0% found this document useful (0 votes)
61 views2 pages

4 Speed Quiet Ceiling Fan/Light Control - Single Pole (One Location)

This document provides instructions for installing a 4-speed ceiling fan light control. It can be used to control a single ceiling fan and light, or multiple fans of the same type. The control allows for full range dimming of incandescent lamps up to 300W. Tools needed for installation include screwdrivers, pliers, wire strippers, and a ruler. Warnings are provided regarding proper wiring and not exceeding the 1.5A maximum load rating. Steps are outlined for preparing the wires, connecting them to the control according to color coding, mounting the control box to the junction box, and restoring power.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views2 pages

4 Speed Quiet Ceiling Fan/Light Control - Single Pole (One Location)

This document provides instructions for installing a 4-speed ceiling fan light control. It can be used to control a single ceiling fan and light, or multiple fans of the same type. The control allows for full range dimming of incandescent lamps up to 300W. Tools needed for installation include screwdrivers, pliers, wire strippers, and a ruler. Warnings are provided regarding proper wiring and not exceeding the 1.5A maximum load rating. Steps are outlined for preparing the wires, connecting them to the control according to color coding, mounting the control box to the junction box, and restoring power.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

4 Speed Quiet Ceiling Fan/Light Control – Single Pole (One location)

Cat. No. RTDØ1-1Ø,


Fan Control
Rated: 1.5A-120VAC, 60Hz
DI-000-RTD01-02B Full Range Dimming Incandescent Lamp Load
Rated: 300W-120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS: WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes • To reduce the risk of fire or electrical shock, this control is to be used with
and regulations. ceiling fans that are marked as suitable for use with solid-state fan speed control
• If you are unsure about any part of these instructions, consult a qualified and is rated 120VAC, total load 1.5 amperes maximum.
electrician. • For use on ceiling paddle fans with split-capacitor or shaded pole motors only.
• To avoid overheating and possible damage to this device and other equipment, Please refer to manufacture's instructions or rating label on the motor to
do not install to control a receptacle, fluorescent lighting, a motor- or a confirm type. Use with any other types of motors or equipment may cause
transformer-operated appliance other than appropriate ceiling fans and overheating and/or damage to the motors or equipment.
incandescent lamps. • Disconnect power at circuit breaker or fuse when servicing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use
only devices marked CO/ALR or CU/AL.

Tools needed to install your Fan Speed MULTI-DEVICE APPLICATION Step 2 Preparing wires:
Control: NOTE: There is NO derating necessary for multi-gang
installations of this Fan Speed Control. • Pull off pre-cut insulation from Control leads.
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil • Make sure that the ends of the wires from the
Cutters Ruler wall box are straight (cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each
Color Change Option: wire in the wall box (shown).
If a color change kit is provided with your device,
proceed with the following step if you need to change
the color. Otherwise, proceed with the "Installing Strip 5/8"
Fan Speed/Light Control by itself or with other (1.6 cm)
devices" section.
MULTI-FAN CONTROL Cut 5/8"
Changing the color of your Fan Speed/ (1.6 cm)
Any number of fans of the same type may be (if necessary)
Light Control
controlled by a single fan speed control provided that
Your Fan Speed Control includes two color options. The the total amperage of the fans do not exceed the Strip Gage
Control ships with the White frame attached. To change amperage of the fan speed control.
color of frame, proceed as follows:
INSTALLING YOUR FAN SPEED/LIGHT
CONTROL
NOTE: Use check boxes √ when Steps are Step 3 Single-Pole Wiring Application:
completed.
ED LO MED LO
IM HI
AX
XH

Step 1 WARNING: To avoid fire, shock, or


M
A
OFF M

OFF

death; TURN OFF POWER at circuit Black


breaker or fuse and test that power is off Neutral
before wiring!
Push in side at tab Press on knob. Line up Green
to release. Remove tabs on back of frame and
frame and knob. press in side to attach Ground
OFF ON OFF ON
Yellow
OFF ON OFF ON

