0% found this document useful (0 votes)
91 views12 pages

t7bHSpK2 - VTO2202F-P Quick Install Guide OCT2019

1. The document provides instructions for configuring a home video intercom system using VTO cameras and VTH monitors connected via a VTNS1060A PoE switch. 2. It describes initializing the VTO cameras by connecting directly to them and walking through a setup wizard to configure network settings and passwords. 3. The instructions also cover configuring the VTH monitors by accessing their on-screen menus to set the network settings, room numbers, and configure the VTHs to register with the VTO cameras.

Uploaded by

Deltaz AZ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
91 views12 pages

t7bHSpK2 - VTO2202F-P Quick Install Guide OCT2019

1. The document provides instructions for configuring a home video intercom system using VTO cameras and VTH monitors connected via a VTNS1060A PoE switch. 2. It describes initializing the VTO cameras by connecting directly to them and walking through a setup wizard to configure network settings and passwords. 3. The instructions also cover configuring the VTH monitors by accessing their on-screen menus to set the network settings, room numbers, and configure the VTHs to register with the VTO cameras.

Uploaded by

Deltaz AZ
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

V1

Official UK distribution partner

VTO2202F-P
QUICK INSTALL
GUIDE
Please read this document before installation

tel: +44 (0)1457 874 999 | fax: +44 (0)1457 829 201 | email: [email protected] | web: www.cop-eu.com
HOME SYSTEM CONFIGURATION
When configuring a home VDP system, all devices should first be connected together. Usually, this is done by connecting both the
camera unit (VTO) and monitor unit (VTH) to the VTNS1060A PoE switch.

The VTNS1060A is a 24v passive PoE unit, this is a different type of PoE than that seen on conventional IP devices. As such, both the
VTO2000A and VTH1550CH can only be used with 24v passive PoE or by connecting a 12/24v DC power supply to the power input
terminals on the units.

Example 1
VTO2202F-P PoE VTNS1060A VTH Passive PoE Monitor
Module Switch Switch

802.3af PoE 24v PoE

Ethernet Link

Example 2
Camera Module
PoE VTNS1060A Main VTH Monitor
Switch Switch

802.3af PoE
24v PoE

Ethernet Link

VTO CONNECTIONS
Network
Tamper Connection
Switch
NET

Inputs &
Outputs
ALARM_COM

DOOR_COM
ALARM_ON

EOC1(GND)

DOOR_NO
DOOR BUTTON

DOOR_NC
EOC1(+12)

DOOR_FB
12V_OUT
RS485_B
RS485_A
GND

GND

Tamper Switch Sounds an alarm in the event that the VTO unit is tampered with

Network Connection Connect the supplied RJ45 adapter cable to this port

+12v Used when not powering the VTO via PoE, connect the 12v or 24v DC positive supply to this
terminal

GND Ground connection for 12v DC negative supply and other inputs

12v Out DC 12v continuous output for auxiliary device (100mA max)

Door Button Input to connect a switch such as a push button for releasing the door lock

Door FB Input for door contact to check if the door is closed before engaging lock

Door NO/NC/COM Relay output used when unlocking door

RS485 A/B RS485 Bus for connecting secondary lock controller DEE1010B

2 Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
INITIALISATION
The first step in configuring the VTO cameras is to discover the cameras on the network so the IP address can be configured. By default
all VTO units are shipped on an IP address of 192.168.1.110 and in an uninitialised state.

Before the VTO can be used and configured, the unit must first be initialised. This can be achieved by connecting directly to the unit
via a web browser or using the VDP Config Tool in the Dahua Toolbox.

To initialise via the web browser, open Internet Explorer and type http://192.168.1.110 then follow the on screen prompts.

Please note: The computer IP address must be in the same IP subnet.

To initialise via the VDP Tool, first download the Dahua Toolbox application and the VDP Tool.

Go to www.dahuasecurity.com, the toolbox application can be found using the top menu.

Go to Support > Download Center > Tools > Maintenance Tools.

Once the Toolbox application has been installed and opened, a list of smaller applications will be listed. Click install next to VDP Tool,
once the installation is complete, click Open to run the program.

With the VDP Tool open and the computer connected to the same network as the VTO, click the refresh icon at the top of the tool.
Any VDP devices connected to the computer directly or via a switch should now be displayed.

3
1. Check the box next to the VTO to be initialised. 2. Click the initialise button to start the initialise process.

3. Enter the new password to be used for the VTO 4. Check or Uncheck Online update options. A direct
and an email address for password recovery. Set internet connection is required for these features.
P/N to P and click next to continue.

