0% found this document useful (0 votes)
436 views

Unit 8 - Week 7: Assignment 7

This document provides 10 multiple choice questions testing understanding of unified power quality conditioners (UPQC). The questions cover topics like calculating voltage and VA ratings for different components of UPQC under various load and supply conditions like voltage sag/swell. Correct answers are also provided for self-evaluation.

Uploaded by

venugopal pudur
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
436 views

Unit 8 - Week 7: Assignment 7

This document provides 10 multiple choice questions testing understanding of unified power quality conditioners (UPQC). The questions cover topics like calculating voltage and VA ratings for different components of UPQC under various load and supply conditions like voltage sag/swell. Correct answers are also provided for self-evaluation.

Uploaded by

venugopal pudur
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Facts Devices - - Unit 8 - Week 7 https://onlinecourses.nptel.ac.in/noc18_ee44/un...

[email protected]

Courses » Facts Devices Announcements Course Ask a Question Progress Mentor FAQ

Unit 8 - Week 7

Course
outline
Assignment 7
The due date for submitting this assignment has passed.
How to access As per our records you have not submitted this Due on 2018-09-26, 23:59 IST.
the portal assignment.

Week 1 Each question has “1” mark and there is no negative mark
1) A single-phase unified power quality compensator (consisting of a DSTATCOM and a DVR 1 point
Week 2
using two VSCs with a common DC bus capacitor) is to be designed for a load of 230 V, 50 Hz, 25 A, 0.8
lagging power factor as a left-hand UPQC-Q, it used to provide reactive power compensation of the load
Week 3
for unity power factor at the AC mains with a constant regulated voltage of 230V at 50 Hz across the load.
Week 4 There is a voltage sag of -10% in the supply system with a base value of 230 V. Calculate the voltage rating
of the DVR (SSSC connected in distributed system )of the UPQC-Q,….
Week 5
49.32 V
Week 6
38.6 V

Week 7 44.3 V

UPQC 43.17 V
Introduction
and
No, the answer is incorrect.
Classification Score: 0

UPQC
Accepted Answers:
Classification - I 43.17 V

Operation and 2) In above question Q1, the total VA rating of the DVR of the UPQC-Q is …. 1 point
Control of
UPQC - II 1207.23 VA
Operation and 1079.25 VA
Control of
UPQC - III 984.25 VA
UPFC 921.4 VA
Quiz : No, the answer is incorrect.
Assignment 7
Score: 0
Solution for Accepted Answers:
Assignment - 7
1079.25 VA

© 2014 NPTEL - Privacy & Terms - Honor Code - FAQs -


A project of In association with

Funded by

1 of 4 Tuesday 16 October 2018 06:01 PM


Facts Devices - - Unit 8 - Week 7 https://onlinecourses.nptel.ac.in/noc18_ee44/un...

11.45 Powered
A by

No, the answer is incorrect.


Score: 0
Accepted Answers:
11.45 A

4) In above question Q1, Total VA rating of the UPQC-Q 1 point

2345.25 VA

1745.25 VA

4529.25 VA

5684.25 VA

No, the answer is incorrect.


Score: 0
Accepted Answers:
4529.25 VA

5) A single-phase unified power quality compensator (consisting of a DSTATCOM and a DVR 1 point
using two VSCs with a common DC bus capacitor) is to be designed for a load of 230 V, 50 Hz, 25 A, 0.8
lagging power factor as a left-hand UPQC-P, used to provide reactive power compensation for unity power
factor at the AC mains with a constant regulated voltage of 230V at 50 Hz across the load. There is a
voltage swell of +10% in the supply system with a base value of 230 V. Calculate the voltage rating of the
DVR of the UPQC-P,….

28.05 V

26.12 V

29.95 V

24.58 V

No, the answer is incorrect.


Score: 0
Accepted Answers:
28.05 V

6) In above question Q5, the total VA rating of the DVR of the UPQC-P is …. 1 point

1028 VA

701 VA

870 VA

685 VA

No, the answer is incorrect.


Score: 0
Accepted Answers:
701 VA

7) In above question Q5, The current rating of the DSTATCOM of the UPQC-P is …. 1 point

12.7 A

13.9 A

14.5 A

14.7 A

No, the answer is incorrect.

2 of 4 Tuesday 16 October 2018 06:01 PM


Facts Devices - - Unit 8 - Week 7 https://onlinecourses.nptel.ac.in/noc18_ee44/un...

Score: 0
Accepted Answers:
13.9 A

8) In above question Q5, Total VA rating of the UPQC-P 1 point

4496 VA

4296 VA

3296 VA

3496 VA

No, the answer is incorrect.


Score: 0
Accepted Answers:
4496 VA

9) A single-phase unified power quality compensator (consisting of a DSTATCOM and a DVR 1 point
using two VSCs with a common DC bus capacitor) is to be designed for a load of 230 V, 50 Hz, 25 A, 0.8
lagging power factor as a left-hand UPQC-Q used to t provide reactive power compensation of the load for
unity power factor at the AC mains with a constant regulated voltage of 230V at 50 Hz across the load.
There is a voltage swell of +10% in the supply system with a base value of 230 V. calculate the voltage
rating of the DVR of the UPQC-Q

32.13 V

34.12 V

35.64 V

36.58 V

No, the answer is incorrect.


Score: 0
Accepted Answers:
35.64 V

10)In above question Q9, VA rating of the DVR of the UPQC-Q is, 1 point

891.15 VA

981.31 VA

1032.42 VA

1123.45 VA

No, the answer is incorrect.


Score: 0
Accepted Answers:
891.15 VA

Previous Page End

3 of 4 Tuesday 16 October 2018 06:01 PM


Facts Devices - - Unit 8 - Week 7 https://onlinecourses.nptel.ac.in/noc18_ee44/un...

4 of 4 Tuesday 16 October 2018 06:01 PM