Photovoltaic
Content Photovoltaic
Inverter Page xx
DC-Disconnection Page xx
DC-String Protection Page xx
Surge Protection Page xx
Energy Management Page xx
1
Photovoltaic - Inverter
Inverter
- AC Nominal Output Power up to 4600 W
- Models IP65 for Outdoor use
- Transformerless Design
- RCMU and ENS integrated
- Maintenance-free
sg00210
2
±
Photovoltaic - Inverter ~
PV-Inverter Grid connected ISG
• Transformerless Design
• Equipped with MC3 plugs
• High efficiency
• Fanless
• LCD display
• GFCI integrated (RCMU)
• Works with monitoring software
• ENS meets VDE 0126-1-1
AC Output MC3 Type Designation Article No. Units per package
Indoor series IP43
sg00210
1500 W 1 pair ISG1I-1500/1 134753 1 / 14
2000 W 1 pair ISG1I-2000/1 134754 1 / 14
2800 W 1 pair ISG1I-2800/1 134755 1 / 12
3300 W 2 pairs ISG1I-3300/1 135522 1 / 12
4000 W 2 pairs ISG1I-4000/1 134756 1 / 12
Outdoor series IP65
sg00210
4000 W 3 pairs ISG1O-4000/1 134757 1 / 12
4600 W 3 pairs ISG3O-4600/1 134758 1/6
Explanactions:
MPP . . . . . . Maximum Power Point.
ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices.
GFCI . . . . . Ground Fault Current Interrupter.
RCMU . . . . Residual Current Monitoring Unit.
MC3 . . . . . . Multi Contact 3
3
±
Photovoltaic - Inverter ITALY ~
PV-Inverter Grid connected ISG...-I
• Transformerless Design
• Equipped with MC3 plugs
• High efficiency
• Fanless
• LCD display
• GFCI integrated (RCMU)
• Works with monitoring software
• ENS meets VDE 0126-1-1
• Meets requirements of DK5940
AC Output MC3 Type Designation Article No. Units per package
Indoor series IP43
sg00210
1500 W 1 pair ISG1I-1500/1-I 134759 1 / 14
2000 W 1 pair ISG1I-2000/1-I 134830 1 / 14
2800 W 1 pair ISG1I-2800/1-I 134831 1 / 12
3300 W 2 pairs ISG1I-3300/1-I 135523 1 / 12
4000 W 2 pairs ISG1I-4000/1-I 134832 1 / 12
Outdoor series IP65
sg00210
4000 W 3 pairs ISG1O-4000/1-I 134833 1 / 12
4600 W 3 pairs ISG3O-4600/1-I 134834 1/6
6000 W 3 pairs ISG1O-6000/1-I 134835 1/6
Explanations:
MPP . . . . . . Maximum Power Point
ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices.
Zwei voneinander unabhängige Einrichtungen zur Netzüberwachung mit zugeord-
neten allpoligen Schaltern in Reihe.
GFCI . . . . . Ground Fault Current Interrupter
RCMU . . . . Residual Current Monitoring Unit
MC3 . . . . . . Multi Contact 3
4
±
Photovoltaic - Inverter ~
Three-phase PV-Inverter grid connected I3G2O
• Transformerless Design
• With MC4 compatible plugs
• Maximum efficiency ≥97.5%
• Euro efficiency ≥97%
• MPPT efficiency >99%
• Lead-free, RoHS complied
• Graphical LCD display
• RCMU (GFCI) embedded
• Works with monitoring software
• ENS meets VDE 0126-1-1
• 2 MPPT-tracker
• IP65, Outdoor
• Grid interface regulation according VDE-AR-N 4105, VDE 0126-1-1/A1 (Germany), ENEL
Guide 2012 (Italy), CEI 0-21, RD1663 (Spain), G83/1-1, G59 Issue 2 (UK) and BDEW(MVD)
AC Output Type Designation Article No. Units per package
Outdoor series IP65
sg00210
10 kW I3G2O-10kW/2 167372 1
15 kW I3G2O-15kW/2 167373 1
20 kW I3G2O-20kW/2 167374 1
Explanactions:
MPP . . . . . . Maximum Power Point.