Installing Fan Speed/Light Control by OFF ON OFF ON Red

itself or with other devices: OFF


OFF
ON
ON
OFF
OFF
ON
ON

If installing Control in a single device application, OFF ON OFF ON

proceed with the MULTI-FAN CONTROL section. If


installing Control in a multi-device application,
proceed as follows:
Insert wires
straight then twist Electrical
clockwise Tape
Step 3a Single-Pole Wiring Application: Step 4a • Restore power at circuit breaker or Step 7 OPERATION
con’t con’t fuse.
Fan Speed/Dimmer • Carefully holding control as
shown, proceed as follows: Dimmer:
Red (Motor) Hot
Yellow (Light) Hot Dimmer: Rotate top knob control ON
Hot (Black) AX
HI M

clockwise and counter-clockwise.


E
M

D
OFF
Black Black

LO
Black Rotate top control knob
Lights should turn DIM and BRIGHTEN clockwise – Lights will turn
Line Light Fan HI M
120VAC, 60Hz Green accordingly. ON at level set by knob. M
AX E

D
OFF
Ground
If light does not turn ON, refer to the

LO
White White
TROUBLESHOOTING section. OFF
Neutral (White) Rotate top control knob fully
Fan Speed: Rotate bottom knob to the
counter-clockwise – Lights
MAX position. Fan should turn ON to
Connect wires per WIRING DIAGRAM as will turn OFF.
highest level. Rotate knob to the
follows: Screw wire nuts on clockwise making remaining levels: HI, MED, and LO. BRIGHTEN
sure no bare conductors show below the wire Fan speed should change accordingly. Rotate top control knob
connectors. Secure each connector with If fan does not turn ON, refer to the clockwise to desired brightness level.
electrical tape. TROUBLESHOOTING section. DIM
• Green control Ground lead to Green or bare Rotate top control knob counter-clockwise to desired
copper wire in wall box. dim level.
• Black control lead to Line (Hot) wall box wire Step 5 Fan Speed/Light Control Fan Speed:
removed from old switch. Mounting:
ON
• Red control lead (motor Hot) to Black Fan wall TURN OFF POWER AT CIRCUIT Rotate bottom control knob to each of the four levels:
box wire. MAX, HI, MED, and LO – Fan will increase or
• Yellow control lead (Light Hot) to Black Light decrease in speed respectively for desired level.
Installation may now be
wall box wire. completed by carefully OFF
• Proceed to Step 6. positioning Rotate bottom control knob counter-clockwise to the
all wires to provide room OFF position – Fan will turn OFF.
M
AX
HI M
E
in wall box for control.
D

Mount control
OFF

LO

Step 4 Testing your Fan Speed/Light into box with mounting TROUBLESHOOTING
Control prior to mounting in wall screws supplied. Attach
box: wallplate. • Fan does not turn ON or does not run Multispeed
- Circuit breaker or fuse has tripped.
- Fan is not connected to line Neutral.
- Switch on Fan not set to HIGH position.
- Fan and light miswired.
BREAKER OR FUSE.
Step 6 • Light does not turn ON
Restore Power: Restore power at - Circuit breaker or fuse has tripped.
circuit breaker or fuse. Installation is - Bulb has burned out.
complete.
- Lamp is not connected to line Neutral.
- Switch on Fan unit controlling Light is not in
the ON position (if applicable).
- Fan and light miswired.
HI MED L
AX O
M
OFF

For non-standard wiring applications, refer


to Wire Nut and Conductor Size Chart
PRODUCT INFORMATION WIRE NUT / # OF CONDUCTOR
COMBINATION CHART
• For technical assistance, contact us at
1- #12 w/ 1 to 3 #14, #16 or #18
1-800-824-3005.
2- #12 w/ 1 or 2 #16 or #18
• Visit our website at www.leviton.com. 1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS


Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal
and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned
prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York
11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper
environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or
implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied
warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation,
damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty,
whether based on contract, tort or otherwise. DI-000-RTD01-02B

You might also like