100% found this document useful (7 votes)
4K views2 pages

These Are Sheet Metal Troughs With Hinged or Removable Covers For Housing and Protecting Electrical Wires and Cables and in Which Conductors Are Laid in Place

These document contains questions about electrical wiring components, connections, and best practices. It asks about sheet metal enclosures for wiring like busways, cable ducts, and cable trays. It also asks about parameters for incandescent bulbs, proper wire termination techniques, types of electrical enclosures and fittings, why torque wrenches are used, common conduit types, conduit support fittings, dealing with temperature changes in raceways, and safety precautions for working on existing electrical installations. The document covers a range of topics relating to electrical wiring systems, components, and installation best practices.

Uploaded by

Nathaniel Aloba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (7 votes)
4K views2 pages

These Are Sheet Metal Troughs With Hinged or Removable Covers For Housing and Protecting Electrical Wires and Cables and in Which Conductors Are Laid in Place

These document contains questions about electrical wiring components, connections, and best practices. It asks about sheet metal enclosures for wiring like busways, cable ducts, and cable trays. It also asks about parameters for incandescent bulbs, proper wire termination techniques, types of electrical enclosures and fittings, why torque wrenches are used, common conduit types, conduit support fittings, dealing with temperature changes in raceways, and safety precautions for working on existing electrical installations. The document covers a range of topics relating to electrical wiring systems, components, and installation best practices.

Uploaded by

Nathaniel Aloba
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

1.

These are sheet metal troughs with hinged or removable covers for housing and protecting
electrical wires and cables and in which conductors are laid in place.
a. Busways
b. Wire ways
c. Cable ducts
d. Cable trays
2. most of the required electrical parameters apply to an incandescent bulb are
a. rated power and rated voltage
b. rated resistance and rated current
c. rated current and rated voltage
d. rated power and rated current
3. when tightening a terminal screw connection, the end of the wire should pass around the screw
in the same direction as the screw is turned so that
a. the wire will act as locknut
b. any pull on the wire will tighten the screw
c. the wire will not turn off
d. the screw can be removed more easily
4. a part providing an appropriate degree protection of equipment against contains external
influences and defined degree of protect against contacts with live parts any direction.
a. Cabinet
b. Enclosure
c. Panel board
d. Switch gear
5. Locknut, bushing and connectors are called electrical _____________.
a. Conduit
b. Fittings
c. Expander
d. Tighteners
6. Why is it necessary to use torque wrench in tightening bolted joints of copper bus bars inside
bus ducts and bus ways?
a. To prevent heating of the joints
b. To reduce the resistance in the joint
c. To make sure the joints are well tightened
d. To give the bolt allowance for thermal expansion
7. What is the commonly used conduit in service entrance?
a. PVC
b. EMT
c. RSC/IMC
d. Flex conduit
8. What is the types of fitting commonly used for exposed conduit support?
a. Conduit strap/clamp
b. Condulet
c. Connector
d. Lock nut and bushing
9. When raceways are exposed to widely different temperatures it should
a. Sealed
b. Bonded
c. Grounded
d. Isolated
10. Before adding to or altering an installation, you must ensure that
a. You are well familiar with the existing installation
b. Such work will not impair any part of the existing installation
c. Safety precautions are followed
d. All of the above