MFS Web 16o
MFS Web 16o
Features:
Simple methods for introducing controlled and calibrated faults.
Study the vibration spectra of common faults, learn fault signatures and validate
rules provided in training courses.
Bench top machine for hands-on training and skill sharpening.
Learn machine condition monitoring and predictive maintenance.
Manual with exercises for individually paced study.
Modular, versatile, robust, and comprehensive.
Simultaneous reciprocating and rotating mechanisms.
Learn resonance, variable speed, gearbox, and belt drive diagnostics.
Learn to determine vibration transmission path and perform root-cause analysis.
Study correlation among vibration, motor current, and noise spectra.
Model rotor dynamics and its effects on fault signatures.
Validate balancing procedures above and below the first critical resonance.
The Best Tool Available for Learning Machinery Diagnosis
To gain an in-depth understanding of different vibration signatures, controlled experiments on
a device that emulates real world machinery are needed. While analysis of a single
machinery fault may be beneficial, there are many occasions when the analysis of the
interaction between dynamic stiffness, resonance, and speed is essential in order to gain an
understanding of real world vibration spectra.
With the MFS, the expertise required to diagnose industrial machinery problems in well
controlled experiments can be developed and enhanced. With a plant running at full
production, it is virtually impractical to gain an understanding of the kinetics and dynamics of
machinery without adversely affecting production and profits: The MFS enables offline
training and experimentation which in turn will minimize production downtime.
Basic MFS
Configuration and
Option Kits
The MFS provides a basic
setup for performing
experiments and learning
vibration signatures of
different machine
malfunctions. However, a
detailed investigation of
particular and more
advance vibration
phenomena or machinery
fault will require additional
attachments and fixtures
which are available
through optional kits.
Multi-Belt Drive, Straight Tooth Gearbox, and Adjustable Particle Magnetic Brake System
(M-BDGB)
Learn sheave misalignment and belt tension effects on vibration, and belt
fault frequencies.
Learn the effects of load, backlash, and tooth faults on the amplitudes and
distribution of the gearmesh and sideband frequencies.
Develop advanced signal processing techniques such as time synchronous
averaging, wavelet analysis, short time Fourier transform for gearbox fault
diagnosis.
Develop expertise to diagnose a gearbox problem under a variable loading
(or speed) conditions.
Learn the effects of the frequency and amplitude modulation on vibration
spectra.
Remove the pinion assembly for backlash adjustment, and fault
introduction.
The kit consists of two V-belts, two double groove sheaves and one rolling tensioner; one three-
way oil-lubricated gearbox with straight cut bevel gears, cup and cone roller bearings; and one
manually adjustable magnetic braking system.
Eccentric Sheave (M-ES-3/4)
Study the effects of eccentric sheaves.
Distinguish between eccentricity, unbalance, belt resonance.
The kit consists of one eccentric sheave.
Requires M-BDGB
The MFS is made of precision machined parts and designed for easy
upgrades and customization
Turnkey Package
SpectraQuest simulators and software are conveniently sold as comprehensive training packages. The purchase
of a training package provides you with all of the components necessary, such as sensors, data acquisition and
analysis software, for a fully functional, turnkey training system.
Turn your present engineers into vibration experts
Accurate machinery problem assessment and identification as to root cause
Improve process and machinery reliability and satisfy ISO and QS expectations
Practice and experiment in laboratory environment to accelerate the learning process
Turnkey Training Package 4 : Vibration Study Complete system for in-depth studies of alignment, balancing,
resonance, bearing defect, gearbox & belt drive fault, reciprocating mechanism, mechanical rub, shaft/rotor crack
and damping issues. Includes: MFS (MFS2010-PK4) eight accelerometers (SQI604/8), one tri-axial
accelerometer (SQI482A05), 8 channel desktop DAQ (VQ-DT8)
Turnkey Training Package 5F: Vibration Study Complete system for in-depth studies of alignment, balancing,
resonance, bearing defect, gearbox & belt drive fault, reciprocating mechanism, mechanical rub, shaft/rotor crack,
damping. Includes: MFS (MFS2010-PK6), eight accelerometers (SQI604/8), two tri-axial accelerometers
(SQI482A05), AC motor current probe (SQICP1), 8 channel desktop DAQ (VQ-DT8)
Machinery Fault Simulator (MFS)
Specifications
Electrical
Shaft Diameter 3/4” diameter; Turned, Ground, & Polished (TGP) steel
Bearing Two sealed rolling element in aluminum horizontally split bracket housing for
easy changes, tapped for transducer mount. Bearing mounts can be mounted
in five different position for variable rotor span
Rotor Base 18” long, completely movable using jack bolts for easy horizontal misalignment
and standard shims for vertical misalignment. Pinned for easy realignment.
Rotors Two 6” aluminum with 36 threaded holes at 10 degree intervals for introducing
unbalance
Belt Mechanism Two double groove “V” belt with one set screw mounting and one bush/key
mounting. Positive displacement lever with turnbuckle plus adjustable gearbox
platform
Gearbox and Brake Accessible three-way straight cut bevel gearbox with 1.5:1 ratio (20 gear input).
Manually adjustable magnetic brake 0.5 - 10 lb.-in
Reciprocating Mechanism Adjustable spring engagement timing and two stroke settings.
Centrifugal Pump ½ HP, 27psi at 0gpm, 25gpm at 0psi with water at 4000rpm
Reciprocating Compressor ½ HP, 2.6cfm, 120psi belt driven with 5-gallon air tank
Instrumentation Connectors 16 BNC connector plate under the rotor base linked to BNC connector panel
mounted on the edge for the base plate for direct connection to data collectors
Safety Cover Lockable clear, impact resistant hinged plastic cover with motor interlock switch
to shut down motor when cover is raised
Foundation 1/2” (12.7 mm) die cast aluminum base, base stiffener and eight rubber
isolators
Physical