Dentstore Eng Catalog Inno
Dentstore Eng Catalog Inno
Implant Solution
Help your daily practice superior V e r . 25
industry with the fusion technology to its E.rhBMP-2 developed for the first time in the world.
1994 Developed Korea’s First Dental Implant (BIOPLANT™) and localized it for the First Time in Korea 2010 Obtained MFDS Manufacturing & Sales Approval for COWELL® BMP and Held Korea’s First BMP
Symposium in Seoul, Korea
1998 Founded Asrahi Medical 2011 Obtained US Patent for E.rhBMP-2 Coated Implant
1999 Established R&D Corporation with PNU’s Oral and Biotechnology Research Center 2012 Obtained MFDS Approval for E.rhBMP-2 Spinal Fusion Clinical Test Plan and Launched
INNO SLA Implant System™
2000 Converted to Cowellmedi Corporation (Cowellmedi Co., Ltd.) and Obtained ISO9001 Certificate 2013 Obtained US FDA Approval for INNO SLA Implant System™
2002 Developed ASD Surface Treatment Technology for Dental Implant and Applied for the First Time in Korea 2014 Established a R&D and Education Organization, REID (Research & Education in Implant Dentistry)
2003 Obtained US-FDA Approval for BIOPLANT™ Implant System 2015 Applied SLA-SH® Surface Treatment on INNO SLA Implant System™ → INNO SLA-SH® Implant System
(*SLA-SH® Surface Treatment : the world's superhydrophilic surface made by
Dry Process using Nano/CaP soaking technology after over 20 years’ research and test.
2004 Medaled for Contribution of Developing Korea’s First Dental Implant(BIOPLANT™) from Korea Government
For the details, refer to the page 14 to 19)
2005 Obtained GMP, ISO13485 Certificate, US FDA Approval for ATLAS Implant System™ and CE(EC) Certificate Established a Subsidiary in China (Cowellmedi China) and Establish a Training Course,
2016
ACID(Advance Course in Implant Dentistry) with MMS (Miami Medical Seminars)
2006 Established Subsidiaries in USA (Cowellmedi USA) & Taiwan (Cowell Biotech) and Cowellmedi Tissue
Engineering Institute for Growth Factors 2017 Developed Collagen based Bone graft Materials and Launched Sonator™ 80’s System
2007 Obtained a Patent for E.rhBMP-2 Coated Dental Implant in Korea 2018 Launched InnoGenic™ Ti-Plast and InnoGenic™ PTFE-Plast
2009 Obtained MFDS Approval for Clinical Test of E.rhBMP-2 (COWELL® BMP)
The REID, standing for Research and Education in Implant Dentistry, is a global R&D and Education
institute in the field of Implant Dentistry. Mission
The REID has been dedicated to researching technology and knowledge to find what is the most
appropriate concept of the dental implant treatments and products for clinicians and to apply those To improve how the world dental community treats implant dentistry by providing dental
in their daily practice as well as for patients who require dental implant treatment as its first objective professionals with well-established treatment concepts and comprehensive quality research
of the establishment. as well as internationally multidisciplinary education service for the benefits of patients.
As its second objective of the establishment, the REID also has been committed to training dental
professionals with world-class clinicians, trainers and education curricula.
The REID is looking forward to fully exploring how best its goals may be achieved and may help
implant dentistry better today.
Vision
• Constructing the future of implant dentistry and related fields
• The world-class education provider and research institute
• Sharing more know-hows to have better ideas by expending worldwide network of members
• Providing training system accessible to any dental professional across the globe using such ways
as webinar and online live surgery
Precise machining process using state of the art Computer Numerical Control System fused to COWELL® Class Cleansing process by ultrasonic wave using the 3rd stilled water, vacuum dry and heating dry sterilization enable
1/1000, operated by world-class technical unit ultimately sterilized products and no residues are left on products
SLA-SH® Surface treatment with Biologically active materials to achieve the ideal Osseointegration Sanitarily packed products at Class 10,000 clean room are sterilized by gamma-ray using radiation isotope
Absolutely accurate test and quality control system with cutting edge equipment such as optical profiling measurer, Finished products are sorted and stored in warehouse for immediate delivery
stereoscopic microscope, micrometer scope and other specialized devices for dental implant manufacturing
COWELL WARRANTY ®
PACKAGE SYSTEM
* For more details, visit our website at www.cowellmedi.com 1. Color Classification (Coding) by Fixture Type and External Label Marking
A. Color classication by fixture type
Submerged Submerged Internal External Submerged Mini Cement Mini Ball
Fixture type (Sub.) Short (Sub-S) (Int.) (Ext.) Narrow (Sub-N.) (1P-C.) (1P-B.)
1. Guarantee beneficiary and scope
6) In case implants are transplanted onto patients who sustain or are infected with cell issue contamination;
7) In case other materials from other companies are mix used with Implants, prosthetic parts and instruments Internal (Int.) - - - - -
of Cowellmedi;
8) In case the result of investigation by Cowell R&D Institute, Div. of QA and QC shows the issue is not related External (Ext.) - - - - -
to the products manufactured and provided by Cowellmedi Co., Ltd.
9) In case the information hereby requested, especially, product Lot. No., Serial No. or X-ray photos, is missing. Submerged - - - - - - - - -
Narrow (Sub-N.)
10) In case that the concerned products are not returned.
11) In case the product is damaged due to negligence of handling; and Mini Cement (1P-C.) - - - - - - - -
12) In case the product is opened and fails to remain sterilized
13) In case that the expiry date of the concerned product (not opened products only) is not longer than 1/4. Mini Ball (1P-B.) - - - - - - - -
2. Fixture User Guide (Embedded in the packaging) 3. Fixture packaging opening and the sequence of the product extraction
1. Device Description anatomical landmarks, occlusal conditions, periodontal status, and adequacy of
The Cowellmedi implant system includes a variety of precision-machined fixtures bone. Lateral cephalometric radiographs, CT scans, and tomograms may also be Cover Screw Cover Screw
manufactured from titanium. These implants are surgically inserted into a mandible beneficial. Adequate radiographs, direct palpation, and visual inspection of the
Middle Middle
(the lower jawbone) or a maxillary bone (the upper jawbone) and serve as a fixture site are necessary prior to treatment, planning, and use of Cowellmedi
replacement for patient's tooth root providing a stable foundation for restoration. fixtures.
partially or full edentulous jaws. poor patient oral hygiene or cooperation, patient discomfort, fixture mobility, local
soft tissue degeneration, and unfavorable fixture placement or alignment are some
No-Mount Pre-Mount
3. Directions for use potential causes for loss of anchorage.
1) Surgery - The first stage
lower lower
a. According to the patient's condition, appropriate dental cleaning operations may 8. Surgical complications
be performed and preventive antibiotics may be administered prior to implant The implant procedure has risk, including localized swelling, dehiscence,
operation. tenderness of short duration, edema, hematoma, or bleeding. Numbness of the
b. Clean and disinfect the operative site, administer local anesthesia in the area lower lip and chin region following lower jaw surgery, and of the tissue beside the
and expose the alveolar bone by making appropriate incisions and reflecting the nose followingupper jaw surgery, is a possible side-effect of the surgery. Though it
gingival tissues along the alveolar crest in the area from where teeth were would most probably be of a temporary nature, in very rare cases, the numbness
extracted. has been permanent. Gingival-mucosal (gum tissue) ulceration, tissue reaction, or
c. Drill into the gum in order to implant a fixture into the planed place with infection may occur, but generally responds to local care.
various dental operation tools. The speed of revolution of the drill should be
adjusted by the condition of the bone and the kinds of operation tools. Saline
solution should be poured onto the area so that necrosis doesn't occur by heating
9. How to manage after implanting the Product
a. The upper jaw requires a healing period of 6~8 months depending on the bone Taking out the Ampule
of the bone. (The speed for all drilling should be less then 1200rpm.) quality and the lower jaw requires a healing period of 3~5months depending on
d. Remove the external sterile package cover sheet : open the cap of the ampule; the bone quality. If pressures such as mastication would be applied to the fixture
affix the Fixture driver (in case of No-mount Fixture) or the Mount driver (in case during the healing period, early fixation may not be obtained or osseointegration
of Pre-mount Fixture) to the Hand-piece and connect it to the fixture : move the may not occur for the fixture within the healing period.
assembled piece to the osteotomy site for the implant using care to prevent the b. Once the operator clinically determines that sufficient osseointegration has been
assembled piece from being separated or contaminated with foreign materials. achieved, he/she should begin the stages to produce the dental prosthesis.
e. A fixture is implanted into the bone as planed depth by turning (25~30rpm) a c. The Lot number identification tag should be attached to a patient's chart, and
hand-piece clockwise with 15~50N.cm torque. In event that it is hard to insert, X-ray film in order to pursue the product when needs be.
extend width of bone by tap drill or counter sink in order to facilitate better d. The Operator should determine the osseointegration status of the implant
implantation. through X-ray and clinical methods such as percussion and/or reverse torquing.
f. After finishing implantation, the treated part should be sutured by using a hex
driver to connect to the Cover Screw with torque 5N.cm to prevent the intrusion 10. Storage / Sterilization and Handling
of a foreign substance in the fixture.
2) Surgery - The Second stage
a. Store at room temperature and in a dry place.
b. The fixture, fixture mount and cover screw have been cleaned and sterilized
1 To open, press the upper dotted area
and take out the sterilized blister. 2 Remove the moisture-resistant paper on the
back of the blister, and drop the Ampule
a. Incise gingival of upper part of fixture subsequent to bone fusion and remove by radiation (gamma irradiation) and are ready to use. lightly on the palm of a practitioner or
cover screw, tighten up healing abutment and start gingival curing for prosthesis. c. Product packages should be opend just before their use during operation
b. In general, surgery is done by a method that makes prosthesis. and any product beyond the expiration date should not be used. surgical clothes.
d. Only appropriate sterilized surgical tools made specifically for dental implants
4. Contraindication
The operation should be reconsidered when the patient has any of the following
should be used during the operation.
Fixture Separation
conditions. 11. Expiration date
a. patient with oral infection or inflammation. Expiration date of the product is 5 years from manufacturing.
b. In the case of low quality bone which will result in an unstable implant.
c. Patients who have a drinking problem or mental disease or substance or 12. Cleaning & Sterilization
medicine abuse. Cleaning of surgical instruments supplied non-sterile should be performed
d. Internal disease such as hematodyscrasia or diabetes and undernourishment. according to current dental standard practices. Select a suitable method of
e. Any patient who is not suitable for operation. cleaning that removes all visible contamination from the product in sterilized and
distilled water. After cleaning, package the product appropriately and then
5. warnings sterilized by autoclave at the minimum condition of 250°F (121°C/15 min). x
Implant surgery and restoration involves complex dental procedures. For safe and
effective use of Cowellmedi fixtures, it is strongly suggested that specialized 13. Caution
1 2
training be undertaken since the surgical techniques required to place dental a. As this product is sterilized by Gamma radiation, should not be used Hold the Ampule with both hands, twist Fasten in two ways.
implants are highly specialized and complex procedures. Improper patient under any circumstances if is open.
selection and technique can contribute to fixture failure and/or loss of supporting b. Every product is disposable. It should not be reused. it 45 degree, and separate the middle part. 1) No Mount -> Fasten the Fixture driver
bone. Cowellmedi fixtures are intended for use only in the indicated applications. Care should be taken so that the fixture 2) Pre Mount -> Fasten the Mount driver
Dental fixtures must not be altered in any way. The use of electro-surgical
Cowellmedi Co., Ltd. will not fall.
instruments or lasers around metallic fixtures and their abutments is not
recommended due to the risk of electric shock and/or burns. Fixture mobility, bone 48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 617-801, Republic of Korea
loss, or chronic infection may indicate fixture failure. The Treatment should be done Tel. +82-51-312-2027~8 Fax. +82-51-316-2628
in an aseptic condition by an operator who wears an aseptic costume. If the fixture http://www.cowellmedi.com Cover Screw Separation
becomes contaminated by the patient's body fluids in any way, the fixture cannot be D/T
used in any other patient.
Cowellmedi USA INC. 8507 N. 51st Avenue Glendale, Arizona 85302 U.S.A
Tel. +1-623-939-1344 Fax. +1-623-939-1472
6. precautions
The surgical techniques required to place endosseous dental fixtures require EC-REPRESENTATIVE
specialized and complex procedures. Formal training for placement of fixtures is MT Promedt Consulting GmbH Altenhofstrasse 80,D-66386 St. Ingbert, GERMANY
recommended.
Important : Determine local anatomy and suitability of the available bone for fixture
placement. Thorough screening of prospective fixture candidates must be Do Not Room Attention, See Gamma
Reuse Temperature Instructions for Use Sterilized
performed. Visual inspection as well as panoramic and periapical radiographs
areessential to determine 2013.12.23 / CWM-I-014 (Ver.3)
1 Separate the upper part of the Ampule. 2 Fasten the Hex Driver to the Cover Screw
completely. Care must be taken to prevent
patient partient from swallowing the Cover
Screw at the time of placing
Cemented Abutment
PRODUCT : Dental Implant
TYPE : 2SCN4525
SIZE : Ø4.5X5.5mm C:2 (Sub. N-Hex)
REGISTRATION NO. : 05-189
LOT NO. : 16G2A030
DATE OF MANUFACTURE : 2016.07.04
USE BY : Not Applicable (N/A)
PACKING UNIT : 1 SET
STORAGE CONDITION : Store at room temperature and in a dry place.
Do Not Attention, See 30˚C
Reuse the Manual 1˚C
INSTRUCTION : Refer to manual MEDICAL DEVICE
CAUTION : Please discard the product when package is damaged.
Cowellmedi Co.,Ltd. :
48, Hakgam-daero 221beon-gil, Sasang-gu, Busan, 617-801, Republic of Korea
TEL. +82-51-312-2027~8 http://www.cowellmedi.com / LICENSE NO. : 780
D/T : Cowellmedi USA INC. / 8507 N. 51st Avenue Glendale, Arizona 85302 U.S.A
TEL. 1-623-939-1344 FAX. 1-623-939-1472
EC-REPRESENTATIVE : MT Promedt Consulting GmbH / Altenhofstrasse 80,
D-66386 St. Ingbert, Germany
Cowellmedi Co.,Ltd.
2SCN4525 - 16G2A030
(01) 08809471721146
(11) 160704
The Pioneers in Dental Implant & E.rhBMP-2 (10) 16G2A
(21) 030
CWM-L-005(Ver.3)
Cowellmedi Co.,Ltd.
KCA010F - 16G5A016
(01) 08809471726493
(11) 160727
(10) 16G5A
(21) 016
CWM-L-006(Ver.3)
Experience the superiority > Sandblasted with Biocompatible grits unlike Majority of implants in market are done with Alumina
> Macro-pore & Micro-pore of Ti-Oxide layer mimicking the etched enamel rod of tooth
> Even distribution of roughness through the whole portion of Implant Surface
of SLA-SH ® surface > No destruction or alternation of the surface are caused even with torque force at 120 N.cm
> Acceleration of Osseointegration and Maximization of BIC
> SLA-SH® is applied for All of the COWELL® Implant Systems
A B
C SLA-SH®
Superhydrophilicity, Uniform micro-surface geometry, > Surface treatment patterns were observed on electron microscope photographs of 5,000 magnifications for top parts of the
implants.
