Ceiling Specification Sheet

Project Title: _______________________________________


Client Name: ___________________________
Date: ____________________________________

Item Name: ACOUSTIBuilt Seamless Acoustical Ceiling Finish(es): White Fine Texture
System Unit sold as: _(ft2, lineal ft., gallon, metric units also apply)
Manufacturer: Armstrong Ceilings Size / Dimensions: 48 in x 72 in
Mfr. Number: _________________________________ Weight:
Contact Information: ___________________________ Color: White
Item Description: New seamless acoustical ceiling and Quantity:
wall system that looks like drywall, but offers the
performance of TOTAL ACOUSTICS.

TAG: Room Number/Space: West Wing Second Floor


Special Instructions / Notes:

Standard/Testing: Up to 0.80 NRC/ CAC 46, Sag/Humidity


Resistance

Certification/Test: Fire Performance rating Class A (UL), USDA


certified biobased content

Selling Price each ___________ x Quantity _____ $N/A


Installation charge $N/A
Packing / Storage charges $N/A
Total Selling Price for this sheet. $N/A

ALIYAH GRAY

1|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

SECTION 09 50 00

09 54 00 Integrated Ceiling Assemblies

PART 1 – GENERAL

1.1 RELATED DOCUMENTS

Drawings and general conditions of Contract, including General and Supplementary Conditions and Divisions-1
Specification sections apply to work of this section.

1.2 SUMMARY

a) Section Includes
1) Acoustical ceiling panel
2) Wire hangers, fasteners, main runners, cross tees, and wall angle moldings
3) Perimeter Trim
b) Related Sections
1)Section 09 51 13 - Acoustical Fabric-Faced Panel Ceilings
2)Section 09 53 00 - Acoustical Ceiling Suspension Assemblies
3)Section 09 83 00 – Acoustical Finish
4)Section 09 20 00 - Plaster and Gypsum Board
5)Section 09 22 16 - Non-Structural Metal Framing
6)Section 01 81 13 - Sustainable Design Requirements
7)Section 01 81 19 - Indoor Air Quality Requirements
8)Section 02 42 00 - Removal and Salvage of Construction Materials
9)Divisions 23 - HVAC Air Distribution
10) Division 26 - Electrical
c) Alternates
1)Prior Approval: Unless otherwise provided for in the Contract documents, submit proposed product
substitutions no later than TEN (10) working days prior to the date established for receipt of bids.
Acceptability of a proposed substitution is contingent upon the Architect’s review and acceptance. Approved
products will be set forth by the Addenda. If a substitution is included in a Bid and is not approved by an
Addendum, the specified products shall be provided as in place of the substitute without additional
compensation.

2|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

2)Submittals that do not provide adequate data for the product evaluation will not be considered. The
proposed substitution must meet all requirements of this section, including but not necessarily limited to,
the following: Single source materials suppliers (if specified in Section 1.5); Underwriters' Laboratories
Classified Acoustical performance; Panel design, size, composition, color, and finish; Suspension system
component profiles and sizes; Compliance with the referenced standards.

1.3 REFERENCES

a) American Society for Testing and Materials (ASTM):


