensions.
2 Interior Dimension.
3 Uses 17½ – 25 ton dimensions.
4 HACR type circuit breaker per NEC.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 PC-44 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Cooling with ReliaTel™ Controls
12½ through 25 Tons
12 For Complete list of all Factory Installed Options, please refer to the FIOPS
Table PC-45-A — Factory Installed Accessories12
section of this book.
Digit Description Order Number Used With
1-9 Main Assembly (see previous page)
10 Factory Installed Options
No Options 0 TC*150-301
Downflow Economizer3 A TCD150-301
Oversized Motor B TC*150-241
Downflow Economizer and Oversized Motor3 C TCD150-241
Trane Communications Interface (TCI)4 F TC*150-301
Downflow Economizer TCI34 G TCD150-301
TXV/Face - Split Evaporator H TCD151, 181, 211, 241, 301
Oversized Motor and TXV/Face -Split Evaporator J TCD151, 181, 211, 241
Downflow Economizer, Oversized Motor and TXV/Face K TCD151, 181, 211, 241
Split Evaporator34
Downflow Economizer with TXV/Face - Split Evaportor3 L TCD151, 181, 211, 241, 301
Reheat Coil5 M TCD151, 181, 241
Downflow Economizer with Reheat Coil35 N TCD151, 181, 241
Oversized Motor and Reheat Coil5 P TCD151, 181, 241
Downflow Economizer, Oversized Motor and R TCD151, 181, 241
Reheat Coil 35
11-12 Minor Design and Service Sequence **
1 Price includes accessory and factory installation.
2 Four (4) week shipping approximately.
3 Some field set up required.
4 TCI is for use with non-VariTrac systems and VariTrac systems.
5 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel™ Options Module (FIYABRD002B), Frostat
(FIYLOAM023A), and 2" Pleated Filters (FIYPLTD001A, 002A, or 003A refer to FIOPS section for appropriate model number usage). For these or any Factory
Installed Options not included in 10th digit model number, digits 1-3 must be TFD.

Table PC-45-B — Zone Sensors


Model Number Description Used With
BAYSENS006B ......... Single Setpoint Manual Changeover ......................................................... TC*150-301
BAYSENS008B ......... Dual Setpoint Manual or Automatic Changeover ...................................... TC*150-301
BAYSENS010B ......... Dual Setpoint Manual or Automatic Changeover ...................................... TC*150-301
with System Function Lights
BAYSENS019C ........ Programmable Night Setback with System Function Lights ..................... TC*150-301
BAYSENS013C1 .... Room Sensor with Override Button ........................................................... TC*150-301
BAYSENS014C1 .... Room Sensor with Temperature Adjustment and Override ....................... TC*150-301
BAYSENS017B ......... Remote Room Sensor ............................................................................... BAYSENS006B, 008B,
010B and 019C
BAYSENS032Ay ..... Dual Thermistor Remote Zone Sensor ...................................................... TC*150-301
BAYSENS035Ay ..... Digital Display Zone Sensor ....................................................................... TC*150-301
BAYSENS036A ......... Wall-Mounted Humidity Sensor ................................................................. TFD151,181,241 (with Reheat)
BAYSENS037A ......... Duct-Mounted Humidity Sensor ................................................................ TFD151,181,241 (with Reheat)
BAYCLCK001Au ...... Electronic Time Clock for up to 4 units ...................................................... BAYSENS006B,008B, 010B
BAYMTPL003B ......... Retrofit Wall Cover Plate Kit (71/4" x 6") ..................................................... BAYSENS019C
BAYMTPL004A ........ Retrofit Wall Cover Plate Kit (43/4" x 43/4") ................................................. BAYSENS006B, 008B, 010B, 017B
and 013, 014C
For additional Controls Information:
See ReliaTel™ and Micro Control features on PC-35 and PC-36.

For complete equipment / combination


selections and installation instructions, please PC-45 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged Cooling
with ReliaTel™ Controls
12½ through 25 Tons Accessories
Table PC-46-A — Field Installed Accessories
For complete list of of All Factory Installed Options refer to FIOPS section of this book.
Model Number Description Used With
BAYABRD002e .......... ReliaTel™ Options Module ........................................................ TCD/TCH150-301
BAYCO2K002Brt ..... CO2 Sensor Wall Mounted ......................................................... TC*150-301 w/Economizer
BAYCO2K004Brt ..... CO2 Sensor Duct Mounted ........................................................ TC*150-301 w/Economizer
BAYCURB026B67 .... Downflow Roof Curb (Can not be adapted for horizontal use) ..... TCD150D,151C, 180B, 210C
BAYCURB027B67 .... Downflow Roof Curb (Can not be adapted for horizontal use) ..... TCD181C, 211C, 240B, 241C, 300B, 301C
BAYDFPS005Awe ..... Clogged Filter Switch ................................................................ TCD/TCH (12½-25 Tons)
BAYDFPS006Awe ..... Fan Failure Switch .................................................................... All Economizers and 0-50% Motorized Air Dampers
BAYDMPR029C .......... 0-25% Manual Outside Air Damper ........................................... TCD/TCH (12½-25 Tons)
BAYDMPR057A .......... 0-50% Motorized Outside Air Damper ........................................ TCD/TCH150D, 151C, 180B, 210C
BAYDMPR058A .......... 0-50% Motorized Outside Air Damper ........................................ TCD/TCH181C, 211C, 240B, 241C, 300B, 301C
BAYECON089Ae ....... Downflow Economizer with Barometric Relief ............................. TCD150D, 151C, 180B, 210C
BAYECON090Ae ....... Downflow Economizer with Barometric Relief ............................. TCD181C211C, 240B, 241C, 300B, 301C
BAYECON091A .......... Horizontal Economizer .............................................................. TCH151C, 180B, 210C
BAYECON092A .......... Horizontal Economizer .............................................................. TCH181C211C, 240B, 241C, 300B, 301C
BAYENTH007A12 ..... Reference Enthalpy Kit .............................................................. All BAYECNO089-92A
BAYENTH008A123 .. Comparative Enthalpy Kit .......................................................... All BAYECNO089-92A
BAYFRST003A0 ........ High Temperature Stat .............................................................. TCD/TCH150D
BAYGARD043Be ....... Tool-less Hail Guard .................................................................. TC*150
BAYGARD044Be ....... Tool-less Hail Guard .................................................................. T*C151C, 180B, 210C
BAYGARD045Ae ....... Tool-less Hail Guard .................................................................. T*C181C, 211C, 241C, 301C, 240B
BAYGARD047Ae ....... Tool-less Hail Guard .................................................................. TC*300B
BAYHSDR002B4 ....... High Static Drive ....................................................................... TCD/TCH151C
BAYHSDR005B4 ....... High Static Drive ....................................................................... TCD/TCH180B, 211C, 241C,TCD/TCH150D
BAYHSDR010A4 ....... High Static Drive ....................................................................... TCD/TCH300B, 301C
BAYHSDR011A4 ....... High Static Drive ....................................................................... TCD/TCH181C
BAYHSMT039B4e .... 5HP Oversized Motor Kit ........................................................... TCD/TCH151C, 180B,150D
BAYHSMT040B4e .... 5HP Oversized Motor Kit (575V) ................................................ T*151CW, 180BW
BAYHSMT042A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*211C, 240B, 241CW
BAYHSMT055B4e .... 5HP Oversized Motor Kit ........................................................... TCD/TCH181C
BAYHSMT059A5e .... 7-1/2HP Oversized Motor Kit (230V) .......................................... TCD/TCH210C
BAYHSMT060A5e .... 7-1/2HP Oversized Motor Kit (460V) .......................................... TCD/TCH210C
BAYHSMT061A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*210CW
BAYHSMT072A4e .... 7-1/2HP Oversized Motor Kit (575V) .......................................... TC*181CW
BAYHSMT098A4e .... 7-1/2HP Oversized Motor Kit ..................................................... TC*211,240,241C3
BAYHSMT099A4e .... 7-1/2HP Oversized Motor Kit ..................................................... TC*211,240,241C4
BAYICSI004Bty ........ Comm 3/4 Trane Communications Interface (TCI) ...................... TC*150-301
BAYLOAM023Ae ........ Evaporator Defrost Control Frostat ............................................. TC*150-301
BAYLSDR004A5 ....... Low Static Drive ........................................................................ TCD/TCH210C
BAYLSDR002A5 ....... Low Static Drive ........................................................................ TCD/TCH300B, 301C
BAYLTCI003By .......... LonTalk® Communications Interface (LCI) .................................. TC*150-301
BAYPWRX029A .......... Power Exhaust for 230 volt units ................................................ BAYECON089-092A
BAYPWRX030A .......... Power Exhaust for 460 volt units ................................................ BAYECON089-092A
BAYPWRX031A .......... Power Exhaust for 575 volt units ................................................ TCD150DW
BAYSENS016A ........... Temperature Sensor ................................................................. TCD/TCH (12½-25 Tons)
BAYSERV001A ........... Selective Resistance Service Tester .......................................... TCD/TCH (12½-25 Tons)
BAYSTAT0238 ............ Remote Potentiometer .............................................................. All Economizers and 0-50% Motorized Air Dampers
BAYTUBE008A9we .. Discharge Air Sensing Kit .......................................................... TCD150D-301
BAYTUBE009A9we .. Discharge Air Sensing Kit .......................................................... TCH150D-301
BAYVNOR002Bw ...... Ventilation Override Kit ........................................................... TC*150-301 w/ReliaTel™ Options Module
1 Kit contains all necessary parts to achieve desired level of Enthalpy Control.
2 Reference Enthalpy senses outside temperature/humidity and inside supply air only.
3 Comparative Enthalpy senses outside temperature/humidity and inside supply and return air.
4 High static drive and oversized motors are mutually exclusive, Do Not Combine.
5 Low static drive and oversized motors are mutually exclusive, Do Not Combine.
6 Clarksville manufacturing has a no return policy for this roof curb.
7 For downflow use only. Can not be adapted for horizontal units.
8 Cannot be used with Integrated Comfort™ Systems.
9 Used for true discharge air sensing in both heating and cooling models.
0 Must be used with either field or factory installed TCI (Trane Communications Interface).
q Cannot be used with economizer and motorized outside air damper. For operational characteristics see Accessory IOM.
w BAYABRD002B is required when ordering field installed BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A or BAYVNOR002B.
e Field or factory installed option.
r Field installed accessory. Requires an economizer.
t Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.
y With ReliaTel™ controlled units only.

For complete equipment / combination


Effective 1/1/06 PC-46 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Cooling with ReliaTel™ Controls
12½ through 25 Tons
Table PC-47-A — Downflow /Horizontal Supplementary Heaters:
Model Power kW Nominal No.
Number Supply Rating BTUH Stages Used With
AYDHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 TCD180B,181C,150D3,151C3
AYDHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCD180B,181C,150D3,151C3
AYDHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCD180B,181C,150D3,151C3

AYDHTRL418A 460/3/60 18.0 61,400 1 TCD150D, 180B4,181C4,151C4


AYDHTRK427A 460/3/60 27.0 92,150 2 TCD181C4
AYDHTRK436A 460/3/60 36.0 122,900 2 TCD150D, 180B4,181C4,151C4
AYDHTRK454A 460/3/60 54.0 184,300 2 TCD150D, 180B4,181C4,151C4

AYDHTRL336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCD210-301C3,B3


AYDHTRL354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCD210-301C3,B3
AYDHTRK372A 208/240/3/60 54.0/72.0 184,300/245,700 2 TCD211-301C3,B3

AYDHTRL427A 460/3/60 27.0 92,150 2 TCD211-301C4


AYDHTRL436A 460/3/60 36.0 122,900 2 TCD210-301C4,B4
AYDHTRL454A 460/3/60 54.0 184,300 2 TCD210-301C4,B4
AYDHTRK472A 460/3/60 72.0 245,700 2 TCD211-301C4,B4

AYHHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 TCH181C3


AYHHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH181C3
AYHHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH181C3

AYHHTRM418A 460/3/60 18.0 61,400 1 TCH181C4


AYHHTRK436A 460/3/60 36.0 122,900 2 TCH181C4
AYHHTRM454A 460/3/60 54.0 184,300 2 TCH181C4

AYHHTRN318A 208/240/3/60 13.5/18.0 46,000/61,400 1 TCH150D3,180B3,151C3


AYHHTRP336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH150D3,180B3,151C3
AYHHTRP354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH150D3,180B3,151C3

AYHHTRN418A 460/3/60 18.0 61,400 1 TCH150D, 180B4,151C4


AYHHTRP436A 460/3/60 36.0 122,900 2 TCH150D, 180B4,151C4
AYHHTRP454A 460/3/60 54.0 184,300 2 TCH150D, 180B4,151C4

AYHHTRQ336A 208/240/3/60 27.0/36.0 92,200/22,900 2 TCH210C3


AYHHTRQ354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH210C3

AYHHTRQ436A 460/3/60 36.0 122,900 2 TCH210C4


AYHHTRQ454A 460/3/60 54.0 184,300 2 TCH210C4

AYHHTRN336A 208/240/3/60 27.0/36.0 92,200/122,900 2 TCH211-301C3,B3


AYHHTRN354A 208/240/3/60 40.5/54.0 138,200/184,300 2 TCH211-301C3,B3
AYHHTRN372A 208/240/3/60 54.0/72.0 184,300/245,700 2 TCH211-301C3,B3

AYHHTRN436A 460/3/60 36.0 122,900 2 TCH211-301C4,B4


AYHHTRN454A 460/3/60 54.0 184,300 2 TCH211-301C4,B4
AYHHTRN472A 460/3/60 72.0 245,700 2 TCH211-301C4,B4
Note: Unit with heater is single circuit/single point.

For complete equipment / combination


selections and installation instructions, please PC-47 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged Cooling
with ReliaTel™ Controls
12½ through 25 Tons
Table PC-48-A — Downflow /Horizontal Supplementary Heaters:
Model Power kW Nominal No.
Number Supply Rating BTUH Stages Used With
AYDHTRKW18A 575/3/60 18.0 61,400 1 TCD150DW,180BW,151CW,181C
AYDHTRKW36A 575/3/60 36.0 122,900 2 TCD150DW,180BW,210CW,181C
240-300BW,211-301CW

AYDHTRLW54A 575/3/60 54.0 184,300 2 TCD210CW,240-300B,211-301CW


AYDHTRKW72A 575/3/60 72.0 245,700 2 TCD211-301CW

AYDHTRMW36A 575/3/60 36.0 122,900 2 TCD150DW,180BW,210CW


181C,240-300BW,211-301CW
AYDHTRMW72A 575/3/60 72.0 245,700 2 TCD240-300BW

AYHHTRMW18A 575/3/60 18.0 61,400 1 TCD181C


AYHHTRMW36A 575/3/60 36.0 122,900 2 TCH181CW,211-301CW
AYHHTRMW54A 575/3/60 54.0 184,300 2 TCH240-300BW,181C

AYHHTRNW18A 575/3/60 18.0 61,400 1 TCH150DW,180BW,151C,181C


AYHHTRNW54A 575/3/60 54.0 184,300 2 TCH240-300BW,211-301CW
AYHHTRNW72A 575/3/60 72.0 245,700 2 TCH240-300BW,211-301CW

AYHHTRPW36A 575/3/60 36.0 122,900 2 TCH150DW,180BW,210CW,151C


AYHHTRPW54A 575/3/60 54.0 184,300 2 TCH150DW,180BW,151C

AYHHTRQW54A 575/3/60 54.0 184,300 2 TCH210CW


AYHHTRKW72A 575/3/60 72.0 245,700 2 TCH211-301CW
Note: Unit with heater is single circuit/single point.
See ReliaTel™ and Micro Control features on PC-35 and PC-36.

For complete equipment / combination


Effective 1/1/06 PC-48 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

• Weater Beater top contoured and reinforced • Solenoid operated switchover valve
for strength. • Copper tube, aluminum plate fin Indoor coil
• Exclusive Climatuff® high efficiency • Expansion valve no bleed on outdoor coil
compressor • High efficiency outdoor fan motor with
• Aerospace Ducted Outdoor fan for quiet polarized plug
operation • Expansion valve no bleed on indoor coil
• Composite Vortica® Blower uses less • Water shed base
energy to provide more air with less sound. • UL Listed
• Side electrical service access for high and • Crankcase heater
low voltage • Direct drive blower 2-speed motor
• Sloped composite no-rust drain pan • Compressor internal overload protection
• Shipped for horizontal application, easily • Protected pressure taps for refrigerant
convertible to downflow checks
• One electric heater family • Standard operation to 55°F. as manufac-
• Optional filter rack fits inside unit tured
• Low voltage polarized plug for easy electric • Low ambient cooling to 0°F. with
heater installation BAYLOAM105A
• Heavy gauge steel cabinet with weather • 10-year limited compressor
• Architectual Louvers and Corner Guards for resistant, baked enamel finish warranty, 5-year other parts single phase
durable protection and extra safety. • Top discharge fan (Residential Use Only)
• Appliance Grade Finish durable powder paint • Demand defrost control • Optional extended warranties
baked on both sides of every panel. • Refrigerant line filter drier

Table PH-1-A — 2WCX - XL13c - Convertible Package Heat Pump - R-22


Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
2WCX – 208/230/1/60
2WCX3024A1000A 23,200 13.45/11.80 7.9 453 11.5 20 72 36 x 51 x 43
2WCX3030A1000A 29,400 13.05/11.00 8.4 454 17.1 25 72 36 x 51 x 43
2WCX3036A1000A 37,200 13.20/11.00 8.0 468 24.2 40 75 36 x 51 x 43
2WCX3042A1000A 40,000 13.10/11.20 8.25 529 24.6 40 73 38 x 61 x 46
2WCX3048A1000A 47,000 13.30/11.30 7.95 553 28.6 45 73 38 x 61 x 46
2WCX3060A1000A 58,500 13.35/11.25 8.3 623 40.4 60 72 42 x 61 x 46

Table PH-1-B — 4WCX - XL13c - Convertible Package Heat Pump - R-410A


Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
4WCX – 208/230/1/60
4WCX3018A1000A 18,600 13.15/11.10 7.7 444 10.6 15 69 36 x 51 x 43
4WCX3036A1000A 36,200 13.20/11.00 7.75 468 25.5 40 71 36 x 51 x 43
4WCX3048A1000A 46,000 13.15/10.75 8.25 553 31.1 50 73 38 x 61 x 46
4WCX3060A1000A 59,500 13.05/10.85 7.85 618 43.3 60 72 40 x 61 x 46
4WCX – 208/230/3/60
4WCX3036A3000A 36,200 13.20/11.00 7.75 468 18.2 30 71 36 x 51 x 43
4WCX3048A3000A 46,600 13.15/10.75 8.25 553 23.6 35 73 38 x 61 x 46
4WCX3060A3000A 59,500 13.05/10.85 7.85 618 31.5 50 72 40 x 59 x 44
4WCX– 460/3/60
4WCX3036A4000A 36,200 13.20/11.00 7.75 468 8.7 15 71 36 x 51 x 43
4WCX3048A4000A 46,000 13.15/10.75 8.25 553 11.7 15 73 38 x 61 x 46
4WCX3060A4000A 59,500 13.05/10.85 7.85 618 19.3 25 72 40 x 61 x 46

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PH-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCX3018A through 2/4WCX3036A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PH-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCX3018A through 2/4WCX3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCX3042A through 2/4WCX3060A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PH-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCX3042A through 2/4WCX3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

• Climatuff® high efficiency • High efficiency outdoor fan motor


compressor with polarized plug
• Shipped for horizontal application, easily • Expansion valve no bleed on indoor coil
convertible to downflow • Water shed base
• One electric heater family • UL Listed
• Optional filter rack fits inside unit • Crankcase heater
• Low voltage polarized plug for easy electric • Direct drive blower 2-speed motor
heater installation • Compressor internal overload protection
• Heavy gauge steel cabinet with weather • Protected pressure taps for
resistant, baked enamel finish refrigerant checks
• Top discharge fan • Standard operation to 55°F. as manufac-
• Demand defrost control tured
• Refrigerant line filter drier • Low ambient cooling to 0°F. with
• Solenoid operated switchover valve BAYLOAM105A
• Copper tube, aluminum plate fin Indoor coil • 5-year limited compressor
• Expansion valve no bleed on outdoor coil warranty, 5-year other parts single phase
(Residential Use Only)
• Optional extended warranties
Table PH-6-A — 2WCC - XB13c - Convertible Package Heat Pump - R-22
Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
2WCC– 208/230/1/60
2WCC3024A1000A 23,000 13.00/11.00 7.7 453 12.5 20 76 36 x 49 x 42
2WCC3030A1000A 28,000 13.00/11.00 7.7 454 17.1 25 76 36 x 49 x 42
2WCC3036A1000A 35,000 13.00/11.00 7.7 468 24.2 40 75 36 x 49 x 42
2WCC3042A1000A 40,000 13.00/11.00 7.7 529 24.6 40 78 38 x 59 x 44
2WCC3048A1000A 45,500 13.00/11.00 7.7 553 28.6 45 79 38 x 59 x 44
2WCC3060A1000A 58,000 13.00/11.00 7.7 623 40.4 60 79 42 x 59 x 44

Table PH-6-B — 4WCC - XB13c - Convertible Package Heat Pump - R-410A


Cabinet
Model Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
4WCC– 208/230/1/60
4WCC3018A1000A 18,000 13.00/11.00 7.7 444 10.6 15 74 36 x 49 x 42
4WCC3036A1000A 35,000 13.00/11.00 7.7 468 25.5 40 75 36 x 49 x 42
4WCC3048A1000A 45,500 13.00/10.75 7.7 553 31.1 50 80 38 x 59 x 44
4WCC3060A1000A 58,000 13.00/10.85 7.7 618 43.3 60 79 40 x 59 x 44
4WCC – 208/230/3/60
4WCC3036A3000A 35,000 13.00/11.00 7.7 468 18.2 30 75 36 x 49 x 42
4WCC3048A3000A 45,500 13.00/10.75 7.7 553 23.6 35 80 38 x 59 x 44
4WCC3060A3000A 58,000 13.00/10.85 7.7 618 31.5 50 79 40 x 59 x 44
4WCC– 460/3/60
4WCC3036A4000A 35,000 13.00/11.00 7.7 468 8.7 15 75 36 x 49 x 42
4WCC3048A4000A 45,500 13.00/10.75 7.7 553 11.7 15 80 38 x 59 x 44
4WCC3060A4000A 58,000 13.00/10.85 7.7 618 19.3 25 79 40 x 59 x 44

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PH-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCC3018A through 2/4WCC3036A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PH-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCC3018A through 2/4WCC3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PH-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCC3042A through 2/4WCC3060A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2/4WCC3042A through 2/4WCC3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PH-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

2WCX 4WCX 2WCC 4WCC


Table PH-11-A — Accessories 2-5 1½-5 2-5 1½-5
BAYADAP050A ............... Adapter Curb (Cabinet A/B) .......................................................................... 1½-3 1½-3 1½-3 1½-3
BAYADAP051A ............... Adapter Curb (Cabinet C) ............................................................................. 1½-3 1½-3 1½-3 1½-3
BAYADAP052A ............... Adapter Curb (Cabinet A/B) .......................................................................... 3½-5 3½-5 3½-5 3½-5
BAYADAP053A ............... Adapter Curb (Cabinet C) ............................................................................. 3½-5 3½-5 3½-5 3½-5
BAYADAP054A ............... Adapter Curb (Cabinet D) ............................................................................. 3½-5 3½-5 3½-5 3½-5
BAYCCHT101A .............. Crankcase Heater (230V) ............................................................................. 2-2½,5 1½ 2-2½,4 1½
BAYCCHT102A .............. Crankcase Heater (230V) ............................................................................. 3-3½ 3, 4 3-3½ 3,4
BAYCCHT104A .............. Crankcase Heater (460V) ............................................................................. — 5 — 5
BAYCOVR112A .............. 12" Duct Shroud (Covers Horizontal Ducts)w ................................................ 3½-5 3½-5 3½-5 3½-5
BAYCOVR118A .............. 18" Duct Shroud (Covers Horizontal Ducts)w ................................................ 3½-5 3½-5 3½-5 3½-5
BAYCURB050A .............. Flat Roof Curb (Insulated)3 .......................................................................... 1½-3 1½-3 1½-3 1½-3
BAYCURB051A .............. Flat Roof Curb (Insulated)3 .......................................................................... 3½-5 3½-5 3½-5 3½-5
BAYDMPR101A .............. 2-Position Motorized Damper ........................................................................ 1½-3 1½-3 1½-3 1½-3
BAYDMPR102A .............. 2-Position Motorized Damper ........................................................................ 3½-4 3½-4 3½-4 3½-4
BAYECON101A .............. Economizer with Barometric Relief12458 .................................................. 1½-3 1½-3 1½-3 1½-3
BAYECON102A .............. Economizer with Barometric Relief12458 .................................................. 3½-4 3½-4 3½-4 3½-4
BAYECON200A .............. Economizer (Horizontal)1248 ..................................................................... ✔ ✔ ✔ ✔
BAYECON201A .............. Economizer (Horizontal)1248 ..................................................................... 3½-5 3½-5 3½-5 3½-5
BAYENTH100A .............. Enthalpy Control Kit4 .................................................................................... ✔ ✔ ✔ ✔
BAYEXMK001A .............. Extreme Conditions Mounting Kit .................................................................. ✔ ✔ ✔ ✔
BAYEXMK002A .............. Extreme Conditions Mounting Kit .................................................................. ✔ ✔ ✔ ✔
BAYEXMK003A .............. Extreme Conditions Mounting Kit (Used on Slab Mounts) ............................. ✔ ✔ ✔ ✔
BAYFLTR101A ................ 1-2" Filter Frame2 ......................................................................................... 1½-3 1½-3 1½-3 1½-3
BAYFLTR201A ................ 1-2" Filter Frame2 ......................................................................................... 3½-4 3½-4 3½-4 3½-4
BAYLIFT002B ................. Lifting Lug Kit ............................................................................................... ✔ ✔ ✔ ✔
BAYLOAM011A .............. Evaporator Defrost Control Kit ....................................................................... ✔ ✔ ✔ ✔
BAYLOAM105A .............. Low Ambient Control Kitq ............................................................................. ✔ ✔ ✔ ✔
BAYOSAH001A .............. Manual Fresh Air Damper25 ........................................................................ 1½-3 1½-3 1½-3 1½-3
BAYOSAH002A .............. Manual Fresh Air Damper25 ........................................................................ 3½-4 3½-4 3½-4 3½-4
BAYQSTK300A .............. Quick Start Kit ............................................................................................... 1 Phase Only 1 Phase Only 1 Phase Only 1 Phase Only
BAYSQRD001A .............. 16" Round Duct Adapter0 ........................................................................... 1½-3 1½-3 1½-3 1½-3
BAYSQRD002A .............. 18" Round Duct Adapter0 ........................................................................... 1½-5 1½-5 1½-5 1½-5
BAYUTIL101A ................ Roof Curb Extension Kit ................................................................................ 1½-3 1½-3 1½-3 1½-3
BAYUTIL102A ................ Roof Curb Extension Kit ................................................................................ 3½-4 3½-4 3½-4 3½-4
1 Relay required with economizer on all 2/4WC*3 models.
2 Must use filter frame when economizer/fresh air kit is used.
3 Ships knocked down.
4 Dry bulb control standard with economizer.
5 Downflow Only.
6 Full perimeter curb for 2/4WC*3018-036A models.
7 Full perimeter curb for 2/4WC*3042-060A models.
8 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.
9 Do not use with programmable thermostats.
0 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
q BAYRLAY005A, required on all heat pump applications.
w BAYCOVR112,118A will not cover BAYSQRD002A applications

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PH-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

Table PH-12-A — Supplementary Heaters – Separate power source /power entry required
Model Shipping
Number Description Used With Weight
BAYHTRV105A 3.76/5.0 kW Heater (208/240V 1PH) 2/4WC*3018-060A1 9
BAYHTRV110A 7.50/10.0 kW Heater (208/240V 1PH) 2/4WC*3024-060A1 10
BAYHTRV115A 11.27/15.00 kW Heater (208/240V 1PH) 2/4WC*3030-060A1 14
BAYHTRV120A 15.0/20.0 kW Heater (208/240V 1PH) 2/4WC*3048-060A1 14
BAYHTRV305A 3.76/5.0 kW Heater (208/240V 3PH) 2/4WC*3018-060A3 9
BAYHTRV310A 7.50/10.0 kW Heater (208/240V 3PH) 2/4WC*3024-060A3 10
BAYHTRV315A 11.27/15.00 kW Heater (208/240V 3PH) 2/4WC*3030-060A3 14
BAYHTRV320A 15.00/20.0 kW Heater (208/240V 3PH) 2/4WC*3048-060A3 14
BAYHTRV405A 3.76/5.0 kW Heater (460V 3PH) 2/4WC*3018-060A4 9
BAYHTRV410A 7.50/10.0 kW Heater (460V 3PH) 2/4WC*3024-060A4 10
BAYHTRV415A 11.27/15.00 kW Heater (460V 3PH) 2/4WC*3030-060A4 14
BAYHTRV420A 15.00/20.0 kW Heater (460V 3PH) 2/4WC*3048-060A4 14

Table PH-12-B — Single Power Entry Kit/Heater Matrix:


Single Power Heater Unit Shipping
1
Entry Kit1 Model Model Weight
BAYSPEK060A BAYHTRV105A 2WC*3024-048A1 3
4WC*3018-036A1
BAYSPEK061A BAYHTRV305A 4WC*3036-060A3 7
BAYHTRV310A 4WC*3036-048A3
BAYHTRV405A 4WC*3036-060A4
BAYHTRV410A 4WC*3036-060A4
BAYHTRV415A 4WC*3036-060A4
BAYHTRV420A 4WC*3048-060A4
BAYSPEK062A BAYHTRV105A 4WC*3048-060A1 7
2WC*3060A1
BAYHTRV110A 2WC*3024-060A1
4WC*3036-060A1
BAYSPEK063A BAYHTRV115A 2WC*3030-060A1 7
4WC*3036-060A1
BAYHTRV120A 2WC*3048-060A1
4WC*3048-060A1
BAYSPEK064A BAYHTRV315A 4WC*3036-060A3 6
BAYHTRV320A 4WC*3048-060A3
BAYSPEK065A BAYHTRV310A 4WC*3060A3 7
1 All necessary fuses are included in kit

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PH-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 2 through 5 Tons

WCZ-F – XL 1600
WCY-G – XL 1400
WCX-G – XL 1200

Table PH-13-A — WCZ – XL 1600 Convertible Package Heat Pump


Cooling Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER HSPF (Btuh) H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
WCZ – 208-230/1/60
WCZ036F100B 15.60/12.00 7.65 36,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 27.1 40 80 R1/2
WCZ060F100B 15.05/10.50 8.10 58,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 679 43.5 70 82 R1/2
WCZ – 208-230/3/60
WCZ036F300B 15.60/12.00 7.65 36,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 19.6 30 82 R1/2
WCZ060F300B 15.05/10.50 8.10 58,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 679 30.9 45 82 R1/2

Table PH-13-B — WCY-G – XL 1400 Convertible Package Heat Pump


Cooling Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER HSPF (Btuh) H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
WCY – 208-230/1/60
WCY024G100B 13.70/11.90 7.90 24,500 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 387 15.8 25 80 R1

PHASED OUT
WCY030G100B 13.50/11.50 7.70 30,000 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 398 21.4 30 80 R2
WCY036G100B 13.50/11.55 7.95 37,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 27.4 40 80 R2
WCY042G100B 13.05/11.25 7.80 42,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 29.6 45 80 R2
WCY048G100A 13.75/12.00 7.60 49,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 38.1 60 84 R2
WCY060G100A 13.00/11.35 7.80 60,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 574 46.8 60 84 S

Table PH-13-C — WCX – XL 1200 Convertible Package Heat Pump


Cooling Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER HSPF (Btuh) H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
WCX – 208-230/1/60
WCX024G100B 12.80/11.50 7.60 25,800 29 x 36 x 56 (A) 10 x 171/2 189/16 x 111/16 387 17.1 25 80 R1
WCX030G100B 12.30/11.00 7.60 30,500 29 x 36 x 56 (A) 10 x 171/2 189/16 x 111/16 398 20.4 30 80 R2
WCX036G100B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 25.9 40 80 R2
WCX042G100B 12.20/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 25.9 40 80 R2
WCX048G100A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 37.2 55 84 R2
WCX060G100A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 45.4 70 84 R2

PHASED OUT
WCX – 208-230/3/60
WCX036G300B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 17.9 25 80 R2
WCX042G300A 12.10/10.60 7.90 42,500 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 18.8 30 80 R2
WCX048G300A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 27.8 40 84 R2
WCX060G300A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 30.1 45 84 R2
WCX – 460/3/60
WCX036G400B 12.30/10.90 7.60 38,000 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 468 9.7 15 80 R2
WCX048G400A 12.00/10.60 7.60 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 12.7 15 84 R2
WCX060G400A 12.00/10.70 8.20 58,500 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 21.1 30 84 R2
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PH-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

WCP – XE 1200
WCC – XE 1000

Table PH-14-A — WCP – XE 1200 Convertible Package Heat Pump


Cooling Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER HSPF (Btuh) H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
WCP – 208-230/1/60
WCP036F100B 12.30/10.9 7.6 38,000 29 x 36 x 62 (C) 10 x 171/2 189/16 x 111/16 468 25.9 40 80 R2
WCP048F100A 12.00/10.6 7.6 48,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 37.2 55 84 R2
WCP060F100A 12.00/10.7 8.2 60,000 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 576 45.4 70 84 R2

WCP – 208-230/3/60
WCP036F300B
WCP048F300A
WCP060F300A
WCP – 460/3/60
PHASED OUT
12.30/10.90
12.00/10.60
12.00/10.70
7.6
7.6
8.2
38,000
48,000
60,000
29 x 36 x 62 (C)
33 x 45 x 64 (D)
33 x 45 x 64 (D)
10 x 171/2
14 x 20
14 x 20
189/16 x 111/16
211/16 x 151/16
211/16 x 151/16
468
576
576
17.9
27.8
30.1
25
40
45
80
84
84
R2
R2
R2

WCP036F400B 12.30/10.90 7.6 38,000 29 x 36 x 62 (C) 10 x 171/2 189/16 x 111/16 468 9.7 15 80 R2
WCP048F400A 12.00/10.60 7.6 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 12.7 15 84 R2
WCP060F400A 12.00/10.70 8.2 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 576 17.7 25 84 R2

Table PH-14-B — WCC – XE 1000 Convertible Package Heat Pump


Cooling Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Dimensions (in.) Downflow Horizontal Weight Max Sound
Model No. SEER/EER HSPF (Btuh) H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
WCC – 208-230/1/60
WCC018F100B 10.00/9.60 6.8 18,000 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 337 17.0 25 80 R1
WCC024F100B 10.00/9.40 6.8 23,800 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 337 17.7 25 80 R1

PHASED OUT
WCC030F100B 10.00/9.50 6.8 29,800 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 359 23.4 40 80 R1/2
WCC036F100B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 383 26.0 40 80 R2
WCC042F100B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 400 31.2 50 80 R2
WCC048F100B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 37.2 60 84 R2
WCC060F100B 10.009.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 41.1 60 84 R2

WCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.


WCC036F300B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 459 19.4 30 80 R2
WCC042F300B 10.00/9.15 6.8 41,500 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 400 23 7 40 80 R2
WCC048F300B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 28.3 40 84 R2
WCC060F300B 10.00/9.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 31.5 45 84 R2
WCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.
WCC036F400B 10.00/9.50 6.8 36,000 29 x 36 x 55 (B) 10 x 171/2 189/16 x 111/16 359 10.2 15 80 R2
WCC048F400B 10.00/9.50 6.8 48,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 552 13.8 20 84 R2
WCC060F400B 10.00/9.50 6.8 60,000 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 547 16.3 25 84 R2
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Note: WCC-F models currently manufactured with sloped drain pans.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PH-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

A
B

EVAPORATOR COIL &


SUPPLY & BLOWER PANEL
RETURN PANEL
SPACER PANEL
WCCO42F ONLY

ECONOMIZER/FILTER
CORNER POST ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H

CONDENSOR COIL D
J D 29 MM
35 MM L (1 1/8")
M X
(1 3/8") X
Y
Y CONDENSATE DRAIN
L 19 MM (3/4") FEMALE NPT
K M
DOWNFLOW
HORIZONTAL RETURN OPENING
SUPPLY P
76 MM
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING

Table PH-15-A — WCZ – XL 1600 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
WCZ036F 64 36 293/16 189/16 111/16 69/16 111/8 17 181/2 25 171/2 10 3 83/4 33A
WCZ060F 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 221/4 25 20 14 31/2 85/16 34A

Table PH-15-B — WCY – XL 1400 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
WCY024G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 253/8 171/2 10 3 47/16 30A, 38A
WCY030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38A
WCY036G
WCY042G
WCY048G
WCY060G
64
64
651/4
651/4
PHASED OUT
36
36
45
45
291/16
291/16
333/8
333/8
189/16
189/16
211/16
211/16
111/16
111/16
151/16
151/16
69/16
69/16
415/16
415/16
111/8
111/8
91/8
91/8
17
17
2115/16
2115/16
191/4
191/4
241/4
241/4
271/2
271/2
281/2
281/2
171/2
171/2
20
20
10
10
14
14
3
3
31/2
31/2
83/4
83/4
85/16
85/16
30A, 38A, 33A
30A, 38A, 33A
30A, 38A, 34A
30A, 38A, 34A

Table PH-15-C — WCX – XL 1200 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
WCX024G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 253/8 171/2 10 3 47/16 30A, 38A
WCX030G 561/2 36 293/16 189/16 111/16 69/16 613/16 17 21 243/8 171/2 10 3 47/16 30A, 38A
WCX036G
WCX042G
WCX048G
WCX060G
64
64
651/4
651/4
PHASED OUT
36
36
45
45
291/16
291/16
333/8
333/8
189/16
189/16
211/16
211/16
111/16
111/16
151/16
151/16
69/16
69/16
415/16
415/16
111/8
111/8
91/8
91/8
17
17
2115/16
2115/16
191/4
191/4
241/4
241/4
271/2
271/2
281/2
281/2
171/2
171/2
20
20
10
10
14
14
3
3
31/2
31/2
83/4
83/4
85/16
85/16
30A, 38A, 33A
30A, 38A, 33A
30A, 38A, 34A
30A, 38A, 34A

Table PH-15-D— WCP – XE 1200 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
WCP036F 627/8 36 293/16 189/16 111/16 69/16 111/8 17 191/4 271/2 171/2 10 3 83/4 30A, 38A, 33A
WCP048F
WCP060F
643/8
643/8
45
45
331/8
331/8 PHASED OUT
211/16
211/16
151/16
151/16
415/16
415/16
91/8
91/8
2115/16
2115/16
241/4
241/4
281/2
281/2
20
20
14
14
31/2
31/2
85/16
85/16
30A, 38A, 33A
30A, 38A, 34A

Table PH-15-E — WCC – XE 1000 Dimensional Data - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.
Model A B C D E F G H J K L M N P BAYCURB0
WCC018F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 201/2 25 171/2 10 3 47/16 30A, 38A
WCC024F 551/4 36 253/16 189/16 111/16 69/16 613/16 17 201/2 25 171/2 10 3 47/16 30A, 38A

PHASED OUT
WCC030F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 2013/16 255/16 171/2 10 3 47/16 30A, 38A
WCC036F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 19 243/16 171/2 10 3 47/16 30A, 38A
WCC042F 551/4 36 293/16 189/16 111/16 69/16 613/16 17 1813/16 24 171/2 10 3 47/16 30A, 38A
WCC048F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 243/4 29 20 14 31/2 85/16 30A, 38A, 34A
WCC060F 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 243/4 29 20 14 31/2 85/16 30A, 38A, 34A
Note: WCC-F models currently manufactured with sloped drain pans.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Dual Fuel Heat Pump with
Auxiliary Gas Heat

• Climatuff® high efficiency compressor • Dual firing 20 and 25 MBTUH


• Shipped for horizontal application, heat exchangers (optional)
easily convertible to downflow • Top discharge condenser fan
• Heavy gauge steel cabinet with weather • Comfort-RTM enhanced performance on
resistant, powder paint DCY060F models (1ø and 3ø) only
• Attractive coil guard and trim ring • Demand defrost
• Direct spark (3-try) ignition • Water shed base pan
• Aluminized steel tubular heat exchanger • Liquid line filter-drier
• Optional filter rack fits inside unit • High efficiency outdoor fan motor with
• Ball-bearing induced draft combustion polarized plug
DCY blower • 2-speed (high for cooling, low for heating)
• Copper tube, aluminum plate fin coils direct-drive blower motor
• Restricted or non-restricted operating mode • Internal compressor protection
• Low profile horizontal duct take-offs • Protected pressure taps for refrigerant
• One screw convertible to downflow checks
• Built-in downflow duct flanges • Standard operations to 55°F as manufac-
• Single curb fits all models tured
• Aluminized multi-port-in-shot burner • Low ambient cooling to 0°F with accessories
BAYLOAM011A

Table PH-16-A — DCY – XL 1200 Convertible Dual Fuel Heat Pumps


Unit Cooling Gas Heating Cabinet Supply/Return Supply/Return Shipping
Model Capacity Capacity Output SEER/ Dimensions (in.) Downflow Horizontal Weight Max. Sound
No. (Btuh) 1
(Btuh)1 EER AFUE % HSPF H x W x L W x L H x W (Ibs.) MCA* Fuse* Rating Comp.
DCY – 208-230/1/60
DCY024F1L0B 25,800 32 or 38 12.80/11.50 78 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 446 17.1 25 80 R1
DCY030F1M0B 30,400 45 or 57 12.20/11.00 78 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 471 20.4 30 80 R2
DCY036F1H0B 38,000 64 or 80 12.30/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 25.9 40 80 R2
DCY048F1H0B 48,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 37.2 55 84 R2
DCY060F1M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 45.4 70 84 R2

PHASED OUT
DCY – 208-230/3/60
DCY036F3H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 17.9 25 80 R2
DCY048F3H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 27.8 40 84 R2
DCY060F3M0A 58,500 80 or 98 12.00/10.70 80 8.20 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 30.1 45 84 R2
DCY – 460/3/60
DCY036F4H0B 38,000 64 or 80 12.00/10.90 80 7.60 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 486 9.7 15 80 R2
DCY048F4H0B 49,000 80 or 98 12.00/10.60 80 7.60 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 12.7 15 84 R2
DCY060F4M0A 58,500 80 or 98 12.00/10.70 80 8.21 33 x 45 x 65 (D) 20 x 14 211/16 x 151/16 628 21.1 30 84 R2

Table PH-16-B — Accessories


Model No. Description Used With
BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All DCY Models
BAYECMT003A
BAYLPKT022A
BAYLPSS001A PHASED OUT Extreme Conditions Mounting Kit (Slab or Rack Mount)
LP Conversion Kit
LP Conversion Kit w/stainless burners
Additional Accessories are listed on page PH-19.
1 Unit ships standard in high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit..
All DCY Models
All DCY Models
All DCY Models

* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PH-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

DCY WCZ WCY-G WCX-G WCP-F WCC-F


Table PH-17-A — Features 2-5 3-5 2-5 2-5 3-5 11/2-5
• Impack Plus™ feature set ............................................................................................ — ✔ ✔ ✔ ✔ —
• Climatuff® Compressor (2) .......................................................................................... — ✔ — — — —
• Climatuff® Compressor (1) .......................................................................................... ✔ — ✔ ✔ ✔ ✔
• Comfort “R”™ mode option .......................................................................................... 5 ✔ ✔ 5 5 —

PHASED OUT
• DuraTuff™ Plate Fin coil ............................................................................................... ✔ ✔ ✔ ✔ ✔ ✔
• Coil Sav’RTM coil guard ................................................................................................. ✔ ✔ ✔ ✔ — —

T
• Crankcase heater .......................................................................................................... ✔ ✔ ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔ ✔

U
• Deluxe XL Lexan nameplate .......................................................................................... —
• Demand defrost control with Lite Port/Stored diagnostics ............................................. ✔ ✔ ✔ ✔ ✔ ✔

O
• GE ECM variable speed fan w/potted motor module ..................................................... 5 ✔ ✔ 5 5 —
• Horizontal convertible to downflow ................................................................................ ✔ ✔ ✔ ✔ ✔ ✔

ED
• Polarized plugs .............................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔
• Powder paint .................................................................................................................. ✔ ✔ ✔ ✔ ✔ ✔

AS
• Time/temperature defrost .............................................................................................. — — — — —
• Two-stage cooling .......................................................................................................... — ✔ — — — —
• Two-stage heating .......................................................................................................... — ✔ ✔ — — —

PH
• 5-year limited compressor only warranty (Commercial use) .......................................... ✔ ✔ ✔ ✔ ✔ ✔
• 5-year limited heat exchanger warranty (Commercial use) ........................................... ✔ — — — — —
• 5-year limited compressor and coil warranty (Residential use) ..................................... — — — — — ✔
• 5-year limited parts warranty (Residential use) ............................................................. ✔ ✔ ✔ ✔ — —
• 5-year limited parts warranty (Residential use) ............................................................. — — — — — ✔
• 1-year limited coil and parts warranty (Commercial use) .............................................. ✔ ✔ ✔ ✔ ✔ ✔
• 10-year limited compressor and coil warranty (Residential use) ................................... ✔ — — — — —
• 10-year limited compressor and outdoor coil warranty (Residential use) ...................... ✔ ✔ ✔ ✔ — —
• 20-year heat exchanger warranty (Residential use) ...................................................... ✔ — — — — —

Table PH-17-B — Comfort Controls


BAY28X138A ........... Auto 2-Stage Heating/1-Stage Cooling ............................................. ✔ ✔ ✔ ✔
BAY28X153A ........... Auto 3-Stage Heating/2 Stage Cooling ............................................. ✔ ✔ ✔ ✔
PHASED OUT

BAY28X1901 ........ Locking Thermostat Cover ................................................................ ✔ ✔ ✔ ✔


BAY41X1711 ........ 5 or 7 Minute Delay Relay ................................................................. ✔ ✔ ✔ ✔

T
BAYASCT001A1 ....... Anti-short Cycle Timer ...................................................................... — — — —
Zone Sensors Section

PHZone Sensors Section


See Comfort Controls/

See Comfort Controls/

U
BAYSTAT033A ......... Outdoor Thermostat ......................................................................... ✔ ✔ ✔ ✔
BAYSTAT040B3 ...... Prog. Electronic Setback 3 Htg/2 Clg ................................................ ✔ — — —

O
BAYSTAT239A ......... Manual 2-Stage Heating/1 Cooling ................................................... ✔ ✔ ✔ ✔
BAYSTAT240A ......... Manual 2 Heating/1 Cooling with Subbase ........................................ ✔ ✔ ✔ ✔
ED
BAYSTAT253A ......... Humidity Control ............................................................................... — — — —
TAYSENS100A ........ Outdoor Temp. Sensor (with case) .................................................... ✔ ✔ ✔ ✔
AS

TAYSTAT500C ......... XT 500C Manual Prog. 3 Htg/2 Clg ................................................... ✔ ✔ ✔ ✔


TAYSTAT540 ............ Prog.,5/2 Day, Manual ...................................................................... ✔ ✔ ✔ ✔
TAYSTAT570 ............ Electronic, 2Htg/1Clg (Non Prog.) ..................................................... ✔ — — —
TAYSTAT575 ............ Electronic, 3Htg/2Clg (Non Prog.) ..................................................... ✔ — ✔ ✔
TCONT402A ............ 3Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔
TCONT602A ............ 2Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔
TCONT802A ............ 3Htg/2Clg (Heat Pump/A/C) ............................................................. ✔ ✔ ✔ ✔
TCONT803A ............ 3Htg/2Clg (Heat Pump/A/C) w/Humidity Control ............................... ✔ ✔ ✔ ✔
1 Not for use with programmable thermostats.
2 Subbase used with BAYSTAT040B.
3 Use with BAYBASE007A.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PH-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

Table PH-18-A — Supplementary Heaters – Single Point Entry Kit/Heater Matrix


Used With Single Used With
Model No. Description 12
Power Entry Kit12 Packaged Heat Pump Unit
BAYHTRN105A ... 3.74/4.98 kW Heater (208/240V 1PH) ....... BAYSPEK047A ..... WCC018-042F1, WCY024-042G1, WCX024-042G1,
WCZ036F1
BAYHTRN108A ... 5.76/7.68 kW Heater (208/240V 1PH) ....... BAYSPEK047A ..... WCC018-024F1, WCY/WCX024G1
BAYSPEK049A ..... WCC030-042F1,WCY030-042G1,WCX030-042G1,
WCZ036F1
BAYHTRN110A ... 7.47/9.96 kW Heater (208/240V 1PH) ....... BAYSPEK049A ..... WCC024-048F1, WCY024-048G1 ,WCX024-048G1, WCZ036F1
BAYSPEK053A ..... WCC/WCZ060F1, WCY060G1,WCX060G1
BAYHTRN112A ... 8.65/11.52 kW Heater (208/240V 1PH) ..... BAYSPEK049A ..... WCC024-048F1, WCY024-048G1,WCX024-048G1, WCZ036F1
BAYSPEK053A ..... WCC/WCZ060F1,WCY060G1, WCX060G1
BAYHTRN115A ... 11.21/14.94 kW Heater (208/240V 1PH) .... BAYSPEK048A ..... WCC030-048F1, WCY030-048G1, WCX030-048G1, WCZ036F1
BAYSPEK052A ..... WCC/WCZ060F1, WCY060G1, WCX060G1
BAYHTRN117A ... 12.98/17.28 kW Heater (208/240V 1PH) .... BAYSPEK048A ..... WCC030-048F1, WCY030-048G1, WCX030-048G1, WCZ036F1
BAYSPEK052A ..... WCC/WCZ060F1, WCY060G1, WCX060G1
BAYHTRN123A ... 17.2/23.04 kW Heater (208/240V 1PH) ..... BAYSPEK048A ..... WCC048F1, WCY048G1, WCX048G1
BAYSPEK052A ..... WCC/WCZ060F1,WCY/ WCX060G1
BAYHTRN306A ... 4.89/6.25 kW Heater (208/240V 3PH) ....... BAYSPEK047A ..... WCC/WCZ036-060F3, WCX036-060G3
BAYHTRN310A ... 7.45/9.96 kW Heater (208/240V 3PH) ....... BAYSPEK047A ..... WCC/WCZ036F3, WCP036 - 060F3, WCX036G3
BAYSPEK051A ..... WCZ060F3
BAYHTRN310F ... 7.45/9.96 kW Heater (208/240V 3PH) ....... BAYSPEK051A ..... WCZ060F3, WCX/WCY036-060G3, WCP036-060F3
BAYSPEK047 ........ WCZ036F3
BAYHTRN315A ... 11.25/14.90 kW Heater (208/240V 3PH) .... BAYSPEK051A ..... WCC/WCZ036-060F3, WCX036-060G3, WCP036-060F3
BAYHTRN320A ... 14.96/19.92 kW Heater (208/240V 3PH) .... BAYSPEK051A ..... WCC042-060F3, WCX042-060G3, WCZ060F3,
WCP042-060F3
BAYHTRN330A ... 22.41/29.80 kW Heater (208/240V 3PH) .... BAYSPEK050A ..... WCC/WCZ060F3, WCX060G3, WCP060F3
BAYHTRN406A ... 6kW Heater (480V 3PH) .......................... BAYSPEK047A ..... WCC/WCP036-060F4, WCX036-060G4
BAYHTRN410A ... 9.96 kW Heater (480V 3PH) ..................... BAYSPEK047A ..... WCC036-060F4, WCP036-060F4, WCX036-060G4
BAYHTRN410F ... 9.96 kW Heater (460V 3PH) ..................... BAYSPEK047A ..... WCP036-060F4, WCX036-060G4
BAYHTRN415A ... 14.90 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC036-060F4, WCP036-060F4, WCX036-060G4
BAYHTRN420A ... 19.92 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC048-060F4, WCP048-060F4, WCX048-060G4
BAYHTRN430A ... 29.80 kW Heater (480V 3PH) ................... BAYSPEK047A ..... WCC060F4, WCP060F4, WCX060G4
1 All necessary fuses are included in kit.
2 Relay required with economizer on WCZ-F models.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PH-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Convertible 1½ through 5 Tons

DCY WCZ WCY-G WCX WCP WCC


Table PH-19-A — Accessories 2-5 3-5 2-5 2-5 3-5 1½-5
BAY24X045 ......... Indoor Fan Delay Kit .................................................................................. — — — 2-5 3-5 11/2-5
BAYASCT00168 Anti-Short Cycle Timer ............................................................................... 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYCURB030A ... Roof Curb (Flat Roof)3 (14 H x 34 W x 531/8 L) .......................................... 2-5 3-5 2-4 2-5 3-5 11/2-5
BAYCURB033A ... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 34 W x 605/8 L) .................... 2-3 3 3 31/2 31/2 —
BAYCURB034A ... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 43 W x 621/16 L) .................... 4-5 5 4-5 4-5 4-5 4-5
BAYCURB038A ... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 34 W x 531/8 L) .................... 2-5 3-5 2-4 2-5 3-5 11/2-5
BAYDMPR040A ... 0-25% Manual Fresh Air Damper (Downflow Only)2 ................................ 2-3 3 2-31/2 2-31/2 3 11/2-31/2

T
PHASED OUT
BAYDMPR041A ... 0-25% Manual Fresh Air Damper (Downflow Only)2 ................................ 4-5 5 4-5 4-5 4-5 4-5
BAYDMPR050A ... Motorized Fresh Air Damper ...................................................................... 4-5 — 4-5 4-5 4-5 4-5
BAYDUCT004A ... 12" Round Duct Adapters (2 per Box) ....................................................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2
BAYDUCT005A ... 14" Round Duct Adapters (1 per Box) ....................................................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2

ED OU
BAYECMT002A ... Extreme Conditions Mounting Kit (Curb Mount) ......................................... 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYECMT003A ... Extreme Conditions Mounting Kit (Slab or Rack Mount) ............................. 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYECON054B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 2-3 3 2-31/2 2-31/2 3 11/2-31/2
BAYECON055B ... 0-100% Mod. Downflow Economizer with Bar Relief1245 ..................... 4-5 5 4 -5 4-5 4-5 4-5
BAYECON073A ... 0-100% Mod. Horizontal Economizer1245 ............................................ 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYENTH001A ... Enthalpy Control (Solid State)4 ................................................................ 2-5 3-5 2-5 3-5 3-5 11/2-5
BAYFLTR012A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... — — 2-21/2 2-21/2 — 21/2-31/2
BAYFLTR013A ..... Filter Frame2 (20 x 25 x 1" filter not included) ........................................... 2-3 3 3-31/2 3-31/2 3 —
BAYFLTR014A ..... Filter Frame2 (3-10 x 25 x 1" filter not included) ........................................ 4-5 5 4-5 4-5 4-5 4-5
BAYFLTR015A ..... Filter Frame2 (20 x 20 x 1" filter not included) ........................................... — — — — — 11/2-2
BAYFLTR017A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ — — 2-21/2 2-21/2 — 21/2-31/2
BAYFLTR018A ..... Filter Frame2 (1-20 x 25 x 2" filter not included) ........................................ 2-3 3 3-31/2 3-31/2 3 —
BAYFLTR019A ..... Filter Frame2 (2-16 x 25 x 2" filter not included) ........................................ 4-5 5 4 4-5 4-5 4-5
BAYGARD016A ... Condenser Coil Guard ............................................................................... — — — — — 11/2-2
BAYGARD017A ... Condenser Coil Guard ............................................................................... — — — — — 21/2-3
BAYGARD019A ... Condenser Coil Guard ............................................................................... — — — — — 31/2
BAYGARD022A ... Condenser Coil Guard ............................................................................... — — — — — 4-5
BAYHSMT043A ... High Static Motor (230/460) 3/4HP ............................................................ 21/2-3 — — 21/2-31/2 21/2-3 21/2-31/2
BAYHSMT044A ... High Static Motor (230/460) 1HP ............................................................... 4 — — 4 4 4-5

PHAS
PHASED OUT

BAYHSMT045A ... High Static Motor (208) 1HP ...................................................................... 4 — — 4 4 4-5


BAYHSMT056A ... High Static Motor (208) 3/4HP ................................................................... 21/2-3 — — 21/2-31/2 3 21/2-31/2
BAYINDK001A* ... Insulated Deck Pan for A & B Cabinet ........................................................ — — 2-21/2 2-21/2 — 11/2-3
BAYINDK002A** .. Insulated Deck Pan for C Cabinet .............................................................. 2-3 3 3-31/2 3-31/2 3 —
BAYINDK003A*** . Insulated Deck Pan for D Cabinet .............................................................. 4-5 5 4-5 4-5 4-5 4-5
BAYKSKT010A .... Quick Start Kit (Single Phase Units Only) ................................................. — — — — — 11/2-5
BAYLIFT002B ...... Lifting Lug Kit ............................................................................................ 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYLOAM011A ... Evaporator Defrost Control Kit ................................................................... 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYLOAM323A ... Dual Voltage Electronic Head Pressure Control7 (use w/BAYRLAY005) ........... 2-5 — 2-5 2-5 3-5 11/2-5
BAYLOFR001 ...... Low Fire Kit ................................................................................................ 2 — — — — —
BAYLOFR004 ...... Low Fire Kit ................................................................................................ 21/2 -3 — — — — —
BAYLOFR005 ...... Low Fire Kit ................................................................................................ 3 — — — — —
BAYLOFR007 ...... Low Fire Kit ................................................................................................ 4-5 — — — — —
BAYLPKT022A .... LP Conversion Kit ...................................................................................... 2-5 — — — — —
BAYLPSS001A .... LP Conversion Kit with SS Burners ............................................................ 2-5 — — — — —
BAYMOTR307A ... 200-230V 1/2HP OD Fan Motor (use w/BAYLOAM323A&BAYRLAY005) .......... 2-5 — 2-5 2-5 3-5 11/2-5
BAYMOTR406A ... 460V 1/2HP Outdoor Fan Motor (use w/BAYLOAM323A&BAYRLAY005) ......... 3-5 — — 3-5 3-5 3-5
BAYOSAC001A ... Outside Air Controller ............................................................................. — 3-5 — — — —
BAYRLAY002 ....... Time Delay Relay ..................................................................................... — — 2-5 2-5 2-5 —
BAYRLAY004A .... Economizer Relay Kit1 ............................................................................. 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYRLAY005A7 . Relay Required with BAYLOAM323A8 ...................................................... 2-5 — 2-5 2-5 3-5 11/2-5
BAYSTAT023 ....... Remote Potentiometer for All Economizers ................................................ 2-5 3-5 2-5 2-5 3-5 11/2-5
BAYUTIL030A ..... Roof Curb Utility Extension Kit for BAYCURB030, 038A ............................ — — — — — 11/2-5
BAYUTIL034A ..... Roof Curb Utility Extension Kit for BAYCURB034A .................................... — — — — — 4-5
1 BAYRLAY004A required with economizer. * Currently Shipped with BAYCURB038A.
2 Must use filter frame when economizer/fresh air kit is used. ** Currently Shipped with BAYCURB033A.
3 Ships knocked down. *** Currently Shipped with BAYCURB034A.
4 Dry bulb control standard with economizer.
5 2-Stage thermostat provides additional energy savings if simultaneous
economizer and compressor operation is expected.
6 Do not use with programmable thermostats.
7 May require motor change. (See Installers Guide.)
8 Activated on Power On.
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-19 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
2 through 3½ Tons

WCK • Sloped composite drain pan


• Waterproof closed-cell foam evaporator base
• Climatuff® compressor insulation
• Compressor motor overload protection • Heavy gauge steel cabinet
• Internal pressure relief valve • Weather resistant Powder Paint
• Demand Defrost Control w/Lite Port/Stored • Double powder painted G90 base pan with
Diagnostics dimpled feet
• Copper tube, aluminum plate fin coils • Wrap-around vinyl-coated wire coil guards
• Static (0.5") ESP Indoor Blower System with • U.L. listed
two-speed blower motor • 5-year limited warranty on compressor and
• Shaft-Down OD fan system for quiet operation 5-year on all other parts (Residential use)
(good neighbor) • Optional extended warranties
Table PC-20-A — XE 1200 — Cooling w/5/10-15 kW Electric Heat - Single Phase (208/230/1/60)
Cooling Dimensions Round Round Shipping
Unit Capacity (in.) Supply Return Weight Sound
Tons Model No. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) Rating Compressor
2 WCK024A100A 12.50/11.00 25,000 31 x 32 x 44 (**) 14" 14" 348 73 R1
21/2 WCK030A100A 12.30/10.75 30,500 31 x 32 x 44 (**) 14" 14" 350 73 S
3 WCK036A100A 12.75/10.70 36,000 31 x 32 x 44 (**) 14" 14" 370 73 S
31/2 WCK042A100A 12.00/10.50 42,000 31 x 32 x 44 (**) 14" 14" 372 73 S

Table PC-20-B — Electric Heater Data


USING SINGLE SUPPLY CIRCUIT HEATER ONLY
WCK HEAT PUMP SUPPLY CIRCUIT
Max. Fuse Canda Max. Fuse Canda
Unit Electric Rated Heater or HQCR Only Max. or HQCR Only Max.
Model Heater Voltage Kw MCA (2) CKT BKR CKT BKR MCA (7) CKT BKR CKT BKR
Model 208/240 Size (4) Size (5) Size (4) Size (5)
NONE** 208/240 NONE** 17/17(3) 25/25 25/25 NONE NONE NONE
WCK024A1 (6) BAYHTRK105A 208/240 3.74/4.98 40/43(3) 45/45 50/50 23/26 25/30 25/30
BAYHTRK111A 208/240 7.47/9.96 62/70(3) 70/70 70/70 45/53 45/60 50/60
NONE** 208/240 NONE** 21/21(3) 30/30 30/30 NONE NONE NONE
WCK030A1 (6) BAYHTRK105A 208/240 3.74/4.98 44/47(3) 50/50 50/50 23/26 25/30 25/30
BAYHTRK110A 208/240 7.47/9.96 66/73(3) 70/80 70/100 45/53 45/60 50/60
NONE** 208/240 NONE** 25/25(3) 40/40 40/40 NONE NONE NONE
WCK036A1 (6) BAYHTRK105A 208/240 3.74/4.98 48/51(3) 50/60 50/60 23/26 25/30 25/30
BAYHTRK110A 208/240 7.47/9.96 70/77(3) 70/80 70/100 45/53 45/60 50/60
BAYHTRK115A 208/240 11.18/14.94 93/103(3) 100/110 100/110 58/78 70/80 70/100
NONE** 208/240 NONE** 28/28(3) 45/45 45/45 NONE NONE NONE
WCK042A1 (6) BAYHTRK105A 208/240 3.74/4.98 51/54(3) 60/60 60/60 23/26 25/30 25/30
BAYHTRK110A 208/240 7.47/9.96 73/80(3) 80/80 100/100 45/53 45/60 50/60
BAYHTRK115A 208/240 11.18/14.94 96/106(3) 100/110 100/125 68/78 70/80 70/100
** Unit electrical information with no electric heat installed. 3. Field wire must be rated at least 75°C.
1. Any power supply and circuits must be wired and protected in 4. The HACR circuit breaker is for U.S.A. installations only.
accordance with local electrical codes. 5. For Canada installation reference only.
2. The MCA values listed are for electric heater and heat pump unit. 6. BAYHTR111A only approved for WCK024A1.
7. The MCA values listed are for electric heater only.
Table PC-20-C — Accessories/Comfort Controls
Model No. Description Used With
BAY28X1842 Subbase Auto/Man. Changeover BAY28X183
BAY28X1853 Subbase Man. Changeover BAY28X182,183
BAY28X1872 Subbase Auto Changeover BAY28X182,183
BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All WCK Models
BAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All WCK Models
BAYCOVR100A Wallcover Plate TAYSTAT371
TAYSENS100A Outdoor Temperature Sensor (with case) TAYSTAT300
TCONT402A 3Heat/2Clg (Heat Pump/A/C) All WCK Models
TCONT602A 2Heat/2Clg (Heat Pump/A/C) All WCK Models
TCONT802A 3Heat/2Clg (Heat Pump/A/C) All WCK Models
TCONT803A 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control All WCK Models
A/M = Automatic or Manual Changeover
1 Requires subbase.
2 Requires BAY24X042 relay when used with electric heaters.
3 Specially designed for electric heater application (instant on fan).
For information on Roof Curbs and
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Roof Curb Adaptors, please refer to
the Accessories/Information Tab.
WCK models will be upgraded in the 1st Quarter of 2006.
For complete equipment / combination
Effective 1/1/06 PH-20 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Heat Pump
Over/Under 2 through 5 Tons

• Climatuff® compressor • Powder paint


• Over(Supply)/Under (Return) air configuration • Top discharge – quieter operation
• Electric heat accessory fits inside unit casing • 5-year limited compressor warranty
for lower installation cost • 5-year limited coil and parts warranty
• Electronic time/temperature defrost control • Variable speed direct drive blower motor on
system WCH048-060F models
• Demand Defrost Control w/Lite Port/stored
diagnostics
Table PH-21-A — WCH – Over/Under Horizontal Unit
WCH Unit Power Supply Nom. Cap. Dimensions Shipping
Model Volts/ Cooling (in.) Weight Max Sound
No. Phase/Hz SEER/EER HSPF (Btuh) H x W x L (lbs.) MCA* Fuse* Rating Comp.
Single Phase
WCH024B100C 208-230/1/60 12.40/10.80 8.0 24,500 303/8 x 315/8 x 44 324 17.2 25 79 R1
WCH030B100C 208-230/1/60 12.05/10.80 7.7 30,500 303/8 x 315/8 x 44 343 19.3 30 79 R2
WCH036B100C 208-230/1/60 12.05/10.50 8.0 36,400 303/8 x 315/8 x 44 378 25.1 40 79 R2
WCH042B100C 208-230/1/60 12.05/10.70 8.0 40,500 303/8 x 315/8 x 44 378 25.1 40 79 R2
WCH048F100A 208-230/1/60 13.50/12.00 8.0 49,000 331/8 x 45 x 58 447 37 50 84 S
WCH060F100A 208-230/1/60 13.00/11.30 8.2 60,000 331/8 x 45 x 58 457 47 60 84 S

Tons Supply H x W Return H x W


2 – 31/2 83/8 x 273/8 163/4 x 273/8
4–5 81/2 x321/32 1915/16 x 321/32

Table PH-21-B — WCH – Over/Under Horizontal Unit


Unit Power Supply Nom. Cap. Dimensions Shipping
Model Volts/ Cooling (in.) Weight Max Sound
No. Phase/Hz SEER/EER HSPF (Btuh) H x W x L (lbs.) MCA* Fuse* Rating Comp.
Three Phase
WCH036B300C 208-230/3/60 12.05/10.50 7.4 36,000 303/8 x 315/8 x 44 378 17.8 25 82 R2
WCH042B300C 208-230/3/60 12.05/10.70 7.5 41,000 303/8 x 315/8 x 44 378 19.4 30 82 R2

WCH036B400C 460/3/60 12.05/10.50 7.4 36,000 303/8 x 315/8 x 44 378 9.7 15 82 R2


WCH042B400C 460/3/60 12.05/10.70 7.5 41,000 303/8 x 315/8 x 44 378 10.7 15 82 R2

Tons Supply H x W Return H x W WCH models will be upgraded in


3 – 31/2 83/8 x 273/8 163/4 x 273/8 the 1st Quarter of 2006.
Dimensions are in inches. See Outline Dimensions.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

422mm
[16-5/8]

311mm
[12-1/4]

LEFT SIDE
RIGHT SIDE

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-21 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Heat Pump
Over/Under 2 through 5 Tons

Table PH-22-A— Supplementary Heaters – Heater Matrix


Model No. Power Supply kW Ratings Used With
BAYHTRC106A 208/240/1/60 4.33/5.76 kW WCH024-042B100B, 048F1, 060F1
BAYHTRC108A 208/240/1/60 6.12/8.16 kW WCH024-042B100B
BAYHTRC110A 208/240/1/60 7.93/10.56 kW WCH048F1 only
BAYHTRC111A 208/240/1/60 7.98/10.56 kW WCH024-042B100B, 060F1
BAYHTRC112A 208/240/1/60 8.65/11.52 kW WCH024-042B100B
BAYHTRC117A 208/240/1/60 12.98/17.28 kW WCH030-042B100B, 048F1, 060F1

Model No. Power Supply kW Ratings Nominal BTUH No. of Stages Used With
BAYHTRC306A 208/240/3/60 4.33/5.76 14,800/19,700 1 WCH036-042B300B
BAYHTRC312A 208/240/3/60 8.65/11.52 29,500/39,300 1 WCH036-042B300B
BAYHTRC317A 208/240/3/60 12.98/17.28 44,300/59,000 1 WCH036-042B300B

BAYHTRC406A 480/3/60 5.76 19,700 1 WCH036-042B400B


BAYHTRC412A 480/3/60 11.52 39,300 1 WCH036-042B400B
BAYHTRC417A 480/3/60 17.28 59,000 1 WCH036-042B400B
Table PH-22-B — Accessories/Comfort Controls
Model No. Description Used With
BAY28X138A ....................... 2-Stg. Heat/1-Stg. Cool Auto. Thermostat .......................................... All WCH Models
BAY28X153A ....................... Auto. 3 Stg. Htg./2 Stg Clg. ................................................................ All WCH Models
BAYASCT00114 ............... Anti-Short Cycle Timer ...................................................................... All WCH Models
BAYBASE007A3 ............... 3-Heat/2-Cool Heat Pump ................................................................. BAYSTAT040B
BAYECMT002A ................... Extreme Conditions Mounting Kit (Curb Mount) ................................ All WCH Models
BAYECMT003A ................... Extreme Conditions Mounting Kit (Slab or Rack Mount) .................... All WCH Models
BAYLOAM011A ................... Low Ambient Cooling Kit ................................................................... All WCH Models
BAYSTAT033A ..................... Outdoor Thermostat .......................................................................... All WCH Models
BAYSTAT040B ..................... Programmable (used with BAYBASE) ............................................... All WCH Models
BAYSTAT239A ..................... 2-Stg. Heat/1-Stg. Cool Manual Thermostat ...................................... All WCH Models
BAYSTAT240A ..................... Manual 2 Heat/1 Cool with Subbase ................................................. All WCH Models
TAYASCT501A4 ................. 5 minute delay relay .......................................................................... All WCH Models
TAYSENS100A .................... Outdoor Temp. Sensor ....................................................................... TAYSTAT500C
TAYSTAT500C ..................... XT500C Prog.,7 Day, Man/Auto ........................................................ All WCH Models
TAYSTAT540 ....................... Prog.,5/2 Day, Manual ....................................................................... All WCH Models
TAYSTAT570 ....................... Electronic, 2Htg/1Clg (Non Prog.) ..................................................... All WCH Models
TCONT402A ........................ 3Heat/2Clg (Heat Pump/A/C) ............................................................ All WCH Models
TCONT602A ........................ 2Heat/2Clg (Heat Pump/A/C) ............................................................ All WCH Models
TCONT802A ........................ 3Heat/2Clg (Heat Pump/A/C) ............................................................ All WCH Models
TCONT803A ........................ 3Heat/2Clg (Heat Pump/A/C) w/Humidity Control ............................. All WCH Models
1 Not for use with programmable thermostats.
2 BAYSENS026A must be used with BAYSENS025A.
3 Subbase used with BAYSTAT040B.
4 Activated on Power Off.
* Heaters must have an “A” in eleventh digit to work on WCH models.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PH-22 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package HP Manufactured
Housing – 2½ through 3½ Tons

WCM
• Climatuff® compressor • Crankcase heater
• High efficiency performance • Protected pressure taps for refrigerant
• Two-speed evaporator blower motor checks
• Round duct connections for manufactured • Heavy gauge steel cabinet with weather
housing applications resistant, baked enamel finish
• Quiet operating top condenser air discharge • Fully insulated air handling compartment
• Copper tube/aluminum fin coils • Convenient access panels
• Totally enclosed, permanently lubricated • 5-year limited compressor and coil warranty
condenser fan motor (Residental)
• Hermetically sealed compressor with • 5-year limited parts warranty
internal relief valve (Residental)
• Fully charged R-22 system • 5-year compressor only limited warranty
• Sloped Drain Pan (Commercial)
• Liquid line filter-drier • 1-year limited parts warranty (Commercial)
• Heating expansion device/cooling FCCV
Table PH-23-A — Mobile Home Heat Pumps (208-230/1/60)
Unit Cooling Dimensions Round Round Shipping
Model Capacity (in.) Supply Return Weight Max Sound
No. SEER/EER (Btuh) H x W x L Opening Opening (Ibs.) MCA* Fuse* Rating Comp.

