S-NET Mini: Basic: MST-S3W Model: MST-S3W Model Code: MST-S3W
S-NET Mini: Basic: MST-S3W Model: MST-S3W Model Code: MST-S3W
Basic : MST-S3W
Model : MST-S3W
Model Code : MST-S3W
1. Precautions
2. Product Specifications
4. Troubleshooting
7. Wiring Diagram
8. Schematic Diagram
9. Reference Sheet
Refer to the service manual in the GSPN(see the rear cover) for the more information.
Contents
11. Precautions ................................................................................................................ 1-1
1-1. Precautions for the Service ......................................................................................... 1-1
1-2. Precautions for the Static Electricity and PL .................................................................. 1-1
1-3. Precautions for the Safety ........................................................................................... 1-1
Samsung Electronics 1
■ S-NET mini
1. Integrated control system which controls the system air conditioner installed in a small and medium-sized buildings.
2. Touch Screen's great usability and the user friendly interface provides easy control of the system air conditioner.
3. It can be used with Centralized controller, Transmitter and DMS.
3. ● System S/W
3. ● - WinCE .NET 5.0
3. ● - Device drivers
3. ● - LCD/Touch Screen
3. ● - NAND Flash
3. ● - Serial and Ethernet based communication
3. ● Application S/W
3. ● - Basic control
3. ● - Schedule management
3. ● - Error log enquiry
3. ● - Compatible communication with DMS , Centralized controller and Transmitter.
ⓐ DMS
S-NET mini
ⓑ Centralized
Controller
ⓒ
Transmitter Transmitter Transmitter
Max. 32 units
(DVM +)
◆ If you choose connection type ⓐ, you can use the S-NET 3 simultaneously.
- If you connect S-NET mini and the S-NET 3 simultaneously, choose ‘individual’ tracking.
◆ If you choose connection type ⓑ, you can not connect DMS to the Centralized controller.
◆ If you choose connection type ⓒ, you can not connect Centralized controller to the Transmitter.
User Interface Touch Screen's usability and intuitive user friendly GUI.
Schedule
Indoor unit operation schedule can be managed in weekly/daily period.
management
Zone setting and rename option can be used to easily control the indoor
Zone management
units.
Security password and lock function can be used to limit access to other
Security and lock
people.
Error log, connection status, cycle status of the indoor and outdoor units
DVM information
can be checked.
S/W
Peak power can be managed or monitored through the DMS that is Only available with
Peak power control
connected to the Peak transmitter. DMS connection
Extra fucntion Time setting, Volume control, IP setting, Stylus adjustment etc.
H/W Test function H/W Test program for S-NET mini is installed.
OS, SW
OS and SW update program is provided to update S-NET mini.
Update
+SCREW DRIVER
DMS should be powered on all the time. Check the DMS is turned on,
Is the DMS turned on?
and connect the DMS again.
Have you set DMS as your Check the communication setup from [System setup] →
communication device? [Communication setup].
Is Peak power management In Peak power management mode, 'Turning on the indoor unit' or
mode in operation? 'Changing operation mode to Cool/Auto/Dry' will be restricted.
Wasn’t the schedule made Any changes to common exception days does not affect previously
Common exception days are
before the common exception created schedule. Select Exception days on the schedule menu and
not applied.
days are set? edit common exception days to apply the common exception days,
S-NET mini display is Check if you can control the S-NET mini program is down. Press the Reset button on the side of
frozen. function. the product.
Remote controller is out of Did you disable wired/wireless Enable wired/wireless remote control from
control. remote control? [Indoor unit control].
No. Description
4 Reset
● Insert the SD memory card on the memory card slot located on the side of S-NET mini.
→ When the SD memory card is inserted, H/W Test window will appear automatically.
�
1 �
7
�
2 �
8
�
9
�
3
�
10
�
4
�
11
�
5
�
12
�
a
�
6 �
14 �
13
�
15
No. Description
a Status Window
2 Set IP Address
3 System Information (S/W Version information and MAC Address, IP setup, Memory usage)
5 Clear Password
7 SD Card Test
8 USB Test
9 Screen Calibartion
11 Sound Test
12 LED Test
14 Screen Clear
◆ IP address will change to 192.168.0.1 every time you access H/W Test menu.