1) ASTM A 1008 Standard Specification for Steel, Sheet, Cold Rolled, Carbon, Structural, High-Strength Low-
Alloy and High-Strength Low-Alloy with Improved Formability
2) ASTM A 641 Standard Specification for Zinc-Coated (Galvanized) Carbon Steel Wire
3) ASTM A 653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process
4) ASTM C 645 Standard Specification for Metal Suspension Systems
5) ASTM C 636 Recommended Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile
and Lay-in Panels
6) ASTM C754 AND C1858 All installations should be in compliance with these tests.
7) ASTM D 3273 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings
in an Environmental Chamber
8) ASTM E 84 Standard Test Method for Surface Burning Characteristics of Building Materials
9) ASTM E 580 Installation of Metal Suspension Systems in Areas Requiring Moderate Seismic Restraint
10) ASTM C 423 Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
11) ASTM E 1414 Standard Test Method for Airborne Sound Attenuation between Rooms Sharing a Common
Ceiling Plenum
12) ASTM E 1264 Classification for Acoustical Ceiling Products
13) ASTM E3090 All references to suspension component property testing per this test method.
b) B. International Building Code
c) C. ASHRAE Standard 62.1-2004, Ventilation for Acceptable Indoor Air Quality
d) D. NFPA 70 National Electrical Code
e) E. ASCE 7 American Society of Civil Engineers, Minimum Design Loads for Buildings and Other Structures
f) International Code Council-Evaluation Services - AC 156 Acceptance Criteria for Seismic Qualification Testing of
Non-structural Components
g) International Code Council-Evaluation Services Report - Seismic Engineer Report
a. 1. ESR 1289 - Armstrong Suspension Systems
h) California Department of Public Health CDPH/EHLB Emission Standard Method Version 1.1 2010
i) LEED - Leadership in Energy and Environmental Design is a set of rating systems for the design, construction,
operation, and maintenance of green buildings
j) International Well Building Standard
3|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

k) Mindful Materials
l) Living Building Challenge

1.4 SYSTEM DESCRIPTION

Continuous/Wall-to-Wall or Cloud installation

1.5 SUBMITTALS

a) Shop Drawings: Layout and details of ceilings. Show locations of items that are to be coordinated with, or
supported by the ceilings.
b) Installation Instructions: Submit manufacturer’s installation instructions as referenced in Part three,
Installation.
c) Product Data: Submit manufacturer’s technical data for each type of ceiling unit and suspension system
required.
d) Samples: Minimum 6 x 6 inch samples of specified panel; 8 inch long samples of exposed wall molding and
suspension system, including main runner and 4 foot cross tees.
e) Certifications: Manufacturer’s certifications that products comply with specified requirements, including
laboratory reports showing compliance with specified tests and standards.
f) Non-Conformance: All products not conforming to the requirements of this specification and or the
manufacturer’s published values are to be disposed. The Contractor performing the work will replace with
approved product at their expense.

1.6 SUSTAINABLE MATERIALS

a) Transparency: Manufacturers will be given preference when they provide documentation to support
sustainable requirements for the following: Material ingredient transparency, Removal of Red List Ingredients
per LBCV3, Life Cycle impact information, Low-Emitting Materials, and Clean Air performance.
1) Health Product Declaration. The end use product has a published, complete Health Product
Declaration with disclosure at a minimum of 1000ppm of known hazards in compliance with the
Health Product Declaration open Standard.
2) Declare Label. The end use product has a published Declare label by the International Living Future
Institute with disclosure of 100 ppm with a designation of Red List Free or Compliant (less than 1%
proprietary ingredients).
3) Low Emitting products with VOC emissions data. Preference will also be given to manufacturers that
can provide emissions data showing their products meet CDPH Standard Method v1.1 (Section 01350).
4) Life cycle analysis. Products that have communicated lifecycle data through Environmental Product
Declarations (EPDs) will be preferred.
5) End of Life Programs/Recycling: Where applicable, manufacturers that provide the option for recycling
of their products into new products at end-of-life through take-back programs will be preferred.
6) Products meeting LEED V4 requirements including:
a. Storage & Collection of Recyclables
4|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

