TRANSVERSAL
SIZE OF BEAMS
b (mm) h (mm)
ROOF LEVEL 3500 4000
THIRD FLOOR 3500 4000
SECOND
FLOOR 3500 4000
SIZE OF COLUMNS
b (mm) h (mm)
THIRD FLOOR 3500 3500
SECOND
FLOOR 3500 3500
FIRST FLOOR 3500 3500
HEIGHT
(mm)
THIRD TO
3500
ROOF
SECOND TO
3500
THIRD FLOOR
GROUND TO
SECOND 3250
FLOOR
Computation for stiffness Factor
FOR COLUMNS
k
Third Floor 357292 mmx10^4
Second Floor 357292 mmx10^4
Ground Floor 384776
FOR mmx10^4
BEAMS
For Second Floor
spa
1 2 3 4 5 6 7
n
k 233333 933333 233333 933333 233333 933333 266667
For Third Floor
spa
1 2 3 4 5 6 7
n
k 233333 933333 233333 933333 233333 933333 266667
For Roof Level
spa
1 2 3 4 5 6 7
n
k 233333 933333 233333 933333 233333 933333 266667
GIRDER FACTOR – SECOND FLOOR
Gf 9 - 10 0.761
Gf 10 - 9 0.389
Gf 10 - 11 0.389
Gf 11 - 10 0.389
Gf 11 - 12 0.389
Gf 12 - 11 0.389
Gf 12 - 13 0.389
Gf 13 - 12 0.389
Gf 13 - 14 0.389
Gf 14 - 13 0.389
Gf 14 - 15 0.389
Gf 15 - 14 0.382
Gf 15 - 16 0.382
Gf 16 - 15 0.736
Gf 16 - 0 0.000
Gf 0 16 0.000
COLUMN FACTOR- SECOND FLOOR
1.00
Cf 1 - 9
0
0.23
Cf 9 - 1
9
1.00
Cf 2 - 10
0
0.61
Cf 10 - 2
1
1.00
Cf 3 - 11
0
0.61
Cf 11 - 3
1
1.00
Cf 4 - 12
0
0.61
Cf 12 - 4
1
1.00
Cf 5 - 13
0
0.61
Cf 13 - 5
1
1.00
Cf 6 - 14
0
0.61
Cf 14 - 6
1
1.00
Cf 7 - 15
0
0.61
Cf 15 - 7
8
1.00
Cf 8 - 16
0
0.26
Cf 16 8
4
GIRDER FACTOR THIRD FLOOR
Gf 17 - 18 0.754
Gf 18 - 17 0.380
Gf 18 - 19 0.380
Gf 19 - 18 0.380
Gf 19 - 20 0.380
Gf 20 - 19 0.380
Gf 20 - 21 0.380
Gf 21 - 20 0.380
Gf 21 - 22 0.380
Gf 22 - 21 0.380
Gf 22 - 23 0.380
Gf 23 - 22 0.373
Gf 23 - 24 0.373
Gf 24 - 23 0.728
Gf 24 - 0 0.000
Gf 0 24 0.000
COLUMN FACTOR THIRD FLOOR
0.23
Cf 9 - 17
9
0.24
Cf 17 - 9
6
0.61
Cf 10 - 18
1
0.62
Cf 18 - 10
0
0.61
Cf 11 - 19
1
0.62
Cf 19 - 11
0
Cf 12 - 20 0.61
1
0.62
Cf 20 - 12
0
0.61
Cf 13 - 21
1
0.62
Cf 21 - 13
0
0.61
Cf 14 - 22
1
0.62
Cf 22 - 14
0
0.61
Cf 15 - 23
8
0.62
Cf 23 - 15
7
0.26
Cf 16 - 24
4
0.27
Cf 24 16
2
GIRDER FACTOR ROOF LEVEL
Gf 25 - 26 0.605
Gf 26 - 25 0.234
Gf 26 - 27 0.234
Gf 27 - 26 0.234
Gf 27 - 28 0.234
Gf 28 - 27 0.234
Gf 28 - 29 0.234
Gf 29 - 28 0.234
Gf 29 - 30 0.234
Gf 30 - 29 0.234
Gf 30 - 31 0.234
Gf 31 - 30 0.229
Gf 31 - 32 0.229
Gf 32 - 31 0.573
Gf 32 - 0 0.000