ENS . . . . . . Two independent main monitoring units with allocated all-pole switching devices.
GFCI . . . . . Ground Fault Current Interrupter.
RCMU . . . . Residual Current Monitoring Unit.
MC4 . . . . . . Multi Contact 4
5
Photovoltaic - DC-Disconnection
DC-Disconnectors
- Rated Voltage 1000 VDC
- Rated Operational Current up to 63 ADC
- P-SOL as component
wa_sg05409 wa_sg04709
- SOL as pre-wired Unit ready for connection
wa_sg00110 wa_sg06009
6
Photovoltaic - DC-Disconnection DC
DC Switch-disconnector
DC Switch-disconnector P-SOL 2poles
• Rated operational voltage 1000 VDC
• Utilization category DC-21A
wa_sg05409, wa_sg04709
Rated op. current Ie Type designation Article No. Units per package
20A P-SOL20 120934 1
30A P-SOL30 120935 1
63A P-SOL60 120936 1
Connection diagrams:
PV Array
Unearthed system Earthed system
PV Inverter
DC Switch-disconnector
DC Switch-disconnector SOL 2poles as pre-wired unit with protection
class II, degree of protection IP65
• Rated operational voltage 1000 VDC
• Utilization category DC-21A
• Rated operational current Ie of 20or 30 A
• Several versions – plugs MC3, MC4 or cable glands available
• Versions for 2 and 4 Stings (INPUT) available
Ie INPUT OUTPUT Type designation Article No. Units per package
wa_sg00110
MC4 version
20A 2xMC4 1xMC4 SOL20/2MC4 120915 1
20A 4xMC4 1xMC4 SOL20/4MC4 120916 1
30A 2xMC4 1xMC4 SOL30/2MC4 120922 1
30A 4xMC4 1xMC4 SOL30/4MC4 120923 1
Version with metrical cable glands
20A 2xM12 1xM16 SOL20/2MW 120919 1
30A 2xM12 1xM16 SOL30/2MW 120926 1
SOL20/2MC4 SOL20/4MC4
SOL30/2MC4 SOL30/4MC4
SOL20/2MV
SOL30/2MV
7
Photovoltaic - PV Off Switch, PV fireman's switch
PV Off Switch
• Degree of protection IP 65
• Tamper-proof to ISO 13850/EN 418
• Reset by pulling or turning
• Red enclosure upper section
Description Type designation Article No. Units per
M22-SOL-PVT45PMPI11_HPL M22-SOL-PVPL11-230Q_HPL
package
Complete with guard ring, 1 NO, 1 NC M22-SOL-PVT45PMPI11Q 150644 1
Complete with guard ring 2 NC M22-SOL-PVT45PMPI02Q 150645 1
Surface mount enclosure, black/red cover M22-SOL-IR1Q 150646 1
Guard ring, red, laser etched with SOLAR M22-SOL-XGPVQ 150647 1
Guard ring, red 1 M22-XGPVQ 150648 1
Pushbutton laser etched with SOLAR M22-SOL-PVT45P-MPIQ 150673 1
Complete 1 NO, 1 NC, can be sealed M22-SOL-PVLPL11-230Q 152627 1
PV fireman's switch SOL30-SAFETY
DC switch-disconnector
• Rated operational voltage 1000V
• Utilization category DC-21A
• Rated operational current Ie 30A
• Remote release by undervoltage release 230V, 50Hz
• Feedback of the switching status by auxiliary contacts 1NO and 1NC
• Several versions - plugs MC3, MC4 or metric glands available
Ie INPUT OUTPUT Type designation Article No. Units per
package
SOL30-SAFETY_HPL
30A 2xMC3 1xMC3 SOL30-SAFETY/2MC3-U(230V50HZ) 144121 1