PHASED OUT
WCM030F100B 10.0/9.50 29,800 29 x 36 x 55 (B) 12 12 376 23.4 35 80 R1
WCM036F100B 10.0/9.50 36,000 29 x 36 x 55 (B) 12 12 406 26.0 40 80 R2
WCM042F100B 10.09.20 41,500 29 x 36 x 55 (B) 14 14 416 31.8 50 80 R2

Table PH-23-B — Supplementary Heaters – Separate Power Source/Power Entry Required


Model No. Description Used With
BAYHTRN105A 3.74/4.98 kW Heater (208/240 volts) All WCM-F Models

PHASED OUT
BAYHTRN108A 5.76/7.68 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN110A 7.47/9.96 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN112A 8.65/11.52 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN115A 11.21/14.94 kW Heater (208/240 volts) All WCM-F Models
BAYHTRN117A 12.98/17.28 kW Heater (208/240 volts) All WCM-F Models

Table PH-23-C — Accessories


Model No. Description Used With
BAYECMT002A Extreme Conditions Mounting Kit (Curb Mount) All WCM Models
BAYECMT003A Extreme Conditions Mounting Kit (Slab or Rack Mount) All WCM Models
BAYFLTR012A
BAYGARD017A
BAYGARD019A
BAYHSMT043A
BAYKSKT010A
PHASED OUT Filter Frame (20 x 25 x 1" filter not included)
Condenser Coil Guard
Condenser Coil Guard
High Static Motor
Quick Start Kit
All WCM-F Models
WCM030, 036F
WCM042F
All WCM-F Models
All WCM-F Models

Table PH-23-D — Comfort Controls


Model No. Description Used With
BAY28X138A Auto Changeover All WCM Models
BAYSTAT033A Outdoor Thermostat All WCM Models
BAYSTAT239A Manual Heat Pump All WCM Models
TAYSTAT500C
TCONT402A
TCONT602A
TCONT802A
TCONT803A
PHASED OUT XT 500C Manual Programmable 3 Htg/2 Clg
3Heat/2Clg (Heat Pump/A/C)
2Heat/2Clg (Heat Pump/A/C)
3Heat/2Clg (Heat Pump/A/C)
3Heat/2Clg (Heat Pump/A/C) w/Humidity Control
All WCM Models
All WCM Models
All WCM Models
All WCM Models
All WCM Models
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PH-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ 3-10 ton
Packaged Heat Pumps

Standard Features:
• Trane built scroll compressors on all 4-10 ton units. 3 ton unit has a Reciprocating
Compressor
• ReliaTel™ Controls (See page PC-35 for ReliaTel™ Control Information)
• Colored and numbered wiring
• Provisions for through the Base Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• 2" throwaway filters provided on 6-10 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Single point power for electric Heat
• Low Ambient cooling to 0°F
Featuring • 5 - year Limited Compressor Warranty
A New Look for a New Century • 1 - year Limited Parts Warranty
Beveled Top Added Flexibility
Smoother Design • Convertible airflow
Small compact cabinet • Fork lift openings on three sides of unit
Recessed access handles • Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options


• Through-the-Base — Electrical
• Convenience Outlet — Powered or unpowered
• Unit Disconnect Switch
• Smoke Detectors — Supply, return, or both
• Condenser Coil Coating
• Hinged Access Service Panels
• Discharge Air Sensor
• Fan Fail and Clogged Filter Switches
• Condenser Coil Guard — Hail Protection Quality
• TCI (Trane Communication Interface)
• LonTalk (Communication Interface)
• 2" Pleated Media filters
• Phase Monitor

The same Trane Quality and


Reliability … with added Flexibility!

For complete equipment / combination


Effective 1/1/06 PH-24 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Heat Pump
Convertible 3-10 Tons

Table PH-25-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor Controls


Cooling Cabinet Shipping
Unit 2
Performance2 Capacity Dimensions (in.) Downflow Downflow Weight Max1
Tons 3
Ordering No.3 SEER/EER (Btuh) H x Wx L Supply Return (Ibs.) MCA* Fuse*
WSC – 208-230/1/60 – Single Phase – No Heat
3 WSC036E1R0A0000 13.0 37,650 32 x 44 x 70 18 x 15.5 24 x 14 589 31.2 45
4 WSC048E1R0A0000 13.0 49,040 32 x 44 x 70 18 x 15.5 24 x 14 600 38.9 60
5 WSC060E1R0A0000 13.0 58,360 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 44.6 70
WSC – 208-230/3/60 – Three Phase – No Heat
3 WSC036A3R0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 19.1 30
4 WSC048A3R0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 24.4 35
5 WSC060A3R0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 32.6 50
3 WSC036E3R0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 23.8 35
4 WSC048E3R0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 27.5 40
5 WSC060E3R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 30.2 45
6 WSC072A3R0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 32.2 50
71/2 WSC090A3R0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 41.4 60
10 WSC120A3R0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 50.4 60
WSC – 460/3/60 – Three Phase – No Heat
3 WSC036A4R0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 9.9 15
4 WSC048A4R0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 12.1 15
5 WSC060A4R0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 16.6 25
3 WSC036E4R0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 11.4 15
4 WSC048E4R0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 12.3 15
5 WSC060E4R0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 14.7 20
6 WSC072A4R0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 16.6 25
71/2 WSC090A4R0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 21.9 35
10 WSC120A4R0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 26.4 35
WSC – 575/3/60 – Three Phase – No Heat
3 WSC036AWR0A0000 10.2 38,100 32 x 44 x 70 18 x 15.5 24 x 14 534 8.3 15
4 WSC048AWR0A0000 10.7 50,800 32 x 44 x 70 18 x 15.5 24 x 14 566 10.1 15
5 WSC060AWR0A0000 10.1 62,100 32 x 44 x 70 18 x 15.5 24 x 14 584 13.1 20
3 WSC036EWR0A0000 13.0 38,030 32 x 44 x 70 18 x 15.5 24 x 14 589 8.8 15
4 WSC048EWR0A0000 13.0 50,130 32 x 44 x 70 18 x 15.5 24 x 14 600 9.5 15
5 WSC060EWR0A0000 13.0 63,440 41 x 53 x 89 33 x 17.5 32.13 x 17.5 825 11.0 15
6 WSC072AWR0A0000 10.6 72,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 12.5 15
71/2 WSC090AWR0A0000 10.1 92,000 41 x 53 x 89 33 x 17.5 32.13 x 17.5 937 16.8 25
10 WSC120AWR0A0000 10.1 119,000 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1084 21.0 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 HCAR breaker per NEC.
2 SEER applies, 3-5 tons; EER applies 6-10 tons.
3 Digit 7 - A=R-22, E=410A.

For complete equipment / combination


selections and installation instructions, please PH-25 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Heat Pump
Convertible 3-10 Tons
(Model Digit Numbers)
Digit Description Order Number Digit Description Order Number
1-8 Main Assembly (see previous page) 19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)
9 Unit Controls No Disconnect /Circuit Breaker/No Phase Monitor ...... 0
Unit Controls -ReliaTel™ Micro-processor .................. R Non-Fused Disconnect8 ........................................... 1
Circuit Breaker8 ....................................................... 2
10 (See Heater Table below) Phase Monitor0 ....................................................... 3
11 Minor Design Sequence Phase Monitor0 & Non-Fused Disconnect Switch ...... 4
First Sequence ........................................................ A Phase Monitor0 & Circuit Breaker ............................. 5
12-13 Service Sequence 20 Convenience Outlet
First Sequence (Factory Assiged) ............................ ✱,✱ No Convenience Outlet ............................................. 0
14 Fresh Air Selection Unpowered Convenience Outlet ............................... A
No Fresh Air ............................................................. 0 Powered Convenience Outlet (3 phase only)2 ............ B
0-50% Manual Outside Air Damper9 ......................... A 21 Communications Options
0-50% Motorized Outside Air Damper ........................ B No Communications Interface ................................... 0
0-100% Economizer, Dry Bulb without Trane Communications Interface ............................... 1
Barometric Relief 1 ............................................... C LonTalk® Communications Interface .......................... 2
0-100% Economizer, Dry Bulb with 22 Refrigeration System Option
Barometric Relief1 ............................................... D Standard Refrigeration System ................................. 0
0-100% Economizer, Reference Enthalpy
without Barometric Relief1 ..................................... E 23 Refrigeration Controls
0-100%Economizer, Reference Enthalpy No Refrigeration Control ........................................... 0
with Barometric Relief1 ......................................... F High Pressure Control5 ............................................ 1
0-100%Economizer, Comparative Enthalpy Frostat4 ................................................................... 2
without Barometric Relief 1 ................................... G Crankcase Heater .................................................... 3
0-100%Economizer, Comparative Enthalpy High Pressure Control5 and Frostat4 ........................ 4
with Barometric Relief 1 ......................................... H High Pressure Control5 and Crankcase Heater .......... 5
Frostat4 and Crankcase Heater5 ............................. 6
15 Supply Fan/Drive Type/Motor High Pressure Control5, Frostat4 and
Standard Drive ......................................................... 0 Crankcase Heater5 .............................................. 7
Oversized Motor ....................................................... 1
Optional Belt Drive Motor (3 phase only) .................... 2 24 Smoke Detector67
No Smoke Detector .................................................. 0
16 Hinged Service Access & Filters Return Air Smoke Detector ....................................... A
Standard Panels & Filters ......................................... 0 Supply Air Smoke Detector ....................................... B
Hinged Access Panels & Standard Filters .................. A Supply and Return Air Smoke Detectors .................... C
Standard Panels & 2" Pleated Filters ......................... B
Hinged Access Panels & 2" Pleated Filters ................ C 25 Monitoring Controls
No Monitoring Control ............................................... 0
17 Condenser Coil Protection Clogged Filter Switch ................................................ 1
Standard Coil ........................................................... 0 Fan Failure Switch .................................................... 2
Standard Coil with Hail Guard ................................... 1 Discharge Air Sensing Tube ...................................... 3
Epoxy Coated Condenser Coil .................................. 2 Clogged Filter Switch and Fan Fail Switch .................. 4
Epoxy Coated Condenser Coil with Hail Guard .......... 3 Clogged Filter Switch and Discharge
18 Through the Base Provisions Air Sensing Tube .................................................... 5
No Through the Base Provisions ............................... 0 Fan Fail Switch and Discharge Air Sensing Tube ......... 6
Through the Base Electric8 ...................................... A Clogged Filter and Fan Fail Switches
and Discharge Air Sensing Tube ............................. 7
1 Economizer with Barometric Relief is for downfllow configured units only. Order Economizer without conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power
Barometric Relief for horizontal configuration. Barometric relief for horizontal configured units must exhaust. Do not order the return air smoke detectors when using this type of accessory.
be ordered as field installed accessory BAYBARM010A. 8 Through the base electric required when ordering disconnect/circuit breaker options.
2 Requires use of Disconnect or Circuit Breaker. 9 The manual outside air damper will ship factory supplied within the unit, but must be field
3 Standard refrigeration metering device - short orifice. installed.
4 Frostat cannot be field installed in electro-mechanical units. 0 Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase Monitor will
5 High Pressure control is standard on 3 phase units with scroll compressor and WSC036A. be an option.
6 Not available with BAYFRST001A High Temperature Stat accessory.
7 The return air smoke detector may not fit up or work properly on the Convertible units when used in
Heaters (Digit 10)
kW Nominal No. kW Nominal No.
Rating Digit BTUH Stages Used With Rating Digit BTUH Stages Used With
208/240/1/60 460/3/60
3.8/5.0 (A) 12,800/17,100 1 WSC036-060A1 6.0 (B) 20,500 1 WSC036-060A4
7.5/10.0 (D) 25,600/34,100 2 WSC036-060A1 12.0 (E) 41,000 2 WSC036-060A4
10.4/13.8 (F) 35,300/47,100 2 WSC036-060A1 17.4 (G) 59,400 2 WSC036-060A4
13.2/17.6 (G) 45,100/60,100 2 WSC048-060A1 23.0 (J) 78,500 2 WSC060A4
208/240/3/60 9.0 (C) 30,700 1 W*C072-090A4
4.5/6.0 (B) 13,400/20,500 1 WSC036-060A3 18.0 (G) 61,400 1 W*C072-120A4
9.0/12.0 (E) 30,800/59,400 2 WSC036-060A3 27.0 (K) 92,100 2 W*C072-120A4
13.1/17.4 (G) 44,600/59,400 2 WSC036-060A3 36.0 (N) 122,900 2 W*C072-120A4
17.3/23.0 (J) 58,900/78,500 2 WSC060A3 54.0 (P) 184,300 2 W*C120A4
6.75/9.0 (C) 23,000/30,700 1 W*C072-090A3 575/3/60
13.5/18.0 (G) 46,100/61,400 1 W*C072-120A3 6.0 (B) 20,500 1 WSC036-060AW
20.3/27.0 (K) 69,000/92,100 2 W*C072-120A3 12.0 (E) 41,000 2 WSC036-060AW
27.0/36.0 (N) 92,200/122,900 2 W*C072-120A3 17.4 (G) 59,400 2 WSC036-060AW
40.5/54.0 (P) 138,200/184,300 2 W*C120A3 23.0 (J) 78,500 2 WSC060AW
9.0 (C) 30,700 1 W*C072-090AW
18.0 (G) 61,400 1 W*C072-120AW
27.0 (K) 92,100 2 W*C072-120AW
36.0 (N) 122,900 2 W*C072-120AW
54.0 (P) 184,300 2 W*C120AW
For complete equipment / combination
Effective 1/1/06 PH-26 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Heat Pump
Convertible 3-10 Tons

Table PH-27-A — Accessory Electric Heaters – Unit with heater is single circuit / single point power entry
Model Power kW Nominal No.
Number Supply Rating BTUH Stages 1
Used With1
BAYHTRR105A 208/240/1/60 3.8/5.0 12,800/17,100 1 WSC036-060(A or E)1
BAYHTRR110A 208/240/1/60 7.5/10.0 25,600/34,100 2 WS036-060(A or E)1
BAYHTRR114A 208/240/1/60 10.4/13.8 35,300/47,100 2 WSC036-060(A or E)1
BAYHTRR118A 208/240/1/60 13.2/17.6 45,100/60,100 2 WSC048-060(A or E)1
BAYHTRR306A 208/240/3/60 4.5/6.0 13,400/20,500 1 WSC036-060(A or E)3
BAYHTRR312A 208/240/3/60 9.0/12.0 30,800/41,000 2 WSC036-060(A or E)3
BAYHTRR318A 208/240/3/60 13.1/17.4 44,600/59,400 2 WSC036-060(A or E)3
BAYHTRR323A 208/240/3/60 17.3/23.0 58,900/78,500 2 WSC060(A or E)3
BAYHTRS309A 208/240/3/60 6.75/9.0 23,000/30,700 1 WSC072-090A3
BAYHTRS318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC072-090A3
BAYHTRS327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC072-090A3
BAYHTRS336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC072-090A3
BAYHTRT318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WSC120A3
BAYHTRT327A 208/240/3/60 20.3/27.0 69,000/92,100 2 WSC120A3
BAYHTRT336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WSC120A3
BAYHTRT354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WSC120A3

BAYHTRS409A 460/3/60 9.0 30,700 1 WSC072-090A4


BAYHTRS418A 460/3/60 18.0 61,400 1 WSC072-090A4
BAYHTRS427A 460/3/60 27.0 92,100 2 WSC072-090A4
BAYHTRS436A 460/3/60 36.0 122,900 2 WSC072-090A4
BAYHTRT418A 460/3/60 18.0 61,400 1 WSC120A4
BAYHTRT427A 460/3/60 27.0 92,100 2 WSC120A4
BAYHTRT436A 460/3/60 36.0 122,900 2 WSC120A4
BAYHTRT454A 460/3/60 54.0 184,300 2 WSC120A4
BAYHTRR406A 460/3/60 6.0 20,500 1 WSC036-060(A or E)4
BAYHTRR412A 460/3/60 12.0 41,000 2 WSC036-060(A or E)4
BAYHTRR418A 460/3/60 17.4 59,400 2 WSC036-060(A or E)4
BAYHTRR423A 460/3/60 23.0 78,500 2 WSC060(A or E)4

BAYHTRSW09A 575/3/60 9.0 30,700 1 WSC072-090AW


BAYHTRSW18A 575/3/60 18.0 61,400 1 WSC072-090AW
BAYHTRTW18A 575/3/60 18.0 61,400 1 WSC120AW
BAYHTRSW27A 575/3/60 27.0 92,100 2 WSC072-090AW
BAYHTRTW27A 575/3/60 27.0 92,100 2 WSC120AW
BAYHTRSW36A 575/3/60 36.0 122,900 2 WSC072-090AW
BAYHTRTW36A 575/3/60 36.0 122,900 2 WSC120AW
BAYHTRTW54A 575/3/60 54.0 184,300 2 WSC120AW
BAYHTRRW06A 575/3/60 6.0 20,500 1 WSC036-060(A or E)W
BAYHTRRW12A 575/3/60 12.0 41,000 2 WSC036-060(A or E)W
BAYHTRRW18A 575/3/60 17.4 59,400 2 WSC036-060(A or E)W
BAYHTRRW23A 575/3/60 23.0 78,500 2 WSC060(A or E)W
1 A = R-22, E = 410A

Table PH-27-B — Zone Sensors for ReliaTel™ Controlled Units


Model
Number Description 3
Used With3
BAYMTPL003B Retrofit Wall Cover Plate Kit 7.25" x 6.0" BAYSENS019C
BAYMTPL004B Retrofit Wall Cover Plate Kit 4.75" x 4.75" BAYSENS007B,009B,011B,013,014C,017B
BAYSENS007B Single Setpoint Manual Changeover WSC036-060(A or E)-120A
BAYSENS009B Dual Setpoint Manual or Auto Changeover WSC036-060(A or E)-120A
BAYSENS011B Dual Setpoint Man. or Auto Change-over with System
Function Lights WSC036-060(A or E)-120A
BAYSENS013C1 Room Sensor w/ Override and Cancel Buttons WSC036-060(A or E)-120A
BAYSENS014C1 Room Sensor w/ Temp. Adjustment with Override and
Cancel Buttons WSC036-060(A or E)-120A
BAYSENS017B Remote Room Sensor 010B, & 019C BAYSENS007B,009B,011B,019C
BAYSENS019C Programmable Night Setback w/System Function Lights WSC036-060(A or E)-120A
BAYSENS031A2 Digital Display Zone Sensor WSC036-060(A or E)-120A
BAYSENS032A2 Dual Thermistor Remote Zone Sensor WSC036-060(A or E)-120A
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.
2 Functional only with ReliaTel™ controls.
3 A=R-22, E=410A
For complete equipment / combination
selections and installation instructions, please PH-27 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Heat Pump
Convertible 3-10 Tons

Table PH-28-A — Accessories


Model Number Description r
Used Withr
BAYABRD001C ........................... ReliaTel™ Options Module ..................................................... See Note6
BAYBARM010A3 ....................... Barometric Relief .................................................................... WSC036-060(A or E)
BAYBARM011A3 ....................... Barometric Relief .................................................................... WSC072-120A
BAYCCHT010B ........................... Crankcase Heater .................................................................. WSC036-060(A or E), WSC072-120A1, A3
BAYCCHT011B ........................... Crankcase Heater .................................................................. WSC036-060(A or E), WSC072-120A1, A4, AW
BAYCCHT012A ........................... Crankcase Heater .................................................................. WSC090A3
BAYCCHT013A ........................... Crankcase Heater .................................................................. WSC090A4
BAYCCHT014A ........................... Crankcase Heater .................................................................. WSC090AW
BAYCO2K001Bw ........................ CO2 Sensor Kit, Wall Mounted ............................................... WSC036-060(A or E), WSC072-120A w/Economizer
2
BAYCO2K003Bw ........................ CO Sensor Kit, Duct Mounted .............................................. WSC036-060(A or E), WSC072-120A w/Economizer
BAYCURB042A4 ....................... Roof Curb ............................................................................... WSC036-060(A or E)
BAYCURB043A4 ....................... Roof Curb ............................................................................... WSC072-120A
BAYDFPS003A6 ........................ Clogged Filter Switch ............................................................. WSC036-060(A or E)-120A
BAYDFPS004A6 ........................ Fan Failure Switch .................................................................. WSC036-060(A or E)-120A
BAYDMPR051A .......................... 0-50% Motorized Outside Air Damper .................................... WSC036-060(A or E)
BAYDMPR053Be ....................... 0-50% Manual Outside Air Damper ........................................ WSC036-060(A or E)
BAYDMPR054A .......................... 0-50% Motorized Outside Air Damper .................................... WSC072-120A
BAYDMPR056Be ....................... 0-50% Manual Outside Air Damper ........................................ WSC072-120A
BAYECON085A ........................... 0-100% Economizer without Barometric Relief ....................... WSC036-060(A or E)
BAYECON087A ........................... 0-100% Economizer without Barometric Relief ....................... WSC072-120A
BAYENTH005A1 ........................ Reference Enthalpy Kit ........................................................... BAYECON085A,087A
BAYENTH006B1 ........................ Comparative Enthalpy Kit ....................................................... BAYECON085A,087A
BAYFRST001A7 ........................ High Temperature Stat ............................................................ WSC036-060(A or E), WSC072-120A
BAYGARD036B ........................... Condenser Coil Hail Guard ..................................................... WSC036-060(A or E)
BAYGARD040B ........................... Condenser Coil Hail Guard ..................................................... WSC072-090A
BAYGARD041B ........................... Condenser Coil Hail Guard ..................................................... WSC120A
BAYHSDR012A ........................... High Static Drive Kit ............................................................... WSC072A
BAYHSMT073A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)1,(A or E)3
BAYHSMT074A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)4
BAYHSMT075A ........................... .45 HP Direct Drive Oversized Motor Kit ................................. WSC036(A or E)W
BAYHSMT076A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)1,(A or E)3
BAYHSMT077A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)4
BAYHSMT078A ........................... .75 HP Direct Drive Oversized Motor Kit ................................. WSC048(A or E)W
BAYHSMT079A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)1,(A or E)3
BAYHSMT080A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)4
BAYHSMT081A ........................... 1.2 HP Direct Drive Oversized Motor Kit ................................. WSC060(A or E)W
BAYHSMT082A ........................... 2 HP Belt Drive Oversized Motor ............................................ WSC072A3, A4
BAYHSMT083A ........................... 2 HP Belt Drive Oversized Motor ............................................ WSC072AW
BAYHSMT086A ........................... 3 HP Belt Drive Oversized Motor ............................................ WSC090A3, A4
BAYHSMT087A ........................... 3 HP Belt Drive Oversized Motor ............................................ WSC090AW
BAYHSMT090A ........................... 5 HP Belt Drive Oversized Motor ............................................ WSC120A3, A4
BAYHSMT091A ........................... 5 HP Belt Drive Oversized Motor ............................................ WSC120AW
BAYICSI003A8 ........................... Trane Communications Interface ............................................ WSC036-060(A or E), WSC072-120A
BAYKSKT255A ............................ Quick Start Kit ........................................................................ WSC048,060(A or E)A1
BAYKSKT256A ............................ Quick Start Kit ........................................................................ WSC036(A or E)1
BAYLOAM020B6 ....................... Evaporator Defrost Control (Frostat) ....................................... WSC036-060(A or E), WSC072-120A
BAYLTCI002B0 .......................... LonTalk® Communications Interface ...................................... WSC036-060(A or E), WSC072-120A
BAYPWRX026A9 ....................... Power Exhaust ....................................................................... WSC072-120A3
BAYPWRX027A9 ....................... Power Exhaust ....................................................................... WSC072-120A4
BAYPWRX028A9 ....................... Power Exhaust ....................................................................... WSC072-120AW
BAYQACB009A45 .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E)
BAYQACB010A45 .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E)
BAYQACB011A4q .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E), WSC072-120A
BAYQACB012A4q .................... Quick Adapt Roof Curb ........................................................... WSC036-060(A or E), WSC072-120A
BAYSENS016A ........................... Temperature Sensor ............................................................... WSC036-060(A or E)
BAYSERV001A ........................... Selective Resistance Service Tester ....................................... WSC036-060(A or E), WSC072-120A
BAYSTAT023 ............................... Remote Potentiometer ............................................................ BAYECON085A,087A
BAYTUBE005A26 ..................... Discharge Air Sensing Kit ....................................................... WSC036-060(A or E)
BAYTUBE007 .............................. Discharge Air Sensing Kit ....................................................... WSC072-120A
BAYVNOR001Bw6 .................... Ventilation Override Kit w/ReliaTel™ options module .............. WSC036-060(A or E), WSC072-120A
1 Kits contain all necessary parts to achieve desired level of enthalpy control.
2 Used for true discharge air sensing in both heating and cooling. Required for supply air tempering.
3 Barometric Relief accessory installs in ductwork for horizontal configuration. For downflow configuration, installs in the unit's horizontal return duct. See Installer's Guide for complete
instructions.
4 Lynn Haven manufacturing has a no return policy for this roof curb.
5 BAYQACB009A adapts Voyager BAYCURB021A roof curb to accept Precedent 3-5 ton unit. BAYQACB010A adapts Voyager (BAYCURB022A roof curb to accept Precedent 3-5 ton unit.
6 BAYABRD001C is required when ordering field installed accessories Clogged Filter Switch (BAYDFPS003A), Fan Fail Switch (BAYDFPS004A), Discharge Air Sensing Kit BAYTUBE004A
or BAYTUBE005A) or Evaporator Defrost Control (Frostat) (BAYLOAM020B) Ventilation Override Kit (BAYVNOR001B) unless the following options are factory installed: Frostat, Smoke
Detector, Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing Kit. These factory installed options Include the ReliaTel™ Options Module.
7 Cannot be used in conjunction with factory installed smoke detector.
8 Interface allows unit to communicate with Tracer 100, Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.
9 Power Exhaust cannot be used with Barometric Relief. Order Economizer without Barometric Relief.
0 Interface allows unit to communicate as a Trane LonTalk device or directly with generic LonTalk Network BAS Controls.
q BAYQACB012A adapts Voyager BAYCURB025 roof curb to accept Convertible 6-10 ton unit.BAYQACB011A adapts Voyager BAYCURB022B roof curb to accept Precedent 6-10 ton unit.
w Field installed accessory. Requires an economizer.
e The manual outside air damper will ship factory supplied within the unit, but must be field installed.
r A=R-22, E=410A.

For complete equipment / combination


Effective 1/1/06 PH-28 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Light Commercial Packaged Heat
Pump New Model Quick Reference

Table PH-29-A — Quick Reference


Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
WCH036B100A WCD036C100B Microprocessor WSC036*1R0A0000 WSC036*1R0A**000000000000
WCH036B300A WCD036C300B Microprocessor WSC036*3R0A0000 WSC036*3R0A**000000000000
WCH036B400A WCD036C400B Microprocessor WSC036*4R0A0000 WSC036*4R0A**000000000000
WCH048C100B WCD048C100B Microprocessor WSC048*1R0A0000 WSC048*1R0A**000000000000
WCH048C300B WCD048C300B Microprocessor WSC048*3R0A0000 WSC048*3R0A**000000000000
WCH048C400B WCD048C400B Microprocessor WSC048*4R0A0000 WSC048*4R0A**000000000000
WCH048CW00B WCD048CW00B Microprocessor WSC048*WR0A0000 WSC048*WR0A**000000000000
WCH060C100B WCD060C100B Microprocessor WSC060*1R0A0000 WSC060*1R0A**000000000000
WCH060C300B WCD060C300B Microprocessor WSC060*3R0A0000 WSC060*3R0A**000000000000
WCH060C400B WCD060C400B Microprocessor WSC060*4R0A0000 WSC060*4R0A**000000000000
WCH060CW00B WCD060CW00B Microprocessor WSC060*WR0A0000 WSC060*WR0A**000000000000
WCH075C300B WCD075C300B Microprocessor WSC072A3R0A0000 WSC072A3R0A**000000000000
WCH075C400B WCD075C400B Microprocessor WSC072A4R0A0000 WSC072A4R0A**000000000000
WCH075CW00B WCD075CW00B Microprocessor WSC072AWR0A0000 WSC072AWR0A**000000000000
WCH090C300B WCD090C300B Microprocessor WSC090A3R0A0000 WSC090A3R0A**000000000000
WCH090C400B WCD090C400B Microprocessor WSC090A4R0A0000 WSC090A4R0A**000000000000
WCH090CW00B WCD090CW00B Microprocessor WSC090AWR0A0000 WSC090AWR0A**000000000000
WCH120B300E WCD120B300E Microprocessor WSC120A3R0A0000 WSC120A3R0A**000000000000
WCH120B400E WCD120B400E Microprocessor WSC120A4R0A0000 WSC120A4R0A**000000000000
WCH120BW00E WCD120BW00E Microprocessor WSC120AWR0A0000 WSC120AWR0A**000000000000
* Digit 7- A=R-22, E=410A.
For additional Controls Information:
See ReliaTel™ and Micro Control features on PC-35 and PC-36.

For complete equipment / combination


selections and installation instructions, please PH-29 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Heat Pump with ReliaTel™
Controls 12½ through 20 Tons
• EER up to 10.0 • Single point power for electric heat
• ReliaTel™ processor control features are • Complete line of optional electric heaters
listed on page PC-35 • Internally enhanced coil tubing
• Built-in anti-short cycle, time-delay relay • Low ambient to 0°F standard
and minimum on time controls • Colored and numbered wiring
• 2" filters for 12½ - 20 ton units • Common cabinet and accessories as
• Liquid line drier TCD/TCH and YCD/YCH models
• Built-in fork lift holes • Quick-adjust idler arm pulley.
• Operating charge of R-22 • 5-year limited compressor warranty
12½ – 20 Ton • “Quick-Sess” service panels slide in (12½ – 15 tons)
WCD/WCH—Downflow/Horizontal and out • 1-year limited parts warranty
• Scroll compressors • 1-year limited compressor warranty (20
• Dedicated horizontal and downflow designs tons)
• Single-side access

Table PH-30-A — WCD Downflow or WCH Horizontal — Micro Control Unit


Unit Power Supply Performance Cooling Dimensions (in.) Shipping Max Fuse Size or55 Downflow
Tons Model No. Volts/Phase/Hz EER (1Ø) Capacity (Btuh) H x W x L Weight (Ibs.) 3
MCA3 Max Circuit Breaker Roofcurb
121/2 WCD150B300G 208-230/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 66 80 BAYCURB026B
15 WCD180B300H 208-230/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 76 90 BAYCURB026B
20 WCD240B300G 208-230/3/60 10.0 244,00 54 x 855/16 x 1225/16 2467 96 125 BAYCURB027B
121/2 WCD150B400G 460/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 31 40 BAYCURB026B
15 WCD180B400H 460/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 39 45 BAYCURB026B
20 WCD240B400G 460/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 49 60 BAYCURB027B
121/2 WCD150BW00G 575/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 25 30 BAYCURB026B
15 WCD180BW00H 575/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 31 35 BAYCURB026B
20 WCD240BW00G 575/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 38 45 BAYCURB027B
121/2 WCH150B300G 208-230/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 66 80 BAYCURB026B
15 WCH180B300H 208-230/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 76 90 BAYCURB026B
20 WCH240B300G 208-230/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 96 125 BAYCURB027B
121/2 WCH150B400G 460/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 31 40 BAYCURB026B
15 WCH180B400H 460/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 39 45 BAYCURB026B
20 WCH240B400G 460/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 49 60 BAYCURB027B
121/2 WCH150BW00G 575/3/60 9.50 152,000 501/8 x 715/16 x 1075/16 1719 25 30 BAYCURB026B
15 WCH180BW00H 575/3/60 9.60 180,000 501/8 x 715/16 x 1075/16 1857 31 35 BAYCURB026B
20 WCH240BW00G 575/3/60 10.0 244,000 54 x 855/16 x 1225/16 2467 38 45 BAYCURB027B

Supply Supply Return Return Curb Size Roof Opening


Tons 12
Downflow W x L12 12
Horizontal H x W12 12
Downflow W x L12 12
Horizontal H x W12 H x W x L2424 12
W x L12
121/2 – 15 289/16 x 551/2 421/2 x 261/2 207/8 x 63 421/2 x 249/16 141/16 x 6615/16 x 1021/4 621/2 x 731/2
20 289/16 x 691/2 467/16 x 261/2 221/4 x 77 467/16 x 279/16 141/16 x 8015/16 x 1171/8 761/2 x 81

For complete equipment / combination


Effective 1/1/06 PH-30 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Heat Pump with ReliaTel™
Controls 12½ through 20 Tons
Table PC-31-A — Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPS
section of this book.
Digit Description Order Number Used With
1-8 Main Assembly (see previous page)
9-10 Factory Installed Options
No Options 00 WC*150-240
Downflow Economizer3 0A WCD150-240
Oversized Motor 0B WC*150-240
Downflow Economizer and Oversized Motor3 0C WCD150-240
Trane Communications Interface (TCI)4 0F WC*150-240
Downflow Economizer TCI34 0G WCD150-240
11-12 Minor Design and Service Sequence **
1 Price includes accessory and factory installation.
2 Four (4) week shipping approximately.
3 Some field set up required.
4 TCI is for use with non-VariTrac systems and VariTrac systems.

Table PH-31-B — Zone Sensors


Model Number Description Used With
BAYSENS007B ............ Single Setpoint Manual Changeover with Emergency Heat ........................... WC*150-240
BAYSENS009B ............ Dual Setpoint Manual or Automatic Changeover with Emergency Heat .......... WC*150-240
BAYSENS011B ............ Dual Setpoint Manual or Automatic Changeover with System ........................ WC*150-240
Function Light and Emergency Heat
BAYSENS013C1 ........ Room Sensor with Override Button ............................................................. WC*150-240
BAYSENS014C1 ........ Room Sensor with Temperature Adjustment ................................................ WC*150-240
BAYSENS019C ............ Programmable Night Setback ..................................................................... WC*150-240
BAYSENS017B ............ Remote Room Sensor ............................................................................... BAYSENS007B, 009B, 011B, 019C
BAYSENS031Aq ......... Digital Display Zone Sensor ....................................................................... WC*150-240
BAYSENS032Aq ......... Dual Thermistor Remote Zone Sensor ....................................................... WC*150-240
BAYMTPL003B ............ Retrofit Wall Cover Plate Kit (71/4" x 6") ......................................................... BAYSENS019C
BAYMTPL004A .............. Retrofit Wall Cover Plate Kit (41/4" x 41/4") .......................................................... BAYSENS007B, 009B, 011B, 017B,
013C, 014C

For complete equipment / combination


selections and installation instructions, please PH-31 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged Heat Pump with
ReliaTel™ Controls 12½ through 20
Tons Accessories
Table PH-32-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of this
book.
Model Number Description Used With
BAYABRD002Bq ........... ReliaTel™ Options Module .......................................... WCH/D150-240
BAYCO2K002Bw ........... CO2 Sensor Wall Mounted ........................................... WC*150-240 w/Economizer
BAYCO2K004Bw ........... CO2 Sensor Duct Mounted .......................................... WC*150-240 w/Economizer
BAYCURB026B89 ........ Downflow Only Roof Curb ............................................ WCD150B, 180B
BAYCURB027B89 ........ Downflow Only Roof Curb ............................................ WCD240B
BAYECON089Aq ........... Downflow Economizer with Barometric Relief ................ WCD150B, 180B
BAYECON090Aq ........... Downflow Economizer with Barometric Relief ................ WCD240B
BAYECON091A .............. Horizontal Economizer ................................................. WCH150B, 180B
BAYECON092A .............. Horizontal Economizer ................................................. WCH240B
BAYFRST003A .............. High Temperature Stat ................................................ WC*150-240 w/ICS
BAYENTH007A .............. Reference Enthalpy Kit ................................................ All BAYECON089-92A
BAYENTH008A .............. Comparative Enthalpy Kit ............................................ All BAYECON089-92A
BAYDMPR029C ............. 0-25% Manual Outside Air Damper ............................... WCD/WCH (12½-20 Tons)
BAYDMPR0057A ............ 0-50% Motorized Outside Air Damper ........................... WCD/WCH150B, 180B
BAYDMPR058A ............. 0-50% Motorized Outside Air Damper ........................... WCD/WCH240B
BAYDFPS005A0q ......... Clogged Filter Switch ................................................... WCD/WCH (12½-20 Tons)
BAYDFPS006A0q ......... Fan Failure Switch ....................................................... Economizers/0-50% Motorized Air Dampers
BAYGARD043Bq ........... Tool-less Hail Guard .................................................... WC*150B
BAYGARD044Bq ........... Tool-less Hail Guard .................................................... WC*180B
BAYGARD045Aq ........... Tool-less Hail Guard .................................................... WC*240B
BAYPWRX029A ............. Power Exhaust for 230 volt units ................................... BAYECON089,090 (WCD150B, 180B, 240B3)
BAYPWRX030A ............. Power Exhaust for 460 volt units ................................... BAYECON089,090 (WCD150B, 180B, 240B4)
BAYPWRX031A ............. Power Exhaust for ....................................................... WCD150,180,240BW
BAYHSDR002B6 .......... High Static Drive .......................................................... WCD/WCH150B
BAYHSMT039B6q ........ 5HP Oversized Motor Kit .............................................. WCD/WCH150B, 180B
BAYHSMT040B6q ........ 5HP Oversized Motor Kit .............................................. WC*150, 180BW
BAYHSMT042A .............. 7-1/2HP Oversized Motor Kit ........................................ WC*240BW
BAYHSMT098A6q ........ 7-1/2HP Oversized Motor Kit ........................................ WC*240B3
BAYHSMT099A6q ......... 7-1/2HP Oversized Motor Kit ........................................ WC*240B4
BAYICSI004Ber ............ Trane Communications Interface, Comm 3/4 (TCI) ......... WC*150-300
BAYLOAM023A0q ......... Evaporator Deforst Control (Frostat) .............................. WC*150-240
BAYLTCI003Br .............. LonTalk® Communications Inteface (LCI) ....................... WC*150-300
BAYSERV001A .............. Selective Resistance Service Tester .............................. WCD/WCH (12½-20 Tons)
BAYSTAT023 ................. Remote Potentiometer ................................................ All BAYECON089-92A
BAYSENS016A .............. Temperature Sensor .................................................... WCD/WCH (12½-20 Tons)
BAYTUBE008A70q ....... Discharge Air Sensing Kit ............................................. WCD150-240
BAYTUBE009A70q ....... Discharge Air Sensing Kit ............................................. WCH150-240
BAYVNOR002B0 ......... Ventilation Override Kit ............................................. WCH150-240 w/ReliaTel™ Options Module
1 Dimensions are in inches.
2 Interior Dimension.
3 MCA = Minimum Circuit Ampacity.
4 Measurement Includes Curb Flange.
5 HACR Type Circuit per NEC.
6 High static drive and oversized motors are mutually exclusive, Do not Combine.
7 Used for true discharge air sensing in both heating and cooling models.
8 Clarksville Manufacturing has a no-return policy for this roof curb.
9 For downflow use only. Can not be adapted for horizontal units.
0 BAYABRD002B is required when ordering field installed accessories BAYDFPS005A or 006A, BAYTUBE008A or 009A and BAYLOAM023A or BAYVNOR002B.
q Field or factory installed option.
w Field installed accessory. Requires an economizer.
e Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100, Tracker, VariTrac II, and is the prefered method of communication to Tracer Summit.
r With ReliaTel™ controlled units only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 PH-32 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Heat Pump with Micro
Controls 12½ through 20 Tons
Table PH-33-A — Downflow/Horizontal Supplementary Heaters:
Model Power kW Nominal No.
Number Supply Rating BTUH Stages Used With
AYDHTRK418A 460/3/60 18.0 61,400 1 WCD150B4,180B4
AYDHTRK436A 460/3/60 36.0 122,900 2 WCD150B4,180B4
AYDHTRK454A 460/3/60 54.0 184,300 2 WCD150B4,180B4

AYDHTRK318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WCD150B3, 180B3


AYDHTRK336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCD150B3, 180B3
AYDHTRK354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCD150B3, 180B3

AYDHTRL336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCD240B3


AYDHTRL354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCD240B3
AYDHTRK372A 208/240/3/60 54.0/72.0 184,300/245,700 2 WCD240B3

AYDHTRL436A 460/3/60 36.0 122,900 2 WCD240B4


AYDHTRL454A 460/3/60 54.0 184,300 2 WCD240B4
AYDHTRK472A 460/3/60 72.0 245,700 2 WCD240B4

AYHHTRN318A 208/240/3/60 13.5/18.0 46,100/61,400 1 WCH150B3, 180B3


AYHHTRP336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCH150B3, 180B3
AYHHTRP354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCH150B3, 180B3

AYHHTRP418A 460/3/60 18.0 61,400 1 WCH180B4,150B4


AYHHTRP436A 460/3/60 36.0 122,900 2 WCH180B4,150B4
AYHHTRP454A 460/3/60 54.0 184,300 2 WCH180B4,150B4

AYHHTRN336A 208/240/3/60 27.0/36.0 92,200/122,900 2 WCH240B3


AYHHTRN354A 208/240/3/60 40.5/54.0 138,200/184,300 2 WCH240B3
AYHHTRN372A 208/240/3/60 54.0/72.0 184,300/245,700 2 WCH240B3

AYHHTRN436A 460/3/60 36.0 122,900 2 WCH240B4


AYHHTRN454A 460/3/60 54.0 184,300 2 WCH240B4
AYHHTRN472A 460/3/60 72.0 245,700 2 WCH240B4

AYDHTRKW18A 575/3/60 18.0 61,400 1 WCD120BW,180BW


AYDHTRKW36A 575/3/60 36.0 122,900 2 WCD120BW,180BW
AYDHTRKW54A 575/3/60 54.0 184,300 2 WCD120BW,180BW

AYDHTRLW36A 575/3/60 36.0 122,900 2 WCD240BW


AYDHTRLW54A 575/3/60 54.0 184,300 2 WCD240BW
AYDHTRKW72A 575/3/60 72.0 245,700 2 WCD240BW

AYHHTRNW18A 575/3/60 18.0 61,400 1 WCH150BW,180BW


AYHHTRPW36A 575/3/60 36.0 122,900 2 WCH150BW,180BW
AYHHTRPW54A 575/3/60 54.0 184,300 2 WCH150BW,180BW

AYHHTRNW36A 575/3/60 36.0 122,900 2 WCH240BW


AYHHTRNW54A 575/3/60 54.0 184,300 2 WCH240BW
AYHHTRNW72A 575/3/60 72.0 245,700 2 WCH240BW
Note: Unit with heater is single circuit/single point.
See ReliaTel™ and Micro Control features on PC-35 and PC-36.

For complete equipment / combination


selections and installation instructions, please PH-33 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 2 through 5 Tons

• Ultra quiet operation provides best-in-class • Complete set of customized electric


performance with barely noticeable sound heaters designed for all models. Features
levels. a polarized plug for easy installation.
• Appliance grade finish of durable powder • Optional filter rack kits fit inside the unit.
paint baked on both sides of the panels. Available for 1" or 2" media.
• Exclusive Climatuff® high efficiency • Non-bleed expansion valves on indoor
compressor with internal overload protection. and outdoor coils.
• Aerospace ducted outdoor fan with a high • Direct drive 2 and 3 speed indoor blower
efficiency motor for quiet and reliable motors.
operation. • Pressure taps easily accessed and
• Composite Vortica® blower provides better protected inside compressor compart-
airflow and less sound while using less ment.
energy. • Easy access liquid line tap inside
• Spine Fin™ outdoor coil for long lasting compressor compartment.
performance and durability. • Standard operation to 55°F as manufac-
• Right side electrical service for high and low tured.
voltage lines. • Low ambient cooling to 0°F with kit.
• Architecturally integrated louvers and • Rugged steel basepan features deep drawn • UL approved and listed.
corner guards deliver durable protection, duct connections and emergency drains. • 20 year heat exchanger, 10 year
extra safety, and great looks. • Steeply sloped composite drainpan will compressor, 10 year outdoor coil, and
• Weather Beater Top contoured for great empty fast and never rust. 5 year other parts limited warranty.
appearance and reinforced for strength. • Ships in horizontal configuration and (Residential Use Only)
converts quickly for downflow. • Optional extended warranty.

Table PG-1-A — 2YCX- XL13c - Convertible Package Gas/Electric - R-22


Cabinet
Model AFUE (%) Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
2YCX – 208/230/1/60
2YCX3024A1040A 25,500 13.35/11.65 80 470 13.3 20 70 36 x 51 x 43
2YCX3024A1064A 25,500 13.35/11.65 80 481 13.3 20 70 36 x 51 x 43
2YCX3030A1040A 29,400 13.20/11.30 80 470 16.3 25 70 36 x 51 x 43
2YCX3030A1064A 29,400 13.20/11.30 80 481 16.3 25 70 36 x 51 x 43
2YCX3030A1075A 29,400 13.20/11.30 80 481 16.3 25 70 36 x 51 x 43
2YCX3036A1063A 35,200 13.00/11.20 80 479 23.0 35 72 36 x 51 x 43
2YCX3036A1075A 35,200 13.00/11.20 80 479 23.0 35 72 36 x 51 x 43
2YCX3036A1096A 35,200 13.00/11.20 80 485 23.0 35 72 36 x 51 x 43
2YCX3042A1064A 41,500 13.15/11.30 80 599 24.5 40 73 38 x 61 x 46
2YCX3042A1075A 41,500 13.15/11.30 80 599 24.5 40 73 38 x 61 x 46
2YCX3042A1096A 41,500 13.15/11.30 80 607 24.5 40 73 38 x 61 x 46
2YCX3048A1075A 48,000 13.30/11.25 80 656 29.0 45 73 38 x 61 x 46
2YCX3048A1096A 48,000 13.30/11.25 80 663 29.0 45 73 38 x 61 x 46
2YCX3048A1120A 48,000 13.30/11.25 80 669 29.0 45 73 38 x 61 x 46
2YCX3060A1096A 59,500 13.55/11.60 80 678 40.4 60 75 42 x 61 x 46
2YCX3060A1120A 59,500 13.55/11.60 80 684 40.4 60 75 42 x 61 x 46

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PG-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

• Appliance grade finish of durable powder • Complete set of customized electric


paint baked on both sides of the panels. heaters designed for all models. Features
• Exclusive Climatuff® high efficiency a polarized plug for easy installation.
compressor with internal overload • Optional filter rack kits fit inside the unit.
protection. Available for 1" or 2" media.
• Aerospace ducted outdoor fan with a high • Non-bleed expansion valves on indoor
efficiency motor for quiet and reliable and outdoor coils.
operation. • Direct drive 2 and 3 speed indoor blower
• Composite Vortica® blower provides motors.
better airflow and less sound while using • Pressure taps easily accessed and
less energy. protected inside compressor compart-
• Spine Fin™ outdoor coil for long lasting ment.
performance and durability. • Easy access liquid line tap inside
• Right side electrical service for high and compressor compartment.
low voltage lines. • Standard operation to 55°F as manufac-
• Rugged steel basepan features deep tured.
drawn duct connections and emergency • Low ambient cooling to 0°F with kit.
• Architecturally integrated louvers and drains. • UL approved and listed.
corner guards deliver durable protection, • Steeply sloped composite drainpan will • 20 year heat exchanger, 10 year
extra safety, and great looks. empty fast and never rust. compressor, 10 year outdoor coil, and
• Ultra quiet operation provides best-in-class • Ships in horizontal configuration and 5 year other parts limited warranty.
performance with barely noticeable sound converts quickly for downflow. (Residential Use Only)
levels. • Optional extended warranty.

Table PG-2-A — 4YCX - XL13c - Convertible Package Gas/Electric - R-410A


Cabinet
Model AFUE (%) Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
4YCX – 208/230/1/60
4YCX3018A1040A 18,800 13.55/11.15 80 471 10.1 15 69 36 x 51 x 43
4YCX3036A1064A 36,400 13.15/11.05 80 488 23.6 35 71 36 x 51 x 43
4YCX3036A1075A 36,400 13.15/11.05 80 488 23.6 35 71 36 x 51 x 43
4YCX3036A1096A 36,400 13.15/11.05 80 493 23.6 35 71 36 x 51 x 43
4YCX3048A1075A 46,500 13.05/11.00 80 645 31.5 50 73 38 x 61 x 46
4YCX3048A1096A 46,500 13.05/11.00 80 653 31.5 50 73 38 x 61 x 46
4YCX3048A1120A 46,500 13.05/11.00 80 659 31.5 50 73 38 x 61 x 46
4YCX3060A1096A 60,000 13.40/10.95 80 678 43.3 60 75 40 x 61 x 46
4YCX3060A1120A 60,000 13.40/10.95 80 684 43.3 60 75 40 x 61 x 46
4YCX – 208/230/3/60
4YCX3036A3064A 36,400 13.15/11.05 80 488 18.5 30 71 36 x 51 x 43
4YCX3036A3075A 36,400 13.15/11.05 80 488 18.5 30 71 36 x 51 x 43
4YCX3036A3096A 36,400 13.15/11.05 80 493 18.5 30 71 36 x 51 x 43
4YCX3048A3075A 46,500 13.05/11.00 80 645 24.0 35 73 38 x 61 x 46
4YCX3048A3096A 46,500 13.05/11.00 80 653 24.0 35 73 38 x 61 x 46
4YCX3048A3120A 46,500 13.05/11.00 80 659 24.0 35 73 38 x 61 x 46
4YCX3060A3096A 60,000 13.40/10.95 80 678 31.5 50 75 40 x 61 x 46
4YCX3060A3120A 60,000 13.40/10.95 80 684 31.5 50 75 40 x 61 x 46
4YCX – 460/3/60
4YCX3036A4064A 36,400 13.15/11.05 80 448 8.7 15 71 36 x 51 x 43
4YCX3036A4075A 36,400 13.15/11.05 80 448 8.7 15 71 36 x 51 x 43
4YCX3036A4096A 36,400 13.15/11.05 80 493 8.7 15 71 36 x 51 x 43
4YCX3048A4075A 46,500 13.05/11.00 80 645 11.7 15 73 38 x 61 x 46
4YCX3048A4096A 46,500 13.05/11.00 80 653 11.7 15 73 38 x 61 x 46
4YCX3048A4120A 46,500 13.05/11.00 80 659 11.7 15 73 38 x 61 x 46
4YCX3060A4096A 60,000 13.40/10.95 80 678 19.3 25 75 40 x 61 x 46
4YCX3060A4120A 60,000 13.40/10.95 80 684 19.3 25 75 40 x 61 x 46
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCX3018A through 2/4YCX3036A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PG-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCX3018A through 2/4YCX3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCX3042A through 2/4YCX3060A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PG-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCX3042A through 2/4YCX3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 2 through 5 Tons

• Weather Beater Top contoured for great • Complete set of customized electric
appearance and reinforced for strength. heaters designed for all models. Features
• Appliance grade finish of durable powder a polarized plug for easy installation.
paint baked on both sides of the panels. • Optional filter rack kits fit inside the unit.
• Exclusive Climatuff® high efficiency Available for 1" or 2" media.
compressor with internal overload • Non-bleed expansion valves on indoor
protection. and outdoor coils.
• High efficiency outdoor fan motor for quiet • Direct drive 2 and 3 speed indoor blower
and reliable operation. motors.
• Composite Vortica® blower provides • Pressure taps easily accessed and
better airflow and less sound while using protected inside compressor compart-
less energy. ment.
• Spine Fin™ outdoor coil for long lasting • Easy access liquid line tap inside
performance and durability. compressor compartment.
• Right side electrical service for high and • Standard operation to 55°F as manufac-
low voltage lines. tured.
• Rugged steel basepan features deep • Low ambient cooling to 0°F with kit.
• All steel louvers and cabinet for rugged, drawn duct connections and emergency • UL approved and listed.
long lasting protection. drains. • 10 year heat exchanger, 5 year
• Stainless steel burners and heat exchanger • Steeply sloped composite drainpan will compressor and coil and 5 year other
for extra long life and safety. empty fast and never rust. parts limited warranty.
• Quiet operation delivers great in-home • Ships in horizontal configuration and (Residential Use Only)
comfort with minimal sound. converts quickly for downflow. • Optional extended warranty.
Table PG-7-A — 2YCC - XB13c - Convertible Package Gas/Electric - R-22
Cabinet
Model AFUE (%) Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
2YCC – 208/230/1/60
2YCC3024A1040A 23,000 13.00/11.00 80 470 13.3 20 74 36 x 49 x 41
2YCC3024A1064A 23,000 13.00/11.00 80 481 13.3 20 74 36 x 49 x 41
2YCC3030A1040A 28,000 13.00/11.00 80 470 16.3 25 74 36 x 49 x 41
2YCC3030A1064A 28,000 13.00/11.00 80 481 16.3 25 74 36 x 49 x 41
2YCC3030A1075A 28,000 13.00/11.00 79.4 481 16.3 25 74 36 x 49 x 41
2YCC3036A1064A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 41
2YCC3036A1075A 35,000 13.00/11.00 80 479 23.0 35 76 36 x 49 x 41
2YCC3036A1096A 35,000 13.00/11.00 80 485 23.0 35 76 36 x 49 x 41
2YCC3042A1064A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 44
2YCC3042A1075A 40,000 13.00/11.00 80 599 24.5 40 78 38 x 59 x 44
2YCC3042A1096A 40,000 12.20/11.00 80 607 24.5 40 78 38 x 59 x 44
2YCC3048A1075A 47,000 13.00/11.00 80 656 29.0 45 77 38 x 59 x 44
2YCC3048A1096A 47,000 13.00/11.00 80 663 29.0 45 77 38 x 59 x 44
2YCC3048A1120A 47,000 13.00/11.00 80 669 29.0 45 77 38 x 59 x 44
2YCC3060A1096A 58,000 13.00/11.00 80 678 40.4 60 76 42 x 59 x 44
2YCC3060A1120A 58,000 13.00/11.00 80 684 40.4 60 76 42 x 59 x 44

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PG-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

• Weather Beater Top contoured for great • Complete set of customized electric
appearance and reinforced for strength. heaters designed for all models.
• Appliance grade finish of durable powder Features a polarized plug for easy
paint baked on both sides of the panels. installation.
• Exclusive Climatuff® high efficiency • Optional filter rack kits fit inside the unit.
compressor with internal overload Available for 1" or 2" media.
protection. • Non-bleed expansion valves on indoor
• High efficiency outdoor fan motor for quiet and outdoor coils.
and reliable operation. • Direct drive 2 and 3 speed indoor blower
• Composite Vortica® blower provides motors.
better airflow and less sound while using • Pressure taps easily accessed and
less energy. protected inside compressor compart-
• Spine Fin™ outdoor coil for long lasting ment.
performance and durability. • Easy access liquid line tap inside
• Right side electrical service for high and compressor compartment.
low voltage lines. • Standard operation to 55°F as manufac-
• Rugged steel basepan features deep tured.
• All steel louvers and cabinet for rugged, drawn duct connections and emergency • Low ambient cooling to 0°F with kit.
long lasting protection. drains. • UL approved and listed.
• Stainless steel burners and heat exchanger • Steeply sloped composite drainpan will • 10 year heat exchanger, 5 year
for extra long life and safety. empty fast and never rust. compressor and coil and 5 year other
• Quiet operation delivers great in-home • Ships in horizontal configuration and parts limited warranty.
comfort with minimal sound. converts quickly for downflow. (Residential Use Only)
• Optional extended warranty.
Table PG-8-A — 4YCC - XB13c - Convertible Package Gas/Electric - R-410A
Cabinet
Model AFUE (%) Shipping Max Sound Dimensions (in.)
Number Capacity SEER/EER HSPF Weight MCA Fuse Rating H xW x L
4YCC – 208/230/1/60
4YCC3018A1040A 18,000 13.00/11.00 79.8 471 10.1 15 74 36 x 49 x 41
4YCC3036A1064A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 41
4YCC3036A1075A 35,000 13.00/11.00 80 488 23.6 35 75 36 x 49 x 41
4YCC3036A1096A 35,000 13.00/11.00 80 493 23.6 35 75 36 x 49 x 41
4YCC3048A1075A 46,500 13.00/11.00 80 645 31.5 50 80 38 x 59 x 44
4YCC3048A1096A 46,500 13.00/11.00 80 653 31.5 50 80 38 x 59 x 44
4YCC3048A1120A 46,500 13.00/11.00 80 659 31.5 50 80 38 x 59 x 44
4YCC3060A1096A 58,000 13.00/10.95 80 670 43.3 60 79 40 x 59 x 44
4YCC3060A1120A 58,000 13.00/10.95 80 676 43.3 60 79 40 x 59 x 44
4YCC – 208/230/3/60
4YCC3036A3064A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 41
4YCC3036A3075A 35,000 13.00/11.00 80 488 18.5 30 75 36 x 49 x 41
4YCC3036A3096A 35,000 13.00/11.00 80 493 18.5 30 75 36 x 49 x 41
4YCC3048A3075A 46,500 13.00/11.00 80 645 24.0 35 80 38 x 59 x 44
4YCC3048A3096A 46,500 13.00/11.00 80 653 24.0 35 80 38 x 59 x 44
4YCC3048A3120A 46,500 13.00/11.00 80 659 24.0 35 80 38 x 59 x 44
4YCC3060A3096A 58,000 13.00/10.95 80 670 31.5 50 79 40 x 59 x 44
4YCC3060A3120A 58,000 13.00/10.95 80 676 31.5 50 79 40 x 59 x 44
4YCC – 460/3/60
4YCC3036A4064A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 41
4YCC3036A4075A 35,000 13.00/11.00 80 488 8.7 15 75 36 x 49 x 41
4YCC3036A4096A 35,000 13.00/11.00 80 493 8.7 15 75 36 x 49 x 41
4YCC3048A4075A 46,500 13.00/11.00 80 645 11.7 15 80 38 x 59 x 44
4YCC3048A4096A 46,500 13.00/11.00 80 653 11.7 15 80 38 x 59 x 44
4YCC3048A4120A 46,500 13.00/11.00 80 659 11.7 15 80 38 x 59 x 44
4YCC3060A4096A 58,000 13.00/10.95 80 678 19.3 25 79 40 x 59 x 44
4YCC3060A4120A 58,000 13.00/10.95 80 684 19.3 25 79 40 x 59 x 44
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCC3018A through 2/4YCC3036A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PG-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCC3018A through 2/4YCC3036A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PG-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCC3042A through 2/4YCC3060A

For information on Roof Curbs and


Roof Curb Adaptors, please refer to
the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PG-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2/4YCC3042A through 2/4YCC3060A

For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

2YCX 4YCX 2YCC 4YCC


Table PG-13-A — Accessories 2-5 1½-5 2-5 1½-5
BAYADAP050A ...... Adapter Curb (Cabinet A/B) .................................................................................. 1½-3 1½-3 1½-3 1½-3
BAYADAP051A ...... Adapter Curb (Cabinet C) ..................................................................................... 1½-3 1½-3 1½-3 1½-3
BAYADAP052A ...... Adapter Curb (Cabinet A/B) .................................................................................. 3½-5 3½-5 3½-5 3½-5
BAYADAP053A ...... Adapter Curb (Cabinet C) ..................................................................................... 3½-5 3½-5 3½-5 3½-5
BAYADAP054A ...... Adapter Curb (Cabinet D) ..................................................................................... 3½-5 3½-5 3½-5 3½-5
BAYCCHT101A ..... Crankcase Heater (230v) ..................................................................................... 2-2½, 3½-4 1½ 2-2½, 3½-4 1½
BAYCCHT102A ..... Crankcase Heater (230v) ..................................................................................... 3 3,4,5 3 3,4,5
BAYCCHT104A ..... Crankcase Heater (460v) ..................................................................................... — 3,4,5 — 3,4,5
BAYCOVR112A ..... 12" Duct Shroud (Covers Horizontal Ducts)0 ....................................................... 1½-5 1½-5 1½-5 1½-5
BAYCOVR118A ..... 18" Duct Shroud (Covers Horizontal Ducts)0 ....................................................... 1½-5 1½-5 1½-5 1½-5
BAYCURB050A ..... Flat Roof Curb (Insulated)5 .................................................................................. 1½- 3 1½- 3 1½- 3 1½- 3
BAYCURB051A ..... Flat Roof Curb (Insulated)6 .................................................................................. 3½-5 3½-5 3½-5 3½-5
BAYDMPR101A ..... Motorized Fresh Air Damper14 ........................................................................... 1½- 3 1½- 3 1½- 3 1½- 3
BAYDMPR102A ..... Motorized Fresh Air Damper14 ........................................................................... 3½-5 3½-5 3½-5 3½-5
BAYECON101A ..... Economizer with Barometric Relief1347 ............................................................ 1½- 3 1½- 3 1½- 3 1½- 3
BAYECON102A ..... Economizer with Barometric Relief1347 ............................................................ 3½-5 3½-5 3½-5 3½-5
BAYECON200A ..... Economizer (Horizontal)137 ............................................................................... 1½- 3 1½- 3 1½- 3 1½- 3
BAYECON201A ..... Economizer (Horizontal)137 ............................................................................... 3 ½-5 3 ½-5 3 ½-5 3 ½-5
BAYENTH100A ..... Enthalpy Control Kit3 ........................................................................................... ✔ ✔ ✔ ✔
BAYEXMK001A ..... Extreme Conditions Mounting Kit (Used on BAYCURB & BAYADAP) ................... ✔ ✔ ✔ ✔
BAYEXMK002A ..... Extreme Conditions Mounting Kit (Used on BAYUTIL) .......................................... ✔ ✔ ✔ ✔
BAYEXMK003A ..... Extreme Conditions Mounting Kit (Used on Slab Mounts) ..................................... ✔ ✔ ✔ ✔
BAYFLTR101A ....... 1-2" Filter Frame (20x20 filter not included)1 ........................................................ 1½- 3 1½- 3 1½- 3 1½- 3
BAYFLTR201A ....... 1-2" Filter Frame (20x20, 20x18 filters not included)1 .......................................... 3½-5 3½-5 3½-5 3½-5
BAYLIFT002BA ..... Lifting Lug Kit ....................................................................................................... ✔ ✔ ✔ ✔
BAYLOAM011A ..... Evaporator Defrost Control Kit .............................................................................. ✔ ✔ ✔ ✔
BAYLOAM105A ..... Head Pressure Control ......................................................................................... ✔ ✔ ✔ ✔
BAYLPKT100A ...... LP Conversion Kit ................................................................................................ 40K,120K 40K,120K 40K,120K 40K,120K
BAYLPKT101A ...... LP Conversion Kit ................................................................................................ 64K, 96K 64K, 96K 64K, 96K 64K, 96K
BAYLPKT102A ...... LP Conversion Kit ................................................................................................ 75K 75K 75K 75K
BAYOSAH001A ..... Manual Fresh Air Damper1 .................................................................................. 1½- 3 1½- 3 1½- 3 1½- 3
BAYOSAH002A ..... Manual Fresh Air Damper1 .................................................................................. 3½-5 3½-5 3½-5 3½-5
BAYQSTK301A ..... Quick Start Kit ...................................................................................................... ✔ ✔ ✔ ✔
BAYSQRD001A ..... 16" Round Duct Adapter9 .................................................................................... 1½- 3 1½- 3 1½- 3 1½- 3
BAYSQRD002A ..... 18" Round Duct Adapter9 .................................................................................... 1½-5 1½-5 1½-5 1½-5
BAYUTIL101A ....... Roof Curb Utility Extension Kit .............................................................................. 1½- 3 1½- 3 1½- 3 1½- 3
BAYUTIL102A ....... Roof Curb Utility Extension Kit .............................................................................. 3½-5 3½-5 3½-5 3½-5
1 Must use filter frame when economizer/fresh air kit is used.
2 Ships knocked down.
3 Dry bulb control standard with economizer.
4 Downflow Only.
5 Full perimeter curb for 2/4YC*3018-036A.
6 Full perimeter curb for 2/4YC*3042-060A.
7 2-Stage thermostat provides additional energy savings if simultaneous economizer and compressor operation is expected.
8 Do not use with programmable thermostats.
9 It is the responsibility of the installing dealer to properly size the ductwork for each specific application.
0 BAYCOVR112,118A will not cover BAYSQRD002A applications

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


selections and installation instructions, please PG-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

