0% found this document useful (0 votes)
459 views7 pages

KL-730 - Biomedical Measurement Training System

The document describes the KL-730 Biomedical Measurement Training System. It consists of 12 modules covering topics like ECG, EMG, EEG, blood pressure measurement, and respiration monitoring. The system allows students to learn how to extract body signals using sensors, process the signals, and observe and analyze the outputs. It has test points, sensors, data display and storage capabilities, and software for signal analysis.

Uploaded by

KJ Ikhwan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
459 views7 pages

KL-730 - Biomedical Measurement Training System

The document describes the KL-730 Biomedical Measurement Training System. It consists of 12 modules covering topics like ECG, EMG, EEG, blood pressure measurement, and respiration monitoring. The system allows students to learn how to extract body signals using sensors, process the signals, and observe and analyze the outputs. It has test points, sensors, data display and storage capabilities, and software for signal analysis.

Uploaded by

KJ Ikhwan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Biomedical Measurement Equipment

KL-730
Biomedical Measurement Training System
The Biomedical Measurement Training System
(KL-730) provides a platform for students to learn how
to extract various body signals using bio-electronics
sensors. There are a total of 12 modules covering a
variety of topics, including: Electrocardiogram (ECG),
Electromyogram (EMG), Electrooculogram (EOG),
Electroencephalogram (EEG), Blood pressure (BP),
Photoplethysmogram (PPG), Respiratory ventilation
detection, Pulse meter measurement, Body impedance
detection, Doppler ultrasound blood velocity measurement,
and Respiration flow/vital capacity meter measurement.
Through the system, students can construct a
circuit to process and convert signals into readable
forms for further observation and analysis. Also,
hands-on practices and experiments allow students to
understand the characteristics of various bio-electronics
sensors and transducers.
* Notebook is excluded

Features
1. There are test points for adjustment of frequency bandwidth and amplifier gain, allowing students to learn the relationship
between a circuit and a corresponding signal on each processing stage.
2. The system consists of several bio-electronics sensors and transducers, including pressure transducers, infrared photocouplers,
strain gauges, temperature sensors, surface electrodes, dual element transducers, and pneumotach transducers.
3. Display and storage of signals
The main unit of the system (KL-76001) has a 128 x 64 LCD graphic display to show the real-time physiological parameters.
Physiological signals can be displayed on a digital storage oscilloscope (DSO).
4. With embedded 10-bit A/D converters (2.4 Kbits/s), physiological signals can be converted to digital forms and transmitted to
computers in real-time via a USB port.
5. Graphic user interface software
(1) Communication port : USB
(2) Physiological signal can be analyzed after connection
(3) Easy operation
(4) X-axis : TIME/DIV ; Y-axis : VOLT/DIV
(5) Data can be stored, replayed, or printed
(6) Storage formats : *.BMP, *.JPEG,*.XLS
(7) Measurements of ECG, EMG, EOG, EEG, blood pressure, respiration flow/vital capacities are available for analysis.

Biomedical Measurement System 7


KL-730

Specifications 4. Reset Switch


} Main Unit (KL-76001) for MCU reset
1 6 7 8 5. Select Switch
for selection of the modules
9 6. LCD Status Display
(1) Display the output frequency of the function generator
(2) Display the module selected
(3) Display Heart Rates (KL-75006), Respiration (KL-75007),
2 Pulse Rates (KL-75008) and Doppler Ultrasound
3
Blood(KL-75010).
4 7. BNC Adaptor Connector
5 for 2mm sockets / BNC sockets
KL-76001 8. Module Output
DB9 connector
1. Function Generator
9. Output
(1) Output Waveform : Sine, Square, and Triangle.
(1) Electrocardiogram (ECG) : 1 output
(2) Frequency Range : 0.01Hz ~ 1MHz,
(2) Electromyogram (EMG) : 2 outputs
continuously adjustable
(3) Electrooculogram (EOG) : 2 outputs
(3) Amplitude Range : 50mVpp ~ 18Vpp (open circuit)
(4) Electroencephalogram (EEG) : 1 output
(4) DC Offset : - 10V to +10V
(5) Blood pressure measurement : 2 outputs
(5) Display : 4-digit,7-segment display
(6) Photoplethysmogram : 2 outputs
2. Interface Port
(7) Respiratory ventilation : 2 outputs
USB Interface : Type B
(8) Pulse meter : 2 outputs
3. Input Indicators (9) Impedance : 1 output
IN1、IN2、IN3、IN4、IN5 LEDs, indicating the corresponding (10) Doppler Ultrasound Blood Velocity : 2 outputs
connection for students when conducting experiments of ECG, (11) TENS : 1 output
EMG, EOG, EEG and body impedance. (12) Respiration Flow / Vital Capacity Meter : 2 outputs