30A 2xMC4 1xMC4 SOL30-SAFETY/2MC4-U(230V50HZ) 144122 1
30A 2xM12 1M16 SOL30-SAFETY/2MV-U(230V50HZ) 144123 1
Connection diagrams:
8
Photovoltaic - DC String Protection
DC-String Protection
- Rated Voltage up to 900 VDC
- Rated Current up to 63 ADC
- PKZ-SOL elektromechanical Circuit Breaker
wa_sg05409 wa_sg04709
- FCFDC10DI-SOL Fuse-Disconnector and Fuse-links
wa_sg00210
9
Photovoltaic - DC String Protection DC
DC String circuit breaker
DC String circuit breaker PKZ-SOL 2poles
• Rated operational voltage 900 VDC
• Rated current In 12, 20, 30, 40, 50 and 63 A
• For permissible string short-circuit currents Isc of 5 up to 47 A
wa_sg05409, wa_sg04709 Ie Isc Type designation Article No. Units per package
4A 1.6-3A PKZ-SOL4 144069 1
7A 2.6-5A PKZ-SOL7 144120 1
12A 5-9A PKZ-SOL12 120937 1
20A 9-15A PKZ-SOL20 120938 1
30A 15-22A PKZ-SOL30 120939 1
Connection diagrams:
PV String
Unearthed system Earthed system
DC-Disconnection / PV Inverter
10
Photovoltaic - DC String Protection DC C
Fuse-Disconnector (empty) FCFDC10DI-..-SOL
• String protection of PV generator
• The visual tripping indicator indicates the tripped fuse-link
50-400 V flashing
400-1000 V permanent light
• Rated operational voltage 1000 VDC
• For cylindrical fuse-links photovoltaic application
• Lead-sealable
Number of Poles / Size Type Designation Article No. Units per package
wa_sg00210
Size 10x38 FCFDC10DI, Rated operational current 25 A DC
without Visual Tripping Indicator
1 10x38 FCFDC10DI-1-SOL 137256 12 / 108
2 10x38 FCFDC10DI-2-SOL 137257 6 / 54
with Visual Tripping Indicator
1 10x38 FCFDC10DI-1L-SOL 137258 12 / 108
2 10x38 FCFDC10DI-2L-SOL 137259 6 / 54
Application Photovoltaic
Earthed System
FCFDC10DI-1-SOL FCFDC10DI-1L-SOL
Unearthed System
FCFDC10DI-1-SOL FCFDC10DI-2L-SOL
11
Photovoltaic - DC String Protection C
Cylindrical Fuse-links
Size / Rated current / Rated voltage Type Designation Article No. Units per package
Fuse-Links ASFLC10-..A-gPV-SOL Photolvoltaic application
SG11008
10x38 2A 1000 V DC ASFLC10-2A-gPV-SOL 137279 10 / 500
10x38 4A 1000 V DC ASFLC10-4A-gPV-SOL 137280 10 / 500
10x38 6A 1000 V DC ASFLC10-6A-gPV-SOL 137281 10 / 500
10x38 8A 1000 V DC ASFLC10-8A-gPV-SOL 137282 10 / 500
10x38 10 A 1000 V DC ASFLC10-10A-gPV-SOL 137283 10 / 500
10x38 12 A 1000 V DC ASFLC10-12A-gPV-SOL 137284 10 / 500
10x38 16 A 1000 V DC ASFLC10-16A-gPV-SOL 137285 10 / 500
10x38 20 A 1000 V DC ASFLC10-20A-gPV-SOL 137286 10 / 500
10x38 25 A 900 V DC ASFLC10-25A-gPV-SOL 137287 10 / 500
PV-fuse-link selection:
À Maximum DC Operating voltage of the fuse-link must be:
1,2 x Voc of string
Á Rated current In of the fuse-link must be higher or equal than:
1,5 x Isc
Isc . . . . short circuit current of PV-module
Voc . . . open circuit voltage of string
