0% found this document useful (0 votes)
196 views1 page

P101 - Restroom Plumbing Plan

The document provides general notes for a plumbing plan. It specifies that all waste piping and fittings are to be made of PVC, Type DWV or Schedule 80 PVC. Underground piping must be installed with a minimum of 800mm of cover. All water pipes must be insulated with mineral fiber or flexible elastomeric insulation with a vapor retarder. All sizes and dimensions are in millimeters unless otherwise noted, and sanitary waste piping must pitch at a minimum of 1.5% unless specified otherwise.

Uploaded by

LiaqatSrak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
196 views1 page

P101 - Restroom Plumbing Plan

The document provides general notes for a plumbing plan. It specifies that all waste piping and fittings are to be made of PVC, Type DWV or Schedule 80 PVC. Underground piping must be installed with a minimum of 800mm of cover. All water pipes must be insulated with mineral fiber or flexible elastomeric insulation with a vapor retarder. All sizes and dimensions are in millimeters unless otherwise noted, and sanitary waste piping must pitch at a minimum of 1.5% unless specified otherwise.

Uploaded by

LiaqatSrak
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GENERAL NOTES:

1. ALL WASTE PIPING AND FITTINGS TO


BE ASTM D2665 PVC, TYPE DWV.

2. ALL DOMESTIC WATER PIPING SHALL


BE OF SCHEDULE 80 PVC.
25 mmø 25 mmø 50 mmø-50 15 mmø
UNDERGROUND PIPING SHALL BE
mmø
INSTALLED WITH MIN. 800mm COVER.
80 mmø
3. ALL WATER PIPES TO BE INSULATED
WITH 25mm MINERAL FIBER
PREFORMED INSULATION OR 20mm
25 mmø 25 mmø FIEXIBLE ELASTOMERIC INSULATION
50 mmø-50 WITH VAPOR RETARDER.
50 mmø

25 mmø
mmø-50 50 mm
CONNECT TO mmø CLEANOUT 4. ALL SIZES AND DIMENSIONS ARE
SITE SHOWN IN MILLIMETERS (mm)

50 mmø
DRAINAGE UNLESS OTHERWISE NOTED.

5. ALL SANITARY WASTE PIPING SHALL


25 mmø

PITCH A MINIMUM OF 1.5%, UNLESS


NOTED OTHERWISE.

50 mmø

WH
FROM DOMESTIC FLOOR DRAIN
WATER SUPPLY 40 mmø
SYSTEM
100 mm
100 CLEANOUT
CONNECT TO mmø-100
SANITARY mmø-100
COLLECTION mmø
SYSTEM
100 mm VENT

100 mmø
THROUGH ROOF
100 mmø

100 mmø
100 mmø 100 mmø 100 mmø 100 mmø
25 mmø

100 mm P-Trap

25 mmø 25 mmø 15 mmø

1 - Plumbing
1 1 : 25

No. Description Date


RESTROOM PLUMBING PLAN

11/3/2020 11:03:02 PM
Project number -----------
Date ----------
P101
Drawn by Author
PRUNE PROCESSING COMPLEX
Checked by Checker Scale 1 : 25