b. Construction and Demolition Waste Management Planning


c. Building Life-Cycle Impact Reduction
d. Building Product Disclosure and Optimization Environmental Product Declarations
e. Building Product Disclosure and Optimization Sourcing of Raw Materials
f. Building Product Disclosure and Optimization Material Ingredients
g. Construction and Demolition Waste Management
1.7 QUALITY ASSURANCE
a) Single-Source Responsibility: Provide acoustical panel units and grid components by a single manufacturer.
b) Fire Performance Characteristics: Identify acoustical ceiling components with appropriate markings of
applicable testing and inspecting organization.
c) Surface Burning Characteristics: As follows, tested per ASTM E 84 and complying with ASTM E 1264
Classification.
d) Acoustical Panels: As with other architectural features located at the ceiling that may obstruct or skew the
planned fire sprinkler pattern through possibly delay or accelerate the activation of the sprinkler or fire
detection systems by channeling heat from a fire either toward or away from the device. Designers and
installers are advised to consult a fire protection engineer, NFPA 13, or their local codes for guidance where
automatic fire detection and suppression systems are present.
e) Coordination of Work: Coordinate acoustical ceiling work with installers of related work including, but not
limited to building insulation, gypsum board, light fixtures, mechanical systems, electrical systems, and
sprinklers. ACOUSTIBuilt Panels are 7/8” thick.
f) Installer Qualification: Subcontractor is an experienced Installer that has reviewed and understands the
system installation instructions thoroughly. Subcontractor will follow written installation instructions and
utilize approved equipment and procedures for finishing installation.
1.8 DELIVERY, STORAGE AND HANDLING
a) Deliver acoustical ceiling units to project site in original, unopened packages and store them in a fully enclosed
space where they will be protected against damage from moisture, direct sunlight, surface contamination, and
other causes.
b) Before installing acoustical ceiling units, permit them to reach room temperature and a stabilized moisture
content. Store all material within temperature limits required by manufacturer.
c) Handle acoustical ceiling units carefully to avoid chipping edges or damaged units in any way.
1.9 PROJECT CONDITIONS
a) Space Enclosure:
1) Building areas to receive ceilings shall be free of construction dust and debris. ACOUSTIBuilt panels should
be installed in areas where the building is enclosed and the HVAC is continuously functioning. This product
is not recommended for exterior applications, where standing water is present, or where moisture will
come into direct contact with the ceiling.
i. HVAC should be designed, installed, and operated in accordance with ASHRAE Standard 62.1.
It is also necessary for the area to be enclosed, for the HVAC systems to be functioning, and in
continuous operations for the life of the product. Product is not intended for use where
5|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

natural ventilation is part of the ventilation strategy and not recommended in areas where a
differential plenum pressure exists.

1.10 ALTERNATE CONSTRUCTION WASTE DISPOSAL


a) Reclaimed ceiling material must be kept dry and free from debris.
b) Contact the Armstrong Recycle Center a consultant will verify the condition of the material and that it meets
the Armstrong requirements for recycling. The Armstrong consultant with provide assistance to facilitate the
recycling of the ceiling.
c) Recycling may qualify for LEED Credits:
a. LEED 2009 - Category 4: Material and Resources (MR)
i. Credit MRc2: Construction Waste Management
d) LEEDv4 - MRp2 - Construction Waste Management Planning Qualifies as a material stream (non-structural)
targeted for diversion. Ceilings will be source-separated and diverted through the Armstrong Ceiling Recycling
Program.
a. LEEDv4-MRc5 -
i. Option 1: Divert ceilings to qualify for one of the 3 material streams (50%)
ii. Option 2: Divert ceilings to qualify for one of the 4 material streams (75%)

1.11 WARRANTY
a) Acoustical Panel: Submit a written warranty executed by the manufacturer, agreeing to repair or replace
panels that fail within the warranty period. Failures include, but are not limited to the following:
a. Acoustical Panels: Manufacturer’s defects in material
b. Grid System: Rusting and manufacturer's defects
b) Warranty Period:
a. Acoustical panels: Ten (10) years from date of substantial completion
b. Suspension: Ten (10) years from date of substantial completion
c) The Warranty shall not deprive the Owner of other rights the Owner may have under other provisions of the
Contract Documents and will be in addition to and run concurrent with other warranties made by the
Contractor under the requirements of the Contract Documents.

1.12 MAINTENANCE
a) Extra Materials: Deliver extra materials to Owner. Furnish extra materials described below that match
products installed. Packaged with protective covering for storage and identified with appropriate labels.
a. Acoustical Ceiling Units: Furnish quality of full-size units equal to 5.0 percent of amount installed.