12
Photovoltaic - Surge Protection
Surge Protection
DC - Photovoltaic systems up to 1000 VDC
- For single and three phase Grid feeding
AC
SG11009 SG11309
DC
sg13309 SG13609
AC
13
Photovoltaic - Surge Protection DC
SPD-type T2 (Class C)
Max. Cont. Op. Volt. UC In ( Type Designation Article No. Units per package
Plug-in Surge Arrester SPPT2PA for Photovoltaic application
SG11009
For earthed systems
600 V DC SPPT2PA-600-2PE 132663 1 / 60
1000 V DC SPPT2PA-1000-2PE 132664 1 / 60
with auxiliary switch
1000 V DC SPPT2PA-1000-2PE-AX 132666 1 / 60
For unearthed systems
SG11309
600 V DC SPPT2PA-600-2+1PE 132661 1 / 40
1000 V DC SPPT2PA-1000-2+1PE 132662 1 / 40
with auxiliary switch
1000 V DC SPPT2PA-1000-2+1PE-AX 132665 1 / 40
Inserts for replacement
600 V DC À SPPT2PA-600 132667 1
1000 V DC À SPPT2PA-1000 132668 1
1100 V DC Á SPPT2PA-1100 132669 1
VOC ≤ Uc: Open circuit voltage of PV-Generator shall be equal or less than maximum
continuous operating voltage of Surge Protective Device (SPD) to prevent its
damage.
VOC . . . . . .Open circuit voltage of PV-Generator.
UC . . . . . . .Maximum continuous operating voltage of SPD.
Attention: Even at switched off DC-Disconnector system stays under high voltage!
Before mounting ensure de-energizing and check zero-potential.
Earthed system Unearthed system
SPPT2PA-600-2PE SPPT2PA-600-2+1PE
SPPT2PA-1000-2PE(-AX) SPPT2PA-1000-2+1PE(-AX)
L- L- L+
14
Photovoltaic - Surge Protection DC
SPD-type T2 (Class C)
PV Surge Protective Device SOL-SP as pre-wired unit with protection
class II, degree of protection IP65
• For unearthed Photovoltaic systems up to 600 VDC and 1000 VDC
• Rated operational current Ie=30 ADC at versions MC3, MC4
• Rated operational current Ie=32 ADC at version with metrical cable glands
• PE-conductor has to be connected direct to the surge protective device
• PE terminal – metrical cable gland M16 in the enclosure for PE-conductor
Voc INPUT OUTPUT Type designation Article No. Units per package
wa_sg06509
MC3 version
600VDC 2xMC3 1xMC3 SOL-SP600U/2MC3 144124 1
1000VDC 2xMC3 1xMC3 SOL-SP1000U/2MC3 144127 1
MC4 version
600VDC 2xMC4 1xMC4 SOL-SP600U/2MC4 144125 1
1000VDC 2xMC4 1xMC4 SOL-SP1000U/2MC5 144128 1
Version with metrical cable glands
600VDC 2xM16 1xM16 SOL-SP600U/2MV 144126 1
1000VDC 2xM16 1xM16 SOL-SP1000U/2MV 144129 1
VOC ≤ Uc: Open circuit voltage of PV-Generator shall be equal or less than maximum
continuous operating voltage of Surge Protective Device (SPD) to prevent its
damage.
VOC . . . . . .Open circuit voltage of PV-Generator.
UC . . . . . . .Maximum continuous operating voltage of SPD.
Attention: Even at switched off DC-Disconnector system stays under high voltage!
Before mounting ensure de-energizing and check zero-potential.