YCZ – XL 1600 YCX – XL 1200


YCY – XL 1400

Table PG-14-A — YCZ – XL 1600 Convertible Package Gas/Electric


Cooling Heating Output Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. Sound
Model No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
YCZ – 208-230/1/60 Stage 1 - Stage 2
YCZ036F1M0B 16.05/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 27.1 40 80 R1/ 2
YCZ050F1H0A 16.00/11.60 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 693 32 40 82 R1
YCZ060F1M0B 15.20/11.00 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 723 43.5 70 84 R1 /2
YCZ – 208-230/3/60 Stage 1 - Stage 2
YCZ036F3M0B 16.05/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 588 19.6 30 80 R1/ 2
YCZ050F3H0A 16.00/11.60 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 693 26 30 82 R1
YCZ060F3M0B 15.20/11.00 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 723 30.9 45 84 R1/ 2
YCZ – 460/3/60 Stage 1 - Stage 2
YCZ036F4M0A 15.60 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 613 11.4 15 80 R1/ 2
YCZ050F4H0A 14.00 51,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 718 15.1 20 82 R1
YCZ060F4M0A 14.85 59,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 748 20.3 30 82 R1/ 2

Table PG-14-B — YCY – XL 1400 Convertible Package Gas/Electric


Cooling Heating Output Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. Sound
Model No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
YCY – 208-230/1/60 Stage 1 - Stage 2
YCY024G1L0A 14.00/12.00 24,000 30,000 – 37,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 444 15.9 25 80 R1
YCY024G1M0A 14.00/12.00 24,000 44,000 – 53,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 455 15.9 25 80 R1
YCY030G1L0A 13.00/11.00 30,600 31,000 – 38,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 474 21.4 30 80 R2
YCY030G1M0A 13.00/11.00 30,600 44,000 – 55,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 485 21.4 30 80 R2
YCY036G1M0A 14.00/12.00 36,000 45,000 – 57,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 508 24.8 40 80 R2
YCY036G1H0A 14.00/12.00 36,000 61,000 – 72,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 513 24.8 40 80 R2
YCY042G1M0A 14.00/11.70 41,500 65,000 – 78,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 513 26.7 40 80 R2
YCY048G1H0A 14.40/12.20 49,000 73,000 – 95,500 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 639 32.7 45 84 R2
YCY060G1M0A 13.00/11.00 61,000 72,000 – 96,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 659 46.8 70 84 S

Table PG-14-C — YCX – XL 1200 Convertible Package Gas/Electric


Cooling Heating Output Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. Sound
Model No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
YCX – 208-230/1/60
YCX024G1L0B 12.00/10.50 24,500 30,000-38,000 80 25 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 380 15.6 25 80 R1
YCX024G1M0B 12.00/10.50 24,500 46,000-57,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 397 15.6 25 80 R1
YCX030G1L0A 12.05/10.90 30,600 30,000-38,000 80 29 x 36 x 56 (B) 10 x 171/2 189/16x 111/16 396 20.3 30 80 S
YCX030G1M0A 12.05/10.90 30,600 44,000-56,000 80 29 x 36 x 56 (B) 10 x 171/2 189/16 x 111/16 403 20.3 30 80 S
YCX036G1L0A 12.05/10.50
YCX036G1M0A 12.05/10.50
YCX036G1H0A 12.05/10.50
YCX042G1M0A 12.05/10.55
YCX048G1H0A 12.50/11.45
PHASED OUT
37,000
37,000
37,000
43,000
48,000
32,000-39,000
48,000-57,000
60,000-76,000
60,000-76,000
78,000-95,000
80
80
80
80
80
29 x 36 x 56 (B/C)
29 x 36 x 56 (B/C)
29 x 36 x 64 (B/C)
29 x 36 x 64 (C)
33 x 45 x 65 (D)
10 x 171/2
10 x 171/2
10 x 171/2
10 x 171/2
14 x 20
189/16 x 111/16
189/16 x 111/16
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
412
419
440
454
582
24.0
24.0
24.0
27.9
31.1
40
40
40
45
45
80
80
80
80
84
S
S
S
S
S
YCX060G1M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 43.7 70 84 S
1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
For information on Roof Curbs and Roof Curb Adaptors, please refer to the Accessories/Information Tab.
For complete equipment / combination
Effective 1/1/06 PG-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 2 through 5 Tons

YCX – XL 1200 YCP – XE 1200

Table PG-15-A — YCX – XL 1200 Convertible Package Gas/Electric


Cooling 1
Heating Output1 Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. Sound
Model No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
YCX – 208-230/3/60
YCX036G3L0A 12.05/10.5 37,000 32,000-39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 17.4 25 80 S
YCX036G3M0A 12.05/10.50 37,000 48,000-57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 17.4 25 80 S
YCX036G3H0A 12.05/10.50 37,000 60,000-76,000 80 29 x 36 x 64 (B/C) 10 x 171/2 189/16 x 111/16 440 17.4 25 80 S
YCX042G3M0A 12.05/10.55 43,000 60,000-76,000 80 29 x 36 x 64 (C) 10 x 171/2 189/16 x 111/16 454 19.9 30 80 S
YCX048G3H0A 12.50/11.45
YCX060G3M0A 12.05/10.55
YCX – 460/3/60
YCX036G4H0A 12.05/10.50
PHASED OUT
48,000
61,500
78,000-95,000
80,000-97,000

37,000 60,000-76,000
80
80

80
33 x 45 x 65 (D)
33 x 45 x 65 (D)
14 x 20
14 x 20

29 x 36 x 64 (B/C) 10 x 171/2
211/16 x 151/16
211/16 x 151/16

189/16 x 111/16
582
609

440
24.5
30.6

10.0
35
45

15
84
84

80
S
S

S
YCX048G4H0A 12.50/11.45 48,000 78,000-95,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 582 15.4 20 84 S
YCX060G4M0A 12.05/10.55 61,500 80,000-97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 15.1 20 84 S

Table PG-15-B — YCP – XE 1200 Convertible Package Gas/Electric


Cooling 1
Heating Output1 Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. Sound
Model No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
YCP – 208-230/1/60
YCP024F1L0B 12.00/10.50 24,200 30,000 – 38,000 80 25 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 380 14.6 20 80 R1
YCP024F1M0B 12.00/10.50 24,000 46,000 – 57,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 397 14.8 20 80 R1
YCP030F1L0A 12.00/10.90 30,000 30,000 – 38,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 396 21.2 30 80 S

T
YCP030F1M0A 12.00/10.90 30,000 44,000 – 56,000 80 29 x 36 x 56 (A/B) 10 x 171/2 189/16 x 111/16 403 21.2 30 80 S
YCP036F1L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 24.4 40 80 S
YCP036F1M0A 12.0010.50
YCP036F1H0A 12.00/10.50
YCP042F1M0A 12.00/10.55
YCP048F1H0A 12.20/11.45
OU
36,000
36,000
42,000
47,000
48,000 – 57,000
60,000 – 76,000
60,000 – 76,000
78,000 – 95,000
80
80
80
80
29 x 36 x 56 (B/C)
29 x 36 x 64 (B/C)
29 x 36 x 64 (B/C)
33 x 45 x 65 (D)
10 x 171/2
10 x 171/2
10 x 171/2
14 x 20
189/16 x 111/16
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
419
440
454
582
24.4
24.4
26.8
31.9
40
40
40
50
80
80
80
84
S
S
S
S
YCP060F1M0A 12.00/10.55
YCP – 208-230/3/60

ED 60,000 80,000 – 97,000 80 33 x 45 x 65 (D) 14 x 20 211/16 x 151/16 609 45.0 70 84 S

S
YCP036F3L0A 12.00/10.50 36,000 32,000 – 39,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 412 17.4 25 80 S
YCP036F3M0A 12.00/10.50 36,000 48,000 – 57,000 80 29 x 36 x 56 (B/C) 10 x 171/2 189/16 x 111/16 419 17.4 25 80 S
YCP036F3H0A 12.00/10.50
YCP042F3M0A 12.00/10.55
YCP048F3H0A 12.20/11.45

HA 36,000
42,000
47,000
60,000 – 76,000
60,000 – 76,000
78,000 – 95,000
80
80
80
29 x 36 x 64 (B/C)
29 x 36 x 64 (B/C)
33 x 45 x 65 (D)
10 x 171/2
10 x 171/2
14 x 20
189/16 x 111/16
189/16 x 111/16
211/16 x 151/16
440
454
582
17.4
19.9
24.5
25
30
35
80
80
84
S
S
S
YCP060F3M0A 12.00/10.55
YCP – 460/3/60
YCP036F4H0A 12.00/10.50
YCP048F4H0A 12.20/11.45
YCP060F4M0A 12.00/10.55
P 60,000 80,000 – 97,000

36,000 60,000 – 76,000 80


47,000 78,000 – 95,000 80
60,000 80,000 – 97,000 80
80 33 x 45 x 65 (D) 14 x 20

29 x 36 x 64 (B/C) 10 x 171/2
33 x 45 x 65 (D) 14 x 20
33 x 45 x 65 (D) 14 x 20
211/16 x 151/16

189/16 x 111/16
211/16 x 151/16
211/16 x 151/16
609

440
582
609
30.6

10.0
15.4
15.1
45

15
20
20
84

80
84
84
S

S
S
S
1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll
For information on Roof Curbs and Roof Curb Adaptors,
please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PG-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

YCC – XE 1000

Table PG-16-A —YCC – XE 1000 Convertible Package Gas/Electric


Cooling 1
Heating Output1 Cabinet Supply/Return Supply/Return Shipping
Unit Capacity Capacity Dimensions (in.) Downflow Horizontal Weight Max. Sound
Model No. SEER/EER* (Btuh) (Btuh) AFUE% H x W x L WxL H xW (Ibs.) MCA* Fuse* Rating Comp.
YCC – 208-230/1/60
YCC018F1L0B 10.00/9.35 18,000 32,000-40,000 78 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 341 13.2 20 80 R1
YCC024F1L0B 10.00/9.10 23,400 32,000-40,000 78 25 x 36 x 55 (A) 10 x 171/2 189/16 x 111/16 350 15.7 25 80 R1
YCC030F1L0B 10.00/9.20 29,200 32,000-40,000 78 25 x 36 x 55 (A/B) 10 x 171/2 189/16 x 111/16 398 20.1 30 80 R1
YCC030F1M0B 10.00/9.20 29,800 48,000-60,000 78 29 x 36 x 55 (A/B) 10 x 171/2 189/16 x 111/16 398 21.3 35 80 R1

PHASED OUT
YCC036F1L0B 10.00/8.75 35,200 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 420 25.2 40 80 R1/2
YCC036F1M0B 10.00/8.75 35,200 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 426 25.2 40 80 R1/2
YCC036F1H0B 10.00/8.75 35,200 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 25.2 40 80 R1/2
YCC042F1M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 171/2 189/16 x 111/16 454 30.2 50 80 R2
YCC048F1M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 171/2 189/16 x 111/16 461 33 50 80 R2
YCC048F1H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 34.4 50 84 R2
YCC060F1M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 43.9 70 84 R2

YCC – 208-230/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.


YCC036F3L0B 10.00/8.75 35,400 32,000-40,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 420 18 25 80 R1/2
YCC036F3M0B 10.00/8.75 35,400 48,000-60,000 78 29 x 36 x 55 (B/C) 10 x 171/2 189/16 x 111/16 426 18 25 80 R1/2
YCC036F3H0B 10.008.75 35,400 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 18 25 80 R1/2
YCC042F3M0B 10.00/9.50 42,000 64,000-80,000 78 29 x 36 x 63 (C) 10 x 171/2 189/16 x 111/16 454 22 35 80 R2
YCC048F3M0B 10.00/9.25 46,500 64,000-80,000 78 29 x 36 x 63 (C/D) 10 x 171/2 189/16 x 111/16 461 24.8 40 84 R2
YCC048F3H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 26.8 40 84 R2
YCC060F3M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 31 45 84 R2
YCC – 460/3/60 - LIMITED AVAILABILITY 3 PHASE ONLY, 2006.
YCC036F4H0B 10.00/8.75 35,400 64,000-80,000 78 29 x 36 x 63 (B/C) 10 x 171/2 189/16 x 111/16 454 8 15 80 R1/2
YCC048F4H0B 10.00/9.25 48,000 80,000-100,000 78 33 x 45 x 64 (C/D) 14 x 20 211/16 x 151/16 576 12.2 15 84 R2
YCC060F4M0B 10.00/9.20 60,000 80,000-100,000 78 33 x 45 x 64 (D) 14 x 20 211/16 x 151/16 604 15.6 25 84 R2
1 Low/High output - Unit ships standard high heat configuration. Low-fire operation requires optional BAYLOFR001-007 kit.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
Compressor Types are: R1 = Reciprocating One Cylinder, R2 = Reciprocating Two Cylinder, S = Scroll

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PG-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

YCZ YCY-G YCX-G YCP-F YCC-F


Table PG-17-A — Features 3-5 Ton 2-5 Ton 2-5 Ton 2-5 Ton 11/2-5 Ton
• Climatuff® Compressor (2) ........................................................................................................ ✔ — — — —
• Climatuff® Compressor (1) ........................................................................................................ — ✔ ✔ ✔ ✔
• Coil Sav’RTM guard ...................................................................................................................... ✔ ✔ ✔ — —

T
• Comfort "R"™ mode option ....................................................................................................... ✔ ✔ — — —
• Aluminized steel tubular heat exchanger ..................................................................................... ✔ ✔ ✔ ✔ ✔

OU
• Direct spark ignition ..................................................................................................................... ✔ ✔ ✔ ✔ ✔
• Dual firing rates (w/optional accessory) ...................................................................................... — — ✔ ✔ ✔
• GE ECM variable speed fan ........................................................................................................ ✔ ✔ — — —
• Heavy Vinyl - coated coil guard ................................................................................................... — — — ✔ —

ED
• Horizontal convertible to downflow .............................................................................................. ✔ ✔ ✔ ✔ ✔
• Lite Port/Stored diagnostics ......................................................................................................... ✔ ✔ ✔ ✔ ✔
• L.P. convertible ............................................................................................................................. ✔ ✔ ✔ ✔ ✔
✔ ✔ ✔ ✔ ✔

AS
• Meets California NOX (as shipped) .............................................................................................
• Multi-port in-shot burner .............................................................................................................. ✔ ✔ ✔ ✔ ✔
• Plate Fin coils .............................................................................................................................. ✔ ✔ ✔ ✔ ✔
• Two-stage cooling ........................................................................................................................ ✔ — — — —

PH
• Two-stage gas valve .................................................................................................................... ✔ ✔ — — —
• 5-year limited compressor only warranty (Commercial use) ........................................................ ✔ ✔ ✔ ✔ ✔
• 5-year limited compressor and outdoor coil warranty (Residential use) ...................................... — — — ✔ ✔
• 5-year limited heat exchanger warranty (Commercial use) ......................................................... ✔ ✔ ✔ ✔ ✔
• 5-year limited parts warranty (Residential use) ........................................................................... ✔ ✔ ✔ ✔ ✔
• 1-year limited parts warranty (Commercial use) .......................................................................... ✔ ✔ ✔ ✔ ✔
• 10-year limited compressor and outdoor coil warranty (Residential use) .................................... ✔ ✔ ✔ — —
• 10-year limited heat exchanger warranty (Residential use) ......................................................... — — — ✔ ✔
• 20-year limited heat exchanger warranty (Residential use) ......................................................... ✔ ✔ ✔ — —
Table PG-17-B — Comfort Controls
AY28X092 ............. Heat/Cool (Horizontal) ...................................................................................... ✔ ✔ ✔
BAY28X1821 ....... 1-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔
BAY28X1831 ...... 2-Stage Htg/Clg ................................................................................................ ✔ ✔ ✔
BAY28X184 ........... Subbase Auto/Manual Changeover .................................................................. ✔ ✔ ✔
BAY28X187 ........... Subbase Auto Changeover ............................................................................... ✔ ✔ ✔
BAY28X190 ........... Locking Thermostat Cover for Room Thermostat .............................................. ✔ ✔ ✔
BAYBASE006A ...... Used w/BAYSTAT040B, 2 Htg / 2 Clg w/Economizer ........................................ ✔ ✔ ✔

T
BAYBASE008A ...... Used w/BAYSTAT040B, 1 Htg / 1 Clg ............................................................... ✔ ✔ ✔

OU
BAYCOVR100A ..... Wall Cover Plate ............................................................................................... ✔ ✔ ✔
BAYSTAT008 ......... Manual 1-Stage Htg/Clg ................................................................................... ✔ ✔ ✔
BAYSTAT010 ......... Auto 2-Stage Heating/Cooling .......................................................................... ✔ ✔ ✔
Zone Sensors Section

Zone Sensors Section


See Comfort Controls/

See Comfort Controls/

BAYSTAT012 ......... Manual 1-Stage Htg/2-Stage Clg w/Economizer ............................................... ✔ ✔ ✔


BAYSTAT040B ....... Programmable (used with BAYBASE) ............................................................... ✔ ED ✔ ✔
BAYSTAT253A ....... Humidity Control ............................................................................................... — — —
BAYSTAT305 ......... Heat/Cool (Vertical) .......................................................................................... ✔ ✔ ✔
TAYSENS100A2 ... Outdoor Temp. Sensor (with case) .................................................................... ✔ ✔ ✔
AS

TAYSTAT241 .......... Manual 2-Stage Htg/1-Stage Clg ...................................................................... ✔ ✔ ✔


TAYSTAT300C ....... 7 day Programmable 1 Htg/1 Clg ...................................................................... ✔ ✔ ✔
TAYSTAT302C ....... 7 day Programmable 2 Htg/2 Clg w/Economizer ............................................... ✔ ✔ ✔
PH

TAYSTAT340 .......... Prog., 5/2 Day, Manual, 1Htg/1 Clg ................................................................... ✔ ✔ ✔


TAYSTAT350 .......... Prog., 5/2 Day, Manual, 2 (Gas)Htg/1 Clg ......................................................... ✔ ✔ ✔
TAYSTAT370 .......... Electronic, Auto 1 Htg (Gas)/ 1Clg (Non Prog) .................................................. ✔ ✔ ✔
TAYSTAT375 .......... Electronic, 2 Htg/ 2Clg (Non Prog) .................................................................... ✔ ✔ ✔
TAYSTAT380 .......... Electronic, 2 Htg (Gas)/ 1Clg (Non Prog) .......................................................... — — —
TCONT200A .......... 1Htg /1Clg (Gas, Oil or Electric) ........................................................................ ✔ ✔ ✔
TCONT401A .......... 2Htg /1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT402A .......... 3Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT600A .......... 1Htg /1Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT602A .......... 2Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT800A .......... 1Htg /1Clg (Gas, Oil or Electric) ........................................................................ ✔ ✔ ✔
TCONT802A .......... 3Htg /2Clg (Heat Pump/A/C) ............................................................................ ✔ ✔ ✔
TCONT803A .......... 3Htg /2Clg (Heat Pump/A/C) w/Humidity Control .............................................. ✔ ✔ ✔
1 Requires Subbase.
2 Used with TAYSTAT300C and TAYSTAT302C only.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PG-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons
YCZ-F YCY-G YCX-G YCP-F YCC-F
Table PG-18-A — Accessories 3-5 2-5 2-5 2-5 11/2-5
BAYASCT00178 .... Anti-Short Cycle Timer ..................................................................................... 3-5 2-5 2-5 2-5 1½-5
BAYCCHT003A ...... Crankcase Heater (230v)1 ............................................................................. — 2-3½ 2 2 1½-5
BAYCCHT202A ...... Crankcase Heater (230v) ................................................................................. — 2½-5 2½-5 2½-5 —
BAYCCHT400A ...... Crankcase Heater (460v) ................................................................................. — — 2½-5 2½-5 —
BAYCURB030A ...... Roof Curb (Flat Roof)3 (14 H x 34 W x 531/8 L) ............................................... 3-5 3-5 2-5 2-5 1½-5
BAYCURB033A ...... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 34 W x 605/8 L) .......................... 3 2-3½ 3½ M/H 36H-42M 3H,3½-4M
BAYCURB034A ...... Roof Curb (Flat Roof)3 Acousti-Curb (14 H x 43 W x 621/16 L) .......................... 4-5 4-5 4-5 4-5 4H, 5M
BAYCURB038A ...... Roof Curb (Flat Roof)3Acousti-Curb (14 H x 34 W x 531/8 L) .......................... 3-5 2-5 2-5 2-5 1½-5
BAYDMPR040A ..... 0-25% Manual Fresh Air Damper (Downflow Only)2 ...................................... 3 2-3½ 2-3½ 2-3½ 1½-4M

PHASED OUT
BAYDMPR041A ..... 0-25% Manual Fresh Air Damper (Downflow Only)2 ...................................... 4-5 4-5 4-5 4-5 4H-5M
BAYDMPR050A ..... Motorized Fresh Air Damper ............................................................................ — — 4H-5M 4H-5M 4H-5M
BAYDUCT004A ...... 12" Round Duct Adapters (2 per Box) Horizontal Only ..................................... 3 2-3½ 2-3½ 2-3½ 1½-4M
BAYDUCT005A ...... 14" Round Duct Adapters (1 per Box) Horizontal Only ..................................... 4 2-3½ 2-3½ 2-3½ 1½-4M
BAYECMT002A ...... Extreme Conditions Mouniting Kit (Curb Mount) .............................................. 3-5 2-5 2-5 2-5 1½-5
BAYECMT003A ...... Extreme Conditions Mouniting Kit (Slab or Rack Mount) ................................. 3-5 2-5 2-5 2-5 1½-5
BAYECON054B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ............................ 3 2-3½ 2-3½ 2-3½ 1½-4M
BAYECON055B ...... 0-100% Mod. Economizer with Bar Relief – Downflow246 ........................... 4-5 4-5 4-5 4-5 4H, 5M
BAYECON073A ...... 0-100% Mod. Economizer – Horizontal246 .................................................. 3-5 2-5 2-5 2-5 1½-5
BAYENTH001A ...... Enthalpy Control (Solid State)4 ...................................................................... 3-5 2-5 2-5 2-5 1½-5
BAYFLTR012A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LM
BAYFLTR013A ....... Filter Frame2 (20 x 25 x 1" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4M
BAYFLTR014A ....... Filter Frame2 (3-10 x 25 x 1" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5M
BAYFLTR015A ....... Filter Frame2 (20 x 20 x 1" filter not included) ................................................ — — 2L 2L 1½-2½L
BAYFLTR017A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ — — 2-3½M 2-3½M 2½M-3LM
BAYFLTR018A ....... Filter Frame2 (20 x 25 x 2" filter not included) ................................................ 3 2-3½LMH 3H-3½M 3H-3½M 3H-3½-4M
BAYFLTR019A ....... Filter Frame2 (2-16 x 25 x 2" filter not included) ............................................. 4H-5M 4H-5M 4H-5M 4H-5M 4H-5M
BAYGARD016A ...... Condenser Coil Guard ..................................................................................... — — — — 1½-2½L
BAYGARD017A ...... Condenser Coil Guard ..................................................................................... — — — — 3½-4M
BAYGARD018A ...... Condenser Coil Guard ..................................................................................... — — — — 2½M-3H
BAYGARD021A ...... Condenser Coil Guard ..................................................................................... — — — — 4H-5M
BAYHSMT043A ...... High Static Motor (230/460V) 3/4HP ................................................................ — — 2½-3½ 2½-3½ 2½-3½
BAYHSMT044A ...... High Static Motor (230/460V) 1HP ................................................................... — — 4-5 4-5 4-5
BAYHSMT045A ...... High Static Motor (208V) 1HP .......................................................................... — — 4-5 4-5 4-5
BAYHSMT056A ...... High Static Motor (208V) 3/4HP ....................................................................... — — 2½-3½ 2½-3½ 2½-3½
BAYINDK001A* ...... Insulated Deck Pan for A & B Cabinet .............................................................. — — 2-3LM 2-3LM 1½-3LM
BAYINDK002A** ..... Insulated Deck Pan for C Cabinet .................................................................... 3M 2-3½LMH 3H-3½M 3H-3½M 3H,3½-4M
BAYINDK003A*** ... Insulated Deck Pan for D Cabinet .................................................................... 4H-5M 4H-5M 4H-5M 4H-5M 4H-5M
BAYKSKT010A ....... Quick Start Kit for (Single Phase Units) ........................................................... — — — — 1½-5
BAYKSKT254 ......... Start Kit-Scroll Models Only (Single Phase Only) ............................................ — — 2½-4 2½-4 —
BAYLIFT002B ......... Lifting Lug Kit .................................................................................................. 3-5 2-5 2-5 2-5 1½-5
BAYLOAM011A ...... Evaporator Defrost Control Kit1 ....................................................................... 3-5 2-5 2-5 2-5 1½-5
BAYLOAM323A ...... Head Pressure Control15 ............................................................................... — 2-5 2-5 2-5 1½-5
BAYLOFR001B ...... Low Fire Kit ...................................................................................................... — — 1½-3L 1½-3L 1½-3L
BAYLOFR002B ...... Low Fire Kit ...................................................................................................... — — 2M 2M 2M
BAYLOFR003B ...... Low Fire Kit ...................................................................................................... — — 2½-3M 2½-3M 2½-3M
BAYLOFR004B ...... Low Fire Kit ...................................................................................................... — — 3H,3½M 3H,3½M 3H,3½M-4M
BAYLOFR005B ...... Low Fire Kit ...................................................................................................... — — — — —
BAYLOFR006B ...... Low Fire Kit ...................................................................................................... — — 4-5 4-5 —
BAYLOFR007B ...... Low Fire Kit ...................................................................................................... — — — — 4-5M, 4H
BAYLPKT022A ....... LP Conversion Kit ............................................................................................ — — 2-5 2-5 1½-5
BAYLPKT024C ....... LP Conversion Kit ............................................................................................ 3-5 2-5 — — —
BAYLPSS001A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. — — 2-5 2-5 1½-5
and 5 LP #54 orifices (Single Stage)
BAYLPSS002A ....... LP Conversion Kit with 5 Stainless steel burners ............................................. 3-5 2-5 — — —
and 5 LP #54 orifices (Two Stage)
BAYMOTR307A ...... 208-230V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A .............................. — 2-5 2-5 2-5 1½-5
BAYMOTR406A ...... 460V 1/2HP Ball Bearing OD Motor used with BAYLOAM323A ............................ — — 2-5 2-5 1½-5
BAYOSAC001A ...... Outside Air Econo Controller ............................................................................ 3-5 — — — —
BAYSTAT023 .......... Remote Potentiometer for BAYECON054B, 055B ............................................ 3-5 2-5 2-5 2-5 1½-5
BAYUTIL030A ........ Roof Curb Utility Extension Kit for BAYCURB030, 038A .................................. — — — — 1½-5
BAYUTIL033A ........ Roof Curb Utility Extension Kit for BAYCURB033A .......................................... — — — — 3H,3½-4M
BAYUTIL034A ........ Roof Curb Utility Extension Kit for BAYCURB034A .......................................... — — — — 4H, 5M
1 Low ambient cooling requires crankcase heater. 7 Activated on Power Off.
2 Must use filter frame when economizer/fresh air kit is used. 8 Not for use with programmable thermostat. For information on Roof Curbs
3 Ships knocked down. * Currently Shipped with BAYCURB038A.
4 Dry bulb control standard with economizer. ** Currently Shipped with BAYCURB033A. and Roof Curb Adaptors, please
5 May require motor change, see instruction guide. *** Currently Shipped with BAYCURB034A. refer to the Accessories/
6 2-Stage thermostat provides additional energy savings if simultaneous economizer L – Low heat model
Information Tab.
and compressor operation is expected. M – Medium heat model
H – High heat model
For complete equipment / combination
Effective 1/1/06 PG-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 2 through 5 Tons

A
B

EVAPORATOR COIL &


SUPPLY & BLOWER PANEL
RETURN PANEL

ECONOMIZER/FILTER
ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H 67 MM (2 5/8")

59 MM (2 5/16")
D
J D 48 MM (1 7/8") DIA. ENTRY
35 MM L FOR 13 MM (1/2) NPT
X
(1 3/8") M X GAS CONNECTION
Y 29 MM
Y (1 1/8")
L CONDENSATE DRAIN
K M 19 MM (3/4") FEMALE NPT
HORIZONTAL DOWNFLOW
SUPPLY P
76 MM RETURN OPENING
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING

Table PG-19-A — YCZ – XL 1600 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
YCZ036F-M 64 36 293/16 189/16 111/16 69/16 111/8 17 181/2 251/2 171/2 10 3 83/4 33A
YCZ050F-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 24 261/2 20 14 31/2 85/16 34A
YCZ060F-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 223/4 251/2 20 14 31/2 85/16 34A

Table PG-19-B — YCY – XL 1400 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
YCY024G-L 64 36 293/16 189/16 111/16 69/16 111/8 17 205/16 291/2 171/2 10 3 83/4 30A, 38A, 33A
YCY024G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 211/2 291/2 171/2 10 3 83/4 30A, 38A, 33A
YCY030G-L 64 36 293/16 189/16 111/16 69/16 111/8 17 195/16 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCY030G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 195/16 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCY036G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 191/2 287/32 171/2 10 3 83/4 30A, 38A, 33A
YCY036G-H 64 36 293/16 189/16 111/16 69/16 111/8 17 1913/16 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCY042G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 1913/16 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCY048G-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 297/32 20 14 31/2 85/16 30A, 38A, 34A
YCY060G-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 297/32 20 14 31/2 85/16 30A, 38A, 34A

Table PG-19-C — YCX – XL 1200 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
YCX024G-L 561/2 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38A
YCX030G-L 561/2 36 293/16 189/16 111/16 69/16 613/16 17 203/4 2513/16 171/2 10 3 47/16 30A, 38A

PHASED OUT
YCX036G-L 561/2 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38A
YCX024G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 211/2 23 171/2 10 3 83/4 30A, 38A
YCX030G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 201/2 25 171/2 10 3 83/4 30A, 38A
YCX036G-M 56 36 293/16 189/16 111/16 69/16 111/8 17 191/2 2715/16 171/2 10 3 83/4 30A, 38A
YCX036G-H 64 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCX042G-M 64 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCX048G-H 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A
YCX060G-M 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.
For complete equipment / combination
selections and installation instructions, please PG-19 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Package Gas/Electric
Convertible 1½ through 5 Tons

A
B

EVAPORATOR COIL &


SUPPLY & BLOWER PANEL
RETURN PANEL

ECONOMIZER/FILTER
ACCESS PANEL
E
F
E
G
C
CENTER OF
GRAVITY
H 67 MM (2 5/8")

59 MM (2 5/16")
D
J D 48 MM (1 7/8") DIA. ENTRY
35 MM L FOR 13 MM (1/2) NPT
M X
(1 3/8") X GAS CONNECTION
Y 29 MM
Y (1 1/8")
L CONDENSATE DRAIN
K M 19 MM (3/4") FEMALE NPT
HORIZONTAL DOWNFLOW
SUPPLY P
76 MM RETURN OPENING
OPENING DOWNFLOW (3")
SUPPLY HORIZONTAL N
OPENING RETURN OPENING

Table PG-20-A — YCP – XE 1200 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
YCP024F-L 56½ 36 253/16 189/16 111/16 69/16 613/16 17 21 21¼ 171/2 10 3 47/16 30A, 38A
YCP024F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38A
YCP030F-L 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38A

PHASED OUT
YCP030F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 21 217/8 171/2 10 3 47/16 30A, 38A
YCP036F-L 56½ 36 293/16 189/16 111/16 69/16 613/16 17 20½ 251/8 171/2 10 3 47/16 30A, 38A
YCP036F-M 56½ 36 293/16 189/16 111/16 69/16 613/16 17 20½ 251/8 171/2 10 3 47/16 30A, 38A
YCP036F-H 64 36 293/16 189/16 111/16 69/16 111/8 17 20½ 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCP042F-M 64 36 293/16 189/16 111/16 69/16 111/8 17 20½ 281/2 171/2 10 3 83/4 30A, 38A, 33A
YCP048F-H 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 30¼ 20 14 31/2 815/16 30A, 38A, 34A
YCP060F-M 651/8 45 333/8 211/16 151/16 415/16 91/8 2115/16 253/8 287/8 20 14 31/2 815/16 30A, 38A, 34A

Table PG-20-B — YCC – XE 1000 Dimensional Data


Model A B C D E F G H J K L M N P BAYCURB0
YCC018F-L 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38A
YCC024F-L 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38A
YCC030F-L 551/4 36 253/16 189/16 111/16 69/16 613/16 17 215/16 25 171/2 10 3 47/16 30A, 38A

PHASED OUT
YCC036F-L 551/4 36 293/16 189/16 111/16 69/16 613/16 17 203/4 2513/16 171/2 10 3 47/16 30A, 38A
YCC030F-M 551/4 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38A
YCC036F-M 551/4 36 293/16 189/16 111/16 69/16 613/16 17 193/4 2413/16 171/2 10 3 47/16 30A, 38A
YCC036F-H 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCC042F-M 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCC048F-M 623/4 36 293/16 189/16 111/16 69/16 111/8 17 193/4 281/4 171/2 10 3 83/4 30A, 38A, 33A
YCC048F-H 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A
YCC060F-M 645/16 45 333/8 211/16 151/16 415/16 91/8 2115/16 25 291/2 20 14 31/2 815/16 30A, 38A, 34A

For information on Roof Curbs and Roof Curb Adaptors,


please refer to the Accessories/Information Tab.

For complete equipment / combination


Effective 1/1/06 PG-20 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ 3-10 ton
Packaged Gas Electrics

Standard Features:
• Trane built scroll compressors on all 3-10 ton units except 3 ton standard efficiency
model (Reciprocating Compressor)
• Colored and numbered wiring
• Provisions for through the Base Gas and Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• 2" throwaway filters provided on 6-10 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
• 5 - year Limited Compressor Warranty
Featuring • 5 - year Limited Heat Exchanger Warranty
A New Look for a New Century • 1 - year Limited Parts Warranty
Beveled Top
Smoother Design Added Flexibility
Small compact cabinet
• Electromechanical or microprocessor controls (See page PC-35 for ReliaTel™
Recessed access handles
Control Information)
• Standard or high efficiency cooling models available
• Low, medium or high heat, single or two stage
• Convertible airflow
• Fork lift openings on three sides of unit
• Direct or belt drive - standard or oversized motors (Direct for 3-5 ton only)
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options


• Through-the-Base — Electrical
• Convenience Outlet — Powered or unpowered
• Unit Disconnect Switch
• Smoke Detectors — Supply, return, or both
• Condenser Coil Coating
• Hinged Access Service Panels
• Discharge Air Sensor
• Fan Fail and Clogged Filter Switches
• Condenser Coil Guard — Hail Protection Quality
• Hot Gas Reheat Coil - Dehumidification
• TXV thermal expansion valve and split face evaporator coil
• TCI (Trane Communication Interface)
• LonTalk (Communication Interface)
• 2" Pleated Media filters
• Phase Monitor
• Frostat

The same Trane Quality and


Reliability … with added Flexibility!

For complete equipment / combination


selections and installation instructions, please PG-21 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-22-A — Base Unit — Standard Efficiency — Electromechanical


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons 4
Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YSC – 208-230/1/60 – Single Phase – Low Heat
3 YSC036E1ELA0000 13.0 35,620 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 40
4 YSC048E1ELA0000 13.0 49,210 49,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 50
5 YSC060E1ELA0000 13.0 59,900 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70
YSC –208-230/3/60 – Three Phase – Low Heat
3 YSC036A3ELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 25
4 YSC048A3ELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 35
5 YSC060A3ELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 50
3 YSC036E3ELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 30
4 YSC048E3ELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 35
5 YSC060E3ELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 45
6 YSC072A3ELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 50
7½ YSC090A3ELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 60
7½ YSC092A3ELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3ELA0000 10.1 105,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 60
10 YSC120A3ELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60
YSC –460/3/60 – Three Phase – Low Heat
3 YSC036A4ELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 15
4 YSC048A4ELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 20
5 YSC060A4ELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 25
3 YSC036E4ELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 15
4 YSC048E4ELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 15
5 YSC060E4ELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 25
6 YSC072A4ELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 25
7½ YSC090A4ELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 35
7½ YSC092A4ELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 25
8½ YSC102A4ELA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 30
10 YSC120A4ELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35
YSC –575/3/60 – Three Phase – Low Heat
3 YSC036AWELA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 15
4 YSC048AWELA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 15
5 YSC060AWELA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 15
3 YSC036EWELA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 15
4 YSC048EWELA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 15
5 YSC060EWELA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 15
6 YSC072AWELA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 20
7½ YSC090AWELA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 25
7½ YSC092AWELA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 20
8½ YSC102AWELA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 25
10 YSC120AWELA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25
7½ YSC092A3EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3EMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 44.4 60
10 YSC120A3EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 50.9 60
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7 - A=R-22, E=410A.

For complete equipment / combination


Effective 1/1/06 PG-22 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-23-A — Base Unit — Standard Efficiency — Electromechanical


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons 4
Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YSC – 208-230/1/60 – Single Phase – Medium Heat
3 YSC036E1EMA0000 13.0 35,620 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 40
4 YSC048E1EMA0000 13.0 49,210 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 50
5 YSC060E1EMA0000 13.0 59,900 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70
YSC –208-230/3/60 – Three Phase – Medium Heat
3 YSC036A3EMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 25
4 YSC048A3EMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 35
5 YSC060A3EMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 50
3 YSC036E3EMA0000 13.0 37,150 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 30
4 YSC048E3EMA0000 13.0 49,450 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 35
5 YSC060E3EMA0000 13.0 62,270 64,000 81 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 45
6 YSC072A3EMA0000 10.2/10.11 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.2 50
7½ YSC090A3EMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 60
7½ YSC092A3EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3EMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 44.4 60
10 YSC120A3EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 50.9 60
YSC –460/3/60 – Three Phase – Medium Heat
3 YSC036A4EMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 15
4 YSC048A4EMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 20
5 YSC060A4EMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 25
3 YSC036E4EMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 15
4 YSC048E4EMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 15
5 YSC060E4EMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 25
6 YSC072A4EMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 25
7½ YSC090A4EMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 35
7½ YSC092A4EMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 25
8½ YSC102A4EMA0000 10.11 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 30
10 YSC120A4EMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35
YSC –575/3/60 – Three Phase – Medium Heat
3 YSC036AWEMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 15
4 YSC048AWEMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 15
5 YSC060AWEMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 15
3 YSC036EWEMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 15
4 YSC048EWEMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 15
5 YSC060EWEMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 15
6 YSC072AWEMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 20
7½ YSC090AWEMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 25
7½ YSC092AWEMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 20
8½ YSC102AWEMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 25
10 YSC120AWEMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7 - A=R-22, E=410A.

For complete equipment / combination


selections and installation instructions, please PG-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-24-A — Base Unit — Standard Efficiency — Electromechanical


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons 4
Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YSC –208-230/1/60 – Single Phase – High Heat
3 YSC036E1EHA0000 13.0 35,620 94,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 40
4 YSC048E1EHA0000 13.0 49,210 95,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 50
5 YSC060E1EHA0000 13.0 59,900 103,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70
YSC –208-230/3/60 – Three Phase – High Heat
3 YSC036A3EHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 17.9 25
4 YSC048A3EHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 23.9 35
5 YSC060A3EHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 31.5 50
3 YSC036E3EHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 30
4 YSC048E3EHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 35
5 YSC060E3EHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 45
6 YSC072A3EHA0000 10.1 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 50
7½ YSC090A3EHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 60
7½ YSC092A3EHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3EHA0000 10.11 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 60
10 YSC120A3EHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60
YSC –460/3/60 – Three Phase – High Heat
3 YSC036A4EHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 9.2 15
4 YSC048A4EHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 12.8 20
5 YSC060A4EHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 16.0 25
3 YSC036E4EHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 15
4 YSC048E4EHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 15
5 YSC060E4EHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 25
6 YSC072A4EHA0000 10.1 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 25
7½ YSC090A4EHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 35
7½ YSC092A4EHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 25
8½ YSC102A4EHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 30
10 YSC120A4EHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35
YSC –575/3/60 – Three Phase – High Heat
3 YSC036AWEHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 7.7 15
4 YSC048AWEHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 9.8 15
5 YSC060AWEHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 12.2 15
3 YSC036EWEHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 15
4 YSC048EWEHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 15
5 YSC060EWEHA0000 13.0 2,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 15
6 YSC072AWEHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 20
7½ YSC090AWEHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 25
7½ YSC092AWEHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 20
8½ YSC102AWEHA0000 /10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 25
10 YSC120AWEHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7 - A=R-22, E=410A.

For complete equipment / combination


Effective 1/1/06 PG-24 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-25-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor Controls


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons 4
Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YSC – 208-230/1/60 – Single Phase – Low Heat
3 YSC036E1RLA0000 13.0 35,620 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 40
4 YSC048E1RLA0000 13.0 49,210 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 50
5 YSC060E1RLA0000 13.0 59,900 47,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70
YSC –208-230/3/60 – Three Phase – Low Heat
3 YSC036A3RLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 25
4 YSC048A3RLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 35
5 YSC060A3RLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 50
3 YSC036E3RLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 30
4 YSC048E3RLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 35
5 YSC060E3RLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 45
6 YSC072A3RLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 50
7½ YSC090A3RLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 60
7½ YSC092A3RLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3RLA0000 10.1 105,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 60
10 YSC120A3RLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60
YSC –460/3/60 – Three Phase – Low Heat
3 YSC036A4RLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 15
4 YSC048A4RLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 20
5 YSC060A4RLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 25
3 YSC036E4RLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 15
4 YSC048E4RLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 15
5 YSC060E4RLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 25
6 YSC072A4RLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 25
7½ YSC090A4RLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 35
7½ YSC092A4RLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 25
8½ YSC102A4RLA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 30
10 YSC120A4RLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35
YSC –575/3/60 – Three Phase – Low Heat
3 YSC036AWRLA0000 10.7 37,400 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 15
4 YSC048AWRLA0000 10.0 49,200 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 15
5 YSC060AWRLA0000 10.2 63,100 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 15
3 YSC036EWRLA0000 13.0 37,150 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 15
4 YSC048EWRLA0000 13.0 49,450 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 15
5 YSC060EWRLA0000 13.0 62,270 48,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 15
6 YSC072AWRLA0000 10.2/10.11 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 20
7½ YSC090AWRLA0000 10.1 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 25
7½ YSC092AWRLA0000 10.4/10.11 90,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 20
8½ YSC102AWRLA0000 10.1 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 25
10 YSC120AWRLA0000 10.2/10.11 117,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7 - A=R-22, E=410A..

For complete equipment / combination


selections and installation instructions, please PG-25 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-26-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor Controls


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons 4
Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YSC – 208-230/1/60 – Single Phase – Medium Heat
3 YSC036E1RMA0000 13.0 35,620 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 40
4 YSC048E1RMA0000 13.0 49,210 65,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 50
5 YSC060E1RMA0000 13.0 59,900 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70
YSC –208-230/3/60 – Three Phase – Medium Heat
3 YSC036A3RMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 17.9 25
4 YSC048A3RMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 23.9 35
5 YSC060A3RMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 31.5 50
3 YSC036E3RMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 30
4 YSC048E3RMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 35
5 YSC060e3RMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 45
6 YSC072A3RMA0000 10.2/10.11 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 50
7½ YSC090A3RMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 60
7½ YSC092A3RMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3RMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 60
10 YSC120A3RMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60
YSC –460/3/60 – Three Phase – Medium Heat
3 YSC036A4RMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 9.2 15
4 YSC048A4RMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 12.8 20
5 YSC060A4RMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 16.0 25
3 YSC036E4RMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 15
4 YSC048E4RMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 15
5 YSC060E4RMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 25
6 YSC072A4RMA0000 10.2/10.11 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 25
7½ YSC090A4RMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 35
7½ YSC092A4RMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 25
8½ YSC102A4RMA0000 10.1 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 30
10 YSC120A4RMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35
YSC –575/3/60 – Three Phase – Medium Heat
3 YSC036AWRMA0000 10.7 37,400 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 572 7.7 15
4 YSC048AWRMA0000 10.0 49,200 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 597 9.8 15
5 YSC060AWRMA0000 10.2 63,100 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 614 12.2 15
3 YSC036EWRMA0000 13.0 37,150 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 15
4 YSC048EWRMA0000 13.0 49,450 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 15
5 YSC060EWRMA0000 13.0 62,270 64,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 15
6 YSC072AWRMA0000 10.1 63,100 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 20
7½ YSC090AWRMA0000 10.1 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 25
7½ YSC092AWRMA0000 10.4/10.11 90,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 20
8½ YSC102AWRMA0000 10.2 105,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 25
10 YSC120AWRMA0000 10.2/10.11 117,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 21.8 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7 - A=R-22, E=410A.

For complete equipment / combination


Effective 1/1/06 PG-26 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-27-A — Base Unit — Standard Efficiency — ReliaTel™ Microprocessor Controls


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons 4
Ordering No.4 SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YSC –208-230/1/60 – Single Phase – High Heat
3 YSC036E1RHA0000 13.0 35,620 94,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 27.2 40
4 YSC048E1RHA0000 13.0 49,210 95,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 35.2 50
5 YSC060E1RHA0000 13.0 59,900 103,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 43.8 70
YSC –208-230/3/60 – Three Phase – High Heat
3 YSC036A3RHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 17.9 25
4 YSC048A3RHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 23.9 35
5 YSC060A3RHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 31.5 50
3 YSC036E3RHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 21.4 30
4 YSC048E3RHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 25.2 35
5 YSC060E3RHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 29.5 45
6 YSC072A3RHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 32.7 50
7½ YSC090A3RHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 42.7 60
7½ YSC092A3RHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 38.9 50
8½ YSC102A3RHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 45.1 60
10 YSC120A3RHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 52.6 60
YSC –460/3/60 – Three Phase – High Heat
3 YSC036A4RHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 9.2 15
4 YSC048A4RHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 12.8 20
5 YSC060A4RHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 16.0 25
3 YSC036E4RHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 10.1 15
4 YSC048E4RHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 12.5 15
5 YSC060E4RHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 15.5 25
6 YSC072A4RHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 17.6 25
7½ YSC090A4RHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 22.6 35
7½ YSC092A4RHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 20.5 25
8½ YSC102A4RHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 24.0 30
10 YSC120A4RHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1130 26.9 35
YSC –575/3/60 – Three Phase – High Heat
3 YSC036AWRHA0000 10.7 37,400 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 572 7.7 15
4 YSC048AWRHA0000 10.0 49,200 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 597 9.8 15
5 YSC060AWRHA0000 10.2 63,100 104,000 81 36 x 44 x 70 18 x 15.5 24 x 14 614 12.2 15
3 YSC036EWRHA0000 13.0 37,150 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 607 8.0 15
4 YSC048EWRHA0000 13.0 49,450 96,000 80 32 x 44 x 70 18 x 15.5 12 x 14 638 9.0 15
5 YSC060EWRHA0000 13.0 62,270 104,000 80 32 x 44 x 70 18 x 15.5 12 x 14 688 10.1 15
6 YSC072AWRHA0000 10.2/10.11 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 878 12.8 20
7½ YSC090AWRHA0000 10.1 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 963 17.6 25
7½ YSC092AWRHA0000 10.4/10.11 90,000 162,000 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 965 15.5 20
8½ YSC102AWRHA0000 10.1 105,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1042 19.5 25
10 YSC120AWRHA0000 10.2/10.11 117,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 11300 21.8 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.
4 Digit 7 - A=R-22, E=410A.

For complete equipment / combination


selections and installation instructions, please PG-27 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-28-A — Base Unit — High Efficiency — Electromechanical


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YHC –208-230/3/60 – Three Phase – Low Heat
6 YHC072A3ELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 50
7½ YHC092A3ELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 50
8½ YHC102A3ELA0000 11.5/11.31 102,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 50
10 YHC120A3ELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60
YHC –460/3/60 – Three Phase – Low Heat
6 YHC072A4ELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 25
7½ YHC092A4ELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 25
8½ YHC102A4ELA0000 11.5/11.31 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 25
10 YHC120A4ELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30
YHC –575/3/60 – Three Phase – Low Heat
6 YHC072AWELA0000 11.5/11.31 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 20
7½ YHC092AWELA0000 11.5/11.31 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 15
8½ YHC102AWELA0000 11.5/11.31 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 20
10 YHC120AWELA0000 11.2/10.71 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25
YHC –208-230/3/60 – Three Phase – Medium Heat
6 YHC072A3EMA0000 11.5/11.31 72,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 50
7½ YHC092A3EMA0000 11.5/11.31 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 50
8½ YHC102A3EMA0000 11.5/11.31 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 50
10 YHC120A3EMA0000 11.2/10.71 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60
YHC –460/3/60 – Three Phase – Medium Heat
6 YHC072A4EMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 25
7½ YHC092A4EMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 25
8½ YHC102A4EMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 25
10 YHC120A4EMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30
YHC –575/3/60 – Three Phase – Medium Heat
6 YHC072AWEMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 20
7½ YHC092AWEMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 15
8½ YHC102AWEMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 20
10 YHC120AWEMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25
YHC –208-230/3/60 – Three Phase – High Heat
6 YHC072A3EHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 50
7½ YHC092A3EHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 50
8½ YHC102A3EHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 50
10 YHC120A3EHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60
YHC –460/3/60 – Three Phase – High Heat
6 YHC072A4EHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 25
7½ YHC092A4EHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 25
8½ YHC102A4EHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 25
10 YHC120A4EHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30
YHC –575/3/60 – Three Phase – High Heat
6 YHC072AWEHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 20
7½ YHC092AWEHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 15
8½ YHC102AWEHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 20
10 YHC120AWEHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.

For complete equipment / combination


Effective 1/1/06 PG-28 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-29-A — Base Unit — High Efficiency — ReliaTel™ Microprocessor Controls


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YHC –208-230/3/60 – Three Phase – Low Heat
6 YHC072A3RLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 50
7½ YHC092A3RLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 50
8½ YHC102A3RLA0000 11.4/11.01 102,000 97, 200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 50
10 YHC120A3RLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60
YHC –460/3/60 – Three Phase – Low Heat
6 YHC072A4RLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 25
7½ YHC092A4RLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 25
8½ YHC102A4RLA0000 11.4/11.01 102,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 25
10 YHC120A4RLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30
YHC –575/3/60 – Three Phase – Low Heat
6 YHC072AWRLA0000 11.4/11.01 72,000 64,800 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 20
7½ YHC092AWRLA0000 11.4/11.01 90,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 15
8½ YHC102AWRLA0000 11.4/11.01 105,000 97,200 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 20
10 YHC120AWRLA0000 11.3/10.81 116,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25
YHC –208-230/3/60 – Three Phase – Medium Heat
6 YHC072A3RMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 50
7½ YHC092A3RMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 50
8½ YHC102A3RMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 50
10 YHC120A3RMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60
YHC –460/3/60 – Three Phase – Medium Heat
6 YHC072A4RMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 25
7½ YHC092A4RMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 25
8½ YHC102A4RMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 25
10 YHC120A4RMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30
YHC –575/3/60 – Three Phase – Medium Heat
6 YHC072AWRMA0000 11.4/11.01 72,000 97,200 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 20
7½ YHC092AWRMA0000 11.4/11.01 90,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 15
8½ YHC102AWRMA0000 11.4/11.01 102,000 121,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 20
10 YHC120AWRMA0000 11.3/10.81 116,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25
YHC –208-230/3/60 – Three Phase – High Heat
6 YHC072A3RHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 34.8 50
7½ YHC092A3RHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 38.1 50
8½ YHC102A3RHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 42.3 50
10 YHC120A3RHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 48.6 60
YHC –460/3/60 – Three Phase – High Heat
6 YHC072A4RHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 17.5 25
7½ YHC092A4RHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 19.4 25
8½ YHC102A4RHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 21.4 25
10 YHC120A4RHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 25.3 30
YHC –575/3/60 – Three Phase – High Heat
6 YHC072AWRHA0000 11.4/11.01 72,000 121,500 81 41 x 53 x 89 33 x 17.5 32.13 x 17.5 915 13.5 20
7½ YHC092AWRHA0000 11.4/11.01 90,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1066 14.8 15
8½ YHC102AWRHA0000 11.4/11.01 102,000 162,000 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1100 16.6 20
10 YHC120AWRHA0000 11.3/10.81 116,000 202,500 81 47 x 53 x 89 33 x 17.5 32.13 x 17.5 1203 19.9 25
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.

For complete equipment / combination


selections and installation instructions, please PG-29 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons
(Model Digit Numbers)

Digit Description Order Number Digit Description Order Number


1-8 Main Assembly (see previous page) 19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)
9 Unit Controls No Disconnect Circuit Breaker/No Phase Monitor ....... 0
Electromechanical .................................................... E Non-Fused Disconnectt ........................................... 1
Unit Controls -ReliaTel™ Micro-processor .................. R Circuit Breakert ....................................................... 2
Phase Monitory ....................................................... 3
10 Heating Capacity Phase Monitory & Non-Fused Disconnect Switch ...... 4
Low ......................................................................... L Phase Monitory & Circuit Breaker ............................. 5
Medium .................................................................. M
High ......................................................................... H 20 Convenience Outlet
Low - Stainless Steel Heat Exchanger ....................... X No Convenience Outlet ............................................. 0
Medium - Stainless Steel Heat Exchanger .................. Y Unpowered Convenience Outlet ............................... A
High - Stainless Steel Heat Exchanger ....................... Z Powered Convenience Outlet (3 phase only)3 ........... B
11 Minor Design Sequence 21 Communications Optionsu
First Sequence ........................................................ A No Communications Interface ................................... 0
Trane Communications Interface ............................... 1
12-13 Service Sequence LonTalk® Communications Interface .......................... 2
First Sequence (Factory assigned) .......................... ✱,✱ Novar 2024 Controls ................................................. 3
14 Fresh Air Selection Novar 3051 Controls ................................................. 4
No Fresh Air ............................................................. 0 22 Refrigeration System Option
0-50% Manual Outside Air Dampere ......................... A Standard Refrigeration System4 ............................... 0
0-50% Motorized Outside Air Damper ........................ B Thermal Expansion Value (TXV)4 ............................. A
0-100% Economizer, Dry Bulb without Dehumidification (Hot Gas Reheat Coil)r .................. B
Barometric Relief2 ................................................ C
0-100% Economizer, Dry Bulb with 23 Refrigeration Controls
Barometric Relief2 ............................................... D No Refrigeration Control ........................................... 0
0-100% Economizer, Reference Enthalpy High Pressure Control6u ......................................... 1
without Barometric Relief12 .................................. E Frostat5 .................................................................. 2
0-100%Economizer, Reference Enthalpy Crankcase Heater .................................................... 3
with Barometric Relief12 ....................................... F High Pressure Control6u and Frostat5 ..................... 4
0-100%Economizer, Comparative Enthalpy High Pressure Control6u and Crankcase Heater ....... 5
without Barometric Relief 12 ................................ G Frostat5 and Crankcase Heater6 ............................. 6
0-100%Economizer, Comparative Enthalpy High Pressure Control6u, Frostat5 and
with Barometric Relief 12 ...................................... H Crankcase Heater6 .............................................. 7
15 Supply Fan/Drive Type/Motor 24 Smoke Detector7u
Standard Drive ......................................................... 0 No Smoke Detector .................................................. 0
Oversized Motor ....................................................... 1 Return Air Smoke Detector89 .................................. A
Optional Belt Drive Motor (3 phase only) .................... 2 Supply Air Smoke Detector ....................................... B
Supply and Return Air Smoke Detectors89 ............... C
16 Hinged Service Access & Filters
Standard Panels & Filters ......................................... 0 25 Monitoring Controlsu
Hinged Access Panels & Standard Filters .................. A No Monitoring Control0 ............................................ 0
Standard panels & 2" Pleated Filters .......................... B Clogged Filter Switch0 ............................................. 1
Hinged Access Panels & 2" Pleated Filters ................ C Fan Failure Switch0 ................................................. 2
Discharge Air Sensing Tube0 ................................... 3
17 Condenser Coil Protection Clogged Filter Switch and Fan Fail Switch0 ............... 4
Standard Coil ........................................................... 0 Clogged Filter Switch and Discharge
Standard Coil with Hail Guard ................................... 1 Air Sensing Tube0 ................................................ 5
Epoxy Coated Condenser Coil .................................. 2 Fan Fail Switch and Discharge Air Sensing Tube0 ..... 6
Epoxy Coated Condenser Coil with Hail Guard .......... 3 Clogged Filter and Fan Fail Switches
18 Through the Base Provisions and Discharge Air Sensing Tube0 .......................... 7
No Through the Base Provisions ............................... 0 Novar Return Air Sensorq ........................................ 8
Through the Base Electrict ...................................... A
Through the Base Gas .............................................. B
Through the Base Gas and Electricw ......................... C

1 Enthalpy control not available factory installed with electro-mechanical controls. 9 Return Air Smoke Detector cannot be ordered with Novar Controls.
2 Economizer with Barometric Relief is for downfllow configured units only. Order 0 These options are standard when ordering Novar Controls.
Economizer without Barometric Relief for horizontal configuration. Barometric relief for q This option is used when ordering Novar Controls.
horizontal configured units must be ordered as field installed accessory BAYBARM010A. w Includes gas piping and shutoff (field assembly required).
3 Requires use of Disconnect or Circuit Breaker. e The manual outside air damper will ship factory supplied within the unit, but must be field
4 Standard refrigeration metering device - short orifice. installed.
5 Frostat cannot be field installed in electro-mechanical units. r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.
6 High Pressure control is standard on 3 phase units with scroll compressors and in t Through the base electric required when ordering disconnect/circuit breaker options.
YSC036A. y Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models phase
7 Not available with BAYFRST001A High Temperature Stat accessory. monitor will be an option.
7 The return air smoke detector may not fit up or work properly on the Precedent units u Not available with electro-mechanical controls.
when used in conjunction with 3rd party accessories such as bolt on heat wheels,
economizers and power exhaust. Do not order the return air smoke detectors when
using this type of accessory.

For complete equipment / combination


Effective 1/1/06 PG-30 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons
Table PG-31-A — Accessories
Model Number Description y
Used Withy
BAYABRD001C5 .................... ReliaTel™ Options Module ...................................................... See Note8
BAYASCT0010e .................... Anti-Short-Cycle Timer ............................................................ Y*C036-060(A or E), Y*C072-120A_E
BAYBARM011A7 .................... Barometric Relief ..................................................................... Y*C072-120A
BAYBARM010A7 .................... Barometric Relief ..................................................................... Y*C036-060(A or E)
BAYCCHT010B ........................ Crankcase Heater ................................................................... YSC048-060(A or E), YSC072A1,A3, Y*C092-120A3, YHC072A1,A3
BAYCCHT011B ........................ Crankcase Heater ................................................................... YSC048-060(A or E), YSC072A4,AW, Y*C092-120A4,AW, YHC072A4,AW
BAYCCHT012A ....................... Crankcase Heater ................................................................... Y*C090A3
BAYCCHT013A ....................... Crankcase Heater ................................................................... Y*C090A4
BAYCCHT014A ....................... Crankcase Heater ................................................................... Y*C090AW
BAYCO2K001B5r ................ CO2 Sensor Kit, Wall Mounted ................................................ Y*C036-060(A or E), Y*C072-120A_R
BAYCO2K003B5r ................ CO2 Sensor Kit, Duct Mounted ................................................ Y*C036-060(A or E), Y*C072-120A_R
BAYCURB042A4 .................... Roof Curb ................................................................................ Y*C036-060(A or E)
BAYCURB043A4 .................... Roof Curb ................................................................................ Y*C072-120A
BAYDFPS003A58 ................. Clogged Filter Switch .............................................................. Y*C036-060(A or E), Y*C072-120A_R
BAYDFPS004A58 ................. Fan Failure Switch ................................................................... Y*C036-060(A or E), Y*C072-120A_R
BAYDMPR051A5 ................... 0-50% Motorized Outside Air Damper .................................... Y*C036-060(A or E)
BAYDMPR052A0 ................... 0-50% Motorized Outside Air Damper .................................... Y*C036-060(A or E)_E
BAYDMPR053Bt ................... 0-50% Manual Outside Air Damper ........................................ Y*C036-060(A or E)
BAYDMPR054A5 ................... 0-50% Motorized Outside Air Damper .................................... Y*C072-120A_R
BAYDMPR055A0 ................... 0-50% Motorized Outside Air Damper .................................... Y*C072-120A_E
BAYDMPR056Bt ................... 0-50% Manual Outside Air Damper ........................................ Y*C072-120A
BAYECON085A5 .................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C036-060(A or E)_R
BAYECON086A0 .................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C036-060(A or E)_E
BAYECON087A5 ................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C072-120A_R
BAYECON088A0 ................... 0-100% Dry Bulb Economizer without Barometric Relief ........ Y*C072-120A_E
BAYENTH005A1 .................... Reference Enthalpy Kit ............................................................ BAYECON085A, 087A
BAYENTH006A1 .................... Comparative Enthalpy Kit ........................................................ BAYECON085A, 087A
BAYENTH001A ........................ Enthalpy Control (Solid State .................................................. BAYECON086A, 088A
BAYFRST001A56 ................. High Temperature Stat ............................................................. Y*C036-060(A or E), Y*072-120A_E
BAYGARD036B ....................... Condenser Coil Hail Guard ..................................................... YSC036-060(A or E)**L,M, YHC036-048(A or E)**L,M
BAYGARD037B ....................... Condenser Coil Hail Guard ..................................................... YSC036-060(A or E)**H, YHC036-048(A or E)**H,YHC060(A or E)**L,M,H
BAYGARD040B ....................... Condenser Coil Hail Guard ..................................................... YSC072A,090A,092A,YHC072A
BAYGARD041B ....................... Condenser Coil Hail Guard ..................................................... YSC102A,120A,YHC092,102A,120A
BAYHAKT010B ........................ High Altitude Kit ....................................................................... Y*C036-060(A or E), Y*C072-120A
BAYHSDR012A ....................... High Static Drive Kit ................................................................ Y*C072A,YSC090, 092A
BAYHSMT073A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)1,(A or E)3
BAYHSMT074A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)4
BAYHSMT075A ....................... .45 HP Oversized motor kit ..................................................... Y*C036(A or E)W
BAYHSMT076A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)1,(A or E)3
BAYHSMT077A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)4
BAYHSMT078A ....................... .75 HP Oversized motor kit ..................................................... Y*C048(A or E)W
BAYHSMT079A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)1,(A or E)3
BAYHSMT080A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)4
BAYHSMT081A ....................... 1.2 HP Oversized motor kit ..................................................... Y*C060(A or E)W
BAYHSMT082A ....................... 2 HP Oversized motor kit ........................................................ Y*C072A3,A4
BAYHSMT083A ....................... 2 HP Oversized motor kit ........................................................ Y*C072AW
BAYHSMT084A ....................... 3 HP Oversized motor kit ........................................................ YSC090,092A3, A4
BAYHSMT085A ....................... 3 HP Oversized motor kit ........................................................ YSC090,092AW
BAYHSMT086A ....................... 3 HP Oversized motor kit ........................................................ Y*C102A3,A4,YHC092A3, A4
BAYHSMT087A ....................... 3 HP Oversized motor kit ........................................................ Y*C102AW,YHC092AW
BAYHSMT088A ....................... 5 HP Oversized motor kit ........................................................ Y*C120A3,A4
BAYHSMT089A ....................... 5 HP Oversized motor kit ........................................................ Y*C120AW
BAYICSI003A5q .................... Trane Communications Interface (TCI) ................................... Y*C036-060(A or E), Y*C072-120A_R
BAYKSKT255A ........................ Quick Start Kit ......................................................................... YSC048-060(A or E)1
BAYKSKT256A ........................ Quick Start Kit ......................................................................... YSC036(A or E)1
BAYLOAM020B28 ................ Evaporator Defrost Control (Frostat) ....................................... Y*C036-060(A or E)_R
BAYLPKT028B ........................ LP Conversion Kit .................................................................... Y*C036-060(A or E), Y*C072L,M,Y*C090L,092L,Y*C102L
BAYLPKT029A ........................ LP Conversion Kit .................................................................... Y*C072A**H, Y*C090,092,102A**M,H,Y*C120A**L,M,H
BAYLTCI002B5 ....................... LonTalk® Communications Interface (LCI) .............................. Y*C036-060(A or E), Y*C072-120A_R
BAYPWRX026Aw ................... Power Exhaust ........................................................................ Y*C072-120A3
BAYPWRX027Aw ................... Power Exhaust ........................................................................ Y*C072-120A4
BAYPWRX028Aw ................... Power Exhaust ........................................................................ Y*C072-120AW
BAYQACB009A49 ................ Quick Adapt Curb .................................................................... Y*C036-060(A or E)
BAYQACB010A49 ................ Quick Adapt Curb .................................................................... Y*C036-060(A or E)
BAYQACB011A49 ................ Quick Adapt Curb .................................................................... Y*C072-120A
BAYQACB012A49 ................ Quick Adapt Curb .................................................................... Y*C072-120A
BAYQACB013A49 ................ Quick Adapt Curb .................................................................... Y*C072-120A
BAYSENS016A5 .................... Temperature Sensor ................................................................ Y*C036-060(A or E), Y*C072-120A_R
BAYSERV001A5 .................... Selective Resistance Service Tester ....................................... Y*C036-060(A or E)_R
BAYSTAT0235 ........................ Remote Potentiometer ............................................................. BAYECON085A
BAYTUBE004A538 ............. Discharge Air Sensing Kit ....................................................... Y*C036-060(A or E)_R
BAYTUBE006A538 ............. Discharge Air Sensing Kit ....................................................... Y*C036-060(A or E), Y*C072-120A_R
BAYVNOR001B5r8 ............ Ventilation Override Kit ............................................................ Y*C036-060(A or E), Y*C072-120A_R
1 Kits contain all necessary parts to achieve desired level 8 BAYABRD001C is required when ordering field installed Voyager BAYCURB026B to accept Precedent 6-10 ton
of enthalpy control. accessories Clogged Filter Switch (BAYDFPS003A), Fan unit.BAYQACB011A adapts Voyager BAYCURB022B to
2 For use with ReliaTel™ microprocessor controlled units Fail Switch (BAYDFPS004A),Discharge Air Sensing Kit accept Precedent 6-10 ton unit.
only. Must be factory installed for Electromechanical (BAYTUBE004A or BAYTUBE005A) or Evaporator 0 Electromechanical controlled units only
controlled units. Defrost Control (Frostat) (BAYLOAM020B) Ventilation q Interface allows 3-10 ton units with ReliaTel™ Controls
3 Used for true discharge air sensing in both heating and Override Kit (BAYVNOR001B) unless the following to communicate with Tracer 100, Tracker, VariTrac II,
cooling. Required for supply air tempering. options are factory installed: Frostat, Smoke Detector, and is the preferred method of communication to Tracer
4 Lynn Haven Manufacturing has a No-Return policy for Clogged Filter Switch, Fan Failure Switch, Discharge Air Summit.
this roof curb. Sensing Kit. These factory installed options include w Power Exhaust cannot be used with Barometric Relief.
5 For use with ReliaTel™ controlled units only. the ReliaTel™ Options Module. Order Economizer without Barometric Relief.
6 Cannot be used in conjunction with factory installed 9 BAYQACB009A adapts Voyager BAYCURB021B to e Activated on Power on.
Smoke Detector option. accept Precedent 3 -5 ton unit. BAYQACB010A adapts r Field installed accessory. Requires an economizer.
7 Installs in ductwork for horizontal configuration. For Voyager BAYCURB022B to accept Precedent 3-5 ton t The manual outside air damper will ship factory supplied
downflow configuration, it installs in the unit's horizontal unit. BAYQACB012A adapts Voyager BAYCURB025B to within the unit, but must be field installed.
return duct. See Installer's Guide for more information. accept Precedent 6-10 ton unit. BAYQACB013A adapts y A=R-22, E=410A

For complete equipment / combination


selections and installation instructions, please PG-31 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-10 Tons

Table PG-32-A — Zone Sensors for ReliaTel™ Controlled Units


Model
Number Description Used with
BAYSENS006B ...... Single Setpoint Manual Changeover .................................... Y*C036-120A_R
BAYSENS008B ...... Dual Setpoint Manual or Auto Changeover .......................... Y*C036-120A_R
BAYSENS010B ...... Dual Setpoint Man. or Auto Change-over with System ........ Y*C036-120A_R
Function Lights
BAYSENS019C ...... Programmable Night Setback w/System Function Lights ..... Y*C036-120A_R
BAYSENS013C1 ... Room Sensor w/ Override and Cancel Buttons .................... Y*C036-120A_R
BAYSENS014C1 ... Room Sensor w/ Temp. Adjustment with Override and ........ Y*C036-120A_R
Cancel Buttons
BAYSENS017B ...... Remote Room Sensor .......................................................... BAYSENS006B,008B,010B,019C
BAYSENS032A5 ... Dual Thermistor Remote Zone Sensor ................................. Y*C036-120A_R
BAYSENS035A5 ... Digital Display Zone Sensor ................................................. Y*C036-120A_R
BAYSENS036A4 ... Wall-Mounted Humidity Zone Sensor ................................... YHC120,3,4,WR
BAYSENS037A4 ... Duct-Mounted Humidity Zone Sensor ................................... YHC120,3,4,WR
BAYMTPL003B ...... Retrofit Wall Cover Plate Kit 7.25" x 6.0" .............................. BAYSENS019C
BAYMTPL004B ...... Retrofit Wall Cover Plate Kit 4.75" x 4.75" ............................ BAYSENS006B,007B,010B,
013,014C,017B
Table PG-32-B — Thermostats
Model
Number Description Used with
BAY28X1903 ............ Locking Thermostat Cover .................................................... Room Thermostats
BAYSTAT040B2 ..... Programmable Thermostat ................................................... Y*C036-120A
TCONT200AN11AA Electronic, 1 Htg/1 CLG (non-prog) ...................................... Y*C036-090A
BAYBASE008A ....... Subbase 1-Stage Heating/Cooling ........................................ BAYSTAT040B
BAYBASE006A ....... Subbase 2-Stage Heating/Cooling ........................................ BAYSTAT040B
BAYSENS033A ....... Remote Wall Sensor ............................................................. BAYSTAT040B
BAYSENS034A ....... Remote Duct Sensor ............................................................ BAYSTAT040B
BAYSTAT008 ........... Manual 1-Stage Heating/Cooling .......................................... Y*C036-120A
BAYSTAT010 .......... Auto 2-Stage Heating/Cooling .............................................. Y*C036-120A
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.
2 Requires use of BAYBASE006A or BAYBASE008A.
3 Do not use with Programmable Thermostats.
4 For use with Dehumidification (Hot Gas Reheat) Coil Option.
5 For use with ReliaTel™ Controls only.
* Either standard or high efficiency models.
For additional Controls Information:
See ReliaTel™ and Micro Control features on PC-35 and PC-36

For complete equipment / combination


Effective 1/1/06 PG-32 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Light Commercial Gas Electrics New
Model Number Quick Reference
Table PG-33-A — Quick Reference
Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
YCD036C1L0B Micro-Proc YSC036*1RLA0000 YSC036*1RLA**000000000000
Electro-Mech YSC036*1ELA0000 YSC036*1ELA**000000000000
Medium Heat Micro-Proc YSC036*1RMA0000 YSC036*1RMA**000000000000
Electro-Mech YSC036*1EMA0000 YSC036*1EMA**000000000000
YCD036C1H0B Micro-Proc YSC036*1RHA0000 YSC036*1RHA**000000000000
Electro-Mech YSC036*1EHA0000 YSC036*1EHA**000000000000
YCD036C3L0B Micro-Proc YSC036*3RLA0000 YSC036*3RLA**000000000000
Electro-Mech YSC036*3ELA0000 YSC036*3ELA**000000000000
Medium Heat Micro-Proc YSC036*3RMA0000 YSC036*3RMA**000000000000
Electro-Mech YSC036*3EMA0000 YSC036*3EMA**000000000000
YCD036C3H0B Micro-Proc YSC036*3RHA0000 YSC036*3RHA**000000000000
Electro-Mech YSC036*3EHA0000 YSC036*3EHA**000000000000
YCD036C4L0B Micro-Proc YSC036*4RLA0000 YSC036*3RLA**000000000000
Electro-Mech YSC036*4ELA0000 YSC036*3ELA**000000000000
Medium Heat Micro-Proc YSC036*4RMA0000 YSC036*3RMA**000000000000
Electro-Mech YSC036*4EMA0000 YSC036*3EMA**000000000000
YCD036C4H0B Micro-Proc YSC036*4RHA0000 YSC036*4RHA**000000000000
Electro-Mech YSC036*4EHA0000 YSC036*4EHA**000000000000
YCH048C1L0B YCD048C1L0B Micro-Proc YSC048*1RLA0000 YSC048*1RLA**000000000000
Electro-Mech YSC048*1ELA0000 YSC048*1ELA**000000000000
Medium Heat Micro-Proc YSC048*1RMA0000 YSC048*1RMA**000000000000
Electro-Mech YSC048*1EMA0000 YSC048*1EMA**000000000000
YCH048C1H0B YCD048C1H0B Micro-Proc YSC048*1RHA0000 YSC048*1RHA**000000000000
Electro-Mech YSC048*1EHA0000 YSC048*1EHA**000000000000
YCH048C3L0B YCD048C3L0B Micro-Proc YSC048*3RLA0000 YSC048*3RLA**000000000000
Electro-Mech YSC048*3ELA0000 YSC048*3ELA**000000000000
Medium Heat Micro-Proc YSC048*3RMA0000 YSC048*3RMA**000000000000
Electro-Mech YSC048*3EMA0000 YSC048*3EMA**000000000000
YCH048C3H0B YCD048C3H0B Micro-Proc YSC048*3RHA0000 YSC048*3RHA**000000000000
Electro-Mech YSC048*3EHA0000 YSC048*3EHA**000000000000
YCH048C4L0B YCD048C4L0B Micro-Proc YSC048*4RLA0000 YSC048*4RLA**000000000000
Electro-Mech YSC048*4ELA0000 YSC048*4ELA**000000000000
Medium Heat Micro-Proc YSC048*4RMA0000 YSC048*4RMA**000000000000
Electro-Mech YSC048*4EMA0000 YSC048*4EMA**000000000000
YCH048C4H0B YCD048C4H0B Micro-Proc YSC048*4RHA0000 YSC048*4RHA**000000000000
Electro-Mech YSC048*4EHA0000 YSC048*4EHA**000000000000
YCH048CWL0B YCD048CWL0B Micro-Proc YSC048*WRLA0000 YSC048*WRLA**000000000000
Electro-Mech YSC048*WELA0000 YSC048*WELA**000000000000
Medium Heat Micro-Proc YSC048*WRMA0000 YSC048*WRMA**000000000000
Electro-Mech YSC048*WEMA0000 YSC048*WEMA**000000000000
YCH048CWH0B YCD048CWH0B Micro-Proc YSC048*WRHA0000 YSC048*WRHA**000000000000
Electro-Mech YSC048*WEHA0000 YSC048*WEHA**000000000000
NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.
* Digit 7- A=R-22, E=410A.