} Module Units (KL-75001~75012)


KL-75001 Electrocardiogram ECG Module
Feature:
Understand the potential phenomenon when the heart beats. This
measurement module uses 6 limb leads to detect the electrocardiogram.
With the explicit experimental procedure, students can easily learn how
to design the Wilson network and the isolated circuits.

Specifications List of Experiments Equipment Required

1. Limb lead inputs 1. HPF Characteristic Experiment 1. KL-76001 Main Unit


2. Limb electrode 2. Amplifier Experiment 2. KL-75001 Electrocardiogram Module
3. 6 limb leads : Lead I, Lead II, Lead III, 3. LPF Characteristic Experiment 3. Digital Storage Oscilloscope (Option)
aV R , aV L, aV F 4. BRF Characteristic Experiment 4. Lead Clamp - ⑥
4. Isolation circuit 5. ECG Simulator Experiment (Option) 5. Electrode Lead - 17
5. Gain : 100~5000 6. ECG Experiment 6. 5-Conductor Electrode Cable - 18
6. Band-pass filter : 0.1~100Hz 7. Alcohol Prep. Pad - ⑪
7. 1 output 8. Trimmer
ECG signal 9. Connection Leads - 20
10. 2mm Bridging Plug - 21
11. 2mm Terminal - 22
12. KL-79106 ECG Simulator (Option)

8 Biomedical Measurement System


KL-730

KL-75002 Electromyogram EMG Module


Feature:
Understand the electrical activity of muscle under the isotonic and isometric conditions
and simultaneously detect the amount of muscle force. From the measured waveform,
students can realize the motion function made by the specific skeletal muscle.

Specifications List of Experiments Equipment Required

1. Surface electrode 1. BRF Characteristic Experiment 1. KL-76001 Main Unit


2. Gain : x 1000, x 2000 2. LPF Characteristic Experiment 2. KL-75002 Electromyogram Module
3. Isolation circuit 3. Gain Amplifier Experiment 3. Digital Stora ge Oscilloscope (Option)
4. Band-pass filter : 100 ~1000Hz 4. HPF Characteristic Experiment 4. Body Surface Electrodes - ⑧
5. 2 outputs 5. Half-Wave Rectifier Characteristic 5. Electrode Lead - 17
6. 5-Conductor Electrode Cable - 18
(1) Electromyogram signal Experiment
7. Alcohol Prep. Pad - ⑪
(2) Muscle force signal 6. Integrator Characteristic Experiment
8. Dumbbell - ①
7. EMG Experiment 9. Trimmer
10. Connection Leads - 20
11. 2mm Bridging Plug - 21
12. 2mm Terminal - 22

KL-75003 Electrooculogram EOG Module


Feature:
Have a thorough grasp of the electrical activity of the eye muscle under eye movements.
Two kinds of electrical signals from horizontal and vertical movements of the eyeball are
detected and processed in the module.

Specifications List of Experiments Equipment Required

1. Surface electrode 1. Horizontal & Vertical Electro Circuit 1. KL-76001 Main Unit
2. Gain : 5~3000 Calibration Experiment 2. KL-75003 Electrooculogram Module
3. Isolation circuit 2. BRF Characteristic Experiment 3. Digital Storage Oscilloscope (Option)
4. Band-pass filter : 0.05~30Hz 3. HPF Characteristic Experiment 4. Body Surface Electrodes - ⑧
5. 2 outputs 4. Amplifier Experiment 5. Electrode Lead - 17
(1) Horizontal signal 5. LPF Characteristic Experiment 6. 5-Conductor Electrode Cable - 18
(2) Vertical signal 6. EOG Experiment 7. Alcohol Prep. Pad - ⑪
8. Trimmer
9. Connection Leads - 20
10. 2mm Bridging Plug - 21
11. 2mm Terminal - 22

KL-75004 Electroencephalogram EEG Module


Feature:
Understand the electrical activity of the brain. In the experimental procedure,
theα-wave will be evoked when the eyes open and close. Because the EEG signal
is very weak, this module implements a high gain amplifier and filters to reduce noise.