6|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

b. Exposed Suspension System Components: Furnish quantity of each exposed suspension component
equal to 2.0 percent of amount installed.

I. PART 2 - PRODUCTS
2.1 MANUFACTURERS
a) Basis of Design ACOUSTIBuilt:
a. Armstrong World Industries, Inc.
b) Finish
a. Joint Compound Finish by Others
b. Spray Applied Finish by Armstrong World Industries, Inc.
c) Suspension Systems and Washers
a. Armstrong World Industries, Inc.
d) Perimeter Systems
a. Armstrong World Industries, Inc.

2.2.1 ACOUSTICAL CEILING UNITS


a) Acoustical Panels
1) Surface Texture: Fine
2) Composition: Mineral Fiber
3) Color: White (Fine Texture Finish for ACOUSTIBuilt panels)
4) Size: 48 in x 72 in x 7/8 in - Item #2604
5) Edge Profile: Tapered edges four sides
6) Noise Reduction Coefficient (NRC): ASTM C 423; Panel 0.80 (UL)
7) Ceiling Attenuation Class (CAC): ASTM C 1414; Panel 46 (UL), System up to 48
8) Sabin: Cloud Applications: 0.80 Sabins/SF & 1.33 Sabins/SF with infill item 8200T10
9) Articulation Class (AC): ASTM E 1111
10) Flame Spread: ASTM E 1264; Class A
11) Light Reflectance (LR) White Panel: ASTM E 1477; 0.87
12) Dimensional Stability: HumiGuard Plus
13) Recycle Content: Post-Consumer and Pre-Consumer – up to 75%
14) Material Ingredient Transparency: Health Product Declaration (HPD); Declare Label
15) Life Cycle Assessment: Third Party Certified Environment Product Declaration (EPD)

7|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

16) Acceptable Product: ACOUSTIBuilt panels #2604 No added formaldehyde as manufactured by


Armstrong World Industries
17) Contact your local Armstrong Representative for required installation training at least 4-6 weeks
before ordering materials and scheduling installation.
b) Finish
1. Joint Compound
a.Setting Compound: Lightweight setting-type drywall joint compound, Ultra lightweight drying-
type drywall joint compound
b.Joint Tape: Self-Adhesive mesh drywall joint tape
2. Spray Applied Finish – Required Product: #2605WH Fine Texture Finish for ACOUSTIBuilt panels –
White as manufactured by Armstrong World Industries.

For information regarding the ACOUSTIBuilt products, contact your Armstrong Sales Representative:
Name here, 123-345-4567, email [email protected]

c) Suspension Systems and Washers


1. Armstrong Drywall Suspension Systems all main beams and cross tees shall be commercial quality hot-
dipped galvanized steel
i. Main beam: manufactured main beam- 1-1/2" knurled face with ScrewStop™ reverse hem by
1-11/16 inches high. Drywall Main Beams are factory punched with cross tee routs, hanger
wire holes, and SuperLock™ main beam clip for a strong secure connection and fast accurate
alignment. Both ShortSpan and Drywall Main Beams are Heavy-duty performance per ASTM
C635
ii. HD8906 - 12ft HD Drywall Main Beam 1-1/2 in
2. Cross Tees: manufactured cross tee- 1-1/2" knurled face with ScrewStop™ reverse hem by 1-1/2
inches high with factory punched cross tee routs and hanger wire holes and XL stake on clip for a
strong secure connection.
i. XL8945P - 4ft Drywall Cross Tee
ii. XL8965 – 6ft Drywall Cross Tee
3. Wall Molding:
i. KAM12 - 12ft Knurled Angle Molding 1-1/4" Face
4. Hanger wire: a Class 1 zinc coating, soft temper, pre-stretched, with a yield stress load of at least time
three times the design load, but not less than 12-gauge.
5. Fasteners (for Panel attachment)
i. #6 x 1-5/8” Fine thread or sharp point self-drilling drywall screws
ii. Grip-Plate Washer for ACOUSTIBuilt panels (1-1/4”diameter) - #2119
6. Perimeter Systems