For complete equipment / combination


selections and installation instructions, please PG-33 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Light Commercial Gas Electrics New
Model Number Quick Reference
Table PG-34-A — Quick Reference
Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
YCH060C1L0B YCD060C1L0B Micro-Proc YSC060*1RLA0000 YSC060*1RLA**000000000000
Electro-Mech YSC060*1ELA0000 YSC060*1ELA**000000000000
Medium Heat Micro-Proc YSC060*1RMA0000 YSC060*1RMA**000000000000
Electro-Mech YSC060*1EMA0000 YSC060*1EMA**000000000000
YCH060C1H0B YCD060C1H0B Micro-Proc YSC060*1RHA0000 YSC060*1RHA**000000000000
Electro-Mech YSC060*1EHA0000 YSC060*1EHA**000000000000
YCH060C3L0B YCD060C3L0B Micro-Proc YSC060*3RLA0000 YSC060*3RLA**000000000000
Electro-Mech YSC060*3ELA0000 YSC060*3ELA**000000000000
Medium Heat Micro-Proc YSC060*3RMA0000 YSC060*3RMA**000000000000
Electro-Mech YSC060*3EMA0000 YSC060*3EMA**000000000000
YCH060C3H0B YCD060C3H0B Micro-Proc YSC060*3RHA0000 YSC060*3RHA**000000000000
Electro-Mech YSC060*3EHA0000 YSC060*3EHA**000000000000
YCH060C4L0B YCD060C4L0B Micro-Proc YSC060*4RLA0000 YSC060*4RLA**000000000000
Electro-Mech YSC060*4ELA0000 YSC060*4ELA**000000000000
Medium Heat Micro-Proc YSC060*4RMA0000 YSC060*4RMA**000000000000
Electro-Mech YSC060*4EMA0000 YSC060*4EMA**000000000000
YCH060C4H0B YCD060C4H0B Micro-Proc YSC060*4RHA0000 YSC060*4RHA**000000000000
Electro-Mech YSC060*4EHA0000 YSC060*4EHA**000000000000
YCH060CWL0B YCD060CWL0B Micro-Proc YSC060*WRLA0000 YSC060*WRLA**000000000000
Electro-Mech YSC060*WELA0000 YSC060*WELA**000000000000
Medium Heat Micro-Proc YSC060*WRMA0000 YSC060*WRMA**000000000000
Electro-Mech YSC060*WEMA0000 YSC060*WEMA**000000000000
YCH060CWH0B YCD060CWH0B Micro-Proc YSC060*WRHA0000 YSC060*WRHA**000000000000
Electro-Mech YSC060*WEHA0000 YSC060*WEHA**000000000000
YCH074C3L0B YCD074C3L0B Micro-Proc YSC072*3RLA0000 YSC072*3RLA**000000000000
Electro-Mech YSC072*3ELA0000 YSC072*3ELA**0000000000000
Medium Heat Micro-Proc YSC072*3RMA0000 YSC072*3RMA**000000000000
Electro-Mech YSC072*3EMA0000 YSC072*3EMA**000000000000
YCH074C3H0B YCD074C3H0B Micro-Proc YSC072*3RHA0000 YSC072*3RHA**000000000000
Electro-Mech YSC072*3EHA0000 YSC072*3EHA**000000000000
YCH074C4L0B YCD074C4L0B Micro-Proc YSC072*4RLA0000 YSC072*3RLA**000000000000
Electro-Mech YSC072*4ELA0000 YSC072*3ELA**000000000000
Medium Heat Micro-Proc YSC072*4RMA0000 YSC072*3RMA**000000000000
Electro-Mech YSC072*4EMA0000 YSC072*3EMA**000000000000
YCH074C4H0B YCD074C4H0B Micro-Proc YSC072*4RHA0000 YSC072*4RHA**000000000000
Electro-Mech YSC072*4EHA0000 YSC072*4EHA**000000000000
Low Heat Micro-Proc YSC072*WRLA0000 YSC072*WRLA**000000000000
Electro-Mech YSC072*WELA0000 YSC072*WELA**000000000000
Medium Heat Micro-Proc YSC072*WRMA0000 YSC072*WRMA**000000000000
Electro-Mech YSC072*WEMA0000 YSC072*WEMA**000000000000
High Heat Micro-Proc YSC072*WRHA0000 YSC072*WRHA**000000000000
Electro-Mech YSC072*WEHA0000 YSC072*WEHA**000000000000
YCH075C3L0B YCD075C3L0B Micro-Proc YHC072*3RLA0000 YHC072*3RLA**000000000000
Electro-Mech YHC072*3ELA0000 YHC072*3ELA**000000000000
Medium Heat Micro-Proc YHC072*3RMA0000 YHC072*3RMA**000000000000
Electro-Mech YHC072*3EMA0000 YHC072*3EMA**000000000000
YCH075C3H0B YCD075C3H0B Micro-Proc YHC072*3RHA0000 YHC072*3RHA**000000000000
Electro-Mech YHC072*3EHA0000 YHC072*3EHA**000000000000
YCH075C4L0B YCD075C4L0B Micro-Proc YHC072*4RLA0000 YHC072*3RLA**000000000000
Electro-Mech YHC072*4ELA0000 YHC072*3ELA**000000000000
Medium Heat Micro-Proc YHC072*4RMA0000 YHC072*3RMA**000000000000
Electro-Mech YHC072*4EMA0000 YHC072*3EMA**000000000000
YCH075C4H0B YCD075C4H0B Micro-Proc YHC072*4RHA0000 YHC072*4RHA**000000000000
Electro-Mech YHC072*4EHA0000 YHC072*4EHA**000000000000
NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.
* Digit 7- A=R-22, E=410A.

For complete equipment / combination


Effective 1/1/06 PG-34 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Light Commercial Gas Electrics New
Model Number Quick Reference
Table PG-35-A — Quick Reference
Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
YCH075CWL0B YCD075CWL0B Micro-Proc YHC072AWRHA0000 YHC072AWRHA**000000000000
Electro-Mech YHC072AWEHA0000 YHC072AWEHA**000000000000
Medium Heat Micro-Proc YHC072AWRMA0000 YHC072AWRMA**000000000000
Electro-Mech YHC072AWEMA0000 YHC072AWEMA**000000000000
YCH075CWH0B YCD075CWH0B Micro-Proc YHC072AWRLA0000 YHC072A3RLA**000000000000
Electro-Mech YHC072AWELA0000 YHC072A3ELA**000000000000
YCH090D3L0B YCD090D3L0B Micro-Proc YSC090A3RLA0000 YSC090A3RLA**000000000000
Electro-Mech YSC090A3ELA0000 YSC090A3ELA**000000000000
Medium Heat Micro-Proc YSC090A3RMA0000 YSC090A3RMA**000000000000
Electro-Mech YSC090A3EMA0000 YSC090A3EMA**000000000000
YCH090D3H0B YCD090D3H0B Micro-Proc YSC090A3RHA0000 YSC090A3RHA**000000000000
Electro-Mech YSC090A3EHA0000 YSC090A3EHA**000000000000
YCH090D4L0B YCD090D4L0B Micro-Proc YSC090A4RLA0000 YSC090A4RLA**000000000000
Electro-Mech YSC090A4ELA0000 YSC090A4ELA**000000000000
Medium Heat Micro-Proc YSC090A4RMA0000 YSC090A4RMA**000000000000
Electro-Mech YSC090A4EMA0000 YSC090A4EMA**000000000000
YCH090D4H0B YCD090D4H0B Micro-Proc YSC090A4RHA0000 YSC090A4RHA**000000000000
Electro-Mech YSC090A4EHA0000 YSC090A4EHA**000000000000
YCH090DWL0B YCD090DWL0B Micro-Proc YSC090AWRLA0000 YSC090AWRLA**000000000000
Electro-Mech YSC090AWELA0000 YSC090AWELA**000000000000
Medium Heat Micro-Proc YSC090AWRMA0000 YSC090AWRMA**000000000000
Electro-Mech YSC090AWEMA0000 YSC090AWEMA**000000000000
YCH090DWH0B YCD090DWH0B Micro-Proc YSC090AWRHA0000 YSC090AWRHA**000000000000
Electro-Mech YSC090AWEHA0000 YSC090AWEHA**000000000000
YCH091D3L0B YCD091D3L0B Micro-Proc YHC090A3RLA**000000000000
Electro-Mech YHC090A3ELA**000000000000
Medium Heat Micro-Proc YHC090A3RMA**000000000000
Electro-Mech YHC090A3EMA**000000000000
YCH091D3H0B YCD091D3H0B Micro-Proc YHC090A3RHA**000000000000
Electro-Mech YHC090A3EHA**000000000000
YCH091D4L0B YCD091D4L0B Micro-Proc YHC090A4RLA**000000000000
Electro-Mech YHC090A4ELA**000000000000
Medium Heat Micro-Proc YHC090A4RMA**000000000000
Electro-Mech YHC090A4EMA**000000000000
YCH091D4H0B YCD091D4H0B Micro-Proc YHC090A4RHA**000000000000
Electro-Mech YHC090A4EHA**000000000000
Low Heat Micro-Proc YHC090AWRLA**000000000000
Electro-Mech YHC090AWELA**000000000000
Medium Heat Micro-Proc YHC090AWRMA**000000000000
Electro-Mech YHC090AWEMA**000000000000
High Heat Micro-Proc YHC090AWRHA**000000000000
Electro-Mech YHC090AWEHA**000000000000
YCH102C3L0A YCD102C3L0A Micro-Proc YSC102A3RLA0000 YSC102A3RLA**000000000000
Electro-Mech YSC102A3ELA0000 YSC102A3ELA**000000000000
Medium Heat Micro-Proc YSC102A3RMA**000000000000
Electro-Mech YSC102A3EMA0000 YSC102A3EMA**000000000000
YCH102C3H0A YCD102C3H0A Micro-Proc YSC102A3RHA0000 YSC102A3RHA**000000000000
Electro-Mech YSC102A3EHA0000 YSC102A3EHA**000000000000
YCH102C4L0A YCD102C4L0A Micro-Proc YSC102A4RLA0000 YSC102A4RLA**000000000000
Electro-Mech YSC102A4ELA0000 YSC102A4ELA**000000000000
Medium Heat Micro-Proc YSC102A4RMA0000 YSC102A4RMA**000000000000
Electro-Mech YSC102A4EMA0000 YSC102A4EMA**000000000000
YCH102C4H0A YCD102C4H0A Micro-Proc YSC102A4RHA0000 YSC102A4RHA**000000000000
Electro-Mech YSC102A4EHA0000 YSC102A4EHA**000000000000
YCH102CWL0A YCD102CWL0A Micro-Proc YSC102AWRLA0000 YSC102AWRLA**000000000000
Electro-Mech YSC102AWELA0000 YSC102AWELA**000000000000
Medium Heat Micro-Proc YSC102AWRMA0000 YSC102AWRMA**000000000000
Electro-Mech YSC102AWEMA0000 YSC102AWEMA**000000000000
YCH102CWH0A YCD102CWH0A Micro-Proc YSC102AWRHA0000 YSC102AWRHA**000000000000
Electro-Mech YSC102AWEHA0000 YSC102AWEHA**000000000000
YCH103C3L0A YCD103C3L0A Micro-Proc YHC102A3RLA0000 YHC102A3RLA**000000000000
Electro-Mech YHC102A3ELA0000 YHC102A3ELA**000000000000
Medium Heat Micro-Proc YHC102A3RMA0000 YHC102A3RMA**000000000000
Electro-Mech YHC102A3EMA0000 YHC102A3EMA**000000000000
YCH103C3H0A YCD103C3H0A Micro-Proc YHC102A3RHA0000 YHC102A3RHA**000000000000
Electro-Mech YHC102A3EHA0000 YHC102A3EHA**000000000000
NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated model.

For complete equipment / combination


selections and installation instructions, please PG-35 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Light Commercial Gas Electrics New
Model Number Quick Reference
Table PG-36-A — Quick Reference
Precedent™ Precedent™
Voyager Horizontal Voyager Downflow Controls Ordering Number Service Model Number
YCH103C4L0A YCD103C4L0A Micro-Proc YHC102A4RLA0000 YHC102A4RLA**000000000000
Electro-Mech YHC102A4ELA0000 YHC102A4ELA**000000000000
Medium Heat Micro-Proc YHC102A4RMA0000 YHC102A4RMA**000000000000
Electro-Mech YHC102A4EMA0000 YHC102A4EMA**000000000000
YCH103C4H0A YCD103C4H0A Micro-Proc YHC102A4RHA0000 YHC102A4RHA**000000000000
Electro-Mech YHC102A4EHA0000 YHC102A4EHA**000000000000
YCH103CWL0A YCD103CWL0A Micro-Proc YHC102A4RLA0000 YHC102A4RLA**000000000000
Electro-Mech YHC102A4ELA0000 YHC102A4ELA**000000000000
Medium Heat Micro-Proc YHC102A4RMA0000 YHC102A4RMA**000000000000
Electro-Mech YHC102A4EMA0000 YHC102A4EMA**000000000000
YCH103CWH0A YCD103CWH0A Micro-Proc YHC102A4RHA0000 YHC102A4RHA**000000000000
Electro-Mech YHC102A4EHA0000 YHC102A4EHA**000000000000
YCH120C3L0A YCD120C3L0A Micro-Proc YSC120A3RLA0000 YSC120A3RLA**000000000000
Electro-Mech YSC120A3ELA0000 YSC120A3ELA**000000000000
YCH120C3M0A YCD120C3M0A Micro-Proc YSC120A3RMA0000 YSC120A3RMA**000000000000
Electro-Mech YSC120A3EMA0000 YSC120A3EMA**000000000000
YCH120B3H0E YCD120B3H0E Micro-Proc YSC120A3RHA0000 YSC120A3RHA**000000000000
Electro-Mech YSC120A3EHA0000 YSC120A3EHA**000000000000
YCH120C4L0A YCD120C4L0A Micro-Proc YSC120A4RLA0000 YSC120A4RLA**000000000000
Electro-Mech YSC120A4ELA0000 YSC120A4ELA**000000000000
YCH120C4M0A YCD120C4M0A Micro-Proc YSC120A4RMA0000 YSC120A4RMA**000000000000
Electro-Mech YSC120A4EMA0000 YSC120A4EMA**000000000000
YCH120B4H0E YCD120B4H0E Micro-Proc YSC120A4RHA0000 YSC120A4RHA**000000000000
Electro-Mech YSC120A4EHA0000 YSC120A4EHA**000000000000
YCH120CWL0A YCD120CWL0A Micro-Proc YSC120AWRLA0000 YSC120AWRLA**000000000000
Electro-Mech YSC120AWELA0000 YSC120AWELA**000000000000
YCH120CWM0A YCD120CWM0A Micro-Proc YSC120AWRMA0000 YSC120AWRMA**000000000000
Electro-Mech YSC120AWEMA0000 YSC120AWEMA**000000000000
YCH120BWH0E YCD120BWH0E Micro-Proc YSC120AWRHA0000 YSC120AWRHA**000000000000
Electro-Mech YSC120AWEHA0000 YSC120AWEHA**000000000000
YCH121C3L0A YCD121C3L0A Micro-Proc YHC120A3RLA0000 YHC120A3RLA**000000000000
Electro-Mech YHC120A3ELA0000 YHC120A3ELA**000000000000
Medium Heat Micro-Proc YHC120A3RMA0000 YHC120A3RMA**000000000000
Electro-Mech YHC120A3EMA0000 YHC120A3EMA**000000000000
YCH121C3H0A YCD121C3H0A Micro-Proc YHC120A3RHA0000 YHC120A3RHA**000000000000
Electro-Mech YHC120A3EHA0000 YHC120A3EHA**000000000000
YCH121C4L0A YCD121C4L0A Micro-Proc YHC120A4RLA0000 YHC120A4RLA**000000000000
Electro-Mech YHC120A4ELA0000 YHC120A4ELA**000000000000
Medium Heat Micro-Proc YHC120A4RMA0000 YHC120A4RMA**000000000000
Electro-Mech YHC120A4EMA0000 YHC120A4EMA**000000000000
YCH121C4H0A YCD121C4H0A Micro-Proc YHC120A4RHA0000 YHC120A4RHA**000000000000
Electro-Mech YHC120A4EHA0000 YHC120A4EHA**000000000000
YCH121CWL0A YCD121CWL0A Micro-Proc YHC120AWRLA0000 YHC120AWRLA**000000000000
Electro-Mech YHC120AWELA0000 YHC120AWELA**000000000000
Medium Heat Micro-Proc YHC120AWRMA0000 YHC120AWRMA**000000000000
Electro-Mech YHC120AWEMA0000 YHC120AWEMA**000000000000
YCH121CWH0A YCD121CWH0A Micro-Proc YHC120AWRHA0000 YHC120AWRHA**000000000000
Electro-Mech YHC120AWEHA0000 YHC120AWEHA**000000000000
NOTE: N/A indicates that an Ordering Number has not yet been set up for the indicated mode

See ReliaTel™ and Micro Control features on PC-35 and PC-36.


For complete equipment / combination
Effective 1/1/06 PG-36 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ 3-5 ton 13 SEER R-22
Packaged Gas Electrics

Standard Features:
• Trane built scroll compressors on all 3-5 ton units
• Colored and numbered wiring
• Provisions for through the Base Gas and Condensate Drain Connections
• Patented Hybrid Condenser Coil for easy cleaning
• 1" throwaway filters provided on 3-5 ton units
• Liquid Line Refrigerant Drier
• Operating Charge of R-22
• IAQ Sloped Drain Pans
• Low Ambient to 40°F on Electromechanical models
• Low Ambient to 0°F on Microprocessor models
• 5 - year Limited Compressor Warranty
• 5 - year Limited Heat Exchanger Warranty
• 1 - year Limited Parts Warranty
Featuring
A New Look for a New Century
Added Flexibility
Beveled Top
Smoother Design • Electromechanical or microprocessor controls (See page PC-35 for ReliaTel™
Small compact cabinet Control Information)
• Low, medium or high heat, single or two stage
Recessed access handles
• Convertible airflow
• Fork lift openings on three sides of unit
• Belt drive - standard or oversized motors
• We don’t prepackage options
• Choose options tailored to suit each job —pay only for what is needed
• Units ship with options installed —and within our standard ship cycle time

Factory Installed Options


• Through-the-Base — Electrical
• Convenience Outlet — Powered or unpowered
• Unit Disconnect Switch
• Smoke Detectors — Supply, return, or both
• Condenser Coil Coating
• Hinged Access Service Panels
• Discharge Air Sensor
• Fan Fail and Clogged Filter Switches
• Condenser Coil Guard — Hail Protection Quality
• Hot Gas Reheat Coil - Dehumidification
• TXV thermal expansion valve and split face evaporator coil standard
• TCI (Trane Communication Interface)
• LonTalk (Communication Interface)
• 2" Pleated Media filters
• Phase Monitor
• Frostat

The same Trane Quality and


Reliability … with added Flexibility!

For complete equipment / combination


selections and installation instructions, please PG-37 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-5 Tons 13 SEER R-22

Table PG-38-A — Base Unit — 13 SEER High Efficiency — Electromechanical


1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YHC –208-230/3/60 – Three Phase – Low Heat
3 YHC033A3ELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3ELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3ELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – Low Heat
3 YHC033A4ELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4ELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4ELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – Low Heat
3 YHC033AWELA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWELA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWELA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
YHC –208-230/3/60 – Three Phase – Medium Heat
3 YHC033A3EMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3EMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3EMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – Medium Heat
3 YHC033A4EMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4EMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4EMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – Medium Heat
3 YHC033AWEMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWEMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWEMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
YHC –208-230/3/60 – Three Phase – High Heat
3 YHC033A3EHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3EHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3EHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – High Heat
3 YHC033A4EHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4EHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
YHC063A4EHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – High Heat
3 YHC033AWEHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWEHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWEHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.

For complete equipment / combination


Effective 1/1/06 PG-38 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-5 Tons 13 SEER R-22

Table PG-39-A — Base Unit — 13 SEER High Efficiency — ReliaTel™ Microprocessor Controls
1
Heating Output1 Cabinet Shipping
Unit 3
Performance3 Cooling Capacity Dimensions (in.) Downflow Downflow Weight Max.2
Tons Ordering No. SEER/EER Capacity (Btuh) (Btuh) AFUE% H x W x L Supply Return (Ibs.) MCA* Fuse*
YHC –208-230/3/60 – Three Phase – Low Heat
3 YHC033A3RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – Low Heat
3 YHC033A4RLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4RLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4RLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – Low Heat
3 YHC033AWRLA0000 13.0 38,000 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWRLA0000 13.0 49,800 48,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWRLA0000 13.0 62,400 48,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
YHC –208-230/3/60 – Three Phase – Medium Heat
3 YHC033A3RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – Medium Heat
3 YHC033A4RMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4RMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4RMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – Medium Heat
3 YHC033AWRMA0000 13.0 38,000 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWRMA0000 13.0 49,800 64,000 81 32 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWRMA0000 13.0 62,400 64,000 81 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
YHC –208-230/3/60 – Three Phase – High Heat
3 YHC033A3RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 19.9 30
4 YHC043A3RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 22.6 35
5 YHC063A3RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 28.8 45
YHC –460/3/60 – Three Phase – High Heat
3 YHC033A4RHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 10.4 15
4 YHC043A4RHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 11.8 15
5 YHC063A4RHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 14.3 20
YHC –575/3/60 – Three Phase – High Heat
3 YHC033AWRHA0000 13.0 38,000 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 620 7.7 15
4 YHC043AWRHA0000 13.0 49,800 96,000 81 36 x 44 x 70 18 x 15.5 24 x 14 662 8.5 15
5 YHC063AWRHA0000 13.0 62,400 104,000 80 36 x 44 x 70 18 x 15.5 24 x 14 697 11.4 15
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
1 Downflow Airflow/Horizontal Airflow
2 HCAR Breaker per NEC.
3 SEER applies, 3-5 tons; EER applies 6-10 tons.

For complete equipment / combination


selections and installation instructions, please PG-39 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-5 Tons 13 SEER R-22
(Model Digit Numbers)
Digit Description Order Number Digit Description Order Number
1-8 Main Assembly (see previous page) 19 Disconnect/Circuit Breaker/Phase Monitor (3 phase only)
9 Unit Controls No Disconnect Circuit Breaker/No Phase Monitor ....... 0
Electromechanical .................................................... E Non-Fused Disconnectt ........................................... 1
Unit Controls -ReliaTel™ Micro-processor .................. R Circuit Breakert ....................................................... 2
Phase Monitory ....................................................... 3
10 Heating Capacity Phase Monitory & Non-Fused Disconnect Switch ...... 4
Low ......................................................................... L Phase Monitory & Circuit Breaker ............................. 5
Medium .................................................................. M
High ......................................................................... H 20 Convenience Outlet
No Convenience Outlet ............................................. 0
11 Minor Design Sequence Unpowered Convenience Outlet ............................... A
First Sequence ........................................................ A Powered Convenience Outlet (3 phase only)3 ........... B
12-13 Service Sequence 21 Communications Optionsu
First Sequence (Factory assigned) .......................... ✱,✱ No Communications Interface ................................... 0
14 Fresh Air Selection Trane Communications Interface ............................... 1
No Fresh Air ............................................................. 0 LonTalk® Communications Interface .......................... 2
0-50% Manual Outside Air Dampere ......................... A Novar 2024 Controls ................................................. 3
0-50% Motorized Outside Air Damper ........................ B Novar 3051 Controls ................................................. 4
0-100% Economizer, Dry Bulb without 22 Refrigeration System Option
Barometric Relief2 ................................................ C Standard Refrigeration System with
0-100% Economizer, Dry Bulb with Thermal Expansion Value ....................................... 0
Barometric Relief2 ............................................... D Dehumidification (Hot Gas Reheat Coil)r .................. B
0-100% Economizer, Reference Enthalpy
without Barometric Relief12 .................................. E 23 Refrigeration Controls
0-100%Economizer, Reference Enthalpy No Refrigeration Control ........................................... 0
with Barometric Relief12 ....................................... F High Pressure Control6u ......................................... 1
0-100%Economizer, Comparative Enthalpy Frostat5 .................................................................. 2
without Barometric Relief 12 ................................ G Crankcase Heater .................................................... 3
0-100%Economizer, Comparative Enthalpy High Pressure Control6u and Frostat5 ..................... 4
with Barometric Relief 12 ...................................... H High Pressure Control6u and Crankcase Heater ....... 5
Frostat5 and Crankcase Heater6 ............................. 6
15 Supply Fan/Drive Type/Motor High Pressure Control6u, Frostat5 and
Standard Drive ......................................................... 0 Crankcase Heater6 .............................................. 7
16 Hinged Service Access & Filters 24 Smoke Detector7u
Standard Panels & Filters ......................................... 0 No Smoke Detector .................................................. 0
Hinged Access Panels & Standard Filters .................. A Return Air Smoke Detector89 .................................. A
Standard panels & 2" Pleated Filters .......................... B Supply Air Smoke Detector ....................................... B
Hinged Access Panels & 2" Pleated Filters ................ C Supply and Return Air Smoke Detectors89 ............... C
17 Condenser Coil Protection 25 Monitoring Controlsu
Standard Coil ........................................................... 0 No Monitoring Control0 ............................................ 0
Standard Coil with Hail Guard ................................... 1 Clogged Filter Switch0 ............................................. 1
Epoxy Coated Condenser Coil .................................. 2 Fan Failure Switch0 ................................................. 2
Epoxy Coated Condenser Coil with Hail Guard .......... 3 Discharge Air Sensing Tube0 ................................... 3
18 Through the Base Provisions Clogged Filter Switch and Fan Fail Switch0 ............... 4
No Through the Base Provisions ............................... 0 Clogged Filter Switch and Discharge
Through the Base Electrict ...................................... A Air Sensing Tube0 ................................................ 5
Through the Base Gas ............................................. B Fan Fail Switch and Discharge Air Sensing Tube0 ..... 6
Through the Base Gas and Electricw ........................ C Clogged Filter and Fan Fail Switches
and Discharge Air Sensing Tube0 .......................... 7
Novar Return Air Sensorq ........................................ 8
1 Enthalpy control not available factory installed with electro-mechanical controls. 9 Return Air Smoke Detector cannot be ordered with Novar Controls.
2 Economizer with Barometric Relief is for downfllow configured units only. Order 0 These options are standard when ordering Novar Controls.
Economizer without Barometric Relief for horizontal configuration. Barometric relief for q This option is used when ordering Novar Controls.
horizontal configured units must be ordered as field installed accessory BAYBARM010A. w Includes gas piping and shutoff (field assembly required).
3 Requires use of Disconnect or Circuit Breaker. e The manual outside air damper will ship factory supplied within the unit, but must be field
4 Standard refrigeration metering device - short orifice. installed.
5 Frostat cannot be field installed in electro-mechanical units. r Requires Selection of 2" Pleated Filters (Option B or C) for Digit 16.
6 High Pressure control is standard on 3 phase units with scroll compressors and in t Through the base electric required when ordering disconnect/circuit breaker options.
YSC036A. y Phase Monitor is standard on T/Y/WSC060A3,4,W models. All other models Phase
7 Not available with BAYFRST001A High Temperature Stat accessory. Monitor is an option.
8 The return air smoke detector may not fit up or work properly on the Precedent units u Not available with electro-mechanical controls.
when used in conjunction with 3rd party accessories such as bolt on heat wheels,
economizers and power exhaust. Do not order the return air smoke detectors when
using this type of accessory.

For complete equipment / combination


Effective 1/1/06 PG-40 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-5 Tons 13 SEER R-22
Table PG-41-A — Accessories
Model Number Description Used With
BAYABRD001C5 ................... ReliaTel™ Options Module ..................................................... See Note8
BAYASCT0010w .................... Anti-Short-Cycle Timer ........................................................... YHC033-063A_E
BAYBARM010A7 ................... Barometric Relief .................................................................... YHC033-063A
BAYCCHT010B ...................... Crankcase Heater ................................................................... YHC033-063A3
BAYCCHT011B ...................... Crankcase Heater ................................................................... YHC033-063A4,AW
BAYCO2K001B5e ................ CO2 Sensor Kit, Wall Mounted ................................................ YHC033-063A_R
BAYCO2K003B5e ................ CO2 Sensor Kit, Duct Mounted ............................................... YHC033-063A_R
BAYCURB042A4 ................... Roof Curb ............................................................................... YHC033-063A
BAYDFPS003A58 ................. Clogged Filter Switch .............................................................. YHC033-063A_R
BAYDFPS004A58 ................. Fan Failure Switch .................................................................. YHC033-063A_R
BAYDMPR051A5 .................. 0-50% Motorized Outside Air Damper .................................... YHC033-063A
BAYDMPR052A0 .................. 0-50% Motorized Outside Air Damper .................................... YHC033-063A_E
BAYDMPR053Br .................. 0-50% Manual Outside Air Damper ........................................ YHC033-063A
BAYECON085A5 .................. 0-100% Dry Bulb Economizer without Barometric Relief ....... YHC033-063A_R
BAYECON086A0 .................. 0-100% Dry Bulb Economizer without Barometric Relief ....... YHC033-063A_E
BAYENTH005A1 ................... Reference Enthalpy Kit ........................................................... BAYECON085A
BAYENTH006A1 ................... Comparative Enthalpy Kit ....................................................... BAYECON085A
BAYENTH001A ...................... Enthalpy Control (Solid State .................................................. BAYECON086A
BAYFRST001A56 ................. High Temperature Stat ............................................................ YHC033,063A_R
BAYGARD036B ..................... Condenser Coil Hail Guard ..................................................... YHC033-043A**L,M
BAYGARD037B ..................... Condenser Coil Hail Guard ..................................................... YHC033-043A**H,YHC063A**L,M,H
BAYHAKT010B ...................... High Altitude Kit ...................................................................... YHC033-063A
BAYHSMT073A ..................... .45 HP Oversized motor kit ..................................................... YHC033A3
BAYHSMT074A ..................... .45 HP Oversized motor kit ..................................................... YHC033A4
BAYHSMT075A ..................... .45 HP Oversized motor kit ..................................................... YHC033AW
BAYHSMT076A ..................... .75 HP Oversized motor kit ..................................................... YHC043A3
BAYHSMT077A ..................... .75 HP Oversized motor kit ..................................................... YHC043A4
BAYHSMT078A ..................... .75 HP Oversized motor kit ..................................................... YHC043AW
BAYHSMT079A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063A3
BAYHSMT080A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063A4
BAYHSMT081A ..................... 1.2 HP Oversized motor kit ..................................................... YHC063AW
BAYICSI003A5q ................... Trane Communications Interface (TCI) ................................... YHC033-063A_R
BAYLOAM020B28 ................ Evaporator Defrost Control (Frostat) ....................................... YHC033-063A_R
BAYLPKT028B ....................... LP Conversion Kit ................................................................... YHC033-063A
BAYLTCI002B5 ...................... LonTalk® Communications Interface (LCI) .............................. YHC033-063A_R
BAYQACB009A49 ................ Quick Adapt Curb ................................................................... YHC033-063A
BAYQACB010A49 ................ Quick Adapt Curb ................................................................... YHC033-063A
BAYSENS016A5 ................... Temperature Sensor ............................................................... YHC033-063A_R
BAYSERV001A5 ................... Selective Resistance Service Tester ...................................... YHC033-063A_R
BAYSTAT0235 ....................... Remote Potentiometer ............................................................ BAYECON085A
BAYTUBE004A358 .............. Discharge Air Sensing Kit ....................................................... YHC033-063A_R
BAYTUBE006A358 .............. Discharge Air Sensing Kit ....................................................... YHC033-063A_R
BAYVNOR001B58e ............. Ventilation Override Kit ........................................................... YHC033-063A_R
1 Kits contain all necessary parts to achieve desired level 8 BAYABRD001C is required when ordering field installed 0 Electromechanical controlled units only
of enthalpy control. accessories Clogged Filter Switch (BAYDFPS003A), q Interface allows 3-10 ton units with ReliaTel™ Controls
2 For use with ReliaTel™ microprocessor controlled units Fan Fail Switch (BAYDFPS004A),Discharge Air Sensing to communicates with Tracer 100, Tracker, VariTrac II,
only. Must be factory installed for Electromechanical Kit (BAYTUBE004A or BAYTUBE005A) or Evaporator and is the preferred method of communication to Tracer
controlled units. Defrost Control (Frostat) (BAYLOAM020B) Ventilation Summit.
3 Used for true discharge air sensing in both heating and Override Kit (BAYVNOR001B) unless the following w Activated on Power on.
cooling. Required for supply air tempering. options are factory installed: Frostat, Smoke Detector, e Field installed accessory. Requires an economizer.
4 Lynn Haven Manufacturing has a No-Return policy for Clogged Filter Switch, Fan Failure Switch, Discharge Air r The manual outside air damper will ship factory supplied
this roof curb. Sensing Kit. These factory installed options include within the unit, but must be field installed.
5 For use with ReliaTel™ controlled units only. the ReliaTel™ Options Module.
6 Cannot be used in conjunction with factory installed 9 BAYQACB009A adapts Voyager BAYCURB021B to
Smoke Detector option. accept Precedent 3 -5 ton unit. BAYQACB010A adapts
7 Installs in ductwork for horizontal configuration. For Voyager BAYCURB022B to accept Precedent 3-5 ton
downflow configuration, it installs in the unit's horizontal unit. BAYQACB012A adapts Voyager BAYCURB025B to
return duct. See Installer's Guide for more information. accept Precedent 6-10 ton unit. BAYQACB013A adapts
Voyager BAYCURB026B to accept Precedent 6-10 ton
unit.BAYQACB011A adapts Voyager BAYCURB022B to
accept Precedent 6-10 ton unit.

For complete equipment / combination


selections and installation instructions, please PG-41 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Precedent™ Packaged Gas/Electric
Convertible 3-5 Tons 13 SEER R-22

Table PG-42-A — Zone Sensors for ReliaTel™ Controlled Units


Model
Number Description Used with
BAYSENS006B ...... Single Setpoint Manual Changeover .................................... YHC033-063A_R
BAYSENS008B ...... Dual Setpoint Manual or Auto Changeover .......................... YHC033-063A_R
BAYSENS010B ...... Dual Setpoint Man. or Auto Change-over with System ........ YHC033-063A_R
Function Lights
BAYSENS019C2 ... Programmable Night Setback w/System Function Lights ..... YHC033-063A_R
BAYSENS013C1 ... Room Sensor w/ Override and Cancel Buttons .................... YHC033-063A_R
BAYSENS014C1 ... Room Sensor w/ Temp. Adjustment with Override and ........ YHC033-063A_R
Cancel Buttons
BAYSENS017B ...... Remote Room Sensor .......................................................... BAYSENS006B,008B,010B,019C
BAYSENS032A6 ... Dual Thermistor Remote Zone Sensor ................................. YHC033-063A_R
BAYSENS035A6 ... Digital Display Zone Sensor ................................................. YHC033-063A_R
BAYSENS036A5 ... Wall-Mounted Humidity Zone Sensor ................................... YHC033-063A3,4,WR
BAYSENS037A5 ... Duct-Mounted Humidity Zone Sensor ................................... YHC033-063A3,4,WR
BAYMTPL003B ...... Retrofit Wall Cover Plate Kit 7.25" x 6.0" .............................. BAYSENS019C
BAYMTPL004B ...... Retrofit Wall Cover Plate Kit 4.75" x 4.75" ............................ BAYSENS006B,007B,010B,
013,014C,017B

Table PG-42-B — Thermostats


Model
Number Description Used with
BAY28X1903 ............ Locking Thermostat Cover .................................................... Room Thermostats
BAYSTAT040B2 ..... Programmable Thermostat ................................................... YHC033-063A
TCONT200AN11AA Electronic, 1 Htg/1 CLG (non-prog) ...................................... YHC033-063A
BAYBASE008A ....... Subbase 1-Stage Heating/Cooling ........................................ BAYSTAT040B
BAYBASE006A ....... Subbase 2-Stage Heating/Cooling ........................................ BAYSTAT040B
BAYSENS033A ....... Remote Wall Sensor ............................................................. BAYSTAT040B
BAYSENS034A ....... Remote Duct Sensor ............................................................ BAYSTAT040B
BAYSTAT008 ........... Manual 1-Stage Heating/Cooling .......................................... YHC033-063A
BAYSTAT010 .......... Auto 2-Stage Heating/Cooling .............................................. YHC033-063A
1 Used with Integrated ComfortTM Systems, any unit type. These sensors do not work with TCM. Consult BASD Marketing for them.
2 Requires use of BAYBASE006A or BAYBASE008A.
3 Do not use with Programmable Thermostats.
4 Use only with electromechanical unit controls.
5 For use with Dehumidification (Hot Gas Reheat) Coil Option.
6 For use with ReliaTel™ Controls only.
* Either standard or high efficiency models.
For additional Controls Information:
See ReliaTel™ and Micro Control features on PC-35 and PC-36.

For complete equipment / combination


Effective 1/1/06 PG-42 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Gas/Electric with ReliaTel™
Controls 12½ through 15 Tons
• EER up to 11.5 • “Quick-Access” doors and single side
• Trane built scroll compressors access make servicing much faster for
• Scroll compressors on all models lower maintenance costs
• ReliaTel™ control features are listed on • Quick-adjust idler arm pulley. Adjust belt
page PC-35 tension, change belts, adjust airflow
• Built-in anti-short cycle timer, time delay quickly
relay and minimum on time controls • High efficiency gas heat with hot surface
• Low Ambient to 0°F standard ignition for low heating energy costs, low
• High efficiency drum and tube heat maintenance and high reliability
exchanger • IAQ sloped condensate drain pans
• Color coded and numbered wiring • 5-year limited compressor warranty
• Two inch filters on both YCH and YCD to (12½-15 tons)
clean air and keep coil maintenance low • 5-year limited heat exchanger warranty
YCD — Downflow • Simple U-shaped airflow pattern results in (12½-15 tons)
very low airside energy requirement • 1 year limited parts warranty

Table PG-43-A — Downflow — Micro Control Unit


Cooling Heating Output Shipping Max Fuse Size
Unit Power Supply Performance Capacity Capacity Dimensions (in.) Weight 1 Max
or1 Downflow
Tons Model No. Volts/Phase/Hz EER (3Ø) (Btuh) (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker* Roofcurb
121/2 YCD150D3L0B 208-230/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 63 80 BAYCURB026B
121/2 YCD150D4L0B 460/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 33 40 BAYCURB026B
121/2 YCD150DWL0B 575/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 26 30 BAYCURB026B
121/2 YCD150D3H0B 208-230/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 63 80 BAYCURB026B
121/2 YCD150D4H0B 460/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 33 40 BAYCURB026B
121/2 YCD150DWH0B 575/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 26 30 BAYCURB026B
121/2 YCD151C3L0B 208-230/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 64 80 BAYCURB026B
121/2 YCD151C4L0B 460/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 31 40 BAYCURB026B
121/2 YCD151CWL0B 575/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 25 30 BAYCURB026B
121/2 YCD151C3H0B 208-230/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 64 80 BAYCURB026B
121/2 YCD151C4H0B 460/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 31 40 BAYCURB026B
121/2 YCD151CWH0B 575/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 25 30 BAYCURB026B
15 YCD180B3L0H 208-230/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 78 90 BAYCURB026B
15 YCD180B4L0H 460/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 39 50 BAYCURB026B
15 YCD180BWL0H 575/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 31 40 BAYCURB026B
15 YCD180B3H0H 208-230/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 78 90 BAYCURB026B
15 YCD180BWH0H 575/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 31 40 BAYCURB026B
15 YCD180B4H0H 460/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 39 50 BAYCURB026B
15 YCD181C3L0C 208-230/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 74 90 BAYCURB027B
15 YCD181C4L0C 460/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 36 50 BAYCURB027B
15 YCD181CWL0C 575/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 29 40 BAYCURB027B
15 YCD181C3H0C 208-230/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 74 90 BAYCURB027B
15 YCD181C4H0C 460/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 36 50 BAYCURB027B
15 YCD181CWH0C 575/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 29 40 BAYCURB027B

Unit Supply Return Curb Size Roof Opening


Model No. 23
Downflow W x L23 23
Downflow W x L23 H x W x L2424 23
W x L23
YC❋150,151, 180 289/16 x 551/2 207/8 x 63 141/16 x 6615/16 x 1021/4 621/2 x 731/2
YC❋181 289/16 x 691/2 221/4 x 77 141/16 x 8015/16 x 1171/8 761/2 x 81
Note: L = Low Heat H = High Heat in ninth digit
1 HACR Type Circuit Breaker per NEC.
2 Dimensions are in inches. See Outline Dimensions.
3 Interior Dimension.
4 Measurement Includes Curb Flange.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please PG-43 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Gas/Electric with ReliaTel™
Controls 17½ through 25 Tons
• Built-in anti-short cycle timer, time delay relay • High efficiency gas heat with hot surface
and minimum on time controls ignition for low heating energy costs, low
• Low Ambient to 0°F standard maintenance and high reliability
• High efficiency drum and tube heat exchanger • IAQ sloped condensate drain pans
• Color coded and numbered wiring • 5-year limited compressor warranty
• Two inch filters on both YCH and YCD to clean (17½ tons)
air and keep coil maintenance low • 1-year limited compressor warranty
• Simple U-shaped airflow pattern results in very (20 and 25 tons)
low airside energy requirement • 5-year limited heat exchanger warranty
• “Quick-Access” doors and single side access (17½ tons)
YCD — Downflow make servicing much faster for lower • 1-year limited heat exchanger warranty (20
• EER up to 11.5 maintenance costs and 25 tons)
• Scroll compressors on all units • Quick-adjust idler arm pulley. Adjust belt • 1 year limited parts warranty
• ReliaTel™ control features are listed on page tension, change belts, adjust airflow quickly
PC-35
Table PG-44-A — Downflow — Micro Control Unit
Cooling Heating Output Shipping Max Fuse Size
Unit Power Supply Performance Capacity Capacity Dimensions (in.) Weight 1 Max
or1 Downflow
Tons Model No. Volts/Phase/Hz EER (3Ø) (Btuh) (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker* Roofcurb
171/2 YCD210C3L0E 208-230/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 88 100 BAYCURB026B
171/2 YCD210C4L0E 460/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 44 50 BAYCURB026B
171/2 YCD210CWL0E 575/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 35 45 BAYCURB026B
171/2 YCD210C3H0E 208-230/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 88 100 BAYCURB026B
171/2 YCD210C4H0E 460/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 44 50 BAYCURB026B
171/2 YCD210CWH0E 575/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 35 45 BAYCURB026B
171/2 YCD211C3L0C 208-230/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 91 110 BAYCURB027B
171/2 YCD211C4L0C 460/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 44 60 BAYCURB027B
171/2 YCD211CWL0C 575/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 35 45 BAYCURB027B
171/2 YCD211C3H0C 208-230/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 91 110 BAYCURB027B
171/2 YCD211C4H0C 460/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 44 60 BAYCURB027B
171/2 YCD211CWH0C 575/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 35 45 BAYCURB027B
20 YCD240B3L0J 208-230/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 100 125 BAYCURB027B
20 YCD240B4L0J 460/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 50 60 BAYCURB027B
20 YCD240BWL0J 575/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 40 45 BAYCURB027B
20 YCD240B3H0J 208-230/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 100 125 BAYCURB027B
20 YCD240B4H0J 460/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 50 60 BAYCURB027B
20 YCD240BWH0J 575/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 40 45 BAYCURB027B
20 YCD241C3L0C 208-230/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 99 125 BAYCURB027B
20 YCD241C4L0C 460/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 50 60 BAYCURB027B
20 YCD241CWL0C 575/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 40 50 BAYCURB027B
20 YCD241C3H0C 208-230/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 99 125 BAYCURB027B
20 YCD241C4H0C 460/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 50 60 BAYCURB027B
20 YCD241CWH0C 575/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 40 50 BAYCURB027B
25 YCD300B3L0H 208-230/3/60 9.7 290,000 203,000 54 x 855/16 x 1225/16 2541 118 150 BAYCURB027B
25 YCD300B4L0H 460/3/60 9.7 290,000 203,000 54 x 855/16 x 1225/16 2541 58 70 BAYCURB027B
25 YCD300BWL0H 575/3/60 9.7 290,000 203,000 54 x 855/16 x 1225/16 2541 46 50 BAYCURB027B
25 YCD300B3H0H 208-230/3/60 9.7 290,000 324,000 54 x 855/16 x 1225/16 2541 118 150 BAYCURB027B
25 YCD300B4H0H 460/3/60 9.7 290,000 324,000 54 x 855/16 x 1225/16 2541 58 70 BAYCURB027B
25 YCD300BWH0H 575/3/60 9.7 290,000 324,000 54 x 855/16 x 1225/16 2541 46 50 BAYCURB027B
25 YCD301C3L0C 208-230/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 120 150 BAYCURB027B
25 YCD301C4L0C 460/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 58 70 BAYCURB027B
25 YCD301CWL0C 575/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 47 60 BAYCURB027B
25 YCD301C3H0C 208-230/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 120 150 BAYCURB027B
25 YCD301C4H0C 460/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 58 70 BAYCURB027B
25 YCD301CWH0C 575/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 47 60 BAYCURB027B
Unit Supply Return Curb Size Roof Opening
Model No. 23
Downflow W x L23 23
Downflow W x L23 H x W x L2424 23
W x L23
9 1 7 1 15 1
YC❋210 28 /16 x 55 /2 20 /8 x 63 14 /16 x 66 /16 x 102 /4 621/2 x 731/2
YC❋211, 240, 241, 300 289/16 x 691/2 221/4 x 77 141/16 x 8015/16 x 1171/8 761/2 x 81
Note: L = Low Heat H = High Heat in ninth digit
1 HACR Type Circuit Breaker per NEC.
2 Dimensions are in inches. See Outline Dimensions.
3 Interior Dimension.
4 Measurement Includes Curb Flange.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


Effective 1/1/06 PG-44 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Gas/Electric with ReliaTel™
Controls 12½ through 15 Tons
• EER up to 11.5 lower maintenance costs
• Scroll compressors on all units • Quick-adjust idler arm pulley. Adjust
• ReliaTel™ control features are listed on belt tension, change belts, adjust
page PC-35 airflow quickly
• Built-in anti-short cycle timer, time delay • High efficiency gas heat with hot surface
relay and minimum on time controls ignition for low heating
• Low Ambient to 0°F standard energy costs, low maintenance
• High efficiency drum and tube heat and high reliability
exchanger • IAQ sloped condensate drain pans
• Color coded and numbered wiring • 5-year limited compressor warranty
• Two inch filters on both YCH and YCD to (12½-15 tons)
clean air and keep coil maintenance low • 5-year limited heat exchanger warranty
• Simple U-shaped airflow pattern results in (12½-15 tons)
YCH — Horizontal very low airside energy requirement • 1 year limited parts warranty
• “Quick-Access” doors and single side
access make servicing much faster for

Table PG-45-A — Horizontal — Micro Control Unit


Shipping Max Fuse Size
Unit Power Supply Performance Cooling Heating Output Dimensions (in.) Weight 1 Max
or1
Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) Capacity (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker*
121/2 YCH150D3L0B 208-230/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 63 80
121/2 YCH150D4L0B 460/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 33 40
121/2 YCH150DWL0B 575/3/60 9.6 150,000 122,000 501/8 x 715/16 x 1075/16 1826 26 30
121/2 YCH150D3H0B 208-230/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 63 80
121/2 YCH150D4H0B 460/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 33 40
121/2 YCH150DWH0B 575/3/60 9.6 150,000 203,000 501/8 x 715/16 x 1075/16 1826 26 30
121/2 YCH151C3L0B 208-230/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 64 80
121/2 YCH151C4L0B 460/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 31 40
121/2 YCH151DWL0B 575/3/60 11.3 154,000 122,000 501/8 x 715/16 x 1075/16 1915 25 30
121/2 YCH151C3H0B 208-230/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 64 80
121/2 YCH151C4H0B 460/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 31 40
121/2 YCH151DWH0B 575/3/60 11.3 154,000 203,000 501/8 x 715/16 x 1075/16 1915 25 30
15 YCH180B3L0H 208-230/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 78 90
15 YCH180B4L0H 460/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 39 50
15 YCH180BWL0H 575/3/60 9.7 182,000 203,000 501/8 x 715/16 x 1075/16 2033 31 40
15 YCH180B3H0H 208-230/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 78 90
15 YCH180B4H0H 460/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 39 50
15 YCH180BWH0H 575/3/60 9.7 182,000 284,000 501/8 x 715/16 x 1075/16 2033 31 40
15 YCH181C3L0C 208-230/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 74 90
15 YCH181C4L0C 460/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 36 50
15 YCH181CWL0C 575/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 29 40
15 YCH181C3H0C 208-230/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 74 90
15 YCH181C4H0C 460/3/60 11.5 189,000 284,000 54 x 855/16 x 1225/16 2464 36 50
15 YCH181CWH0C 575/3/60 11.5 189,000 203,000 54 x 855/16 x 1225/16 2464 29 40
Unit Supply Return
Model No. 23
Horizontal H x W23 23
Horizontal H x W23
YC❋150C 417/16 x 221/2 417/16 x 173/16
YC❋151, 180 421/2 x 261/2 421/2 x 249/16
YC❋181 467/16 x 261/2 467/16 x 279/16
Note: L = Low Heat H = High Heat in ninth digit
1 HACR Type Circuit Breaker per NEC.
2 Dimensions are in inches. See Outline Dimensions.
3 Interior Dimension.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.

For complete equipment / combination


selections and installation instructions, please PG-45 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Gas/Electric with ReliaTel™
Controls 17½ through 25 Tons
• Built-in anti-short cycle timer, time delay relay • High efficiency gas heat with hot surface
and minimum on time controls ignition for low heating energy costs, low
• Low Ambient to 0°F standard maintenance and high reliability
• High efficiency drum and tube heat exchanger • IAQ sloped condensate drain pans
• Color coded and numbered wiring • 5-year limited compressor warranty
• Two inch filters on both YCH and YCD to clean (17½ tons)
air and keep coil maintenance low • 1-year limited compressor warranty
• Simple U-shaped airflow pattern results in very (20 and 25 tons)
low airside energy requirement • 5-year limited heat exchanger warranty
YCH — Horizontal • “Quick-Access” doors and single side access (17½ tons)
make servicing much faster for lower • 1-year limited heat exchanger warranty
• EER up to 11.5 maintenance costs (20 and 25 tons)
• Scroll compressors on all units • Quick-adjust idler arm pulley. Adjust belt • 1 year limited parts warranty
• ReliaTel™ control features are listed on page tension, change belts, adjust airflow quickly
PC-35

Table PG-46-A — Horizontal — Micro Control UnitMax Fuse Size


Shipping Max Fuse Size
Unit Power Supply Performance Cooling Heating Output Dimensions (in.) Weight 1 Max
or1
Tons Model No. Volts/Phase/Hz EER (3Ø) Capacity (Btuh) Capacity (Btuh) H x W x L (Ibs.) MCA* Circuit Breaker*
171/2 YCH210C3L0E 208-230/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 88 110
171/2 YCH210C4L0E 460/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 44 50
171/2 YCH210CWL0E 575/3/60 9.6 210,000 203,000 501/8 x 715/16 x 1075/16 2189 35 45
171/2 YCH210C3H0E 208-230/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 88 110
171/2 YCH210C4H0E 460/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 44 50
71/2 YCH210CWH0E 575/3/60 9.6 210,000 284,000 501/8 x 715/16 x 1075/16 2189 35 45
171/2 YCH211C3L0C 208-230/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 91 110
171/2 YCH211C4L0C 460/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 44 60
171/2 YCH211CWL0C 575/3/60 11.0 220,000 203,000 54 x 855/16 x 1225/16 2547 35 45
171/2 YCH211C3H0C 208-230/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 91 110
171/2 YCH211C4H0C 460/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 44 60
171/2 YCH211CWH0C 575/3/60 11.0 220,000 284,000 54 x 855/16 x 1225/16 2547 35 45
20 YCH240B3L0J 208-230/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 100 125
20 YCH240B4L0J 460/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 50 60
20 YCH240BWL0J 575/3/60 9.5 242,000 203,000 54 x 855/16 x 1225/16 2547 40 45
20 YCH240B3H0J 208-230/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 100 125
20 YCH240B4H0J 460/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 50 60
20 YCH240BWH0J 575/3/60 9.5 242,000 324,000 54 x 855/16 x 1225/16 2547 40 45
20 YCH241C3L0C 208-230/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 99 125
20 YCH241C4L0C 460/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 50 60
20 YCH241CWL0C 575/3/60 10.6 268,000 203,000 54 x 855/16 x 1225/16 2645 40 50
20 YCH241C3H0C 208-230/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 99 125
20 YCH241C4H0C 460/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 50 60
20 YCH241CWH0C 575/3/60 10.6 268,000 324,000 54 x 855/16 x 1225/16 2645 40 50
25 YCH300B3L0H 208-230/3/60 9.3 290,000 203,000 54 x 855/16 x 1225/16 2541 118 150
25 YCH300B4L0H 460/3/60 9.3 290,000 203,000 54 x 855/16 x 1225/16 2541 58 70
25 YCH300BWL0H 575/3/60 9.3 290,000 203,000 54 x 855/16 x 1225/16 2541 46 50
25 YCH300B3H0H 208-230/3/60 9.3 290,000 324,000 54 x 855/16 x 1225/16 2541 118 150
25 YCH300B4H0H 460/3/60 9.3 290,000 324,000 54 x 855/16 x 1225/16 2541 58 70
25 YCH300BWH0H 575/3/60 9.3 290,000 324,000 54 x 855/16 x 1225/16 2541 46 50
25 YCH301C3L0C 208-230/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 120 150
25 YCH301C4L0C 460/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 58 70
25 YCH301CWL0C 575/3/60 10.4 300,000 203,000 54 x 855/16 x 1225/16 2650 47 60
25 YCH301C3H0C 208-230/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 120 150
25 YCH301C4H0C 460/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 58 70
25 YCH301CWH0C 575/3/60 10.4 300,000 324,000 54 x 855/16 x 1225/16 2650 47 60
Unit Supply Return
Model No. 23
Horizontal H x W23 23
Horizontal H x W23
YC❋ 210 421/2 x 261/2 421/2 x 249/16
YC❋211, 240, 241, 300 467/16 x 261/2 467/16 x 279/16
Note: L = Low Heat H = High Heat in ninth digit
1 HACR Type Circuit Breaker per NEC.
2 Dimensions are in inches. See Outline Dimensions.
3 Interior Dimension.
* Information subject to change. Please confirm with current Product Data/Service Facts for current factory production.
For complete equipment / combination
Effective 1/1/06 PG-46 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged
Gas/Electric with ReliaTel™
Controls12½ through 25 Tons
Table PG-47-A —Factory Installed Accessories12 For Complete list of all Factory Installed Options, please refer to the FIOPS
section of this book.
Digit Description Order Number Used With
1-9 Main Assembly (see previous page)
10 Factory Installed Options
No Options 0 YC*150-301
Downflow Economizer3 A YCD150-301
Oversized Motor B YC*150-241
Downflow Economizer and Oversized Motor3 C YCD150-241
Trane Communications Interface (TCI)4 F YC*150-301
Downflow Economizer TCI34 G YCD150-301
TXV/Face - Split Evaporator H YCD151, 181, 211, 241, 301
Oversized Motor and TXV/Face -Split Evaporator J YCD151, 181, 211, 241
Downflow Economizer, Oversized Motor and TXV/Face K YCD151, 181, 211, 241
Split Evaporator3
Downflow Economizer with TXV/Face - Split Evaporator3 L YCD151, 181, 211, 241, 301
Reheat Coil5 M YCD151, 181, 241
Downflow Economizer with Reheat Coil35 N YCD151, 181, 241
Oversized Motor and Reheat Coil5 P YCD151, 181, 241
Downflow Economizer, Oversized Motor and R YCD151, 181, 241
Reheat Coil 35
11-12 Minor Design and Service Sequence **
1 Price includes accessory and factory installation.
2 Four (4) week shipping approximately.
3 Some field set up required.
4 TCI is for use with non-VariTrac systems and VariTrac systems.
5 All 10th digit model numbers including reheat coil (M,N,P,R) require additional factory installed options; ReliaTel™ options module (FIYABRD002B), Frostat
(FIYLOAM023A), and 2" pleated filters (FIYPLTD001A, 002A, or 003A refer to FIOPS section for appropriate model number usage). For these or any Factory Installed
Options not included in 10th digit model number, digits 1-3 must be YFD.

For complete equipment / combination


selections and installation instructions, please PG-47 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Packaged Gas/Electric
with ReliaTel™ Controls
12½ through 25 Tons Accessories
Table PG-48-A — Field Installed Accessories For complete list of of All Factory Installed Options refer to FIOPS section of this book.
Model Number Description Used With
BAYABRD002Bq ........ ReliaTel™ Options Module ................................................ YCD/YCH150-301
BAYCO2K002Bw ........ CO2 Sensor Wall Mounted ................................................. YC*150-301 w/Economizer
BAYCO2K004Bw ........ CO2 Sensor Duct Mounted ................................................ YC*150-301 w/Economizer
BAYCURB026B67 ..... Downflow Only Roof Curb ................................................. YCD150D, 151C, 180B, 210C
BAYCURB027B67 ..... Downflow Only Roof Curb ................................................. YCD181C, 211-301
BAYDFPS005A9q ...... Clogged Filter Switch ........................................................ YCD/YCH (12½-25 Tons)
BAYDFPS006A9q ...... Fan Failure Switch ............................................................. Economizers/0-50% Motorized Outside Air Dampers
BAYDMPR029C .......... 0-25% Manual Outside Air Damper ................................... YCD/YCH (12½-25 Tons)
BAYDMPR057A .......... 0-50% Motorized Outside Air Damper ............................... YCD/YCH150D, 151C, 180B, 210C
BAYDMPR058A .......... 0-50% Motorized Outside Air Damper ............................... YCD/YCH181, 211-301
BAYECON089Aq ........ Downflow Economizer with Barometric Relief ................... YCD150D, 151C, 180B, YCD210C
BAYECON090Aq ........ Downflow Economizer with Barometric Relief ................... YCD181C, 211, 240B, 241C, 300B, 301C
BAYECON091A .......... Horizontal Economizer ...................................................... YCH150D, 151C, 180B, YCH210C
BAYECON092A .......... Horizontal Economizer ...................................................... YCH181C, 211-301
BAYENTH007A12 .... Reference Enthalpy Kit ...................................................... All BAYECON089A-092A
BAYENTH008A123 .. Comparative Enthalpy Kit ................................................. All BAYECON089A-092A
BAYFRST003A ........... High Temperature Stat ...................................................... YCD/YCH150D
BAYGARD043Bq ........ Tool-less Hail Guard .......................................................... YC*150D
BAYGARD044Bq ........ Tool-less Hail Guard .......................................................... YC*151C, 180B, 210C
BAYGARD045Aq ........ Tool-less Hail Guard .......................................................... YC*181C, 211C, 240B,241C, 301C
BAYGARD047Aq ........ Tool-less Hail Guard .......................................................... YC*300B
BAYHSDR002B4 ....... High Static Drive ................................................................ YCD/YCH151C
BAYHSDR005B4 ....... High Static Drive ................................................................ YCD/YCH150D,180B, 211C, 240B, 241B
BAYHSDR010A ........... High Static Drive ................................................................ YCD/YCH300B, 301C
BAYHSDR011A ........... High Static Drive ................................................................ YCD/YCH181C
BAYHSMT039B4q .... 5 HP Oversized Motor Kit .................................................. YCD/YCH150D,151C, 180B
BAYHSMT040Bq ........ 5 HP Oversized Motor Kit .................................................. YCD/YCH150DW
BAYHSMT042A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*211C, 240B, 241CW
BAYHSMT055B4q .... 5HP Oversized Motor Kit ................................................... YCD/YCH181C
BAYHSMT059A5q .... 7-1/2HP Oversized Motor Kit (230V) ................................. YCD/YCH210C
BAYHSMT060A5q .... 7-1/2HP Oversized Motor Kit (460V) ................................. YCD/YCH210C
BAYHSMT061A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*210CW
BAYHSMT072A5q .... 7-1/2HP Oversized Motor Kit (575V) ................................. YC*181CW
BAYHSMT098A5q ..... 7-1/2HP Oversized Motor Kit .............................................. YC*211,240,241C3
BAYHSMT099A5q ..... 7-1/2HP Oversized Motor Kit .............................................. YC*211,240,241C4
BAYICSI004B0e .......... Trane Comunications Interface, Comm 3/4 (TCI) ................... YC*150-301
BAYLOAM023A9 ......... Evaporator Defrost Control ................................................... YCD150-301
BAYLPKT018A ............ LP Conversion Kit .............................................................. YCD/YCH150D,151-301C
BAYLSDR004A5 ....... Low Static Drive ................................................................. YCD/YCH210C
BAYLSDR002A5 ....... Low Static Drive ................................................................. YCD/YCH300B, 301C
BAYLTCI003B0 ........... LonTalk® Communications Interface (LCI) ......................... YC*150-301
BAYPWRX029A .......... Power Exhaust for 230 volt units ....................................... BAYECON062-089A,063-090A,065-091A,066-092A (YCD150D, 151-301C)
BAYPWRX030A .......... Power Exhaust for 460 volt units ....................................... BAYECON062-089A,063-090A,065-091A,066-092A (YCD150D, 151-301C)
BAYPWRX031A .......... Power Exhaust for use with Downflow Economizer(575V) ........ YCD150DW
BAYSENS016A ........... Temperature Sensor .......................................................... YCD/YCH (12½-25 Tons)
BAYSERV001A ........... Selective Resistance Service Tester ................................. YCD/YCH (12½-25 Tons)
BAYSTAT0237 ........... Remote Potentiometer ....................................................... All BAYECON089-92A
BAYTUBE008A9q ...... Discharge Air Sensing Kit .................................................. YCD150D-301
BAYTUBE009A9q ...... Discharge Air Sensing Kit .................................................. YCH150-301
BAYVNOR002B9 ........ Ventilation Override Kit ...................................................... YCD/YCH150-301 w/Reliatel™ Options Module
Table PG-48-B — Zone Sensors
BAYMTPL003B ........... Retrofit Wall Cover Plate Kit (71/4" x 6") ............................................. BAYSENS019C
BAYMTPL004B ........... Retrofit Wall Cover Plate Kit (43/4" x 43/4") .......................................... BAYSENS006B, 008B, 010B, 017B, 013C, 014C
BAYSENS006B ........... Single Setpoint Manual Changeover ................................................. YC*150-301
BAYSENS008B ........... Dual Setpoint Manual or Auto Changeover ....................................... YC*150-301
BAYSENS010B ........... Dual Setpoint Man. or Auto Changeover with Sys. Funct. Light ......... YC*150-301
BAYSENS013C8 ....... Room Sensor with Override Button ................................................... YC*150-301
BAYSENS014C8 ....... Room Sensor with Temperature Adjustment and Override .............. YC*150-301
BAYSENS017B ........... Remote Room Sensor ....................................................................... BAYSENS006B, 008B, 010B, 019C
BAYSENS019C ........... Programmable Night Setback with System Function Lights .............. YC*150-301
BAYSENS032A0 ........ Dual Thermistor Remote Zone Sensor .............................................. YC*150-301
BAYSENS035A0 ........ Digital Display Zone Sensor ............................................................... YC*150-300
BAYSENS036A ........... Wall-Mounted Humidity Sensor ......................................................... YFD151,181,241 (with Reheat)
BAYSENS037A ........... Duct-Mounted Humidity Sensor ......................................................... YFD151,181,241 (with Reheat)
1 Kit contains all necessary parts to achieve desired level of Enthalpy Control. 8 Used with Integrated Comfort SystemsTM any unit type. These sensors do not work with
2 Reference Enthalpy senses outside temperature/humidity and inside supply air only. TCM. Consult BASD Marketing for them.
3 Comparative Enthalpy senses outside temperature/humidity and inside supply and 9 BAYABRD002 is required when ordering BAYDFPS005A or 006A, BAYTUBE008A or
return air. 009A and BAYLOAM023A or BAYVNOR002B.
4 High static drive and oversized motors are mutually exclusive, Do Not Combine. 0 Functional only with ReliaTel™ controls.
5 Low static drive and oversized motors are mutually exclusive, Do Not Combine. q Field or factory installed option.
6 See Accessory IOM for operational characteristics. * Either horizontal or downflow models
7 Clarksville Manufacturing has a no-return policy for this roof curb. w Field installed accessory. Requires an economizer.
e Interface allows a unit with ReliaTel™ Controls to communicate with Tracer 100,
See ReliaTel™ and Micro Control features on PC-35 and PC-36. Tracker, VariTrac II, and is the preferred method of communication to Tracer Summit.