Specifications List of Experiments Equipment Required

1. EEG electrode 1. Pre-Amplifier Calibration Experiment 1. KL-76001 Main Unit


2. Gain : 50~5000 2. BRF Characteristic Experiment 2. KL-75004 Electroencephalogram Module
3. Digital Storage Oscilloscope (Option)
3. Isolation circuit 3. HPF Characteristic Experiment
4. EEG Electrode - 16
4. Band-pass filter : 1~20Hz 4. Amplifier Experiment 5. 5-Conductor Electrode Cable - 18
5. 1 output 5. LPF Characteristic Experiment 6. Alcohol Prep. Pad -⑪
EEG signal 6. EEG Experiment 7. Electrical Conductivity Jelly - ②
8. Medical Tape - ⑩
9. Elastic Head Bandage - ⑨
10. Trimmer
11. Connection Leads - 20
12. 2mm Bridging Plug - 21
13. 2mm Terminal - 22
14. EEG Simulator (Option)

Biomedical Measurement System 9


KL-730

KL-75005 Blood Pressure Measurement Module


Feature:
Realize how to measure the blood pressure noninvasively and compare the accuracy
between the measurement from the auscultator and from the oscilloscope. In this experiment,
students know the way to calibrate the pressure transducer directly and indirectly.

Specifications List of Experiments Equipment Required

1. Pressure transducer: 1. Pressure Sensor Calibration Experiment 1. KL-76001 Main Unit


(1) Differential pressure model 2. HPF1 Characteristic Experiment 2. KL-75005 Blood Pressure
(2) Pressure range : 0~5 psid 3. LPF Characteristic Experiment Measurement Module
(3) Accuracy : 0.5% 4. HPF2 & Amplifier Characteristic 3. Digital Storage Oscilloscope (Option)
(4) Input impedance : 5K Ω Experiment 4. Mechanical Sphygmomanometer - ④
2. Pressure calibration circuit 5. Rectifier Characteristic Experiment 5. Trimmer
3. Gain amplifier : 20~800 6. Auscultatory Blood Pressure 6. Connection Leads - 20
4. Band-pass filter : 0.3~3Hz measurement Experiment 7. 2mm Bridging Plug - 21
5. 2 outputs 7. Oscillometric Blood Pressure 8. 2mm Terminal - 22
(1) Cuff pressure signal Measurement Experiment
(2) Oscillometric pulse signal

KL-75006 Photoplethysmogram Module


Feature:
Understand how to use the noninvasive method and configure the circuit to detect and
process the Plethysmogram. The volume change in blood capillary is detectable by an
infrared photocoupler.

Specifications List of Experiments Equipment Required

1. Infrared light-emitting diode 1. Infrared Photocoupler Calibration 1. KL-76001 Main Unit


(1) Rated forward current Experiment 2. KL-75006 Photoplethysmogram Module
IF = 60mA 2. HPF Characteristic Experiment 3. Digital Storage Oscilloscope (Option)
(2) Rated reverse voltage 3. Gain Amplifier Experiment 4. Infrared Photocoupler Sensor - 13

VR = 4V 4. 4th-order LPF Characteristic 5. Trimmer


(3) Peak wavelength Experiment 6. Connection Leads - 20
λp = 880nm 5. Differentiator Experiment 7. 2mm Bridging Plug - 21
8. 2mm Terminal - 22
(4) Δθ = ± 53deg. 6. Amplifier Experiment
2. Phototransistor 7. Comparator Experiment
(1) Rated C-E voltage 8. Monostable Multivibrator Experiment
VCEO = 20V 9. Photoplethysmogram
(2) Rated collector power Measurement Experiment
Pc = 75mW
(3) Peak wavelength
λp = 800nm
d. Δθ = ± 50deg.
3. Gain : x 50~500, x 100~1000
4. Band-pass filter : 0.3~40Hz
5. 2 outputs
(1) Plethysmogram signal
(2) Heart rate pulse

10 Biomedical Measurement System


KL-730

KL-75007 Respiratory Ventilation Module


Feature:
After practicing using temperature sensors and configuring circuits, users can understand
how to detect and process respiratory signals including stop breathing capacity, over-respiration,
and respiratory rate.

