200Mhz Cursor Readout Analog Oscilloscope: Features

The document describes a 200MHz dual-channel oscilloscope. It has a microprocessor-based operating system that controls cursor readout and digitized panel settings. It provides on-screen readout of voltage, time, frequency and phase measurements. It also has auto-measurement functions for frequency, period, pulse width and duty cycle. The oscilloscope stores 10 user-defined instrument settings and has inputs for two channels with bandwidths up to 200MHz.

Uploaded by

dani385ar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views2 pages

200Mhz Cursor Readout Analog Oscilloscope: Features

The document describes a 200MHz dual-channel oscilloscope. It has a microprocessor-based operating system that controls cursor readout and digitized panel settings. It provides on-screen readout of voltage, time, frequency and phase measurements. It also has auto-measurement functions for frequency, period, pulse width and duty cycle. The oscilloscope stores 10 user-defined instrument settings and has inputs for two channels with bandwidths up to 200MHz.

Uploaded by

dani385ar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

200MHz CURSOR READOUT ANALOG OSCILLOSCOPE

OSCILLOSCOPES

OSCILLOSCOPES
The GOS-6200 is a 200MHz two-channel, dual-trace, portable oscilloscope designed for general
purpose use. A microprocessor-based operating system controls most of the functions of the instrument,
including cursor readout and convenient digitized panel settings. On-screen alphanumeric readout and
cursor functions are provided for voltage, time, frequency and phase measurement to extraordinary
operational convenience. It also has the function of TV Line select for trigger settings for NTSC, PAL
and SECAM. Auto-measurements include frequency, period, pulse width and duty cycle with auto-setting
function. Ten different user defined instrument settings can be saved and recalled without restriction.

The vertical deflection system has two input channels, each with 11 different basic deflection factors
from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps
from 20ns to 0.5s per division (delayed sweep, 50ms to 20ns per division). The trigger system provides
GOS-6200 (200MHz) stable triggering over the full bandwidth of the vertical deflection.