Maximized BIC and Acceleration of ossteointegration
> Sand-blasted surface conditions were observed in the product A, B and Cdue to insufficient acid etching patterns in deep parts as
Aspiring for 100% perfection with SLA-SH® SLA-SH® is sandblasted with Biocompatible grits with even particle size unlike others are done with Alumina.
> The entire surface of the SLA-SH® treated implant showed uniform acid etching patterns. This implies that the
acid etching of the SLA-SH® surface is perfect.
SLA-SH® 015
SLA-SH®
SLA-SH®
2. Evaluation using SSEM (Stereo Scanning Electron Microscope) 3D images 3. The surface activity increased due to the great surface wetness
A. SLA-SH® Surface A. Contact angle measurement evaluation result for the saline solution
Measurement Info
Magnification : 19.93
Measurement Mode : VSI
Sampling : 496.74 nm
After hydrophilicity After superhydrophilicity
Array Size : 640 X 480 After SLA treatment(133.06°)
activation treatment(36°) activation treatment(9°)
After neutralization process and bioactive material coating treatment, the sample became extremely hydrophilic
Surface Stats and the surface energy was increased, which facilitated expedition of osteoblast activation to be fused to the bone faster
Ra : 1.95 ㎛
Rq : 2.52 ㎛
Rt : 19.83 ㎛
Measurement Info
Capillarity in the actual clinical setting, which accelerated the penetration of blood
Magnification : 19.93 ※ Quoted from the website of Cowellmedi Clinical Research Group (www.cowellimplant.com)
Measurement Mode : VSI
Sampling : 496.74 nm Blood Friendly
Array Size : 640 X 480
A B C SLA-SH®
After SLA treatment (Ra: 1.78㎛) After hydrophilicity activation treatment (Ra: 1.80㎛)
> There was almost no difference of surface roughness and micro-geometry, and the difference of surface wetness took place
in the same physicochemical properties as surface energy increased by hydrophilicity activation treatment
> Surface wetness was improved by increased surface energy of C1s, O1s and Ti2p after hydrophilicity activation treatment
> To maintain and even to enhance surface wetness, superhydrophilicy activation treatment was carried out and contamination
by carbon in the atmosphere is prevented during packing and sterilization
4. Its safety has been proven through perfect cleaning with an automated system COWELL® CLASS 1/1000
A. Comparison of surface element tests through X-ray diffraction A SUBTLE DIFFERENCE MAKES THE DENTAL IMPLANT OR NOT
" # $ SLA-SH®
1. Fixture Manufacturing Tolerance Evaluation
A1
a. The specimen was fixed in Jig
Method b. Each dimensional difference of 3 inner hexagonal connection sides
> Cutting-edge automated system that produces the 3rd distilled water (Hex-3, Hex-2, Hex-3) of 5 specimens was measured
C4
C2
C1 Used Equipment Measuring Microscope and Jig
A2
B3
C3
Each dimensional difference of 3 inner hexagonal sides should be
Criteria
B. Comparison of surface element tests (X-ray Photo-electron Spectroscopy, XPS) no more than ±0.001mm (1.000༁) from 2.500mm
Unit : % INNO SLA-SH® Submerged Fixture (5 Pieces of ST4510S)
Sample Specimen
C1s O1s Ti2p Si2p N1s #1 #2 #3 #4 #5
B2
B1
" 34.12 45.05 15.11 5.24 0.47 Hex-1 2.499 2.500 2.500 2.500 2.500
# 31.84 46.49 15.22 4.87 1.57 Hex-2 2.499 2.500 2.501 2.500 2.500
A4
A3
$ 32.19 47.58 17.58 2.65 N.D Hex-3 2.500 2.500 2.500 2.501 2.499
SLA-SH® 27.19 50.81 17.61 N.D N.D Average 2.500 2.500 2.500 2.500 2.500
Total Average 2.500
Result (Pass/Fail) Pass
> Quantitative analysis of each surface element found 30% carbon, 47% oxygen, 16% titanium, and 4% silicon in all products.
Manufacturing No more than
> For SLA-SH®, they only consisted of carbons(C1s), oxygen(O1s), and titanium(Ti2p). Tolerance ±0.001mm (1.000༁)
B4
> Sodium hydroxide, the main element of the alkali washing solution, combined with silicon(Si) to form water-soluble
Na2SiO2(OH)2·4H2O(water glass), which removed the other elements.
2. Prosthetic Component Manufacturing Tolerance Evaluation
A1
Unit : ppm Method b. Each dimensional difference of 3 outer hexagonal connection
Sample F- Cl- NO2- SO42- Br- NO3- PO43- sides (Hex-3, Hex-2, Hex-3) of 5 specimens was measured
" N.D 0.024 0.027 0.002 N.D 0.031 N.D Used Equipment Micro-Measuring Instrument
# N.D 0.027 0.019 0.002 N.D 0.030 N.D C
Each dimensional difference of 3 outer hexagonal connection sides should be
C3
Criteria C2
$ C2
no more than ±0.001mm (1.000༁) from 2.490mm
A2
N.D 0.071 0.020 N.D N.D 0.023 N.D C1 C1
B3
C3
A2
INNO SLA-SH® Sub. Cemented Abutment (5 Pieces of 2SCH4515)
Specimen
A3
> Similar ions were detected in all the products, but they are not harmful to human because their elements and quantities #1 #2 #3 #4 #5
A4
Hex-1 2.489 2.490 2.490 2.490 2.490
B2
do not affect the human body and those have been proven in many studies.
B1
Hex-2 2.490 2.490 2.490 2.490 2.490
B1
> For SLA-SH®, no other elements except for NO3- were detected. Alkali washing completely removed the SO42- and
Hex-3 2.490 2.490 2.490 2.490 2.491
B2 B4
Cl- ions of sulfuric acid and hydrochloric acid, which are used for heated acid etching because they form water-soluble salts
A3
Average 2.490 2.490 2.490 2.490 2.490
of Na2SO4 and NaCl.
Total Average 2.490
> No elements that interfere with osteo anagenesis were found from both the surface and elution elements, which showed Pass
Result (Pass/Fail)
that the cleansing process was perfectly carried out.
C1
Manufacturing No more than
C2
Tolerance ±0.001mm (1.000༁)
B4
COWELL IMPLANT SYSTEM ®
Easy Tmporary Abutment
Temporary restoration for
Miniplus®
For mandible anterior spaces and edentulous arch.
Semi-permanent or temporary solution for anterior Sonator 80’s
spaces with extremely narrow ridge.
Allows you to treat your patients
with minimum standard of care
of an implant supported overdenture
INNO™ External Fixture
at affordable cost with great satisfaction.
Stable engraftment of periosteum
INNO™ Submerged Fixture in the boundary surface
INNO Fit® Hybrid Ti-Base & Block
of bone and implant.
Designed for all clinical cases including INNO™ Internal Fixture Digital integrated prosthetic solution coming
immediate implant placement, immediate loading,
One stage restoration with state with a variety of types and dimensions
implant depth adjustment, maxillary sinus and etc.
of the art design. 4 spiral round cutting that optimize predictable results.
Simply doing more for your implant treatment. Cemented Abutment
edges maximize the efficiency of
self tapping with a sharp edge and Cutting surface is
accommodates bone chips as ideal designed for anti-rotation
cutting edge pocket space. of prosthesis.
INNO SLA-SH® Implant System
INNO SLA-SH® Implant System
Fixture type Submerged (Sub.) Submerged Short (Sub-S) Internal (Int.) External (Ext.) Submerged Narrow (Sub-N.)
Platform Neck
Simpler, Speedier and Safer Surgical Kit
Sub. / Sub-N. / Int. / Ext. / Provides different types of exclusive kits, respectively
> Stable engraftment of periosteum in the boundary
Wide and deep upper thread surface of bone and implant.
> Prevents the compressive necrosis of the > Prevents possible infections around the implant.
cortical bone.
Sub. KSA002 Sub. KCA010F Sub-S. KSI001
> Minimizes the need for countersink drills.
> Reinforces mechanical strength by reinforcing
thickness. Open Thread Path
Parallel Pin
Point Ø2.2x7 7 7 7 7 7
Ø2.2x8 8 8 8 8 8
Final Drill
1.2 Hex Driver
10 10 10 10 10
drilling.
Ø2.2x10
Machine Ratchet
Counter sink
Drill Extension
Spare
Machine Long Ratchet Long
pocket space.
Path Point Ø2.2x7 7 7 7 7 7 Parallel Pin
Parallel Pin
Ø2.2x8 8 8 8 8 8
Ø2.2x8 8 8 8 8 8
Final Drill
1.2 Hex Driver
Final Drill
1.2 Hex Driver
Ø2.2x10 10 10 10 10 10
Ø2.2x10 10 10 10 10 10
Mount Driver
Mount Driver
Ø2.2x12 12 12 12 12 12
Ø2.2x12 12 12 12 12 12
Machine Ratchet
Machine Ratchet
Fixture Driver Ø2.2x14 14 14 14 14 Spare
Fixture Driver Ø2.2x14 14 14 14 14 spare
Counter sink
Counter sink
Machine Short Ratchet Long Drill Extension
Machine Short Ratchet Short Drill Extension Hex 2.7 Hex 2.7
Spare
Spare
Machine Short Ratchet Long
Hex 3.4 Hex 3.4 Multi Countersink
Machine Long Ratchet Long
* Two Piece Screw-Cement Retained & Cement Retained Abutment * Two & One Piece Overdenture Retained Abutment
Submerged & Submerged Short : Cemented | Angulated | Milling | Meta G UCLA | Plastic UCLA Submerged & Submerged Short : Sonator S | Sonator A | Ball
Hybrid S | Hybrid L | Hybrid A Ti-Block
Internal : Sonator S | Ball
Submerged Narrow : Cemented | Angulated | Temporary | Meta G UCLA | Hybrid S | Hybrid L
External : Ball
Internal : Cemented | Angulated | Meta G UCLA
External : Cemented | Angulated | Temporary | Meta G UCLA | Plastic Sleeve
Indirect Impression Technique
(No Abutment Modification applied) Multi Pick-up Sonator Impression
Ø4.5 Abutment Ø5.5 Abutment Ø6.5 Abutment Impression Coping Multi Transfer Post Coping
(with Open Tray)
Pick up (Open Tray)
Pouring stone Cast model with Adapting Plastic Wax build-up Final restoration Try-in Final
for cast model gum coping on Lab on Abutment restoration
or into tray Analog with fixture
Hex
FixtureLevel
Procedure I
Hybrid S Ø4.0 Hybrid S Ø5.0/6.0 Hybrid L Ø4.0 Hybrid L Ø5.0/6.0 Hybrid Ti-Block Scanbody
Impression
Prosthetic
034p 034p 035p 035p 035p 036p 036p 036p 037p 037p
039p 040p 040p 040p 040p 041p 041p 041p 041p 042p
039p 039p
Procedure II
Prosthetic
Multi Multi Multi Multi Impression Multi Multi Multi Meta G Multi Plastic Multi Titanium Polishing
Multi S Multi A Protection Cap Scanbody Hybrid Ti-Base Coping Transfer Post Lab Analog ULCA Cylinder UCLA Cylinder Cylinder Protector
Hex 2.5
044p 044p 044p 044p 045p 045p 045p
044p
Procedure III
Prosthetic
Length Lock Lock Look Look Lock Pick-up Lock Lock Lock Titanium
7 / 8 / 10 Protection Cap Scanbody Hybrid Ti-Base Impression Coping Lab Analog CCM Cylinder Cylinder
12 / 14mm
Diameter
Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0
Abutment Level
Absolute Protection Cap Impression Cap Lab Analog Plastic Coping
Impression
048p
Procedure V
Prosthetic
Direct
Impression
Straight
Sonator
Impression Sonator
Sonator S Sonator A Coping Analog
054p 054p
Procedure VII
Prosthetic
Ball
Ball Analog
Submerged Implant
Submerged Implant No-Mount > Packing Unit : 1 Fixture + 1 Cover Screw
Diameter
Ø3.5
Length
Submerged Fixture
SUB.
HEXAGON Surface Treatment : SLA-SH® 7 -
Hex
7 ST4007SM
8 ST4008SM 7 8 10 12 14
10 ST4010SM L
12 ST4012SM
14 ST4014SM
D
Diameter
Ø4.5
Length
L 7 ST4507SM
8 ST4508SM 7 8 10 12 14
L
10 ST4510SM
12 ST4512SM
14 ST4514SM D
Diameter
Ø5.0
D Length
7 ST5007SM
8 ST5008SM
INNO Fixture Code L
7 8 10 12 14
10 ST5010SM
S T 40 10 S M Ex.) 12 ST5012SM
Type body Diameter Length Surface Treatment Mount SLA No-Mount ST4010SM 14 ST5014SM D
Submerged Taper Ø4.0 10mm SLA No-Mount
Diameter
Ø6.0
S T 40 10 S Ex.) Length
Type body Diameter Length Surface Treatment Mount SLA Pre-Mount ST4010S
Submerged Taper Ø4.0 10mm SLA Pre-Mount 7 ST6007SM
7 8 10 12
8 ST6008SM L
10 ST6010SM
12 ST6012SM
D
14 -
Submerged Implant
Pre-Mount > Packing Unit : 1 Fixture + 1 Cover Screw + 1 Mount Fixture Mount
Length 5.4
L
Diameter
Ø3.5 2SMHR001
Length
8 10 12 14 > Packing Unit : 1 Mount + 1 Mount Screw
> Tightened with 1.2 Hex Driver
7 - > Tightening Torque Force : 5~10 N.cm
Hex
8 ST3508S
L
10 ST3510S
12 ST3512S
14 ST3514S D
*&YUSB1SPEVDU
Diameter
Ø4.0 Cover Screw
Length Length 3 4.2 5.2
7 8 10 12 14 L 2SCS000 2SCS001 2SCS002
7 ST4007S
> Packing Unit : 1 Cover Screw
8 ST4008S > To Seal the Conical Interface of Fixture
10 ST4010S L > Longer Cover Screw for Deeply Inserted Fixture
> Tightened with 1.2 Hex Driver
12 ST4012S >Tightening Torque Force : 5~10 N.cm
14 ST4014S
D
Diameter
Ø4.5
Length
7 8 10 12 14
7 ST4507S
Healing Abutment
8 ST4508S D
L
10 ST4510S Diameter Ø4.5 Ø5.5 Ø6.5
L
C Length
1 2 2 2
12 ST4512S Cuff 1 1
14 ST4514S D 1 2HS4511 2HS5511 2HS6511
2 2HS4522 2HS5522 2HS6522
3 2HS4532 2HS5532 2HS6532
Diameter
Ø5.0 4 2HS4542 2HS5542 2HS6542
Length
7 8 10 12 14 5 2HS4552 2HS5552 2HS6552
8 ST5008S
L Diameter Ø7.5 Ø8.5 Ø9.5
10 ST5010S
Length
Cuff 2 2 2
12 ST5012S
3 2HS7532 2HS8532 2HS9532
14 ST5014S D
> Packing Unit : 1 Abutment
> For Remodeling Gingival Contour during Soft Tissue Healing
Diameter > Select according to Gingival Height and Abutment Type
Ø6.0 > Tightened with 1.2 Hex Driver
Length
7 8 10 12
> Tightening Torque Force : 5~10 N.cm
7 ST6007S
8 ST6008S L
10 ST6010S
12 ST6012S
D
14 -
Submerged Implant
Hybrid S Ti-Base
Prosthetic Procedure I D
L
1.2 Hex. Type Hex
Components Selection Guide for Ti-Base & Block, Cemented and UCLA Abutment 2.15
Diameter Ø4.0 Ø5.0 Ø6.0
C Length
Cuff 3.75 3.75 3.75
2.45 2.15
0.8 2SLH404 2SLH504 2SLH604
Hybrid L Ti-Base
(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
D
(Hex) (Hex) (Hex) (N-Hex) Cemented Angulated Milling
Abutment Abutment Abutment Type Hex
Hybrid S Ti-Base Hybrid L Ti-Base Hybrid Ti-Block L 1.2 Hex.
