0% found this document useful (0 votes)
399 views8 pages

User Manual 88830539

The quick guide provides instructions for setting up and using the MultiHandy 2025 measuring instrument. It describes connecting sensors and accessories, operating the display and keys, setting the date and time, and connecting the device to HYDROcenter software for downloading measurements. The guide is a supplement to the full operating instructions and focuses on basic startup tasks for first-time users.

Uploaded by

David Gonzalez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
399 views8 pages

User Manual 88830539

The quick guide provides instructions for setting up and using the MultiHandy 2025 measuring instrument. It describes connecting sensors and accessories, operating the display and keys, setting the date and time, and connecting the device to HYDROcenter software for downloading measurements. The guide is a supplement to the full operating instructions and focuses on basic startup tasks for first-time users.

Uploaded by

David Gonzalez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

EN

MultiHandy 2025
Quick Guide

Version 1.0 EN
Firmware-Version 1.0
TKZ L3160-00-78.00EN
1 Description of the measuring instrument

Note 1.2 Measuring instrument


This Quick Guide is a supplement to the Operating
Instructions and is not a replacement for these.
• You can obtain the Operating Instructions via the
manufacturer's website
(HYDROTECHNIK.COM) or the HYDROcenter
software. A
• Observe the enclosed sheet on the General
Safety Information and Warnings.
B D
C
 To obtain the Operating Instructions with
HYDROcenter, see HYDROcenter, page 5.

1 DESCRIPTION OF THE MEASURING


INSTRUMENT
This section describes the scope of delivery, connec-
tions, keys and the display of the measuring instru-
ment.

A Display C Menu key


1.1 Measuring instrument case B Function keys D On/off button (F4)

The MultiHandy 2025 is a dual-channel measuring in-


strument which provides the user with all functions
needed for professional and challenging metrology.
The measuring instrument is operated via 4 function
keys and a menu key.
You can connect the measuring instrument to a PC
and charge it using the USB interface. We recom-
mend the HYDROlink6 software for downloading the
measurement data. Alternatively, you can use the
Measuring instrument case: HYDROcom6 software.
• 1 MultiHandy 2025
• 1 USB cable
• 1 power supply for USB cable with country adapter
• 2 ISDS pressure sensors with 2.5 m cable
Quick Guide • Version 1.0

• 2 MINIMESS direct connections


• 1 carrying strap set (including fastening eyelets)
• 1 Quick Guide
• 1 General Safety Informations and Warnings

1 MultiHandy 2025
1 Description of the measuring instrument

1.3 Connections 1.5 Keys, icons and functions

Switches instrument on.

Opens main menu.


Selects marked entry.
Switches display illumination on/off. EN
Switches instrument off (press for
A B 2 seconds).
Changes view:
C - Current measurement values
- Min./max. Measurement values
A Measurement channel 2 C USB interface
Sets zero point for all displayed chan-
B Measurement channel 1
nels.
Deletes all current min./max. measure-
1.4 Display ment values.
Starts the recording of a measurement
The display shows measurement values, menu en- series.
tries, status icons and function key icons. Stops the recording of a measurement
A B C D series.
Displays the memory status during re-
cording of measurements.
Scrolls down.

Scrolls up.

Selects the next entry.

Confirms the entry.

E F Interrupts the current process.


A ISDS icon E Function key icons
B Channel name Exits the menu.
Interrupts the current process.
C Measurement value F Status display
(battery/USB) Opens the menu for deleting measure-
D Unit of measurement
ment series.
Switches the view of the selected meas-
The measuring instrument shows the current meas- urement or special channel on or off.
urement values by default. [F1] / switches to the
Displays USB status:
min./max. measurement values.
• Instrument connected with USB.
If [F4] shows the lamp icon , the display illumina-
• Instrument is communicating via USB.
tion is switched on or off. Holding down the key
switches off the instrument. Displays battery status:
[MENU] displays the main menu. Full, half-full, empty.

2
2 Start-up

2 START-UP 4 Use [F1] to select your desired units of measure-


ment.
2.1 Charging measuring instrument Save your entry by pressing [F4].

The batteries of the measuring instrument must be


charged before it is switched on for the first time.

How to charge the measuring instrument


1 Remove the battery protective strips from the bat-
tery compartment.
2 Connect the country adapter for the respective
country to the USB power supply. The display shows the firmware version number
3 Connect the USB cable to the power supply. and serial number of the measuring instrument.
4 Plug the power supply into a socket. The display then shows the calibration notice.
5 Connect the USB cable to the measuring instru-
ment.
6 Let the measuring instrument battery charge unin-
terrupted for 12 hours.
7 Remove the USB cable from the measuring in-
strument.
8 Remove the power supply from the socket.

5 Use [F4] to exit the calibration notice.


2.2 Basic settings
After you have charged the measuring instrument,
you can switch it on. When you switch on the measur-
ing instrument for the first time, you are requested to
define the basic settings.