Connection Example:
Protected Area
PE-conductor has to be
layed seperately to con-
DC-Disconnection ductors of protected area
PV Inverter
15
Photovoltaic - Surge Protection AC
SPD-type T2 (Class C)
Max. Cont. Op. Volt. UC In (8/20)µs Type Designation Article No. Units per package
sg13309
Plug-in surge arrester SPMT2PA, 1- to 4-pole
1pole 280VAC 1x20kA SPMT2PA-280/1 131755 12 / 120
2pole 280VAC 2x20kA SPMT2PA-280/2 131756 1 / 60
3pole 280VAC 3x20kA SPMT2PA-280/3 131757 1 / 40
4pole 280VAC 4x20kA SPMT2PA-280/4 131758 1 / 30
1pole 335VAC 1x20kA SPMT2PA-335/1 131759 12 / 120
2pole 335VAC 2x20kA SPMT2PA-335/2 131760 1 / 60
3pole 335VAC 3x20kA SPMT2PA-335/3 131761 1 / 40
4pole 335VAC 4x20kA SPMT2PA-335/4 131762 1 / 30
1+1p – – SPMT2PA-1+NPE 131773 1 / 60
3+1p – – SPMT2PA-3+NPE 131774 1 / 30
SG13109
Inserts SPMT2PA for replacement
Insert 1-pole
Insert 280VAC 20kA SPMT2PA-280 131778 4 / 120
Insert 335VAC 20kA SPMT2PA-335 131779 4 / 120
Insert N-PE 260VAC 30kA SPMT2PA-NPE 131783 4 / 120
Description Type designation Article No. Units per package
SG12809 Auxiliary Switch
for SPMT2PA ASAUXSC-SPM 131785 4 / 120
SG12909
Lead-through terminal for SPMT2PA
ASLTT-63 131784 12 / 120
16
Photovoltaic - Energy Management
Energy Management
- Energy sensors AC up to 100A
- Room-Manager with Energy visualisation
- Adapter RS232 to USB Interface
Wireless Data transmission
rf09410 rf05410
Data transmission via Data cable with Adapter RS232 to USB
rf01506
17
Photovoltaic - RF System - Flush-mounted devices
Design Type designation Article No. Units per package
RF05410
Energy sensor
• The "energy sensor" is used to record the solar energy converted in the PV inverter and
to forward this information to the Room-Manager equipped with "Energy management
function". This type of device is used for capacities of 3-3680W. It is used to determine
current (A), voltage (V), power (kW) and energy (kWh). The "energy sensor" is preferably
connected at the feeding point in the electrical system. The device is mounted in the
switch box, the branch-off box, or the installation box.
• Warning: The device is not calibrated and is thus not suitable for billing purposes!
0,42VA/230VAC, CEMU-01/04 136477 1
Measuring range 3-3680 W
(max. 16A)
Design Type designation Article No. Units per package
RF06510 Energy sensor with external sensor
• The "energy sensor with external sensor" is used to record the solar energy converted in
the PV inverter and to forward this information to the Room-Manager equipped with
"Energy management function". This type of device is used for larger capacities of 15W -
23kW. It is used to determine current (A), voltage (V), power (kW) and energy (kWh). The
energy sensor's external sensor is connected through the supply line, preferably at the
feeding point in the electrical system. The device is mounted in the switch box, the
branch-off box, or the installation box.
• Warning: The device is not calibrated and is thus not suitable for billing purposes!
0,42VA/230VAC, CEMU-01/05 136476 1
Measuring range ext. sensor
15 W - 23 kW (max. 100A)
18
Photovoltaic - RF System - Surface mounted devices
Design Type designation Article No. Units per package
rf09410 Room-Manager: white, 1 VA, 230 VAC, without Bluetooth
• The "Room-Manager" is a central display and operating device. In connection with the
energy sensors (with or without external sensors), the solar energy emitted by the
PV inverter is displayed. In addition, the device offers thoroughly tested applications such
as heating and cooling for individual rooms, ventilation, time functions, shading, safety,
etc., to achieve a modern electrical installation. The "Room-Manager" communicates with
all devices that are part of the Eaton RF system. The most modern touch- button sensor
technology makes it possible for the user to easily operate the system on site and to
program all parameters (e.g. time settings, temperature, etc.) The back-lighted graphic
display guarantees a simple and concise display of the most important information for
the end client. The device is to be surface-mounted on a wall. Alternatively, the device
can be affixed to a 55 mm or 68 mm switch box, branch-off box, or installation box.