8|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

i. Commercial quality extruded aluminum alloy 6063 trim channel, factory finished in baked
polyester paint. Commercial quality galvanized steel unfinished T-bar connection clips;
galvanized steel splice plates.
1. Color: White
2. Size: 120 in X 4 in (also available in 6”)
3. Recycle Content: Post-Consumer - 50% Pre-Consumer - 0%
4. Acceptable Product: AXIOM One Piece for Drywall, 4in Straight – AX1PC4STR or
Curved AX1PC4CUR as manufactured by Armstrong World Industries
ii. Axiom Trim Channel:
1. AX4STR 4in Axiom Classic Straight
2. AX1PC4STR 4IN One –Piece Drywall Trim
iii. Axiom Bottom Trim with taping flange
1. AXBTASTR – Bottom Trim for ACOUSTIBuilt (also available in curved)
iv. Axiom Accessories:
1. AXSPLICE - Splice Plate
d) Material Ingredient Transparency: Health Product Declaration (HPD); Declare Label
e) Life Cycle Assessment: Third Party Certified Environmental Product Declaration (EPD)

II. PART 3 - EXECUTION


a) Prior to installation, contact your Armstrong Installation Systems Specialist (ISS). Before installation, inspect
previous work of all other trades. Verify that all work is complete and accurate to the point where this
installation may properly proceed in strict accordance with framing shop drawings.
b) If framing preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation
before proceeding.
c) The system installation is similar to a conventional drywall installation. However, there are key differences in
both material substrate and methods of finishing and installation that make this system unique. Installers
should review and follow all written directions of the installation instructions and view the installation video.
Click to follow to video access.
d) Installation: In accordance with all approved plans, details, and manufacturer's installation guidelines located
in the Armstrong ACOUSTIBuilt Assembly and Installation Instructions (BPLA-299099) Click to follow to
ACOUSTIBuilt Installation Instructions, and Drywall Grid Systems Hanging and Framing Flat Ceilings Installation
Guides (BPCS3539) Click to follow to Hanging and Framing Flat Drywall Instructions.
1. Install seismic components if required by the building code. Seismic components to be specified on
the architectural plans by the project engineer or design team.
2. Suspend main beam from overhead construction with hanger wires spaced 4-0 ft. or 6-0 ft. on center
along the length of the main runner. Install hanger wires plumb and straight.
3. Cross tees shall be installed 16” on center
4. Install wall moldings/perimeter trim at intersection of suspended ceiling and vertical surfaces

9|Page
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

5. Main runners and cross tees shall be attached at perimeter conditions


6. When determining the grid layout, consider the long edges of the boards must run parallel with the
cross tees.
7. This system relies on a square grid system to ensure panel edges align at centers of cross tees. If the
installation does not meet these squareness requirements, the panel edges may run off the grid
system.
i. The system must be square to within 1/8" over a 48" x 48" module.
ii. The suspension system must be leveled to within 1/4" in 10'.
8. Floating perimeters must be trimmed with either Axiom® One-Piece Drywall Trim or Axiom® Classic
with Bottom Trim for ACOUSTIBuilt™. Refer to the installation instructions for integration with
ACOUSTIBuilt installations.

3.2.1 PREPARATION
a) Do not proceed with installation until all wet work such as concrete, terrazzo, plastering and painting has
been completed and thoroughly dried out, unless expressly permitted by manufacturer's printed
recommendations.
b) Coordination: Furnish layouts for preset inserts, clips, and other ceiling anchors whose installation is
specified in other sections.
c) Furnish concrete inserts and similar devices to other trades for installation well in advance of time needed
for coordination of other work.