Specifications List of Experiments Equipment Required

1. Temperature sensor 1. Differential Amplifier Calibration 1. KL-76001 Mai n Unit


(1) Thermistor : 5KΩ (at 25°C) Experiment 2. KL-75007 Respiratory Ventilation Module
(2) Tolerance : ±5% 2. BRF Characteristic Experiment 3. Digital Storage Oscilloscope (Option)
2. With temperature compensation circuit 3. Amplifier Experiment 4. Temperature Sensor Mask - ⑦
3. Gain : 20 4. Differentiator Experiment 5. Trimmer
4. 2 outputs 5. Hysteresis Comparator Experiment 6. Alcohol Prep. Pad - ⑪
(1) Pneumograph signal 6. Monostable Multivibrator Experiment 7. Connection Leads - 20
(2) Respiratory rate pulse 7. Respiratory Ventilation Detection 8. 2mm Bridging Plug - 21
Experiment 9. 2mm Terminal - 22

KL-75008 Pulse Meter Module


Feature:
Understand how to use the strain gauge and configure the circuit to detect and process
the waveforms of the radial pulse and learn the characteristics the vascular under various
transmural pressure conditions.

Specifications List of Experiments Equipment Required

1. Strain gauge 1. Strain Gauge Amplifier Calibration 1. KL-76001 Main Unit


5 mm grid, 120Ω Experiment 2. KL-75008 Puls e Meter Module
2. Gain : x 2500, x 5000 2. HPF Characteristic Experiment 3. Digital Storage Oscilloscope (Option)
3. Band-pass filter : 0.05 ~ 40Hz 3. BRF Characteristic Experiment 4. Strain Gauge Tie - 12
4. 2 outputs 4. Gain Amplifier Experiment 5. Wrist-type Cuff - ⑤
(1) Pulse wave 5. LPF Characteristic Experiment 6. Mechanical Sphygmomanometer - ④
(2) Heart rate pulse 6. Hysteresis Comparator Experiment 7. Trimmer
7. Monostable Multivibrator Experiment 8. Connection Leads - 20
8. Pulse Meter Experiment 9. 2mm Bridging Plug - 21
9. Arterial Vessel Experiment 10. 2mm Terminal - 22

KL-75009 Impedance Module (People with cardiac pacemaker must avoid using this module)

Feature:
Realize how to detect the body impedance. When students Inject a constant alternating
current to the body and the alternating current passes through the chest, a change of body
impedance will be detected when the chamber volume of both the ventricle and atrium is
changed.

Specifications List of Experiments Equipment Required

1. Band-pass filter : 0.1~10Hz 1. Pre-Amplifier Calibration Experiment 1. KL-76001 Main Unit


2. Sine wave generator circuit : 50KHz 2. BRF Characteristic Experiment 2. KL-75009 Impedance Module
3. Surface electrode 3. Wien-Bridge Oscillator Experiment 3. Digital Storage Oscilloscope (Option)
4. Isolation circuit 4. HPF Characteristic Experiment 4. Body Surface Electrodes - ⑧
5. Gain : x 1250, x 2500 5. Demodulator Experiment 5. Electrode Lead - 17
6. With overcurrent protection and reset 6. Gain Amplifier Experiment 6. 5-Conductor Electrode Cable - 18
circuits 7. LPF Characteristic Experiment 7. Alcohol Prep. Pad - ⑪
7. 1 output 8. Impedance Dete ction Experiment 8. Trimmer
Body impedance signal 9. Connection Leads - 20
10. 2mm Bridging Plug - 21
11. 2mm Terminal - 22

Biomedical Measurement System 11


KL-730

KL-75010 Doppler Ultrasound Blood Velocity Module


Feature:
Understand the operating principles of ultrasonic sensors, how the ultrasound probe
measures the velocity of blood flow, and the fundamental circuit theory of the ultrasound probe.

Specifications List of Experiments Equipment Required

1. Dual Element Transducer 1. OSC Experiment 1. KL-76001 Main Unit


Frequency : 5MHz 2. Pre-Amplifier Experiment 2. KL-75010 Doppler ultrasound blood
2. Gain : 16~100 3. Demodulation Experiment velocity module
3. Digital Storage Oscilloscope (Option)
3. Band-pass filter : 1~40Hz 4. HPF Characteristic Experiment 4. Dual Element Transducers Sensor - 23
4. 2 Outputs 5. Amplifier Experiment 5. Trimmer
(1) Plethysmogram signal 6. LPF Characteristic Experiment 6. Alcohol Prep. Pad - ⑪
(2) Heart rate pulse 7. Comparator Experiment 7. Connection Leads - 20
8. Monostable Multivibrator Experiment 8. 2mm Bridging Plug - 21
9. 2mm Terminal - 22
10. Electrical conductivity jelly - ②

KL-75011 TENS Module (People with cardiac pacemaker must avoid using this module)
Feature:
Understand the fundamental circuit theory of the transcutaneous electrical nerve
stimulation (TENS) and the physiological responses of muscles which are stimulated
by different frequencies and amplitudes.

