0% found this document useful (0 votes)
475 views4 pages

PCS 7 Version Software Simatic Pcs 7 V8

PCS 7 V8.0 is compatible with V7.x, V6.x, V5.x and V4.x of various PCS 7 software components. Some specific versions it is compatible with include: S7-SCL V5.3 SP6, PCS 7 Library V7.1 SP3, and PCS 7 Advanced Process Library V7.1 SP5 Upd2. PCS 7 V8.0 also requires compatible versions of Microsoft Windows, Office, SQL Server and other third-party software.

Uploaded by

Jaime Montes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
475 views4 pages

PCS 7 Version Software Simatic Pcs 7 V8

PCS 7 V8.0 is compatible with V7.x, V6.x, V5.x and V4.x of various PCS 7 software components. Some specific versions it is compatible with include: S7-SCL V5.3 SP6, PCS 7 Library V7.1 SP3, and PCS 7 Advanced Process Library V7.1 SP5 Upd2. PCS 7 V8.0 also requires compatible versions of Microsoft Windows, Office, SQL Server and other third-party software.

Uploaded by

Jaime Montes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

s With what are SIMATIC PCS 7 V7.x, V 6.x, V5.x and V4.x compatible?

Entry-ID: 2334224

PCS 7 Version SIMATIC PCS 7 V8


Software V8.0 V8.0 Upd1
7 SP1 (Ultimate) x x
XP Embedded Standard 2009 *11) x x
XP Professional SP3 x x
Microsoft Windows Server 2003 SP2 (Standard Edition) x x
(32-Bit) Server 2003 R2 SP2
x x
(Standard Edition) *1)
Server 2008 SP2
x x
(Standard Edition)
7 SP1 (Ultimate) x x
Microsoft Windows
Server 2008 R2 SP1
(64-Bit) x x
(Standard Edition)
Windows Firewall all x x
*9)
2003 SP3 x x
2007 SP2 x
2007 SP3 x
Microsoft Office
2010 SP1 x x
(32-Bit)
Word Viewer 2003 SP3 x x
Excel Viewer 2007 SP2 x x
Powerpoint Viewer 2010 x x
V2.0 SP2 x x
V3.0 SP2 x x
Microsoft .NET
V3.5 SP1 x x
V4.0 x x
Microsoft Internet Explorer V7.0 *6) x x
*2)
V8.0 *7) x x
2005 SP4 x x
Microsoft SQL Server *8)
2008 R2 SP1 x x
Trend Micro OfficeScan
x
Client-Server Suite V10.5 HF1946
Trend Micro OfficeScan
x
Client-Server Suite V10.6
McAfee VirusScan Enterprise V8.8 x
Virus Scanner McAfee VirusScan Enterprise V8.8
x x
Patch1
McAfee VirusScan Enterprise V8.8
x
Patch1 Hotfix 735512
Symantec Endpoint Protection
x x
V11.0 *19)
Application Whitelisting McAfee Application Control V5.1 x x
RDP (Remote Desktop Protocol) x *16) x *16)
Remote Software "RealVNC" Enterprise Edition V4.6 x
"RealVNC" Enterprise Edition V4.6.3 x x
PDF Reader PDF 1.7 (ISO32000-1:2008 PDF). x x
V5.1 SP1 Upd1 x
Automation License
V5.1 SP1 Upd2 x
Manager
V5.1 SP1 Upd3 x x
V5.5 SP2 x
Step 7 Basis *3) V5.5 SP2 Upd1 x
V5.5 SP2 Upd4 x

This entry is from the Service&Support portal of Siemens AG,


Change date: Sector Industry, Industry Automation and Drive Technologies. Page: 1/4
05.12.2012 The general terms of use (http://www.siemens.com/terms_of_use) apply.
s With what are SIMATIC PCS 7 V7.x, V 6.x, V5.x and V4.x compatible? Entry-ID: 2334224