Gf 0 32 0.000
COLUMN FACTOR – ROOF LEVEL
0.24
Cf 17 - 25
6
0.39
Cf 25 - 17
5
0.62
Cf 18 - 26
0
0.76
Cf 26 - 18
6
0.62
Cf 19 - 27
0
0.76
Cf 27 - 19
6
0.62
Cf 20 - 28
0
0.76
Cf 28 - 20
6
0.62
Cf 21 - 29
0
0.76
Cf 29 - 21
6
0.62
Cf 22 - 30
0
0.76
Cf 30 - 22
6
0.62
Cf 23 - 31
7
0.77
Cf 31 - 23
1
0.27
Cf 24 - 32
2
0.42
Cf 32 - 24
7
GIRDER MOMENT FACTOR – SECOND LEVEL
Gf 9 - 10 223066.348
Gf 10 - 9 179666.410
Gf 10 - 11 545066.472
Gf 11 - 10 545066.472
Gf 11 - 12 136266.472
Gf 12 - 11 136266.472
Gf 12 - 13 545066.472
Gf 13 - 12 545066.472
Gf 13 - 14 136266.472
Gf 14 - 13 136266.472
Gf 14 - 15 541333.140
Gf 15 - 14 538533.141
Gf 15 - 16 200000.250
Gf 16 - 15 247200.309
Gf 16 - 0 0.000
Gf 0 16 0.000
COLUMN MOMENT FACTOR - SECOND LEVEL
Cf 1 - 9 430949.12000
Cf 9 - 1 284349.46400
Cf 2 - 10 502517.45600
Cf 10 - 2 427486.13600
Cf 3 - 11 502517.45600
Cf 11 - 3 427486.13600
Cf 4 - 12 502517.45600
Cf 12 - 4 427486.13600
Cf 5 - 13 502517.45600
Cf 13 - 5 427486.13600
Cf 6 - 14 502517.45600
Cf 14 - 6 427486.13600
Cf 7 - 15 503671.78400
Cf 15 - 7 430179.56800
Cf 8 - 16 435566.43200
Cf 16 8 293968.86400
GIRDER MOMENT FACTOR – THIRD LEVEL
Gf 17 - 18 220266.352
Gf 18 - 17 176633.081
Gf 18 - 19 531999.810
Gf 19 - 18 531999.810
Gf 19 - 20 132999.810
Gf 20 - 19 132999.810
Gf 20 - 21 531999.810
Gf 21 - 20 531999.810
Gf 21 - 22 132999.810
Gf 22 - 21 132999.810
Gf 22 - 23 529199.811
Gf 23 - 22 525466.479
Gf 23 - 24 196533.579
Gf 24 - 0 244000.305
Gf 24 - 0 0.000
COLUMN MOMENT FACTOR – THIRD LEVEL
Cf 9 - 17 129339.704
Cf 17 - 9 130768.872
Cf 10 - 18 329065.932
Cf 18 - 10 330852.392
Cf 11 - 19 329065.932
Cf 19 - 11 330852.392
Cf 12 - 20 329065.932
Cf 20 - 12 330852.392
Cf 13 - 21 329065.932
Cf 21 - 13 330852.392
Cf 14 - 22 329065.932
Cf 22 - 14 330852.392
Cf 15 - 23 332996.144
Cf 23 - 15 334425.312
Cf 16 - 24 142916.800
Cf 24 16 144345.968
GIRDER MOMENT FACTOR – ROOF LEVEL
Gf 25 - 26 168466.426
Gf 26 - 25 125299.821
Gf 26 - 27 327599.883
Gf 27 - 26 327599.883
Gf 27 - 28 81899.883
Gf 28 - 27 81899.883
Gf 28 - 29 327599.883
Gf 29 - 28 327599.883
Gf 29 - 30 81899.883
Gf 30 - 29 81899.883
Gf 30 - 31 325733.217
Gf 31 - 30 322933.218
Gf 31 - 32 137600.172