For complete equipment / combination


Effective 1/1/06 PG-48 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Voyager™ Packaged Unit Accessories
121/2 through 25 Tons

12 1/2 – 25 Ton Packaged Gas/


Electric, Electric/Electric and Heat
Pump

Factory Supplied
Accessories
A Unit
YCD/H, TCD/H, WCD/H
G Coil Guard (3-7 1/2 Ton)
(BAYGARD)
E Economizer (Downflow and
Horizontal) (BAYECON)
D Fresh Air Damper (BAYDMPR)
Manual (3-25 Ton) (0-25%)
Motorized (5-25 Ton Only) (0-50%)
S Sensor/Thermostat

C Curb (BAYCURB)

QA Quick Adapt Curb...Field Supplied


(8 1/2-25 Ton Only) (BAYCURB)
PE Power Exhaust (BAYPWRX)
(6 1/4-25 Ton Only) (BAYPWRX)

For complete equipment / combination


selections and installation instructions, please PG-49 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Voyager™ Factory Installed Options
Commercial Packaged Units 12½ through 25 Tons

Trane offers a variety of factory installed options (FIOPS) for the light commercial packaged rooftop product line. These options
are in addition to the standard factory installed options, i.e., downflow economizer and oversized motors.

Black Epoxy Coated Condenser Coil – Black Epoxy coil protection is a fac- Through the Base Electrical with Disconnect Switch – Factory installed 3-
tory-applied, thermoset vinyl coating that is bonded to the aluminum fin stock pole, molded case disconnect switch with provisions for through the base electri-
prior to the fin stamping process. The pre-coated coils are an economical option cal connections are available. The disconnect switch will be installed in the unit in
for protection in mildly corrosive environments. a water tight enclosure with access through a swinging door. Factory wiring will
be provided from the switch to the unit high voltage terminal block. The switch
Dehumidification Option – The dehumidification (hot gas reheat) option shall will be UL/CSA agency recognized. Note: The disconnect switch
be a factory-installed option that provides increased dehumidification. The will be sized per NEC and UL guidelines but will not be used in place of unit
option shall consist of a hot-gas reheat coil located on the leaving air side of the overcurrent protection.
evaporator coil prepiped and circuited. The option shall be equipped with
crankcase heater(s), low pressure switch(es), Frostat™, and a thermostatic This option is available for all 230, 460 and 575 volt, 3-phase downflow 12½ – 25
expansion valve(s) (TXV) as standard. ton models. Either a Circuit Breaker or a Disconnect Switch (not both) must be
ordered when ordering the Through the Base Electrical option.
Differential Pressure Switches – A dedicated differential pressure switch is
available to achieve active fan failure indication and/or clogged filter indication. Through the Base Gas Piping – With this option, provision will
These indications will be registered on a zone sensor with status indication be made in the unit for installing through the base gas piping. The option will
lights. This option is available for all 12½ – 25 ton models. have all piping necessary including a pre-assembled, black steel, manual gas
shut-off valve, elbows and union. The manual shut-off valve shall include a 1/8
Electric Heaters – Factory installed and wired electric heaters inch NPT pressure tap. This assembly will require minor field labor to install.
are available for all 230, 460, and 575 volt 3-phase horizontal and downflow This option is available for all 12½ – 25 ton downflow gas/electric units, and can
12½ – 25 ton models. If ordering the Through the Base Electrical option with an only be ordered when the Through the Base Electrical Option with Disconnect or
Electric Heater, the heater must be factory installed. Circuit Breaker is ordered.
High Efficiency Motors – Available with efficiency ratings from 86.5 up to 91.0. Thermal Expansion Valve (TXV) and Face Split Evaporator – All units have a
Check unit specifications for specific motor size per unit model. short orifice refrigerant control metering device. For more exact refrigerant flow,
when using units in low airflow or high outside air applications, a Thermal
Hinged Access Doors – Sheet metal hinges are available factory installed on
Expansion Valve option shall be available. This is available on High Efficiency
the Filter/Evaporator Access Door and the Compressor/Control Access Door of
Gas/Cooling units only.
all 12½ – 25 ton downflow units.
Discharge Air Sensing Kit – This option provides true discharge air sensing in
Powered or Unpowered Convenience Outlet – This option is a GFCI, 120
heating models. This sensor is a status indicator readable through Tracer® or
volt/15 amp, 2 plug, convenience outlet, either powered or unpowered. When
Tracker®. The kit is functional only with the ReliaTel™ Module.
the convenience outlet is powered, a service receptacle disconnect will be
available. The convenience outlet is powered from the line side of the Coil Guards – Hail protection quality coil guards shall be either factory or field-
disconnect or circuit breaker, and therefore will not be affected by the position installed for condenser coil protection.
of the disconnect or circuit breaker.
This option is available for all 12½– 25 ton downflow units and can only be High Efficiency Motors – This option is available with efficiency ratings from
ordered when the Through the Base Electrical with either the Disconnect Switch 86.5 up to 91.0. Not available for all models.
or Circuit Breaker option is ordered. Supply and/or Return Air Smoke Detector – With this option installed, if smoke
Reference or Comparative Enthalpy – When a factory installed Downflow is detected, all unit operation will be shut down. Reset will be manual at the unit.
Economizer is ordered, an option will be to factory install either Reference or Return Air Smoke Detectors require minimum allowable airflow when used with
Comparative Enthalpy Control. certain models. See the Installation, Operation, and Maintenance (IOM) manual
for the models affected and the minimum allowable airflow required. This option
Supply and Return Air Smoke Detector – With this option installed, if smoke is available on all 12½-25 tons downflow models.
is detected the line will shut down all operation. Reset will be manual at the unit.
Smoke detectors are photo cell. Frostat – This factory or field installed option is to be utilized as a safety device.
The Frostat opens when temperatures on the evaporator coil fall below 10°F. The
Through the Base Electrical with Circuit Breaker – This option temperature will need to rise to 50°F before closing. This option should be utilized
is a factory installed thermal magnetic, molded case, HACR Circuit Breaker in low airflow or high outside air applications.
with provisions for through the base electrical connections. The circuit breaker
will be installed in a water tight enclosure in the unit with access through a Through the Base Utilities Access – An electrical service entrance shall be
swinging door. Factory wiring will be provided from the switch to the unit high provided allowing electrical access for both control and main power connection
voltage terminal block. The circuit breaker will provide overcurrent protection, inside the curb and through the base of the unit. Option will allow for field
be sized per NEC and UL guidelines, and be agency recognized by UL/CSA. installation of liquid-tight conduit and an external field installed disconnect switch.
This option is available for all 12½ – 25 ton downflow models. Either a Circuit Novar Unit Controls – Novar rooftop unit controls will be factor installed and
Breaker or a Disconnect Switch (not both) must be ordered when ordering the tested. The Novar electronic thermostat module will interface to the unit
Through the Base Electrical option. microprocessor and will control the unit to the desired stage of cooling or heating.
The Novar electronic thermostat module will monitor the following unit
* Some FIOPs available only for certain information: fan failure status, cooling stage 1-on status, cooling stage 2 on
tonnages, unit functions, or efficiencies. status, heating on status, clogged filter status or unit shutdown status, and
discharge air temperature. The Novar electronic thermostat module will have the
ability to enable the unit mounted economizer.

Novar Return Air Sensor – This option, when used in conjunction with Novar
Before Ordering: Controls, will contain a factory provided wired zone temperature sensor located in
the return air stream.
Not all factory options are offered for single phase units.
Please contact the Clarksville, TN Support Team for latest updates of Two Inch Pleated Filters – Two inch pleated media filters shall be available on
all 12½-20 ton models.
factory installed options and ordering instructions.
Call (931) 645-6471 and ask to be connected to the Light Commercial
Product Support Team.

FIOPS-1 Effective 1/1/06


Downflow/Horizontal Packaged Cooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-2-A — Accessories
Model
Number Description Used With
Black Epoxy Coated Condenser Coil
FIYCOIL205A Black Epoxy Coated Condenser Coil T/Y/WC*150
FIYCOIL206A Black Epoxy Coated Condenser Coil T/YC*151,180,210
FIYCOIL207A Black Epoxy Coated Condenser Coil WC*180
FIYCOIL209A Black Epoxy Coated Condenser Coil T/YC*181,211,240,241,301, WC*240
FIYCOIL210A Black Epoxy Coated Condenser Coil T/YC*300
Circuit Breaker
Must be used with Through-the-Base Electrical option (downflow only).
FIYUCB3175A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB3200A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB3225A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB3250A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4015A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4020A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4025A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4030A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4035A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4040A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4045A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4050A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4060A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4070A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4080A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4090A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4100A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4110A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4125A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB4150A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB6110A Unit Mounted Circuit Breaker Consult Matrix Sheets
FIYUCB6125A Unit Mounted Circuit Breaker Consult Matrix Sheets
Convenience Outlet
Must be ordered with Through-the-Base Electrical option and either Unit Mounted Disconnect or Circuit Breaker (downflow only).
FIYCOPO201A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*3, WCD150-240*3
FIYCOPO202A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*4, WCD150-240*4
FIYCOPO205A Powered, 120V Convenience Outlet, 230V TC/YCD150-301*W, WCD150-240*W
FIYCOUP201A Unpowered, 115V Convenience Outlet TC/YCD150-301, WCD150-240
Discharge Air Sensing Kit
Used for true discharge air sensing in heating models. Functional only with ReliaTelTM Options Module (FIYABRD002B).
FIYTUBE008A Discharge Air Sensing Kit (All Voltages) TC/YCD150-301*, WCD150-240
FIYTUBE009A Discharge Air Sensing Kit (All Voltages) TC/YCH150-301*, WCH150-240
Disconnect Switch
Must be used with Through-the-Base Electrical option (downflow only). Cannot be fused.
FIYUDC3250A Unit Mounted Disconnect Switch Consult Matrix Sheets
FIYUDC4100A Unit Mounted Disconnect Switch Consult Matrix Sheets
FIYUDC4150A Unit Mounted Disconnect Switch Consult Matrix Sheets
FIYUDC6100A Unit Mounted Disconnect Switch Consult Matrix Sheets
Economizer Actuator Logic Module
FIYLGCM001A is required when ordering the following Factory Installed Options (FIOPs). Reference Enthalpy (FIYENTH007A), Comparative
Enthalpy (FIYENTH008A), Novar Controls (FIYCNTL013A, 015A,016A, 017A,018A, 019A).
FIYLGCM001A Economizer Actuator Logic Module All Voyager units with economizers and the
above mentioned FIOPs. (FIOP #s)

Effective 1/1/06 FIOPS-2


Downflow/Horizontal PackagedCooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-3-A — Accessories
Model
Number Description Used With
Electric Heat - Cooling
Must be factory installed when using with Through-the-Base Electrical option.
FIDHTRA309B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIDHTRA318B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRA327B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIDHTRA336B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRD318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRD336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRD354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRF318A Factory Installed 18 KW Electric Heat See Unit Price Sheet
FIDHTRK336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRK354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRL336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRL354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRK372A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIDHTRJ318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRJ336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRA409B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIDHTRA418B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRA427B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIDHTRA436B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRC418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRD436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRD454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRL418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRK436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRK454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRL436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRL454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRK472A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIDHTRJ418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRJ436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIDHTRCW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRCW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRKW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRKW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRLW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRKW72A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIDHTRJW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRJW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRA309B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIHHTRA318B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRA327B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIHHTRA336B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRD318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRD336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRD354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRM318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRM336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRM354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRN354A Factory Installed 54 KW Electric Heat See Unit Price Sheets

FIOPS-3 Effective 1/1/06


Downflow/Horizontal Packaged Cooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-4-A — Accessories
Model
Number Description Used With
Electric Heat - Cooling (Contd.)
FIHHTRN372A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRJ318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRJ336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRA409B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIHHTRA418B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRA427B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIHHTRA436B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRM418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRM436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRM454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRN454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN472A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRJ418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRJ436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIHHTRMW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRJW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRJW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRN318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRN418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRNW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRP336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRQ336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRP436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRQ436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRPW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRP354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRQ354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRP454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRQ454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRPW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRQW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIYHTRP105A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRP110A Factory Installed 10 KW Electric Heat See Unit Price Sheets
FIYHTRP114A Factory Installed 14 KW Electric Heat See Unit Price Sheets
FIYHTRP118A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRP306A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRP312A Factory Installed 12 KW Electric Heat See Unit Price Sheets
FIYHTRP318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRP323A Factory Installed 23 KW Electric Heat See Unit Price Sheets
FIYHTRP406A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRP412A Factory Installed 12 KW Electric Heat See Unit Price Sheets
FIYHTRP418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRP423A Factory Installed 23 KW Electric Heat See Unit Price Sheets
FIYHTRPW06A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRPW12A Factory Installed 12 KW Electric Heat See Unit Price Sheets
FIYHTRPW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRPW23A Factory Installed 23 KW Electric Heat See Unit Price Sheets

Effective 1/1/06 FIOPS-4


Downflow/Horizontal PackagedCooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-5-A — Accessories
Model
Number Description Used With
Electric Heat - Heat Pump
Must be factory installed when using with Through-the-Base Electrical option.
FIYHTRP105A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRP110A Factory Installed 10 KW Electric Heat See Unit Price Sheets
FIYHTRP114A Factory Installed 14 KW Electric Heat See Unit Price Sheets
FIYHTRP118A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRP306A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRP312A Factory Installed 12 KW Electric Heat See Unit Price Sheets
FIYHTRP318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRP323A Factory Installed 23 KW Electric Heat See Unit Price Sheets
FIYHTRP406A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRP412A Factory Installed 12 KW Electric Heat See Unit Price Sheets
FIYHTRP418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRP423A Factory Installed 23 KW Electric Heat See Unit Price Sheets
FIYHTRPW06A Factory Installed 6 KW Electric Heat See Unit Price Sheets
FIYHTRPW12A Factory Installed 12 KW Electric Heat See Unit Price Sheets
FIYHTRPW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIYHTRPW23A Factory Installed 23 KW Electric Heat See Unit Price Sheets
FIDHTRA327B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIDHTRA336B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRB309B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIDHTRB318B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRD318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRD336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRD354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRK318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRK336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRK354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRL336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRL354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRK372A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIDHTRA409B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIDHTRA418B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRA427B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIDHTRA436B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRC418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRD418A Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIDHTRD436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRD454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRK436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRK454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRL436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRL454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRK472A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIDHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIDHTRCW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIDHTRCW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRDW18A Factory installed 18 KW Electric Heat See Unit Price Sheets

FIOPS-5 Effective 1/1/06


Downflow/Horizontal PackagedCooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-6-A — Accessories
Model
Number Description Used With
Electric Heat - Heat Pump (Contd.)
FIDHTRDW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRKW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRKW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIDHTRLW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIDHTRKW72A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRA327B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIHHTRA336B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRB309B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIHHTRB318B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRD318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRD336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRD354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRM318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRM336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRM354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRN354A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN372A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRA409B Factory Installed 9 KW Electric Heat See Unit Price Sheets
FIHHTRA418B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRA427B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIHHTRA436B Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRM418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRD418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRM436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRM454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRN454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRN472A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRAW18B Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRAW27B Factory Installed 27 KW Electric Heat See Unit Price Sheets
FIHHTRMW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRMW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRCW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTREW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRNW36A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRMW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRNW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRNW72A Factory Installed 72 KW Electric Heat See Unit Price Sheets
FIHHTRN318A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRNW18A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRP336A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRP436A Factory Installed 36 KW Electric Heat See Unit Price Sheets
FIHHTRP454A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRQW54A Factory Installed 54 KW Electric Heat See Unit Price Sheets
FIHHTRP418A Factory Installed 18 KW Electric Heat See Unit Price Sheets
FIHHTRQW36A Factory Installed 18 KW Electric Heat See Unit Price Sheets

Effective 1/1/06 FIOPS-6


Downflow/Horizontal Packaged Cooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-7-A — Accessories
Model
Number Description Used With
Enthalpy Kits
FIYENTH007A Reference Enthalpy Downflow Units w/A,C or G in 10th Digit
FIYENTH008A Comparative Enthalpy Downflow Units w/A,C or G in 10th Digit
Filter & Control Access
(Downflow units only)
FIYHNGE004A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD150,180,210, WCD150-180
FIYHNGE005A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD300
FIYHNGE008A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD151
FIYHNGE009A Hinged Filter/Evap. and Comp./Control Access Door TC/YCD181,211,240,241,301, WCD240
Frostat
FIYLOAM023A Frostat TC/YCD151,181,241 with H,J,K,L in 10th digit
w/FIYABRD002B
High Efficiency Motors
Can be used on downflow or horizontal units unless specified on matrix sheets.
FIYHEMT001A 2 HP High Effic. Motor (86.5 Eff.)(208-230/460/60/3) Consult Matrix Sheets
FIYHEMT002A 2 HP High Effic. Motor (86.5 Eff.)(575/60/3) Consult Matrix Sheets
FIYHEMT003A 3 HP High Effic. Motor (89.5 Eff.)(208-230/60/3) Consult Matrix Sheets
FIYHEMT004A 3 HP High Effic. Motor (89.5 Eff.)(460/60/3) Consult Matrix Sheets
FIYHEMT005A 3 HP High Effic. Motor (89.5 Eff.)(575/60/3) Consult Matrix Sheets
FIYHEMT006A 5 HP High Effic. Motor (91.0 Eff.)(208-230/60/3) Consult Matrix Sheets
FIYHEMT007A 5 HP High Effic. Motor (91.0 Eff.)(460/60/3) Consult Matrix Sheets
FIYHEMT008A 5 HP High Effic. Motor (91.0 Eff.)(575/60/3) Consult Matrix Sheets
FIYHEMT009A 7½ HP High Effic. Motor (90.2 Eff.)(208-230/60/3) Consult Matrix Sheets
FIYHEMT010A 7½ HP High Effic. Motor (90.2 Eff.)(460/60/3) Consult Matrix Sheets
FIYHEMT011A 7½ HP High Effic. Motor (90.2 Eff.)(575/60/3) Consult Matrix Sheets
LCI
FIYLTCI003B Comm-5 LonTalk Interface TC/YC*150-301, WC*150-240
Novar Controls-2024
The Novar control option includes the following factory installed and wired devices: Novar ETM-2024 rooftop controller, fan proving switch, clogged
filter or unit shutdown switch, Cool 1,Cool 2, Heat switch and discharge air sensor (downflow only) (Novar # DTS-30, 20-170°F). NOTE: Option
cannot be ordered in conjunction with FIOPS Smoke Detector option.
FIYCNTL013A Novar Control, 208-230V T/YCD150-301*3
FIYCNTL015A Novar Control, 460 & 575V T/ YCD150-301*4,W
Novar Controls-3051
The Novar control option includes the following factory installed and wired devices: Novar 3051 rooftop controller, fan proving switch, clogged filter or
unit shutdown switch, and discharge air sensor (Novar # DTS-30, 20-170°F) (downflow only). NOTE: This option can be ordered in conjunction with
factory installed Smoke Detector option. It can also be ordered with 100% DB economizer but not with enthalpy controls.
FIYCNTL016A Novar Control, 460V, 575V TC/ YCD181,211,240,241,300,301*4,W
FIYCNTL017A Novar Control, 208-230V TC/ YCD150,151,180,210*3
FIYCNTL018A Novar Control, 460V, 575V TC/YCD150,151,180,210*4,W
FIYCNTL019A Novar Control, 208-230V TC/YCD181,211,240,241,300,301*3
Novar Return Air Sensor
This option consists of the Novar return air sensor (Novar # WTS-10) that is wired and shipped in the return air section of the unit. The sensor
ships with approximately 15' of extra wire for dropping down the return air duct (downflow only).
FIYNRAS001A Return Air Sensor FIYCNTL013A and FIYCNTL015A
Novar Zone Sensor
This option consists of a Novar Zone Sensor (Novar #WTS-SOS) used with Novar 3051 Controls.
FIYNZSR001A Novar Zone Sensor for Novar 3051 FIYCNTL016A
ReliaTelTM Options Module
FIYABRD002B is required when ordering the following accessories: Clogged Filter Switch (FIYDFPS005A/BAYDFPS005A), Fan Fail Switch (FIYDFPS006A/
BAYDFPS006A), Discharge Air Sensing Kit (FIYTUBE008A,FIYTUBE009A, BAYTUBE008A, BAYTUBE009A), Frostat (FIYLOAM023A, BAYLOAM023A),
Ventilation Override (must order BAYVNOR002B), Smoke Detector (FIYSMDT).
FIYABRD002B ReliaTelTM Options Module All Voyager Units

FIOPS-7 Effective 1/1/06


Downflow/Horizontal PackagedCooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-8-A — Accessories
Model
Number Description Used With
Smoke Detector (Return Air) for downflow units with economizer123
Option cannot be ordered in conjunction with field installed economizer.
FIYSMDT221A Return Air Smoke Detector TC/YCD150,151,180,210, WCD150,180
FIYSMDT223A Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240
Smoke Detector (Return Air) for downflow units without economizer123
FIYSMDT222A Return Air Smoke Detector TC/YCD150,151,180,210, WCD150,180
FIYSMDT224A Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240
Smoke Detector (Supply Air) for downflow units 23
FIYSMDT225A Supply Air Smoke Detector TC/ YCD150,151,180,210, WCD150B-180
FIYSMDT228A Supply Air Smoke Detector TC/ YCD181,211,240,241,300,301, WCD240
Smoke Detectors (Supply and Return Air) for downflow units with economizer123
Option cannot be ordered in conjunction with field installed economizer.
FIYSMDT226A Supply and Return Air Smoke Detector TC/ YCD150,151,180,210, WCD150,180
FIYSMDT229A Supply and Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240
Smoke Detectors (Supply and Return Air ) for downflow units without economizer123
FIYSMDT227A Supply and Return Air Smoke Detector TC/ YCD150,151,180,210, WCD150,180B
FIYSMDT230A Supply and Return Air Smoke Detector TC/YCD181,211,240,241,300,301, WCD240B
1 The return air smoke detector may not fit up or work properly on the Voyager units when used in conjunction with 3rd party accessories (such as bolt on
heat wheels, economizers, and power exhaust). Do not order the return air smoke detectors when using this type of accessory.
2 Smoke Detectors available for downflow units only.
3 Functional only with ReliaTel ™ Options Module (FIYABR002B).
Stainless Steel Heat Exchanger
FIYSSHX001A 150 MBH Stainless Steel Heat Exchanger YC*150,151 Low Heat
FIYSSHX002A 250 MBH Stainless Steel Heat Exchanger YC*150,151 High Heat
YC*155,175,180,181,200,210,211,240,241,250,300 and
301 Low Heat
FIYSSHX003A 350 MBH Stainless Steel Heat Exchanger YC*155,175,180,181,210,211 High Heat
FIYSSHX004A 400 MBH Stainless Steel Heat Exchanger YC*200,240,241,250,300,301 High Heat
Switches1
FIYDFPS005A Clogged Filter Switch All Voyager Units
FIYDFPS006A Fan Failure Switch All Voyager Units
1 Functional only with ReliaTel ™ Options Module (FIYABR002B).
TCI
FIYICSI004B Trane Communication Interface All Units w/B or C in 10th Digit and
- when combination of oversize TXV Units w/H, J, K or L in 10th Digit
motor and TCI is required.

Effective 1/1/06 FIOPS-8


Downflow/Horizontal Packaged Cooling,
Packaged Gas/Electric/Packaged Heat
Pump Factory Installed Options (FIOPS)
Table FIOPS-9-A — Accessories
Model
Number Description Used With
Through the Base Electrical
Must be used with Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker (downflow only). When adding heat, must order Trane Electric Heat. If no factory installed Unit
Mounted disconnect Switch or Unit Mounted Circuit Breaker is required, order the Through the Base Utility Access Option (FIYTBUA****)
FIYTBUE206A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE207A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE208A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE209A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE210A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE211A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE212A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE213A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE214A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE215A Through-the-Base Electrical Option Consult Matrix Sheets
FIYTBUE216A Through-the-Base Electrical Option Consult Matrix Sheets
Through The Base Gas Piping
FIYTBUG202A1 Through-the-Base Gas Piping YCD150,151 Low & High Heat
YCD180-301 Low Heat
FIYTBUG203A1 Through-the-Base Gas Piping YCD180-301 High Heat
FIYTBUG205A2 Through-the-Base Gas Piping YCD150,151 Low & High Heat
YCD180-301 Low Heat
FIYTBUG206A2 Through-the-Base Gas Piping YCD180-301 High Heat
1 Must order when ordering through-the-base electrical or through-the-base access option (downflow only).
2 Order when not ordering through-the-base electrical or through-the-base access option (downflow only).
Through the Base Utilities Access
Order this accessory when no factory installed Unit Mounted Disconnect Switch or Unit Mounted Circuit Breaker is required. If factory installed Unit Mounted
Disconnect or Unit Mounted Circuit Breaker is required, order the Through the Base Electrical Option (FIYTBUE****) from the FIOP Matrix page.
FIYTBUA204A Through the Base Utilities Access YCD150,151,180,210
FIYTBUA205A Through the Base Utilities Access TCD150,151,180,210, WCD150,180
FIYTBUA206A Through the Base Utilities Access YCD181,211,240,241,300,301
FIYTBUA207A Through the Base Utilities Access TCD181,211,240,241,300,301, WCD240,300
Tool-less Condenser Hail Guard
FIYGARD001B Tool-less Condenser Hail Guard TC/YC*150, WC*150
FIYGARD002B Tool-less Condenser Hail Guard TC/YC*151,180,210, WC*180
FIYGARD003A Tool-less Condenser Hail Guard TC/YC*181,211,240,241,301,WC*240
FIYGARD005A Tool-less Condenser Hail Guard TC/YC*300
2" Pleated Filters
FIYPLTD001A 2" Pleated Filters TC/YC*150,151,180,210, WC*150,180
FIYPLTD002A 2" Pleated Filters TC/YCD181,211,240,241,300,301, WCD240
FIYPLTD003A 2" Pleated Filters TC/YCH181,211,240,241,300,301, WCH240

FIOPS-9 Effective 1/1/06


Downflow Packaged Cooling, & Gas Electric
Factory Installed Options (FIOPS)
Matrix Page
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker

Effective 1/1/06
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
CO* (*=0) Cooling & CO* & CO* &
GE* (* = L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW
T/YFD150D3*0B 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 6125 3200 N/A
T/YFD150D3*BB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 4150 3200 N/A
T/YFD150D4*0B 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4090 N/A
T/YFD150D4*BB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/A
T/YFD150DW*0B 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/A
T/YFD150DW*BB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4060 4080 N/A
T/YFD151C3*0B 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 6125 3200 N/A
T/YFD151C3*BB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4090 4090 N/A 4150 3200 N/A
T/YFD151C4*0B 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4090 N/A
T/YFD151C4*BB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/A
T/YFD151CW*0B 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/A
T/YFD151CW*BB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4060 4080 N/A
T/YFD151C3*HB 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4070 4070 N/A 6125 3200 N/A
T/YFD151C3*JB 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4080 4080 N/A 4150 3200 N/A
T/YFD151C4*HB 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4035 4035 N/A 4070 4090 N/A
T/YFD151C4*JB 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4070 4100 N/A
T/YFD151CW*HB 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4050 4070 N/A
T/YFD151CW*JB 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4030 4030 N/A 4060 4080 N/A
T/YFD180B3*0H 003 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/A
T/YFD180B3*BH 006 207/206 208 N/A 209 210 N/A 6100 6100 N/A 4150 3250 N/A 4100 4100 N/A 4150 3200 N/A

FIOPS-10
T/YFD180B4*0H 004 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4090 N/A
T/YFD180B4*BH 007 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/A
T/YFD180BW*0H 005 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/A
T/YFD180BW*BH 008 207/206 208 N/A 208 208 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/A
T/YFD181C3*0C 003 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/A
T/YFD181C3*BC 006 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4100 4100 N/A 4150 3200 N/A
T/YFD181C4*0C 004 213/211 214 214 214 214 N/A 6100 6100 6100 6100 6100 N/A 4050 4050 4050 4070 4090 N/A
T/YFD181C4*BC 007 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/A
T/YFD181CW*0C 005 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/A
T/YFD181CW*BC 008 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/A
T/YFD181C3*HC 003 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4100 N/A 6125 3200 N/A
T/YFD181C3*JC 006 213/212 214 N/A 215 216 N/A 6100 6100 N/A 4150 3250 N/A 4090 4090 N/A 4150 3200 N/A
T/YFD181C4*HC 004 213/211 214 214 214 214 N/A 6100 6100 6100 6100 6100 N/A 4050 4050 4050 4070 4090 N/A
T/YFD181C4*JC 007 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4050 4050 N/A 4070 4100 N/A
T/YFD181CW*HC 005 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4050 4070 N/A
T/YFD181CW*JC 008 213/211 214 N/A 214 214 N/A 6100 6100 N/A 6100 6100 N/A 4040 4040 N/A 4060 4080 N/A
FACTORY INSTALLED OPTIONS (FIOPS)
(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. T/YCD). ALL FACTORY INSTALLED
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat.
OPTIONS ARE BUILT-TO-ORDER.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for CHECK ORDER SERVICES FOR
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th ESTIMATED PRODUCTION CYCLE.
digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th
digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with model number with "J" in 10th digit for FIOP selections.
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
CO* = Cooling Only GE* = Gas Electric
Downflow Packaged Cooling, & Gas Electric
Factory Installed Options (FIOPS)
Matrix Page (Contd.)
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
CO* (*=0) Cooling & CO* &
GE* = (*= L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW CO*/GE* 18KW 27KW 36KW 54KW 72KW
T/YFD210C3*0E 006 207/206 N/A N/A 209 210 N/A 6100 N/A N/A 4150 3250 N/A 4100/4100 N/A N/A 4150 3200 N/A
T/YFD210C3*BE 009 207/206 N/A N/A 209 210 N/A 4150 N/A N/A 4150 3250 N/A 6125/4125 N/A N/A 4150 3200 N/A
T/YFD210C4*0E 007 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4050/4050 N/A N/A 4070 4100 N/A
T/YFD210C4*BE 010 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4060/4060 N/A N/A 4070 4100 N/A
T/YFD210CW*0E 008 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4045/4045 N/A N/A 4060 4080 N/A
T/YFD210CW*BE 011 207/206 N/A N/A 208 208 N/A 6100 N/A N/A 6100 6100 N/A 4045/4045 N/A N/A 4060 4080 N/A
T/YFD211C3*0C 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6110/4110 N/A N/A 4150 3200 3250
T/YFD211C3*BC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD211C4*0C 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125
T/YFD211C4*BC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
T/YFD211CW*0C 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4045/4045 N/A N/A 4060 4080 4100
T/YFD211CW*BC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD240B3*0J 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD240B3*BJ 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD240B4*0J 007 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
T/YFD240B4*BJ 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125

FIOPS-11
T/YFD240BW*0J 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4045/4045 N/A N/A 4060 4080 4100
T/YFD240BW*BJ 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD241C3*0C 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C3*BC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C4*0C 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125
T/YFD241C4*BC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4060/4060 N/A N/A 4070 4100 6125
T/YFD241CW*0C 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
TFD241CW*BC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD241C3*HC 006 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C3*JC 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 6125/4125 N/A N/A 4150 3200 3250
T/YFD241C4*HC 007 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4060/4060 N/A 4060 4070 4100 6125
T/YFD241C4*JC 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4070/4070 N/A N/A 4070 4100 6125
T/YFD241CW*HC 008 213/211 N/A N/A 214 214 214 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100
T/YFD241CW*JC 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050/4050 N/A N/A 4060 4080 4100

FACTORY INSTALLED OPTIONS (FIOPS)


(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. T/YCD).
ALL FACTORY INSTALLED
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat. OPTIONS ARE BUILT-TO-ORDER.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for CHECK ORDER SERVICES FOR
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th ESTIMATED PRODUCTION CYCLE.
digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th
digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with
model number with "J" in 10th digit for FIOP selections.
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
CO* = Cooling Only GE* = Gas Electric

Effective 1/1/06
Downflow Packaged Cooling, & Gas Electric
Factory Installed Options (FIOPS)

Effective 1/1/06
Matrix Page (Contd.)
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1)(4) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
CO* (* = 0) Cooling & CO* & CO* &
GE* = (L or H Heat) Gas Electric CO*/GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW GE* 18KW 27KW 36KW 54KW 72KW
T/YFD300B3*0H 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 4150 N/A N/A 4150 3200 3250
T/YFD300B4*0H 010 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 4150 4070 N/A N/A 4070 4100 6125
T/YFD300BW*0H 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4050 N/A N/A 4060 4080 4100
T/YFD301C3*0C 009 213/212 N/A N/A 215 216 216 4150 N/A N/A 4150 3250 3250 4150 N/A N/A 4150 3200 3250
T/YFD301C4*0C 010 213/211 N/A 214 214 214 215 6100 N/A 6100 6100 6100 4150 4070 N/A 4070 4070 4100 6125
T/YFD301CW*0C 011 213/211 N/A N/A 214 214 215 6100 N/A N/A 6100 6100 6100 4060 N/A N/A 4060 4080 4100

FACTORY INSTALLED OPTIONS (FIOPS)


(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. T/YCD).
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th
digit for FIOP selections. When ordering thermal expansion valve ("H" in 10th digit) with economizer ("L" in 10th digit) use line with model number with "H" in the 10th
digit for FIOP selections; when ordering thermal expansion valve with oversized motor ("J" in 10th digit) or oversized motor & economizer ("K" in 10th digit) uses line with
model number with "J" in 10th digit for FIOP selections.

FIOPS-12
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
CO* = Cooling Only
GE* = Gas Electric

ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER.


CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.
Downflow Packaged Heat Pump
Factory Installed Options (FIOPS)
Matrix Page
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
without without without
aux. heat aux. heat aux. heat
CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW
WFD150B300G 003 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4080 6125 3175 3250 N/A
WFD150B30BG 006 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4080 4150 3200 3250 N/A

FIOPS-13
WFD150B400G 004 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4040 4060 4090 6125 N/A
WFD150B40BG 007 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4040 4070 4090 6125 N/A
WFD150BW00G 005 207 208 208 208 N/A 6100 6100 6100 6100 N/A 4030 4050 4070 4090 N/A
WFD150BW0BG 008 207 208 208 208 N/A 6100 6100 6100 6100 N/A 4035 4050 4080 4100 N/A
FACTORY INSTALLED OPTIONS (FIOPS)
(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. WCD).
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th
digit for FIOP selections.
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
* Cooling Only

Effective 1/1/06
Downflow Packaged Heat Pump

Effective 1/1/06
Factory Installed Options (FIOPS)
Matrix Page (Contd.)
High Efficiency Through-the-Base Electrical Unit Mounted Disconnect Unit Mounted Circuit Breaker
Model Motors FIYTBUE___A (3) FIYUDC____A (2) FIYUCB____A (2)
Number (1) FIYHEMT___A (5) (Downflow Only) (Downflow Only) (Downflow Only)
without without without
aux. heat aux. heat aux. heat
CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW CO* 18KW 36KW 54KW 72KW
WFD180B300G 003 207 209 210 210 N/A 6100 4150 3250 3250 N/A 4090 4150 3200 3250 N/A
WFD180B30BG 006 207 209 210 NA N/A 6100 4150 3250 3250 N/A 4100 4150 3200 3250 N/A
WFD180B400G 004 207 208 208 209 N/A 6100 6100 6100 4150 N/A 4045 4070 4100 6125 N/A
WFD180B40BG 007 207 208 209 209 N/A 6100 6100 6100 4150 N/A 4050 4070 4100 6125 N/A
WFD180BW00G 005 207 208 208 209 N/A 6100 6100 6100 6100 N/A 4035 4060 4080 4100 N/A
WFD180BW0BG 008 207 208 208 209 N/A 6100 6100 6100 6100 N/A 4040 4060 4080 4100 N/A
WFD240B300G 006 213 N/A 216 216 N/A 4150 N/A 3250 NA N/A 6125 N/A 3225 NA N/A
WFD240B30BG 009 213 N/A 216 NA N/A 4150 N/A 3250 NA N/A 6125 N/A 3225 NA N/A
WFD240B400G 007 213 N/A 215 215 N/A 6100 N/A 4150 4150 N/A 4060 N/A 6110 4150 N/A

FIOPS-14
WFD240B40BG 010 213 N/A 215 215 N/A 6100 N/A 4150 4150 N/A 4060 N/A 6110 4150 N/A
WFD240BW00G 008 213 N/A 214 215 215 6100 N/A 6100 4150 4150 4045 N/A 4090 6110 6125
WFD240BW0BG 011 213 N/A 214 215 215 6100 N/A 6100 4150 4150 4050 N/A 4090 6110 4150

FACTORY INSTALLED OPTIONS (FIOPS)


(1) Unit model # changes to "F" in 2nd digit, indicating desire for factory installed options (unit nameplate will still reflect standard model #, i.e. WCD).
(2) Unit mounted disconnect and circuit breakers are mutually exclusive of each other.
(3) Through-the-base electrical option must be ordered with either unit mounted disconnect or circuit breaker. When adding heat, must order Trane Electric Heat.
(4) When ordering economizer ("A" in 10th digit), TCI ("F" in 10th digit), or economizer and TCI ("G" in 10th digit) use line with model number with "0" in 10th digit for
FIOP selections; when ordering oversized motor ("B" in 10th digit) or oversized motor & economizer ("C" in 10th digit) uses line with model number with "B" in 10th
digit for FIOP selections.
(5) High efficiency motors can be factory installed on downflow and horizontal units unless noted. When ordering horizontal units with high efficiency motors,
unit model # changes to "H" in 3rd digit.
* Cooling Only

ALL FACTORY INSTALLED OPTIONS ARE BUILT-TO-ORDER.


CHECK ORDER SERVICES FOR ESTIMATED PRODUCTION CYCLE.
Comfort Control
Definitions

Calibration Manual or Mechanical


The relationship of the dial setting and Differential
the cut-in temperature of the The difference (Degrees F) between
thermostat. cut-in and cut-out temperature with no
electrical load connected to the
thermostat.
ComfortLinkTM
An open architecture communications
bridge for reliably interfacing to Operating Differential
automation and energy management The difference (Degrees F) in
systems. cut-in and cut-out temperature when
the thermostat is actually operating
equipment. Operating differential is
Cut-in Point less than mechanical differential.
The temperature at which the
thermostat calls for system operation.
Range
Minimum to maximum temperature
Cut-out Point scale shown on dial.
The temperature at which the
thermostat stops calling for
heating or cooling. Sensor
A device that measures and
communicates temperature of the
Cycle Rate conditioned space in which it is
The number of times per hour that the located to a system controller.
heating equipment is cycled on at
half load conditions.
Set Point
The temperature at which the
Droop thermostat indicator is set.
An indoor temperature control
condition where the room remains
below the thermostat setting. This Two Piece Thermostat
control occurs in mild cooling System consisting of a sensor
conditions and is caused by the mounted in the controlled space
cooling anticipator resistor which communicating to a controller which
provides a false heat source: for establishes the systems operation.
the thermostat to maintain relative
humidity control.
Power Stealing 4 Wire
Resistor Terminal in Box. 4-wire
Heat Anticipator system to supply power with heating
(Sometimes called a Preheat mode; steals power from "y" in
Resistor.) cooling.

A bias heater that shuts off the


thermostat before the room
reaches the thermostat setting.

CCZO-1 Effective 1/1/06


Programmable 7 Day
Comfort Controls

TCONT800A Application:
• Interactive Touchscreen • 1 Heat/1 Cool (Gas, Oil or Electric)
• Effortless Programming • 1 Heat/0 Cool (Gas, Oil or Electric)
• Large, Backlit Display • 0 Heat/1 Cool
• Streamlined Design • ZZSENSAL0800AA - Remote Indoor
• Armchair Programming Temperature Sensor
• Real Time Clock Dimensions:
• Visual Reminder Cues • 6.02” w x 4.62” h
• BAYCOVR600A - Wall cover plate • Finish: Bright White
• Energy Star

TCONT802A Application:
• Interactive Touchscreen • Up to 3 Heat/2 Cool
• Effortless Programming (Gas, Oil or Electric)/HP
• Large, Backlit Display • ZZSENSAL0800AA - Remote Indoor
• Streamlined Design Temperature Sensor
• Armchair Programming Dimensions:
• Real Time Clock • 6.02” w x 4.62” h
• Visual Reminder Cues • Finish: Bright White
• BAYCOVR600A - Wall cover plate
• Energy Star

TCONT803A Application:
• Built-in Humidity Sensor • Up to 3 Heat/2 Cool
• Dehumidification Control (Gas, Oil or Electric)/HP
• Interactive Touchscreen • ZZSENSAL0800AA - Remote Indoor
• Effortless Programming Temperature Sensor
• Large, Backlit Display Dimensions:
• Streamlined Design • 6.02” w x 4.62” h
• Armchair Programming • Finish: Bright White
• Real Time Clock
• Visual Reminder Cues
• BAYCOVR600A - Wall cover plate
• Energy Star

BAYCOVR600A
Application: • Finish: Bright White
• Use with TCONT800A Series Comfort
Controls

Effective 1/1/06 CCZO-2


Programmable 7 Day
Comfort Controls

ed
• Outdoor Temperature Display (Optional • Minimum Compressor Run Time
Accessory – TAYSENS100A) (Factory Set to 10 Minutes, Field
s
a t • Bright Backlight Display Adjustable)

h • 4-wire hook up-register is supplied for • Vacation/Leave Program; Will Hold

P u
PHASED
systems with electric heat Vacation/Leave Temperature for up to
• Filter Clean/Replacement Key (Field 256 Days
O Adjustable)
• No Batteries Required; Super Cap
• Field Temperature Re-Calibration Offset
(Field Adjustable); Allows Installer to Set
Continues Clock for an Average of Thermostat to Customer’s Wall-Mounted
30 Minutes Thermostat Setting
TAYSTAT300C • Programming and Other Functions • Fan-On Heat with Terminal (Heat/Cool
Stored in Permanent “E-PROM” Memory Models, Field Adjustable); i.e. Fan “G”
XT300C

OUT
• Conventional or Adaptive Intelligent is Activated with “W” (Electric Heat
• Single Stage Heating/Cooling Recovery (Field Selectable) Installations)
• 7 Day, 24 Hour or Constant • Daylight Savings Time Key • “Comfort "R"™” Enhanced Cooling for
Temperature Programming • Gas only models do not need resistor PSC Motors, Field Activated (This is
• 4 Temperature Set Points Per Day • Programmable Fan – Fan can be Only a Portion of Comfort "R"™ that is
• Power Stealing 4-wire Programmed in the “ON” or “AUTO” Achieved with Variable Speed Equip-
• Manual or Auto Changeover (Field Mode for Each Period ment)
Selectable) • Finish: Bright White

ed
• Bright Backlight Display • Vacation/Leave Program; Will Hold
• Filter Clean/Replacement Key (Field Ad- Vacation/Leave Temperature for up to
s
a t
justable) 256 Days

h
PHASED
• No Batteries Required; Super Cap • Field Temperature Re-Calibration Offset

P u Continues Clock for an Average of


30 Minutes
(Field Adjustable); Allows Installer to Set
Thermostat to Customer’s Wall -
O • Programming and Other Functions
Stored in Permanent “E-PROM” Memory
Mounted Thermostat Setting
• Fan-On Heat with Terminal (Heat/Cool
• Must be set for 2 Heat/2 Cool by installer Models, Field Adjustable); i.e. Fan “G”
TAYSTAT302C • Factory shipped 2 Heat/ 1 Cool is Activated with “W” (Electric Heat
XT302C • Conventional or Adaptive Intelligent Installations)

OUT
• 2 Heat/2 Cool Recovery (Field Selectable) • “Comfort "R"™” Enhanced Cooling for
• 7 Day, 24 Hour or Constant • Daylight Savings Time Key PSC Motors, Field Activated (This is
Temperature Programming • Programmable Fan – Fan can be Only a Portion of Comfort "R"™ that is
• 4 Temperature Set Points Per Day Programmed in the “ON” or “AUTO” Achieved with Variable Speed Equip-
• Manual or Auto Changeover (Field Mode for Each Period ment)
Selectable) • Minimum Compressor Run Time • Finish: Bright White
• Outdoor Temperature Display (Optional (Factory Set to 10 Minutes, Field
Accessory – TAYSENS100A) Adjustable)

ed
as t
PHASED
• Filter Clean/Replacement Key (Field • Minimum Compressor Run Time (Factory
Adjustable) Set to 10 Minutes, Field Adjustable)
h
P u • No Batteries Required; Super Cap
Continues Clock for an Average of
• Vacation/Leave Program; Will Hold
Vacation/Leave Temperature for up to
O 30 Minutes
• Field Select 1 or 2 Stage
256 Days
• Field Temperature Re-Calibration Offset
TAYSTAT500C • Programming and Other Functions (Field Adjustable); Allows Installer to Set
XT500C Stored in Permanent “E-PROM” Memory Thermostat to Customer’s Wall-Mounted

OUT
• Conventional or Adaptive Intelligent Thermostat Setting
• 2 Heat/1 Cool
• 3 Heat/2 Cool Heat Pumps Recovery (Field Selectable) • Fan-On Heat with Terminal (Heat/Cool
• 7 Day, 24 Hour or Constant • Factory shipped 2 Heat/1 Cool Models, Field Adjustable); i.e. Fan “G” is
Temperature Programming Activated with “W” (Electric Heat
• If needed, Installation setup allows Installations)
• 4 Temperature Set Points Per Day control to be used in 3 Heat/1 Cool
• Manual or Auto Changeover (FieldSe- • “Comfort "R"™” Enhanced Cooling for
lectable) • Daylight Savings Time Key PSC Motors, Field Activated (This is Only
• Outdoor Temperature Display • Programmable Fan – Fan can be a Portion of Comfort "R"™ that is
(Optional Accessory – TAYSENS100A) Programmed in the “ON” or “AUTO” Achieved with Variable Speed Equipment)
• Bright Backlight Display Mode for Each Period • Finish: Bright White

CCZO-3 Effective 1/1/06


Programmable 5/2 Day
Comfort Controls

• 1 Heat/1 Cool • Plain language (no symbols)


• 5/2 or 5/1/1 Programming • Easy battery access
• Simple to Install and Use • Easy to understand soft key controls
• Front Wired (Wires attach to wall • Energy Star
plates) • BAYCOVR700A - Wall cover plate
• Standard Wiring Terminal Block Dimensions:
TCONT600A • Easy to follow Sequential Program- • 5.81” w x 3.56” h
ming • Finish: Bright White
• Inside and set temperatures displayed
simultaneously

• 2 Heat/2 Cool • Plain language (no symbols)


• 5/2 or 5/1/1 Programming • Easy battery access
• Simple to Install and Use • Easy to understand soft key controls
• Front Wired (Wires attach to wall • BAYCOVR700A - Wall cover plate
plates) • Energy Star
TCONT602A • Standard Wiring Terminal Block Dimensions:
• Easy to follow Sequential • 5.81” w x 3.56” h
Programming • Finish: Bright White
• Inside and set temperatures displayed
simultaneously

Application: • Finish: Bright White


• Use with TCONT600A Series Comfort
Controls

BAYCOVR700A
• 1 Heat (Gas/Electric)/1 Cool • Programming Stored In Permanent

d
Phase
• Heat/Off/Cool System Switch “E-PROM” Memory
• Power Stealing 4 Wire • No Batteries

Out
TAYSTAT340




PHASED OUT
5/2 Programmable
Auto/On Fan Switch
Manual Changeover
Super Cap Continues Clock for an
Average of 30 Minutes
• Fuel Selection Switch (Gas/Electric)
• Adjustable Heating Cycle Rate
• Finish: Bright White

d
Phase
• 2 Heat (Gas)/1 Cool • Programming Stored In Permanent
• Heat/Off/Cool System Switch “E-PROM” Memory
• 5/2 Programmable • No Batteries

Out
TAYSTAT350



PHASED OUT
Auto/On Fan Switch
Manual Changeover
Super Cap Continues Clock for an
Average of 30 Minutes
• Adjustable Heating Cycle Rate
• 6-wire connection
• Finish: Bright White

d
Phase
• 2 Heat/1 Cool • Programming Stored In Permanent
• Heat/Off/Cool/Emergency Heat “E-PROM” Memory
System Switch • No Batteries

Out
Heat Pump
TAYSTAT540
PHASED OUT
• 5/2 Programmable
• Auto/On Fan Switch
• Manual Changeover
• Super Cap Continues Clock for an
• Adjustable Heating Cycle Rate
• Finish: Bright White

Average of 30 Minutes

Effective 1/1/06 CCZO-4


Non-Programmable
Comfort Controls

TCONT401A • 1 Stage Cool, 1 Stage Heat


• Auto Changeover (Gas, Electric or Oil*)
• Backlit Display & Keys • 1 Stage Cool, 0 Stage Heat
• Comfort Information Compartment • 0 Stage Cool, 2 Stage Heat
• Energy Savings Mode (Gas, Electric or Oil*)
• Filter Reminder • 0 Stage Cool, 1 Stage Heat
• Outdoor Temperature Sensor (Gas, Electric or Oil*)
• Keypad Lock Dimensions:
Application (3-9 Wire Hookup -2 6.75" w x 4.52" h
for Outdoor Sensor) Heat Pump* • Finish: Bright White
or A/C * Requires external relay for oil furnace
• 1 Stage Heat Pump**, 1 Stage Aux applications.
Heat ** External TAYPLUS103A required for
• 1 Stage Heat Pump**, 0 Stage Aux dual fuel applications.
Heat BAYSEN01ATEMPAA required for
• 1 Stage Cool, 2 Stage Heat outdoor temperature sensing and
(Gas, Electric or Oil*) display

TCONT402A Dimensions:
• Auto Changeover 6.75" w x 4.52" h
• Backlit Display & Keys • Finish: Bright White
• Comfort Information Compartment * Requires external relay for oil furnace
• Energy Savings Mode applications.
• Filter Reminder * Installation is required for outdoor
• BAYSEN01ATEMPAA-Outdoor temperature sensing and display
Temperature Sensor included* * BAYSEN01ATEMPAA required for
• Keypad Lock outdoor temperature sensing and
Application (3-9 Wire Hookup -2 display
for Outdoor Sensor) Heat Pump*
or A/C
• 3 Heat/2 Cool
• No external Dual Fuel Kit Required
• ZZSENSAL0400AA - Remote Indoor
Temperature Sensor

TCONT200A Dimensions:
• Auto Changeover • 4.25" (W) x 5.33" (H)
• Back Lit Display & Keys Application (4 wire hookup - power
• Comfort Information Compartment stealing)*
• Energy Savings Mode • 1 Heat/1 Cool (Gas, Oil or electric)
• Filter Reminder • 1 Heat/0 Cool (Gas, Oil or electric)
• Key Pad Lock • 0 Heat/1 Cool
• Finish: Bright White

CCZO-5 Effective 1/1/06


Non-Programmable
Comfort Controls

TAYSTAT380 • No Batteries

se d • 2 Heat (Gas)/1 Cool • Permanent Temperature Setting

Pha
Out




PHASED OUT
Heat/Off/Cool System Switch
Auto/On Fan Switch
Manual Changeover
Digital Display
Retention
• Adjustable Heating Cycle Rate
• Finish: Bright White

Heat Pump • Digital Display

d TAYSTAT570 • No Batteries

Phase
PHASED OUT
• 2 Heat /1 Cool • Permanent Temperature Setting
• Heat/Off/Cool/Emergency Heat Retention

Out System Switch • Finish: Bright White


• Auto/On Fan Switch
• Manual Changeover

Heat Pump • Auto/On Fan Switch Keyboard

d TAYSTAT575 • No Batteries

Phase
Heat

PHASED OUT
• 3 Heat /2 Cool (Field Selectable) • Manual or Auto Changeover
• Factory Ships 2 Heat/1 Cool • Permanent Temperature Setting

Out • Lighted Digital Display Retention


• Emergency Heat/Off/Cool Auto System • Finish: Bright White
Keyboard

TAYSTAT375 • Heat/Off/Cool/Auto System Keyboard


d
Phase
• 2 Heat (Gas/Electric) /2 Cool (Field • Auto/On Fan Switch Keyboard

PHASED OUT
Heat

Selectable) • Manual or Auto Changeover


• Factory Ships 2 Heat/1 Cool • No Batteries

Out • Lighted Digital Display


• Permanent Temperature Setting
• Finish: Bright White

Retention

TAYSTAT370 • Digital Display


d
Phase
• 1 Heat (Gas)/1 Cool • No Batteries

Out




PHASED OUT
Power Stealing 4 Wire
Heat/Off/Cool System Switch
Auto/On Fan Switch
Manual Changeover
• Permanent Temperature Setting
Retention
• Adjustable Heating Cycle Rate
• Finish: Bright White

TAYSTAT371 • Manual Changeover


• 1 Heat (Electric)/1 Cool • Digital Display
d
Phase PHASED OUT
• Power Stealing 4 Wire • No Batteries
• Resistor must be installed (shipped • Permanent Temperature Setting
Retention

Out
with control)
• Heat/Off/Cool System Switch • Finish: Bright White
• Auto/On Fan Switch

Effective 1/1/06 CCZO-6


Remote Sensors

BAYSEN02ATEMPAA
• Outdoor Temperature Sensor for Use
with TCONT800, 802, 803
• Accuracy +/– 1°F from –40 to 120°F

ed TAYSENS100A • Finish: Bright White

as PHASED OUT
• Outdoor Temperature Sensor for Use

Ph ut
with TAYSTAT300C, 302C, 500C, 575
and 375
• Accuracy +/– 1°F from –40 to 120°F
O
BAYSEN01ATEMPAA
• Outdoor Temperature Sensor for Use
with TCONT401A & 402A
• Accuracy
+/- 15°F over 32°F to 100°F
• Display Range
-40°F to 140°F

ZZSENSAL0400AA
• Indoor Sensor for Use with Dimensions in in. (mm):
TCONT402 Comfort Controls • 1.54 (39) wide x 1.93 (49) high x .625
• Operating Ambient Temperature (1.6) deep
Range: 20° to 120°F (-6.7° to 48.9°C) • Storage Temperature: -40° to 140°F
• Display Range: 20° to 120°F (-40° to 60°C)
(-6.7° to 48.9°C) • Finish: White
• Sensor Accuracy: +/-.5°F at 75°F
• Operating Relative Humidity: 5% to
90% non-condensing

ZZSENSAL0800AA
• Indoor Temperature Sensor for Use Dimensions in in. (mm):
with TCONT800, 802, 803 • 1.50 (38) wide x 2.28 (58) high x .70
• Operating Ambient Temperature (18) deep
Range: 45 to 88°F (7.2 to 32°C) • Finish: White
• Display Range: 0 to 99°F (-18 to 37°C)
• Sensor Accuracy: +/-1.5°F at 70°F
(+/-.84 at 21°C)
• Operating Relative Humidity: 5% to
95% non-condensing

CCZO-7 Effective 1/1/06


Humidity Control

• Heating Cycle Humidity Control


The humidity control provides automatic
low voltage control of humidifiers in
central heating and cooling applications.
It has an spst, snap-acting, dust-proof
Humidity Control
switch that opens when humidity rises
above the control setting. It is designed
for wall or surface duct mounting.

• Cooling Cycle Humidity*


When activated, the humidity control
lowers the furnace/air handler blower
speed, reducing air velocity over the
furnace/air handler coil and removing a
greater amount of moisture from the air.
BAYSTAT253A
• Bright White Finish

* For use w/variable speed indoor products


"ONLY"

Relay Hook-Up

• BAY24X042 relay for fan operation


when using electric heat.
• This sample hook-up diagram
illustrates Field Connections for
cooling only units, electric heat and
automatic change over control.
• On a call for heat, the relay provides
for instant fan-on. Without the relay,
BAY24X042 you will get no airflow or heat! Relay
Relay is not needed with Fossel Fuel on
Heat Pump applications.

Effective 1/1/06 CCZO-8


Indoor Fan Delay Relay Kit

BAY24X045
• For application to furnaces and air
handlers with cooling coils equipped
with capillary tube or 15% bleed
expansion valve components.
• This kit allows the indoor fan to
continue to run a short time after the
outdoor unit shuts off for increased
cooling efficiency.
• The kit contains: 1 solid state time
delay relay with four (4) color coded
wires, 1 wiring diagram, 1 notice label,
1 mounting screw.

Outdoor Thermostat Kit


TAYSTAT250B
• The outdoor thermostat (ODT) is
designed to turn "ON" the supple-
mentary heater at a pre-selected
outdoor temperature.
• The number and setting of the ODT
is dependent on the heat loss of the
structure and capacity of the heating
system installed.
• This model ODT gives a temperature
range for 44°F. to -10°F. (See figure 1
for settings). The switching action is
single pole/double throw, opening on
temperature rise and closing on
temperature fall, completing the
circuit through the thermostat.

CCZO-9 Effective 1/1/06


Cooling Only and Heating Only
Comfort Controls

Cooling Only
BAY28X186
• 0 Heat/2 Cool
• Can be Used for Economizer Operation
• Use with BAY28X187 Subbase only
• Off/Auto System Switch
Subbase is required
• Auto/On Fan Switch
(shown with 187 subbase)
• Clear Plastic Set Point Lever
• Thermometer can be Calibrated
• Finish: Beige and Gold

Cooling Only
BAYSTAT304
• 0 Heat/1 Cool
• Off/Auto/Fan System Switch
• Clear Plastic Set Point Lever
• Finish: Bright White

Heating Only
BAYSTAT303
• 1 Heat/0 Cool
• Gas Heat Compatible
• Off/Auto/Fan System Switch
• Clear Plastic Set Point Lever
• Not Electric Heat Compatible
• Requires BAY24X042 Relay for
Indoor Fan Operation when used
for Electric Heat
• Adjustable Heat Anticipator
• Finish: Bright White

Effective 1/1/06 CCZO-10


Single Stage
Comfort Controls

Single Stage • Electric Heat Compatible; jumper


AY28X092 terminals 1 & 2 together
• 1 Heat/1 Cool • Calibrate by Adjusting the Cam
• Manual Changeover Rider Screw
• Heat/Off/Cool System Switch • Adjustable Heat Anticipator
• On Auto Fan Switch • Finish: Bright White
• Set Point Dial
• Gas Heat Compatible

Single Stage • Requires BAY24X042 Relay for


BAY28X182 Indoor Fan Operation when used
• 1 Heat/1 Cool for Electric Heat
• With BAY28X185 Subbase: • Clear Plastic Set Point Levers
Manual Changeover • Adjustable Heat Anticipator
Instant On Fan (for Electric Heat) • Thermometer can be Calibrated
Subbase is required
Heat/Off/Cool System Switch • Finish: Beige and Gold
(shown with 185 subbase) Auto/On Fan Switch
• With BAY28X187 Subbase:
Automatic Changeover
Off/Auto System Switch
Auto/On Fan Switch

Single Stage • Auto/On Fan Switch


BAYSTAT008 • Adjustable Heat Anticipator
• 1 Heat/1 Cool • Requires BAY24X042 Relay for
• Manual Changeover Indoor Fan Operation when used
• Includes Stat and Subbase for Electric Heat
• Set Point Dial • Finish: Gold
• Calibrate with Honeywell Calibration
Wrench (Part #104994A)
• Cool/Off Heat System Switch

Single Stage • Electric Heat Compatible; jumper


BAYSTAT305 terminals 1 & 2 together
• 1 Heat/1 Cool • Adjustable Heat Anticipator
• Manual Changeover • Finish: Bright White
• Heat/Off/Cool System Switch
• On Auto Fan Switch
• Clear Plastic Set Point Lever
• Gas Heat Compatible

CCZO-11 Effective 1/1/06


Multiple Stage
Comfort Controls

Multiple Stage • With BAY28X187 Subbase:


BAY28X183 Automatic Changeover
• 2 Heat/2 Cool-Can be Used for Off/Auto System Switch
Economizer Operation Auto/On Fan Switch
• With BAY28X184 Subbase: • Requires AY24X042 Electric Heat
Automatic or Manual Changeover Relay
Subbase is required
Off Heat/Auto/Cool System Switch • Clear Plastic Set Point Levers
(shown with 184 subbase) Auto/On Fan Switch • Adjustable Heat Anticipator
• Requires AY24X042 Electric Heat • Thermometer can be Calibrated
Relay • Finish: Beige and Gold
• With BAY28X185 Subbase:
Manual Changeover
Instant On Fan (for Electric Heat)
Heat/Off/Cool System Switch
Auto/On Fan Switch

Multiple Stage • Thermometer can be Calibrated


BAYSTAT010 • Adjustable Heat Anticipator
• 2 Heat/2 Cool-Can be Used for • Finish: Beige and Gold
Economizer Operation
• Automatic Changeover
• Includes Stat and Subbase
• Off/Auto System Switch
• Auto/On Fan Switch
• Clear Plastic Set Point Levers

Multiple Stage • Thermometer can be Calibrated


BAYSTAT012 • Adjustable Heat Anticipator
• 1 Heat/2 Cool-Can be Used for • Finish: Beige and Gold
Economizer Operation
• Manual Changeover
• Includes Stat and Subbase
• Heat/Off/Cool System Switch
• Auto/On Fan Switch
• Clear Plastic Set Point Levers

Multiple Stage • Requires AY24X042 (DPDT Relay) for


TAYSTAT241 indoor fan operation when used for
• 2 Heat/1 Cool Electric Heat
• Manual Changeover • Finish: Bright White
• For 2-stage Gas Furnaces
• Heat/Off/Cool System Switch
• Auto/On Fan Switch
• Clear Plastic Set Point Lever

Effective 1/1/06 CCZO-12


Heat Pump
Comfort Controls

Heat Pump • Clear Plastic Set Point Levers


BAY28X138A • Deluxe Clear Plastic Cover
• 2 Heat/1 Cool • Minimum differential between Heating
• Automatic Changeover and Cooling is 4°F
• Off/Auto System Switch • Thermometer can be Calibrated
• Auto/On Fan Switch • Finish: Bright White
• Normal/Emergency Heat Switch
• Auxiliary and Emergency Heat
Indicator Lights

Heat Pump • Used with System2


BAY28X153A • Deluxe Clear Plastic Cover
• 3 Heat/2 Cool • Clear Plastic Set Point Levers
• Automatic or Manual Changeover • Minimum differential between heating
• Can be Used for Economizer and cooling is 4°F
Operation • Thermometer can be Calibrated
• Auto Heat/Off/Cool System Switch • Includes Stat & Subbase
• High Auto Low Fan Switch • Finish: Bright White
• Normal Emergency Heat Switch
• Auxiliary and Emergency Heat
Indicator Lights

Heat Pump • Thermometer can be Calibrated


BAYSTAT239A • Clear Plastic Set Point Lever
• 2 Heat/1 Cool • Finish: Bright White
• Manual Changeover
• Includes Stat & Subbase
• Heat/Off/Cool System Switch
• Auto/On Fan Switch
• Normal/Emergency Heat Switch
• Auxiliary and Emergency Heat
Indicator Lights

Heat Pump • Thermometer can be Calibrated


BAYSTAT240A • Clear Plastic Set Point Lever
• 2 Heat/1 Cool • Finish: Bright White
• Manual Changeover
• Heat/Off/Cool System Switch
• Auto/On Fan Switch
• Normal Emergency Heat Switch
• Auxiliary and Emergency Heat
Indicator Lights

CCZO-13 Effective 1/1/06


Zone Comfort Controls

BAYSTAT040B • Keyboard disable to prevent tampering


• BAYBASE008A: Single Stage • 100% solid state
1 Heat/1 Cool • No outdoor thermostat required, utilizes
• BAYBASE006A: Multi Stage computer controlled staging (multistage)
2 Heat/2 Cool-Can be used for • Auto fan during setback (optional)
Economizer Operation • No anticipator required
• BAYBASE007A: Multi Stage • Automatic or Manual changeover
Heat Pump-3 Heat/2 Cool-Can be • Built-in minimum on-off time delays
used for Economizer Operation ensure short cycle protection
• Digital display indicating the time of • Lockable cover
day, the day of the week, room • Equipment short cycle protection against
temperature, current program operat- power outages longer than 1/2 second.
ing mode, and current active stage Equipment turns off for 6 minutes
• Instant override, continuous or • No accessories required. Each unit is
temporary 3 hour timed complete and ready for installation
• Automatic adjustment of temperatures • Finish: Bright White
up to four times a day
• L.C.D. readout in F or C (Celsius) and
12 or 24-hour clock
• Preferential Rate Control (PRC)
minimizes overshooting and prevents
room temperature deviating from
setpoint under varying load conditions
(zero droop)
• PRC provides smart recovery from
offset to minimize use of supplemental
electric heat

Remote Sensor
BAYSENS033A
• Remote Sensor for use with • Vendor: Honeywell
BAYSTAT040B • Finish: Bright White
• Allows convenient thermostat location
and optimum temperature sensing
location
• Maximum distance from thermostat
to sensor = 1000 ft.
• Use 3 conductor (18-26 AWG)
shielded, and insulated cable

BAYSENS034A
• Return Air Remote Temperature
Sensor for use with BAYSTAT040B

Effective 1/1/06 CCZO-14


ComfortLinkTM System

The System Controller Use:


• Two Piece Control
The Controller is the master and center hub of • Home Automation Interface "Open Protocol"
the system. It acquires information. From the • Extensive Diagnostics and Monitoring
information it gathers, it establishes the System
system's operation. The main functions of the
controller are communications, computation,
activation and control.
ZSCNTRAL010 Must be used with any ZUSTATAL** Wall Mounted Sensor.

Integrated ZoneTM System


Assembly and Accessories
• Full modulating zone operation • Wet-heat (hot water coil in air handler)
• Single and two-stage heating products compatible
• Single and two-stage cooling products • Zone card adjustable from 20 to 100%
• Indoor fan motors -- handles both Variable system airflow
Speed and PSC induction motors • By-pass offering
• Heat pump compatible • Relief to zones adjustment (standard
• Fossil fuel (gas and oil furnace) feature)
ZSASSMAL010 compatible

ZSASSMAL010: Zoning Assembly


Contains the Basic Control components (excluding wall mounted sensors) for either I) a three
(3) zone system, or II) a two (2) zone system with by-pass. Control Components included are
the system controller, one (1) four-zone expander board with three (3) zone cards. All mounted
in a metal enclosure that will accept an additional four-zone expander board for up to eight (8)
zones. Discharge Air Sensor is included and packaged in a 2x2x11 box. For single and two-
stage products (except XL16i); cooling, gas, oil, electric heat, and heat pump systems.

ZZEXPDAL010: Four-Zone Expander Board


Used to expand ZSASSMAL010 Basic Zoning Assembly up to eight (8) zones or seven (7)
zones with by-pass.

ZZCARDAL010: Zone/By-Pass Card


Controls a single zone's damper(s) or the by-pass damper. Zone and by-pass airflows are set
on each card. One card required per zone.

Note: XL16i models, both cooling or heat pump models, are not approved for Trane Comfort Link™ Zoning System.