PCS 7 Version SIMATIC PCS 7 V8


Software V8.0 V8.0 Upd1
V8.0 x
V8.0 Upd1 x
CFC
V8.0 SP1 x
V8.0 SP2 x
S7-SCL V5.3 SP6 x x
V8.0 x x
SFC
V8.0 Upd1 x
V8.0 x
TH V8.0 Upd1 x
V8.0 Upd2 x
V8.0 x
IEA-PO
V8.0 Upd1 x
V6.1 SP1 HF17 x
PCS 7 Library
V7.1 SP3 x x
V7.1 SP5 Upd2 x
PCS 7 Advanced Process V7.1 SP5 Upd3 x x
Library V8.0 x
V8.0 Upd1 x x
V7.1 SP3 Upd5 x
V7.1 SP3 Upd6 x x
V8.0 x
PCS 7 Basis Library
V8.0 Upd1 x
V8.0 Upd2 x x
V8.0 Upd3 x
PCS 7 Industry Library V8.0 x
VersionCrossManager V7.1 SP3 x x
Version Trail V8.0 x x
PCS 7 PID Tuner V8.0 x x
DOCPRO V5.4 SP2 x x
PLCSIM V5.4 SP5 Upd1 x x
V7.0 SP3 x
SIMATIC WinCC V7.0 SP3 Upd1 x
V7.0 SP3 Upd2 x
V7.0 SP3 x
PCS 7 OS WebOption V7.0 SP3 Upd1 x
V7.0 SP3 Upd2 x
V7.0 SP3 x
DataMonitor V7.0 SP3 Upd1 x
V7.0 SP3 Upd2 x
V7.0 SP3 x
StoragePlus V7.0 SP3 Upd1 x
V7.0 SP3 Upd2 x
V8.0 x
Process Historian
V8.0 Upd1 x
V8.0 x
Information Server
V8.0 Upd1 x
V7.0 SP3 x
Connectivity Pack
V7.0 SP3 Upd2 x
V8.0 x
Open PCS 7 V8.0 Upd2 x
V8.0 Upd4 x

This entry is from the Service&Support portal of Siemens AG,


Change date: Sector Industry, Industry Automation and Drive Technologies. Page: 2/4
05.12.2012 The general terms of use (http://www.siemens.com/terms_of_use) apply.
s With what are SIMATIC PCS 7 V7.x, V 6.x, V5.x and V4.x compatible? Entry-ID: 2334224

PCS 7 Version SIMATIC PCS 7 V8


Software V8.0 V8.0 Upd1
V8.0 x x
SFC Visualization
V8.0 Upd1 x
V8.0 x
AS-OS-Engineering
V8.0 Upd1 x
PCS 7 Advanced
V8.0 x x
Engineering System
PV InsInfo Server V8.0 x x
PCS 7 Faceplates V7.1 SP3 x x
PCS 7 Advanced V8.0 x
Faceplates V8.0 Upd1 x
V8.0 x
PCS 7 Basis Faceplates
V8.0 Upd1 x
V7.1 SP4 x
V7.1 SP5 x
SIMATIC NET PCSW *4)
V8.1 SP1 x
V8.1 SP2 x
V8.0 x
SIMATIC BATCH
V8.0 Upd1 x
V8.0 x
SIMATIC BATCH BLOCKS
V8.0 Upd1 x
V1.5 x
SIMATIC Logon
V1.5 Upd1 x
V6.1 x
*10) V8.0 x
SIMATIC PDM
V8.0 Upd1 x x
V8.0 SP1 Upd3 x
V8.0 x
SIMATIC Route Control
V8.0 Upd1 x
PCS 7 System
V8.0 x x
Documentation
V8.0 x
PCS 7 Tools
V8.0 Upd1 x
*5) V6.0 *17) x
S7 F Systems
V6.1 SP1 x x
V6.1 SP1 *17) x
Safety Matrix
V6.2 SP1 x x
*15) V7.1 SP1 x x
Drive ES PCS 7
V8.0 x x
*12)
V5.4 SP5 x x *12)
*15)
Drive ES Basic V5.5 x *12) x *12)
V5.5 SP1 x *12) x *12)
SIMATIC powerrate V4.0 SP1 x
V5.2 SP1 x
SIMATIC B.Data *14)
V5.3 x
SIMATIC PCS 7
V8.0 x
TeleControl
SIMATIC PCS 7
V8.0 x
PowerControl
SIMATIC SIPAT V4.0 x
BATCH Report V7.0+SP1+HF15 x x
DCF77Client V2.0 x x

