DESIGN CONSIDERATIONS FOR MOUNTED
STORE ROOM (GRASS GODOWN) AT CHHANI-
VADODARA
1.0 LOAD CALCULATIONS
GENERAL DATA
1. Length of building dx = 12.5m
2. Width of building dz = 8m
3. Height of building h = 6m
4. Seismic zone = III
5. Zone factor = 0.16
6. Importance factor = 1.5
7. No Future expansion considered
8. Grade of concrete = M25(for foundation and plinth beams)
9. Grade of concrete = M20(for roof beams)
10. Grade of steel = Fe500
Load calculations
Wall load transfer on beams as udl (kN/m)
230mm thk. masonry wall
Height of wall = 6m
Density of masonry wall = 25 kN/m² (Including plaster)
Weight of wall per m run, w = (6-0.525) x 0.26 x 25 = 35.6 kN/m
100mm thk. masonry wall
Height of wall = 1m
Density of block wall = 25 kN/m² (Including plaster)
Weight of wall per m run, w = 1 x 0.26 x 25 = 6.5 kN/m
Point load on masonry at roof,
Dead load of purlin (122x61x3.6) = weight per m x length
= 0.0967 x 6.15
= 0.6 KN/m
Dead load of sheet = weight per m x length
= 0.225 x 6.15
= 1.384 KN/m
Total load = 0.6 + 1.384
= 2 KN (at mid)
= 1 KN (at end)
Live Load (As per IS 875(Part-2)-1987
Point Load (sheet) = 0.75x6.15 = 4.65 KN (AT MID)
= 2.5 KN (AT END)
1000mm wide cantilever projection load and moment transfer on beam as udl
Total dead load of projection = 6.5 kN/m2
Live load on projection = 1.5 kN/m2
Span of cantilever slab lx = 1.0 m
DL as udl on beam = 6.5 x 1.0 = 6.5 kN/m
DL as moment on beam = 6.5 x 1.02/2 = 3.25 kN.m/m
LL as udl on beam = 0.75 x 1.0 = 0.75 KN/m
LL as moment on beam = 0.75 x 1.02/2 = 0.375 kN.m/m
600mm wide cantilever projection load and moment transfer on beam as udl
Total dead load of projection = 6.5 kN/m2
Live load on projection = 0.75 kN/m2
Span of cantilever slab lx = 0.6 m
DL as udl on beam = 6.5 x 0.6 = 3.9 kN/m
DL as moment on beam = 6.5 x 0.62/2 = 1.17 kN.m/m
LL as udl on beam = 0.75 x 0.6 = 0.45 KN/m