Gf 32 - 31 183466.896
Gf 32 - 0 0.000
Gf 0 32 0.000
COLUMN MOMENT FACTOR – ROOF LEVEL
Cf 17 - 25 158459.002
Cf 25 - 17 185077.256
Cf 18 - 26 358363.876
Cf 26 - 18 384446.192
Cf 19 - 27 358363.876
Cf 27 - 19 384446.192
Cf 20 - 28 358363.876
Cf 28 - 20 384446.192
Cf 21 - 29 358363.876
Cf 29 - 21 384446.192
Cf 22 - 30 358363.876
Cf 30 - 22 384446.192
Cf 23 - 31 361758.150
Cf 31 - 23 387483.174
Cf 24 - 32 173465.266
Cf 32 24 201155.396
FINAL MOMENTS
Column Moment Girder Moment
Ground Floor
Cf 1 - 9 5.171 Gf 9 - 10 5.223
Cf 9 - 1 3.412 Gf 10 - 9 2.414
Cf 2 - 10 6.030 Gf 10 - 11 7.323
Cf 10 - 2 5.130 Gf 11 - 10 7.790
Cf 3 - 11 6.030 Gf 11 - 12 1.947
Cf 11 - 3 5.130 Gf 12 - 11 1.947
Cf 4 - 12 6.030 Gf 12 - 13 7.790
Cf 12 - 4 5.130 Gf 13 - 12 7.790
Cf 5 - 13 6.030 Gf 13 - 14 1.947
Cf 13 - 5 5.130 Gf 14 - 13 1.958
Cf 6 - 14 6.030 Gf 14 - 15 7.779
Cf 14 - 6 5.130 Gf 15 - 14 7.164
Cf 7 - 15 6.044 Gf 15 - 16 2.660
Cf 15 - 7 5.162 Gf 16 - 15 5.529
Cf 8 - 16 5.227 Gf 16 - 0 0.000
Cf 16 8 3.528 Gf 0 16 0.000
Column Moment Girder Moment
Second Floor
Cf 9 - 17 1.811 Gf 17 - 18 2.782
Cf 17 - 9 1.831 Gf 18 - 17 1.425
Cf 10 - 18 4.607 Gf 18 - 19 4.195
Cf 18 - 10 4.632 Gf 19 - 18 4.300
Cf 11 - 19 4.607 Gf 19 - 20 0.926
Cf 19 - 11 4.632 Gf 20 - 19 0.926
Cf 12 - 20 4.607 Gf 20 - 21 3.706
Cf 20 - 12 4.632 Gf 21 - 20 3.706
Cf 13 - 21 4.607 Gf 21 - 22 0.926
Cf 21 - 13 4.632 Gf 22 - 21 0.930
Cf 14 - 22 4.607 Gf 22 - 23 3.702
Cf 22 - 14 4.632 Gf 23 - 22 3.408
Cf 15 - 23 4.662 Gf 23 - 24 1.274
Cf 23 - 15 4.682 Gf 24 - 0 2.021
Cf 16 - 24 2.001 Gf 24 - 0 0.000
Cf 24 16 2.021 Gf 0 24 0.000
Column Moment Girder Moment
Third Floor
Cf 17 - 25 0.951 Gf 25 - 26 1.110
Cf 25 - 17 1.110 Gf 26 - 25 0.638
Cf 18 - 26 2.150 Gf 26 - 27 1.669
Cf 26 - 18 2.307 Gf 27 - 26 1.846
Cf 19 - 27 2.150 Gf 27 - 28 0.461
Cf 27 - 19 2.307 Gf 28 - 27 0.461
Cf 20 - 28 2.150 Gf 28 - 29 1.846
Cf 28 - 20 2.307 Gf 29 - 28 1.846
Cf 21 - 29 2.150 Gf 29 - 30 0.461
Cf 29 - 21 2.307 Gf 30 - 29 0.464
Cf 22 - 30 2.150 Gf 30 - 31 1.843
Cf 30 - 22 2.307 Gf 31 - 30 1.630
Cf 23 - 31 2.171 Gf 31 - 32 0.695
Cf 31 - 23 2.325 Gf 32 - 31 1.207
Cf 24 - 32 1.041 Gf 32 - 0 0.000
Cf 32 24 1.207 Gf 0 32 0.000