Masterseal 550: Description Advantages

MasterSeal 550 is a two-component acrylic cementitious coating that provides a flexible waterproof barrier. It bonds to most surfaces and protects against water, salts, and gases. It can be applied to concrete after 24 hours to immediately protect surfaces.

Uploaded by

maria
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views3 pages

Masterseal 550: Description Advantages

MasterSeal 550 is a two-component acrylic cementitious coating that provides a flexible waterproof barrier. It bonds to most surfaces and protects against water, salts, and gases. It can be applied to concrete after 24 hours to immediately protect surfaces.

Uploaded by

maria
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

MasterSeal® 550

Acrylic reinforced cementitious, flexible waterproof coating

DESCRIPTION ADVANTAGES
MasterSeal 550 is a two component acrylic • Waterproof
modified cementitious coating that requires only on • Excellent adhesion. Bonds to porous and non-
site mixing to form the ideal product to waterproof porous surfaces.
and resurface concrete, masonry, and most other • Flexible.
construction materials. • Non toxic suitable for contact with potable
Simply applied by stiff brush, roller, or trowel, it water.
forms a waterproof, flexible coating. • Suitable for light pedestrian traffic.
MasterSeal 550 provides an effective barrier to • Breathable - whilst repelling water, allows
waterborne salts and atmospheric gases. substrate to breathe.
Fluid applied, MasterSeal 550 provides a hard • High resistance to chloride ion diffusion.
wearing, seamless, waterproof membrane for • Unlike conventional coatings which require a
roofs and foundation protection. 7-28 day cure of concrete, MasterSeal 550 can
be applied to 24 hour-old concrete thereby
TYPICAL APPLICATIONS giving immediate protection.
• To reface and even out variations in concrete
surfaces. COMPOSITION
• As a waterproof lining for water retaining MasterSeal 550 is composed of specially selected
structures. cements, silica sand and reactive fillers supplied in
• For coating seawater channels. powder form together with a liquid component of
• Sealing and coating tie bar holes to ensure blended acrylic copolymers and wetting agents.
watertightness.
• For waterproofing and protection against TYPICAL PROPERTIES*
brackish water.
• To provide foundation protection.
Density: 1826kg/m³
• As a waterproof coating for roofs. Toxicity: Non toxic - Suitable for
• As a backing to marble and granite to prevent use in contact with
water ingress and thus alleviate surface potable water
staining. Initial surface absorption: >95% reduction against
• To provide protection to concrete surfaces from control
carbonation and chloride attack. Chloride ion diffusivity: Not measurable after
• For use on pedestrian walkways in marine 24 months of testing
Moisture vapour SD < 1.5m (839µm dft)
areas.
transmission (equivalent
air layer thickness):
PACKAGING
MasterSeal 550 is available in 20kg double pack. STANDARDS
WRAS - "Suitable for use in contact with potable
MasterSeal 550 is available in three standard water" - BS 6920 : 2000.
colours: J-Light Grey, K-White and H-Dark Grey.
MasterSeal® 550

