CKD V3301series
CKD V3301series
3 (R) 3 (R)
V3301 V3321
Specifications
Descriptions V3301-W/V3321-W
Operating method Pilot operated soft spool valve
Working fluid Compressed air (excluding super dry air) Note 1
Working pressure range MPa 0.2 to 1.0
Withstanding pressure MPa 1.5
Ambient temperature range 5 to 60
1 (P), 2 (A) port Rc1/4 Rc3/8 Rc1/2
Port size 3 (R) port Rc3/8
Gauge port Rc1/4
Low speed intake 6
Effective sectional area
High speed intake 40 64 76
mm2
High speed exhaust 50 74 78
Response time 0.2sec or less
Lubrication Oil-free Note 2
Weight g V3301-W: 635 V3321-W: 515
Solenoid valve specification V3301-W
Rated voltage V AC100 (50/60Hz) AC200 (50/60Hz) DC24
Starting current A 0.076/0.058 0.038/0.030
0.092
Holding current A 0.038/0.029 0.019/0.015
Power consumption W 2.2/1.7 2.2/1.7 2.2
Temperature increase K 40 or less
Voltage fluctuation range 10%
Insulation class B class
Electric connection Grommet lead wire, terminal box
Note 1: Contact CKD when using ultra dry compressed air.
Note 2: Use the turbine oil Class 1 ISO VG32 if lubricated. Symbol Descriptions
A Port size
How to order 1 (P), 2 (A) port
08 Rc1/4
Solenoid valve V3301 8 W 1 BW 10 Rc3/8
(White type)
15 Rc1/2
Manual V3321 8 W BW B Manual override
A Port size Blank Non-locking type
B Manual override M1 Locking type
C Electric connection
C Electric connection
Blank Grommet lead wire
S Grommet lead wire with surge supressor
B Terminal box
LS Terminal box surge supressor with lamp
D Voltage
D Voltage
1 AC100V 50/60Hz
Standard
Select the reverse regulator (R*100-W) or reverse filter 2 AC200V 50/60Hz
regulator (W*100-W) when installing the V3301-W or 3 DC24V
V3321-W onto the primary side of the regulator or filter 4 DC12V
regulator. Option
5 AC110V 50/60Hz
6 AC220V 50/60Hz
149
V3301-W V3321-W Series
Dimensions
Dimensions
V3301-W Bracket: B320
63 67
51
18
50
7
53
(63) 45
Pg9
45
Lead wire
Length 300mm
86
44
1 (P) 2 (A)
(103)
2-A
ø43.5
3 (R)
B 2-C
A B C
V3301-08-W Rc1/4
V3301-10-W Rc3/8 Rc3/8 Rc1/4
V3301-15-W Rc1/2
63
58
50
60
ø25
(63) 45
6
82
133
1 (P) 2 (A)
(103)
2-A
3 (R)
B 2-C
A B C
V3321-08-W Rc1/4
V3321-10-W Rc3/8 Rc3/8 Rc1/4
V3321-15-W Rc1/2
150
V3301-W / V3321-W Series
Operational explanation (refer to operating principles)
The slow start valve turns on when the solenoid valve is energized or the Operational properties
manual section is set to SUP. The valve turns off when the solenoid valve ON OFF
is deenergized or the manual section is set to EXH. When pressurizing High speed exhaust
(1) First, when the main unit is turned on, the low-speed supply path
Low speed intake High speed intake
opens, and the compressed air starts to flow to the secondary side.
P2=P1
Pressure loss
The secondary pressure gradually starts to rise. The operable
cylinders in the unit will start moving at a low speed and thus will not P2=P1×0.6
pop out.
P2
(2) Next, when secondary pressure exceeds 60% of primary pressure, Switchover secondary pressure
the hight speed supply path opens. Secondary pressure suddenly
rises tot he same pressure as primary pressure. (fully open) Time t
(3) When the main unit is turned OFF, high speed exhaust starts and
residual pressure in the unit is exhausted. Switchover secondary pressure
0.4
0.2
P2
(MPa)
0
0 0.2 0.4 0.6 0.8 1.0
Primary pressure P1 (MPa)
Safety precautions
Note 1: T his valve is dedicated for starting and stopping (including
emergency stop) the device. This valve should not be used for
cylinder repeat operation or as a normal 3-way valve.
Note 2: If the minimum operating pressure of the cylinder, which is to be
kept from popping out, is less than 50% of the working pressure,
popping out will not be prevented.
Note 3: The manual override is locked with the manual valve type. Select
a padlock with a D dimension of 3.8 to 5.8 mm.
Note 4: Connect a silencer or exhaust filter, etc., to the exhaust port for
safety and sound absorption.
151