0% found this document useful (0 votes)
445 views

Pile Cap Design Calculations With CSI SAFE

This document provides details for designing a pile cap footing, including input data on column dimensions, material properties, pile properties from a geotechnical report, loading data, and calculations for pile spring stiffness. It specifies an 11x4 pile arrangement to support the given axial and moment loads. Diagrams illustrate the pile labeling convention and critical sections for checking shear capacity.

Uploaded by

Ehsan Sh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
445 views

Pile Cap Design Calculations With CSI SAFE

This document provides details for designing a pile cap footing, including input data on column dimensions, material properties, pile properties from a geotechnical report, loading data, and calculations for pile spring stiffness. It specifies an 11x4 pile arrangement to support the given axial and moment loads. Diagrams illustrate the pile labeling convention and critical sections for checking shear capacity.

Uploaded by

Ehsan Sh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 7

Footing Pile Cap Design

Project : Footing Number : Engineer : Date :


1.Input Data SI-Units FPS-Units 5.Pile Arrangement
Column. width (b) = 0.6 m 23.6 in Required No. of Piles = 10.4
Column. depth (h) = 0.6 m 23.6 in Use number of total pile = 11.0
2.Material Properties X - direction FPS-Units Y - direction
number of row 3 number of column
number of pile on each row 4 number of pile on each column
Rebar fy = 420 Mpa 60.9 ksi spacing between pile 1.95 m 76.8 inch spacing between pile
spacing at edge of footing 0.65 m 25.6 inch spacing at edge of footing
Concrete fc' = 24 Mpa 3.5 ksi total length 7.15 m 281.5 inch total width
dx-1 1.95 m 76.8 inch dy-1
dx-2 0 m 0.0 inch dy-2
Modulus of Elasticity steel bars (Es) = 200,000 Mpa 29007.6 ksi 0.975
Modulus of Elasticity of Concrete (Ec) = 23,025 Mpa 3339.5 ksi
n = 9

3.Pile data (From Geo-Technical Report)


Pile diameter/width (D) = 0.65 m 25.6 in
safe load of pile (Capacity) = 800 KN 179.8 Kip
length of Pile (L) 14 m 551.2 in
4.Loadind Data
Axial Load (Px) = 0 KN 0.0 Kip
Axial Load (Py) 0 KN 0.0 Kip
Axial Load (Pz) 7,130 KN 1602.9 Kip
Mx = 85 KN-m 62.7 Kip-ft
My = 330 KN-m 243.4 Kip-ft
Mz = 0 KN-m 0.0 Kip-ft

4. Spring Constant or Point Spring (Kv)


Area of Cross Section of Pile (A) = 0.3318 m2 0.1 in2
Spring Constant (K=(EA/L) = 545,748 KN/m 3116.3 kip/in
Footing Pile Cap Design
Project : Footing Number : Engineer : Date :

Download

www.civilmdc.com
Footing Pile Cap Design
Project : Footing Number : Engineer : Date :
Type of Pile cap Footing can be used in this sheet
Y

- direction FPS-Units 11 12
4 X
3 21 22
1.95 m 76.8 inch
0.65 m 25.6 inch
5.2 m 204.7 inch
1.95 m 76.8 inch 11 12 13
0 m 0.0 inch X
21 22 23

11 12 13 14
X
21 22 23 24

11 12 13

21 22 23 X

31 32 33

11 12 13 14

21 22 23 24 X
31 32 33 34

Remarks
1 "dx" is the distance from the center of pile to the X-axis (parallel ot Y-axis)
2 "dy" is the distance from the center of pile to the Y-axis (parallel ot X-axis)
3 "d at X-dir" is the distance from the center of pile to the critical section on X-axis
4 "d at Y-dir" is the distance from the center of pile to the critical section on Y-axis
5 if d at X-dir or Y-dir are negative sign, it means that the pile is located inside the critical section
in other words, positive means outside
6 "arm X-dir" is distance in Y-dir to be induced moment about X-axis or Mx
7 "arm Y-dir" is distance in X-dir to be induced moment about Y-axis or My
8 reinforcement in X-dir must be determined by "My" and bar arrangement is located in X-dir
9 reinforcement in Y-dir must be determined by "Mx" and bar arrangement is located in Y-dir
10 input moment "Mx" have to be located in X-dir and always have greater values than "My"
11 when "actual distance" in subject "checking shear" is input, the "sign of the distance have to be check and input follow the "actual value"

3?
h/2 h/2+d/2
11 12 13 14 1?

dx b/2+d/2 3?
COL.
21 22 23 24
X b/2

for punching shear


d/2
d 31 32 33 34

for beam shear dy1


Y dy2