Diameter Ø4.0 Ø5.0 Ø6.0
C 2.15 Length
Cuff 5.5 5.5 5.5
1 2SLH415 2SLH515 2SLH615
Ø4.0 Ø5.0 Ø6.0 2 2SLH425 2SLH525 2SLH625
(Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex)
3 2SLH435 2SLH535 2SLH635
Easy Temporary Temporary Meta G UCLA Plastic UCLA
Abutment Abutment Abutment Abutment > Packing Unit : 1 Ti-Base + 1 Abutment Screw > Library available for EXOCAD®, 3Shape®,
> For Screw-Cement or Screw Retained Abutment Dental Wings® and Others
> Titanium Base for Strength of CAD/CAM > Connected with Abutment Screw (2SSHR200)
Customized Zirconium Abutment or Crown > Tightened with 1.2 Hex Driver and Torque Wrench
> Gold Color for More Translucent Restoration > Tightening Torque Force : 30 N.cm
> Cutting Surface (Ø4.0) and Humped Design (Ø5.0, Ø6.0) > Use Scanbody for 3D Work
for Anti-Rotation of Prosthesis > Fixture Level Impression
Model Scanning Method
(Hex)
Scanbody Replica
Hybrid Ti-Block
D D
1.2 Hex.
> Packing Unit : 1 Ti-Block + 2 Abutment Screws > Connected with Abutment Screw (2SSHR100)
Hex N-Hex > For Screw-Cement or Screw Retained Abutment > Tightened with 1.2 Hex Driver and Torque Wrench
> Block Abutment for CAD/CAM Customized Abutment > Tightening Torque Force : 30 N.cm
> Library available for EXOCAD®, 3Shape®, > Use Scanbody for 3D Work
(Hex) (N-Hex) (Hex) (N-Hex) Dental Wings® and Others > Fixture Level Impression
Pick-up Impression Coping Transfer Post
Scanbody
D
Intra-oral Scanning Method Open or Closed Tray Impression Diameter Ø4.3
1.2 Hex.
Length
Cuff 8
L 2.45
2 2SSB4329
Healing
Fixture Cover Screw Abutment
Submerged Implant
Cemented Abutment Milling Abutment
Type Hex D
D 1.2 Type Hex N-Hex
1.2 Diameter Ø4.5 Ø5.5 Ø6.5
L Diameter Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
L
Length
Cuff 4 5.5 7 4 5.5 7 4 5.5 7 Length
C Cuff 7 7 7 7 7 7
C 1 2SCH4514 2SCH4515 2SCH4517 2SCH5514 2SCH5515 2SCH5517 2SCH6514 2SCH6515 2SCH6517
2 2SMH4527 2SMH5527 2SMH6527 2SMN4527 2SMN5527 2SMN6527
2 2SCH4524 2SCH4525 2SCH4527 2SCH5524 2SCH5525 2SCH5527 2SCH6524 2SCH6525 2SCH6527
* "CVUNFOU4DSFX Hex N-Hex 4 2SMH4547 2SMH5547 2SMH6547 2SMN4547 2SMN5547 2SMN6547
3 2SCH4534 2SCH4535 2SCH4537 2SCH5534 2SCH5535 2SCH5537 2SCH6534 2SCH6535 2SCH6537
2SSHR200
> Packing Unit : 1 Abutment + 1 Abutment Screw
Hex N-Hex 4 2SCH4544 2SCH4545 2SCH4547 2SCH5544 2SCH5545 2SCH5547 2SCH6544 2SCH6545 2SCH6547
> For Screw-Cement or Cement Retained Prosthesis
5 2SCH4554 2SCH4555 2SCH4557 2SCH5554 2SCH5555 2SCH5557 2SCH6554 2SCH6555 2SCH6557 > Block Abutment for Customized Contouring
> Gold Color for More Translucent Restoration (Hex) and Classification with N-Hex
> Connected with Abutment Screw (2SSHR100)
Type N-Hex
> Tightened with 1.2 Hex Driver and Torque Wrench
Diameter Ø4.5 Ø5.5 Ø6.5 > Tightening Torque Force : 30 N.cm
Length > Fixture Level Impression
Cuff 4 5.5 7 4 5.5 7 4 5.5 7
1 2SCN4514 2SCN4515 2SCN4517 2SCN5514 2SCN5515 2SCN5517 2SCN6514 2SCN6515 2SCN6517
2 2SCN4524 2SCN4525 2SCN4527 2SCN5524 2SCN5525 2SCN5527 2SCN6524 2SCN6525 2SCN6527
3 2SCN4534 2SCN4535 2SCN4537 2SCN5534 2SCN5535 2SCN5537 2SCN6534 2SCN6535 2SCN6537
4 2SCN4544 2SCN4545 2SCN4547 2SCN5544 2SCN5545 2SCN5547 2SCN6544 2SCN6545 2SCN6547
5 2SCN4554 2SCN4555 2SCN4557 2SCN5554 2SCN5555 2SCN5557 2SCN6554 2SCN6555 2SCN6557 Easy Temporary Abutment
> Packing Unit : 1 Abutment + 1 Abutment Screw D
Submerged Implant
Meta G UCLA Abutment Pick-up Impression Coping
D Type Hex N-Hex
D
Diameter Ø4.5 Ø4.5 Type Hex N-Hex
1.2 Length Diameter
Cuff 12 12 Length Ø4.5 Ø5.5 Ø6.5 Ø4.5 Ø5.5 Ø6.5
L
1 2SGH45N 2SGN45N 16 (Short) 2SIH45S 2SIH55S 2SIH65S 2SIN45S 2SIN55S 2SIN65S
L
2 2SGH452N 2SGN452N 20 (Long) 2SIH45L 2SIH55L 2SIH65L 2SIN45L 2SIN55L 2SIN65L
C 2 Pieces
3 2SGH453N 2SGN453N > Packing Unit : 1 Pick-up Impression Coping + 1 Guide Pin
Hex N-Hex > For Open Tray Impression
> Packing Unit : 1 Abutment + 1 Abutment Screw > Connected with Guide Pin
> For Screw-Cement or Screw Retained Prosthesis (Short) (Long) (Short) (Long) > Tightened with 1.2 Hex Driver and Torque Wrench
> Modification to Angulated Abutment, Customized Abutment and Telescopic Abutment Hex N-Hex
> CCM Alloy Core for Precise Connection
> Cast with Non-Previous Metal or Gold Alloy
> Connected with Abutment Screw (2SSHR100)
> Tightened with 1.2 Hex Driver and Torque Wrench
> Tightening Torque Force : 30 N.cm
> Fixture Level Impression
Transfer Post
Plastic UCLA Abutment D
> Packing Unit : 1 Abutment + 1 Abutment Screw 15 (Long) 2STH45L 2STH55L 2STH65L 2STN45L 2STN55L 2STN65L
(Short) (Long) (Short) (Long)
Hex N-Hex > Same Purpose of Use as Meta G UCLA Abutment but Low Accuracy of Connection Hex N-Hex > Packing Unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid Type)
> PMMA Material
2 Pieces 1 Piece > For Closed Tray Impression
> Connected with Abutment Screw (2SSHR100)
> Connected with Guide Pin
> Tightened with 1.2 Hex Driver and Torque Wrench
> Tightened with 1.2 Hex Driver and Torque Wrench
> Tightening Torque Force : Finger Light Force during Wax Pattern Fabrication, 30 N.cm after casting
> Fixture Level Impression
Abutment Screw
Diameter
1.2 Hex. 1.2 Hex. Length 2.45 2.15
8.5 2SSHR100 2SSHR200
2.45 2.15
> Packing Unit : 1 Abutment Screw
> 2SSHR100: Hybrid Block / Scanbody / Angulated / Milling / Temporary / Meta G UCLA / Plastic UCLA Abutment Guide Pin
L > 2SSHR200: Hybrid S & L Ti-Base / Cemented / Easy Temporary Abutment
> Tightened with 1.2 Hex Driver and Torque Wrench Type
Length Pick-up Impression Coping
L
22.2(Short) 2SISR001SS
26.2(Long) 2SISR001SL
Replica Length 12
Type
L 2SRHR001 Length Transfer Post
> Packing Unit : 1 Replica L 16.3(Short) 2STH001SS
> Mimicking of Conical Interface of Fixture
20.3(Long) 2STH001SL
> Analog of Fixture for Cast Model
Submerged Implant
Prosthetic Procedure II Multi S Abutment Cuff
Diameter
1
Ø4.5
2SMS451
Ø5.5
2SMS551
D
Component Selection Guide for Multi S&A Abutment 2 2SMS452 2SMS552
C
3 2SMS453 2SMS553
1 Piece 4 2SMS454 2SMS554
Polishing Protector 5 2SMS455 2SMS555
(Hex) (N-Hex)
Multi A Abutment Type Hex
Multi Hybrid Ti-Base (Hex) (N-Hex) (Hex) (N-Hex) (Hex) (N-Hex) Diameter(Angle)
D 1.2 Hex.
Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
Multi Meta G Multi Plastic Multi Titanium A
Cuff
UCLA Cylinder UCLA Cylinder Cylinder 2 2SMAH45152
C 3 2SMAH45153 2SMAH45303 2SMAH55153 2SMAH55303
L
4 2SMAH45154 2SMAH45304 2SMAH55154 2SMAH55304
5 2SMAH55155 2SMAH55305
Model Scanning Method
(Hex) (N-Hex)
2 Pieces Type N-Hex
Hex N-Hex
Diameter(Angle)
Multi Scanbody Cuff
Ø4.5(15°) Ø4.5(30°) Ø5.5(15°) Ø5.5(30°)
Lab Analog
2 2SMAN45152
3 2SMAN45153 2SMAN45303 2SMAN55153 2SMAN55303
4 2SMAN45154 2SMAN45304 2SMAN55154 2SMAN55304
5 2SMAN55155 2SMAN55305
Submerged Implant
Multi Scanbody Multi Lab Analog
D
1.2 Hex. Type Hex N-Hex Diameter Ø4.5 Ø5.5
Diameter Ø4.5 Ø4.5 2SMA45 2SMA55
D
2SMB001H 2SMB001N
> Packing Unit : 1 Analog
> Packing Unit : 1 Scanbody + 1 Cylinder Screw > Replacement of Abutment Shape in Cast Model
> For both, Model Scanner and Intra Oral Scanner > Choose by Abutment Size
D
> For Multi Hybrid Ti-Base
Hex N-Hex > Titanium Core for More Strength and Precision
> No Need to Spray
> Connected with Cylinder Screw (2SMCS100)
> Tightened with 1.2 Hex Driver and Torque Wrench Multi Meta G UCLA Cylinder
> Tightening Torque Force : 15~20 N.cm Type Hex N-Hex
Submerged Implant
Polishing Protector
D Diameter Ø4.5 Ø5.5
Holder
KMHS01
(N-Hex)
Lock Scanbody Lock Lab Analog
S Machine Driver
KMMSD21L
S Ratchet Driver
KRMSD15L
Healing
Fixture Cover Screw Abutment
Submerged Implant
Lock Abutment Diameter
Lock Lab Analog Diameter Ø4.5
D Cuff Ø4.5
2SLA45
0.5 2SLA400
1 2SLA410 > Packing Unit : 1 Analog
C
> Replacement of Abutment Shape in Cast Model
2 2SLA420 > Connected with Guide Pin
3 2SLA430 > Tightened with 1.2 Hex Driver and Torque Wrench
4 2SLA440
> Packing Unit : 1 Abutment > Integrated with Screw and Abutment
> For Screw-Retained Prosthesis > Tightened with Lock Ratchet Driver and Torque Wrench
> Titanium Base for Cylinder > Tightening Torque Force : 30 N.cm
> Gold Color for More Translucent Restoration > Abutment Level Impression
Lock CCM Cylinder Diameter Ø4.5
2SLCH45
Lock Protection Cap Diameter Ø4.5 > Packing Unit : 1 Cylinder + 1 Cylinder Screw > Cast with Non-Previous Metal or Gold Alloy
D > For Screw, Cement or Screw-Cement Retained Prosthesis > Connected with Cylinder Screw
2SLP45 > Modification to Various Types of Abutment > Tightened with 1.2 Hex Driver and Torque Wrench
> Packing Unit : 1 Cap > CCM Alloy Core for Precise Connection > Tightening Torque Force : 30 N.cm
> Protection from Cheek and Tongue for Gingival Healing Period
> Gingival Retraction for Prosthodontic Margin of Abutment
Submerged Implant
Prosthetic Procedure IV
Absolute Abutment
Diameter Ø4.5 Ø5.5
D Length
5.5 7 4 5.5 7
Cuff 4
Component Selection Guide for Absolute Abutment L
1 2SAC4514 2SAC4515 2SAC4517 2SAC5514 2SAC5515 2SAC5517
2 2SAC4524 2SAC4525 2SAC4527 2SAC5524 2SAC5525 2SAC5527
C
3 2SAC4534 2SAC4535 2SAC4537 2SAC5534 2SAC5535 2SAC5537
4 2SAC4544 2SAC4545 2SAC4547 2SAC5544 2SAC5545 2SAC5547
5 2SAC4554 2SAC4555 2SAC4557 2SAC5554 2SAC5555 2SAC5557
Diameter Ø6.5
> Packing Unit : 1 Abutment + 1 Production Cap
1.2 Hex Driver > For Cement Retained Prosthesis
(Crown) (Bridge) Length
Cuff 4 5.5 7 > Cutting Surface for Anti-rotation of Prosthesis
Plastic Coping
1 2SAC6514 2SAC6515 2SAC6517 > Integrated with Screw and Abutment
> Tightened with 1.2 Hex Driver and Torque Wrench
2 2SAC6524 2SAC6525 2SAC6527 > Tightening Torque Force : 30 N.cm
3 2SAC6534 2SAC6535 2SAC6537 > Abutment Level Impression
4 2SAC6544 2SAC6545 2SAC6547
5 2SAC6554 2SAC6555 2SAC6557
Lab Analog
Submerged Implant
Prosthetic Procedure V Prosthetic Procedure VI
Component Selection Guide for Straight Abutment Component Selection Guide for Sonator Abutment
Black
Block Out Processing
Outer Cap Spacer male
Straight Abutment
Healing
Fixture Cover Screw Abutment
Straight Abutment
D Diameter Ø3.5 Ø4.5 Analog
Length
Cuff 8 8
7 5.5 L 0.5 2SSCM308 2SSCR408
4
1 2SSCM318 2SSCR418
C
2 2SSCM328 2SSCR428
3 2SSCM338 2SSCR438
4 2SSCM348 2SSCR448 Impression Coping
Shoulder Driver
Diameter Ø4.0
KRR19L
> Packing Unit : 1 Driver
> To Install Straight Abutment
Healing
Fixture Cover Screw Abutment
Submerged Implant
Sonator S Abutment
Black
Block Out Processing
Outer Cap Spacer male
Outer Cap
2.25mm
Code SONOC01
Outer Cap Black Processing male