CHLORIDE ION DIFFUSIVITY MIXING


MasterSeal 550 provides an effective barrier to MasterSeal 550 is supplied in premeasured units
waterborne salts such as chlorides and sulphates. and should be mixed on site utilising clean
*lndependent assessment has shown that even containers. Slowly add the powder to the liquid
after 12 months constant immersion the chloride and mix, using a slow speed drill fitted with a
ion diffusion co-efficient could not be measured for suitable paddle. MIX AND USE. Do not mix more
MasterSeal 550. material than can be used in one hour.
NOTE: Although MasterSeal 550 is supplied in
CHEMICAL RESISTANCE premeasured packs, part packs can be used by
MasterSeal 550 has outstanding wear and mixing 2 volumes of powder to 1 volume of liquid.
Mix thoroughly and keep mixed during application.
weather resistance and good resistance to sodium
DO NOT RE-TEMPER WITH WATER.
hydroxide, calcium chloride, de-icing salts.
MasterSeal 550 coated surfaces exhibit good
resistance to mild acids. APPLICATION
Do not apply to dry concrete
ANTI CARBONATION COATING Saturate concrete surfaces with clean water whilst
still visibly damp, but free of standing water, apply,
MasterSeal 550 is an extremely effective barrier to
using a short, stiff bristle brush or roller. Trowel
atmospheric acidic gases which cause carbonation
application can be undertaken as necessary. For
in concrete structures.
heavy 6-10mm depressions, honeycombs etc. use
MasterSeal 550 at an applied rate of 1.8 kg/m²
less gauging liquid and mix to the desired
gives an equivalent air layer thickness for carbon
consistency. Where more than one coat is found
dioxide diffusion (R) of 92 metres. The accepted
necessary to achieve the desired thickness, apply
minimum value for R is 50m. Testing to confirm
the second or subsequent coats after the previous
this was carried out independently by Taywood
coat has dried.
Engineering 2005. A report is available on
request.
It is recommended, for general resurfacing, that
each coat should be a minimum of 1mm thick.
APPLICATION PROCEDURE Spray application is recommended for large areas,
Surface preparation: details of suitable equipment can be provided by
As with all coating systems, surface preparation is BASF’s Technical Service Dept.
of prime importance. Remove all grease, oil, dust,
residual curing compound, mould release agent or COVERAGE
other contaminant that could impair adhesion. 1.826 kg / m² at 1 mm thickness.
Laitance should preferably be removed by light
sweep blasting or hydro-jetting. Mechanical wire
brushing may be appropriate for small areas.
Spalled concrete should be cut back to sound
concrete and made good with a suitable
cementitious repair mortar such as
MasterEmaco S 488. Conventional concrete
curing compounds should be removed before
application. The exception to this is when
MasterKure 181 has been used. Roofing tiles
should be firmly bedded and grouted before
application.
MasterSeal® 550

SPECIFICATION CLAUSE STORAGE


Store out of direct sunlight, clear of the ground on
All exposed concrete surfaces Not measurable pallets protected from rainfall. Avoid excessive
are to be coated with after 24 months compaction.
MasterSeal 550, a two of testing
component reactive polymer Failure to comply with the recommended storage
composite. The material shall conditions may result in premature deterioration of
be mixed and applied fully in the product or packaging. For specific storage
accordance with the
manufacturer's instructions.
advice consult BASF's Technical Services
The cured coating shall have Department.
the following diffusion
properties. Chloride ion NOTE
diffusion
Field service, where provided, does not constitute
Moisture vapour transmission SD < 1.5m
(equivalent air layer thickness) (800µm dft)
supervisory responsibility. For additional
information contact your local BASF
representative.
NOTES
Where subsequent tiling works are to be carried BASF reserves the right to have the true cause of
out on vertical surfaces, contact the local BASF any difficulty determined by accepted test
representative for advice. methods.

SAFETY PRECAUTIONS QUALITY AND CARE


As with all chemical products, care should be All products originating from BASF’s Dubai, UAE
taken during use and storage to avoid contact with facility are manufactured under a management
eyes, mouth, skin and foodstuffs. Treat splashes system independently certified to conform to the
to eyes and skin immediately. If accidentally requirements of the quality, environmental and
ingested, seek immediate medical attention. occupational health & safety standards ISO 9001,
ISO 14001 and OHSAS 18001.

* Properties listed are based on laboratory controlled tests.

® = Registered trademark of the BASF-Group in many countries.

BASF_CC-UAE/Sl_550_12_94/v5/11_16
The technical information and application advice given in this BASF publication are based on the present state of
STATEMENT OF our best scientific and practical knowledge. As the information herein is of a general nature, no assumption can be
RESPONSIBILITY made as to a product's suitability for a particular use or application and no warranty as to its accuracy, reliability or
completeness either expressed or implied is given other than those required by law. The user is responsible for
checking the suitability of products for their intended use.

Field service where provided does not constitute supervisory responsibility. Suggestions made by BASF either
NOTE orally or in writing may be followed, modified or rejected by the owner, engineer or contractor since they, and not
BASF, are responsible for carrying out procedures appropriate to a specific application.

BASF Construction Chemicals UAE LLC


Disclaimer: the LRQA mark relates
P.O. Box 37127, Dubai, UAE to certified management system and
Tel: +971 4 8090800, Fax: +971 4 8851002 not to the product mentioned on this
www.master-builders-solutions.basf.ae datasheet

You might also like