5. After a few seconds the tool should show that the 6. The VTO will now show in the Config Tool in an
VTO was successfully initialised. Click Finish to end initialised state. It is now possible to program the
the process. VTO IP address and other settings. You must ensure
the password is modified to the initialised password
of the VTO within the search setting, located at the
top of the config tool.

4 Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
HOME SYSTEM CONFIGURATION
VTO Camera Configuration
Login to the VTO via the computers web browser using the username of “admin” and the password entered during the initialisation
stage.

Once logged in to the VTO, Go to Local Setting

Change Device Type to Villa Station

Click Confirm to save the setting.

5
VTH Monitor Configuration
Before configuring the VTH it must first be initialised. Follow the on screen wizard to set an admin password. The password can only
be made up of numbers.

To configure the VTH unit use the built in menu within the monitor itself. VTH units do not support web browser configuration.

Hold down the Settings button for 5 seconds and enter the admin password set during the initialisation wizard.

If the settings button is only pressed and not held, entering the password 123456 will enter the user settings rather than engineer
settings.

In the settings menu select Network to configure the VTH network settings. When configuring the network address of the VTH it is vital
to ensure the IP address range is within the same Subnet as the VTO.

6 Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
The VTH Config menu is used to set the room number of the VTH and to configure the unit as a Master or Extension unit. If only a single
VTH is being used in the system, then this should be set to Master and a room number chosen. Adding extension VTH units is covered
on page 9. Note: Master monitor must have #0 after the room number.

In the settings menu select SIP to configure the VTH SIP settings. Enter the IP address of the VTO and also a register password of your
choosing, it is important to remember this password as it will be used again later.

For both the VTO and VTH to communicate, each unit must have the IP address details of the other unit. To add the VTO unit to the
VTH, select VTO Config and input the VTO units IP address, Username & Password then set Enable Status to ON.

Set Enable Status to ON and tap OK

7
To add the VTH to the VTO, revisit the VTO web browser and go to Household Setting > Room No Management. Click Clear to
remove the rooms already added into the system by default.

Click Add and enter the connection details for the VTH monitor such as Resident name and the register password chosen earlier.
Please refer to page 6.

Click Save

At the top of the VTH screen the icon should disappear, this indicates that the VTO and VTH are now connected.

If the icon is still displayed, go back to the VTH menu > VTO Config and Disable then re-enable the Status option.

To call the VTH from the VTO, press the button on the VTO unit and press Answer to initiate two way communication.

8 Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
Adding Extension VTH Units
Additional VTH monitors can be added to the system as Extension monitors. These monitors can then be called simultaneously along
with the Master monitor. Up to 9 extension monitors can be added to each master monitor.

To enable this feature and configure the additional VTH units;

Login to the VTO web browser and go to Local Setting > Basic and tick the Group Call option.

Click Confirm to save the setting

On the additional VTH unit, first configure the network address within the same range as both the VTO and existing VTH units.

Go to Settings > VTH Config and select Master, this will change the VTH to Extension mode. Input the room number of the master unit
followed by #1, as an example if the room number is 1 enter 1#1 or 1#2, 1#3 etc. for further additional units.

Note: When using Extension monitors, the Master monitor room number must have #0 included. For example 1#0

In the Master IP field enter the IP address of the main VTH unit.

The master name must be admin and the master password must be the engineer password of the master monitor.

Select OK to save the setting, the configuration is now complete.

9
APPLICATION SET UP
Currently P2P is only supported for iOS and Android devices.
Download the mobile application to your mobile device by scanning the QR codes below or by searching for the app in your relative
app store.

iPhone iPad Android Phone Android Tablet

iDMSS - Free iDMSS HD- Free gDMSS - Free gDMSS HD - Free

Connect using the app


3. Tap the Device List
1. Open DMSS app. 2. Select Home icon.

6. Scan the QR Code for the


4. Tap + 5. Select SN/Scan. VTO in the Network Setting
page of the web browser

10 Tel: +44 (0)1457 874 999 | Fax: +44 (0)1457 829 201 | Email: [email protected] | Online: www.cop-eu.com
7. Confirm the serial
number presented on 9. Enter a name for the
screen matches the serial device and password,
number of the VTO and 8. Select VTO from the list click the Save icon
click Next of Device types

Configure Push Notifications


10. Tap Live preview to 1. Select Message icon 2. Select Notification icon
view the camera stream

3. Enable Subscribe for 4. VTO Events will now be


the device. pushed to the app

11
COP UK, Delph New Road, Dobcross, OL3 5BG England