This entry is from the Service&Support portal of Siemens AG,


Change date: Sector Industry, Industry Automation and Drive Technologies. Page: 3/4
05.12.2012 The general terms of use (http://www.siemens.com/terms_of_use) apply.
s With what are SIMATIC PCS 7 V7.x, V 6.x, V5.x and V4.x compatible? Entry-ID: 2334224

PCS 7 Version SIMATIC PCS 7 V8


Software V8.0 V8.0 Upd1
V4.3 SP1 HF2 x
DiagnoseMonitor V4.3 SP2 x
V4.3 SP3 x
MS_HTML_HelpGen_for_P
V4.74.8703 x x
DM
S7 Block Privacy V1.0 SP1 Upd1 x x
PKZIP V12.4 x x
V4.0 x x
WinAC SLOT
V4.0 incl. WinAC TimeSync V4.1 x x
V4.4 SP1 HF1 x
WinAC_RTX V4.6 x
V4.6 Upd2 x x
WinCC Archive
V7.0 SP3 x x
Configuration Tool
2008 SP2 Upd13 x
WinCC flexible *20)
2008 SP3 x
WinCC_Fileserver V7.0 SP3 x x
WinCC WebNavigator V7.0 SP3 x x
SIMATIC Diagnose Tool SDT_2011_1 x x

*1) If the operating system is installed on the basis of Windows Server 2003 R2, please note
strictly the advices in the "readme" file of your PCS 7 version.
*2) It is necessary to use the version of the Internet Explorer which is integrated in the
released operating system everytime.
*3) Notice operating system, entry 8250891
*4) Notice operating system, entry 9859007
*5) Notice operating system, entry 16537972 and use
S7 F ConfigurationPack >= V5.5 SP9 (Entry 15208817)
*6) For Windows XP and Windows Server 2003 only Internet Explorer V7.0 is released.
*7) For Windows 7 and Windows Server 2008 only Internet Explorer V8.0 is released.
*8) The valid version of SQL-Server will be automatically installed from PCS 7 setup.
*9)
Microsoft Office 2003 SP3 is only released for Windows XP and Windows Server 2003.
*10) Look for SIMATIC PDM Devices under the following link: https://www.siemens.de/simatic-
pdm.
*11) Windows XP Embedded Standard 2009 is only released for PCS 7 AS RTX, S7-mEC
and HMI Thin Client.
*12) The DCC functionality inside STARTER is not released yet.
*13) It is recommended to use the "Corporate Edition" of Trend Micro OfficeScan
virusscanner on a PCS 7 computer.
*14) On the part of configuration it is necessary to install the B.Data system on a separate
PC.
*15) Notice operating system, entry 18495518
*16) Only via a console session.
*17) Only released for Windows XP Professional SP3 and Windows Server 2003
*18) It is recommended to use the "Corporate Edition" of Trend Micro OfficeScan
virusscanner on a PCS 7 computer.
*19) 64-Bit operating systems (Windows 7 / Windows Server 2008 R2) are only
recommended with V11.0.7000.975 or higher.
*20) Notice operating system, entry 22055368

This entry is from the Service&Support portal of Siemens AG,


Change date: Sector Industry, Industry Automation and Drive Technologies. Page: 4/4
05.12.2012 The general terms of use (http://www.siemens.com/terms_of_use) apply.