Ø5.4 > Packing Unit : 2 Outer Caps and 2 Black Processing Male
H-Type Inner Caps > Black Processing Male: Inserted and Removed with I&R Driver
Ø5.4
NH-Type Inner Caps
Red : Orange : Green :
Retention Force Retention Force Retention Force
About 10N About 15N About 22N
> Packing Unit : Sonator A Abutment + Abutment Screw + Carrier + 3 NH-Type Inner Caps + Outer Cap
+ Block-out Spacer + Black Processing Male Sonator Impression Coping
> For Implant Supported Over-denture Prosthesis Length 4.4
> Stable with Low Vertical Height SONIP04
1.2 Hex Driver
Ø4.0 > 6 kinds of Inner Caps give various holding force (Both, H and NH-Type Inner Caps are used for Sonator A Abutment) L
15˚ > Path Compensation up to 35 ° based on 2 Implants > Packing Unit : 4 Impression Copings
> Connected with Abutment Screw (2SSHR330) > Connected over Sonator Abutment after Placing Block-out Spacer
> Carrier : Used for delivery of the abutment > For Close Tray Impression
L
> Tightened with 1.2 Hex Driver and Torque wrench
> Tightening Torque Force : 30 N.cm
> Abutment Level Impression
Sonator Lab Analog
Length 10.2
SONLA04
Submerged Implant
Sonator S Ratchet Driver
L
Diameter
Length Ø3.1 Prosthetic Procedure VII
18 SONRD19L
D Component Selection Guide for Ball Abutment
> Used to Tighten and Untighten Sonator S Abutment
Hex Driver
Type Machine
Socket
L Hex
Length Hex 1.2
22(Short) KMD12S
28(Long) KMD12L
Type Ratchet
Hex
L Length Hex 1.2
15(Short) KHD1215
21(Long) KHD1221 Ball Analog
27(X-Long) KHD1227
Healing
Fixture Cover Screw Abutment
I & R Driver
SONIR002
> Used to Insert and Remove Inner Caps and Block Processing Male
Ball Abutment
Cuff
Diameter
Ø4.0
INNO-SUB. SHORT IMPLANT
1 2SBAT414R
Outer Cap O-ring
2 2SBAT424R
4.45mm
3 2SBAT434R Submerged Short Fixture
SUB. Note
4 2SBAT444R HEXAGON Surface Treatment : SLA-SH®
> For Healing Abutment and Prosthetic Component
5 2SBAT454R SYSTEM > Interchangeable with Hexagonal Morse Tapered Fixture Selection, Refer to "INNO Submerged Implant System"
Socket > Internal Hex Connection (Taper 11°/ Hex 2.5)
on the Page from 31 to 54 since the platform is the same as
> Utilize a Mount and Abutment of The INNO Sub. System
"INNO Submerged Implant System" (Hex 2.5)
D
> Ball Driver
4mm Hex 2.5
C KRB19L
*&YUSB1SPEVDU
Ball Abutment
> Packing Unit : 1 Ball Abutment + 1 Socket (1 Outer Cap + 1 O-ring )
> For Implant Supported Over-denture Prosthesis
> Tightened with Ball Driver and Torque Wrench 1(Machined Surface)
> Tightening Torque Force : 30 N.cm
> Direct Impression 2(Sandblast)
Socket
L(SLA)
BATC004
Outer Cap O-ring > Packing Unit : 4 Sockets
D
Diameter
Ø5.5 4
Length
Ball Analog 1
2
4 2ST5504S
D
L
L
Diameter D
Length Ø4.0
4 SBAL400
Less than 8mm
> Packing Unit : 4 Lab Analogs Diameter 4
Ø6.0
> Replacement of Abutment Shape in Cast Model Length
1
2
4 2ST6004S
L
061p 061p
Fixture Level
Procedure I
Impression
Prosthetic
Hex 2.1
Length
8 / 10 / 12 / 14mm
Diameter
Ø3.1 / 3.3
065p
Abutment Level
Procedure II
Prosthetic
Impression
Direct
Impression
Straight
Narrow Implant
Submerged Pre-Mount > Packing Unit : 1 Fixture + 1 Cover Screw + 1 Mount
8 SR3108NS
L
Submerged Fixture 10 SR3110NS
SUB-N. ※ Note
HEXAGON Surface Treatment : SLA-SH® 12 SR3112NS
> INNO Sub. Narrow System is not compatible with
SYSTEM > Interchangeable with Hexagonal Morse Tapered Fixture INNO Submerged System as hexagon size is different 14 SR3114NS D
12 SR3312NS
14 SR3314NS D
Fixture Mount
L L
Length 5.4
RSM001
D Cover Screw
Length 1.7 2.7 3.7
L RCS000 RCS001 RCS002
> Packing Unit : 1 Cover Screw
No-Mount > Packing Unit : 1 Fixture + 1 Cover Screw > To Seal the Conical Interface of Fixture
> Longer Cover Screw for Deeply Inserted Fixture
Diameter > Tightened with 1.2 Hex Driver
Ø3.1
Length > Tightening Torque Force : 5~10 N.cm
8 SR3108NSM 8 10 12 14
L
10 SR3110NSM Healing Abutment Diameter Ø3.5 Ø4.5
12 SR3112NSM Length
1 2 1 2
D Cuff
14 SR3114NSM D
HR3501
0.5
L
C 1 HR3511 HS4511N
2 HR3522 HS4522N
Diameter
Ø3.3 3 HR3532 HS4532N
Length
4 HR3542 HS4542N
8 SR3308NSM 8 10 12 14 5 HS4552N
10 SR3310NSM L 7 HS4572N
12 SR3312NSM > Packing Unit : 1 Abutment
14 SR3314NSM > For Remodeling Gingival Contour during Soft Tissue Healing
D
> Select According to Gingival Height and Abutment Type
> Tightened with 1.2 Hex Driver
> Tightening Torque Force : 5~10 N.cm
Narrow Implant
Prosthesis Procedure I Hybrid S Ti-Base
Components Selection Guide for Ti-Base, Cemented and UCLA Abutment D
1.2 Hex.
Type Hex
2.25 L
2.25 Diameter Ø4.0
C Length
Cuff 3.75
L
0.8 SLH404N
Abutment Screw 2 SLH424N
3 SLH434N
> Packing Unit : 1 Ti-Base + 1 Abutment Screw > Library available for EXOCAD®, 3Shape®,
> For Screw-Cement or Screw Retained Abutment Dental Wings® and Others
> Titanium Base for Strength of CAD/CAM Customized > Connected with Abutment Screw (SSHR100N)
Zirconium Abutment or Crown > Tightened with 1.2 Hex Driver and Torque Wrench
> Gold Color for More Translucent Restoration > Tightening Torque Force : 30 N.cm
> Lingual Surface Hole for More Esthetic Restoration > Use Scanbody for 3D Work
> Right Angled for Anti-Rotation of Prosthesis > Fixture Level Impression
Hybrid L Ti-Base
D
1.2 Hex.
Type Hex
L Diameter Ø4.0
2.25
Length
C Cuff 5.5
L 1 SLH415N
Model Scanning Method 2 SLH425N
3 SLH435N
Scanbody Replica
> Packing Unit : 1 Ti-Base + 1 Abutment Screw > Library available for EXOCAD®, 3Shape®, Dental
> For Screw-Cement or Screw Retained Abutment Wings® and Others
> Titanium Base for Strength of CAD/CAM Customized > Connected with Abutment Screw (SSHR100N)
Zirconium Abutment or Crown > Tightened with 1.2 Hex Driver and Torque Wrench
> Gold Color for More Translucent Restoration > Tightening Torque Force : 30 N.cm
> Cutting Surface for Anti-Rotation of Prosthesis > Use Scanbody for 3D Work
> Fixture Level Impression
Narrow Implant
Cemented Abutment Meta G UCLA Abutment
D 1.2 D
Abutment Screw
1.2 Hex.
Angulated Abutment
Diameter
15° / 25° 2.25 Length 2.25
10.2 SSHR100N
1.2 Type Hex
L
L > Packing Unit : 1 Abutment Screw
Diameter(Angle) Ø4.5(15°) Ø4.5(25°)
> Tightened with 1.2 Hex Driver and Torque Wrench
Length
C Cuff 8 8 > Tightening Torque Force : 30 N.cm
1 SAH45151NA SAH45251NA
D
2 SAH45152NA SAH45252NA
3 SAH45153NA SAH45253NA
Hex
4 SAH45154NA SAH45254NA
1.2
Type Hex N-Hex
Narrow Implant
Pick-up Impression Coping
D
2 Pieces Type
Diameter
Hex
Ø4.5
N-Hex
Ø4.5
Prosthesis Procedure II
L Length
9 (Short) SIH45SN SIN45SN
Component Selection Guide for Straight Abutment
11 (Long) SIH45LN SIN45LN
(Short) (Long) (Short) (Long) > Packing Unit : 1 Pick-up Impression Coping + 1 Guide Pin
Hex N-Hex > For Open Tray Impression
> Connected with Guide Pin
> Tightened with 1.2 Hex Driver and Torque Wrench
Straight Abutment
Transfer Post
D
L
Type Hex N-Hex
Diameter
Length Ø4.5 Ø4.5
2 Pieces 1 Piece
9 (Short) STH45SN STN45SN Healing
Fixture Cover Screw Abutment
11 (Long) STH45LN STN45LN
(Short) (Long) (Short) (Long)
Hex N-Hex
> Packing Unit : 1 Transfer Post + 1 Guide Pin (Hex) / 1 Transfer Post (N-Hex, Solid)
> For Closed Tray Impression
> Connected with Guide Pin Straight Abutment
> Tightened with 1.2 Hex Driver and Torque Wrench D
Diameter Ø3.5
7 5.5 L Length [Cuff] 8 [0.5] 8 [1] 8 [2] 8 [3] 8 [4]
4
SR308 SR318 SR328 SR338 SR348
C
> Packing Unit : 1 Abutment
> For Cement Retained Prosthesis
> Integrated with Screw and Abutment
> Tightened with Shoulder Driver
> Tightening Torque Force : 30 N.cm
> Direct Impression
Fixture Level
Procedure I
Impression
Prosthetic
Cemented Angulated Meta G UCLA Replica Pick-up Impression Coping Transfer Post
Solid Positioning
Impression Cap Lab Analog Plastic Coping
Abutment Cap Cylinder
Solid
Octa 3.1
Platform
Ø4.8 / 5.9
Abutment Level
Shoulder
Impression
Diameter
Ø3.5 / 4.0 / 4.5 / 5.0 / 6.0
081p 082p 082p
Procedure IV
Prosthetic
085p 085p
Procedure V
Prosthetic
Ball Analog
Ball
Internal Implant No-Mount Cuff 1.8mm Fixture > Packing Unit : 1 Fixture + 1 Cover Screw
* Diameter
Ø3.5
Length
Internal Fixture * Platfrom : Ø4.8
INT. Surface Treatment : SLA-SH® 7 - C
OCTAGON 8 10 12 14
> Interchangeable with 1 Staged Internal Fixture
Platform
SYSTEM 8 IPT3508SM
> Internal Octa Connection (Taper 8°/ Octa 3.1) L
> No-Mount Type 10 IPT3510SM Fixture
Diameter
12 IPT3512SM
14 IPT3514SM
Octa 3.1
D
* Diameter
Ø4.0
Length
Platform * Platfrom : Ø4.8
7 IPT4007SM
C 7 8 10 12 14
8 IPT4008SM
10 IPT4010SM L
C 12 IPT4012SM
14 IPT4014SM
D
* Diameter
Ø4.5
Length
L 7 IPT4507SM
* Platfrom : Ø4.8
C 7 8 10 12 14
8 IPT4508SM
L
10 IPT4510SM
12 IPT4512SM
14 IPT4514SM D
* Diameter
D Length
Ø5.0
* Platfrom : Ø5.9
7 IPT5007SM C 7 8 10 12 14
INNO Fixture Code 8 IPT5008SM
L
10 IPT5010SM
I P T 40 10 S M Ex.)
SLA Cuff 1.8 No-Mount IPT4010SM
12 IPT5012SM
Type P=Cuff 1.8 body Diameter Length Surface Treatment Mount 14 IPT5014SM D
Internal Taper Ø4.0 10mm SLA No-Mount
* Diameter
Ø6.0
I T 40 10 S M Ex.)
SLA Cuff 2.4 No-Mount IT4010SM
Length
* Platfrom : Ø5.9
Type Cuff 2.4 body Diameter Length Surface Treatment Mount C 7 8 10 12
7 IPT6007SM
Internal Taper Ø4.0 10mm SLA No-Mount
8 IPT6008SM L
10 IPT6010SM
12 IPT6012SM
D
14 -
No-Mount Cuff 2.4mm Fixture > Packing Unit : 1 Fixture + 1 Cover Screw Cover Screw
D
Platform Ø4.8 Ø5.9
12 IT3512SM
14 IT3514SM D
* Diameter
Ø4.0
Length Headless Screw Diameter
Length Ø3.5
D 6 ICVR001
* Platfrom : Ø4.8
7 IT4007SM
C 7 8 10 12 14 > Packing Unit : 1 Headless Screw
8 IT4008SM L
> For Narrow Mesio-distal Distance
10 IT4010SM L > Tightened with 1.2 Hex Driver
> Tightening Torque Force : 5~10 N.cm
12 IT4012SM
14 IT4014SM
D
* Diameter
Ø4.5
Length
* Platfrom : Ø4.8
7 IT4507SM C 7 8 10 12 14
8 IT4508SM
Healing Abutment Platform Ø4.8 Ø5.9
L Fixture Dia. Ø3.5 / Ø4.0 / Ø4.5 Ø5.0 / Ø6.0
10 IT4510SM
D Diameter
Height Ø5.5 Ø6.6
12 IT4512SM H
2 IHCR020 IHCW020
14 IT4514SM D
3 IHCR030 IHCW030
4.5 IHCR045 IHCW045
* Diameter
Ø5.0 > Packing Unit : 1 Abutment
Length
> For Remodeling Gingival Contour during Soft Tissue Healing
* Platfrom : Ø5.9 > Select According to Gingival Height and Abutment Type
7 IT5007SM C
> Tightened with 1.2 Hex Driver
7 8 10 12 14
8 IT5008SM > Tightening Torque Force : 5~10 N.cm
L
10 IT5010SM
12 IT5012SM
14 IT5014SM D
* Diameter
Ø6.0
Length
* Platfrom : Ø5.9
C 7 8 10 12
7 IT6007SM
8 IT6008SM L
10 IT6010SM
12 IT6012SM
D
14 -
Type Octa
(Octa) (N-Octa) 1.2
Angle
(Octa) (N-Octa)
Length 15° 25°
Cemented Extension
Abutment Angulated Abutment Meta G UCLA Abutment 8 IAAR158A IAAR258A
Replica
Replica
Platform
Fixture Dia.