How to define the basic settings


1 Press [F4] to switch on the measuring instrument. The measuring instrument is ready.
2 Use [F1] or [F2] to select the desired menu lan-
guage.
Save your entry by pressing [F4].
Quick Guide • Version 1.0

3 Confirm your selection with [F3].

3 MultiHandy 2025
2 Start-up

2.3 Time and date 5 Press [F1] to select Date.


Use [MENU] to open the DATE MENU.
How to set the time and date 6 Set the date format and date:
1 Press [MENU] and use [F1] to select the Device • Use [F1] to select format or date and press
entry. [MENU].
Use [MENU] to open the DEVICE menu. • Press [F1] or [F2] to change the selected
value.
• Use [MENU] to save your entry. EN

2 Keep pressing [F1] until the Time entry is se-


lected.
Use [MENU] to open the CLOCK MENU. 7 Press [F4] until the display shows the measure-
ment values again.

3 Set the time format and time:


• Use [F1] to select format or time and press
[MENU].
• Press [F1] or [F2] to change the selected
value.
• Press [MENU] to save your entry.

4 Press [F4] to return to the DEVICE menu.

4
3 HYDROcenter

3 HYDROCENTER How to connect your measuring instrument to


HYDROcenter
HYDROcenter is a program for Windows. 1 Connect the USB cable to the USB interface of the
HYDROcenter is your centre for all instruments and measuring instrument.
software from HYDROTECHNIK. 2 Connect the other end of the USB cable to your
Install HYDROcenter to receive automatic updates for PC or notebook.
your measuring instrument as well as other software 3 Switch the measuring instrument on by pressing
(e.g. HYDROlink6). [F4].
4 Start the HYDROcenter program.
HYDROcenter detects the connected measuring
instrument and offers suitable downloads.

How to open the Operating Instructions


1 Click on the download icon next to the Manual
entry.

System requirements
You need a PC or notebook with Internet connection
and an operating system of Windows 7 or higher.
When the Operating Instructions are done down-
This is how you install the HYDROcenter software loading, it changes to the icon.
1 Enter the following text into the address bar of 2 Click on the open icon .
your Internet browser (e.g. Internet Explorer): The Operating Instructions are opened in your
http://hydrotechnik.com/hydrocenter PDF viewer.
You can save the Operating Instructions on your
PC or notebook.

2 Follow the instructions displayed there.


The installation file will be downloaded.
3 Run the installation file.
Confirm the confirmation prompts if applicable.
4 Follow the installation instructions.
The installation is complete when the link is dis-
played on the desktop.
Quick Guide • Version 1.0

5 MultiHandy 2025
4 Measurement

4 MEASUREMENT 4 Connect the MINIMESS direct connections of the


ISDS sensors to the selected MINIMESS testing
You can begin measurement immediately after start- points.
ing up the measuring instrument. 5 Switch the measuring instrument on by pressing
[F4].
If applicable, use [F4] to confirm the calibration
4.1 Measurement with ISDS sensors notice.
The ISDS sensors are detected by the measuring EN
How to perform measurements instrument. The display shows the current meas-
1 Find the MINIMESS testing point on your hydrau- urement values.
lic system.
Remove the protective caps from the MINIMESS
testing points you want to use to make measure-
ments.
2 Connect the ISDS sensors to the measuring in-
strument with the instrument switched off.

p1 displays the measurement value of the sensor


from channel 1 (CH1). Measurement unit [bar]
follows.
p2 stands for channel 2 (CH2).
dp (special channel) shows the difference be-
tween p1 and p2.

Zero adjustment
Press [F2] to execute a zero adjustment. The current
3 Connect the ISDS sensors with the MINIMESS di- measurement values are set to zero.
rect connections. Observe the following rules:
If necessary, remove the protective plastic cover- • Zero adjustment is applied to all displayed chan-
ing from the MINIMESS direct connections. nels.
Only tighten the thread manually. Do not use a • Zero adjustment cannot be undone.
tool. • Zero adjustment is only deactivated when you
switch off the measuring instrument.
• For safety reasons, a zero adjustment can only be
executed up to values of 1% of the maximum
measurement range.
With larger values, the display shows code 8110
and the maximum permissible values.
• A zero adjustment cannot be executed for chan-
nels showing a frequency.
• Measurement values are set to zero for channels
configured as counters.

6
4 Measurement

Min./max. Display 3 Start the measurement series by pressing [F3].


Pressing [F1] switches to min./max. display or back The display shows a progress bar on the right
to the current measurement values. side.
A B

4 Press [F2] to display the current memory status.

A Maximum values B Minimum values

Pressing [F2] deletes the min./max. memory. The dis-


play immediately shows the current min./max. meas-
urement values.

4.2 Recording and deleting measurement The display automatically switches back after
series 5 seconds. The measurement series automati-
cally ends after 60,000 measurement points.
You can save up to five measurement series. You can 5 Press [F3] to manually end the measurement se-
assess and save measurement series with the ries.
HYDROlink6 software.
If you have already saved five measurement values in How to delete a measurement series
the measuring instrument, you must delete measure- 1 Press [MENU] to open the MAIN MENU.
ment series before you can save new measurement 2 Press [F1] to select the Memory entry and use
series. [MENU] to open the MEMORY menu.
3 Press [F1] or [F2] to select a measurement series
How to save a measurement series of all: #1 - #5.
1 Press [F3].
2 If necessary, change the Scanrate using
[MENU].

4 Press [F3] and confirm with [F4].


Quick Guide • Version 1.0

The selected measurement series are deleted.


5 Press [F4] until the display shows the measure-
ment values again.

7 MultiHandy 2025

You might also like