0% found this document useful (0 votes)
41 views

Table - Selection

The document provides specifications for schedule 40 and schedule 80 steel pipe including nominal pipe size, outer diameter, wall thickness, weight of empty and water-filled pipe, maximum recommended span between hangers, and recommended hanger rod sizes. It notes that local codes may require closer hanger spacing if additional fittings are present. Water weighs 62.41 pounds per cubic foot and the specifications are based on standards from ASTM and MSS SP-69.

Uploaded by

Soumya Sameer
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views

Table - Selection

The document provides specifications for schedule 40 and schedule 80 steel pipe including nominal pipe size, outer diameter, wall thickness, weight of empty and water-filled pipe, maximum recommended span between hangers, and recommended hanger rod sizes. It notes that local codes may require closer hanger spacing if additional fittings are present. Water weighs 62.41 pounds per cubic foot and the specifications are based on standards from ASTM and MSS SP-69.

Uploaded by

Soumya Sameer
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Reference Data Schedule 40 Steel Pipe Data

Nominal Wall Weight of Pipe Maximum Recommend


Pipe Size Pipe O.D. Thickness Weight of Pipe Filled With Water Span* edHanger
In. (mm) In. (mm) In. (mm) Lbs./Ft. (kg/m) Lbs./Ft. (kg/m) Ft. (Meter) RodSizes
3/8" (10) .675 (17.1) .091 (2.3) .6 (0.9) .7 (1.0) 7 (2.13) 3/8"-16

1/2" (15) .840 (21.3) .109 (2.7) .8 (1.2) .9 (1.2) 7 (2.13) 3/8"-16

3/4" (20) 1.050 (26.7) .113 (2.9) 1.1 (1.7) 1.3 (2.0) 7 (2.13) 3/8"-16

1" (25) 1.315 (33.4) .133 (3.4) 1.7 (2.5) 2.1 (3.0) 7 (2.13) 3/8"-16

11/4" (32) 1.660 (42.1) .140 (3.5) 2.3 (3.4) 2.9 (4.3) 7 (2.13) 3/8"-16

11/2" (40) 1.900 (48.2) .145 (3.7) 2.7 (4.0) 3.6 (5.3) 9 (2.74) 3/8"-16

2" (50) 2.375 (60.3) .154 (3.9) 3.6 (5.4) 5.0 (7.5) 10 (3.05) 3/8"-16

21/2" (65) 2.875 (73.0) .203 (5.1) 5.8 (8.6) 7.9 (11.7) 11 (3.35) 1/2"-13

3" (80) 3.500 (88.9) .216 (5.5) 7.6 (11.2) 10.8 (15.9) 12 (3.66) 1/2"-13

31/2" (90) 4.000 (101.6) .226 (5.7) 9.1 (13.5) 13.4 (19.8) 13 (3.96) 1/2"-13

4" (100) 4.500 (114.3) .237 (6.0) 10.8 (16.0) 16.3 (24.2) 14 (4.27) 5/8"-11

5" (125) 5.563 (141.3) .258 (6.5) 14.6 (21.7) 23.2 (34.6) 16 (4.87) 5/8"-11

6" (150) 6.625 (168.3) .280 (7.1) 19.0 (28.2) 31.5 (46.8) 17 (5.18) 3/4"-10

8" (200) 8.625 (219.1) .322 (8.2) 28.5 (42.5) 50.1 (74.6) 19 (5.79) 3/4"-10
R eference D ata

10" (250) 10.750 (273.0) .365 (9.3) 40.5 (60.2) 74.6 (110.9) 22 (6.69) 7/8"-9

12" (300) 12.750 (323.8) .406 (10.3) 51.1 (75.9) 102.1 (151.9) 23 (7.01) 7/8"-9

14" (350) 14.000 (355.6) .437 (11.1) 63.0 (93.7) 121.5 (180.7) 25 (7.62) 1"-8
16" (400) 16.000 (406.4) .500 (12.7) 83.0 (123.5) 159.5 (237.3) 27 (8.23) 1"-8
18" (450) 18.000 (457.2) .563 (14.3) 105.0 (156.2) 202.2 (300.8) 28 (8.53) 1"-8
20" (500) 20.000 (508.0) .593 (15.1) 123.0 (183.0) 243.4 (361.8) 30 (9.14) 11/4"-7
24" (600) 24.000 (609.6) .687 (17.4) 171.0 (254.5) 345.2 (513.7) 32 (9.75) 11/4"-7

Bas on ASTM A53-86.