Length
Ø4.8
Ø3.5 / Ø4.0 / Ø4.5
Ø5.9
Ø5.0 / Ø6.0
Prosthetic Procedure II
L 12 IROR001 IROW001 Component Selection Guide for Solid Abutment
> Packing Unit : 1 Replica
> Mimicking of Conical Interface of Fixture
> Analog of Fixture for Cast Model
(Crown) (Bridge)
Plastic Coping
Transfer Post
Octa N-Octa > Packing Unit : 1 Transfer Post + 1 Guide Pin (Octa) / 1 Transfer Post (N-Octa, Solid)
2 Pieces 1 Piece
> For Closed Tray Impression
> Connected with Guide Pin
> Tightened with 1.2 Hex Driver and Torque Wrench
Solid Abutment
Healing
Fixture Cover Screw Headless Screw Abutment
Impression Cap
Platform Ø4.8
Fixture Dia.
L Length Ø3.5 / Ø4.0 / Ø4.5
8 IICR001
Positioning Cylinder
Platform Ø4.8
Fixture Dia.
Length Ø3.5 / Ø4.0 / Ø4.5
L 10.2 IPCR001
(Crown) (Bridge)
Shoulder Ø4.0 KRR19L Shoulder Ø5.0 KRW19L
Lab Analog
Crown Bridge
> Packing Unit : 1 Analog
> Replacement of Abutment Shape in Cast Model
> Choose According to Width and Length of Abutment
2.25mm
Ø5.4
Black H-Type Inner Caps
Block Out Processing
Outer Cap Spacer male
Analog
Outer Cap
Outer Cap Black Processing male
Code SONOC01
> Packing Unit : 2 Outer Caps and 2 Black Processing Male
> Black Processing Male : Inserted and Removed with I&R Driver
Impression Coping
Healing
Fixture Cover Screw Headless Screw Abutment
Ball Abutment
Prosthetic Procedure V Outer Cap O-ring
Diameter
Length Ø3.5
4 IBAT404R
Component Selection Guide for Ball Abutment 4.45mm
KRB19L
D
L
*Extra Product
Socket
> Packing Unit : 1 Ball Abutment + 1 Socket (1 Outer Cap + 1 O-ring )
> For Implant Supported Over-denture Prosthesis
Ball Abutment > Tightened with Ball Driver and Torque Wrench
> Tightening Torque Force : 30 N.cm
> Direct Impression
Socket
BATC004
Ball Analog > Packing Unit : 4 Sockets
Outer Cap O-ring
Outer Cap
BATC003C
Ball Abutment
O-ring
BATC003I
Ball Analog
Healing D
Fixture Cover Screw Headless Screw Abutment
L
Diameter
Length Ø4.0
4 SBAL400
092p 092p
Fixture Level
Prosthetic
Impression
092p 093p 093p Replica Pick-up Squared Transfer Post
Impression Coping
Platform
Ø4.1 / 5.1
Length
Procedure II
7 / 8 / 10 / 12 / 14mm
Prosthetic
Abutment Level
Impression
098p 099p
Procedure III
Prosthetic
External Implant Pre-Mount > Packing Unit :1 Fixture + 1 Mount + 1 Mount Screw
* Diameter
Ø3.5
Length
External Fixture
EXT.
HEXAGON Surface Treatment : SLA-SH® 7 -
SYSTEM > Interchangeable with External Hexagonal Fixture 8 ET3508S
> External Hex Connection (Hex 2.7 / 3.4) 10 ET3510S
12 ET3512S
14 ET3514S
Platform 7
8
ET4007S
ET4008S
10 ET4010S
12 ET4012S
14 ET4014S
* Diameter
Ø4.5
Length
L 7 ET4507S
8 ET4508S
10 ET4510S
12 ET4512S
14 ET4514S
* Diameter
Ø5.0
Length
D
7 ET5007S
8 ET5008S
INNO Fixture Code 10 ET5010S
12 ET5012S
E T 40 10 S Ex.) 14 ET5014S
Type body Diameter Length Surface Treatment Mount SLA Pre-Mount ET4010S
External Taper Ø4.0 10mm SLA Pre-Mount
* Diameter
Ø6.0
Length
7 ET6007S
8 ET6008S
10 ET6010S
12 ET6012S
14 -
Fixture Mount
D
Hex Hex2.7 Hex3.4 Component Selection Guide for Cemented & UCLA Abutment
L Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Diameter
Length Ø4.9 Ø5.5
7.2 MER001 MEW002
Cover Screw
Healing Abutment
Hex Hex2.7 Hex3.4
D
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
L
Diameter
Length Ø5.0 Ø6.0
2.8 HNR502 HNW602
3.8 HNR503 HNW603
Replica
4.8 HNR504 HNW604
5.8 HNR505 HNW605
6.8 HNR506 HNW606
7.8 HNR507 HNW607
Healing
Fixture Cover Screw Abutment
Cemented Abutment (Hex) Meta G UCLA Abutment Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
Type Hex
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Hex Hex2.7 Hex3.4
D
1.2 1.2 Length
Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Cuff 13 13 13 13
Platform [Fixture Dia.]
1.2 GHR001N GHW001N GNR001N GNW001N
Diameter Ø5.0 Ø6.0 L
L
Length
6 8 6 8 > Packing Unit : 1 Abutment + 1 Abutment Screw
Hex Cuff
> For Screw-Cement or Screw Retained Prosthesis
C Platform 1 CHR516 CHR518 CHW616 CHW618 C > Modification to Angulated Abutment, Customized Abutment and Telescopic Abutment
2 CHR526 CHR528 CHW626 CHW628 Hex N-Hex > CCM Alloy Core for Precise Connection
> Cast with Non-Previous Metal or Gold Alloy
3 CHR536 CHR538 CHW636 CHW638
> Connected with Abutment Screw
Hex 4 CHR546 CHR548 CHW646 CHW648 > Tightened with 1.2 Hex Driver and Torque Wrench
> Tightening Torque Force : 35 N.cm
> Fixture Level Impression
Type N-Hex
Cemented Abutment (N-Hex) Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Platform [Fixture Dia.]
Plastic Sleeve Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
Diameter Ø5.0 Ø6.0
D 1.2 Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Length
Cuff 6 8 6 8 1.2 Length
Cuff 11.8 11.8 11.8 11.8
1 CNR516 CNR518 CNW616 CNW618
L 1.2 PHR001 PHW001 PNR001 PNW001
L
2 CNR526 CNR528 CNW626 CNW628
> Packing Unit : 1 Abutment + 1 Abutment Screw
C 3 CNR536 CNR538 CNW636 CNW638 > Same Purpose of Use as Meta G UCLA Abutment but Low Accuracy of Connection
4 CNR546 CNR548 CNW646 CNW648 C > PMMA Material
Hex N-Hex > Connected with Abutment Screw
> Packing Unit : 1 Abutment + 1 Abutment Screw > Tightened with 1.2 Hex Driver and Torque Wrench > Tightened with 1.2 Hex Driver and Torque Wrench
N-Hex > For Cement Retained and Screw-Cement Retained Prosthesis > Tightening Torque Force : 35 N.cm > Tightening Torque Force : Finger Light Force during Wax Pattern Fabrication, 35 N.cm after casting
> Cutting Surface for Anti-rotation of Prosthesis > Fixture Level Impression
> Connected with Abutment Screw Abutment Screw
Hex Hex2.7 Hex3.4
1.2 1.2
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Angulated Abutment Length 8 8
Hex Hex2.7 Hex3.4 Hex2.7 Hex3.4
L SHR100 SHW100
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
15° 25° 1.2 > Packing Unit : 1 Abutment Screw
Angle 15° 15° 25° 25° > Tightened with 1.2 Hex Driver and Torque Wrench
Length
Cuff 8 8 8 8
L
2 AAR152 AAW152 AAR252 AAW252 Replica Hex Hex2.7 Hex3.4
C
3 AAR153 AAW153 AAR253 AAW253 Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
4 AAR154 AAW154 AAR254 AAW254 L Length 12 12
LHR001 LHW001
> Packing Unit : 1 Abutment + 1 Abutment Screw
> For Screw-Cement or Cement Retained Prosthesis > Packing Unit : 1 Replica
> Solution for Anterior Esthetic Zone > Mimicking of Conical Interface of Fixture
> Conneced with Abutment Screw > Analog of Fixture for Cast Model
> Tightened with 1.2 Hex Driver and Torque Wrench
> Tightening Torque Force : 35 N.cm Pick-up Squared Impression Coping
> Fixture Level Impression
Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
Temporary Abutment L Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] IHR500 IHW600 INR500 INW600
L
Length
12 12 12 12 > Packing Unit : 1 Pick-up Impression Coping + 1 Guide Pin
Cuff Hex N-Hex > For Open Tray Impression
1.5 THR001 THW001 TNR001 TNW001 2 Pieces
> Tightened with 1.2 Hex Driver and Torque Wrench
C
> Packing Unit : 1 Abutment + 1 Abutment Screw Transfer Post
> For Screw-Cement Retained Prosthesis
Hex N-Hex > For Provisional Restoration Type[Hex] Hex[2.7] Hex[3.4] N-Hex N-Hex
> Connected with Abutment Screw Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
> Tightened with 1.2 Hex Driver and Torque Wrench L
> Tightening Torque Force : 20 N.cm Length 13 13 13 13
IHR510 IHW610 INR510 INW610
> Packing Unit : 1 Pick-up Impression Coping + 1 Guide Pin
Hex N-Hex > For Closed Tray Impression
2 Pieces > Tightened with 1.2 Hex Driver and Torque Wrench
D Platform [Fixture Dia.] Ø4.1 [Ø3.5 / Ø4.0 / Ø4.5] Ø5.1 [Ø5.0 / Ø6.0]
Diameter Ø4.8 Ø5.9
L
Length
Cuff 4 5.5 7 4 5.5 7
C 1 SAB414 SAB415 SAB417 SAB514 SAB515 SAB517
2 SAB424 SAB425 SAB427 SAB524 SAB525 SAB527
3 SAB434 SAB435 SAB437 SAB534 SAB535 SAB537
Impression Cap Positioning Cylinder
Bridge
4 SAB444 SAB445 SAB447 SAB544 SAB545 SAB547
2 Pieces
> Packing Unit : 1 Abutment
> For Cement Retained Prosthesis
> Dual Anti-rotation Grip for Prevention of Screw Loosening
> Integrated with Screw and Abutment
> Tightened with Shoulder Driver
> Tightening Torque Force : 35 N.cm
> Abutment Level Impression : Impression Cap in Platform Ø4.1 Fixture and Direct Impression in Platform Ø5.8 Fixture
Shoulder Abutment Cap
L
9.2 IASR170 IASW170
Healing
Impression Cap
Fixture Cover Screw Diameter Ø5.6 Ø6.7
Abutment Length
8 IICR001 IICW001
Positioning Cylinder
Diameter Ø4.4 Ø5.5
Length
10.7 SAPR001 SAPW001
L
> Packing Unit : 1 Cyilnder
> Inner Cutting Surface for Anti-rotation on Abutment
Prosthetic Procedure III
D > Insert into Impression Cap
Component Selection Guide for Ball Abutment
Lab Analog
D Socket
Type Crown Bridge
L
Diameter Ø4.8 Ø5.9 Ø4.8 Ø5.9
Length
4 SLCR040 SLCW040 SLBR040 SLBW040
5.5 SLCR055 SLCW055 SLBR055 SLBW055
7 SLCR070 SLCW070 SLBR070 SLBW070
Crown Bridge
> Packing Unit : 1 Analog
> Replacement of Abutment Shape in Cast Model
> Choose by Abutment Length
Ball Analog
Ball Abutment
Healing
Fixture Cover Screw Abutment
*Extra product
Socket
BATC004
Outer Cap
BATC003C
> Packing Unit : 2 Outer Caps
O-ring
BATC003I
> Packing Unit : 4 O-rings
* While the 2.2 Drill is used at 1000 RPM and irrigation must be accompanied,
the drills from 3.5 to 5.0 should be used at 50 RPM without irrigation.
Drill Sequence
Drill
Ø3.5
Point Ø2.2 Ø3.5 Countersink
Point Drill Ø2.2 Drill Ø3.5 Final Drill Ø4.0 Final Drill Ø4.5 Final Drill Ø5.0 Final Drill
KPD01S 2KTD22 2KTD35 2KTD40 2KTD45 2KTD50
Ø4.0
Stopper Countersink Point Ø2.2 Ø4.0 Countersink
Ø4.5
8 Drill Stopper 10 Drill Stopper 12 Drill Stopper Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink
Point Ø2.2 Ø3.5 Ø4.5 Countersink
KSDS08S KSDS10S KSDS12S 4KCS35 4KCS40 4KCS45 4KCS50
Normal Bone Hard Bone
Extension & Driver
Ø5.0
01
> Fixture Driver for INNO Sub. Fixture placement, the rest of component is for Sub. / Int. / Ext. [KCA010F] SUB.
HEXAGON
INT.
OCTAGON
EXT.
HEXAGON
SYSTEM SYSTEM SYSTEM
Ø2.2x8
Point Drill > Primarily used for marking the implant recipient site and to determine spacing.