The integrated IR interface is used for system updates or to expand functions. The device
feed is carried out through the power supply line.
• Note: In order to obtain the exact measurement and display of the temperature, use the
reference measuring device to determine the difference and then adjust the "Offset" in
the MRF system.
Room-Manager: Energy management
4 counter inputs (impulse counters or energy sensor), e.g. solar energy, electrical energy,
water, gas, etc.
Per input: Unit of measurement, count constant, base value, costs, CO2 emissions
Per input: Graphic display of progression during diverse time periods
(1 day, 7 days, 30 days, 12 months)
The display is adjustable
Each input allows 1 threshold value followed by an "action in case thisvalue is exceeded";
the limit value can be adjusted
Overview display of up to 3 different counter inputs
Room-Manager: Comfort management
2 local buttons, freely assignable
3 rooms for 1-level heating/cooling, adjustable time-temperature programme, target/actual
temperature display, operating modes can be selected, integration of 3 window contacts
per room
1 1-level ventilation, adjustable time programme, operating modes can be selected,
manual control
1 time and date display, automatic switch for daylight saving times in summer/winter
10 inputs, displays for temperature, humidity, light intensity, etc.
10 outputs, display and operation of electrical consumers
1 outdoor temperature, max./min/trend display, re-setting of the trend display
3 timers, adjustable time programme, operating modes can be selected, manual control
3 shading units with time programme and manual control, time programme is adjustable
1 holiday function, time and date are adjustable
1 presence simulator, settings adjustable for a max. of 10 consumers, time and activation
function
3 logic operations with 2 inputs each, AND/OR connection
2 scenes with 6 functions each, function is adjustable
1 request for total heating
1 request for total cooling
Battery status display and advance warning for all battery-operated devices that are
assigned to the Room-Manager
Software update conducted via IRDA
Adjustable password protection
Multi-language menu (depending upon article number)
General settings
Room-Manager: Safety management (additional function)
This fee-based function can be activated at www.moeller.at
2 separate areas can be monitored (e.g. indoors, outdoors, upper floor, etc.)
2 areas can be activated/deactivated individually or together
3 inputs to activate/deactivate, alternatively 4-digit codes can be used
10 additional inputs for safety (motion detectors, window contacts, sensors, etc.)
2 outputs for "Safety" alert purposes (sirens, flashing lights)
5 additional inputs for smoke detectors, regardless of whether Safety function is
activated/deactivated
1 output for "Smoke detector" alert (sirens, flashing lights)
Adjustable time delay for activation/deactivation upon entering/leaving a room
Attention: This is a warning function, not a smoke/fire alarm or other alarm system!!!
GB,NO,SE,FI CRMA-00/03 118783 1
GB,NL,FR,DE,IT CRMA-00/04 118784 1
GB,RO,HU,PL,TR CRMA-00/05 118785 1
GB,DE,CZ,GR CRMA-00/06 118786 1
19
Photovoltaic - Energy Management
Design Type designation Article No. Units per package
RF01506 USB-RS232 Adapter cable
• The "USB-RS232 Adapter cable" is used to connect the PV inverter (with RS232 interface)
to the laptop/notebook/PC (with USB interface). In this manner, all data from the PV
inverter can be evaluated by the "Watch-SOL Software".
CRSZ-00/03 104932 1
Design Type designation Article No. Units per package
RF03107 DIN-rail-clip
• The energy sensor (with or without external sensor) can be attached to the "DIN-rail-clip"
in order to snap this combination onto any possible DIN-rail. Note: Do not use metal dis-
tribution boards under any circumstances since metal can block the radio signal!!!
Info: The price and the order number refer to one "DIN-rail-clip" unit. We cannot
deliver single units! Therefore, please order at least one package (10 units) or a multiple
thereof.
CMMZ-00/30 135529 10