CCZO-15 Effective 1/1/06


Sensors For
Trane ComfortLinkTM System

• Continuously Displays: • Backlight Display • Outdoor Temperature Display


– Indoor Temperature • Battery Backup upon Request (TAYSTAT265B
– Thermostat Mode • Programmable Setback (Four Set Points) Sensor Required)
– Programmable • Must be applied with ZSCNTRAL010 • Finish: Bright White
– Fan Mode • Seven Day Programming *When used as a Two Piece
ZUSTATALMS10 – Time of Day • Temporary Program Override Control, ZSCNTRAL010 Must
– Day of Week • Hold Set Point be Applied
– System Staging
– Active Program
Slimline Wall Mount Zone Scheduler/Programmable Display Sensor: Same features as ZUSTATALP510 sensor.
Can be used to program and schedule up to eight (8) zones. Copy button for ease of programming time/temperature
schedules from other zones. Use with ZSASSMAL010 only.

• Continuously Displays: • Backlight Display • Outdoor Temperature Display


– Indoor Temperature • Battery Backup upon Request (TAYSTAT265B
– Thermostat Mode • Programmable Setback (Four Set Points) Sensor Required)
– Programmable • Must be applied with ZSCNTRAL010 • Finish: Bright White
– Fan Mode • Seven Day Programming *When used as a Two Piece
Programmable – Time of Day • Temporary Program Override Control, ZSCNTRAL010 Must
Sensor – Day of Week • Hold Set Point be Applied
ZUSTATALP510 – System Staging
– Active Program
Slimline Wall Mount Programmable Display Sensor: Same basic features as ZUSTATALS510 sensor with seven day
schedule programming which allows four separate time/tempeature settings per 24-hour period. Backlit LCD for easy view
and programming. Displays day of week in addition to time and temperature. Use with either ZSASSMAL010 or
ZSCNTRAL010.

• Continuously Displays: • Backlight Display *When used as a Two Piece Control,


– Indoor Temperature • Battery Backup ZSCNTRAL010 Must be Applied
– Thermostat Mode • Must be applied with ZSCNTRAL010
– Fan Mode • Outdoor Temperature Display upon
– Time of Day Request (TAYSTAT265B Sensor
Non-Programmable – Day of Week Required)
Sensor – System Staging • Finish: Bright White
ZUSTATALS510
Slimline Wall Mount Display Sensor: Comfort sensor continuously displays the time and indoor temperature backlit
LCD for easy view. Used to change indoor temperature settings and conditioning modes. When used with
TAYSTAT265B sensor, outdoor temperature can be viewed. Use with either ZSASSMAL010 or ZSCNTRAL010.

• Continuously Displays: • Outdoor Temperature Display upon • Finish: Bright White


– Indoor Temperature Request (TAYSTAT265B Sensor
– Thermostat Mode Required)
– Fan Mode • Must be applied with ZSCNTRAL010
Petite Wall Mount Display Sensor: Slimline design comfort sensor continuously displays indoor temperature. Used to
Communicating change indoor temperature settings and conditioning modes for cool, heat, auto, or continuous fan. When used with
Comfort Sensor TAYSTAT265B sensor, outdoor temperature can be viewed. Used with either ZSASSMAL010 or ZSCNTRAL010. Not
ZUSTATAL0310 backlit.

• Remote Sensor for: • Finish: Bright White


– ZUSTATALS51
– ZUSTATALP51
– ZUSTATALMS10
Remote Analog Temperature Sensor: Temperature only sensor. Senses the temperature where located. When used
Room/Remote for a zone temperature sensor, must be used with ZUSTATALMS1 Master Scheduler. Can be used as a remote sensor
Sensor for ZUSTATALS51, ZUSTATALP51, or ZUSTATALMS1.
ZZSENSAL011
or
Outoor Temperature • Outdoor Sensor for: • Finish: Bright White
Sensor – ZUSTATALS51
TAYSTAT265B – ZUSTATALP51

Outdoor Temperature Sensor: Outdoor temperature only sensor. Can be used with ZUSTATALS51, ZUSTATALP51, or
ZUSTATALMS1. Weather proofed.

Effective 1/1/06 CCZO-16


Integrated ZoneTM System
Dampers

• Fully modulating damper • 60 second travel time


• Low power requirement 2.5 VA @ 24v • Manual gear release
• Factory mounted motor actuator • Color coded wiring harness for easy field
• 53 inch-pound running torque hook-up
• 40 inch-pound break away torque • Low leakage Trane design
• Magnetic clutch for torque protection • 18 guage construction
• Adjustable rotation stops allow for minimum/ • 24 volt operation
maximum airflow
Table CCZO-17-A — Specifications: Round Dampers
Model Power Fits Round Mfg. Shipping
Number Supply Description Duct Size Plant Weight Diameter Length
ZD0006ALF0B0 24 VAC 6" Modulating Damper 6" TY 8 6.375 12.00
ZD0008ALF0B0 24 VAC 8" Modulating Damper 8" TY 10 8.375 12.00
ZD0010ALF0B0 24 VAC 10" Modulating Damper 10" TY 13 10.375 16.00
ZD0012ALF0B0 24 VAC 12" Modulating Damper 12" TY 15 12.375 16.00
ZD0014ALF0B0 24 VAC 14" Modulating Damper 14" TY 22 14.375 20.00
ZD0016ALF0B0 24 VAC 16" Modulating Damper 16" TY 24 16.375 20.00

W • Bottom mount actuator motor • Manual gear release


• Low power requirement 2.5 VA @ 24v • Color coded wiring harness for easy field
• Fully modulating damper hook-up
• Factory mounted motor actuator • Low leakage Trane design
• 53 inch-pound running torque • 18 guage construction
• 40 inch-pound break away torque • 24 volt operation
H • Long life PTC High Impact ABS gears
• Magnetic clutch for torque protection
• Adjustable rotation stops allow for minimum/ designed and tested to exceed 200,000
maximum airflow cycles
• 60 second travel time

Table CCZO-17-B — Specifications: Rectangular Dampers with Bottom Mount Actuator


Uncrated
Model Power Dimensions (in.) Mfg. Shipping
Number Supply Description H W Plant Weight
ZD0810ALBMB0 24 VAC 8" height x 10" width 8 10 TY 16
ZD0814ALBMB0 24 VAC 8" height x 14" width 8 14 TY 20
ZD0820ALBMB0 24 VAC 8" height x 20" width 8 20 TY 26
ZD1014ALBMB0 24 VAC 10" height x 14" width 10 14 TY 28
ZD1020ALBMB0 24 VAC 10" height x 20" width 10 20 TY 35

• Side mount actuator motor • Manual gear release


• Low power requirement 2.5 VA @ 24v • Color coded wiring harness for easy field
• Fully modulating damper hook-up
• Factory mounted motor actuator • Low leakage Trane design
H • 53 inch-pound running torque • 18 guage construction
• 40 inch-pound break away torque • 24 volt operation
• Magnetic clutch for torque protection • Long life PTC High Impact ABS gears
• Adjustable rotation stops allow for minimum/ designed and tested to exceed 200,000
maximum airflow cycles
• 60 second travel time

W Table CCZO-17-C — Specifications: Rectangular Dampers with Side Mount Actuator


Uncrated
Model Power Dimensions (in.) Mfg. Shipping
Number Supply Description H W Plant Weight
ZD0812ALSMB0 24 VAC 8" height x 12" width 8 12 TY 17
ZD0814ALSMB0 24 VAC 8" height x 14" width 8 14 TY 20
ZD0816ALSMB0 24 VAC 8" height x 16" width 8 16 TY 22
ZD0818ALSMB0 24 VAC 8" height x 18" width 8 18 TY 24
ZD0820ALSMB0 24 VAC 8" height x 20" width 8 20 TY 26
ZD1016ALSMB0 24 VAC 10" height x 16" width 10 16 TY 29
ZD1020ALSMB0 24 VAC 10" height x 20" width 10 20 TY 35

CCZO-17 Effective 1/1/06


Zone Sensor Unit
Installation

The zone sensor provides the operator ZONE SENSOR CONTROLS


control and zone temperature sensing
functions for use with electronic unit
controls. Refer to the appropriate unit
Emergency Heat/Heat/Auto/
installation manual for interconnecting Off/Cool
wiring instructions. This switch determines whether the
unit operates in emergency heat (EM.
HEAT - for heat pumps only), heating
ZONE SENSOR LOCATION (HEAT), automatically changing from
heating to cooling as required (AUTO),
To ensure proper operation, select a heating and cooling functions disabled
location on an interior wall, at a height (OFF), or cooling (COOL).
approximately 5 feet above the floor,
with freely circulating air of average Fan Auto/Fan On
temperature. This switch determines whether the
indoor fan operates during cooling and
heating cycles only (FAN AUTO) or
Avoid Locations: runs continuously (FAN ON).
• Behind doors or in corners where air
does not freely circulate.
Temperature Adjustments
One or two temperature adjustment
• On an outside wall or any wall with controls are provided to set the
unheated (uncooled) areas behind the desired temperature or temperature
zone sensor. range (for unit mode AUTO). If two
• Where direct sunlight or any Source: of controls are present, the blue control
radiant heat could affect the sets the desired temperature for
temperature measurements. cooling and the red control sets the
desired temperature for heating.
• In line with the discharge air from the
unit being controlled.
Temperature Indicator
Mount the zone sensor base on the This indicates the temperature in the
wall or optional mounting plate with the zone. The indicator has been factory
wires routed through the wire access calibrated and should not normally
hole in the base of the zone sensor. require adjustment. If adjustment is
needed, it can be accomplished by
slowly rotating a small screwdriver in
the slot on the back of the indicator
until the correct temperature is
obtained.

Optional Remote Sensor


When using the optional remote
sensor (BAYSENS017B), it should be
located in the space that is to be
controlled. Wire according to the
interconnecting wiring diagrams in the
unit IOM.

Installation: 18-HD60D41
Source: Clarksville

Effective 1/1/06 CCZO-18


Micro Controls
Zone Sensors

LCD Digital • 7 wires required.


Display Zone Sensor • Non-Programmable Zone Sensor with
BAYSENS035A/031A a digital display
• Used with 3-25 ton packaged units.
• BAYSENS035A - Cool/Gas
• BAYSENS031A - Heat Pumps

Averaging Remote • Refer to IOM for wires required


Zone Sensor • Zone Sensor averaging only
BAYSENS032A • Application where two wall mounted
sensors are required
• BAYSENS032A used with 3-25 Ton
packaged Gas/Cool/Heat Pumps

Electronic Programmable Zone


Sensors For ReliaTel TM Units

BAYSENS019C • Keyboard disable to prevent tampering


• Automatic or Manual Changeover • Programming on a 7-day basis
with System Lights • Status indication lights displayed in
• Use With: Digital Display
3 – 10 Ton Precedent™ Units • Auxiliary relay (Form 1C)
MODE

12.5 – 25 Ton Voyager™ Units • Auto Fan During Setback


• Digital display indicating the time of • No Anticipator Required
day, the day of the week, room • No Battery Required
temperature, current program operat- • No accessories required. Each unit is
ing mode, and current active stage complete and ready for installation
• Continuous or 3 hour timed override • Remote Room Sensor (BAYSENS017B)
• Two occupied, two unoccupied • Vendor: Heatcraft 63J74
programs per day • Finish: Pantone Cool Gray #2C
• L.C.D. readout in F or C (Celsius) and • Replacement: SEN-0415
12 or 24-hour clock • Installation: 18-HD60D29
• Source: Clarksville

CCZO-19 Effective 1/1/06


Electronic Zone Sensors For
ReliaTelTM Units

BAYSENS006B • Blue Cool/Red Heat Setpoint Levers


• Single Setpoint • Single Setpoint requires 4 wires for
• Manual Changeover Electric/Electric
• Use With: • Vendor: Sunne (62822)
3 – 10 Ton Precedent™ Units T*C, Y*C • Finish: Pantone Cool Gray #2C
12.5 – 25 Ton Voyager™ Units • Replacement: SEN-0410
YCD/YCH & TCD/TCH • Installation – 18-HD60D28
• Heat/Off/Cool System Switch • Source: Clarksville
• Auto/On Fan Switch

BAYSENS007B • Heat Indicator Light


• Single Setpoint • Blue Cool/Red Heat Setpoint Levers
• Manual Changeover • Single Setpoint for heat pumps systems
• Use With: requires 6 wires
3 – 10 Ton Precedent™ Units WSC • Vendor: Sunne (62821)
12.5 – 20 Ton Voyager™ Units WCD\WCH • Finish: Pantone Cool Gray #2C
• Heat/Off/Cool System Switch • Replacement: SEN-0411
• Auto/On Fan Switch • Installation – 18-HD60D33
• Normal/Emergency Heat Switch • Source: Clarksville

BAYSENS008B • Auto/On Fan Switch


• Dual Setpoint • Blue Cool/Red Heat Setpoint Levers
• Manual or Auto Changeover • Vendor: Sunne (62826)
• Use With: • Finish: Pantone Cool Gray #2C
3 – 10 Ton Precedent™ Units T*C, Y*C • Replacement: SEN-0408
12.5 – 25 Ton Voyager™ Units • Installation – 18-HD60D34
YCD/YCH & TCD/TCH • Source: Clarksville
• Heat/Auto/Off/Cool Switch

BAYSENS009B • Normal/Emergency Heat Switch


• Dual Setpoint • Heat Indicator Light
• Manual or Auto Changeover • Blue Cool/Red Heat Setpoint Levers
• Use With: • Vendor: Sunne (62825)
3 – 10 Ton Precedent™ Units WSC • Finish: Pantone Cool Gray #2C
12.5 – 20 Ton Voyager™ Units WCD\WCH • Replacement: SEN-0412
• Heat/Auto/Off/Cool Switch • Installation – 18-HD60D35
• Auto/On Fan Switch • Source: Clarksville

BAYSENS010B • System On/Heat/Cool/Service


• Dual Setpoint Indicator Lights
• Manual or Auto Changeover • Blue Cool/Red Heat Setpoint Levers
• Use With: • Vendor: Sunne (62823)
3 – 10 Ton Precedent™ Units T*C, Y*C • Finish: Pantone Cool Gray #2C
12.5 – 25 Ton Voyager™ Units YCD/YCH & • Replacement: SEN-0413
TCD/TCH • Installation – 18-HD60D36
• Heat/Auto/Off/Cool Switch • Source: Clarksville
• Auto/On Fan Switch

Effective 1/1/06 CCZO-20


Electronic Zone Sensors For
ReliaTelTM Units

BAYSENS011B • Normal/Emergency Heat Switch


• Dual Setpoint • System On/Heat/Cool/Service
• Manual or Auto Changeover Indicator Lights
• Use With: • Blue Cool/Red Heat Setpoint Levers
3 – 10 Ton Precedent™ Units WSC • Vendor: Sunne (62824)
12.5 – 20 Ton Voyager™ Units • Finish: Pantone Cool Gray #2C
WCD\WCH • Replacement: SEN-0414
• Heat/Auto/Off/Cool Switch • Installation – 18-HD60D37
• Auto/On Fan Switch • Source: Clarksville

BAYSENS017B • Vendor: Sunne (62828)


• Remote Zone Sensor • Finish: Pantone Cool Gray #2C
• Use With: • Replacement: SEN-0435
BAYSENS006, 007, 008, 009, 010B, • Installation – 18-HD60D41
011B • Source: Clarksville
• Allows remote zone monitoring with
standard electronic zone sensors

Integrated ComfortTM Systems


Sensors For ReliaTel TM Units

BAYSENS013C • Vendor: Sunne (65464)


• Room Sensor with Timed Override • Finish: Pantone Cool Gray #2C
• Use with Integrated ComfortTM • Replacement: SEN-0495
Systems • Installation – 18-HD60D38
• Use With: • Source: Clarksville
3 – 10 Ton Precedent Units
12.5 – 25 Ton Voyager™ Units
• Timed Override Buttons

BAYSENS014C • Timed Override Buttons


• Room Sensor with Setpoint • Thumbwheel Setpoint
Adjustment • Vendor: Sunne (65465)
• Used with Integrated ComfortTM • Finish: Pantone Cool Gray #2C
Systems • Replacement: SEN-0496
• Use With: • Installation – 18-HD60D39
3 – 10 Ton Precedent Units • Source: Clarksville
12.5 – 25 Ton Voyager™ Units

CCZO-21 Effective 1/1/06


Ductless Air Conditioners

• Low sound levels through improved fan • Washable Grille.


and motor. • Lightweight and compact size.
• Precise Airflow through unique wide air • Powerful mode for 20 minute maxi-
diffusion system. mum output.
• Three stage air filter for improved Indoor • Cooling, Dehumidify (Dry), and Fan-
Air Quality (IAQ). Only modes
• Flexibility to be matched with 10 SEER
and 12 SEER condensing units.

Table MINI-1-A – Ductless High Wall - Cooling Only


Sound Uncrated
Model Nominal Level Dimensions(in.) Shipping
Number Airflow (L, H) H xW x D Weight
MCW509AMUA 265 31, 36 10.8 x 30.9 x 7.3 17.6
MCW512AMUA 310 31, 39 10.8 x 30.9 x 7.3 17.6
MCW518AMUA 520 36, 43 11.8 x 41.3 x 7.5 26.4
MCW524AMUA 525 38, 46 11.8 x 41.3 x 7.5 26.4
MCW530AMUA 600 37, 41 14.2 x 61.8 x 7.9 59.5
MCW536AMUA 800 41, 45 14.2 x 66.5 x 7.9 61.7

Table MINI-1-B – Accessories – Remote Controller Options (MCW530 & MCW536)1


Model Number Description H W D
RAYSTAT020A ............ Wired Remote Controller ............... 4.8 ......... 4.8 ......... 0.7
RAYSTAT021A ............ Wireless Remote Controller ........... 6.2 ......... 2.4 ......... 0.7

Table MINI-1-C – Accessories – Expansion Device (Orifice) (All Sizes)1


Model Model Used
Number Description With Size
BAYOFKT001 .... Metering Device (Orifice) ..... MCW512-18 ..... .043/.046
BAYOFKT002 .... Metering Device (Orifice) ....... MCW524 ............ .047
BAYOFKT003 .... Metering Device (Orifice) ....... MCW530 ............ .057
BAYOFKT004 .... Metering Device (Orifice) ....... MCW536 ............ .063

Table MINI-1-D – Accessories – Low Voltage Transformer (All Sizes)1


Model Model Used
Number Description With
BAYHVLV001 ...... 208-240/24V Transformer ............ All
1 Required for unit operation with TTB, 2TTB2 condensing units. Not required with TTK condensing units.

For complete equipment / combination


selections and installation instructions, please MINI-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Ductless Outdoor Units

• 9000 Btu model available • 10-12 SEER depending upon


• Low sound levels capacity
• Reduced installation time • Installation flexibility

Table MINI-2-A – Ductless Outdoor Unit - Cooling Only


Nom. Cap. Uncrated Line Size
Model Power Cooling Dimensions(in.) Shipping Sound Max OD OD
Number Supply (BTUH) H W D Weight Rating MCA* Fuse* Gas Liq.
TTK509E5UA 208-230/1/60 9,000 20 28 10 66 53 6.6 10 3/8 1/4
TTK512E5UA 208-230/1/60 12,000 20 28 10 77 53 7.3 12 1/2 1/4
TTK518E5UA 208-230/1/60 18,000 29 33 13 121 58 11.7 20 1/2 1/4
TTK524E5UA 208-230/1/60 24,000 29 33 13 141 62 14.5 25 5/8 1/4
TTK530E5UA 208-230/1/60 30,000 29 33 13 163 62 21.5 35 5/8 3/8
TTK536E5UA 208-230/1/60 36,000 29 33 13 168 64 26 45 3/4 3/8

Table MINI-2-B – Optional Accessories:


Model Model Used
Number Description With
BAYLOAMM001A Low Ambient Kit TTK509-512
BAYLOAMM002A Low Ambient Kit TTK518-536

For complete equipment / combination


Effective 1/1/06 MINI-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Packaged Terminal
Air Conditioners And Heat Pumps

Table PTAC/UH-1-A — Packaged Terminal Air Conditioner


Power Supply Cooling Cabinet Shipping
Chassis Volts/Phase/Hz Capacity EER kW H xW x D Weight
PTED0701D*A 208-230/1/60 7,000 12.5 2.0 16 1/6 x 42 x 13 ¾ 102
PTED0701G*A 208-230/1/60 7,000 12.5 3.5 16 1/6 x 42 x 13 ¾ 102
PTED0701W*A5 208-230/1/ 60 7,000 12.5 N/A 16 1/6 x 42 x 13 ¾ 102
PTED0901D*A 208-230/1/ 60 9,000 11.6 2.0 16 1/6 x 42 x 13 ¾ 103
PTED0901G*A 208-230/1/ 60 9,000 11.6 3.5 16 1/6 x 42 x 13 ¾ 103
PTED0901W*A5 208-230/1/ 60 9,000 11.5 N/A 16 1/6 x 42 x 13 ¾ 103
PTED0902D*A 265/1/60 9,000 11.5 2.0 16 1/6 x 42 x 13 ¾ 103
PTED0902G*A 265/1/60 9,000 11.5 3.7 16 1/6 x 42 x 13 ¾ 103
PTED1201G*A 208-230/1/60 12,000 11.2 3.5 16 1/6 x 42 x 13 ¾ 109
PTED1201J*A 208-230/1/60 12,000 11.2 5.0 16 1/6 x 42 x 13 ¾ 109
PTED1201W*A5 208-230/1/60 12,000 11.2 N/A 16 1/6 x 42 x 13 ¾ 109
PTED1202G*A 265/1/60 12,000 11.2 3.7 16 1/6 x 42 x 13 ¾ 110
PTED1501G*A 208-230/1/60 15,000 10.2 3.5 16 1/6 x 42 x 13 ¾ 117
PTED1501J*A 208-230/1/60 15,000 10.2 5.0 16 1/6 x 42 x 13 ¾ 117
PTED1501W*A5 208-230/1/60 15,000 10.2 N/A 16 1/6 x 42 x 13 ¾ 117
PTED1502G*A 265/1/60 15,000 10.0 3.7 16 1/6 x 42 x 13 ¾ 118

Table PTAC/UH-1-B — Packaged Terminal Heat Pump with Electric Heat


Power Supply Cooling Cabinet Shipping
Chassis Volts/Phase/Hz Capacity EER kW H xW x D Weight
PTHD0701D*A 208-230/1/60 7,000 12.2 2.0 16 1/6 x 42 x 13 ¾ 102
PTHD0701G*A 208-230/1/60 7,000 12.2 3.5 16 1/6 x 42 x 13 ¾ 102
PTHD0901D*A 208-230/1/60 9,000 11.2 2.0 16 1/6 x 42 x 13 ¾ 109
PTHD0901G*A 208-230/1/60 9,000 11.2 3.5 16 1/6 x 42 x 13 ¾ 109
PTHD0902D*A 265/1/60 9,000 11.2 2.0 16 1/6 x 42 x 13 ¾ 109
PTHD0902G*A 265/1/60 9,000 11.2 3.7 16 1/6 x 42 x 13 ¾ 109
PTHD1201G*A 208-230/1/60 12,000 10.3 3.5 16 1/6 x 42 x 13 ¾ 110
PTHD1201J*A 208-230/1/60 12,000 10.3 5.0 16 1/6 x 42 x 13 ¾ 110
PTHD1202G*A 265/1/60 12,000 10.7 3.7 16 1/6 x 42 x 13 ¾ 110
PTHD1501G*A 208-230/1/60 15,000 9.7 3.5 16 1/6 x 42 x 13 ¾ 110
PTHD1501J*A 208-230/1/60 15,000 9.7 5.0 16 1/6 x 42 x 13 ¾ 118
PTHD1502G*A 265/1/60 15,000 9.3 3.7 16 1/6 x 42 x 13 ¾ 118
Notes:
1 All units ship with cord and plug.
2 265 volt units require either a subbase or a hard wire junction box kit to be U.L. approved.
3 All units are ARI listed, C.U.L. and U.L. approved.
4 All units include a cord with plug, unit mounted control, built in front desk control terminals (wiring kit is required) temperature
limiter, room freeze protection, fan cycle switch, compressor time delay, cooling condensate removal and automatic emergency
heat stage thermostat on all heat pumps. Also all units have a built-in switch to change operation from unit mounted control to
remote, wall, mounted control.
5 Hydronic units ship with no electric heat and no plastic front cover. The hydronic kit, which must be ordered separately, includes a
metal front cover.

PTAC/UH-1 Effective 1/1/06


Packaged Terminal
Air Conditioners And Heat Pumps

Table PTAC/UH-2-A — Accessories


Description and Usage Sleeves Order Number
Standard Wall Sleeve WS130
Extended 18" Wall Sleeve WS180
Extended 24" Wall Sleeve WS240
Note: To be ordered for all installations except where existing wall sleeves are used.
Drain Kit DRAIN
Note: Attaches to wall sleeve for controlled indoor or outdoor disposal of condensate to a field supplied drain system.
Grilles
Stamped Aluminum Grille - Single Pack SAG01
Stamped Aluminum Grilles - Ten Pack SAG10
Architectural Aluminum Grille - Anodized finish AAGAL
Architectural Aluminum Grille - Dark Bronze AAGDB
Architectural Aluminum Grille - Soft Dove AAGSD
Wall Sleeve Levelling Legs LVLG02
Note: Used when a subbase is not required, but, additional support and leveling is needed. The adjusting screw can be extended 2 inches with a maximum
distance from the bottom of the wall sleeve to screw base of 5 inches and a minimum distance of 3 inches.
Subbases
Subbase 230/208V, 20A SUB0120
Subbase 230/208V, 30A SUB0130
Subbase 265V, 20A SUB0220
Subbase 265V, 30A SUB0230
Note: Provides a space to tie into building wiring and also includes a receptacle to plug unit into. Gives additional leveling and support capabilities. Provides a
place for fuses, circuit breaker or mechanical disconnect to be mounted.
Power or Mechanical Disconnect Switch
Power Switch 230/208V, 30 A PS0130
Power Switch 265V, 30 A PS0230
Note: These above kits can be installed on hard wire junction box and provides a way to shut unit on and off. Check local codes for approval.
Circuit Breaker Kits
Circuit Breaker 15A CB0115
Circuit Breaker 20A CB0120
Circuit Breaker 30A CB0130
Note: The Circuit Breaker Kit can be installed on front of subbase and provides overcurrent protection and means of shutting unit on and off.
Control Panel Key Lock KEYLOK
Note: To prevent unauthorized access to unit control panel.
Fuse Holder Kits
Fuse Holder Kit 15A FUSE0115
Fuse Holder Kit 20A FUSE0120
Fuse Holder Kit 30A FUSE0130
Note: Cartridge fuse fits into receptacle with screw type cap. Installed at unit control panel or in subbase. Provides overcurrent protection.
Hard Wire Kit HWIREK
Note: This kit provides convenient space to make electrical connection to building wiring. Includes flexible conduit, and wire to make connection from unit
chassis.
Hydronic Chassis Option
Plastic Front Cover PFC01
Note: Use with hydronic chassis when hot water kit is not used.

Effective 1/1/06 PTAC/UH-2


Packaged Terminal
Air Conditioners And Heat Pumps

Table PTAC/UH-3-A — Accessories


Hydronic Kits Order Number
Hydronic Steam Heat Kit - 230/208V HSK01
Hydronic Steam Heat Kit - 265V HSK02
Hydronic Steam Heat Kit - 115V HSK04
Hydronic Water Heat Kit - 115V HWK04
Hydronic Water Heat Kit - 265V HWK02
Hydronic Water Heat Kit - 230/208V HWK01
Note: Hydronic kits are to be ordered with the hydronic heat chassis only. Kits come with valve and transformer.
Note: All valves for Hydronic and Steam are 24 volt and include an end switch.
Digital Wall Mounted Thermostats
1H/1C Digital Prog Tstat (4-wire Pwr Steal) TAYSTAT340
1H/1C Digital NonProg Tstat (4-wire Pwr Steal) TAYSTAT371
2H/1C Heat Pump Digital Prog Tstat TAYSTAT540
2H/1C Heat Pump Digital NonProg Tstat TAYSTAT570
Note: All Wall Mounted Thermostats will work with standard units. All units include a switch for changing from unit mounted operation to remote or wall
mounted operation. See notes for AUXWIRE.
Wire Harness Kit - 10 Pack AUXWIRE
Note: Required when Wall Mounted Thermostat or Zone Sensor is used.

Remote Zone Sensor ZONSENS


Note: This temperature sensor overrides standard unit mounted thermostat to allow temperature sensing on internal wall for more accurate temperature
control.
Remote Escutcheon Kits - 10 Pack REK10C
Note: This kit should be ordered whenever Wall Thermostats are ordered. This Kit includes a control cover plate, that will cover the normal unit mounted
nomenclature. This kit comes 10/pack. A wire harness kit should be ordered separate.
Condensate Pumps
Condensate Pump 230/208V CDP01
Condensate Pump 265V CDP02
Note: This kit is for Heat Pumps ONLY and includes a small pump that will remove condensate developed during the heat pump operation and transfer it to
the indoor coil for re-evaporation and to dissipate into the room, adding humidity to the room. This option cannot be used with Corrosion-Resistant Models.
This can be field installed but it is very time-consuming and it is our recommendation that you choose the factory installed option. Important, even with this
option if no overflow of condensate is permissible, the installation of an external or building internal drain system is recommended.
Spare Filters - 10 Pack FILTR10
Note: Using the field installed, permanent, cleanable filters will keep debris off of the coil and out of the air. Unit will operate more efficiently if filters are
changed regularly.

PTAC/UH-3 Effective 1/1/06


Indoor Gas Heating Products
Product Description Indoor Units

Propeller Fan Gas Unit Heater • “10 Year Non-Prorated Warranty” on


• Two-point Suspension the Heat Exchanger, Burners and
• Horizontal Louvers Draft Hood Assembly.
• 115/60/1 Open Drip-proof Motor with
Built-in T.O.P.
• 24V Control Transformer
• Junction Box for Power Wiring
• Single-Stage Automatic Gas Valve
• Standing Pilot
• Fan Time Delay Relay
• Aluminized Steel Heat Exchanger
• Blocked Vent (Spill) Switch

High Efficiency Propeller Fan Gas • “10 Year Non-Prorated Warranty” on


Unit Heater the Heat Exchanger, Burners and
• Two-point Suspension Draft Hood Assembly.
• Horizontal Louvers
• 115/60/1 Open Drip-proof Motor with
Built-in T.O.P.
• 24V Control Transformer
• Junction Box for Power Wiring
• Single-Stage Combination Gas Valve
• Intermittent Pilot Ignition
• Fan Time Delay Relay
• Aluminized Steel Heat Exchanger
• Factory Installed Flue Vent Fan
• Combustion Air Pressure Switch

Centrifugal Fan Gas Unit Heater • “10 Year Non-Prorated Warranty” on


• Horizontal Louvers the Heat Exchanger, Burners and
• 115/60/1 Open Drip-proof Motor with Draft Hood Assembly.
Built-in T.O.P.
• Adjustable V-belt Drive With Belt Guard
• 24V Control Transformer
• Junction Box for Power Wiring
• Single-Stage Automatic Gas Valve
• Standing Pilot
• Fan Time Delay Relay
• Aluminized Steel Heat Exchanger
• Blocked Vent (Spill) Switch

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-4 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Product Description Indoor Units

High Efficiency Centrifugal Fan Gas • Factory Installed Flue Vent Fan
Unit Heater • Combustion Air Pressure Switch
• Horizontal Louvers • “10 Year Non-Prorated Warranty”
• 115/60/1 Open Drip-proof Motor with on the Heat Exchanger, Burners
Built-in T.O.P. and Draft Hood Assembly.
• Fan Guard
• 24V Control Transformer
• Junction Box for Power Wiring
• Single-Stage Intermittent Pilot Ignition
• Fan Time Delay Relay
• Aluminized Steel Heat Exchanger

Indoor Gas Duct Furnace Note: A drain pan is not included.


• Blow Through Applications Only! See field installed options.
• 24V Control Transformer
• Junction Box For Power Wiring
• Single-Stage Automatic Gas Valve
• Standing Pilot
• Aluminized Steel Heat Exchanger
• 10 year warranty “does not apply.”
Trane’s standard 12/18 month only.
• Blocked Vent (Spill) Switch

High Efficiency Indoor Gas Duct Note: A drain pan is not included.
Furnace See field installed options.
• Blow Through Applications Only
• 24V Control Transformer
• Junction Box For Power Wiring
• Single-Stage Combination Gas Valve
• Intermittent Pilot Ignition
• Aluminized Steel Heat Exchanger
• Factory Installed Flue Vent Fan
• Combustion Air Pressure Switch
• 10 year warranty “does not apply.”
Trane’s standard 12/18 month only.

Horizontal Blower Assembly


• Junction Box For Power Wiring
• Filter Rack and 1” Permanent Filters
• Adjustable V-Belt Drive
• 10 year warranty “does not apply.”
Trane’s standard 12/18 month only.

Contact Macon Product Support for more


The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-5 Effective 1/1/06
Indoor Gas Heating Products
Indoor Units

Table PTAC/UH-6-A — Propeller Fan Gas Unit Heaters


Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040
MBh (input) 30 45 60 75 100 125 150 175 200 225 250 300 350 400
MBh (output) 24.3 36.5 48.6 60.8 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Propeller Fan Alum
Unit Heater 409SS
GPND or GPPD 321SS — — — —
Std. 115/60/1 motor hp 1/30 1/30 1/30 1/30 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2)1/4 (2)1/3 (2)1/3
Notes:
Approved in California when ordered with intermittent pilot ignition.

Table PTAC/UH-6-B — High Efficiency Propeller Fan Unit Heater


Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040
MBh (input) 30 45 60 75 100 125 150 175 200 225 250 300 350 400
MBh (output) 24.9 37.4 48.0 60.0 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
High Eff Prop Alum
Fan U.H. 409SS
GHND or GHPD 321SS — — — —
Std 115/60/1 motor hp 1/30 1/30 1/30 1/30 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2)1/4 (2)1/3 (2)1/3
Notes:
1. The only gas control option available is single stage intermittent pilot. This is included in the list price of the unit.
2. 115V flue vent fans are factory installed and included in the list price of the unit.

Table PTAC/UH-6-C — Separated Combustion Propeller Fan Gas Unit Heater


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Sep. Comb. Alum
Fan U.H. 409SS
GAND or GAPD 321SS
Std 115/60/1 motor hp 1/20 1/10 1/4 1/3 1/3 1/3 1/3 (2) 1/4 (2) 1/3 (2) 1/3
Notes:
1. Single stage intermittent pilot ignition is standard and included in the list price of the unit. Two-stage intermittent pilot is available as an option.
2. 115V factory installed flue vent fan is included in the list price of the unit.

Table PTAC/UH-6-D — Centrifugal Fan Gas Unit Heaters


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Centrifugal Fan Alum
Unit Heater 409SS
GCND or GCPD 321SS
Std 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1
Notes:
1. Includes standard 115/60/1 open drip-proof motor.
2. If other than standard voltage required, deduct standard motor and add required motor.
3. Contact Macon Product Support if motor size other than standard size is required.
4. Approved in California when ordered with intermittent pilot ignition.
5. If ordering a flue vent fan (460V units) add transformer list add shown in flue vent fan table.

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-6 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Indoor Units

Table PTAC/UH-7-A — High Efficiency Centrifugal Fan Gas Unit Heater


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
High Eff. Cent. Alum
Fan U.H. 409SS
GBND or GBPD 321SS
St. 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1
Notes:
1. Includes standard 115/60/1 open drip-proof motor.
2. If other than standard voltage is required, deduct standard motor and add required motor.
3. 115V flue vent fans are standard and included. If other than standard voltage is required, include a Line/115V transformer.
4. Contact Macon Product Support, if motor size other than standard is required.

Table PTAC/UH-7-B — Separated Combustion Centrifugal Fan Gas Unit Heater


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Sep. Comb. Cent. Alum
Fan U.H. 409SS
GKND or GKPD 321SS
Std 115/60/1 motor hp 1/4 1/3 1/2 1/2 3/4 3/4 3/4 3/4 1 1
Notes:
1. Includes standard 115/60/1 open drip-proof (ODP) motor.
2. If other than standard voltage is required, deduct standard motor and add required motor.
3. Includes single-stage intermittent pilot ignition and a 115V factory installed flue vent fan. If other than standard voltage is required, include a line/115V transformer.
4. Two-stage intermittent pilot ignition is available as an option.
5. Contact Macon Product Support if motor size other than standard is required.

Table PTAC/UH-7-C — Indoor Gas Duct Furnaces


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 280.0 320.0
Indoor Duct Alum
Furnace 409SS
GDND or GDPD 321SS
Notes:
Duct Furnaces are approved only in blow-thru applications.
If a duct furnace is being used with an HBAC — the main power supply must be the same. The duct furnace includes a Line to 24V control transformer.

Table PTAC/UH-7-D — High Efficiency Gas Duct Furnaces


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80 100 120 140 160 180 200 240 280 320
High Eff Indoor Alum
Duct Furnace 409SS
GLND or GLPD 321SS
Notes:
1. Includes single-stage intermittent pilot.
2. Includes 115/24V control transformer. No other voltage selection available.
3. 115V flue vent fans are factory installed.
4. Approved in the blow-thru applications only.

Contact Macon Product Support for more


The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-7 Effective 1/1/06
Indoor Gas Heating Products
Indoor Units

Table PTAC/UH-8-A — Separated Combustion Duct Furnaces


Unit Size 010 012 015 017 020 022 025 030 035 040
MBh (input) 100 125 150 175 200 225 250 300 350 400
MBh (output) 80.0 100.0 120.0 140.0 160.0 180.0 200.0 240.0 260.0 320.0
Sep. Comb. Alum
Duct Furnace 409SS
GMND or GMPD 321SS
Notes:
1. Includes single-stage intermittent pilot.
2. Includes 115/24V control transformer. No other voltage selection available.
3. 115V flue vent fans are factory installed.
4. Approved in the blow-through applications only.

Table PTAC/UH-8-B— Tubular Heat Exchanger, Propeller Gas Unit Heater


Unit Size 003 004 006 007 009 010 012 015 017 020 025 030 035 040
MBh (input) 30 45 60 75 90 100 125 150 175 200 250 300 350 400
MBh (output) 24.3 36.5 48.6 60.8 72.9 81.0 101.3 121.5 141.7 162.0 202.5 243.0 283.5 324.0
Tubular Heat Exc. Alum
GTND or GTPD
Std. 115/60/ motor hp 1/20 1/20 1/20 1/20 1/20 1/10 1/4 1/4 1/3 1/3 1/3 1/4 1/3 1/3
Notes:
1. Units only available with Aluminized Heat Exchanger, stainless steel not available or required.
2. Factory installed flue vent fan is included.
3. The gas control is single stage, hot surface pilot ignition and is included in the unit.
4. Size 225 MBh units are not available.

Table PTAC/UH-8-C — Tubular Heat Exchanger - Residential Propeller Fan Gas Unit Heater
Unit Size R03 R04 R06 R07 R09
MBh (input) 30 45 60 75 90
MBh (output) 24.3 36.5 48.6 60.8 72.9
Tubular - Residential Alum
GTND or GTPD
Std. 115/60/1 motor hp 1/20 1/20 1/20 1/20 1/20
Notes:
1. Includes standard 115/60/1 open drip-proof (ODP) motor. If totally enclosed 115/60/1 motors are required.
2. Units only available with Aluminized Heat Exchanger, stainless steel not available or required.
3. Factory installed flue vent fan is included.
4. The only gas control option available is single stage, hot surface pilot ignition. This is included in the unit.
5. Includes spil or flame roll out switch.
6. Includes OSHA Fan Guard.

Table PTAC/UH-8-D — Horizontal Blower Assembly


Horizontal Unit Size 15 20 030 045
Blower Duct Furnace Size Used With 010, 012 015, 017 020, 022, 025 030, 035, 040
Assembly Unit —
HBAC Transition 48 48 48 48
Note:
Does not include motor. Motor from Table PTAC/UH-9-A must be added to unit.

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-8 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Indoor Unit Options
(Factory Installed)
Table PTAC/UH-9-A —Motor Prices
Voltage 1/4 hp 1/3 hp 1/2 hp 3/4 hp 1 hp 1-1/2 hp 2 hp
115/60/1 - Open
230/60/1 - Open
208/60/3 - Open —
230/60/3 - Open —
460/60/3 - Open —
575/60/3 - Open — —
115/60/1 -T.E.
230/60/1 -T.E.
208/60/3 -T.E. —
230/60/3 -T.E. —
460/60/3 -T.E. —
575/60/3 -T.E. — —
Shipping Wt. 51 55 55 57 57 75 88
motor prices — for totally enclosed motors for Propeller Fan Unit Heaters only andTubular Units
Voltage 1/3 hp 1/20 hp 1/10 hp 1/4 hp 1/3 hp 1/4 hp 1/3 hp
Unit sizes 003 004 006 007 10 12 15 017 020 022 025 30 035 040
R03, R04, R06, R07, R09
115/60/1
Note:
Contactors not required on any units provided with single phase motors up to 1 hp. Low voltage contactors are included on all units with single phase 11/2 hp and above motors and
on all three-phase motors.

Table PTAC/UH-9-B —Gas Control Options


Pilot — GasType Control Designator
Standard Standing Pilot — Single-Stage A**
Propeller, Duct and Natural or LP (Propane) Gas Hydraulic Modulating1 C
Centrifugal Units Only Intermittent Pilot — Single-Stage D
(GP, GC, GD) Natural or LP (Propane) Two-Stage4 E
Gas Hydraulic Modulating1,4 F
Hydraulic Modulating w/Bypass1,4 G
Intermittent — Pilot — Electronic Modulating — Room Stat H
Natural or LP (Propane) Gas Electronic Modulating — Duct Stat5 J
Electronic Modulating w/External L
4-20 mA Input
Electronic Modulating w/External N
0-10 VDC Input
High Efficiency Intermittent Pilot Single-Stage D**
Units — Propeller, Natural or LP (Propane) Gas Two-Stage4 E
Centrifugal and Duct Hydraulic Modulating1,4 F
Furnaces Only Hydraulic Modulating w/Bypass1,4 G
(GH, GB, GL) Intermittent Pilot — Electronic Modulating — Room Stat4 H
Natural or LP (Propane) Gas Electronic Modulating — Duct Stat4, 5 J
Electronic Modulating w/External L
4-20 mA Input
Electronic Modulating w/External N
0-10 VDC Input
Separated Intermittent Pilot — Single-Stage D
Combustion Units Natural or LP (Propane) Two-Stage E
Intermittent Pilot — Electronic Modulating — Room Stat4 H
Natural or LP (Propane) Gas Electronic Modulating — Duct Stat4, 5 J
Electronic Modulating w/External L
4-20 mA Input
Electronic Modulating w/External N
0-10 VDC Input
Tubular Heat Exchanger Units Hot surface pilot ignition Single-Stage K
Tubular Heat Exchanger Units Hot surface pilot ignition Two-Stage E
Notes:
1. Specify discharge temperature in the body of the order. Two hydraulic modulating valves are offered. One valve has a range of 60-100 degrees. The other valve has a range of
75-200°. If no temperature is specified, the 60-100 range will ship. N/A on sizes 003-007.
2. For elevations over 4000 ft., hydraulic modulating is not available.
3. Units for California shipment require intermittent pilot ignition.
4. Not available on sizes 003-007. These sizes are AGA approved on single stage gas controls only. Two-stage control is available up to 7,500 ft. elevation. Over 7500 ft., single
stage only.
5. Only available on duct unit heaters or centrifugal with duct discharge flange option.
** Not available.
Contact Macon Product Support for more
The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-9 Effective 1/1/06
Indoor Gas Heating Products
Indoor Unit Options
(Factory Installed)
Table PTAC/UH-10-A — Miscellaneous Options
Available On Option Designator
All Gas Special Orifices B**
Heating Units3 Summer-Winter Switch* D
Centrifugal Fan Unit Heaters Duct Discharge Flange1 H**
Indoor Duct FanTime Delay Control L
Furnaces Side Access Burner Drawer2 K
Horiz. Blower Assembly Motor 3 See Table PTAC/UH-9-A
Notes:
* When used with a duct furnace, optional fan time delay control must be ordered.
1. Not required when nozzles are ordered.
2. Standard side access is on the left side as the airflow is blowing in your face. Opposite from standard can be ordered as a special. Contact Macon Product Support.
3. Not available on Tubular Heat Exchanger units.
** Not available.

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-10 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Indoor Unit Accessories
(Factory Installed)
Table PTAC/UH-11-A— Miscellaneous Options
Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040
MBh
Available On Option Des 30 45 60 75 100 125 150 175 200 225 250 300 350 400
409 S.S. Burners A — — — —
All Units1 409 S.S. Flue
Collector
/Draft Diverter C — — — —
Vertical Louvers E — — — —
Horiz. Louvers F — — — —
Indoor Horiz. & Vertical
Duct Furnaces Louvers G — — — —
Unit Size 32 42 62 94
Horiz. Blower Insul. for Blower
Assembly &Transition 1
Available on Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040
Propeller Fan, MBh
High Efficiency Option Des 30 45 60 75 100 125 150 175 200 225 250 300 350 400
Propeller Fan OSHA Fan Guards 7
and Tubular
Heat Exchanger
Separated OSHA Fan Guards 7 — — — —
Combustion
Propeller Fan Units
Note:
1. 409 S.S. Burners, 409 S.S. Flue Collector/Draft Diverter and Vertical Louvers are not available on Tubular Heat exchanger units.

Contact Macon Product Support for more


The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-11 Effective 1/1/06
Indoor Gas Heating Products
Indoor Unit Accessories
(Field Installed)
Table PTAC/UH-12-A—Flue Vent Fans
Flue Vent Fan Thermostat4 Unit 003 004 006 007 010 012 015 017 020 022 025 030 035 040
Power Supply Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400
115/60/1 Ordering No
Low 350-0019- 01 02 04 05 06 07 08 09 10 11 12 13 14 15
1
List Price
208/60/1 Order No
Low 350-0019- — — — 17 18 19 20 21 22 23 24 25 26 27
2
List Price
230/60/1 Order No
Low 350-0019- — — — 29 30 31 32 33 34 35 36 37 38 39
3
List Price
Notes:
All flue vent fans provided with adaptor for unit mounting.
1. For use with units with 115/60/1 main power supply.
2. For use with units with 208/60/1 or 208/60/3 main power supply.
3. For use with units with 230/60/1, 230/60/3, 460/60/3, or 575/60/3 main power supply. Order should specify when for use with units with 460/60/3 or 575/60/3 main power supply, a
460/230V transformer is required.
4. Flue vent fans for use with low voltage thermostats are provided with a relay with 24V holding coil.
5. Flue vent fans are standard 115V on GHPD, GHND, GBPD, GBND, GLND, GLPD, GAND, GAPD, GKND, GKPD, GMND, GMPD, GTND,GTPD units and included in the unit. Do not
order separately.

Table PTAC/UH-12-B—Miscellaneous Accessories


Available On Option Pipe Size Order No 350-
Natural Gas High Gas Line
Heating Units Pressure Regulator (See Note) 3/4” NPT 0015-20
Notes:
When high gas line pressure regulators are ordered you must specify the pressure at the job. This is required so the factory can select the regulator to accommodate the
specific pressure at the job. More than one unit can be run from one regulator, however, we recommend that each unit have its own regulator. See orifice chart that
follows. N/A requires local purchase of regulator.
When ordered separate, must include model and size of unit.

Orifice Chart: Rockwell 043-182 Regulator


Inlet Capacity in MBh for Natural Gas Spring
Pressure 25-200 225-300 350-500 600 700 800 Required
1 psi 3/8” — — — — — Blue (only)
2 3/8” 3/8” — — — — Blue (only)
3 3/8” 3/8” 3/8” — — — Blue or Green
5 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Blue or Green
10 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” Blue or Green
20 1/4” 1/4” 1/4” 1/4” 1/4” 5/16” Blue or Green
40 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” Blue or Green
60 1/8” 1/8” 1/8” 1/8” 1/8” 3/16” Blue or Green
80 1/8” 1/8” 1/8” 1/8” 1/8” — Blue or Green
100 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” Blue or Green
125 1/8” 1/8” 1/8” 1/8” 1/8” 1/8” Blue or Green

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-12 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Indoor Unit Accessories
(Factory Installed)
Table PTAC/UH-13-A—Miscellaneous Accessories
Unit Size 010 012 015 017 020 022 025 030 035 040
Available On Option Unit MBh 100 125 150 175 200 225 250 300 350 400
All Units 6 Y Splitter Ordering No
Discharge 350-0018- 03 04 05 06 07 08 09 10 11 12
Nozzle1 List Price
90° Downward Ordering No
Discharge 350-0018- 27 28 29 30 31 32 33 34 35 36
Nozzle1,4 List Price
30° Downward Ordering No
Discharge 350-0018 65 45 46 47 48 49 50 51 52 53
Nozzle 1,4 List Price
60° Downward Ordering No
Discharge 350-0018 68 54 55 56 57 58 59 60 61 62
Nozzle 1,4 List Price
Ordering No
Only Drain Pan5 350-0076- 03 04 05 06 07 08 09 10 11 12
Indoor (Al Steel) List Price
Duct Furnaces, & Ordering No
Hi Eff. Drain Pan5 350-0076- 15 16 17 18 19 20 21 22 23 24
not Sep. Comb. (409 SS) List Price
Unit Size 15 20 30 45
Horiz. Blower Ordering No
Assembly 1”TA Filter 350-0050- 01 01 03 05
Set List Price
1” Perm Filter Ordering No
Set 350-0050- 02 02 04 06
(Std on HBAC) List Price
Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040
Option Unit MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400
Available on OSHA Ordering No
Propeller Fan, Fan 350-0154- 01 01 02 02 02 02 02 04 04 04 04 03 05 05
High Efficiency Guards List Price
Propeller Fan and
Tubular Heat
Exchanger Units
Separated OSHA Ordering No.
Combustion Fan 350-0154- — — — — 02 02 02 04 04 04 04 03 05 05
Propeller Fan Units Guards List Price
Notes:
1. Available on all indoor units 100-400 MBh.
2. Only available on Duct Furnaces and Centrifugal Fan Unit Heaters.
3. When nozzles are ordered separate from the unit, specify unit type. High efficiency units have different nozzle configurations than standard units.
4. 60° nozzles are two 30° and 90° nozzles are three 30° nozzles. All nozzles ship unassembled.
5. Recommended when used downstream of a cooling coil.
6. If unit has (E) vertical louvers and nozzles are ordered, vertical louvers not needed because vertical louvers are on nozzles.

Contact Macon Product Support for more


The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-13 Effective 1/1/06
Indoor Gas Heating Products
Indoor Unit Accessories
(Field Installed)
Table PTAC/UH-14-A— Vent Caps and Adapters (Reducers or Increasers)
Unit Size 003 004 006 007 010 012 015 017 020 022 025 030 035 040
Available on all Option Unit MBh 30 45 60 75 100 125 150 175 200 225 250 300 350 400
High Efficiency and 4” Ordering No
Separated Vent Cap 0350-0155- 01 01 01 01 01 01 01 01 — — — — — —
Combustion Units
andTubular Heat 5” Ordering No
Exchanger Units Vent Cap 0350-0157- — — — — — — — — 01 01 01 — — —

6” Ordering No
Vent Cap 0350-0158- — — — — — — — — — — — 01 01 01

5” to 4” Ordering No
Reducer 0350-0156- 01 01 01 01 01 01 01 01 — — — — — —

5 to 6” Ordering No
Increaser 0350-0159- — — — — — — — — — — — 01 01 01

Notes:
1. These are mandatory, for the Canadian market, per the National Standard of Canada section B149, 1M91 for category 3 venting: (III). Use Certified venting system provided
by (Manufacturer).
2. Tubular heat exchanger units do not require reducers or increasers.

Table PTAC/UH-14-B— Thermostats


Type Voltage Range Order No 350-
Single Stage Room Low (24V) 55 - 95°F 0015-01
Duct Low (24V) 55 - 175°F 0015-07
Single Stage* Room with Summer Winter Switch2 Low (24V) 55 - 95°F 0015-02
Room with Summer Winter Switch2 Low (24V) 45 - 85°F 0015-03
Two Stage Duct Low (24V) 55 - 175°F 0015-08
Electronic Room Low (24V) 60 - 85°F Included in Gas
Modulating Duct Low (24V) 65 - 85°F Control Option Price
Override Room (for use with duct) Line 115V 50 - 90°F 0015-05
Universal Guard for RoomThermostats 0015-06
Notes:
*When used with a duct furnace, optional fan time delay control must be ordered.
1. Two-stage room thermostat with Fan Auto-On Switch and System Off-Auto Switch.
2. Summer/winter switch does not lock out the heat.
3. The only Thermostats available for Tubular heat exchanger units are Single Stage Room, Order No. 0350-0015-01 and Single Stage Room W/Summer Winter Switch, Order
No. 0350-0015-02.

Table PTAC/UH-14-C— Concentric Vent Terminals


Available On Option Ordering No.
Separated Combustion Vertical Concentric Vent Kit1 0350-0151-01
Units ONLY Horizontal Concentric Vent Kit2 0350-0152-01
Notes:
1. Kit includes 5” cap with special attached nonrecirculation disc, special 8” cap with 5” hole and concentric vent box.
2. Kit includes 5” cap with special attached nonrecirculation disc, inlet air screen and concentric vent box.

Table PTAC/UH-14-D— Vertical Louver Kits (Propeller and Centrifugal Fan Unit Heaters Only)
GPND
030 004 006 007 010 012 015 017 020 022 025 030 035 040
Ordering No. Contact Macon Product Support
Quantity Required for Ordering Information

Notes:
1. Kits are for use in modifying existing units in the field. Kits for GPND-003 thru 007 are complete assemblies including frame and louvers. Kits for all other units include
individual louver with fastening springs.
2. When ordering vertical louvers for new equipment, refer to Table PTAC/UH-11-A.
3. These Kits are not available for Tubular Heat Exchanger units.

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-14 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Indoor Unit Accessories
(Field Installed)
Table PTAC/UH-15-A— Natural to Propane Gas Conversion Packages — Single Stage
Unit Type and Size
— Converting — Ordering No.
PilotType From To 350-0119-
Standing GPND-003-A GPPD-003-A 01
Pilot1 GPND-004-A GPPD-004-A 02
GPND-006-A GPPD-006-A 04
GPND-007-A GPPD-007-A 06
GPND-010-A GPPD-010-A 07
GPND-012-A GPPD-012-A 08
GCND-012-A GCPD-012-A
GPND-015-A GPPD-015-A 09
GCND-015-A GCPD-015-A
GPND-017-A GPPD-017-A 10
GCND-017-A GCPD-017-A
GPND-020-A GPPD-020-A 11
GCND-020-A GCPD-020-A
GPND-022-A GPPD-022-A 12
GCND-022-A GCPD-022-A
GPND-025-A GPPD-025-A 13
GCND-025-A GCPD-025-A
GPND-030-A GPPD-030-A 14
GCND-030-A GCPD-030-A
GPND-035-A GPPD-035-A 15
GCND-035-A GCPD-035-A
GPND-040-A GPPD-040-A 16
GCND-040-A GCPD-040-A
GDND-010-A GDPD-010-A 35
GDND-012-A GDPD-012-A 36
GDND-015-A GDPD-015-A 37
GDND-017-A GDPD-017-A 38
GDND-020-A GDPD-020-A 39
GDND-022-A GDPD-022-A 40
GDND-025-A GDPD-025-A 41
GDND-030-A GDPD-030-A 42
GDND-035-A GDPD-035-A 43
GDND-040-A GDPD-040-A 44
Intermittent Pilot2 Not Available — Not Available
Notes:
1. Conversion packages are for use in modifying existing units in the field from Natural Gas to Propane Gas. Use only with units with Single Stage — Standing Pilot gas
controls. D Development Series Only.
2. Conversion Packages to convert from Natural Gas to Propane Gas with intermittent pilot ignition are not available.
3. When ordering conversion packages, complete Model Number and Serial Number must be included in the body of the order.
4. Control product marketing for units with development sequence prior to “D”.
5. Kit includes pilot burner, main burner orifices and a spring for the existing valve.
6. For these kits you may receive any of the numbers selected due to the fact all kits are the same:
350-0119-01, 02, 04 and 06 – all the same.
350-0119-07, 08, 09 and 10 – all the same.
350-0119-14, 15 and 16 – all the same.

Contact Macon Product Support for more


The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-15 Effective 1/1/06
Indoor Gas Heating Products
Indoor Unit Accessories
(Field Installed)
Table PTAC/UH-16-A—Propane to Natural Gas Conversion Packages— Single Stage
UnitType and Size
— Converting — Ordering No.
PilotType From To 350-0119-
Standing GPP*-003-A GPN*-003-A 17
Pilot1 GPP*-004-A GPN*-004-A 18
GPP*-006-A GPN*-006-A 20
GPP*-007-A GPN*-007-A 22
GPP*-010-A GPN*-010-A 23
GCP*-010-A GCN*-010-A
GPP*-012-A GPN*-012-A 24
GCP*-012-A GCN*-012-A
GPP*-015-A GPN*-015-A 25
GCP*-015-A GCN*-015-A
GPP*-017-A GPN*-017-A 26
GCP*-017-A GCN*-017-A
GPP*-020-A GPN*-020-A 27
GCP*-020-A GCN*-020-A
GPP*-022-A GPN*-022-A 28
GCP*-022-A GCN*-022-A
GPP*-025-A GPN*-025-A 29
GCP*-025-A GCN*-025-A
GPP*-030-A GPN*-030-A 30
GCP*-030-A GCN*-030-A
GPP*-035-A GPN*-035-A 31
GCP*-035-A GCN*-035-A
GPP*-040-A GPN*-040-A 32
GCP*-040-A GCN*-040-A
GDP*-010-A GDN*-010-A 47
GDP*-012-A GDN*-012-A 48
GDP*-015-A GDN*-015-A 49
GDP*-017-A GDN*-017-A 50
GDP*-020-A GDN*-020-A 51
GDP*-022-A GDN*-022-A 52
GDP*-025-A GDN*-025-A 53
GDP*-030-A GDN*-030-A 54
GDP*-035-A GDN*-035-A 55
GDP*-040-A GDN*-040-A 56
2
Intermittent Pilot All Units Contact Macon Product Support
Notes:
1. Conversion packages are for use in modifying existing units in the field from Propane Gas to Natural Gas. Use only with units with Single Stage gas controls. D Develop-
ment Series Only.
2. Conversion Packages — Intermittent Pilot Ignition, are available upon request from the parts department.
3. *When ordering conversion packages, complete Model Number and Serial Number must be included in the body of the order. Make sure that the * is replaced by the
development sequence number.
4. Kit includes pilot burner, main burner orifices and a gas valve.

Contact Macon Product Support for more


information on these products (1-800-322-6495)
The State of California requires a steady-state efficiency of 80% for
both indoor and outdoor gas heating equipment. All units shipping
Effective 1/1/06 PTAC/UH-16 to the state of California require intermittent pilot ignition.
Indoor Gas Heating Products
Indoor Unit Accessories

Table PTAC/UH-17-A—All Indoor Duct Furnaces (Std., High Effic. and Separated Combustion Units) Heat Exchanger Warranty Net
Prices Option Extended Warranty1
5 year 10 year
Unit MBh 2nd-5th year 2nd-10th year
Size input alum 409SS 321SS alum 409SS 321SS
010 100
012 125
015 150
017 175
020 200
022 225
025 250
030 300
035 350
040 400
Ordering Number 2705-4000-05-00 2705-4000-06-00
Product Code 588 588
Note:
1. The extension applies only to new equipment installed in domestic sales territories and must be ordered prior to start-up.

Table PTAC/UH-17-B—Indoor Unit Shipping Weights


UnitType 030 004 006 007 010 012 015 017 020 022 025 030 035 040
Propeller Unit Heater 70 85 100 110 165 188 210 229 240 266 296 341 405 452
High Efficiency
Propeller Unit Heater 79 94 109 119 174 197 219 238 249 275 305 350 414 461
High Efficiency
Centrifugal Unit Heater — — — — 262 279 314 336 363 408 427 471 561 594
Centrifugal Unit Heater — — — — 253 270 315 335 351 396 415 459 550 582
Duct Furnace — — — 140 152 162 180 195 216 224 272 348 360
High Efficiency
Duct Furnace — — — — 162 164 174 192 207 228 236 284 360 372
Separated Combustion
Propeller Unit Heater — — — — 200 228 256 284 312 340 368 432 488 545
Centrifugal Unit Heater — — — — 298 330 362 394 426 458 490 558 619 678
Separated Combustion — — — — 161 180 188 207 227 246 266 305 344 383
Indoor Gas Duct Furnace
Tubular Heat Exchanger 72 78 102 108 173 185 195 241 251 — 261 367 381 395
Propeller Unit Heater
Unit Size 15 20 30 45
Horiz Blower Assy (wt less Motor) 135 155 200 295

Contact Macon Product Support for more


The State of California requires a steady-state efficiency of 80% for information on these products (1-800-322-6495)
both indoor and outdoor gas heating equipment. All units shipping
to the state of California require intermittent pilot ignition. PTAC/UH-17 Effective 1/1/06
Propeller Type Unit Heaters
Model S — Horizontal Units

1. Model S Unit Heaters (Tables PTAC/UH- 3. Coils Unit heater name plates will use the 11th digit
19-A-PTAC/UH-25-E) include stock units, The standard coil is 1-row 0.031'’ wall 1'’ of the 21 digit model number system to
as well as production unit casing with O.D. copper tubing with 108 Sigma-Flo® designate the coil tube material as follows —
motor, coil, fan, fin, tube, fan guard and aluminum fins per foot and are suitable for A — STD. COPPER
horizontal louvers. service on steam to 75 psi and water at
325° at 200 psi. Coil variations are as C — RED BRASS
2. Units with modified coils (odd numbered
units) are generally not suitable for entering indicated in F — STEEL
water temperatures below 180° because of PTAC/UH-18-A.
4. Motors
low final air temperatures. See Engineering Standard cycle motors are indicated in
Bulletin EB-UH7 (photocopy only available PTAC/UH-18-B.
from Inland printing 608-783-4700 or on
EAGLE), 15-24 for capacity data.

Table PTAC/UH-18-A—S Unit Heater Coil — Temperature & Pressure Limitations


Tube Steam Hot Water
Model S Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin Material
Copper (Std.) 1'’ .031'’ 75 325 200 325
Red Brass 1'’ .049'’ 75 325 260 390 Alum. or Copper
Steel 1'’ .049” 75 325 400 450 (Std.)