8 8 8 8 8
> The point drill has a unique pointed tip, making this an excellent drill for starting the osteotomy
Final Drill
1.2 Hex Driver through the hard cortical plate.
Ø2.2x10 10 10 10 10 10
L Length 15
7
Mount Driver KPD01S
Ø2.2x12 12 12 12 12 12 31.8 3.5
Machine Ratchet
Path Drill > Used for the case that path modification is required
Machine Long Ratchet Long
> Excellent ablation force that does not slip in slanted bone
> Easy to drill even in extraction socket without slipping
14
12
10
8 Length 15
Ø3.5 Fixture Ø4.0 Fixture Ø4.5 Fixture Ø5.0 Fixture Ø6.0 Fixture 7
Final Drill Final Drill Final Drill Final Drill Final Drill 3 2KTD18
Ø2
Path Drill Point Drill Ø2.2 X 7 Ø3.5 X 7 Ø4.0 X 7 Ø4.5 X 7 Ø5.0 X 7 Ø6.0 X 7
2KTD18 KPD01S KPSD2207 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007
Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8 Length Band 7mm Fixture
KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008 Ø2.2 Initial Drill > Initial stepped Drill - Ø2.2 / Ø2.8 / Ø3.3 mm 8mm Fixture
stepped osteotomy at Ø1.8 Drill site 10mm Fixture
18.5 4 L 12mm Fixture
14mm Fixture
1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10 Length 8 9 11 13 15
KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010
KPSD2207 KPSD2208 KPSD2210 KPSD2212 KPSD2214
M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12
KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012
3.5 / 4.0 / 4.5 Drill Stopper with irrigation groove
Sub. Fixture Driver 2.2 Drill
4.9
Ø4.9 Crestal cutter – flattening the slopped and sharp crestal ridge which
M. Fixture Driver. S R. Fixture Driver. L Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14 2.5 make crestal bone surround around the whole fixture platform
3.3
2KMMS01S 2KHDS01L KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014 Ø3.3/2.8 Pilot cutter – stepped hole guiding the pathway of Ø3.5 / Ø4.0 /Ø4.5
1.5 2.8
fixture final drill
M. Fixture Driver. L R. Fixture Driver. XL Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink Ø2.2 Path cutter – determining the orientation of fixture installation
2KMMS01L 2KHDS01X KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
Initial drill Guiding the pathway of final drill.
Final drill is inserted a half into initial drill’s hole
without reduction of drill.
Torque Wrench Depth Gauge
A common tool for
KTW001 KDG004 Sub. / Int. / Ext. An exclusive tool by type
Final Drill > Ø3.5, 4.0, 4.5, 5.0, 6.0 diameter fixture’s final drills Tap Drill
> 7, 8, 10, 12, 14 mm fixture’s final drills in length > Used in preparation of osteotomy in dense bone only.
Ø3.5
18.5 4 L Fixture Dia. Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0
Fixture Dia.
Length Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0 Ø4.0
3KMTD35A 3KMTD40A 3KMTD45A 3KMTD50A 3KMTD60A
8 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007 Ø4.5
*Extra product
9 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008 Ø5.0
Countersink > Bone quality 1 : high compressive placement of fixtures induces the failure of osseointegration
and bone loss. > Insert Parallel Pin after Ø2.2 or Ø3.5 drill to check the osteotomy path.
Parallel Pin
> Countersink decreases torque force. (Ø4.0 Fixture : 80 N.cm -> 45 N.cm / Ø5.0 Fixture : 150 N.cm -> 45 N.cm) > In order to prevent losing Parallel Pin in patient’s mouth, be sure to tie floss through the hole
D
> Preventing compressive necrosis of dense cortical bone. in the Parallel Pin.
28.6 L
Fixture Dia. Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0 After Ø2.2 Initial After Ø3.5 Final
Length 21
Diameter Ø3.7 Ø4.2 Ø4.6 Ø5.1 Ø6.0 Drilling Drilling
KPP002
4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
1mm
1mm
Drill Extension > Used for lengthening the drill when using a hand-piece.
> Do not go over recommended torque when using the Drill Extension.
Multi Countersink L
Mount Driver > Used to install Pre-Mount Type Fixtures. Fixture Driver > Used to install No- Mount Type Fixtures.
Type Ratchet
Sub.
System
Length Sub. Int. Ext.(Hex 2.7) Ext.(Hex 3.4)
*Extra product
Torque Wrench > Torque control in implant placement and abutment connection.
Type
> 10 / 25 / 30 / 35 N.cm Torque force able to be controlled by pulling the elastic bar.
L Ratchet
> Maximal 120 N.cm Torque force with pulling the rigid main bar.
Hex
Length Hex 0.9 Hex 1.2
15(Short) KHD0915 KHD1215 Code KTW001
21(Long) KHD0921 KHD1221
27(X-Long) KHD0927 KHD1227
*Extra product
Depth Gauge > Measuring the drill depth with scaled rod.
> Measuring the 5 mm space between adjacent fixtures with flat end of the other side.
Code KDG001 20
18
16
14
12
10
8
> One side of Depth Gauge measures the Drilling depth and the other side
measures the gingival height from the top of the implant.
Code KDG004
02
※ Sloped edentulous ridge adjacent of tooth > Crestal cutter of initial drill and final drill
> Longer drills than fixture’s length
> Minimal drill frequency with Point Drill, Ø2.2 Initial Drill and Final Drill > Length Marking
(Ø3.5, Ø4.0 and Ø4.5 fixtures)
Ø2.2 Initial Drill Final Drill 12mm Drill 10mm Fixture
Crestal Flatting Longer Final Drill
20
18
16
※ Wide extraction socket
14
12 > Absence of the cortical bone & spongy bone
10 > Narrower diameter than the fixture’s diameter
8
> The pumping action of drill removes the bone chip in the hole.
> In dense bone, the debriment action decrease the high torque force.
Point Ø2.2 Ø3.5 Ø4.0 Ø4.5 Ø5.0 Ø6.0
Ø4.5
Ø5.0
※ In weak bone quality 4 of maxillary tuberosity
> No pumping action
Ø6.0
> 0.5mm deeper placement of fixture
> Wider fixture than final drill
> Ø5.0 fixture: a series of point drill, Ø2.2 Initial drill, Ø4.0 final drill and Ø5.0 final drill
> Ø6.0 fixture: a series of point drill, Ø2.2 Initial drill, Ø4.0 final drill, Ø5.0 final drill and Ø6.0 final drill
0.5mm deeper Level
Level Crestal level 0.5mm Deeper Level
Debriment with without with without
Ø4.5 Fixture 4.4 10.2 - 12.9
※ Countersink and Tap drill used in hard bone quality Ø5.0 Fixture 11.6 19.9 14.1 24.5
Ø4.5 Drill Ø5.0 Fixture
*Extra product
4mm 5m 7mm
Fixture Line Fixture Line Fixture Line
Drill Sequence
Normal Bone Hard Bone
Drill Ø5.0
Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Countersink
Point Drill Ø2.0 Step Drill Ø4.0 Step Drill Ø4.5 Step Drill Ø5.0 Step Drill Ø5.5 Step Drill Ø6.0 Step Drill
Normal Bone Hard Bone
KPD01S KSSD2004 KSSD3304 KSSD4504 KSSD5004 KSSD5504 KSSD6004
Stopper Countersink
4
Ø5.5 Countersink
Point Ø2.0 Ø4.0 Ø4.5 Ø5.0 Ø5.5
12 Machine
10
Drill Ø 3.3 Fixture Driver
Stopper Fixture
8
Ø 3.1
Fixture Mount Driver
Ø 2.6
Parallel Pin
Countersink Type
Ratchet Long
Ratchet Machine
Ø 2.2 KRMD19L KMMD12X
L
Spare L *&YUSBQSPEVDU
> Used to Install Fixture
Point 1.2 Hex Driver
Depth Gauge
Ratchet Machine
Torque Wrench
8mm Drill Stopper 10mm Drill Stopper 12mm Drill Stopper Point Drill Ø2.2 Twist Drill Ø2.6 Twist Drill Ø3.1 Twist Drill Ø3.3 Twist Drill
KNDS08 KNDS10 KNDS12 KNPD20 KNSD22L KNSD26L KNSD31L KNSD33L
Parallel Pin
33.1
Code KPP003
Depth Gauge
Ø3.1 Countersink Ø3.3 Countersink Fixture Driver(Ratchet) Fixture Driver(Machine) Parallel Pin 1.2 Hex Driver L
4KCS31N 4KCS33N KHDS01XN KMMS01XN KPP003 KHD1221 KDG001 After Ø2.2 After Ø3.1 / Ø3.3
Drilling Drilling
KTW001
Normal Bone
Point Drill Drill Sequence Hard Bone
42
Diameter Ø1.9
15
D KNPD20
Twist Drill
Diameter Ø2.2 Ø2.6 Ø3.1 Ø3.3
Ø3.1
KNSD22L KNSD26L KNSD31L KNSD33L Ø3.1
Point Ø2.2 Ø2.6 Ø3.1 Countersink Normal Bone
D Stopper Hard Bone
9.5
11 8mm Drill Stopper 10mm Drill Stopper 12mm Drill Stopper
13
15 KNDS08 KNDS10 KNDS12
42
Countersink
34.4
Diameter Ø3.1 Ø3.3
7.4 Ø3.3
D 4KCS31N 4KCS33N Point Ø2.2 Ø2.6 Ø3.3 Ø3.3
Countersink
INNO INT. FULL SURGICAL KIT INNO EXT. FULL SURGICAL KIT
INT. EXT.
OCTAGON HEXAGON
SYSTEM SYSTEM
> For the Selction and Use Guide of the Components for the Sub. Int. & Ext. Surgical Full Kit, refer to page 103 to 109. > For the Selction and Use Guide of the Components for the Sub. Int. & Ext. Surgical Full Kit, refer to page 103 to 109.
> Fixture Driver for INNO Int. Fixture placement, the rest of component is for Sub. / Int. / Ext. > Fixture Driver and Multi Countersink for INNO Ext. Fixture placement, the rest of component is for Sub. / Int. / Ext.
[KCA010FI] [KCA010FE]
Ø2.2x8 8 8 8 8 8 Ø2.2x8 8 8 8 8 8
Final Drill
Final Drill
1.2 Hex Driver 1.2 Hex Driver
Ø2.2x10 10 10 10 10 10 Ø2.2x10 10 10 10 10 10
Ø2.2x12 12 12 12 12 12 Ø2.2x12 12 12 12 12 12
Counter sink
Counter sink
Machine Short Ratchet Short Drill Extension Machine Short Ratchet Long Drill Extension
Hex 2.7 Hex 2.7
Spare
Spare
Ø3.5 Fixture Ø4.0 Fixture Ø4.5 Fixture Ø5.0 Fixture Ø6.0 Fixture Ø3.5 Fixture Ø4.0 Fixture Ø4.5 Fixture Ø5.0 Fixture Ø6.0 Fixture
Final Drill Final Drill Final Drill Final Drill Final Drill Final Drill Final Drill Final Drill Final Drill Final Drill
Path Drill Point Drill Ø2.2 X 7 Ø3.5 X 7 Ø4.0 X 7 Ø4.5 X 7 Ø5.0 X 7 Ø6.0 X 7 Path Drill Point Drill Ø2.2 X 7 Ø3.5 X 7 Ø4.0 X 7 Ø4.5 X 7 Ø5.0 X 7 Ø6.0 X 7
2KTD18 KPD01S KPSD2207 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007 2KTD18 KPD01S KPSD2207 2KTD3707 2KTD4007 2KTD4507 2KTD5007 2KTD6007
Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8 Parallel Pin Parallel Pin Ø2.2 X 8 Ø3.5 X 8 Ø4.0 X 8 Ø4.5 X 8 Ø5.0 X 8 Ø6.0 X 8
KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008 KPP002 KPP002 KPSD2208 2KTD3708 2KTD4008 2KTD4508 2KTD5008 2KTD6008
1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10 1.2 Hex Driver L 1.2 Hex Driver XL Ø2.2 X 10 Ø3.5 X 10 Ø4.0 X 10 Ø4.5 X 10 Ø5.0 X 10 Ø6.0 X 10
KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010 KHD1221 KHD1227 KPSD2210 2KTD3710 2KTD4010 2KTD4510 2KTD5010 2KTD6010
M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12 M. Mount Driver. L R. Mount Driver. L Ø2.2 X 12 Ø3.5 X 12 Ø4.0 X 12 Ø4.5 X 12 Ø5.0 X 12 Ø6.0 X 12
KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012 KMMD06L KRMD19L KPSD2212 2KTD3712 2KTD4012 2KTD4512 2KTD5012 2KTD6012
M. Fixture Driver. S R. Fixture Driver. S Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14 M. Fixture Driver. S R. Fixture Driver. L Ø2.2 X 14 Ø3.5 X 14 Ø4.0 X 14 Ø4.5 X 14 Ø5.0 X 14
KMMI01S KHDI01S KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014 KMME01S KHDE01L KPSD2214 2KTD3714 2KTD4014 2KTD4514 2KTD5014
M. Fixture Driver. L R. Fixture Driver. L Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink M. Fixture Driver. S R. Fixture Driver. L Drill Extension Ø3.5 Countersink Ø4.0 Countersink Ø4.5 Countersink Ø5.0 Countersink Ø6.0 Countersink
KMMI01L KHDI01L KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60 KMME02S KHDE02L KDE002 4KCS35 4KCS40 4KCS45 4KCS50 4KCS60
[KPA003]
> Sub. Implant system
> Try-in Kit for determining abutment specifications
SUB. HEXAGON
SYSTEM Prosthetic Kit
Abutment Gauge > Measuring of the diameter, cuff length and angulation of abutment
7
5.5
4
4
2 3
1
Cuff 2 Cuff 4 15° / Cuff 2 15° / Cuff 4 25° / Cuff 2 25° / Cuff 4
2SAG002 2SAG004 2SAG152 2SAG154 2SAG252 2SAG254
Abutment Driver > Used in Shoulder, Solid, Absolute, and Straight abutment placement
Shoulder Ø4.0 Shoulder Ø5.0 Hex 1.2 Ratchet Hex 1.2 Machine Tissue Punch
KRR19L KRW19L KHD1221 KMD12L KTP001 2 Pieces
Trephine soft tissue over
cover screw of fixture
AMCI001 AMCL001
Lab Analog
> Packing Unit : 1 Analog
Surface Treatment : SLA-SH®
> When top portion is altered, same adjustment must
> Uniform micro-surface geometry, increased BIC,
be made for lab analog.
and improved surface wetness
Length
Protect Cap
7mm AMCC001
9mm AMCC002
Diameter
11mm AMCC003
Diameter
> Packing Unit : 1 Cap
> For semi-permanent or temporary solution for overdenture prosthesis Diameter Diameter
Ø2.5 Ø3.0
Cuff Cuff
Length
2.0mm 4.0mm Length
2.0mm 4.0mm
4.45mm
> This is taken by shoulder on Abutment, and, after impression taking,
4.2 Easy Delivery using ball type drivers it is taken with Lab Analog to be able to make model of oral cavity.
Socket
Cuff
Socket
BATC004
Outer Cap O-ring > Packing Unit : 4 Sockets
Length
O-ring
BATC003I
> Packing Unit : 4 O-rings
Diameter
Impression Coping
> Packing Unit : 1 Coping
> Impression Coping is used for impression taking of Ball Post.
Ø2.35(Ø2.0 Implant)
Point Drill
Multi Gauge *Extra product > Allows precise measurement of drilling depth and path
KPD03L 36.8mm
Length 30
20
Ø1.3 Twist Drill KDGP19 Ø1.9 18mm 16mm 14mm 12mm 10mm
Driver Ø3.0
Cement Type Ball Type
Point Drill Ø2.3 Twist Drill Ø3.0 Implant (12mm)
Machine KMDC31L Machine KMDB27L
Soft Bone Soft Bone
D3 / D4 D3 / D4
1 32
2 31
3 30
4 29
5 28
COWELL ®
MPIS-32
6
27
7
26
Right Left
14 19
15 18
16 17
Mandible
MFS KIT
MFS KIT
MFS KIT
[KSA004]
Multi-Functional Sinus™ Kit
> Approach all maxillary Sinus Lift at Once with MFS kit.