Specifications List of Experiments Equipment Required

1. Electrode lead 1. 555 Timer-Astable Experiment 1. KL-76001 Main Unit


2. 1 Output 2. Transistor Switch Circuit Experiment 2. KL-75011 TENS module
555 Timer-Astable signal 3. Transistor Bias Circuit Experiment 3. Digital Storage Oscilloscope (Option)
(1) Frequency Adjust : 25~115Hz 4. Body surface electrodes (for KL-75011) - 14
(2) Duty Cycle : 91~98% 5. Electrode lead (for KL-75011) - 15
6. Connection Leads - 20
7. 2mm Bridging Plug - 21
8. 2mm Terminal - 22

KL-75012 Respiration Flow / Vital Capacity Meter Module


Feature:
Understand the respiratory parameters (including the respiratory volume and respiratory
flow) and the measurement of the basic circuit.

Specifications List of Experiments Equipment Required

1. Pneumotach transducer 1. Hall & Differential Experiment 1. KL-76001 Main Unit


(1) Excitation voltage : 6V 2. Frequency to Voltage Experiment 2. KL-75012 Respiration flow / Vital capacity
(2) Flow range : 2-35L/min 3. Comparator Experiment meter module
(3) Resolution : 700P/L 4. AND Gate Experiment 3. Digital Storage Oscilloscope (Option)
(4) Maximum operation pressure : 25 Bar 5. Decade Counter Experiment 4. Respiration transducer - 19
2. 2 Outputs 6. Decoder Experiment 5. Trimmer
(1) Respiration flow signal 7. 7-Segment Experiment 6. Connection Leads - 20
(2) Counting pulse 7. 2mm Bridging Plug - 21
8. 2mm Terminal - 22

12 Biomedical Measurement System


KL-730

The Features of the Experiment Modules


1. All terminals on the module are connectable with 2mm plugs.
2. Circuit symbols, blocks, and components are printed on the surface of each module.
3. Modules are secured in plastic housings.
4. Dimension : 255 x 165 x 30mm ± 10%
5. Comprehensive experiment and instructor's manuals are provided.

System Requirement
1. Above INTEL P4 compatible PC 4 . Disk space more than 2G bytes
2. USB port 5. DVD-ROM driver for installing PC
3. Above 1G bytes memory 6. OS : Windows 7 / 8 / 10

Accessories
} Optional Accessories Consumables
1. Digital Storage Oscilloscope (DSO) 1. Electrical conductivity jelly Digital Storage Oscilloscope
2. KL-79106 ECG simulator 2. Body surface electrode
3. Alcohol prep pad
3. EEG simulator
4. Elastic head bandage
5. Temperature sensor mask
6. Medical tape
7. Body surface electrode (for KL-75011)
KL-79106 ECG simulator EEG simulator
(Pathological Signals)

} Standard Accessories (KL-79003)


① Dumbbell

① ③ ② Electrical conductivity jelly
③ Accessory box
⑤ ④ Mechanical sphygmomanometer

⑤ Wrist-type cuff
⑥ Lead clamp
⑥ ⑦ Temperature sensor mask
⑧ Body surface electrodes
⑦ ⑪
⑧ ⑨ Elastic head bandage

⑩ ⑩ Medical tape
⑪ Alcohol prep pad

⑫ Strain gauge tie


⑬ Infrared photocoupler sensor ⑫ ⑬ ⑭ ⑮
⑭ Body surface electrode for KL-75011
⑮ Electrode lead for KL-75011
⑯ EEG electrode ⑯ ⑰ ⑱
⑰ Electrode lead
⑱ 5-conductor electrode cable ⑲

⑲ Respiration transducer
21
⑳ Connection leads
21 2mm bridging plug 23
22
22 2mm terminal
23 Dual Element transducer

10901 Biomedical Measurement System 13