GOS-6200

FEATURES SPECIFICATIONS SPECIFICATIONS


CRT OUTPUT SIGNAL AUTO AND CURSOR
* 200MHz Bandwidth, Dual Channel, Delayed Type 6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers
8 x 10 div (1 div = 1 cm)
Trigger Signal Output
Calibrator Output
Voltage : approx. 25mV/div into 50 ; Frequency response : DC ~ 10MHz
1kHz square wave, 2Vpp +_ 2% MEASUREMENT FUNCTIONS
Sweep Accelerating Potential 14 kV approx.
CURSOR READOUT FUNCTION
* Auto Set Illumination Continuously adjustable
Z-axis input Coupling : DC Cursor Measurement Function V, V%, VdB, T, 1/ T, T%,
* Built-in 6 digits Universal Counter
Sensitivity: 5V or more Cursor Resolution 1/100 div
* Cursor Readout with 7 Measurements Maximum input voltage : 30V (DC + AC peak) at 1kHz or less Effective Cursor Range Vertical: + _ 4 div
_ 3div; Horizontal: +
* 10 Sets Memory for Front Panel Setting Save Bandwidth : DC ~ 5 MHz Panel Setting Display Vertical: V/div(CH1,CH2),UNCAL,ALT/CHOP/ADD,INV, probe factor,AC/DC/GND
& Recall VERTICAL SYSTEM Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, delay time , Hold-off
* TV-Line Selection (NTSC, PAL, SECAM) Trigger: source, coupling, slope, level, TV-V, TV-H
Sensitivity 2mV~5V/div, 11 step in 1-2-5 sequence Others: X-Y, lock, save/recall MEM 0-9
* Panel Setup Lock of Digital-Control Functions Sensitivity Accuracy _ 3% (5div at the center of display)
<
Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less of panel-indicated value AUTO MEASUREMENT FUNCTION
* Buzzer Alarm AUTO Mode : Frequency AUTO Mode : Period
Bandwidth(-3dB) DC~200MHz (5mV/div:DC~150MHz) ; (2mV/div:DC~20MHz) Parameter Function FREQ, PERIOD, + _ WIDTH, +_ DUTY (+ or - polarity selected by trigger slope)
* LED Indicators Rise Time 1.75ns (5mV/div:2.33ns, 2mV/div:17.5ns) Display Digits Max. 6-digits, decimal
* Trigger Signal Output Signal Delay Leading edge can be monitored Frequency Range 50Hz ~ 200MHz
* Z-axis Modulation Input Max. Input Voltage 400V(DC+AC peak) at 1kHz or less Accuracy 1kHz ~ 200MHz : + _ 0.01%; 50Hz ~ 1kHz : +
_ 0.05%
Input Coupling AC, DC, GND Measuring Sensitivity > 2 DIV (Measuring source selected from CH1 and CH2 as synchronous signal
* SMD Technology, High Stability and Reliability Input Impedance 1M + _ 2% // approx. 25pF sources)
Vertical Mode CH1,CH2,DUAL(CHOP/ALT), ADD, CH2 INV.
Bandwidth Limited 20MHz SPECIAL FUNCTION
Common-Mode Rejection Ratio 50:1 or better at 50kHz Auto Set Input Channel: CH1, CH2; Frequency Response 50Hz ~50MHz
Dynamic Range 8 div at 100MHz; 5div at 200MHz Panel Setting Save & Recall 10 sets
HORIZONTAL SYSTEM Panel Setups Lock Provided RISE Time ( T) Voltage ( V)
Horizontal Modes POWER SOURCE
MAIN(A), ALT, DELAY(B)
A(main) Sweep Time 20ns~0.5s/div, continuously variable (UNCAL) AC 100V/120V/230V + _ 10% , 50/60Hz
B(delay) Sweep Time 20ns~50ms/div DIMENSIONS & WEIGHT
Accuracy +
_ 3% ( +_ 5% at x 10 MAG)
Sweep Magnification x 10 (maximum sweep time 2ns/div)
310(W) x 150(H) x 470(D) mm ; Approx. 9kg AUTOSET FUNCTION
Hold Off Time Variable
Delay Time 1 s~5s ORDERING INFORMATION
Delay Jitter Better than 1:20000
Alternate Separation GOS-6200 200MHz Cursor Readout Analog Oscilloscope
Variable
TRIGGER ACCESSORIES :
Trigger Modes AUTO, NORM, TV User manual x 1, Power cord x 1
Trigger Source CH1, CH2, LINE, EXT, EXT/10 Probe-GTP-250A : 250MHz ( 10 : 1/1 :1 ) Switchable Passive Probe (one per channel)
Trigger Coupling AC, DC, HFR, LFR, NR OPTIONAL ACCESSORIES
Trigger Slope "+" or "-" polarity or TVsync polarity
Trigger Sensitivity GTC-001 Instrument Cart, 450(W) x 430(D) mm (120V Input Socket)
Mode Frequency INT EXT EXT/10 Before AUTOSET After AUTOSET
GTC-002 Instrument Cart, 330(W) x 430(D) mm (120V Input Socket)
GTL-110 Test Lead, BNC-BNC Heads Screen after unknown signal input. Optimum screen display after
10 Hz ~ 20 MHz 0.35 div 50 mV 500 mV
AUTO pressing a button.
20 MHz ~ 200 MHz 1.5 div 150 mV 1.5 V
DC ~ 20 MHz 0.35 div 50 mV 500 mV
NORM 20 MHz ~ 200 MHz 1.5 div 150 mV 1.5 V
TV sync signal 1 div 200 mV pp 2 V pp
TV-H, TV-V, FIELD/LINE SELECTOR
Trigger Level Range _ 4div or more; EXT : +
INT : + _ 0.4V or more; EXT/10 : +
_ 4V or more
TV Triggering Mode : TV-V, TV-H, TV-LINE
TV-Line Selection Standard Field 1 Field 2
NTSC (525H) 1H ~ 263H 1H ~ 262H
PAL (625H)
1H ~ 313H 1H ~ 312H
SECAM (625H)
Max. External Input Voltage 400V(DC+AC peak) at 1kHz
External Input Impedance _5% // approx.25pF
1M W +
X-Y OPERATION TV - H TV - L
Mode X-axis: selectable CH1, EXT, EXT/10 ; Y-axis: selectable CH1, CH2, CH1 and CH2
Sensitivity Accuracy 2mV~5V/div + _ 3%;EXT : 0.1V/div +
_ 5%; EXT/10 : 1V/div + _ 5%
X-axis Bandwidth DC~500kHz(-3dB)
Phase Error 3 or less from DC~50kHz