Ø2.2 X 13
Ø2.8 X 13
Ø3.3 X 13
Ø3.7 X 13
Ø4.2 X 13
Bone Carrier
Aqua Lifter Ø2.8 Ø3.3 Ø3.7 Ø4.2
Aqua Tube
Bone Condenser
Depth Gauge
Torque Wrench
Sinus Elevator
0.5
3
CSE-02
0.5mm 1mm 1.5mm 2mm 2.5mm 3mm
CSE-03
Ø6 Lateral Ø6 Round Ø4
MFS KIT
Crestal Approach - Components 4. Crestal Drill Stopper
> Connected with a stopper to be drilled to the same length of the cartilage height of maxillary sinus which is measured by CT
> If you don't have CT, tighten the stopper one step lower than expected and gradually increase the length.
Code KPD01S Drilling Depth 1mm 2mm 3mm 4mm 5mm 6mm
KSDS01 KSDS02 KSDS03 KSDS04 KSDS05 KSDS06
Code KSTD22 12
9 Code KDG001S
6
3
0
Diameter Band 12 11 10 9 8 7 6 5 4 3 2 1
Ø2.8 Aqua Syringe Connector
Ø3.3 ※ It is convenient to measure Depth by ※ Flat floor edge minimize damage
Ø3.7
standard as a 3,6,9,12mm. to Membrane. Code KSAL01SC
Ø4.2
Aqua Tube
Code KSALT030
MFS KIT
7. Torque Wrench
> Use the Torque Wrench to fix aqua lifter in the hole formed using crestal drill. Crestal Approach - Drill Sequence
Code KTW001
8. Bone Carrier
> Insert Bone graft material using Bone Carrier.
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill
Ø3.9
Soft Bone Normal Bone
Ø3.5
2. Ø3.5(Ø3.7) Fixture
※ If you need to expand hole,
Code KSBC01
drill 1mm more using the
crestal drill
9. Bone Condenser
> After connecting stopper with Bone Condenser, Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill
elevate bone graft materials to inside of maxillary sinus or
Soft Bone Normal Bone
> Rotate bone graft material using Bone Condenser to disperse bone
graft material (It is possible to do it with Depth Gauge)
Ø2
3. Ø4.0(Ø4.2) Fixture
※ If you need to expand hole,
drill 1mm more using
the crestal drill
Ø1
Code KSBC1022
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill Ø3.7 Crestal Drill
Point Drill Ø2.2 Twist Drill Ø2.8 Crestal Drill Ø3.3 Crestal Drill Ø3.7 Crestal Drill Ø4.2 Crestal Drill
11. Implant Placement
Soft Bone Normal Bone
> To get initial fixation, if the residual bone is less than 3mm,
do not place the implant, only do bone grafting.
※ it is needed final drilling before placing implants in the case of more than Ø5.0 Fixture Normal Bone
※ Use a drill that is one step shorter than the implant (Ex. 10mm implant, 8 ~ 9mm Drill)
MFS KIT
Lateral Approach - Components > CSE-02 : as stepwise, after using CSE-01, used for elevation of sinus membrane
Code KSLD60
Code KSSE03
Code KSC60
Code KSLRD60
4. Sinus Elevator
> CSE-01 : CSE-01 Initial Elevation of Sinus Membrane
Code KSSE01
8. Implant Placement
MFR KIT
MFR Kit - Components
MFR KIT Multi-Functional Removal™ Kit
[KHA001]
1. Fixture Removal System
① Fixture Removal Screw connect to FRS Driver
② Connect to Fixture (Clockwise 40~60 N)
Easy Removal of Fractured Fixture / Screw / Abutment ③ Fixture Remover connect to F/R Screw (Counterclockwise)
Abutment Removal System
④ Eliminate Fixture after connecting to Torque Wrench (Counterclockwise, 100~400 N.cm)
Abutment Remover ⑤ To remove the fixture from Fixture remover, use Vise to fix the Fixture Remover and connect to Torque Wrench
⑥ F/R Screw connect to FRS Driver and then use Torque Wrench to eliminate F/R Screw (Counterclockwise)
Tap Repair ④
①
⑤
Tap Repair Driver
KTR16 / KTR20 / KTR25 ③
M1.6 M2.0 M2.5 ②
⑥
Slot Machine
Driver Adapter
※ it is recommended only one time to use F/R Screw (if more than 100 N.cm , there is a possibility to fracture or bend),
but it is possible to use twice if it is less than 100 N.cm
Fixture Removal System Screw Removal System ※ Sufficient Irrigation required for removing fixture
※ When the maximum torque is exceeded, the fixture may be bent or fractured.
F/R Screw
Talon Reverse Screw ※ If fixture can not be removed even with maximum torque, remove Fixture Remover & F/R Screw,
Drill Drill Remover
remove bones around fixture while using Round Bur and retry to remove
Fixture Remover Screw Fixture Remover Screw Fixture Remover Screw M1.6
KFRS16 KFRS20 KFRS25 2. Screw Removal System
M1.6 M2.0 M2.5
Talon Drill
Fixture Remover FRS Driver
M2.0 ① Screw is broken inside the fixture (check the broken screw size)
② I Guide for Fixture Connection
Ø3~Ø4 Attached to guide holder and fastened to fixture
Fixture Removal Fixture Removal(Sub Narrow)
Taron Drill Reverse Guide Screw
KFR3515 / KFR3520 KFRSD13 / KFRSD18 (Claw Drill) Drill Remover ③ Insert Talon Drill into I Guide Hole
M2.5 KSRCD08 KSRGD08 KSRSR08 ④ Remove the screw by pressing force (counterclockwise, 60 ~ 80 rpm)
KSRCD12 KSRGD12 KSRSR12
KSRCD14 KSRGD14 KSRSR14
Ø4~Ø5
Fixture Removal
KFR4015 / KFR4020
I Guide ④
Ø5~Ø6 Fixture Removal I Guide (Sub 2.5 Hex) I Guide (Internal 3.1 Octa) ③
KFR5015 / KFR5020 KSRIG25H KSRIG31O ②
Torque Wrench
KTW002 Silicon O Ring KSRIGO01
①
Guide Holder KSRGH01
※ If I Guide and fixture can not be correctly connected, the path is not correct.
MFR KIT
Reverse Drill & Screw Remover Tap Repair
If the screw could not be eliminated by Talon Drill ① thread which is inside of Fixture is occluded and damaged
① Hole is formed on the fractured screw (depth 1 ~ 2mm / counterclockwise / 1,200 ~ 1,400 rpm) ② reproduce Thread using Tap Repair ②
② Use Screw Remover according to the created drill hole, remove the screw by pressing force (counterclockwise, 80 N.cm) ①
Slot Driver
① 1 Piece Type abutment is fractured. Healing and Cover screw damaged
② Forming Slot on the surface of fractured abutment using Round Bur
① ③ Slot Driver will be connected to Slot on the surface of Fractured
Abutment and eliminate it(Counterclockwise)
※ If the path of I Guide and Fixture does not match, it is difficult to remove the screw because the Drill Hole is away from the
center of the screw
※ Reverse Drilling requires removal of chip by Irrigation & Suction
※ Fractured screw may be removed during reverse drill hole creation
※ If necessary, fasten to machine adapter and connect hand and torque wrench. 4. Torque Wrench
③
②
Fixture Removal (Counterclockwise, 100~400 N.cm)
①
Instruction
10mm
7 7 10mm Stent
Ø2
Place
INNO • which type of the abutments to be used in the
site according to Implant’s specification
Fixture
or
Characteristic
> Guide the position of the implant and drill during when you place implant. Place • After placing INNO Fixture,
> It improves the stability and accuracy in surgery, and it can shorten the time. Lock Connect Lock Abutment according to the site
* If implant placement at an angle is not appropriate or not desired,
> By preventing the loss of healthy gums as much as possible, pre-fabricated prostheses can be placed immediately after Abutment using INNO SUB. SHORT Implant is highly recommended.
surgery without the need for gum restoration.
138 MULTI-UNI DIRECT SURGICAL STENT MULTI-UNI DIRECT SURGICAL STENT 139
COWELL®BMP Trephine Kit
[KBT001]
Trephine DrillⳒ Block Bone Extraction
This drill allows the collection of block-type autogenous bone with a required size in the case of regenerating a wide bone
defect and severe bone resorption.
An easy-to-use kit containing drills for block-type bone collection and failed fixture
removal in autogenous bone graft, and Bone Chip Extraction Prior to Implant Placement. Block Bone Guide Block Bone Trephine Drill
> This guide helps the target block bone to be accurately > This drill is engaged with the bone groove with the help
positioned and the trephine drill to be stably engaged of the block bone guide to collect the block bone
with the bone. with a desired size.
> Desired rpm: 800~1,000 rpm > Desired rpm: 800~1,000 rpm
Ø6
Ø7
Ø8
Ø6
Ø7
Ø8
7.5
7
5
3
0
Ø 6.0 Ø 7.0 Ø 8.0 Ø 6.0 Ø 7.0 Ø 8.0
Ø 7.0 Ø 8.0 Ø 9.0 Ø 7.0 Ø 8.0 Ø 9.0
Diameter Ø 6.0 (Inner) Ø 7.0 (Inner) Ø 8.0 (Inner) Diameter Ø 6.0 (Inner) Ø 7.0 (Inner) Ø 8.0 (Inner)
KBGT60 KBGT70 KBGT80 KBT60 KBT70 KBT80
Trephine DrillⳒBlock Bone Extraction
Guide & Block Bone Trephine Drill
ⴙ ⴘ
Trephine Drillⳓ Trephine DrillⳔ
Failed Fixture Removal Window Opening for
Lateral Window Approach
Fixture Removal Window Trephine
2mm
Ø4 Ø4.5 Ø5 Ø7
Ø 4.5
Ø4
Ø5
Ø 8.0 (Inner) KBT80
140 COWELL® BMP TREPHINE KIT COWELL® BMP TREPHINE KIT 141
COWELL®BMP Trephine Kit
Atraumatic Extraction
Trephine DrillⅢ Window Opening for Lateral Window Approach
Diameter Ø 7.0 (Outer)
ATRAUMATIC EXTRACTION KIT [KAE001]
KWTT60 Atraumatic Exraction Kit is used for the immediate and effortless extraction of the root of the tooth
with simple procedures.
0.5
Implant Site Drill Sinus Lift & Bone Chip Extraction Prior to Implant Placement
(1) Diversity
Diameter
> A root extraction can be done regardless of whether residual amount of root is large or little.
Ø 3.5 Ø 4.0 Ø 4.5 Ø 5.0
KTIS35 KTIS40 KTIS45 KTIS50 (2) Safety
> A tooth extraction without the risk of directly damaging the tooth is possible by using the rest plate, elevator, etc.
> Used before the final drill is used (Simplified drill sequence)
> Advantageous for securing autogenous bone
(3) Convenience
> A very simple and convenient tooth extraction is possible, as compared to the existing extraction method.
> Less rpm drilling leads to low bone heating
Ø 3.5
Ø 4.5
Ø4
Ø5
> Also used as a sinus lift tool (socket lift elevation) (4) Reduced Procedure Time
> Desired rpm : 20~30 rpm > The procedure time is reduced due to the simple procedure.
8
6 Composition
4
Ø1.3
Ø2.1
Ø1.7
Bone Chip Extraction
Ø 1.3 Drill Ø 1.7 Drill Ø 1.8 Screw Ø 2.2 Screw Ø 2.1 Drill Ø 2.6 Screw
Elevator
Atraumatic Extraction
1. Extraction Drill 3. Post Driver
> The extraction drill is composed of three types of drills (Ø1.3 / Ø1.7 / Ø2.1) that can be selected according to the case. > After connecting the post driver to the extraction screw, turn the torque wrench in a clockwise direction in order to fix it to the
hole that was created by the extraction drill. (Recommended torque : 30 N.cm or more)
32 13
12
12
Ø7.9 Ø4.5
Ø1.3 Ø1.3 Ø1.7 Ø1.7
Ø2.1 Drill 32
12
* Connection with Extraction Screw
Ø2.1 Ø2.1
Code KAMD21
4. Rest Plate
> The rest plate is connected between the extraction screw and the torque head. It protects the part with silicon that comes into
2. Extraction Screw direct contact with the adjacent teeth in order to prevent tooth damage.
> The extraction screw is fastened into the hole that was created by the extraction drill via the screw method, and it is stably fixed It also serves as a support for the elevator and torque wrench.
to the remaining tooth. It is composed of the Ø1.8 / Ø2.2 / Ø2.6 screws that can be selected according to the extraction drill. > One side is inclined at a 30-degree angle, so that it can act as a support depending on the removal direction.
> Ø1.8 Screw is used for vital root of which canal is not treated, after using Ø1.7 Drill > The holes are created at a 5-mm interval in order to adjust the position of the extraction screw according to the position and
distance of the adjacent tooth.
37
Ø1.8 Screw
33
25 10
14
M2.5 Ø1.8
M2.5 Ø2.0
Code KATH80
Code KAMS25
Atraumatic Extraction
6. Elevator
>G The elevator is used by connecting it with the torque head and extracting the tooth by applying force toward a distal or mesial * Drilling Sequence
169
JXG JYG J\G
30˚
How to Use
1. Extraction Drill
Create a hole on the tooth to be extracted using an extraction drill.
Under Under
20 N.cm 20 N.cm
Caution A
- The extraction drill must follow the neural root canal during drilling.
NN
- Drill down to at least 10mm because extraction is possible even if the drill Ø 1.3 Drill Ø 1.7 Drill Ø 1.8 Screw Ø 2.2 Screw Ø 2.1 Drill Ø 2.6 Screw
and screw penetrate the dental root.
Caution C
- Fix the screw with a torque of 20 ~ 25 N.cm. If it is not applied, use a thicker screw.
2. Extraction Screw - The low torque force causes the screw to fall out during the extraction, and the overtorque force fracturatesthe root..
Connect the extraction screw to the post driver and fix it to the hole created by rotating it clockwise.
(Recommended torque: 20 N.cm minimum ~ 25 N.cm maximum)
3. Rest Plate
After removing the post driver, connect a rest plate to the extraction screw
by taking into account the adjacent teeth
CW
Caution B
- Drill to a depth of 10~12 mm and insert the extraction screw at a depth of 10 mm.
- Fix the screw with 20~25 N.cm.
Rest Plate
Atraumatic Extraction
Caution E
- If there are adjacent teeth with 2 or higher swaying degrees, upward pulling or downward pressing should be applied using
4. Torque Head an elevator so that the teeth will not receive force during extraction.
Connect the torque head to the extraction screw projected above the rest plate by rotating it clockwise.
CW
5. Torque Wrench
Extract the tooth by rotating the torque head clockwise using a torque wrench.
Caution F
- If there is an adjacent tooth projected to the mesiodistal root, it must be extracted using an elevator.
CW
Extraction Root
Extraction with fulcrum of distal tooth Extraction with fulcrum of mesial tooth
* When extracting the mesial tooth, * When removing the distal tooth, support the tooth
support the elevator in the distal direction and in the mesial direction and apply force upward to
Caution D apply force downward. Lift the tooth to extract it. extract the tooth.