Set IP Address(button�
2 ) before closing the H/W Test menu.
�
1 Set MAC Address
�
2 Set IP Address
�
3 System Information
● S/W version information, IP Address, and memory usage will appear on the status window.
�
4 Set System Time
◆ When you set the time, you should set the year in between 1980~2079. When you enter the year outside those range,
your time will not be applied.
�
5 Clear Password
�
6 Manage User Data
● System will backup user data file under ‘₩Snet_Storage Bin Sys’ directory.
Backup data file will be saved under ' Storage Card Backup Data' directory.
Backup data includes Zone management, Schedule management and System setup data.
�
6 Manage User Data (continued)
● Restore the user data on the SD memory card. (File source: Storage Card Backup Data).
�
7 SD Card Test
● SD Card Test will proceed in order of writing temporary file on SD memory card followed by validating the file.
�
8 USB Test
�
9 Calibration
�
10 Screen Test (Bright Test)
�
11 Sound Test
�
12 LED Test
● Test the LED by flickering the light twice on data indicator and the error indicator.
�
13 Client MAC Address
�
14 Screen Clear
�
15 Close
◆ IP address will change to 192.168.0.1 every time you access H/W Test menu.
◆ Set IP Address(button� 2 ) before closing the H/W Test menu.
Start
JACK1
YES
YES
C909 → 3.3V C915 → 1.3V
NO
End
Start
NO
Is the display white blank?
YES CN09
CN07
YES
NO
End
Start
Sound is working.
NO
YES CN02
NO
End
Start
CN08
YES
YES
End
Start
YES
YES
End
9
1
11
7
5
10
6
8
11
Parts List
6 5 4 a 3 8 2 1 b 7 d c 9 10
2 3 4
6
7 1
#1 Power connector
#2 LCD ASS’Y cable – LED Backlight
#3 LCD ASS’Y cable – Touch screen
#4 LCD ASS’Y cable – RGB Data
#5 Speaker connector
#6 LAN Port connector
#7 485 Communication terminal connector
#8 SD Card socket
❹
❸
No. Description
❶ Menu button
❸ Lock button
● What is an update?
Update is renewing the version of OS(Operating System) or Software(S-NET mini) used in S-NET mini for better function and the
performance.
WinCE WinCE is a variation of Microsoft’s Windows operating system for minimalist computers and embedded systems.
Boot-loader is the first software that runs once the power turns on. Main purpose of this program is to prepare for
Boot-loader
the operating system to operate normally.
◆ Image files for O/S and the Software(S-NET mini) should be saved on SD/MMS memory card.
◆ You need SD memory card reader to save O/S update files on to SD memory card.
● Side view
Reset button
USB(Device) port
SD card slot
USB(Host) port
1. Press and hold the [Menu] button and press the [Reset] button on the side of the product.
▶ You can restart the S-NET mini when you press [Reset] button.
❺ 2
❶
❻
❷ 3
❸
❹
No. Description
❹ Boot-loader version
❺ Menu cursor
❻ Select/Operate menu
◆ You cannot precede O/S update when the SD memory card is not inserted.
5. Select [1.Exit] and press Soft keyboard button when update is done.
▶ O/S update menu will disappear and S-NET mini will re-start.
❶ ❷
❸ ❹
No. Description
❹ Reset
2. Insert the SD memory card on the memory card slot located on the side of S-NET mini.
▶ When the SD memory card is inserted, H/W Test window will appear automatically.
2. Tap [Yes].
▶ Check the software version to be updated.
▶ Tap [No], if you do not want to update software.
5. Tap [Restore].
▶ When you tap [Restore], saved user data, Zone management, Schedule management and System setup data will be restored.
▶ You may skip this stage if you have not saved(backup) the user data.
This Service Manual is a property of Samsung Electronics Co., Ltd. © Samsung Electronics Co., Ltd. Jul. 2008.
Any unauthorized use of Manual can be punished under applicable Printed in Korea.
International and/or domestic law. Code No. DB98-29688A(1)