3.2.3 INSTALLATION
a) Follow manufacturer installation instructions. Armstrong ACOUSTIBuilt Assembly and Installation Instructions
(BPLA-299099) Click to follow to ACOUSTIBuilt Installation Instructions
b) Controls joints are required following the standards used for gypsum board listed in ASTM C840, Section 20
I. Ceilings with perimeter relief cannot exceed 50 LF and 2500 SF between control joints
II. Ceilings without perimeter relief cannot exceed 30 LF and 900 SF between control joints
c) Panel joints and fasteners are finished with tape and compound to create a flat surface. While the materials
used to finish ACOUSTIBuilt panels are also used to finish drywall, the procedure has unique requirements.
d) Joint compound coverage shall be limited to preserve the acoustical performance of the panels. Compound at
panel joints shall not exceed 8 inch widths. Compound applied to field fasteners shall not exceed 4 inch by 4-inch
areas. All compound shall be smooth and free of tool marks and ridges. Panels are to be finished with taping
knives. Production tools, including boxes, are not permitted.
e) Sanding and inspection: Throughout the sanding process, inspect the surface frequently for flatness. Direct a
light across the ceiling to highlight unevenness that requires attention.
f) Fine Texture Finish shall be applied in 4 coat process (additional coat may be used to achieve the desired finish)
as called out in the installation instructions. Fine Texture Finish for ACOUSTIBuilt is applied in multiple coats,
10 | P a g e
Firm Name: Address:
Telephone: E-mail address
Ceiling Specification Sheet

layered to achieve a uniform appearance and acoustical performance. It is strongly encouraged to practice
spraying to ensure proper calibration and technique are achieved. Refer to the installation video.
I. Must be applied with an air assist spray system (refer to manufacturers installation instructions for
required equipment). The Fine texture finish is not intended for use with airless spay or to be manually
applied by rolling.
II. See Manufactures installation instructions for correct pressure settings for spray system, finish
preparation, spray calibration and spray procedure and technique.

3.2.4 ADJUSTING AND CLEANING


a) To remove soot, dirt, and dust use a vacuum operating at low power with a soft brush or use a dry soot
cleaning sponge.
b) Clean exposed surfaces of acoustical ceilings, including trim, edge moldings, and suspension members. Comply
with manufacturer's instructions for cleaning and touch up of minor finish damage. Remove any ceiling
products that cannot be successfully cleaned and or repaired. Replace with attic stock or new product to
eliminate evidence of damage.
c) Before disposing of ceilings, contact the Armstrong Recycling Center at 877-276-7876, select option #1 then #8
to review with a consultant the condition and location of building where the ceilings will be removed. The
consultant will verify the condition of the material and that it meets the Armstrong requirements for recycling.
The Armstrong consultant with provide assistance to facilitate the recycle of the ceiling.

End of Section

ACOUSTIBuilt™ FINISH SCHEDULE

ACT-1 Armstrong ACOUSTIBuilt™ Seamless Acoustical Ceiling System – Panel #2604 (48”x72”x7/8”), UL
Classified NRC of 0.80 and tapered edges on all 4 sides. Panels are to be installed on Armstrong 1-1/2”
Drywall grid system with Main Runner #HD8906 installed 4’0” OC, 4’Tee #XL8945P installed 16” OC and KAM
wall angle #KAM1512. Finish joint seams and Grip Plate Washer #2119 locations to a level 4 finish with
required joint compound. Color is to be white or any custom color with a LRV greater than 50%. Spray with
4 coats of Fine Texture Finish #2605WH. The installed wall to wall system performance is to be NRC up to
0.80, CAC 48, Cloud installations are 0.80 Sabins/SF or 1.33 Sabins/SF with infill item 8200T10, LR .87, Class
A, BioBlock and HumiGuard Plus Sag Performance. Install all steps per the manufacturer’s installation
instructions. Contact local Armstrong rep name here at xxx-xxx-xxxx for required installation training at least
4-6 weeks before ordering materials and scheduling installation. 11 | P a g e
Firm Name: Address:
Telephone: E-mail address

You might also like