Ke - FRXX: Multi Range, Time Adjusted Flasher Relay

This document provides information about a microprocessor-controlled multi-range time adjustment flasher relay. It can be used to select from 16 different time intervals using dip switches, and the interval can be finely adjusted using a potentiometer. Connections are made via terminals to a connection rail in an electrical panel.

Uploaded by

dhafer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
30 views

Ke - FRXX: Multi Range, Time Adjusted Flasher Relay

This document provides information about a microprocessor-controlled multi-range time adjustment flasher relay. It can be used to select from 16 different time intervals using dip switches, and the interval can be finely adjusted using a potentiometer. Connections are made via terminals to a connection rail in an electrical panel.

Uploaded by

dhafer
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ke – FRXX

MULTI RANGE, TIME


ADJUSTED FLASHER RELAY General:
► 16 Time interval selection It is microprocessor controlled. It is possible to make 16 different time interval selections by using the dip-switch that is
located near the equipment.
► 230 Vac or 24 V ac/dc

T T T T T T T

► TIME INTERVAL SELECTION:


You may select the desired time interval
by using the 1,2,3,4 numbered switches
off of the dip-switch that are at the side of
(t) the equipment. The time selection table is
Time given below.
Adj.

on

Min - Max Min - Max


0,1 – 1sec 9 sec - 15 min
1 2 3 4 1 2 3 4

0,1 – 5sec 18 sec – 30 min


1 2 3 4 1 2 3 4

0,1 – 10sec 36 sec – 60 min


1 2 3 4 1 2 3 4

0,3 – 30sec 3 min – 5 hrs


1 2 3 4 1 2 3 4

0,6 – 60sec 6 min – 10 hrs


1 2 3 4 1 2 3 4

1 – 100sec 9 min – 15 hrs


1 2 3 4 1 2 3 4
A1 15
3 sec - 5 min 15 min – 25 hrs
230 Vac 1 2 3 4 1 2 3 4

A2 6 sec – 10 min 18 min – 30 hrs


16 18 1 2 3 4 1 2 3 4

A3 15

24 Vac/dc

A2 16 18
Simple Connection :
► THE TIME ADJUSTMENT SCALER:
TECHNICAL DATA: The scaler of the adjustment potentiometer located on
the equipment, can be set between 0,1 to 1.
Operational Voltage (Un) When you select your adjustment with the dip-switch, L1
A1 – A2 terminals : 230 Vac it can be adjusted at the range specified by the L2
A3 – A2 terminals : 24 Vac or 24 Vdc interval mode, by the steps of 1%. L3
Operating Range : (0.8 – 1.1)xUn 24 Vac
(Un nominal voltage) 24 Vdc
Frequency : 50/60 Hz Example :
Contact Current : Max. 5 A / 240 VAC
Power Consumption : < 8 VA
Device Protection 1sec–100sec
Class : IP20 1 2 3 4
Connector Protection N
Class : IP00 If you had already selected the time interval mode
Ambient Temperature : -5°C....+50°C above, in the situation of the potentiometer becoming
Connection Type : To connection rail maximum, the relay would have counted 100 sec; K1
in electrical panel while in minimum, it would have counted 1 sec. You
Dimensions : 23x82x80 mm can do your adjustment at steps of 1 sec. (The min. T1
value in the table is the adjustment step period)

Load
16 mm
mm
80

N
23 mm 35 mm
82 mm