Table PTAC/UH-18-B—Standard Motors for Model S Unit Heaters


Top Avail. Current Thermal Winding
hp Speed Speed Type Bearing Char. Overload Insulation
1/50 1075 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’
Shaded Pole
1/20 1550 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’
Shaded Pole
1/8 1550 Variable* TE-TOP Sleeve 115/60/1 Yes ‘’B’’
Perm. Split Cap.
1/6-1/4-1/2 1100 1 TE-TOP Ball 115/60/1 Yes ‘’B’’
Perm. Split Cap.
1/6-1/4-1/2 1140 1 3-Phase Ball 208/230/460/60/3 No ‘’B’’
3/4 1140 1 3-Phase Ball 208/230/460/60/3 No “B”
1/6-1/4-1/2 1140 1 Exp. Proof Ball 115/60/1 Yes “B”
Class I, Group D 208/230/460/60/3 Yes “B”
3/4 1145 1 Class II, Group F & G Ball 208/230/460/60/3 Yes “B”
Divisions I And II
NOTES:
1. Special motors (575/60/3) may be ordered by using appropriate designators in the 13th and 14th digits of the model number. Contact St. Louis (888-872-6302) for availability.
2. Unit sizes 18S thru 100S with 115/60/1 motors can be operated at variable speeds with the addition of solid-state speed control from Table PTAC/UH-25-B.
3. TE = Totally enclosed.
4. TOP = Thermal overload protection.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-18 information.
Propeller Type Unit Heaters
Model S — Constant Speed

Table PTAC/UH-19-A—Packed Stock Horizontal Model S Unit Heaters Constant Speed


Capacities
Louver Fin Steam @2# and Hot Water @200° EWT
Diffuser 60° EAT 60° EAT and 20° WTD
Unit Unit Order No. Unit
Model Order Digit 17 Ship cfm Final Model
No. No. B hp rpm wt. # @ 70 Mbh Temp. Mbh gpm No.
UHSA- 0136- Model S Horizontal Units — Standard Full Coil
18S 0101-01 4601-3049-01 1/50 1075 38 280 17.4 117 3.5 .36 18S
20S-2 0102-01 4601-3049-01 1/50 1075 40 318 20.0 118 6.4 .66 20S-2
38S 0103-01 4601-3049-01 1/20 1550 42 544 38.7 126 19.1 1.97 38S
42S 0104-01 4601-3049-01 1/20 1550 42 590 41.6 125 20.0 2.06 42S
60S 0105-01 4601-3049-02 1/20 1550 57 815 60.5 129 34.6 3.56 60S
70S 0106-01 4601-3049-02 1/8 1550 61 1100 68.2 117 40.4 4.17 70S
90S 0107-01 4601-3049-03 1/8 1550 73 1214 87.6 127 55.7 5.74 90S
100S 0108-01 4601-3049-03 1/8 1550 84 1535 96.0 118 62.5 6.44 100S
126S 0109-01 4601-3049-04 1/6 1100 102 1760 125.7 126 84.9 8.74 126S
168S 0110-01 4601-3049-05 1/6 1100 145 2380 172.0 127 115.3 11.88 168S
186S 0111-01 4601-3049-05 1/4 1100 147 2808 185.2 121 125.4 12.92 186S
230S 0112-01 4601-3049-06 1/4 1100 190 3300 229.7 124 161.7 16.67 230S
260S 0113-01 4601-3049-06 1/2 1100 195 4100 256.3 118 181.1 18.67 260S
320S 0114-01 4601-3049-07 1/2 1100 245 4480 324.0 127 234.3 24.15 320S
354S 0115-01 4601-3049-07 1/2 1100 250 5660 355.5 118 264.9 27.30 354S
Notes:
1. All units on this page are carried in stock (limited quantities) for immediate shipment.
2. All stock units have single phase motors.
3. Unit sizes 18S thru 100S with 115/60/1 std. motors can be operated at variable speeds with addition of solid-state speed control from Table PTAC/UH-25-B.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-19 Effective 1/1/06
Propeller Type Unit Heaters
Model S Unit and Motor Selections

Table PTAC/UH-20-A—Model S Unit and Motor Selections


Unit Motor Motor
Size hp rpm Voltage Type 13th Digit / 14th Digit
018 1/50 1075 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
019 1/50 1075 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
020 1/50 1075 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
031 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
038 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
042 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
045 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
053 1/8 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
060 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-20 information.
Propeller Type Unit Heaters
Model S Unit and Motor Selections

Table PTAC/UH-21-A—Model S Unit and Motor Selections (Continued)


Unit Motor Motor
Size HP RPM Voltage Type 13th Digit / 14th Digit
069 1/8 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
070 1/8 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
077 1/8 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
090 1/8 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
091 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
100 1/8 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
126 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
127 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
137 1/4 1100 115/60/1 TE 1/T
1/4 1140 208/230/460/60/3 TE (2,3,4)/T
1/4 1140 115/60/1 X-Proof 1/E
1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
168 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-21 Effective 1/1/06
Propeller Type Unit Heaters
Model S Unit and Motor Selections

Table PTAC/UH-22-A—Model S Unit and Motor Selections (Continued)


Unit Motor
Size HP RPM Voltage Type Digit 13 / Digit 14
181 1/4 1100 115/60/1 TE 1/T
1/4 1140 208/230/460/60/3 TE (2,3,4)/T
1/4 1140 115/60/1 X-Proof 1/E
1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
186 1/4 1100 115/60/1 TE 1/T
1/4 1140 208/230/460/60/3 TE (2,3,4)/T
1/4 1140 115/60/1 X-Proof 1/E
1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
207 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
230 1/4 1100 115/60/1 TE 1/T
1/4 1140 208/230/460/60/3 TE (2,3,4)/T
1/4 1140 115/60/1 X-Proof 1/E
1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
243 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
260 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
273 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
320 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
354 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
400 3/4 1140 208/230/460/60/3 TE (2,3,4)/T
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
3/4 1140 575/60/3 Totally Enclosed 5/T
Units in bold print can also be ordered from packed stock. See Table PTAC/UH-19-A for stock ordering number.
Notes:
1. Units with modified coils (odd numbered units; 019, 031, etc.) are used in applications with lower final temperatures. These units not available as packed stock.
2. All single-phase motors have built-in overload protection.
3. 115/60/1, TE motors on unit sizes 18S-90S and 100S can be operated at variable speeds with the addition of a solid-state speed control. See Table PTAC/UH-25-B for selection.
4. All explosion-proof motors meet Class I, Group D; Class II, Group F and G; Divisions 1 and 2.
5. Verify electrical characteristics of motors are ordered correctly.
6. Special motor requirements are available. Contact St. Louis (888-872-6302) for availability.
7. TE = Totally Enclosed
8. X-Proof = Explosion Proof

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-22 information.
Propeller Type Unit Heaters
Model S Coil and Fin

TTable PTAC/UH-23-A—Model S Coil Type Table PTAC/UH-23-B—Model S Fin Series


Unit Size Designator Unit Size Designator
018 S 018 8
W 2
019* S 019 8
W 2
020 S 020 8
W 2
031* S 031 8
W 2
038 S 038 8
W 2
042 S 042 8
W 2
045* S 045 8
W 2
053* S 053 8
W 2
060 S 060 8
W 2
069* S 069 8
W 2
070 S 070 8
W 2
077* S 077 8
W 2
090 S 090 8
W 2
091* S 091 8
W 2
100 S 100 8
W 2
126 S 126 8
W 2
127* S 127 8
W 2
137* S 137 8
W 2
168 S 168 8
W 2
181* S 181 8
W 2
186 S 186 8
W 2
207* S 207 8
W 2
230 S 230 8
W 2
243* S 243 8
W 2
260 S 260 8
W 2
273* S 273 8
W 2
320 S 320 8
W 2
354 S 354 8
W 2
400 S 400 8
W 2
*Units have modified coil for lower outlet temperatures. Notes:
Notes: 1. Std = Standard
1. Std = Standard 2. N/C = No Charge
2. Type “S” coils can be operated with either steam or hot water. 3. Selection of digit “8” equals 108 fins per foot.
3. Type “W” coils are for use with hot water only and have turbulators. 4. Selection of digit “2” equals 132 fins per foot.
5. 132 fins per foot is standard on models 020, 019 and 400.
Contact Waco Product Support for more
These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-23 Effective 1/1/06
Propeller Type Unit Heaters
Model S Tube Material

Table PTAC/UH-24-A—Model S Tube Material Table PTAC/UH-24-B—(Continued) Model S Tube Material


Unit Size Type Designator Unit Size Type Designator
018 Copper A 126 Copper A
Red Brass C Red Brass C
Steel F Steel F
019 Copper A 127 Copper A
Red Brass C Red Brass C
Steel F Steel F
020 Copper A 137 Copper A
Red Brass C Red Brass C
Steel F Steel F
031 Copper A 168 Copper A
Red Brass C Red Brass C
Steel F Steel F
038 Copper A 181 Copper A
Red Brass C Red Brass C
Steel F Steel F
042 Copper A 186 Copper A
Red Brass C Red Brass C
Steel F Steel F
045 Copper A 207 Copper A
Red Brass C Red Brass C
Steel F Steel F
053 Copper A 230 Copper A
Red Brass C Red Brass C
Steel F Steel F
060 Copper A 243 Copper A
Red Brass C Red Brass C
Steel F Steel F
069 Copper A 260 Copper A
Red Brass C Red Brass C
Steel F Steel F
070 Copper A 273 Copper A
Red Brass C Red Brass C
Steel F Steel F
077 Copper A 320 Copper A
Red Brass C Red Brass C
Steel F Steel F
090 Copper A 354 Copper A
Red Brass C Red Brass C
Steel F Steel F
091 Copper A 400 Copper A
Red Brass C Red Brass C
Steel F Steel F
100 Copper A Note:
Red Brass C 1. Std = Standard
Steel F 2. Tube temperature and pressure limitations found in Table PTAC/UH-18-A.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-24 information.
Propeller Type Unit Heaters
Model S Accessories and Coatings
Table PTAC/UH-25-A—Model S Louver Fin Diffuser Table PTAC/UH-25-D—Model S OSHA Wire Guards
Unit Size Ordering Number Digit 17 (Standard Units Only)
018 4601-3049-01 B Unit Size Ordering Number
019 4601-3049-01 B 018 0136-0251-01
020 4601-3049-01 B 019 0136-0251-02
031 4601-3049-01 B 020 0136-0251-03
038 4601-3049-01 B 031 0136-0251-04
042 4601-3049-01 B 038 0136-0251-05
045 4601-3049-02 B 042 0136-0251-06
053 4601-3049-02 B 045 0136-0252-01
060 4601-3049-02 B 053 0136-0252-03
069 4601-3049-03 B 060 0136-0252-02
070 4601-3049-02 B 069 0136-0252-05
077 4601-3049-03 B 070 0136-0252-04
090 4601-3049-03 B 077 0136-0253-01
091 4601-3049-04 B 090 0136-0252-06
100 4601-3049-03 B 091 0136-0253-02
126 4601-3049-04 B 100 0136-0253-03
127 4601-3049-05 B 126 0136-0253-04
137 4601-3049-05 B 127 0136-0254-03
168 4601-3049-05 B 137 0136-0254-04
181 4601-3049-06 B 168 0136-0254-01
186 4601-3049-05 B 181 0136-0254-05
207 4601-3049-06 B 186 0136-0254-02
230 4601-3049-06 B 207 0136-0255-01
243 4601-3049-07 B 230 0136-0254-06
260 4601-3049-06 B 243 0136-0255-02
273 4601-3049-07 B 260 0136-0255-03
320 4601-3049-07 B 273 0136-0255-04
354 4601-3049-07 B 320 0136-0255-05
400 4601-3049-07 B 354 0136-0255-06
Notes:
Table PTAC/UH-25-B—Model S & P Starter and Control 1. OSHA guards will be factory installed when ordered with a corresponding standard unit
Accessories heater.
2. Field installation of “type 2” motor mounts (three-phase and explosion-proof motors)
Ordering Model requires cutting portions of the guard to fit over motor side arm. Guards are not OSHA.
Number Number Description 3. To order OSHA guards for standard unit, digit 15 must be A.
X13011500 600TAX 4 Manual Starter without 1
overload protection Table PTAC/UH-25-E—Special Coatings for Model S Unit Heaters
X13510361-01 T451A Light-Duty Thermostat 2 Epoxy Baked
X13530027-01 Q473B Light-Duty Subbase 3 Unit Size Epoxy Phenolic Phenolic
X13080500 T6051A Heavy-DutyThermostat 4 18,19,20,31,38,42,45,53
X13530028-01 Q651A Heavy-Duty Subbase 5 60,69,70,77,90,91
136-0162-01 KBWC-15 Solid-State Speed Control 6 100,126,127,137
168,181,186,207,230
Table PTAC/UH-25-C— Model S & P Starter and 243,260,273,320
Control Accessories (Continued) 354,400
Digit Designator Digit 17/D: Any Coating on All Louver Fin Diffusers =
18 A Notes:
20 B 1. Surface preparation: sandblasting, except coils which are chemically cleaned. Inside and
outside of each casing, fan blade and heating coil are special coated. Motors cannot be
21 E special coated.
20 C 2. Epoxy Coating (Digit 16/R) : Two coats on all subassemblies and one coat on assembled.
21 F Unit force cured at 150° F.
3. Epoxy Phenolic Coating (Digit 16/T)
16/T): Two coats on all subassemblies and one coat on
19 D assembled. Unit force cured at 150°F.
Notes: 4. Baked Phenolic Coating (Digit 16/W)
16/W): Four coats on all surfaces. Baked at 325°F on
1. NEMA Type 1, single-pole, single-throw, one hp, 110 220V, toggle operated. For intermediate coats and 425°F on cure.
use on single-phase operation only. 5. To order, enter appropriate designator in digit 16.
2. Line voltage 8.0 Amps, 56°-94° range. 6. All units reshipped in original cartons.
3. Auto-off. For use with light duty thermostat.
4. Line voltage 16.0 Amps, 45°-85° range.
5. Auto-off-on for use with heavy-duty thermostat.
6. 120V, five Amps. (Only available up to 100S).

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-25 Effective 1/1/06
Propeller Type Unit Heaters
Model P — Vertical Units

1. Model P Unit Heaters (Tables PTAC/UH- 4. Unit heater name plates will use the 11th
27-A-PTAC/UH-30-A) include stock units, digit of the 21 digit model number system
as well as production unit casing with to designate the coil tube material as
motor, coil, fin, tube, fan guard and fan. follows:
A — STD. COPPER
2. Model PL Unit Heaters are identical to
Model P. The performance difference is a C — RED BRASS
F — STEEL
result of removing the air ports in the field.
3. Coils 5. Motors
Standard cycle motors are described in
The standard coil 1-row 0.025'’ wall 5/8'’
O.D. copper with 144 Sigma-Flo® aluminum Table PTAC/UH-26-B.
fins per foot and threaded steel pipe Special motors may be ordered.
(575/60/3) by putting appropriate
headers. Coils are suitable for service on
75 psi steam or water at 325 F at 225 psi. designators in Digits 13 and 14 of model
Coil variations are as indicated in Table number. Contact St. Louis (888-872-6302)
PTAC/UH-26-A.

Table PTAC/UH-26-A—Type ‘’P’’ Unit Heater Coil — Temperature & Pressure Limitations
Tube Steam Hot Water
Model P Material O.D. Wall Pres.-PSIG Deg.°F Pres.-PSIG Deg.°F Fin Material
Copper (Std.) 5/8'’ .025'’ 75 325 225 325
Red Brass 5/8'’ .049'’ 75 325 300 425 Alum. or Copper
Steel 5/8'’ .049'’ 75 325 400 450 (Std.)

Table PTAC/UH-26-B—Standard Motors for Model P Unit Heaters


Top Avail. Current Thermal Winding
hp Speed Speed Type Bearing Char. Overload Insulation
1/40-1/20 1550 Variable TE-TOP Sleeve 115/60/1 Yes ‘’B’’
Shaded Pole
1/8 1070 Variable TE-TOP PSC Sleeve 115/60/1 Yes ‘’B’’
1/6-1/4-1/2 1100 1 TE-TOP Ball 115/60/1 Yes ‘’B’’
Perm. Split Cap.
1/6-1/4-1/2 1140 1 3-Phase Ball 208/230/460/60/3 No ‘’B’’
3/4 1140 1 TE Polyphase Ball 208/230/460/60/3 No ‘’B’’
1½ 1160 1 TE Polyphase Ball 208/230/460/60/3 No “B”
3 1165 1 TE Polyphase Ball 208/230/460/60/3 No “B”
1/6-1/4-1/2 1140 1 Exp. Proof Ball 115/60/1 Yes “B”
3 1150 1 Class I, Group D Ball 208/230/460/60/3 Yes “B”
3/4 1145 1 Class II, Group F & G Ball 230/460/60/3 Yes “B”
Divisions I and II
1½ 1150 1 Ball 230/460/60/3 Yes “B”
1. Special motors (575/60/3) may be ordered by using appropriate designators in digits 13 and 14 of model number. Contact St. Louis
(888-872-6302) for availability.
2. Unit sizes 42P thru 102P may be operated as variable speeds with addition of solid-state control from Table PTAC/UH-29-C.
3. TE = Totally Enclosed
4. TOP = Thermal Overload Protection
5. PSC = Permanent Split Capacitor.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-26 information.
Propeller Type Unit Heaters
Model P — Constant Speed and
Motor Selections
Table PTAC/UH-27-A—Packed Stock Vertical Model P Unit Heaters Constant Speed
Capacities
Steam @2# and Hot Water @200° EWT
Louver (Digit 17/A) 60° EAT 60° EAT and 20° WTD
Unit Unit Cone Unit
Model Order Diffuser Ship cfm Final Model
No. No. Order No. hp rpm wt. # @ 70 Mbh Temp. Mbh gpm No.
UHPA- 136- Model P (Standard Vertical Units)
42P* 0143-01 4607-330-01 1/40 1550 28 595 41.3 124 22.7 2.34 42P
64P* 0144-01 4607-330-02 1/20 1550 37 989 65.5 121 39.6 4.08 64P
80P* 0145-01 4607-330-02 1/20 1550 41 1200 80.6 122 48.4 4.99 80P
102P* 0146-01 4607-330-03 1/8 1070 57 1490 101.8 123 68.3 7.03 102P
122P 0147-01 4607-330-03 1/6 1100 57 1790 124.4 124 83.7 8.63 122P
146P 0148-01 4607-330-04 1/6 1100 80 2220 152.0 123 105.2 10.84 146P
166P 0149-01 4607-330-04 1/6 1100 82 2620 173.0 121 118.6 12.22 166P
202P 0150-01 4607-330-04 1/4 1100 86 3200 201.2 118 139.7 14.40 202P
252P 0151-01 4607-330-05 1/4 1100 134 4180 249.8 115 180.1 18.56 252P
280P 0152-01 4607-330-05 1/2 1100 134 4430 283.8 119 205.4 21.17 280P
336P 0153-01 4607-330-05 3/4 1140 144 5210 333.4 119 242.9 25.03 336P

UHPA- 136- P-L (Standard Model P with all Air-Ports Opened)


42P* 0143-01 4607-330-01 1/40 1550 28 668 34.8 108 18.9 1.95 42P
64P* 0144-01 4607-330-02 1/20 1550 37 1200 57.2 104 34.2 3.53 64P
80P* 0145-01 4607-330-02 1/20 1550 41 1360 68.0 106 40.5 4.17 80P
102P* 0146-01 4607-330-03 1/8 1070 57 1640 85.4 108 56.5 5.82 102P
122P 0147-01 4607-330-03 1/6 1100 57 2180 111.0 107 73.9 7.62 122P
146P 0148-01 4607-330-04 1/6 1100 80 2360 125.8 109 85.5 8.81 146P
166P 0149-01 4607-330-04 1/6 1100 82 2920 149.0 107 100.7 10.38 166P
202P 0150-01 4607-330-04 1/4 1100 86 3390 176.8 108 121.5 12.52 202P
252P 0151-01 4607-330-05 1/4 1100 134 4500 214.9 104 153.8 15.85 252P
280P 0152-01 4607-330-05 1/2 1100 134 5040 251.8 106 180.1 18.56 280P
336P 0153-01 4607-330-05 3/4 1140 144 5700 291.0 107 210.6 21.70 336P
*These units may be operated as variable speed with the addition of the solid-state control from Table PTAC/UH-29-C.
Notes:
1. All stock units have single phase motors except the 336P which has three-phase.
2. All units on this page are available from stock for immediate shipment. Contact St. Louis (888-872-6302) for availability.
3. Be sure the electrical characteristics of motors ordered are correct.

Table PTAC/UH-27-B—Model P Unit and Motor Selections


Unit Motor Motor
Size hp rpm Voltage Type 13th Digit / 14th Digit
042 1/40 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
064 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
080 1/20 1550 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
102 1/8 1070 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
122 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-27 Effective 1/1/06
Propeller Type Unit Heaters
Model P — Motor Selections

Table PTAC/UH-28-A— Model P Unit and Motor Selections (Continued)


Unit Motor Motor
Size hp rpm Voltage Type 13th Digit / 14th Digit
146 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
166 1/6 1100 115/60/1 TE 1/T
1/6 1140 208/230/460/60/3 TE (2,3,4)/T
1/6 1140 115/60/1 X-Proof 1/E
1/6 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
202 1/4 1100 115/60/1 TE 1/T
1/4 1140 208/230/460/60/3 TE (2,3,4)/T
1/4 1140 115/60/1 X-Proof 1/E
1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
252 1/4 1100 115/60/1 TE 1/T
1/4 1140 208/230/460/60/3 TE (2,3,4)/T
1/4 1140 115/60/1 X-Proof 1/E
1/4 1140 208/230/460/60/3 X-Proof (2,3,4)/E
1/3 1140 575/60/3 Totally Enclosed 5/T
280 1/2 1100 115/60/1 TE 1/T
1/2 1140 208/230/460/60/3 TE (2,3,4)/T
1/2 1140 115/60/1 X-Proof 1/E
1/2 1140 230/460/60/3 X-Proof (3,4)/E
1/2 1140 575/60/3 Totally Enclosed 5/T
336 3/4 1140 208/230/460/60/3 TE (2,3,4)/T
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
3/4 1140 575/60/3 Totally Enclosed 5/T
384 3/4 1140 208/230/460/60/3 TE (2,3,4)/T
3/4 1145 208/230/460/60/3 X-Proof (2,3,4)/E
3/4 1140 575/60/3 Totally Enclosed 5/T
500 1-½ 1160 208/230/460/60/3 TE (2,3,4)/T
1-½ 1150 230/460/60/3 X-Proof (3,4)/E
1-½ 1160 575/60/3 Totally Enclosed 5/T
600 1-½ 1160 208/230/460/60/3 TE (2,3,4)/T
1-½ 1150 230/460/60/3 X-Proof (3,4)/E
1-½ 1160 575/60/3 Totally Enclosed 5/T
720 3 1165 208/230/460/60/3 TE (2,3,4)/T
3 1150 230/460/60/3 X-Proof (3,4)/E
3 1165 575/60/3 Totally Enclosed 5/T
Units in bold print can be ordered from packed stock. See Table PTAC/UH-27-A for ordering information.
Notes:
1. All single-phase motors have built-in overload protection.
2. All explosion-proof motors meet Class I, Group D; Class II, Group F and G; Divisions 1 and 2.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-28 information.
Propeller Type Unit Heaters
Model P — Accessories

Table PTAC/UH-29-A—Model P Tube Material Table PTAC/UH-29-B—Model P Louver Cone Diffuser


Unit Size Type Designator Unit Size Designator Digit 17
042 Copper A 042 4607-0330-01 A
Red Brass C 064 4607-0330-02 A
Steel F 080 4607-0330-02 A
064 Copper A 102 4607-0330-03 A
Red Brass C 122 4607-0330-03 A
Steel F 146 4607-0330-04 A
166 4607-0330-04 A
080 Copper A
202 4607-0330-04 A
Red Brass C 252 4607-0330-05 A
Steel F 280 4607-0330-05 A
102 Copper A 336 4607-0330-05 A
Red Brass C 384 4607-0330-05 A
Steel F 500 4607-0330-06 A
122 Copper A 600 4607-0330-06 A
Red Brass C 720 4607-0330-06 A
Steel F
146 Copper A Table PTAC/UH-29-C—Model S & P Starter and Control
Red Brass C Accessories
Steel F Ordering Model
166 Copper A Number Number Description
Red Brass C X13011500 600TAX 4 Manual Starter without1
Steel F overload protection
202 Copper A X13510361-01 T451A A Light-DutyThermostat2
Red Brass C X13530027-01 Q473B Light-Duty Subbase3
Steel F X13080500 T6051A Heavy-DutyThermostat4
252 Copper A X13530028-01 Q651A Heavy-Duty Subbase5
Red Brass C 136-0162-01 KBWC-15 Solid-State Speed Control6
Steel F
280 Copper A Table PTAC/UH-29-D— Model S & P Starter and
Red Brass C Control Accessories (Continued)
Steel F Digit Designator
336 Copper A 18 A
Red Brass C 20 B
Steel F 21 E
384 Copper A 20 C
Red Brass C 21 F
Steel F 19 D
500 Copper A Notes:
1. NEMA Type 1, single-pole, single-throw, one hp, 110-220V toggle operated. For
Red Brass C use on single-phase operation only.
Steel F 2. Line voltage 8.0 Amps, 56°-94° range.
3. Auto-off. For use with light duty thermostat.
600 Copper A 4. Line voltage 16.0 Amps, 45°-85° range.
Red Brass C 5. Auto-off-on for use with heavy-duty thermostat.
6. 120V, Five Amps.
Steel F
720 Copper A Table PTAC/UH-29-E—Model P OSHA Wire Guards
Red Brass C
Steel F Unit Size Designator Digit 15
042 0136-0256-01 A
Notes: 064 0136-0257-01 A
1. Std = Standard
2. Tube temperature and pressure limitations found in Table PTAC/UH-26-A.
080 0136-0257-02 A
102 0136-0258-01 A
122 0136-0258-02 A
146 0136-0259-01 A
166 0136-0259-02 A
202 0136-0259-03 A
252 0136-0260-01 A
280 0136-0260-02 A
336 0136-0260-03 A
384 0136-0260-04 A
500 0136-0261-01 A
600 0136-0261-02 A
720 0136-0261-03 A
Notes:
1. OSHA guards will be factory installed when ordered with a corresponding unit
heater.
2. For the 3-phase and explosion-proof motor, the OSHA guard ships separately.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-29 Effective 1/1/06
Propeller Type Unit Heaters
Model P Coatings
Model S and P Order Numbers and
Equivalent Production Numbers
Table PTAC/UH-30-A— Special Coatings for Model P Unit Heaters
Epoxy Baked
Unit Size Epoxy Phenolic Phenolic
042, 064, 080
102, 122
146, 166, 202
252, 280, 336, 384
500, 600
720
Digit 17/C - Any Coating on All Louver Cone Diffusers = $248 list price
Notes:
1. Surface preparation: sandblasting, except coils which are chemically cleaned. Inside and outside of each casing, fan blade and heating coil are special coated. Motors cannot
be special coated.
2. Epoxy Coating Coating (Digit 16/R)
16/R): Two coats on all subassemblies and one coat on assembled. Unit force cured at 150°F.
3. Epoxy Phenolic Coating (Digit 16/T)
16/T): Two coats on all subassemblies and one coat on assembled. Unit force cured at 150°F.
4. Baked Phenolic Coating (Digit 16/W)
16/W): Four coats on all surfaces. Baked at 325°F on intermediate coats and 425°F on cure. Units are reshipped in original cartons.
5. To order, enter appropriate in digit 16 of model number.

Table PTAC/UH-30-B— Packed Stock Model S Unit Heater Order Numbers & Equivalent Production Model Numbers
Horizontal Model S Unit Heaters Constant Speed
Stock Order Production Order
Size Order No. Type Model No. Type Notes
18S 136-0101-01 STK UHSA018S8EAA1T0000000 PRD 1
20S2* 136-0102-01 STK UHSA020S2EAA1T0000000 PRD 1
38S 136-0103-01 STK UHSA038S8EAA1T0000000 PRD 1
42S 136-0104-01 STK UHSA042S8EAA1T0000000 PRD 1
60S 136-0105-01 STK UHSA060S8EAA1T0000000 PRD 1
70S 136-0106-01 STK UHSA070S8EAA1T0000000 PRD 1
90S 136-0107-01 STK UHSA090S8EAA1T0000000 PRD 1
100S 136-0108-01 STK UHSA100S8EAA1T0000000 PRD 1
126S 136-0109-01 STK UHSA126S8EAA1T0000000 PRD 1
168S 136-0110-01 STK UHSA168S8EAA1T0000000 PRD 1
186S 136-0111-01 STK UHSA186S8EAA1T0000000 PRD 1
230S 136-0112-01 STK UHSA230S8EAA1T0000000 PRD 1
260S 136-0113-01 STK UHSA260S8EAA1T0000000 PRD 1
320S 136-0114-01 STK UHSA320S8EAA1T0000000 PRD 1
354S 136-0115-01 STK UHSA354S8EAA1T0000000 PRD 1
Notes:
1. For steam or hot water coils made from .031 copper tubes. Aluminum fins (*108 per foot) and steel pipe headers. Fans made with steel hubs and aluminum blades. Sleeve
bearing motors are 115/60/1. TEAOM with TOP and class B insulation. Type No. 1 motor mount (wire guard) furnished. Variable speed motors furnished on sizes 18S thru 100S
as standard. Requires a solid-state speed control which must be ordered separately. Unit casings top, front, back and sides made from steel with adjustable louvers
phosphatized and painted with a blue-gray baked enamel finish.
*Size 20S2 stock unit furnished with 132 fins per foot as standard.

Table PTAC/UH-30-C— Packed Stock Model P Unit Heater Order Numbers & Equivalent Production Model Numbers
Vertical Model P Unit Heaters Constant Speed
Stock Order Production Order
Size Order No. Type Model No. Type Notes
42P 136-0143-01 STK UHPA042P4CAA1T0000000 PRD 1
64P 136-0144-01 STK UHPA064P4CAA1T0000000 PRD 1
80P 136-0145-01 STK UHPA080P4CAA1T0000000 PRD 1
102P 136-0146-01 STK UHPA102P4CAA1T0000000 PRD 1
122P 136-0147-01 STK UHPA122P4CAA1T0000000 PRD 1
146P 136-0148-01 STK UHPA146P4CAA1T0000000 PRD 1
166S 136-0149-01 STK UHPA166P4CAA1T0000000 PRD 1
202P 136-0150-01 STK UHPA202P4CAA1T0000000 PRD 1
252P 136-0151-01 STK UHPA252P4CAA1T0000000 PRD 1
280P 136-0152-01 STK UHPA280P4CAA1T0000000 PRD 1
336P* 136-0153-01 STK UHPA336P4CAA1T0000000 PRD 1
Notes:
1. For steam or hot water coils made from .025 copper tubes. Aluminum fins (144 per foot) and steel pipe headers. Fans made with steel hubs and aluminum blades. Sleeve
bearing motors are provided for 1/20 & 1/8 HP ranges and ball bearing motors provided for 1/6, 1/4, & 1/2 HP ranges are 115/60/1. TE with TOP and class B insulation. Steel
motor mount furnished. Variable speed motors furnished on sizes 42P thru 102P as standard. Requires a solid-state speed control which must be ordered separately. Casings
made from two steel plates with the top plate having air ports as standard, phosphatized and painted with a blue-gray baked enamel finish.
*Size 336P stock unit uses a 230/460/60/3, ball bearing, TE with class B insulation motor as standard.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-30 information.
Electric Unit Heaters
Voltage Control

Table PTAC/UH-31-A— Standard with 24V Control Transformer and Contactor


Order Element Std.
kW No. Element & Motor Amp Control Ship
Rating UHEC 236- Phase Voltage Rating Voltage wt lbs
031AACA -246 1 208 15.9 24 25
3.3 kW 031CACA -248 1 277 11.9 24 25
033DACA -182 3 480 4.0 24 25
052AACA -250 1-3 208 24.1 24 25
5.0 kW 052BACA -252 1-3 240/208 20.9/18.1 24 25
053DACA -194 3 480 6.1 24 25
072AACA -196 1-3 208 36.1 24 50
072BACA -198 1-3 240/208 31.3/27.1 24 50
7.5 kW 071CACA -200 1 277 27.1 24 50
073DACA -202 3 480 9.1 24 50
102AACA -204 1-3 208 47.8 24 50
102BACA -206 1-3 240/208 42.2/36.1 24 50
10 kW 101CACA -208 1 277 36.1 24 50
103DACA -210 3 480 12.1 24 50
153AACA -212 3 208 41.7 24 65
15 kW 153BACA -214 3 240/208 36.1/31.3 24 65
153DACA -216 3 480 18.1 24 65
203BACA -218 3 240/208 47.8/41.1 24 65
20 kW 203DACA -220 3 480 24.1 24 65
253AACA -222 3 208 69.5 24 120
25 kW 253BACA -224 3 240/208 60.2/52.1 24 120
253DACA -226 3 480 30.1 24 120
303AACA -228 3 208 83.4 24 120
30 kW 303DACA -232 3 480 36.2 24 120
403BACA -236 3 240/208 96.4/83.4 24 120
40 kW 403DACA -238 3 480 47.0 24 120
50 kW 503DACA -244 3 480 60.3 24 120
1. Supply wire must have 75°C minimum insulation.
2. Each Electric Unit Heater in Table PTAC/UH-31-A is provided with a factory installed Transformer and Contactor as standard for 24V control voltage.
3. All 25-50 kW units are factory wired for two-stage operation as standard. To operate on two-stage, a two-stage thermostat must be ordered.
4. All 25-50 kW units are equipped with two-speed motors and factory installed Speed Switches as standard.

Table PTAC/UH-31-B— Standard Units for Line Voltage Control


Order Element Std.
kW No. Element & Motor Amp Control Ship
Rating UHEC 236- Phase Voltage Rating Voltage wt. lbs
031A0C0 -172 1 208 15.9 208 25
031B0C0 -174 1 240/208 13.7/11.9 240/208 25
3.3 kW 032A0C0 -176 1-3 208 15.9 208 25
032B0C0 -178 1-3 240/208 13.7/11.9 240/208 25
031C0C0 -180 1 277 11.9 277 25
051A0C0 -184 1 208 24.1 208 25
051B0C0 -186 1 240/208 20.9/18.1 240/208 25
5.0 kW 052A0C0 -188 1-3 208 24.1 208 25
052B0C0 -190 1-3 240/208 20.9/18.1 240/208 25
051C0C0 -192 1 277 18.1 277 25
1. Supply wire must have 75°C minimum insulation.
2. Transformers and Contactors are not furnished for these units.
3. The control voltage is line voltage.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-31 Effective 1/1/06
Electric Unit Heaters
Voltage Control

Table PTAC/UH-32-A—Production with 24V Control Voltage Transformer & Contactor


Order Element Std.
kW No. Element & Motor Amp Control Ship
Rating UHEC 236- Phase Voltage Rating Voltage wt. lbs
031BACA SPEC 1 240/208 13.7/11.9 24 25
3.3 kW 032AACA SPEC 1-3 208 15.9 24 25
032BACA SPEC 1-3 240/208 13.7/11.9 24 25
051AACA SPEC 1 208 24.1 24 25
5.0 kW 051BACA SPEC 1 240/208 20.9/18.1 24 25
051CACA SPEC 1 277 18.1 24 25
30 kW 303BACA SPEC 3 240/208 72.3/62.5 24 120
40 kW 403AACA SPEC 3 208 111.2 24 120
503AACA SPEC 3 208 139.0 24 120
50 kW 503BACA SPEC 3 240/208 120.5/104.3 24 120
1. Supply wire must have 75°C minimum insulation.
2. Each Electric Unit Heater in Table PTAC/UH-32-A is provided with a factory installed Transformer and Contactor as standard for 24V control voltage.
3. All 30-50 kW units are factory wired for two-stage operation as standard. To operate on two-stage, a two-stage thermostat must be ordered.
4. All 30-50 kW units are equipped with two-speed motors and factory installed Speed Switches as standard.
5. Use the model number to order.

Table PTAC/UH-32-B—Production Units for Line Voltage Control with Contactor


Order Element Std.
kW No. Element & Motor Amp Control Ship
Rating UHEC 236- Phase Voltage Rating Voltage wt. lbs
031A0CA SPEC 1 208 15.9 208 25
031B0CA SPEC 1 240/208 13.7/11.9 240/208 25
3.3 kW 032A0CA SPEC 1-3 208 15.9 208 25
032B0CA SPEC 1-3 240/208 13.7/11.9 240/208 25
031C0CA SPEC 1 277 11.9 277 25
051A0CA SPEC 1 208 24.1 208 25
051B0CA SPEC 1 240/208 20.9/18.1 240/208 25
5.0 kW 052A0CA SPEC 1-3 208 24.1 208 25
052B0CA SPEC 1-3 240/208 20.9/18.1 240/208 25
051C0CA SPEC 1 277 18.1 277 25
1. Supply wire must have 75°C insulation minimum.
2. Transformer not provided for these units.
3. Contactor provided as standard for these units.
4. Use the model number to order.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-32 information.
Electric Unit Heaters
Control Options
(Field Installed)
Table1 PTAC/UH-33-A— Field Installed Control Options (See Tables PTAC/UH-33-A, PTAC/UH-33-B,PTAC/UH-34-A for Control Prices)
Unit Thermostat Louver
Mounted Summer w/Summer Cone
Disconnect Fan Fan Stratification Mounting Diffuser
Unit Switch Thermostats Switches Switch Thermostat Brackets 7.50-50 kW
Order Single- Three- Unit Wall Unit Wall Wall Unit Wall vert
2
Number Phase Phase MTD MTD MTD MTD MTD MTD MTD vert horiz only
236- 172 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA
174 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA
246 700* NA 705* 716* 711* -720 NA 710* 718 726* 723* NA
3 7
176 -700* -701* -705 * -714 * -711* -719 NA -710* -718 -726* -723* NA
178 -700* -701* -7053* -7147* -711* -719 NA -710* -718 -726* -723* NA
180 -700* NA -705* -714* -711* -719 NA -NA -718 -726* -723* NA
248 -700* NA -705* -716* -711* -720* NA -710* -718 -726* -723* NA
182 NA -701* -705* -716* -712* -720* -721 -709 NA -726* -723* NA
236- 184 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA
250 -700* -701* -7053* -716* -711* 719 NA -710* -718 -726* -723* NA
186 -700* NA -705* -714* -711* -719 NA -710* -718 -726* -723* NA
3 7
188 -700* -701* -705 * -714 * -711* -719 NA -710* -718 -726* -723* NA
190 -700* -701* -7053* -7147* -711* -719 NA -710* -718 -726* -723* NA
252 -700* -701 -7053* -716* -711* 719 NA -710* -718 -726* -723* NA
192 -700* NA -705* -714* -711* -719 NA NA -718 -726* -723* NA
194 NA -701* -705* -716* -712* -720* -721 -709 NA -726* -723* NA
236-196 -703 -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
198 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
200 -703 — -705* -716* -711* 719 -721 -NA -718 -727* -724* -920*
202 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*
236- 204 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
206 -703 -702* -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
208 -703 NA -705* -716* -711* 719 -721 -NA -718 -727* -724* -920*
210 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*
236- 212 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
214 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
216 NA -701* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*
236- 218 NA -704 -705* -716* -711* 719 -721 -710* -718 -727* -724* -920*
220 NA -702* -705* -716* -712* -720* -721 -709 NA -727* -724* -920*
236- 222 NA NA -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922*
224 NA -704 -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922*
4 5 6
226 NA -702* -705 * -716 * -712* -720* -721 -709 NA -728* -725* -922*
236- 228 NA NA -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922*
232 NA -704 -7054* -7165* -712* -720* -7216 -709 NA -728* -725* -922*
236 NA NA -7054* -7165* -711* 719 -7216 -710* -718 -728* -725* -922*
238 NA -704 -7054* -7165* -712* -720* -7216 -709 NA -728* -725* -922*
236- 244 NA -704 -7054* -7165* -712 -720* -7216 -709 NA -728* -725* -922*
Notes:
1. Three-phase electric unit heaters need two-pole thermostats for line voltage service.
2. Unit mounted controls are always field installed by others.
3. For three-phase operation use 236-706.
4. For two-stage operation use 236-708.
5. For two-stage operation use 236-717.
6. For two-stage operation use 236-722.
7. For three-phase operation use 236-715.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-33 Effective 1/1/06
Electric Unit Heaters
Control Options
(Field Installed)
Table PTAC/UH-34-A— Control Options (Unit Mounted in Field)
Model No. Order No. Description
Power Disconnect Switch (Unit Mounted)1
DCS 252 236-700 2 Pole 25 Amp 120-277 VAC Res.
DCS 253 236-701 3 Pole 25 Amp 120-600 VAC Res.
DCS 323 236-702 3 Pole 32 Amp 120-600 VAC Res.
DCS 632 236-703 2 Pole 63 Amp 120-600 VAC Res.
DCS 633 236-704 3 Pole 63 Amp 120-600 VAC Res.
Line Voltage Thermostats (Unit Mounted)
T5100 236-705 SPST 25 Amp 120-277V 45 - 90°F2
T5102 236-706 DPST 25 Amp 120-277V 45 - 90°F3
Low Voltage Thermostats 24V
T5100R 236-705 SPST Low Voltage 24V 45 - 90°F (3-20 kW units) (single-stage)
T5122 236-708 Two-stage Low Voltage 24V 45 - 90°F (25-50 kW units)
Stratification Thermostat4
TC5102 236-709 SPST Low Volt-Pilot 24V Duty (w/relay) 70 - 130°F5
TC5103 236-710 SPST Line Voltage 120/277V 70 - 130°F6
Summer Fan Switch
FS5101 236-711 SPST Line Voltage 120-277V
FS5102 236-712 SPST Line Voltage 120-600V
Notes:
1. Use two pole disconnect switch only for single-phase operation and a three pole disconnect switch only for three-phase operation. Both are factory installed.
2. Ok for single or three-phase.
3. Must be used on dual (single to three-phase) units when three-phase is required. Ok to use on single or three-phase units.
4. Wall thermostat must be used when unit mounted stratification thermostat is required. The stratification thermostat activates the fan only for heat recovery.
5. To be used on 480V three-phase units only. Not available for 277V single-phase units.
6. Not available for 480V three-phase and 277V single-phase units only.

Table PTAC/UH-34-B— Control Options (Wall Mounted)


Model No. Order No. Description
Line Voltage Thermostats
TW1510 236-714 SPST 30 amp 120-240V 25 Amp 277V 40 - 90°F1
TW1512 236-715 DPST 30 amp 120-240V 25 Amp 277V 40 - 90°F2
Low Voltage Thermostat
A6176 236-716 SPST 24V 50 - 80°F
TW123 236-717 Two-stage 24V 45 - 85°F (25-50 kW units)
Stratification Thermostat
TC1602 236-718 SPST Line Voltage 120-240V 70 - 140°F3
Summer Fan Switch
FSW5111 236-719 SPST Line Voltage 120-600V
FSW5112 236-720 SPST Low Voltage w/relay 24V
Low Voltage T’stat w/Summer Fan Switch
TFS5101 236-721 SPST Low Voltage 40 - 90°F4 , 6
TFS5102 236-722 Two-stage Low Voltage 45 - 85°F 24V5
1. Must be used on single-phase units only.
2. Ok for use on single or three-phase units.
3. Do not use with 480V three-phase units only.
4. Not available for 3.3 and 5.0 kW, 208/1, 277/1, 240/208/1, 208/1-3 units must have transformer and contactor to be ok and 240/208/1-3V/phase units. Ok for use on 3.3 and 5.0 480/3 volt/
phase units. All 7.5 thru 50 kW size units, volts and phase units are ok.
5. For use on 25 - 50 kW size units only.
6. Comes with a relay as standard, can be factory installed if shown on the order.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-34 information.
Electric Unit Heaters
Accessories

Table PTAC/UH-35-A—Accessories
Model No. Order No. Description wt. lbs.
Wall/Ceiling Mounting Bracket (horiz. discharge)
A5105 236-723 2-5 kW Bracket 6.0
A5120 236-724 7-20 kW Bracket 9.0
A5150 236-725 25-50 kW Bracket 11.0
Dust Shield (horiz. discharge)
DS5105 233-740 3.3-5 kW Dust Shield .5
DS5120 233-741 7.5-20 kW Dust Shield .5
DS5150 233-742 25-50 kW Dust Shield .5
Ceiling Mtg. Bracket (vert. discharge)
V5105 236-726 2-5 kW Bracket 9.0
V5120 236-727 7-20 kW Bracket 13.0
V5150 236-728 25-50 kW Bracket 13.0
Louver Cone Diffusers (vert. discharge only)
RD5120 236-920 7-20 kW Diffuser 8.0
RD5150 236-922 25-50 kW Diffuser 12.0
Anemostat Diffusers (vert. discharge only)
AD5120 233-730 7-20 kW ANEMOSTAT 9.0
AD5150 233-731 25-50 kW ANEMOSTAT 13.0

Table PTAC/UH-35-B—OSHA Fan Guards

OFG5101 233-930 3-5 kW


OFG5102 233-932 7-20 kW
OFG5103 233-935 25-50 kW

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-35 Effective 1/1/06
Electric Unit Heaters
Hose Down Corrosion Resistant

Table PTAC/UH-36-A— Hose Down Corrosion Resistant Unit Heaters


kW Order No. Element & Ship
Rating UHRA 233 Element Phase Motor Voltage Amp Rating wt. lbs
031AAAT -600 1 208 15.9
033AAAT -602 3 208 9.2
031GAAT -603 1 240 13.8
3.3 kW 033GAAT -604 3 240 8.0 45
031CAAT -606 1 277 12.0
033DAAT -608 3 480 4.0
033FAAT -609 3 600 3.2
051AAAT -610 1 208 24.1
053AAAT -612 3 208 13.9
051GAAT -614 1 240 20.9
5.0 kW 053GAAT -615 3 240 12.1 45
051CAAT -616 1 277 18.1
053DAAT -617 3 480 6.1
053FAAT -618 3 600 4.9
071AAAT -620 1 208 36.1
073AAAT -621 3 208 20.9
071GAAT -623 1 240 31.3
7.5 kW 073GAAT -625 3 240 18.1 45
071CAAT -626 1 277 27.1
073DAAT -627 3 480 9.1
073FAAT -629 3 600 7.3
101AAAT -631 1 208 48.1
103AAAT -633 3 208 27.8
101GAAT -634 1 240 41.7
10 kW 103GAAT -635 3 240 24.1 55
101CAAT -637 1 277 36.2
103DAAT -638 3 480 12.1
103FAAT -639 3 600 9.7
151AAAT -651 1 208 72.2
153AAAT -653 3 208 41.7
151GAAT -654 1 240 62.5
15 kW 153GAAT -655 3 240 36.2 55
153DAAT -658 3 480 18.1
153FAAT -659 3 600 14.5
203AAAT -660 3 208 55.6
20 kW 203GAAT -662 3 240 48.2 85
203DAAT -664 3 480 24.1
203FAAT -666 3 600 19.3
253AAAT -661 3 208 69.5
25 kW 253GAAT -663 3 240 60.3 85
253DAAT -665 3 480 30.2
253FAAT -667 3 600 24.1
303AAAT -670 3 208 83.4
30 kW 303GAAT -672 3 240 72.3 85
303DAAT -673 3 480 36.2
303FAAT -674 3 600 29.0
40 kW 403DAAT -677 3 480 48.2 130
403FAAT -678 3 600 38.6
48 kW 483DAAT -685 3 480 57.9 130
483FAAT -687 3 600 46.3
1. Includes as standard the following controls factory installed and wired. (24V transformer, pilot light, thermostat, heat- off-fan switch, fan delay relay and disconnect.)
2. Corrosion-resistant in high humidity and water-saturated areas in non-hazardous locations and atmospheres.
3. 15 kW, 277V single-phase heaters are not available.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-36 information.
Electric Unit Heaters
Accessories

Table PTAC/UH-37-A— Accessories


Model No. Order No. Description wt. lbs.
Wall Mounting Kit
A5520 233-690 3.3-15 kW Bracket1
W5520 233-691 3.3-15 kW Bracket 2 28
W5550 233-692 20-48 kW Bracket2
Ceiling Mtg. Kit 3
H5550 233-694 3.3-48 kW Hanging Bracket. 6
Pipe Mtg. Kit 4
P5520 233-695 3.3-15 kW Bracket
P5550 233-696 20-48 kW Bracket 39
1. One piece bracket for wall mounting for sizes 3.3-15 kW only. Manufactured from stainless steel and epoxy coated.
2. Contains wall bracket and mounting arm, ideal for use in buildings that have substantial walls. Arm only can also be bolted directly to structural steel. Manufactured from cast iron steel and
epoxy coated.
3. Requires Roof or Ceiling Structure. ½” pipe, cut and threaded is required furnished by others.
4. 3 ½” pipe 4” O.D. supplied by others.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-37 Effective 1/1/06
Electric Unit Heaters
UHXA

Table PTAC/UH-38-A— UHXA with 24V Control Voltage 1


kW Order No. Element + Mtr Amp Control
Rating UHXA 233- Volts/Phase Rating Voltage wt. lbs.
031A1B -110 208/1 16.3 24 167
033A1B -112 208/3 9.8 24 167
3 kW 031B1B -114 240/1 14.8 24 167
033B1B -116 240/3 8.6 24 167
033D1B -118 480/3 4.3 24 167
033F1B -119 600/3 3.5 24 167
051A1B -120 208/1 26.0 24 167
053A1B -122 208/3 15.4 24 167
5 kW 051B1B -124 240/1 23.1 24 167
053B1B -126 240/3 13.4 24 167
053D1B -128 480/3 6.7 24 167
053F1B -129 600/3 5.4 24 167
071A1B -130 208/1 38.0 24 167
073A1B -132 208/3 22.3 24 167
7.5 kW 071B1B -134 240/1 33.6 24 167
073B1B -136 240/3 19.4 24 167
073D1B -138 480/3 9.7 24 167
073F1B -139 600/3 7.8 24 167
103A1B -140 208/3 29.3 24 193
101B1B -142 240/1 44.0 24 193
10 kW 103B1B -144 240/3 25.5 24 193
103D1B -146 480/3 12.7 24 193
103F1B -148 600/3 10.2 24 193
153A1B -150 208/3 43.5 24 225
15 kW 153B1B -151 240/3 38.1 24 225
153D1B -152 480/3 19.0 24 225
153F1B -153 600/3 15.2 24 225
20 kW 203D1B -154 480/3 25.1 24 225
203F1B -155 600/3 20.0 24 225
25 kW 253D1B -156 480/3 31.1 24 225
253F1B -157 600/3 24.9 24 225
*Supply conductors must be suitable for 90°C
1. 24V control voltage is standard and includes built-in contactor and 24V control transformer.

Table PTAC/UH-38-B— UHXA with 120V Control Voltage


kW Order No. Element + Mtr Amp Control
Rating UHXA 233- Volts/Phase Rating Voltage wt. lbs.
031A2B -111 208/1 16.3 120 167
033A2B -113 208/3 9.8 120 167
3 kW 031B2B -115 240/1 14.8 120 167
033B2B -117 240/3 8.6 120 167
033D2B -121 480/3 4.3 120 167
051A2B -125 208/1 26.0 120 167
053A2B -127 208/3 15.4 120 167
5 kW 051B2B -131 240/1 23.1 120 167
053B2B -133 240/3 13.4 120 167
053D2B -135 480/3 6.7 120 167
071A2B -141 208/1 38.0 120 167
073A2B -143 208/3 22.3 120 167
7 kW 071B2B -145 240/1 33.6 120 167
073B2B -147 240/3 19.4 120 167
073D2B -149 480/3 9.7 120 167
103A2B -159 208/3 29.3 120 193
101B2B -160 240/1 44.0 120 193
10 kW 103B2B -161 240/3 25.5 120 193
103D2B -162 480/3 12.7 120 193
153A2B -164 208/3 43.5 120 225
15 kW 153B2B -165 240/3 38.1 120 225
153D2B -166 480/3 19.0 120 225
20 kW 203D2B -168 480/3 25.1 120 225
25 kW 253D2B -170 480/3 31.1 120 225
* Supply conductors must be suitable for 90°C
1. 120V control voltage is standard and includes built-in contactor and 120V control transformer.
2. Not available for 600V heaters.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-38 information.
Electric Unit Heaters
UHXA Control Options Mounting
Bracket Kits
Table PTAC/UH-39-A—UHXA with 208 or 240 Volt Control Voltage
kW Order No. Element + Mtr Amp Control
Rating UHXA 233- Volts/Phase Rating Voltage wt. lbs.
031A3B -260 208/1 16.3 208 167
033A3B -262 208/3 9.8 208 167
3 kW 031B4B -264 240/1 14.8 240 167
033B4B -266 240/3 8.6 240 167
051A3B -268 208/1 26.0 208 167
053A3B -270 208/3 15.4 208 167
5 kW 051B4B -272 240/1 23.1 240 167
053B4B -274 240/3 13.4 240 167
071A3B -276 208/1 38.0 208 167
073A3B -278 208/3 22.3 208 167
7 kW 071B4B -280 240/1 33.6 240 167
073B4B -282 240/3 19.4 240 167
103A3B -284 208/3 29.3 208 193
10 kW 101B4B -286 240/1 44.0 240 193
103B4B -288 240/3 25.5 240 193
153A3B -290 208/3 43.5 208 225
15 kW 153B4B -292 240/3 38.1 240 225
* Supply conductors must be suitable for 90°C
1. Not available for 480 and 600 volt heaters.

Table PTAC/UH-39-B—Unit Mounted Control Option (Factory Installed)


Model No. Order No. Description
Unit Mounted Thermostat
T 233-010 Explosion Proof 45-90°F
1. Will operate on all voltages.

Table PTAC/UH-39-C—Wall Mounted Control Option


Model No. Order No. Description wt. lbs.
TW161 233-015 Explosion ProofThermostat SPST 40-90°F 22 Amps, 5
125-277 VAC ¾ HP @ 125 VAC, 1½ HP @ 250-277 VAC*
TW162 233-019 Explosion ProofThermostat DPST 40-90°F 22 Amps, 5
125-277 VAC ¾ HP @ 125 VAC, 1½ HP @ 250-277 VAC*
* Makes on fall in the temperature.
OK for use on units with 24V and 120V control voltage.

Table PTAC/UH-39-D—Mounting Bracket Kits


Model No. Order No. Description wt. lbs.
Wall Mounting Bracket1
HLWM37 233-020 3, 5 and 7.5 kW Bracket 27
HLWM10 233-022 10 kW Bracket 28
HLWM1525 233-026 15, 20 and 25 kW Bracket 29
Ceiling Mounting Bracket 2
HLHM 233-033 All Sizes 5
Floor Mounting Bracket 3
HLPM37 233-041 3, 5 and 7.5 kW Bracket 37
HLPM10 233-044 10 kW Bracket 38
HLPM1525 233-049 15, 20 and 25 kW Bracket 40
1. Wall Bracket, ideal for use in buildings that have substantial walls. Note: The arm only can be bolted directly to structural steel.
2. Ceiling Mounting Bracket - Must have adequate overhead structure to mount to. Note: ½” pipe, cut and threaded and supplied by others is required.
3. Floor Mounting Bracket should be used in buildings with insufficient strength to use other types of mounting brackets.
To be used with 3½” schedule 40 pipe (4 OD supplied by others).

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-39 Effective 1/1/06
Electric Unit Heaters
Ceiling Heaters, Plaster Trim and
Thermostats
Table PTAC/UH-40-A—Series 70 Electric Ceiling Surface Heaters
kW Order No. Element + Element Mounting Amp
Rating UHCA 233- Motor Voltage Phase Application Rating
021A7A -300 208 1 Surface 9.6
2 kW 021B7A -302 240 1 Surface 8.3
021C7A -304 277 1 Surface 7.2
031A7A -306 208 1 Surface 14.4
3 kW 031B7A -308 240 1 Surface 12.5
031C7A -310 277 1 Surface 10.8
041A7A -312 208 1 Surface 19.2
041B7A -314 240 1 Surface 16.7
4 kW 041C7A -316 277 1 Surface 14.4
043A7A -318 208 3 Surface 11.1
043B7A -320 240 3 Surface 9.6
051A7A -322 208 1 Surface 24.1
051B7A -324 240 1 Surface 20.8
5 kW 051C7A -326 277 1 Surface 18.1
053A7A -328 208 3 Surface 13.9
053B7A -330 240 3 Surface 12.1
Surface Mounted Ceiling Heaters — Series 70 designed to be mounted to standard 4 inch ceiling box furnished and installed by others. Approximate weight 32 lbs. Packed and shipped as
complete unit.

Table PTAC/UH-40-B—Series 80 Electric Ceiling Recessed Heaters


kW Order No. Element + Element Mounting Amp
Rating UHCA 233- Motor Voltage Phase Application Rating
021A8A -331 208 1 Recessed 9.6
2 kW 021B8A -333 240 1 Recessed 8.3
021C8A -335 277 1 Recessed 7.2
031A8A -337 208 1 Recessed 14.4
3 kW 031B8A -339 240 1 Recessed 12.5
031C8A -341 277 1 Recessed 10.8
041A8A -343 208 1 Recessed 19.2
041B8A -345 240 1 Recessed 16.7
4 kW 041C8A -347 277 1 Recessed 14.4
043A8A -349 208 3 Recessed 11.1
043B8A -351 240 3 Recessed 9.6
051A8A -353 208 1 Recessed 24.1
051B8A -355 240 1 Recessed 20.8
5 kW 051C8A -357 277 1 Recessed 18.1
053A8A -359 208 3 Recessed 13.9
053B8A -361 240 3 Recessed 12.1
Recessed Mounted Ceiling Heaters — Series 80 packed and shipped as a complete unit. Contains junction box, heater box and grille.
For finished ceiling application use plaster trim which is an optional accessory. Approximate weight 35 lbs.

Table PTAC/UH-40-C—Plaster Trim


Model No. Order No. Description
*PT3480 233-363 PlasterTrim
*Use PT3480 plaster trim for Series 80 recessed heaters when recessed in a hard finished ceiling.

Table PTAC/UH-40-D—Line Voltage Thermostats (Wall Mounted)


Model No. Order No. Description
*TW148 233-301 DPST 25 AMP 120-240V, 18 Amp 277V for single-phase
*TW146 233-303 DPST 25 AMP 120-240V, 18 Amp 277V,Tamper Resistant for single-phase
**TW1512 233-715 DPST 30 AMP 120-240V, 25 Amp 277V, 40-90°F for 3 Phase
TW147 233-311 SPST 25 AMP 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors
TW145 233-313 SPST 25 AMP 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors,
Tamper Resistant
*For use with one unit single phase and more than one unit single-phase. Makes and breaks two poles simultaneously.
**For use with one unit three phase only and more than one unit three or single-phase. Do not exceed thermostat’s rated ampacity.
Makes and breaks two poles simultaneously. Three phase units with TW1512 line voltage thermostat does not need a control panel.

Table PTAC/UH-40-E—Low Voltage Thermostat (Wall Mounted)


Model No. Order No. Description
*A6176 236-716 Deluxe 24V, Adjustable Anticipation Positive Off Switch,Thermometer, HoneywellT87F
A6280 233-323 Tamperproof Kit for A6176
*Three-phase units must have a control panel when used with a wall mounted low voltage thermostat.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-40 information.
Electric Unit Heaters
Thermal Relay, Control Panels

Table PTAC/UH-41-A—Thermal Relay with Built-in Line Voltage/24V Transformer*


Model No. Order No. Description
A6281 233-370 120, 208, 240 or 277V (Specify Voltage) SPST
A6283 233-373 120, 208, 240 or 277V (Specify Voltage) 2 Circuit
*For remote mounting only, for use with low voltage A6176 thermostat.

Table PTAC/UH-41-B—Control Panels — 24V*


Model No. Order No. Primary Voltage Dimensions No. Of Contactors
AF3401-24 233-332 208
AH3401-24 233-334 240 12”x12”x4 ½” 1
AG3401-24 233-336 277
AF3402-24 233-338 208
AH3402-24 233-340 240 15”x15”x4 ½” 2
AG3402-24 233-342 277
AF3403-24 233-344 208
AH3403-24 233-346 240 20”x20”x4 ½” 3
AG3403-24 233-348 277
*For control of one or more single or three phase ceiling heaters from one 24V thermostat. Panels are in NEMA one enclosures and have one or more 30 Amp, three pole, 600 VAC
contactor(s), operating voltage to control voltage transformer and transformer fusing. (User must provide separate circuit for each contactor.)

Table PTAC/UH-41-C—Control Panels — 120V*


Model No. Order No. Primary Voltage Dimensions No. of Contactors
AF3401-120 233-350 208
AH3401-120 233-352 240 12”x12”x4 ½” 1
AG3401-120 233-354 277
AF3402-120 233-356 208
AH3402-120 233-358 240 15”x15”x4 ½” 2
AG3402-120 233-360 277
AF3403-120 233-362 208
AH3403-120 233-364 240 20”x20”x4 ½” 3
AG3403-120 233-366 277
*For control of one or more single or three phase ceiling heaters from one 120V thermostat. Panels are in NEMA one enclosures and have one or more 30 Amp, three pole, 600 VAC
contactor(s), operating voltage to control voltage transformer and transformer fusing. (User must provide separate circuit for each contactor.)

CONTROL PANELS — 1-PHASE ELECTRIC CEILING HEATERS


1 – Contactor handle 3 Units.
2 – Contactors handle 6 Units.
3 – Contactors handle 9 Units.
Note: Make sure you do not exceed total ampacity rating.

3-PHASE ELECTRIC CEILING HEATERS


1 – Contactor handle 1 Unit.
2 – Contactors handle 2 Units.
3 – Contactors handle 3 Units.
Note: Make sure you do not exceed total ampacity rating.
Note: Each control panel uses three pole contactors rated at 30 Amps per pole.

Table PTAC/UH-41-D—Unit Mounted Controls for Series 80 Ceiling Heaters Only


Model No. Order No. Description
T2 233-382 Thermostat Double Pole
S 233-383 Disconnect Switch
R1 233-385 24VTransformer/Relay
R 233-387 Line Voltage Relay
R2 233-389 120V Relay
1. All controls factory installed and wired on the heaters.
2. Thermostats are tamperproof.
3. Fan purge (off delay to dissipate residual heat on shutoff) supplied as a standard control on heaters with factory installed options.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-41 Effective 1/1/06
Electric Unit Heaters
Electric Wall Mounted

Table PTAC/UH-42-A—Electric Wall Mounted Unit Heaters — Series 20 '


Order Element
kW No. + Motor Element Ship Amp
Rating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating
021A2AT -400 208 1 9.6 9.6
2000W 021B2AT -402 240 1 8.3 41 8.3
021C2AT -404 277 1 7.2 7.2
031A2AT -406 208 1 14.4 14.4
3000W 031B2AT -408 240 1 12.5 41 12.5
031C2AT -410 277 1 10.8 10.8
041A2AT -412 208 1 19.2 19.2
041B2AT -414 240 1 16.7 16.7
4000W 041C2AT -416 277 1 14.4 41 14.4
043A2AT -418 208 3 11.1 11.1
043B2AT -420 240 3 9.6 9.6
051A2AT -422 208 1 24.0 24.1
051B2AT -424 240 1 20.8 20.8
5000W 051C2AT -426 277 1 18.0 41 18.1
053A2AT -428 208 3 13.9 13.9
053B2AT -430 240 3 12.0 12.1
All Sizes 3420 -440 Wall Box5 9 —
1. Only contactor can be built-in on Series 20 Wall Heaters.
2. Factory installed (T) thermostat is standard.
3. Wall box must be ordered.

Table PTAC/UH-42-B—Electric Wall Mounted Unit Heaters without Unit Mounted Thermostat
Order Element
kW No. + Motor Element Ship Amp
Rating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating
021A2A0 n/a 208 1 9.6 9.6
2000W 021B2A0 n/a 240 1 8.3 41 8.3
021C2A0 n/a 277 1 7.2 7.2
031A2A0 n/a 208 1 14.4 14.4
3000W 031B2A0 n/a 240 1 12.5 41 12.5
031C2A0 n/a 277 1 10.8 10.8
041A2A0 n/a 208 1 19.2 19.2
041B2A0 n/a 240 1 16.7 16.7
4000W 041C2A0 n/a 277 1 14.4 41 14.4
043A2A0 n/a 208 3 11.1 11.1
043B2A0 n/a 240 3 9.6 9.6
051A2A0 n/a 208 1 24.0 24.1
051B2A0 n/a 240 1 20.8 20.8
5000W 051C2A0 n/a 277 1 18.0 41 18.1
053A2A0 n/a 208 3 13.9 13.9
053B2A0 n/a 240 3 12.0 12.1
All Sizes 3420 233-440 Wall Box5 9
1. Only contactor can be built-in on Series 20 Wall Heaters.
2. Wall box must be ordered.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-42 information.
Electric Unit Heaters
Electric Wall Mounted and
Extension Sleeves
Table PTAC/UH-43-A— Electric Wall Mounted Unit Heaters — Series 50 1
Order Element
kW No. + Motor Element Ship Amp
Rating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating
021A5AT -431 208 1 9.6 9.6
2000W 021B5AT -433 240 1 8.3 54 8.3
021C5AT -435 277 1 7.2 7.2
031A5AT -437 208 1 14.4 14.4
3000W 031B5AT -439 240 1 12.5 55 12.5
031C5AT -441 277 1 10.8 10.8
041A5AT -443 208 1 19.2 19.2
041B5AT -445 240 1 16.7 16.7
4000W 041C5AT -447 277 1 14.4 55 14.4
043A5AT -449 208 3 11.1 11.1
043B5AT -451 240 3 9.6 9.6
051A5AT -453 208 1 24.0 24.1
051B5AT -455 240 1 20.8 20.8
5000W 051C5AT -457 277 1 18.0 55 18.1
053A5AT -459 208 3 13.9 13.9
053B5AT -461 240 3 12.0 12.1
All Sizes 3450 -450 Wall Box5 11 —
1. If circuit breaker and/or transformers are required, the Series 50 wall heater must be ordered.
2. Factory installed (T) thermostat is standard.
3. Wall box must be ordered.

Table PTAC/UH-43-B— Electric Wall Mounted Unit Heaters without Unit Mounted Thermostat
Order Element
kW No. + Motor Element Ship Amp
Rating UHWA 233-2 Voltage Phase Amps wt. lbs. Rating
021A5A0 n/a 208 1 9.6 9.6
2000W 021B5A0 n/a 240 1 8.3 54 8.3
021C5A0 n/a 277 1 7.2 7.2
031A5A0 n/a 208 1 14.4 14.4
3000W 031B5A0 n/a 240 1 12.5 55 12.5
031C5A0 n/a 277 1 10.8 10.8
041A5A0 n/a 208 1 19.2 19.2
041B5A0 n/a 240 1 16.7 16.7
4000W 041C5A0 n/a 277 1 14.4 55 14.4
043A5A0 n/a 208 3 11.1 11.1
043B5A0 n/a 240 3 9.6 9.6
051A5A0 n/a 208 1 24.0 24.1
051B5A0 n/a 240 1 20.8 20.8
5000W 051C5A0 n/a 277 1 18.0 55 18.1
053A5A0 n/a 208 3 13.9 13.9
053B5A0 n/a 240 3 12.0 12.1
All Sizes 3450 233-450 Wall Box5 11
1. If circuit breaker and/or transformers are required, the Series 50 wall heater must be ordered.
2. Wall box must be ordered.

Table PTAC/UH-43-C— Extension Sleeves


Model No. Order No. Series Unit Description
3420EX343 233-401 20 4½” extension sleeve for full surface mtg
3420EX161 233-403 20 2” extension sleeve for semi-recess mtg
2
3420EX8 233-405 20 1” extension sleeve for semi-recess mtg
3450EX343 233-407 50 4½” extension sleeve for full surface mtg
3450EX161 233-409 50 2” extension sleeve for semi-recess mtg
3450EX82 233-411 50 1” extension sleeve for semi-recess mtg
1. For extending front additional 2” from finished wall. Heater recesses 2¼”.
2. For extending front additional 1” from finished wall. Heater recesses 3¼”. Shipping weight for sleeves is 5 lbs.
3. Must be used when heater can not be fully or semi recessed into the wall.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-43 Effective 1/1/06
Electric Unit Heaters
Control Options (Factory Installed)
Line Voltage Thermostats
Table PTAC/UH-44-A— Control Options Factory Installed
Model No. OrderNo. Series Unit Description
R 233-415 20 + 50 Built-in contactor holding coil same as heater voltage.
R1 233-417 20 + 50 Built-in Contactor 24V Holding Coil
R2 233-419 20 + 50 Built-in Contactor 120V Holding Coil
C 233-425 50 Circuit Breaker (Series 50 only) arranged to be disconnected before
removal of front with line side terminals covered for safe maintenance.
Additional control circuit switch installed if required.
A11 233-427 50 Built-in control transformer (Series 50 only) 24V secondary.
A21 233-429 50 Built-in control transformer (Series 50 only) 120V secondary available
on all three-phase heaters, up to 3 kW on 208V and 240V, single-
phase and up to 4 kW on 277V, single-phase.
1. Contactor must be ordered with transformer.

Table PTAC/UH-44-B— Line Voltage Thermostats (Wall Mounted)


Model No. Order No. Description
TW1481 233-301 DPST 25 Amp 120-240V, 18 Amp 277V for single-phase
TW1461 233-303 DPST 25 Amp 120-240V, 18 Amp 277V,Tamper Resistant for single-phase
TW15122 233-715 DPST 30 Amp 120-240V, 25 Amp 277V, 40-90°F for three-phase
TW147 233-311 SPST 25 Amp 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors
TW145 233-313 SPST 25 Amp 120-240V, 18 Amp 277V, Pilot Duty for use with Remote Contactors,
Tamper Resistant
1. For use with one unit single-phase and more than one unit single-phase. Makes and breaks two poles simultaneously.
2. For use with one unit three-phase only and more than one unit three or single-phase. Do not exceed thermostats rated ampacity. Makes and breaks two poles simultaneously.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-44 information.
Electric Unit Heaters
Wall Heater and Accessories

Table PTAC/UH-45-A—Electric Architectural Forced Air Wall Heater 1


Model No. Order No. Element +Motor Element kW Ship
Watts UHAA2 233- 2 Voltage Phase Rating wt. lbs.
151ETAD -500 120 1
1500 151BTAD -512 240 1 1.5 26
151ATAD -502 208 1
151CTAD -522 277 1 1.5 26
021BTAD -514 240 1
2000 021ATAD -504 208 1 2.0 27
021CTAD -524 277 1 2.0 27
031BTAD -516 240 1
3000 031ATAD -506 208 1 3.0 29
031CTAD -526 277 1 3.0 29
041BTAD -518 240 1
4000 041ATAD -508 208 1 4.0 29
041CTAD -528 277 1 4.0 29
481BTAD -520 240 1
4800 481ATAD -510 208 1 4.8 29
481CTAD -530 277 1 4.8 29
1. 3310 Wall Box is standard part of the Wall Heater.
2. All Wall Heaters shipped as standard with factory installed tamperproof thermostat, fan delay and disconnect switch.

Table PTAC/UH-45-B—Suface Mounting Adapter 1


Model No. Order No. Description
3320 EX 33 233-501 Surface Mounting Adapter
1. Field installed.
2. Order as a separate item.

Table PTAC/UH-45-C—Day/Night Relay 1


Model No. Order No. Description
R 233-505 Day/Night Relay
1. Factory installed only.
2. Order as a separate item.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-45 Effective 1/1/06
Electric Unit Heaters
Electric Wall Fin

Electric Wall Fin - Ordering


Information
1. Electric wall fin units with painted enclosures 4. Enclosure sections only with anodized
are available. Please contact St. Louis aluminum fronts and (or) anodized aluminum
Customer Service for more information. outlet grilles are available on a 12 week ship
2. Electric wall fin units with anodized aluminum cycle.
fronts and (or) anodized aluminum outlet grilles 5. Color selection must be specified in the line
and accessories are available. Please contact item notes of the sales order.
St. Louis Customer Service for more
information. 6. Unit Lengths*

3. Blank enclosure sections only with painted 2 ft.


steel fronts and painted aluminum outlet grilles 3 ft.
are available. Please contact St. Louis 4 ft.
Customer Service for more information. 5 ft.
6 ft.
*Cannot go beyond 10 ft. including extended enclosure.

Table PTAC/UH-46-A—Heater with Electric Element and Enclosure


lbs.
Model No. Dimensions per ft.
DBT 6” High x 3½” dp 4.0
DBF 6” High x 3½” dp 4.0
5/8
CB 4½” High x 2 ” dp 3.0
DBCT 7” High x 5” dp 5.0
DBCF 7” High x 5” dp 5.0
RDBT-PD 5” High x 6” dp 5.0
ASHDB 8” High 7.5
10” High 8.5
12” High 9.5
14” High x 5½” dp 10.5
16” High 11.5
18” High 12.5
20” High 13.5
1. Includes Heating Element, Thermal Overload, Front Panel and Back Panel.
2. Model ASHDB furnished with steel front panels.

Table PTAC/UH-46-B—Maximum Watts/Foot


Model No. Maximum W/ft.
DBT 300
DBF 250
CB 250
DBCT 750
DBCF 500
RDBT-PD 300
ASHDB 500

W/ft. Maximum W/ft.


(Single Element Heaters) (Double Element Heaters) V/ph
125 282 120/single-phase
188 376 208/single-phase
250 500 240/single-phase
93 438 277/single-phase
141 564
282 666
333 750
375 625

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-46 information.
Electric Unit Heaters
Enclosures and Finishes

Table PTAC/UH-47-A—Extended Enclosure


Model No. lg lbs.
230-6080 6” 1.0
230-6081 12” 2.0
230-6082 18” 3.0
230-6083 24” 4.0
230-6084 30” 5.0
230-6085 36” 6.0
230-6086 42” 7.0
230-6087 48” 8.0
230-6088 54” 9.0
230-6089 60” 10.0
1. Extends the Enclosure lg another 6”, 12”, 18”, 24”, 30”, 36”, 42”, 48”, 54” or 60”.
2. Extended Enclosure and Heater furnished as a one piece unit.
3. Manufactured with solid metal grilles.
4. Maximum over all Heater Length with Extended Enclosure is 15 feet for Models (DBT, DBF and CB), 12 feet for Models
(DBCT and RDBT-PD) and 10 feet for Model (ASHDB).

