0% found this document useful (0 votes)
167 views23 pages

A Quick and Easy Way To Connect To F Fieldbus Using Emerson's USB Fieldbus Interface

The document describes Emerson's USB Fieldbus Interface, which allows a standard PC or laptop to connect to a FOUNDATION fieldbus segment. It was originally developed internally by Rosemount but is now being commercialized by Emerson. The interface provides power to the segment, includes two fieldbus terminators, and indicates communication and power status. It works with AMS Device Manager software to access fieldbus devices and their data. The interface, cable, manual, and utility software allow basic commissioning and monitoring of devices connected to the segment from a laptop.

Uploaded by

samim_kh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
167 views23 pages

A Quick and Easy Way To Connect To F Fieldbus Using Emerson's USB Fieldbus Interface

The document describes Emerson's USB Fieldbus Interface, which allows a standard PC or laptop to connect to a FOUNDATION fieldbus segment. It was originally developed internally by Rosemount but is now being commercialized by Emerson. The interface provides power to the segment, includes two fieldbus terminators, and indicates communication and power status. It works with AMS Device Manager software to access fieldbus devices and their data. The interface, cable, manual, and utility software allow basic commissioning and monitoring of devices connected to the segment from a laptop.

Uploaded by

samim_kh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 23

A Quick and Easy Way

to Connect to
FOUNDATION fieldbus
using Emerson’s USB
Fieldbus Interface

Emerson User Exchange, 2011


Nashville, TN
Presenters

 Alan Dewey
Introduction

 Background
 Features
 Using with AMS Device Manager
 Utility Program
 Packaging
 Fieldbus Foundation Profiles
 Demonstration
Background

 Originally available
internally from Rosemount
as 770

 Original objective was to


help Rosemount sales
force demonstrate
FOUNDATION fieldbus
devices
“Productizing” by Emerson AO
 Packaging
 Enhancements to Utility

 Official Device Manager Support

 Documentation

 Pricing

 Support

 Agency Approvals

 Additional Testing and Beta Testing


Objective of Product

 Provide a convenient means to connect a standard


PC or laptop computer to a FOUNDATION fieldbus
segment.

 Not intended to be used to implement a permanent


fieldbus Host system.
Features
 Fully compliant with FF Specifications
 Joins the fieldbus segment as a Visitor
 Two Power Modes
– USB provides power to FF segment (85 ma)
– Use with segments that are already powered
 Provides two Fieldbus terminators for segment
 Does not draw more than 12 ma from FF Segment
 CE and UL/CSA Approval
 Indicator lights for communication and power
 Uses standard USB cable
 Uses standard leadset (like the 475 Field Communicator)
Power Mode Handling

No Power Detected Power Detected on USB is Providing


Segment Power (will not be
allowed if power
Default Case
detected).
Approvals

IEC 61626-1 EMC IEC 60950-1

Immunity IEC/UL/CSA

Safety Approvals

Also:

FCC 47CFR
FF Physical Layer Test
Use with AMS Device Manager - Simple
Full Featured Device Dashboard Displays
Deployment with AMS Device Manager

 Supported starting with Version 11.5 of AMS Device


Manager

 Shows up under the “FF HSE” branch

 Requires AMS Device Manager HSE License


– Special Pricing Available

 Consistent Functionality with other FF interfaces


supported in AMS Device Manager
Utility Program Features

 Sets Power Mode


 Show Devices Connected to the segment
 Allows User to:
– Set the Device Tag
– Set the Device Address
Not provided in
– Commission / Decommission a Device AMS Device Manager
– Change Device from Link Master to Basic

 Provided on CD with product


Utility Program Display – Simple!

Address of USB Interface Indicates that segment is


One Device on Segment
on FF Segment already powered.
(TT-101)
Utility Program Display – Simple!

Select this if you want laptop to


A message warns you not to
connect power to segment that is
provide power to the segment via already powered.

USB.
Utility Program Display – Simple!

Simply Select this to


commission device Enter Device Tag Here. Device Address will be
selected automatically or
can be entered.
Future Supported Applications

 Rosemount Radar Master

 Fisher Valvelink
Product Positioning
Packaging

 Interface Module

 USB Cable

 Fieldbus Lead Set

 Installation CD

 User Manual
Fieldbus Foundation Profile Coverage

USB Fieldbus Interface (with AMS Device

Manager) will initially conform to this profile


Summary

 The previous Rosemount 770 Fieldbus Modem is


now available as the USB Fieldbus Interface to
customers.

 Extend your laptop with AMS Device Manager


beyond HART to FOUNDATION fieldbus devices
Where To Get More Information

AMS Device Manager Web Site


Expected Release Date – Spring, 2012.