A27 Made to Measure. Good Will Instrument Co., Ltd. A28


200MHz CURSOR READOUT ANALOG OSCILLOSCOPE
OSCILLOSCOPES

OSCILLOSCOPES
The GOS-6200 is a 200MHz two-channel, dual-trace, portable oscilloscope designed for general
purpose use. A microprocessor-based operating system controls most of the functions of the instrument,
including cursor readout and convenient digitized panel settings. On-screen alphanumeric readout and
cursor functions are provided for voltage, time, frequency and phase measurement to extraordinary
operational convenience. It also has the function of TV Line select for trigger settings for NTSC, PAL
and SECAM. Auto-measurements include frequency, period, pulse width and duty cycle with auto-setting
function. Ten different user defined instrument settings can be saved and recalled without restriction.

The vertical deflection system has two input channels, each with 11 different basic deflection factors
from 2mV to 5V per division. The horizontal deflection system provides single, dual or delayed sweeps
from 20ns to 0.5s per division (delayed sweep, 50ms to 20ns per division). The trigger system provides
GOS-6200 (200MHz) stable triggering over the full bandwidth of the vertical deflection.

GOS-6200

FEATURES SPECIFICATIONS SPECIFICATIONS


CRT OUTPUT SIGNAL AUTO AND CURSOR
* 200MHz Bandwidth, Dual Channel, Delayed Type 6-inch rectangular type with internal graticule; 0%, 10%, 90% and 100% markers
8 x 10 div (1 div = 1 cm)
Trigger Signal Output
Calibrator Output
Voltage : approx. 25mV/div into 50 ; Frequency response : DC ~ 10MHz
1kHz square wave, 2Vpp +_ 2% MEASUREMENT FUNCTIONS
Sweep Accelerating Potential 14 kV approx.
CURSOR READOUT FUNCTION
* Auto Set Illumination Continuously adjustable
Z-axis input Coupling : DC Cursor Measurement Function V, V%, VdB, T, 1/ T, T%,
* Built-in 6 digits Universal Counter
Sensitivity: 5V or more Cursor Resolution 1/100 div
* Cursor Readout with 7 Measurements Maximum input voltage : 30V (DC + AC peak) at 1kHz or less Effective Cursor Range Vertical: + _ 4 div
_ 3div; Horizontal: +
* 10 Sets Memory for Front Panel Setting Save Bandwidth : DC ~ 5 MHz Panel Setting Display Vertical: V/div(CH1,CH2),UNCAL,ALT/CHOP/ADD,INV, probe factor,AC/DC/GND
& Recall VERTICAL SYSTEM Horizontal: s/div(MTB, DTB), UNCAL, x 10MAG, delay time , Hold-off
* TV-Line Selection (NTSC, PAL, SECAM) Trigger: source, coupling, slope, level, TV-V, TV-H
Sensitivity 2mV~5V/div, 11 step in 1-2-5 sequence Others: X-Y, lock, save/recall MEM 0-9
* Panel Setup Lock of Digital-Control Functions Sensitivity Accuracy _ 3% (5div at the center of display)
<
Vernier Vertical Sensitivity Continuously variable to 1/2.5 or less of panel-indicated value AUTO MEASUREMENT FUNCTION
* Buzzer Alarm AUTO Mode : Frequency AUTO Mode : Period
Bandwidth(-3dB) DC~200MHz (5mV/div:DC~150MHz) ; (2mV/div:DC~20MHz) Parameter Function FREQ, PERIOD, + _ WIDTH, +_ DUTY (+ or - polarity selected by trigger slope)
* LED Indicators Rise Time 1.75ns (5mV/div:2.33ns, 2mV/div:17.5ns) Display Digits Max. 6-digits, decimal