1cubic
ed ft. of water weighs 62.41 lbs.
1gallon (U.S.) weighs 8.335 lbs.
1cubic meter of water weighs 999.97 kg.
1literweighs .999 kg.

Bas on MSS SP-69 Table 3 & 4.


*Man
ed codes require pipe hangers to be spaced every 10' (3.048 meters)
regardles
y of size. Check local codes.
Spacin
s and capacities are based on water filled pipe. Closer hanger spacing
m
g be required where additional valves and fittings increase the load.
ay

Ea B-Line series Pipe Hangers & S


305
ton u
p
Schedule 80 Steel Pipe Data
Nominal Wall Weight of Pipe Maximum Recommend
Pipe Size Pipe O.D. Thickness Weight of Pipe Filled With Water Span* edHanger
In. (mm) In. (mm) In. (mm) Lbs./Ft. (kg/m) Lbs./Ft. (kg/m) Ft. (Meter) RodSizes
3/8" (10) .675 (17.1) .126 (3.2) .7 (1.1) .8 (1.2) 7 (2.13) 3/8"-16

1/2" (15) .840 (21.3) .147 (3.7) 1.1 (1.6) 1.2 (1.7) 7 (2.13) 3/8"-16

3/4" (20) 1.050 (26.7) .154 (3.9) 1.5 (2.2) 1.7 (2.5) 7 (2.13) 3/8"-16

1" (25) 1.315 (33.4) .179 (4.5) 2.2 (3.2) 2.5 (3.6) 7 (2.13) 3/8"-16

11/4" (32) 1.660 (42.1) .191 (4.8) 3.0 (4.4) 3.5 (5.2) 7 (2.13) 3/8"-16

11/2" (40) 1.900 (48.2) .200 (5.1) 3.6 (5.4) 4.3 (6.5) 9 (2.74) 3/8"-16

2" (50) 2.375 (60.3) .218 (5.5) 5.0 (7.5) 6.3 (9.4) 10 (3.05) 3/8"-16

21/2" (65) 2.875 (73.0) .276 (7.0) 7.6 (11.4) 9.4 (14.1) 11 (3.35) 1/2"-13

3" (80) 3.500 (88.9) .300 (7.6) 10.2 (15.2) 13.0 (19.4) 12 (3.66) 1/2"-13

31/2" (90) 4.000 (101.6) .318 (8.1) 12.5 (18.6) 16.3 (24.3) 13 (3.96) 1/2"-13

4" (100) 4.500 (114.3) .337 (8.5) 15.0 (22.3) 20.0 (29.7) 14 (4.27) 5/8"-11

5" (125) 5.563 (141.3) .375 (9.5) 20.8 (30.9) 28.7 (42.6) 16 (4.87) 5/8"-11

6" (150) 6.625 (168.3) .432 (11.0) 28.6 (42.5) 39.9 (59.3) 17 (5.18) 3/4"-10

8" (200) 8.625 (219.1) .500 (12.7) 43.4 (64.5) 63.1 (93.9) 19 (5.79) 3/4"-10

R eference D ata
10" (250) 10.750 (273.0) .593 (15.0) 64.4 (95.8) 95.5 (142.1) 22 (6.69) 7/8"-9

12" (300) 12.750 (323.8) .687 (17.4) 88.6 (131.8) 132.6 (197.3) 23 (7.01) 7/8"-9

14" (350) 14.000 (355.6) .750 (19.0) 107.0 (159.2) 158.2 (235.4) 25 (7.62) 1"-8
16" (400) 16.000 (406.4) .843 (21.4) 137.0 (203.9) 206.7 (306.6) 27 (8.23) 1"-8
18" (450) 18.000 (457.2) .937 (23.8) 171.0 (254.5) 259.5 (386.2) 28 (8.53) 1"-8
20" (500) 20.000 (508.0) 1.031 (26.2) 209.0 (311.0) 318.4 (473.8) 30 (9.14) 11/4"-7
24" (600) 24.000 (609.6) 1.218 (30.9) 297.0 (442.0) 455.2 (677.4) 32 (9.75) 11/4"-7

Based on ASTM A53-86.


1 cubic ft. of water weighs 62.41 lbs.
1 gallon (U.S.) weighs 8.335 lbs.
1 cubic meter of water weighs 999.97 kg.
1 liter weighs .999 kg.

Based on MSS SP-69 Table 3 & 4.


*Many codes require pipe hangers to be spaced every 10' (3.048 meters)
regardless of size. Check local codes.
Spacing and capacities are based on water filled pipe. Closer hanger spacing
may be required where additional valves and fittings increase the load.