Automated Reid Vapor Pressure Analyzer Autoreid: Standards Astm D323 Astm D4953 Iso 3007 Ip 69
The AutoREID from AD Systems is an automated vapor pressure analyzer that complies with industry standards. It directly measures Reid vapor pressure and calculates true vapor pressure. Key features include two independent measurement positions, automated operation, full traceability of results, and a user-friendly interface. It provides a modern alternative for precise vapor pressure testing of fuels and other petroleum products.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
127 views2 pages
Automated Reid Vapor Pressure Analyzer Autoreid: Standards Astm D323 Astm D4953 Iso 3007 Ip 69
The AutoREID from AD Systems is an automated vapor pressure analyzer that complies with industry standards. It directly measures Reid vapor pressure and calculates true vapor pressure. Key features include two independent measurement positions, automated operation, full traceability of results, and a user-friendly interface. It provides a modern alternative for precise vapor pressure testing of fuels and other petroleum products.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Automated REID vapor pressure analyzer
AutoREID
Direct REID Vapor Pressure (RVP) measurement
True Vapor Pressure (TVP) calculation Highest level of test automation Two independent measurements positions Perfectly suited for testing viscous and difficult products Full traceability, complete result documenting Small foot print, fast warm up, precise measurements Modern user-friendly interface The AutoREID apparatus from AD Systems is a modern automated Reid Vapor pressure Standards instrument in full compliance with ASTM D323-B and similar standards. This specification ASTM D323 test method covers procedure for the determination of vapor pressure of gasoline, ASTM D4953 volatile crude oil, and other volatile petroleum products. The Reid method is particularly ISO 3007 suitable for determination of vapor pressure of crude oil for transportation, storage and IP 69 general handling purpose. The instrument directly measures the Reid vapor pressure without correlation or calculation. Modern ergonomic design, high level of test automation, convenience in operation makes the AutoREID considerable alternative to mini-methods for precise vapor pressure measurement. Compact instrument with two measurement positions allows performing two simultaneous measurements independently. Special additional position in the bath is dedicated for air chamber conditioning increasing the test productivity. The test pressure vessels with fast coupling assure fast and easy operation. The AutoREID design allows testing viscous sticky samples or samples containing mechanical sediments without a risk of the instrument damage.All parts of test pressure vessel are easy to disassemble and clean. Vigorous mechanical agitation of pressure vessels accelerates pressure stabilization even on “difficult” samples like crude oil. Operation Test documenting The sample prepared in accordance with test method All details related to each test result are memorized. requirements is filled in liquid chamber which is coupled Complete test report including sample ID, operator name, in a second with air chamber by means of specially date/time, RVP value, pressure curve is displayed on the designed quick coupling connector. The assembled screen and saved into built-in database. It can be printed, pressure vessel is completely sealed. The operator enters transferred on a USB memory stick and/or send to a LIMS test identification information by a few keystrokes, place when the AutoREID is connected to a LAN. the pressure vessel in water bath precisely maintained at Multi-criteria search function facilitates retrieval of test 37,8°C (100°F) and connect the pressure link by fast report in the database. The software is able to calculate connector. Plug and go operation. The test starts and report average RVP value of two parallel automatically. The pressure vessel is agitated by reverse measurements of the same sample. rotation and pressure curve is displayed in real time on Ordering information the large graphic screen. AA310‐001 AutoREID –Automated Reid vapor pressure instrument Supplied without REID pressure vessels to be ordered separately AK310-006 AutoREID Pressure Calibration Kit Technical specification Test method ASTM D 323, D4953, ISO 3007 Reported results REID or TVP Bath 37.8°C (100°F) or 50.0°C Pressure range Up to 250 kPa Resolution 0,1 kPa Test time Less than 15 minutes typical Interface 8’ full-color touch screen Language English, French, Russian As soon as maximum stable pressure is reached the test Results storage Database, USB stick, LAN stops automatically and saturated vapor pressure (RVP) is Communication 2 х USB 2.0, Ethernet port recorded. Printing Graphic printer (optional) Two simultaneous measurements can be run Stainless steel bath with capacity of Bath independently and simultaneously. 31 Liters Quality and Safety Dimensions 720 x 440 x 460 mm During the test progress the software monitors for leaks Weight 30 kg and prevent the operator in case of pressure drop. To 230V; 50 or 60Hz Power supply assure high quality of results and safety of operation the Consumption: 2kW We reserve the right to alter specifications without notification watchdog system permanently monitors the bath temperature stability, bath liquid level, overpressure or For additional information: overheating. AD Systems Transparent bath cover helps to the operator visual P.A. Portes de la Suisse Normande inspection of the pressure vessels under the test. Allée de Cindais Instrument calibration is easy to perform on-site via 14320 Saint André sur Orne - France dedicated menu. Pressure transducers can be checked +33 (0)2 31 75 02 68 against a reference manometer at any time. The special T- Email: [email protected] connector for each measurement position is built-in for this www.adsystems-sa.com purpose. The bath temperature can be checked by the reference thermometer. The bath cover has special opening for this purpose. All information related to the instrument calibration is memorized to ensure a perfect traceability. The instrument calibrations are date/time tagged. The calibration interval can be managed in the software.