* Trigger Signal Output Signal Delay Leading edge can be monitored Frequency Range 50Hz ~ 200MHz
* Z-axis Modulation Input Max. Input Voltage 400V(DC+AC peak) at 1kHz or less Accuracy 1kHz ~ 200MHz : + _ 0.01%; 50Hz ~ 1kHz : +
_ 0.05%
Input Coupling AC, DC, GND Measuring Sensitivity > 2 DIV (Measuring source selected from CH1 and CH2 as synchronous signal
* SMD Technology, High Stability and Reliability Input Impedance 1M + _ 2% // approx. 25pF sources)
Vertical Mode CH1,CH2,DUAL(CHOP/ALT), ADD, CH2 INV.
Bandwidth Limited 20MHz SPECIAL FUNCTION
Common-Mode Rejection Ratio 50:1 or better at 50kHz Auto Set Input Channel: CH1, CH2; Frequency Response 50Hz ~50MHz
Dynamic Range 8 div at 100MHz; 5div at 200MHz Panel Setting Save & Recall 10 sets
HORIZONTAL SYSTEM Panel Setups Lock Provided RISE Time ( T) Voltage ( V)
Horizontal Modes POWER SOURCE
MAIN(A), ALT, DELAY(B)
A(main) Sweep Time 20ns~0.5s/div, continuously variable (UNCAL) AC 100V/120V/230V + _ 10% , 50/60Hz
B(delay) Sweep Time 20ns~50ms/div DIMENSIONS & WEIGHT
Accuracy +
_ 3% ( +_ 5% at x 10 MAG)
Sweep Magnification x 10 (maximum sweep time 2ns/div)
310(W) x 150(H) x 470(D) mm ; Approx. 9kg AUTOSET FUNCTION
Hold Off Time Variable
Delay Time 1 s~5s ORDERING INFORMATION
Delay Jitter Better than 1:20000
Alternate Separation GOS-6200 200MHz Cursor Readout Analog Oscilloscope
Variable
TRIGGER ACCESSORIES :
Trigger Modes AUTO, NORM, TV User manual x 1, Power cord x 1
Trigger Source CH1, CH2, LINE, EXT, EXT/10 Probe-GTP-250A : 250MHz ( 10 : 1/1 :1 ) Switchable Passive Probe (one per channel)
Trigger Coupling AC, DC, HFR, LFR, NR OPTIONAL ACCESSORIES
Trigger Slope "+" or "-" polarity or TVsync polarity
Trigger Sensitivity GTC-001 Instrument Cart, 450(W) x 430(D) mm (120V Input Socket)
Mode Frequency INT EXT EXT/10 Before AUTOSET After AUTOSET
GTC-002 Instrument Cart, 330(W) x 430(D) mm (120V Input Socket)
GTL-110 Test Lead, BNC-BNC Heads Screen after unknown signal input. Optimum screen display after
10 Hz ~ 20 MHz 0.35 div 50 mV 500 mV
AUTO pressing a button.
20 MHz ~ 200 MHz 1.5 div 150 mV 1.5 V
DC ~ 20 MHz 0.35 div 50 mV 500 mV
NORM 20 MHz ~ 200 MHz 1.5 div 150 mV 1.5 V
TV sync signal 1 div 200 mV pp 2 V pp
TV-H, TV-V, FIELD/LINE SELECTOR
Trigger Level Range _ 4div or more; EXT : +
INT : + _ 0.4V or more; EXT/10 : +
_ 4V or more
TV Triggering Mode : TV-V, TV-H, TV-LINE
TV-Line Selection Standard Field 1 Field 2
NTSC (525H) 1H ~ 263H 1H ~ 262H
PAL (625H)
1H ~ 313H 1H ~ 312H
SECAM (625H)
Max. External Input Voltage 400V(DC+AC peak) at 1kHz
External Input Impedance _5% // approx.25pF
1M W +
X-Y OPERATION TV - H TV - L
Mode X-axis: selectable CH1, EXT, EXT/10 ; Y-axis: selectable CH1, CH2, CH1 and CH2 Calle del Ebano #16625
Sensitivity Accuracy 2mV~5V/div + _ 3%;EXT : 0.1V/div +
_ 5%; EXT/10 : 1V/div + _ 5% Jardines de Chapultepec
X-axis Bandwidth DC~500kHz(-3dB) Tijuana B.C. Mexico
Phase Error 3 or less from DC~50kHz Tel. (664) 681 1130
Fax. (664) 681 1150
Tel. 01800 027-4848
www.finaltest.com.mx
A27 Made to Measure. Good Will Instrument Co., Ltd. A28