Table PTAC/UH-47-B—Blank Enclosure Sections


lbs.
Model No. Dimensions per ft.
DBT 6” High x 3½” dp 4.0
DBF 6” High x 3½” dp 4.0
5/8
CB 4½” High x 2 ” dp 3.0
DBCT 7” High x 5” dp 5.0
DBCF 7” High x 5” dp 5.0
RDBT-PD 5” High x 6” dp 5.0
ASHDB 8” High 7.5
10” High 8.5
12” High 9.5
14” High x 5½” dp 10.5
16” High 11.5
18” High 12.5
20” High 13.5
1. Manufactured with solid metal grille less the electric heating element.
2. Available in 1 ft. through 10 ft. lengths in 1 ft. increments.
3. Can be modified for use with hydronic heating elements for Models DBT, DBF, DBCT, DBCF and ASHDB only.

Table PTAC/UH-47-C—Finish Selection


Color Ordering Number .
Clear Anodized FSHP-CLEAR
Bronze Anodized FSHP-BRONZE
Black Anodized FSHP-BLACK_ANOD
Ivory, Gray, or Eggshell White FSHBP-E_WHITE
Beige Baked Enamel1 FSHBP-BEIGE
White Baked Enamel FSHBP-WHITE
Brown Baked Enamel FSHP-BROWN
Black Baked Enamel FSHP-BLACK
1. Baked Enamel Color Finish per Electric Wall Fin Color Selection Chart - FIN-S-3.
2. Model ASHDB only cannot have anodized color finish.

Table PTAC/UH-47-D—Finished Back Panels - Optional


Finished Back Panel Ordering Number
Clear Anodized (204R1) FSHP-CLEAR
Bronze Anodized (313R1) FSHP-BRONZE
Black Anodized (313R1) FSHP-BLACK_ANOD
Ivory, Gray, or Eggshell White FSHBP-E_WHITE
Beige Baked Enamel FSHBP-BEIGE
White Baked Enamel FSHBP-WHITE
Brown Baked Enamel FSHP-BROWN
Black Baked Enamel FSHP-BLACK
1. Finished back panels either painted or anodized in the same color as the heater are available for pedestal floor mounted
heaters to be installed in front of windows and in lobbies.

Contact Waco Product Support for more


These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-47 Effective 1/1/06
Electric Unit Heaters
Electric Wall Fin Accessories

Table PTAC/UH-48-A—¼” Wire Mesh - Optional

1
/4” Wire Mesh
1. Factory installed under grille on enclosure or Blank Enclosure Sections and Extended Enclosure Sections with open
grilles.

Table PTAC/UH-48-B—Pedestal Brackets - Optional


Ordering No.
230-6020 ASB PD Pedestals
1. For floor mounting of all Model Heaters. Must be ordered separately.
2. Pedestal brackets are available for floor mounting in lobbies and in front of windows for all models except ASHDB 10”,
12”, 14”, 18” and 20” high heaters. Factory installed to the bottom of the unit for field furnished power wiring to be run
through the center of the pedestal into the bottom of the units junction box for connection to the heater. The knockouts that
are provided in the side and rear of each heaters junction box and the back panel mounting holes for wall mounting of
units are not furnished when pedestals are ordered. 2’ to 6’ heaters require two pedestals, 6’ to 8’ heaters require three
pedestals, 9’ and 10’ heaters require four pedestals.

Table PTAC/UH-48-C—Factory Built-In Controls - Optional


Ordering No. Model No. Description
230-6000 ITS Single PoleThermostat 20A 120-277 Vac1
230-6002 ITD Double PoleThermostat 20A 120-277 Vac1
230-6005 IDS Double Pole Disconnect Switch 20A 120-277 Vac2
230-6010 ATR Transformer Relay single pole 25A 120-277 Vac3
230-6012 PR Power Relay Contactor 208/24, 208/208 18 amp4, 5
230-6014 PR Power Relay Contactor 240/24 18 amp4, 5
230-6016 PR Power Relay Contactor 277/24, 277/277 18 amp4, 5
1. Factory mounted and wired in left hand junction box, adjustable thru discharge grille.
2. Factory mounted and wired in left hand junction box, adjustable thru discharge grille.
3. Rated 25 Amp 120-277 VAC contacts rated up thru 277V and must be specified. Coils are 24V and 120V and must be specified. Requires 6” or 12” Control Sections for mounting which
will lengthen the heater dimensions. 12” Extended Enclosures must be used.
4. Requires 6” or 12” Control Sections for mounting which will lengthen the heater dimensions. 12” Extended Enclosures must be used.
5. Standard Contactor with 18 Amp contacts and coil voltage of 24V or same as primary voltage of the heater as specified.

TTable PTAC/UH-48-D—Control Sections


Ordering No. Model No. Description
230-6030 CS6 6” Control Section1
230-6033 CS12 12” Control Section2
1. For factory mounting of 1 or 2 controls. Right or left side mounting available with right side being standard. Requires 12” Extended Enclosure for installation. Control Sections must be field
wired to the heater.
2. For factory mounting of 1, 2 or 3 controls. Right or left side mounting available with right side being standard. Requires 12” Extended Enclosure for installation. Control Sections must be
field wired to the heater.

Table PTAC/UH-48-E—Inside Corners


Model No. Ordering No.
DBT-IC
DBF-IC 230-6040
CB-IC
DBCT-IC 230-6044
DBCF-IC
RDBT-PD-IC 230-6046
ASHDB-IC 8”-20” 230-6048
1. Inside Corners 90 - 180° furnished as standard.

Table PTAC/UH-48-F—Outside Corners


Model No. Ordering No.
DBT-OC
DBF-OC 230-6050
CB-OC
DBCT-OC 230-6054
DBCF-OC
RDBT-PD-OC 230-6056
ASHDB-OC 8”-20” 230-6058
1. Outside Corners 180 - 270° furnished as standard.

Contact Waco Product Support for more


information on these products (1-888-872-6335) These items are not available to all distribution channels.
Please contact your distributor or local sales office for more
Effective 1/1/06 PTAC/UH-48 information.
Electric Unit Heaters
Electric Wall Fin Accessories

Table PTAC/UH-49-A—LH and RH End Caps


Model No. Ordering No.
DBT-EC
DBF-EC LH - 230-6051
CB-EC RH - 230-6055
DBCT-EC
DBCF-EC
ASHDB-EC LH - 230-6053
RH - 230-6059
RDBT-EC LH-PDIEC
RDBT-EL RH-PDIEC
1. Specify Left or Right hand.
2. To cap off each end of the heater for a finished look.

Table PTAC/UH-49-B—2” Wall Trims


Model No. Ordering No.
DBT-WT_
DBF-WT_ 230-6062
CB-WT_
DBCT-WT_ 230-6063
DBCF-WT_
ASHDB-WT_ 230-6065
1. Extends the end of the heater to the wall or column.

Table PTAC/UH-49-C—6” Wall Trims


Model No. Ordering No.
DBT-WT_
DBF-WT_ 230-6061
CB-WT_
DBCT-WT_ 230-6067
DBCF-WT_
ASHDB-WT_ 230-6068
1. Extends the end of the heater to the wall or column.

Table PTAC/UH-49-D—1½” Splice Plate


Model No. Ordering No.
DBT-SP
DBF-SP 230-6060
CB-SP
DBCT-SP 230-6064
DBCF-SP
ASHDB-SP 230-6066
1. Conceals gap between two heaters or blank sections.

Table PTAC/UH-49-E—Accessories for Mounting Hydronic Heating Elements


Item Ordering No.
Rod Hangers 230-6070
Slide Cradle Brackets 230-6071
6” Valve Compartment Blank Sections 230-6072
12” Valve Compartment Blank Sections 230-6074
1. Order qty. 2 Rod Hangers or Slide Cradle Brackets for 2' - 5' lengths, qty. 3 for 6' - 8' lengths and qty. 4 for 9' - 10' lengths.

Table PTAC/UH-49-F—Wall Mounted Controls — Optional


Model No. Order No. Description
TW241 230-006 SPST Wall Mounted Line VoltageThermostat, 40-90°F, 250 VA2
TW242 230-007 DPST Wall Mounted Line VoltageThermostat, 40-90°F, 250 VA2
MB-120 230-009 Wall Mounted Low VoltageThermostat, 50-90°F, 24V
A62811 233-370 Remote MountedThermal Relay with Built-In Line Voltage/24V
Transformer. 120, 208, 240 or 277V SPST 25 Amp
1. Specify voltage on the sales order.
2. Electrical rating and W — 120V - 2600W, 208V - 4500W, 240V - 5200W and 277V - 4900W.
Contact Waco Product Support for more
These items are not available to all distribution channels. information on these products (1-888-872-6335)
Please contact your distributor or local sales office for more
information. PTAC/UH-49 Effective 1/1/06
Extended Warranty Labor Options

Labor Options provide more flexibility for

IF APPLICABLE
PROMO STAMP
Dealer/Seller Servicer (if other than Dealer/Seller)

the dealer and are selected at the time of Dealer/Seller # Servicer #


sale. These options determine how long Name ____________________________________ Name ____________________________________
a dealer has to guarantee his labor, and Address __________________________________ Address __________________________________
establish the set of “Servicer Guideline” City, State, Zip ____________________________ City, State, Zip ____________________________
rates that can be used when making UNITARY
PRODUCTS GROUP
Telephone # ( ______ ) _____________________ Telephone # ( ______ ) _____________________
claims. The options are as follows: For Extended Warranty Dept. Use Only Completed by Distributor Only

Labor Option #1: Agreement No. __________________________________ Bill to #

Trane’s Optional Extended Warranty is Rec’d. Date: __________________________________ Name ______________________________________________

responsible for labor beginning the Approved By _______________________________________


Purchasers P.O. # ____________________________________
ninety-first (91st) day from the date (If Desired)

of installation or the date activated,


whichever is later. The dealer is respon- EXTENDED WARRANTY APPLICATION
sible for the labor through the first ninety
(90) days.
Warranty Model # T A Y WA R *Not used on some
warranty model numbers.

Servicer Labor Option: 1 2 3 (Circle One)


Labor Option #2: Is this warranty a renewal of an existing Extended Warranty? Yes No
Trane’s Optional Extended Warranty is If yes, what is the agreement number of the old warranty .
Product Application: ■ Residential ■ Commercial
responsible for labor beginning one (1) Equipment Covered: ■ System ■ Condensing Unit ■ Furnace/Air Handler ■ Compressor Only ■ Other ______________
year from the date of installation. The Length of Coverage: ■ 1 Year ■ 5 Years ■ 10 Years ■ 15 Years ■ 20 Years
Type of Coverage: ■ Parts Only ■ Labor Only ■ Both Parts and Labor
dealer is responsible for the labor Note: Not all combinations of above are available. The warranty model number listed above must agree with selections.

through the first (1st) year. Labor Option EQUIPMENT OWNER: (Mailing Address) EQUIPMENT LOCATION: (If Different)
#2 is not available on equipment over 9
Name Name
months old or on "Parts Only" Optional Address Address
Extended Warranties. City State Zip (Required) City State Zip (Required)

Labor Option #3: (


Telephone
)

Trane’s Optional Extended Warranty is EQUIPMENT


COVERED
Note: Use separate applications for each required agreement.
MODEL # – use 1st 11 digits SERIAL # Date Equipment Installed ___________________
responsible for labor beginning the ___________________ _________________________ __________________________
Required

ninety-first (91st) day from the date of ___________________ _________________________ __________________________ Date Warranty Sold ___________________
By Dealer
installation or the date activated, ___________________ _________________________ __________________________

whichever is later. The dealer is respon- ___________________ _________________________ __________________________ Warranty Sales Price $ __________________

sible for labor through the first ninety If the Equipment Covered is a Compressor Only – What is the Condensing Unit Model # ___________________________________
(90) days. What is the Condensing Unit Serial # ___________________________________

Coverage for Labor Option #3 will cost This Document is an Application Only. The Extended Warranty will become effective when accepted by
The Trane Company. The Trane Company will notify the Equipment Owner by sending the Extended Warranty
more than the other two options. If it Agreement that provides coverage for the Extended Warranty Model listed above. If you do not receive a
confirming agreement from Trane within 45 days, please call 800-554-6413.
is chosen, the Trane Optional Extended
As the Equipment Owner, I acknowledge that I have
Warranty Agreement will automatically read and understand the “Terms and Conditions” as well
Dealer/Seller’s Signature* Date as the type of coverage and length of coverage of the
be assigned the letter “X” to the end of Trane Extended Warranty for which I have applied.

the model number. (Example: DEALER INSTRUCTIONS: Send To Your Distributor For Processing.
Equipment Owner’s Signature Date
TAYWAR0004 that contains Labor * Dealer/Seller’s signature indicates equipment over 9 months old has been inspected and is in good working condition.
Option #3 will become TAYWAR0004X). Inspection not required if equipment is less than 9 months old or if this is a renewal of an existing extended warranty.
Pub. No. 26-1021-06 (12/00)
To determine the exact cost of an Trane or latest version
Optional Extended Warranty that
contains Labor Option #3, refer to the
price book and select the model number
that contains the letter “X” Labor options are chosen at the time an application is completed using the three
at the end of the model number. It is not (3) selection blocks on the application form (see above). The dealer simply marks
necessary to indicate the the option chosen. When the application is activated, that agreement will always be
“X” in the model number when associated with that Labor Option. If no option is chosen, then option #1 will
completing an application. automatically be selected.
The “Servicer Guideline Rates” for Refer to the Trane Optional Extended Warranty Handbook for additional information
labor options #1, #2, and #3 are (Pub. No. 26-1019).
used when submitted claims and
are noted on page WA-2 and WA-3.
Great care has been taken to ensure the accuracy of the information in the Extended Warranty
section of the Residential and Light Commercial Products Handbook; however, the information in
the Trane Optional Extended Warranty handbook supersedes all information contained herein.

WA-1 Effective 1/1/06


Trane Optional Extended Warranty
“Standard Servicer Guidelines”
These guidelines should be used when submitting claims on “Trane Extended Warranty” agreements - Standard or Labor Option #1.
1. ALLOWABLE LABOR RATES ———————— Dealer’s standard hourly rate.
2. PARTS MARK UP ALLOWANCE (Used for out-of-warranty parts)
$0.01 - 4.99 = Dealer Cost + $5.00
$5.00 - 24.99 = Dealer Cost x 2.0
$25.00 - 49.99 = Dealer Cost x 1.7
$50.00 - 149.99 = Dealer Cost x 1.6
$150.00 - 499.99 = Dealer Cost x 1.5
$500.00 - up = Dealer Cost x 1.4
Refrigerant = Dealer Cost x 2.0
IN-WARRANTY PARTS MARK UP ALLOWANCE (Used for in-Warranty Parts, years 2-5 when equipment has 5-year parts Manufacturer’s Limited Warranty. Does not apply to
compressor, outdoor coil, or heat exchanger. If a non-Trane part is purchased during the Manufacturer’s Limited Warranty period, dealer will be reimbursed cost of part only,
maximum $10.00)
Labor Option #1
$0.01 - 4.99 = Dealer’s Normal Purchase Price, $5.00
$5.00 - 24.99 = Dealer’s Normal Purchase Price x 1.0
$25.00 - 49.99 = Dealer’s Normal Purchase Price x 0.7
$50.00 - 149.99 = Dealer’s Normal Purchase Price x 0.6
$150.00 - 499.99 = Dealer’s Normal Purchase Price x 0.5
$500.00 - up = Dealer’s Normal Purchase Price x 0.4
3. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is less
than the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, each
additional component may receive a maximum of 0.5 hours. For any component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time is
greater than the amounts specified below, or as described in this paragraph, and you believe that additional time is justified, please explain the circumstances of the repair or
replacement in writing.

Max Hours Allowed


Replacement or Repaired Item 1-5 Tons 6 1/4 - 25 Tons
Refrigerant Circuit2
Refrigerant recovery (only if required) .................................................................... 1.0 2.0
Compressor replacement3 .................................................................................... 4.0 6.0
Condenser coil replacement ................................................................................... 4.0 6.0
Evaporator coil replacement ................................................................................... 4.5 6.0
Expansion valve replacement ................................................................................ 3.0 4.0
Switch over valve replacement ............................................................................... 3.5 4.5
Check valve replacement or service valve ............................................................. 2.0 3.0
Drier replacement ................................................................................................... 1.0 1.0
Schrader core ......................................................................................................... 0.5 0.5
Tighten valves (caps, cores, rotolocks) .................................................................. 0.5 0.5
Repairable leak in fitting, etc. (Brazing required,explain work done) ......................... 2.0 3.0
Electrical Controls
Any component replacement .................................................................................. 0.5 0.5
Hard start kit ........................................................................................................... 0.5 —
Thermostat (Indoor) ................................................................................................ 1.0 1.0
Thermostat (Outdoor) ............................................................................................. 0.5 0.5
Crankcase heater replacement .............................................................................. 0.5 0.5
Condenser Fan Assemblies
Fan blade replacement ........................................................................................... 0.5 0.5
Motor replacement (includes fan blade, capacitor) ................................................ 1.5 1.5
Evaporator Fan Assembly
Blower wheel replacement ..................................................................................... 1.0 1.0
Motor replacement (includes blower wheel, capacitor) .......................................... 1.5 1.5
Replace module (includes motor) ........................................................................... 1.0 1.0
Bearing replacement - each ................................................................................... 0.5 0.5
Sheaves replacement - each (includes belt) .......................................................... 0.5 0.5
Belt replacement ..................................................................................................... 0.5 0.5
Drain pan replacement ........................................................................................... 2.0 2.0
Heating Section
Any control replacement (ignitor, sensor, ignition control, etc.) ............................. 0.5 0.5
Heating element replacement ................................................................................ 1.0 1.0
Combustion blower replacement ............................................................................ 1.0 1.0
Gas valve replacement ........................................................................................... 1.0 1.0
Heat exchanger replacement ................................................................................. 4.0 6.0
Burners ................................................................................................................... 1.0 1.0
Economizer Section
Any control replacement ......................................................................................... 0.5 0.5
Actuator replacement ............................................................................................. 1.0 1.0 Great care has been taken to ensure the accuracy of
Misc. Section the information in the Extended Warranty section of
Solve noise complaint7 ......................................................................................... 0.5 0.5 the Residential and Light Commercial Products
Diagnostic Charge1 ............................................................................................... 0.5 0.5 Handbook; however, the information in the Trane
Multiple Components .............................................................................................. 0.5 0.5 Optional Extended Warranty handbook supersedes
NOTES: all information contained herein.
1 Diagnostic calls will be paid only on covered repairs. (Not paid on maintenance or dirty sock)
2 All times allowed requiring entry or repair to refrigerant circuit includes evacuation, recharge and drier change.
3 All times allowed for compressor replacement includes drier change, cleanup, evacuation and recharge.
4 Crane allowance up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of crane charge is allowed on systems applied in a commercial application or if the equipment is 4
tons or greater. (Not allowed on parts only warranty.)
5 Sales tax, if applicable, will be reimbursed to the dealer.
6 All times not shown for specific tasks - Call 1-800-554-6413.
7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hrs. plus the time allowed for the component
replacement/repair. Explain fully.
8 Pay only one (1) man per job.
9 All invoices must be received within sixty (60) days of the repair.

TRAVEL TIME: (Flat Rate Dealers cannot charge Travel Time)


24 miles or less, one way - add 1/2 hour based on your established labor rate.
25 miles or greater, one way - add 1 hour based on your established labor rate.
Only one (1) trip charge paid per service call.
ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.
Effective 1/1/06 WA-2
Trane Optional Extended Warranty
“Expanded Servicer Guidelines”
These guidelines should be used when submitting claims on “Trane Optional Extended Warranty” Agreements - Labor Option #2 & #3.
1. ALLOWABLE LABOR RATES ———————— Dealer’s standard hourly rate.
2. PARTS MARK UP ALLOWANCE (Used for out-of-warranty parts)
$0.01 - 4.99 = Dealer Cost + $7.50
$5.00 - 24.99 = Dealer Cost x 2.5
$25.00 - 49.99 = Dealer Cost x 2.1
$50.00 - 149.99 = Dealer Cost x 1.9
$150.00 - 499.99 = Dealer Cost x 1.7
$500.00 - up = Dealer Cost x 1.5
Refrigerant = Dealer Cost x 2.0
IN-WARRANTY PARTS MARK UP ALLOWANCE (Used for in-Warranty Parts, years 2-5 when equipment has 5 year parts Manufacturer’s Limited Warranty. Does not apply to
compressor, outdoor coil, or heat exchanger. If a non-Trane part is purchased during the Manufacturer’s Limited Warranty period, dealer will be reimbursed cost of part only,
maximum $10.00)
Labor Option #2 and #3
$0.01 - 4.99 = Dealer’s Normal Purchase Price, $7.50
$5.00 - 24.99 = Dealer’s Normal Purchase Price x 1.5
$25.00 - 49.99 = Dealer’s Normal Purchase Price x 1.1
$50.00 - 149.99 = Dealer’s Normal Purchase Price x 0.9
$150.00 - 499.99 = Dealer’s Normal Purchase Price x 0.7
$500.00 - up = Dealer’s Normal Purchase Price x 0.5

3. REPAIR/REPLACE TIME — The hours provided below constitute the maximum number of hours that may be claimed. If your actual repair or replacement time is less
than the amounts specified below, or as described in this paragrah, your actual time must be reported. For multiple component replacements in the same unit, each
additional component may receive a maximum of 0.5 hours. For any component not listed, it may receive a maximum of 0.5 hours. If your actual repair or replacement time is
greater than the amounts specified below, or as described in this paragraph, and you believe that additional time is justified, please explain the circumstances of the repair or
replacement in writing.
Max Hours Allowed
Replacement or Repaired Item 1-5 Tons 6 1/4 - 25 Tons
Refrigerant Circuit2
Refrigerant recovery (only if required) ........................................................................... 1.0 2.0
Compressor replacement3 ........................................................................................... 4.0 6.0
Condenser coil replacement .......................................................................................... 4.0 6.0
Evaporator coil replacement .......................................................................................... 4.5 6.0
Expansion valve replacement ........................................................................................ 3.0 4.0
Switch over valve replacement ...................................................................................... 3.5 4.5
Check valve replacement or service valve ..................................................................... 2.0 3.0
Drier replacement .......................................................................................................... 1.0 1.0
Schrader core ................................................................................................................ 0.5 0.5
Tighten valves (caps, cores, rotolocks) .......................................................................... 0.5 0.5
Repairable leak in fitting, etc. (brazing required explain work done) ............................. 2.0 3.0
Electrical Controls
Any component replacement ......................................................................................... 0.5 0.5
Hard start kit ................................................................................................................... 0.5 —
Thermostat (Indoor) ....................................................................................................... 1.0 1.0
Thermostat (Outdoor) .................................................................................................... 0.5 0.5
Crankcase heater replacement ...................................................................................... 0.5 0.5
Condenser Fan Assemblies
Fan blade replacement .................................................................................................. 0.5 0.5
Motor replacement (includes fan blade capacitor) ......................................................... 1.5 1.5
Evaporator Fan Assembly
Blower wheel replacement ............................................................................................. 1.0 1.0
Motor replacement (includes blower wheel, capacitor) .................................................. 1.5 1.5
Module replacement (includes motor) ............................................................................ 1.0 1.0
Bearing replacement - each ........................................................................................... 0.5 0.5
Sheaves replacement - each (includes belt) .................................................................. 0.5 0.5
Belt replacement ............................................................................................................ 0.5 0.5
Drain pan replacement ................................................................................................... 2.0 2.0
Heating Section
Any control replacement (ignitor, sensor, ignition control, etc.) .................................... 0.5 0.5
Heating element replacement ........................................................................................ 1.0 1.0
Combustion blower replacement ................................................................................... 1.0 1.0
Gas valve replacement .................................................................................................. 1.0 1.0
Heat exchanger replacement ......................................................................................... 4.0 6.0
Burners .......................................................................................................................... 1.0 1.0
Economizer Section Great care has been taken to ensure the accuracy of
Any control replacement ................................................................................................ 0.5 0.5 the information in the Extended Warranty section of
Actuator replacement ..................................................................................................... 1.0 1.0 the Residential and Light Commercial Products
Misc. Section Handbook; however, the information in the Trane
Solve noise complaint7 ................................................................................................ 0.5 0.5 Optional Extended Warranty handbook supersedes
Diagnostic Charge1 ...................................................................................................... 0.5 0.5 all information contained herein.
Multiple Components ..................................................................................................... 0.5 0.5
NOTES: 1 Diagnostic calls will be paid only on covered repairs. (Not paid on maintenance or dirty sock)
2 All times allowed requiring entry or repair to refrigerant circuit includes evacuation, recharge and drier change.
3 All times allowed for compressor replacement includes drier change, cleanup, evacuation and recharge.
4 Crane allowance up to $150 or 2 hrs. at a Dealer’s registered rate in lieu of crane charge is allowed on systems applied in a commercial application or if the
equipment is 4 tons or greater. (Not allowed on parts only warranty.)
5 Sales tax, if applicable, will be reimbursed to the dealer.
6 All times not shown for specific tasks - Call 1-800-554-6413.
7 Noise complaint paid only when noise due to internal component failure or malfunction. Maximum time allowed is 0.5 hours plus the time
allowed for the component replacement/repair. Explain fully.
8 Pay only one (1) man per job.
9 All invoices must be received within sixty (60) days of the repair.
TRAVEL TIME (Flat Rate Dealers cannot charge Travel Time):
Mileage (any distance) - add 1 hour based on your established labor rate.
Two (2) trip charges are allowed for major component replacement (compressor, outdoor coil, evaporator coil, switch over valve, burners, or heat exchanger).
ALL CLAIMS RELATED DECISIONS MADE BY AMERICAN STANDARD WARRANTY COMPANY ARE FINAL.

WA-3 Effective 1/1/06


Optional Extended Warranty Benefits

Consumer Benefits
Peace of Mind
• No unexpected out-of-pocket expenses*
• Repair/Replace option allows consumer to apply repair cost toward
purchase price of new equipment
• Hedge against inflation (parts, labor and refrigerant)

Assurance of Commitment
• Trane dealer assigned to their agreement has up-to-date
knowledge of equipment and service techniques
• Extended Warranty is transferrable to subsequent homeowners
should the original owner sell their home
• Cost effective as compared to other Extended Warranties
(i.e., appliances, consumer electronics, automobiles)

Dealer Benefits
• Labor Coverage after 90th Day (lower labor reserves)
• Extended Warranty contracts assign selling dealer as servicer of
record which potentially “locks in” customer for the life of the
warranty
• Provides “In Warranty” parts markup (revenue opportunity)
• Additional profit opportunity by selling the Extended Warranty
(gross profit becomes close to net profit)
• Repair/Replace option allows consumer to apply repair costs
toward purchase price of new equipment
• Dealer provides more comprehensive coverage which improves
customer satisfaction with dealer and Trane
• Encourages the sale of Maintenance Agreements
• Commercial Product up to 25 tons can be covered up to 10 years
for parts and labor
• New construction dealer can include Extended Warranties, captur-
ing customers they normally don’t see (if agreement is put in the
builder’s name, the agreement can be transferred to the new
homeowner at no charge)

Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of the Residential and Light
Commercial Products Handbook; however, the information in the Trane Optional Extended Warranty handbook supersedes all
information contained herein.

*Covers labor, refrigerant, diagnostic, and parts, subject to product coverage and terms and conditions.

Effective 1/1/06 WA-4


Optional Extended Warranty Benefits

Example:
Assumptions:
• Unit is 4 years old and an Evaporator Coil must be replaced
• Evaporator Coil is an in-warranty part that would normally cost $500
if purchased
• Dealer has $70/hr. labor rate (time and material, not flat rate)
• 7 lbs. of R410A needed for repair (dealer cost is $11/lb.)

Consumer has No
Consumer has 10-Yr. P&L, Lbr. Opt. 3 Extended Warranty Difference
EW Pays Dealer Consumer Pays Dealer
Labor Travel (2 hrs.) $ 140.00 $ 140.00 $ -
Diagnostic (.5 hrs.) $ 35.00 $ 35.00 $ -
Repair (4.5 hrs.) $ 315.00 $ 315.00 $ -
Total $ 490.00 $ 490.00 $ -

Parts Coil (.5 x normal cost) $ 250.00 $ - (in-warranty part) $ 250.00


R410A
(2 x #lbs. x dealer cost) $ 154.00 $ 154.00 $ -

Total $ 894.00 $ 644.00 $ 250.00


Profit on Parts $ 327.00 $ 77.00 $ 250.00

• In the above example, even with a 10-year Limited Warranty on parts, the consumer still paid $644 for a
coil replacement, and you made only $77 in profit on parts. With the Extended Warranty, the consumer
pays nothing for the repair and you made an additional $250 in profit on parts

Selling Story:
• The Extended Warranty should be offered at time of sale (can be
included with financing)
• Use the Extended Warranty Sales Brochure, Pub. No. 26-1016 and the
consumer benefits on the reverse side
• Point out that Limited Warranty does not cover refrigerant or labor
• If the Extended Warranty is “included” in the total proposal, it is much easier
to sell
• If you are in a “regulated” state, you must provide the actual purchase price
(not to be less than your actual cost) on the Extended Warranty Application.
This amount will appear on the consumer’s agreement (see your Extended
Warranty Handbook for more information on selling Extended Warranties in
“regulated” states)

Great care has been taken to ensure the accuracy of the information in the Extended Warranty section of
the Residential and Light Commercial Products Handbook; however, the information in the Trane Optional
Extended Warranty handbook supersedes all information contained herein.

WA-5 Effective 1/1/06


Roof Curbs

BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB OUTLINE

018 through 036

Full Perimeter BAYCURB050A Full Perimeter BAYCURB051A


4TCC3018-036A 4TCC3042-060A
4TCX3018-036A 4TCX3042-060A
2/4WCC3018-036A 2/4WCC3042-060A
2/4WCX3018-036A 2/4WCX3042-060A
2/4YCC3018-036A 2/4YCC3042-060A
2/4YCX3018-036A 2/4YCX3042-060A

BAYCURB051A FULL PERIMETER ROOF MOUNTING CURB OUTLINE

042 through 060

For complete equipment / combination


selections and installation instructions, please AC/IN-1 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Roofcurb Adaptors

BAYADAP050A CURB ADAPTOR FOR ***018-36A TO EXISTING BAYCURB030 OR BAYCURB038

*All 15 digit model numbers starting with 2 or 4 and


YCC, YCX, TCC, TCX, WCC and WCX. EXISTING NEW UNIT USE
CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54

For complete equipment / combination


Effective 1/1/06 AC/IN-2 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Roofcurb Adaptors

BAYADAP051A CURB ADAPTOR FOR ***018-36A TO EXISTING BAYCURB033

*All 15 digit model numbers starting with 2 or 4 and EXISTING NEW UNIT USE
YCC, YCX, TCC, TCX, WCC and WCX.
CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54

For complete equipment / combination


selections and installation instructions, please AC/IN-3 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Roofcurb Adaptors

BAYADAP052A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB030 OR BAYCURB038

EXISTING NEW UNIT USE


*All 15 digit model numbers starting with 2 or 4 and
YCC, YCX, TCC, TCX, WCC and WCX. CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54

For complete equipment / combination


Effective 1/1/06 AC/IN-4 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Roofcurb Adaptors

BAYADAP053A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB030 OR BAYCURB033

56 1/8"
53 1/8" I.D.
19 1/2" I.D. 28 7/8" I.D.

10"
Weight in Lbs.
Shipping
61 21/32" Weight
155
41 7/8"
56 1/8" Operating
110
EXISTING Weight

CURB

SA

ROOF
VIEW “A”-”A” RA

EXISTING CURB
BAYCURB033

41 7/8"
38 7/8" I.D.

20" I.D.
“A” 57 21/32"
31"
“B”

35" “B”
“A”
EXISTING
CURB

ROOF
VIEW “B”-”B”
*All 15CC
digit C
modelCC C
numbers CC
starting withC2 or 4 and EXISTING NEW UNIT USE
YCC, YCX, TCC, TCX, WCC and WCX. CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54

For complete equipment / combination


selections and installation instructions, please AC/IN-5 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Roofcurb Adaptors

BAYADAP054A CURB ADAPTOR FOR *****042-60A TO EXISTING BAYCURB034

*All 15 digit model numbers starting with 2 or 4 and EXISTING NEW UNIT USE
YCC, YCX, TCC, TCX, WCC and WCX. CURB 2/4TC/WC/YC****A BAYADAP0**A
BAYCURB030,38A 018-036 50
BAYCURB030,38A 042-060 52
BAYCURB033A 018-036 51
BAYCURB033A 042-060 53
BAYCURB034A 042-060 54

For complete equipment / combination


Effective 1/1/06 AC/IN-6 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Impack™ Roof Curbs

BAYCURB030A UNIVERSAL ROOF MOUNTING CURB OUTLINE

Universal curb w/adaptations, fits all Impack models

Full Perimeter BAYCURB030A Full Perimeter BAYCURB038A


TCC018-042 WCC018-042 YCC018-036M TCC018-042 WCC018-042 YCC018-036M
TCP024-030 WCX024-030 YCP024-36M TCP024-030 WCX024-030 YCP024-36M
TCX024-030 WCY024-030 YCX024-036M TCX024-030 WCY024-030 YCX024-036M
TCY024-030 TCY024-030

BAYCURB038A UNIVERSAL ROOF MOUNTING CURB OUTLINE

Insul.
Deck

Universal curb w/adaptations,


fits all Impack models with insulated deck pans
From Dwg. 21C662034 Rev. 2

For complete equipment / combination


selections and installation instructions, please AC/IN-7 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Impack™ Roof Curbs

BAYCURB033A ROOF MOUNTING CURB OUTLINE

Full perimeter fit curb for Impack models with insulated deck pan

Full Perimeter BAYCURB033A Full Perimeter BAYCURB034A


TCP036-042F WCP036 YCC036H,042 TCC048-060 WCC048-060 YCC048H-060
048M
TCX036-042G WCX036-042G YCP036H-042 TCP048-060 WCP048-060 YCP048-060
TCY036-042G WCY036-042G YCX036H-042 TCX048-060 WCX048-060G YCX048-060
TCY048-060G WCZ036 YCY024-042 WCY048-060G YCY048-060
YCZ036F WCZ060F YCZ050, 060F

BAYCURB034A ROOF MOUNTING CURB OUTLINE


SUPPLY /RETURN AIR DUCT OPENINGS

Full perimeter fit curb for Impack models with insulated deck pan
From Dwg. 21C662034 Rev. 2

For complete equipment / combination


Effective 1/1/06 AC/IN-8 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Thermal Expansion Valves

Table AC/IN-9-A Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
R-410 R-22 Used With
Model Number Model Numbers 13 SEER Coils
4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXC,CXC,CXA -018
4AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -024
4AYTXVH3D1831A 2AYTXVH3C2425A 2/4TXC,CXC,CXA -025
4AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -030
4AYTXVH3D1831A 2AYTXVH3C3031A 2/4TXC,CXC,CXA -031
4AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -036
4AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXC,CXC,CXA -037
4AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -042
Expansion Valve TXV 4AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXC,CXC,CXA -043
Cooling/Heat Pump Kit 4AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -048
4AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -049
General Information 4AYTXVH3D4863A 2AYTXVH3C4850A 2/4TXC,CXC,CXA -050
This Thermostatic Expansion Valve Kit may 4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -060
be used on any indoor air handler or coil that 4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXC,CXC,CXA -061
is equipped with a current thermostatic
expansion valve with an internal check valve Table AC/IN-9-B Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
and mechanical fittings This kit can be used R-410 R-22 Used With
Model Number Model Number Horizontal Flat Coils
on split system heat pumps and air condi-
4AYTXVH3D1831A 2AYTXVH3C1818A 2/4TXF -018
tioning systems.
4AYTXVH3D3343A 2AYTXVH3C3337A 2/4TXF -033
4AYTXVH3D3343A 2AYTXVH3C4243A 2/4TXF -041
Thermostatic Expansion Valve Kits can be
4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -054
field installed to fit a variety of sizes and
4AYTXVH3D4863A 2AYTXVH3C5463A 2/4TXF -063
combinations of air handlers or coils and
outdoor units to optimize performance. Table AC/IN-9-C Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
R-410 R-22 Used With
This TXV kit will normally be used when a Model Model High Efficiency
different refrigerant is going to be used in the Number Number Aluminum Coils
air handler or coil than what is indicated on 4AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -025
the unit name plate. The TXV type must al- 4AYTXVH3B2531A 2AYTXVH3B2531A 2/4TXC -031
ways match the refrigerant type used in the 4AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -036
outdoor unit. 4AYTXVH3B3654A 2AYTXVH3B3637A 2/4TXC -037
4AYTXVH3B3654A 2AYTXVH3B5454A 2/4TXC -054
Kit Identification 4AYTXVH3B6165A 2AYTXVH3B6161A 2/4TXC -061
The first character in the kit model number 4AYTXVH3B6165A 2AYTXVH3B6565A 2/4TXC -065
indicates the type of refrigerant that the
valve can be used with. Example a Table AC/IN-9-D Cooling/ Heat Pump Non-Bleed TXV Kits- Dual Direction Flow
2AYTXVH3D1830A is an R-22 valve. R-410 R-22 Used With
Number Numbers Air Handlers
The “3” in the eighth digit in the model 4AYTXVH3D1831A 2AYTXVH3D1830A 2TFB -018-030
number identifies the valve as a non-bleed 4AYTXVH3D1831A 2AYTXVH3D1830A 2/4TFE -025
TXV. When this TXV kit is installed with an
outdoor unit that contains a reciprocating 4AYTXVH3D1831A 2AYTXVH3D1830A 2/4TEC -018-030
compressor, the outdoor unit must be — 2AYTXVH3D3636A 2/4TEC -036
equipped with a hard start kit if not factory 4AYTXVH3D3642A — 2/4TEC -036-042
installed. If the outdoor unit contains a scroll — 2AYTXVH3D4260A 2/4TEC -042-060
compressor, the installation of a hard start 4AYTXVH3D4863A — 2/4TEC -048-060
kit may be required.
4AYTXVH3D1831A 2AYTXVH3D1830A 2TEH -018-030
Inspection — 2AYTXVH3D3636A 2TEH -036
Check carefully for any shipping damage. 4AYTXVH3D3642A — 2TEH -036-042
Any such damage must be reported and — 2AYTXVH3D4260A 2TEH -042-060
claims made against the transportation 4AYTXVH3D4863A — 2TEH -048-060
company immediately. Any missing parts
should be reported to your supplier at once 4AYTXVH3D1831A 2AYTXVH3D1830A 2TGB -018-036
and replaced with authorized parts only. 4AYTXVH3D3642A — 2TGB -042
— 2AYTXVH3D4260A 2TGB -042-048
4AYTXVH3D4863A — 2TGB -048

For complete equipment / combination


selections and installation instructions, please AC/IN-9 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Thermal Expansion Valves

Table AC/IN-10-A — Cooling Bleed TXV Kits – Single Direction Flow


Liquid Line Gas Line
Model Used With Connection Connection Shipping
Number AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant
1 1 5
TAYTXVA0B5C 1-1 /2 Ton /4 /8 2 R-22
TAYTXVA0C5C 2-21/2 Ton 5
/16 3
/4 2 R-22
TAYTXVA0E5C
TAYTXVA0G5C
3-31/2 Ton
4 Ton
PHASED OUT
3
3
/8
/8
7
/8
11/8
2
2
R-22
R-22
3 1
TAYTXVA0H5C 5-6 Ton /8 1 /8 2 R-22

Table AC/IN-10-B — Cooling Non-Bleed TXV Kits – Single Direction Flow


Expansion Valve TXV Liquid Line Gas Line
Cooling Kit Model Used With Connection Connection Shipping
Number AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant
TAYTXVA0B3C 1-11/2 Ton 1
/4 5
/8 2 R-22
2-21/2 Ton 5 3
TAYTXVA0C3C
TAYTXVA0E3C
TAYTXVA0G3C
3-31/2 Ton
4 Ton
PHASED OUT
3
3
/16
/8
/8
7
/4
/8
11/8
2
2
2
R-22
R-22
R-22
3
TAYTXVA0H3C 5-6 Ton /8 11/8 2 R-22

Table AC/IN-10-C — Heat Pump Non- Bleed TXV Kits (also for cooling) – Dual Direction Flow
Liquid Line Gas Line
Model Used With Connection Connection Shipping
Number AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant
TAYTXVH0B3C 1-11/2 Ton 1
/4 5
/8 3 R-22
2-21/2 Ton 5 3
TAYTXVH0C3C
TAYTXVH0E3C
TAYTXVH0G3C
3-31/2 Ton
4 Ton
PHASED OUT
3
3
/16
/8
/8
7
1
/4
/8
1 /8
3
3
3
R-22
R-22
R-22
3
TAYTXVH0H3C 5-6 Ton /8 11/8 3 R-22

Table AC/IN-10-D— Cooling/Heat Pump Non-Bleed TXV Kits - Dual Direction Flow*
Expansion Valve TXV Liquid Line Gas Line
Heat Pump Kit* Model Used With Connection Connection Shipping
Number AC Units Dia. I.D. (In.) Dia. I.D. (In.) Weight (Ibs.) Refrigerant
21/2 -3 Ton
PHASED OUT
3
TAYTXVH0D3C /8 11/8 2 R-22
3
TAYTXVH0G3C 4 -5 Ton /8 11/8 2 R-22
* Used with TXH coils only where approved for use with 2 compressor systems.

For complete equipment / combination


Effective 1/1/06 AC/IN-10 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Refrigerant Line Sets

Table AC/IN-11-A — Refrigerant Line Sets


Model Gas Line23 Liquid Line Tonnages/W Tonnages/W Shipping
Number Dia. O.D. Dia. O.D. Length R-22 R-410A Weight
5 1
TAYREFLN125 /8 /4 25 1 & 11/2 13
5 1
TAYREFLN130 /8 /4 30 1 & 11/2 15
5 1
TAYREFLN140 /8 /4 40 1 & 11/2 20
5 1
TAYREFLN150 /8 /4 50 1 & 11/2 28
3 5
TAYREFLN225 /4 /16 25 2 & 21/2 21/2 15
3 5
TAYREFLN230 /4 /16 30 2 & 21/2 21/2 18
3 5
TAYREFLN240 /4 /16 40 2 & 21/2 21/2 23
3 5
TAYREFLN250 /4 /16 50 2 & 21/2 21/2 32
7 3
TAYREFLN325 /8 /8 25 3 & 31/2 4&5 20
7 3
TAYREFLN330 /8 /8 30 3 & 31/2 4&5 24
7 3
TAYREFLN340 /8 /8 40 3 & 31/2 4&5 30
7 3
TAYREFLN350 /8 /8 50 3 & 31/2 4&5 39
TAYREFLN425 11/81 3
/8 25 4, 5, & 6 20
TAYREFLN430 11/81 3
/8 30 4, 5, & 6 24
TAYREFLN440 11/81 3
/8 40 4, 5, & 6 30
TAYREFLN450 11/81 3
/8 50 4, 5, & 6 39
1 1
TAYREFLN550 /2 /4 50 1 & 11/ 2 26
5 5
TAYREFLN625 /8 /16 25 2 15
5 5
TAYREFLN630 /8 /16 30 2 17
5 5
TAYREFLN640 /8 /16 40 2 22
5 5
TAYREFLN650 /8 /16 50 2 29
3 3
TAYREFLN725 /4 /8 25 3 & 31/ 2 19
3 3
TAYREFLN730 /4 /8 30 3 & 31/ 2 22
3 3
TAYREFLN740 /4 /8 40 3 & 31/ 2 28
3 3
TAYREFLN750 /4 /8 50 3 & 31/ 2 35
1 Gas line is 7/8 O.D. but expanded out to 1-1/8 on the ends.
2 Gas line 90o bend one end.
3 Gas line insulation 1/2" thickness.
Note: Contains a holding charge of Nitrogen.

For complete equipment / combination


selections and installation instructions, please AC/IN-11 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Base Pan Sizes

Table AC/IN-12-A — Base Pan 4


50 X 37 X 34 46 X 37 X 34 42 X 37 X 34
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
2TTX4048B 2TWX4042B 2TTX4042B 2TWX4036B 4TTX6036B 2TWX4030B
2TTX4060B 2TWX4048B 2TTX5024B 2TWX5030A 2TWX5024A
2TTX5036B 2TWX4060B 2TTX5030B 4TWX4036B
2TTX5042B 2TWX5036A 4TTX4042B 4TWX6036B
2TTX5048B 2TWX5042A
2TTZ9030B 2TWX5048A
2TTZ9036B 2TWZ9030B
2TTZ9048B 2TWZ9036B
2TTZ9060B 2TWZ9048B
4TTX4048B 2TWZ9060B
4TTX4060B 4TWX4042B
4TTX6048B 4TWX4048B
4TTX6060B 4TWX4060B
4TWX6048B
4TWX6060B

Table AC/IN-12-B — Base Pan 3


48 X 33 X 30 44 X 33 X 30 40 X 33 X 30
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
4TWX4024B 4TTX4036B 2TWX4024B 2TTX4018B 2TWX4018B
4TWX4030B 4TTX6024B 4TWX6024B 2TTX4024B 4TWX4018B
2TTX4030B
2TTX4036B
4TTX4018B
4TTX4024B
4TTX4030B

Table AC/IN-12-C — Base Pan 4


41 X 37 X 34 37 x 37 x 34 33 X 37 X 34
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
2TTR2060B 2TWR2060A 2TTR4042A 2TWR3036A 2TTR3042A 2TWR1060A
2TTR3048A 2TWR3042A 4TTR4042A 2TWR4036A 4TTR2060A 2TWR4030A
2TTR3060A 2TWR3048A 4TWR4036A 4TWR2048A
2TTR4048A 2TWR3060A
2TTR4060A 2TWR4042A
4TTR4048A 2TWR4048A
4TTR4060A 2TWR4060A
4TWR2060A
4TWR4042A
4TWR4048A
4TWR4060A

For complete equipment / combination


Effective 1/1/06 AC/IN-12 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Base Pan Sizes

Table AC/IN-13-A — Base Pan 3


41 X 33 X 30 37 X 33 X 30 33 X 33 X 30
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
4TTR2048A 4TWR2042A 2TTR1060A 2TWR2048A 2TTR2042B 2TWR1042A
4TWR4024A 2TTR2048A 2TWR3030A 2TTR3030A 2TWR1048A
4TWR4030A 2TTR4030A 4TWR4024A 2TTR3036A 2TWR2036A
2TTR4036A 4TWR4018A 2TTR4018A 2TWR2042A
4TTR2042A 2TTR4024A 2TWR4018A
4TTR4036A 4TTR2018A 4TWR2018A
4TTR2024A 4TWR2024A
4TTR2030A 4TWR2030A
4TTR2036A 4TWR2036A
4TTR4018A
4TTR4024A
4TTR4030A

Table AC/IN-13-B — Base Pan 2


33 X 29 X 26 29 X 29 X 26 26 X 29 X 26
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
2TTR2036A 2TWR3018A 2TTR1042A 2TWR1030A 2TTR1030A 2TWR1018A
2TTR3024A 2TWR3024A 2TTR1048A 2TWR1036A 2TTR1036A 2TWR1024A
2TTR2024A 2TWR2018A 2TTR2018A
2TTR2030A 2TWR2024A 2TTR3018A
2TWR2030B

Table AC/IN-13-C — Base Pan 1


26 X 20 X 19
Cooling Models Heat Pump Models
2TTR1018A
2TTR1024A

For complete equipment / combination


selections and installation instructions, please AC/IN-13 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Base Pan Sizes

Table AC/IN-14-A — Base Pan 4


41 X 37 X 34 37 X 37 X 34 33 X 37 X 34
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
2TTA0072A 2TWA0072A 2TWA3036A 2TTA3042A 2TWA0060A
2TTA3048A 2TWA2060A 2TWB3036A 2TTB3042A 2TWB0060A
2TTA3060A 2TWA3042A
2TTB3048A 2TWA3048A
2TTB3060A 2TWA3060A
2TWB2060A
2TWB3042A
2TWB3048A
2TWB3060A

Table AC/IN-14-B — Base Pan 3


37 X 33 X 30 33 X 33 X 30
Cooling Models Heat Pump Models Cooling Models Heat Pump Models
2TTA2048A 2TWA2048A 2TTA0060A 2TWA0042A
2TTA2060A 2TWA3030A 2TTA2042A 2TWA0048A
2TTB2048A 2TWB2048A 2TTA3030A 2TWA2036A
2TTB2060A 2TWB3030A 2TTA3036A 2TWA2042A
2TTB0060A 2TWB0042A
2TTB2042A 2TWB0048A
2TTB3030A 2TWB2036A
2TTB3036A 2TWB2042A

Table AC/IN-14-C — Base Pan 2


33 X 29 X 26 29 X 29 X 26 26 X 29 X 26
Cooling Models Heat Pump Models Cooling Models Heat Pump Models Cooling Models Heat Pump Models
2TTA2036A 2TWB3018A 2TTA0042A 2TWA0030A 2TTA0030A 2TWB0012A
2TTB2036A 2TWB3024A 2TTA0048A 2TWA0036A 2TTA0036A 2TWB0018A
2TTB3024A 2TTA2030A 2TWA2030A 2TTB0030A 2TWB0024A
2TTB2024A 2TWB0030A 2TTB0036A 2TWB2018A
2TTB2030A 2TWB0036A 2TTB0042A
2TWB2024A 2TTB0048A
2TWB2030A 2TTB2018A
2TTB3018A

For complete equipment / combination


Effective 1/1/06 AC/IN-14 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Equipment Date
Identification

The nine digit serial numbers on all Trane central air conditioning and heating
products are employed to identify the year and fiscal week of product manufacture.

Year of manufacture .......................... First digit ................................... M124X04CF

Fiscal week of manufacture ............... Second and third digit ............... M124X04CF

Day of week of manufacture .............. Fourth digit ............................... M124X04CF

Consecutive order of production ........ Last Five digits ......................... M124X04CF

Exception – Accessories are an exception to the nine digit serial number


assignment and may have only three digits to indicate date code.
Coils which have only three digits to indicate date code are an exception
to the nine digit serial number assignment.

YEAR DESIGNATIONS FROM 1980


Residential, ID & OD 1 Ducane Oil 1 Residential, ID &OD 1 DucaneOil1
Light Commercial Horizontal Light Commercial Horizontal
Year Products & Compressors Gas Furnaces 2 Year Products & Compressors Gas Furnaces2

1980 O,A L 1995 K 95


1981 T M 1996 L 96
1982 U N 1997 M 97
1983 W P 1998 N 98
1984 X Q 1999 P 99
1985 Y 85 2000 R —
1986 S 86 2001 Z —
1987 B 87 2002 2 —
1988 C 88 2003 3 —
1989 D 89 2004 4 —
1990 E 90 2005 5 —
1991 F 91 2006 6 —
1992 G 92 2007 7 —
1993 H 93 2008 8 —
1994 J 94 2009 9 —

1 Beginning with 1/1/96 (L01) Ducane oil furnace production uses same date
code method as gas furnace. Prior to 1/1/96 Ducane serial number used
last four digits = date code, example HA1234569540 1995, 40th week.

Example: 123456-8 5 4 0

Year of manufacture Fiscal week of manufacture

2 Dedicated horizontal gas furnaces, production ceased after introduction of


convertible furnaces.

For complete equipment / combination


selections and installation instructions, please AC/IN-15 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Refrigerant HCFC 22 (R-22)
Tables contain no allowances for vertical lift!

Table AC/IN-16-A — Allowable Suction Line Diameters and Capacities (R-22)

Note 1: * indicates values more than 10% capacity loss.


Note 2: --- indicates values more than 15% capacity loss.

Table AC/IN-16-B — Liquid Line Selection Table for R-22 Systems

Refrigerant Line Limits


1. Do not use traps.
2. The suction line diameter must be one of the sizes listed.
3. Use the recommended liquid line size unless the total pressure drop (friction loss
plus liquid lift) exceeds: 35 PSI.
4. Refer to 7½ - 20 ton section to determine appropriate refrigerant line size for 7½, 10,
12½, 15 and 20 ton split systems.
5. XL19i - Max length = 80 – of that max length, 25 feet may be vertical.

This page contains limited data for an unskilled user to fully determine if the application will work or to
select required accessories. Please refer to publication #22-3317-01 for complete details and examples.
For complete equipment / combination
Effective 1/1/06 AC/IN-16 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Refrigerant HFC 410A (R-410A)
Tables contain no allowances for vertical lift!
Table AC/IN-17-A

Allowable Liquid Line Diameters and Pressure Drops

Note 1: A blank space indicates a pressure drop of over than 50 PSI.


Note 2: Other existing sources of pressure drop such as (solenoid valves, etc.) must be considered.
Note 3: A vertical run with a heat pump system always results in a liquid lift (heating or cooling).
Note 4: The smallest liquid line diameter that results in a total liquid line pressure drop of 50 PSI or less results in the most reliable system (fewer pounds of R-410A).

Table AC/IN-17-B

Allowable Suction Line Diameters and Capacity Losses

Note * Rated tube size.


Note 1: Shaded value indicates more than 10% capacity loss.
Note 2: Blank space indicates more than 15% capacity loss.
Refrigerant Line Limits
This page contains limited data for an unskilled
1. Do not use traps. user to fully determine if the application will work
2. The suction line diameter must be one of the sizes listed. Use the actual tonnage of or to select required accessories. Please refer to
the system in selecting line sizes. publication #22-3317-01 for complete details and
3. Use the recommended liquid line size unless the total pressure drop (friction loss examples.
plus liquid lift) exceeds: 50 PSI.
4. XL16i - Max length = 80 – of that max length, 25 feet may be vertical.
For complete equipment / combination
selections and installation instructions, please AC/IN-17 Effective 1/1/06
refer to Product Data and/or Installers Guides.
For complete equipment / combination
Effective 1/1/06 AC/IN-18 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
For complete equipment / combination
selections and installation instructions, please AC/IN-19 Effective 1/1/06
refer to Product Data and/or Installers Guides.
7 1/2 - 20 Ton (HCFC-22)
Split System Refrigerant Piping

TTA Liquid Suction Applicable line length and rise:: x=total line length (hor+vert) : y=total line rise
090a 1/2 1- 3/8
120a 1/2 1- 3/8 For 0<=x<=50: x=y
120b 3/8 1- 1/8 For 50<x<=150: y=62.5-.25x
120c 1/2 1- 3/8 50 Call Trane for review
Total
150b 1/2 1- 3/8
Rise
180b 1/2 1- 3/8 25 Acceptable
180c 5/8 1- 5/8
240b 1/2 1- 3/8 50 Total Length 150

TWA Liquid Suction Applicable line length and rise:: x=total line length (hor+vert) : y=total line rise
090a 1/2 1- 3/8
120a 1/2 1- 3/8 for 0<=x<=50: x=y
180b 1/2 1- 3/8 For 50<x<=150: y=62.5-.25x
240b 1/2 1- 3/8 Same as TTA

Explanation:
If the total refrigerant line length is equal to or less than 50 feet, the length of the vertical riser may be = to the total length.
If the total refrigerant line length is greater than 50 feet, then the maximum length of vertical pipe must be figured by using
the second formula.

Example:
Given:
Total refrigerant piping length = 150 feet
Required:
Determine the maximum allowable vertical pipe length.
Solution:
First, determine if the total length is within maximum allowable rules, then determine the maximum vertical length.
The total length exceeds 50 feet and is equal to 150 feet; therefore, the maximum vertical length
= 62.5 ft-(.25 X 150 ft)
= 62.5 ft -37.5 ft
= 25 ft maximum vertical length

For complete equipment / combination


Effective 1/1/06 AC/IN-20 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Branch Circuit Wire Sizing Table/
Heater De-Rating Chart
BRANCH CIRCUIT WIRE SIZING TABLE
(Based on 2% Voltage Drop)
Chart is based on 75˚ C. wire. (Types FEPW, RH, RHW, THHW, THW, THWN, XHHW, USE, AND ZW.)
Use Chart For Wire Sizing Only. Refer To Electrical Code, (Or Product Specs.) For Fuse Sizing
Suitable for 1 Ph. or 3 Ph. Circuits 75˚ C. Insulation; 30˚ C. Ambient Temp. (80˚ F.)
DISTANCE (POWER SUPPLY TO LOAD) IN FEET (208-230V) Not more than three conductors per raceway
10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 145 150 155 160 165 170 175

10 #12 Copper
or
15 #10 Aluminum
20
25
#10 Copper
30
or
35 #8 Aluminum
40 #8 Copper
or
REQUIRED BRANCH CIRCUIT AMPACITY

45
#6 Aluminum
50
55 #6 Copper
60 or
#4 Aluminum
65
70
#4 Copper
75 or
#2 Aluminum
80
85
90
95
#2 Copper
100 or
105
#0 Aluminum

110
115
120
125
130
50 100 150 200 250 300 350
Distance (power supply to load in feet (460V).
See National Electrical Code for Temperature corrections and other variables. All wiring must comply with Local Codes

Heater De-Rating Chart


The output of electric heaters, applied at voltages other than the rated 240 or 480 volts, can be
easily determined with the use of this chart.

For complete equipment / combination


selections and installation instructions, please AC/IN-21 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Basic Air Conditioning Formulas

Basic Air Conditioning Formulas


EXPRESSED
TO DETERMINE AS
Application NT V
COOLING HEATING and/or HUMIDIFYING
NT V
Total Airflow CFMT 1. CFMT = 1. CFMT =
Guide 60 min./hr. 60 min./hr.

NO V No V
Infiltration or Ventilation CFMo 2. CFMo = 2. CFMo =
60 min./hr. 60 min./hr.

Number of Air Changes CFMT (60 min./hr.) CFMT (60 min./hr.)


NT 3. NT = 3. NT =
Per Hour – Total V V

Number of Air Changes CFMo (60 min./hr.) CFMo (60 min./hr.)


Per Hour – Outdoor Air No 4. No = 4. No =
V V

Total Heat (HT) Btuh 5. HT = CFMT x 4.5 x (h1 – h2) = Btuh 6. HT = CFMT x 4.5 x (h2 – h1) = Btuh

Sensible Heat (HS) Btuh 7. HS = CFMT x 1.08 x (T1 – T2) = Btuh 8. HS = CFMT x 1.08 x (T2 – T1) = Btuh

Latent Heat (HL) Btuh 9. HL = CFMT x .68 x (W1 – W2) = Btuh 10. HL = CFMT x .68 x (W2 – W1) = Btuh

CFMo CFMo
Entering Air Temperature (T1) °F. D.B. 11. T1 = t1 + x (t2 – t1) = °F.D.B. 1 12. T1 = t1 – x (t1 – t2) = °F.D.B. 2
CFMT CFMT
(Mixed Air)
1 If duct heat gain is a factor, add to T1: 2 If duct heat loss is a factor, subtract from T1:
Duct Heat Gain (Btuh) Duct Heat Loss (Btuh)
CFMT x 1.08 CFMT x 1.08

Leaving Air D.B. HS HS


°F. D.B. 13. T2 = T1 – = °F.D.B. 14. T2 = T1 + = °F.D.B.
Temperature (T2) CFMT x 1.08 CFMT x 1.08
HS (total) HS
Required Airflow CFMT 15. CFMT = = CFM 16. CFMT = = CFM
1.08 x (T1 – T2) 1.08 x (T2 – T1)
OR
HS (internal)3
CFMT = = CFM
1.08 x (t1 – T2)
3 Sensible load of outside air not included

Btu/lb. HT HT
Enthalpy – Leaving Air (h2) 17. h2 = h1 – = Btu/lb. dry air 18. h2 = h1 + = Btu/lb. dry air
dry air CFMT x 4.5 CFMT x 4.5

19. Refer to Enthalpy Table and read W.B. temperature 20. Refer to Enthalpy Table and read W.B. temperature
Leaving Air W.B. Temperature °F.W.B.
corresponding to enthalpy of leaving air (h2) (see #17). corresponding to enthalpy of leaving air (h2) (see #18).
Heat Required to Evaporate
Water Vapor Added to Btuh 21. HL = CFMo x .68 (W3 – Wo) = Btuh 22. HL = CFMo x .68 (W3 – Wo) = Btuh
Ventilation Air
Excess Latent Capacity
HL loss Btuh (see #22)
Humidification Requirements
Lbs.
water/hr.
23.
( Moisture )
Make up = of System x % Run Time
1060 Btu/lb.
= lbs./hr.
(
24. Make up =
Moisture ) 1060 Btu/lb.
= lbs./hr.

(Industrial Process Work)

LEGEND DERIVATION OF AIR CONSTANTS


CFMT = Total airflow cubic feet/min. The air constants below apply specifically to standard air which is
CFMo = Outdoor air cubic feet/min. defined as dry air at 70°F and 14.7 P.S.I.A. (29.92 in. mercury column).
NT = Total air changes per hour They can, however, be used in most cooling calculations unless extremely
No = Outdoor air, air changes per hour precise results are desired.
V = Volume of space cubic feet 4.5 (To convert CFM to lbs./hr.)
HT = Total heat Btuh
HS = Sensible heat Btuh 60 min./hr.
4.5 = or 60 X .075
HL = Latent heat Btuh 13.33
* h1 = Enthalpy or total heat of entering air Btu/lb. Where 13.33 is the specific volume of standard air (cu.ft./lb.) and
* h2 = Enthalpy or total heat of leaving air Btu/lb. .075 is the density (lbs./cu.ft.)
T1 = Temperature of entering air .24 X 60
T2 = Temperature of leaving air 1.08 = or .24 X 4.5
13.33
Tadp = Apparatus dewpoint °F.D.B.
.24 BTU = specific heat of standard air (BTU/LB/°F)
t1 = Indoor design temperature °F.D.B.
t2 = Outdoor design temperature °F.D.B. .68 =
60
X
1060
or 4.5 X
1060
W1 = Grains of water/lb. of dry air at entering condition Grains/lb. 13.33 7000 7000
W2 = Grains of water/lb. of dry air at leaving condition Grains/lb.
Where: 1060 = Average Latent Heat of water vapor (BTU/LB.).
W3 = Grains of water/lb. of dry air at indoor design conditions Grains/lb.
Wo = Grains of water/lb. of dry air at outdoor design conditions Grains/lb. 7000 = Grains per lb.

* See Enthalpy of air (Total Heat Content of Air) Table for exact values.

For complete equipment / combination


Effective 1/1/06 AC/IN-22 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Low Ambient Accessories
Cooling Models

Model
Family 55oF 45oF 30oF OoF

As As
XL19i AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped Shipped
As As
XL16i AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped Shipped
As As
XL15i AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped Shipped
XL14i As
TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
XR14 As
TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
As Quick Start Solenoid
XR13 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
Shipped Kit Valve 3
As
XR12 - R-410A TXV7 AY28X079 TXV-NB7 BAYCCHT* Not Approved
Shipped
As Quick Start Solenoid
XR12 - R-22 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
Shipped Kit Valve 3
2TTA3 / As 3 phase Solenoid
2TTA2 / 2TTA0 shipped
TXV7 AY28X079 TXV-NB7 ** BAYLOAM103 TXV-NB 7 ** not needed Valve 3
2.5 to 5 Ton As Quick Start Solenoid
TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
XR11 Shipped Kit Valve 3
1.5 to 2 Ton As Quick Start Solenoid
TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB 7 BAYCCHT*
XR11 Shipped Kit8 Valve 3
As Quick Start Solenoid
XB13 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
Shipped Kit Valve 3
As Quick Start Solenoid
XB12 TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
shipped Kit Valve 3
2.5 to 5 Ton As Quick Start Solenoid
TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB 7 BAYCCHT*
XB10 Shipped Kit Valve 3

TTB012 thru 024 As Quick Start Solenoid


TXV7 AY28X079 TXV-NB7 BAYCCHT* BAYLOAM104 TXV-NB 7 BAYCCHT*
Shipped Kit8 Valve 3
Notes:
1 Scroll compressors unload during the off cycle and do not require hard start components due to refrigerant pressure differential. However, it is
recommended to install start kit when operating below 30°F.
2 For all systems employing head pressure control, a non-bleed thermal expansion valve (NB-TXV) is required. TWE060A has a factory installed bleed
port TXV. If belt drive is preferred (TWE060A), it is recommended to change the TXV to a non-bleed type.
3 If off cycle time exceeds 30 minutes at low outdoor ambient conditions, it is recommended to install a liquid line solenoid valve.
a) If solenoid valve is required, pressure drop across the solenoid valve plus liquid line pressure drop shall be no greater than 35 PSI for R-22 systems
and 50 PSI for R410A systems.
4 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.
5 System indoor airflow shall be no less than 370 CFM / Ton when applying head pressure control.
6 Check Product Data General Specification page in order to determine if the condensing unit ships with required components such as crankcase heat or
start components.
7 If non bleed thermal expansion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start compo-
nents. Check Product Data for factory-installed components in order to determine if a quick start accessory is required.
8 BAYLOAM104 includes integrated quick start kit.
* Please refer to Product Data.
** BAYCCHT (Crankcase Heater) is factory installed.

For a detailed Application Bulletin on required accessories and wind shields for low
outdoor ambient operation, please contact your Territory Manager or Local FSR.
For complete equipment / combination
selections and installation instructions, please AC/IN-23 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Low Ambient Accessories
Heat Pump Models

Model
Family 55oF 45oF 30oF34 OoF34

As
XL19i As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
As
XL16i As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
As
XL15i As Shipped AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
XL14i As
TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
XR14 As
TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved
R-22 / R-410A Shipped
As Quick Start
XR13 TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
As
XR12 - R410A TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* Not Approved
Shipped
As Quick Start
XR12 - R-22 TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Quick Quick
As Quick Start
XR11 TXV-NB7 Start AY28X084 TXV-NB7 Start BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Kit Kit
As Quick Start
XB13 TXV-NB7 AY28X084 TXV-NB7 BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Quick Quick
As Quick Start
XB12 TXV-NB7 Start AY28X084 TXV-NB7 Start BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Kit Kit
Quick Quick
As Quick Start
XB10 TXV-NB7 Start AY28X084 TXV-NB7 Start BAYCCHT* BAYLOAM103 TXV-NB7 BAYCCHT6
Shipped Kit6
Kit Kit
2TWA3 / As 3 3
2TWA2 / 2TWA0 Shipped
TXV-NB7
phase
AY28X084 TXV-NB7
phase ** BAYLOAM103 TXV-NB7 ** 3 phase

Notes:
1 Scroll compressors unload during the off cycle and do not require hard start components due to refrigerant pressure differential. However, it is
recommended to install a start kit when operating below 30°F.
2 For all systems employing head pressure control, a non-bleed thermal expansion valve (NB-TXV) is required. All heat pump expansion valve accesso-
ries are non-bleed type. TWE060A has a factory installed bleed port TXV. If belt drive is preferred (TWE060A), it is recommended to change the TXV to
a non-bleed type.
3 Wind shields may be required, please refer to the following pages to locate documentation regarding windshields.
4 System indoor airflow shall be no less than 370 CFM / Ton.
5 Do not use solenoid valves with heat pump systems.
6 Check Product Data General Specification page in order to determine if the heat pump unit ships with required components such as crankcase heat or
start components.
7 If non bleed thermal expansion valve is used in a system bearing a reciprocating style compressor, the condensing unit must have quick start compo-
nents. Check Product Data for factory-installed components in order to determine if a quick start accessory is required.
* Please refer to Product Data.
** BAYCCHT (Crankcase Heater) is factory installed.

For a detailed Application Bulletin on required accessories and wind shields for low
outdoor ambient operation, please contact your Territory Manager or Local FSR.
For complete equipment / combination
Effective 1/1/06 AC/IN-24 selections and installation instructions, please
refer to Product Data and/or Installers Guides.
Wind Shields

Wind Shields are required to block operation is required to 0°F, wind


prevailing winds across condenser shields are a Must. Use the following
coil. In applications where cooling guidelines for your application.

Notes:
Minimum working clearance must be in compliance with the National Electric Code. Currently,
the minimum clearance between a wood or suitable grounding material type fence requires
minimum 3 feet. If other material is used to form the windshield, the minimum space may be
increased to 3.5 feet. Please consult the 2002 Edition of the National Electric Code, Article 110
for the most up to date information, please refer to the most current National Electric Code.

For a detailed Application Bulletin on required accessories and wind shields


for low ambient operation, please contact your Territory Manager or Local FSR.

For complete equipment / combination


selections and installation instructions, please AC/IN-25 Effective 1/1/06
refer to Product Data and/or Installers Guides.
Literature Order Number
P.O. Box 9010 File No. Pub. No. 22-8301-15 1/06
TylerTX 75711-9010
http://www.trane.com Supersedes Pub. No. 22-8301-14 10/05
(Electronic Only)
Stocking location PI (L)
A Business of American Standard
Companies. Since Trane has a policy of continuous product improvement, it reserves the right to change design and
specifications without notice.
© 2006 American Standard All rights reserved