- Extraction using the torque wrench is possible in a tooth with mesiodistal root.
Caution G
- A molar with two or more roots is a contraindication because the anatomical structure causes screw fracture during extraction.
Direct Surgical Guide Kit is used for a flapless surgery. It can also serve as a guide for positioning the drill while
measuring the thickness of the buccal bone, thereby preventing bone resorption and reducing the burden on the patient.
In addition, stable drill positions can be guided to various cases by combining different surgical instruments
(e.g., position guide, linker, and width guide).
Caution A Please fix the depth pin of the buccal position guide to the buccal bone surface 5mm below
the gingiva or the alveolar crest.
(1) Safety
> Safe operation is possible by measuring the thickness of the buccal bone in order to prevent buccal bone resorption.
5mm
(2) Reduced Pain
> It is possible to minimize the burden on the patient by reducing the pain and swelling from a flapless surgery without going
through the incision step that is carried out during the general implant surgery.
Caution B In a defective buccal bone or a thin buccal bone due to tooth extraction, fix the depth pin of the
buccal position guide to the surface 5mm below the gingival or the alveolar crest, from the
1. Buccal Position Guide
lingual or palatal side.
> Use the depth pin positioned at the bottom of the guide according to the bone width and fixture diameter.
This will enable you to maintain the buccal bone thickness of the implant. The guide should be connected to the guide holder.
Buccal Bone Thin Wall
>The length can be distinguished with the O-ring color of the post.
Defect
>Please be careful in using the depth pin because it is extremely sharp.
5.1mm
Sleeve
Post O-ring
6
8mm
Buccal Linker 2
150 DIRECT SURGICAL GUIDE KIT DIRECT SURGICAL GUIDE KIT 151
Direct Surgical Guide
Black O Ring
Under 7mm bone width,
Under Ø4.0mm Fixture
Ø 3.0
Ø 4.0
1mm 1.5mm
Ø7 Ø8 Ø9 Ø10
Red O Ring The width guide is used by connecting it with the sleeve of the buccal position guide.
Bone Width 7~9mm,
Ø 4.0
Ø 4.0
Ø4.0mm~ Ø4.5mm Fixture
Width Guide
2mm 2mm
Sleeve
Bucco-palatal Bone Width Fixture Diameter
Blue O Ring
Ø 4.0
Ø 5.0
Central Lateral
Mandible incisor incisor
Mesiodistal
dimension 5.4 6.0
152 DIRECT SURGICAL GUIDE KIT DIRECT SURGICAL GUIDE KIT 153
Direct Surgical Guide
Ø2.15
12
2nd
Maxilla Lat. Incisor 1st Premolar
Premolar
Mesiodistal
dimension
7.3 7.7 7.3
Ø 4.0
Ø 4.0
Ø 4.0
10
3mm 5mm 7mm
Ø2.15
9mm 11mm
7mm
Code K3PP07 Code K3PP09 Code K3PP11
* The position guide must be used in combination with the buccal position guide and linker.
It cannot guide the drill position accurately when used alone.
2nd
Mandible Canine 1st Premolar
Premolar
Application of 7 mm Position Guide
Mesiodistal
dimension 7.2 7.3 7.3 (When the mesiodistal distance between the two missing teeth is at least 14 mm)
2
3 3
4
4
5
5
4
Maxilla Mandible
Central 1st 2nd
Maxilla Incisor
Canine
Molar Molar
Mandible 1st Molar 2nd Molar
Mesiodistal Mesiodistal
9.2 8.3 10.5 9.5 dimension
11 10
dimension
154 DIRECT SURGICAL GUIDE KIT DIRECT SURGICAL GUIDE KIT 155
Direct Surgical Guide
5 6
Linker Sleeve
6 5
Position Guide Linker
Maxilla Mandible
7 ① The linker is connected to the position guide by setting the linker sleeve in a downward position.
② After connecting the linker by setting the sleeve of the buccal position guide in a downward position,
6
6 it can be used by adjusting it according to the mesiodistal distance.
7
Maxilla Mandible
> When you perform prosthesis with a bridge in a continuous implant, connect the 11mm linker to the position > The gingiva residue is removed while flattening the uneven alveolar bone surface.
guide and the buccal position guide to drill.
30.1
Ø2.2 Ø3.95
Code K3L11
11mm
156 DIRECT SURGICAL GUIDE KIT DIRECT SURGICAL GUIDE KIT 157
Direct Surgical Guide
Code KSRGH01
Ø2.8
1. Mesio-distal angle: parallel with adjacent tooth
Crestal Cutter
2. Bucco-lingual angle Guide Drill
Anterior : Match incisal edge Premolars: Match the buccal cusp Posterior: Match the centerline
* The angle of the guide can be predicted according to the shape of the tooth.
Fixture Installation Final Drill
Guide Handle
Drill
* After connecting the guide handle to the buccal position guide, fix it at the site where the
implant will be placed and insert the guide drill into the hole inside the sleeve.
158 DIRECT SURGICAL GUIDE KIT DIRECT SURGICAL GUIDE KIT 159
Hurricane Bone Collector
> An instrument that thoroughly retrieves the autogenous bone fragment and adult stem cells that have been 1. Assembly Method
discarded through the suction during drilling of the alveolar bone for implant placement.
① Centrifugal Tube & Cup assembly in Hurricane Body
② Assemble Suction Handle & Tip in use to Hurricane Bone Collector
Before Assembly
320mm 70mm
After Assembly
Composition
155mm
O-ring 5EA
Code KHBC001
3. Instruction
Depending on the situation, the instrument may work correctly at an incline of less than 15 ° in the vertical
direction, but in larger angles, the instrument may not work properly.
70~90°
① Insert the Centrifugal Cup downwards. ② Symmetrically, both horizontally and vertically, Caution B
insert the Centrifugal Tube in the Centrifuge. - In case of different height of collected specimen in centrifugal Tube, add saline solution to adjust
the level. Different height may cause unsatisfactory purification effect due to not properly functioning
centrifuge.
<Cleaning>
Caution A
1. After the procedure, suck 1L of distilled water or saline solution with suction device to remove blood and foreign
- The maximum volume of collected specimens is the amount of specimen generated during the substances inside the instrument.
operation of 2 or less implant placement per Centrifugal tube. 2. After disassembling the Hurricane adapted body, tube and cup, following to the instruction of manufacturer, dilute the
enzyme cleaner with tap water . Then proceed ultrasonic cleaning for 10 minutes then clean with tap water for 3 minutes.
- The maximum specimen volume to be collected in Centrifugal tube is 12ml, however appropriate
3. Completely drain with dry cloth or fan heater.
volume of specimen is 8~10ml of specimen to prevent flowing down during movement or operating
centrifuge.
<Sterilization>
1. Before use, sterilize for 15 minutes at 132℃ or at 135℃ for 10 minutes with a high pressure steam sterilizer .
2. Dry for 30 minutes after high pressure steam sterilizer.
3. Keep the sterilized instruments in clean environment at 15-30℃.
3. Application
A. Orthopedics
COWELL®BMP
4. Mechanism of Action of COWELL BMP Bone Graft 5. Product Type
A. Migration of Cells with lamellipodia COWELL® BMP Reagent (BMP Power ONLY)
B
[LOT No.] 18E02B
[MFG Date] 2018-02-05
adhesions
[EXP Date] 2020-02-04
[Packing Unit] 5 EA
extracellalar space
Cowellmedi Co., Ltd.
P13K Rho- 48, Hakgam-daero 221 beon-gil,
46986, Republic of Korea
Intergrins GTPase
www.cowellmedi.com Tel.+82-51-314-2028 Telefax.+82-51-314-2026
B. Cellular mechanisms
A : BISC BMP-2 B : PFC COWELL® BMP (One vial)
BRII BRI
DRM Clsthrin-
coated
pit > BMP-2 adheres to the membrane of BMP Coated
BCP Particle
stem cell and induces expression of BMP Powder
non-transcriptional
genes of nucleus. Then, BMP-2 migrates
to recipient site. BMP BMP Powder
+ BMP Coated BCP Particle
responses early
endosome
> BMP-2 growth factor, Twist-2
cytoskeletal transcriptional factor, and VEGF growth
rearrangements
factor synthesize and secrete
caveosome > Dose and Particle Size of COWELL® BMP
endogenous growth factor
Product Code Particle Size Product Code Particle Size Product Code Particle Size
COWELL®BMP
COWELL® BMP Plus (Two vials) INNO GF Kit (Two vials + Saline Solution + Syringe)
+
Saline Solution
+ +
& Syringe
> Dose and Particle Size of COWELL® BMP Plus > Dose and Particle Size of INNO GF Kit
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
EBB0125 0.1mg 0.25g 0.41~1.0mm EBB2525 0.25mg 0.25g 0.41~1.0mm IBB0125 0.1mg 0.25g 0.41~1.0mm IBB2525 0.25mg 0.25g 0.41~1.0mm
EBB0105 0.1mg 0.5g 0.41~1.0mm EBB2505 0.25mg 0.5g 0.41~1.0mm IBB0105 0.1mg 0.5g 0.41~1.0mm IBB2505 0.25mg 0.5g 0.41~1.0mm
EBB1110 0.1mg 1g 0.41~1.0mm EBB1125 0.25mg 1g 0.41~1.0mm IBB1110 0.1mg 1g 0.41~1.0mm IBB1125 0.25mg 1g 0.41~1.0mm
EBB1220 0.1mg 2g 0.41~1.0mm EBB1225 0.25mg 2g 0.41~1.0mm IBB1220 0.1mg 2g 0.41~1.0mm IBB1225 0.25mg 2g 0.41~1.0mm
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
Product Code BMP Dose Particle Dose Particle Size Product Code BMP Dose Particle Dose Particle Size
EBB0525 0.5mg 0.25g 0.41~1.0mm EBB1025 1mg 0.25g 0.41~1.0mm IBB0525 0.5mg 0.25g 0.41~1.0mm IBB1025 1mg 0.25g 0.41~1.0mm
EBB0505 0.5mg 0.5g 0.41~1.0mm EBB1050 1mg 0.5g 0.41~1.0mm IBB0505 0.5mg 0.5g 0.41~1.0mm IBB1050 1mg 0.5g 0.41~1.0mm
EBB1150 0.5mg 1g 0.41~1.0mm EBB1011 1mg 1g 0.41~1.0mm IBB1150 0.5mg 1g 0.41~1.0mm IBB1011 1mg 1g 0.41~1.0mm
EBB1250 0.5mg 2g 0.41~1.0mm EBB1012 1mg 2g 0.41~1.0mm IBB1250 0.5mg 2g 0.41~1.0mm IBB1012 1mg 2g 0.41~1.0mm
BMP 2mg
BMP 2mg
Product Code BMP Dose Particle Dose Particle Size
Product Code BMP Dose Particle Dose Particle Size
IBB2025 2mg 0.25g 0.41~1.0mm
EBB2025 2mg 0.25g 0.41~1.0mm
IBB2050 2mg 0.5g 0.41~1.0mm
EBB2050 2mg 0.5g 0.41~1.0mm
IBB2011 2mg 1g 0.41~1.0mm
EBB2011 2mg 1g 0.41~1.0mm
IBB2012 2mg 2g 0.41~1.0mm
EBB2012 2mg 2g 0.41~1.0mm
COWELL®BMP
6. User Guide COWELL BMP Bone Graft
A. Method I C. Method III
a. Transfer BCP graft material (Vial I) b. Inject distilled water into vial II with lyophilized
(+ autogenic / allograft into a container) rhBMP-2 power in it and mix with the powder
a. Inject distilled water into vial II with lyophilized b. Aspirate the mixture using a syringe
rhBMP-2 power in it and mix with the powder
c. Mix BMP solution with BCP or plus autogenic d. Cover the defect area using a barrier membrane or
/ allograft and apply into the recipient site suture natural soft tissue without membrane
c. Hydrate BMP-2 solution into membrane d. Apply BMP-2 solution socked membrane
to damaged site
B. Method II
BMP Dose Distilled Water Dose BMP Dose Distilled Water Dose
d. Mix rhBMP-2 with distilled water e. Aspirate the mixture using a syringe f. Inject BMP solution through
(saline solution) and wait for soft tissue until needle
10 to 15 mintues before using of syringe reaches bone
Inno-Oss™
7. Study Result on COWELL BMP Bone Graft
In vivo Study Inno-Oss ™ Allograft
FDBA, Cortical 50% Cancellous 50%
Control group BMP group
At surgery
Product Features
> This product is made up of human tissue from trusted donors
4 weeks whose gender, age, and medical history were checked to
after surgery ensure that their tissue could be used safely.
> It is an ideal combination of 50% cortical powder and 50%
8 weeks cancellous powder for bone induction.
after surgery
> The 50% Cortical powder maintains the space of the transplanted area during the new bone formation due to the delayed
absorption rate. [OsteoConduction]
Jung-Bo Huh, et al., Alveolar ridge augmentation using anodized implants coated with Escherichia coli-derived recombinant human bone > 50% Cancellous powder is rich in minerals and collagen that promote cell adhesion, bone remodeling, and vascular re-formation.
morphogenetic protein 2 (Beagle dog)
[OsteoInduction]
- Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011 - > To prevent cross-infection by a different donor, the process is done by a single donor.
> Under the higher-level pharmacological standards (medical criteria) of the American Association of Tissue Banks (AATB),
Histologic Findings : Tissue specimen collected approximately four months we sampled, processed, and distributed the allograft tissue.
after the maxillary sinus grafting (human)
> We recommend use of this product with the COWELL® BMP.
X400 > New bone was formed around the graft material.
X200
> No inflammatory reaction was observed in connective tissue.
SEM Image
> Proliferation of collagen fiber was observed.
> Proliferation of fibrocyte was observed.
> Osteoblast was observed on the surface of newly formed bone. Dose and Particle Size
Product Code Particle Size Particle Dose
Jung-Bo Huh, et al., Multicenter, randomized clinical trial on the efficacy and safety of Escherichia-coli-derived rhBMP-2
with β-Tricalcium phosphate and hydroxyapatite in human extraction sockets Turn and pull
Remove the syringe’s Hydrate it in saline Graft it in the
- J Adv Prosthodont 2011;4 -134
out the syringe
rubber cap. solution. desired area.
cap to remove it.
InnoFuse™
InnoFuse ™
An Advanced Demineralized Bone Matrix
DBM content comparison New bone formation comparison: Animal test result
> INNOFUSE™ has higher DBM content (35%) compared to the other conventional products, and it has excellent bone regeneration effect.
> INNOFUSE™ showed a 4 class higher in new bone formation and higher new bone regeneration capacity than the other conventional products.
INNO DERM™
InnoDerm ™
Acellular Dermal Matrix
Product Features
> This product can carry out the functional blocks of the membrane
(soft tissue penetration protection) due to its long absorption period,
and has excellent manipulability.
> Unlike other imported complete products, this product is produced
under the stringent standards of the FDA in Korea. 20kv, x70.0, 430㎛ 20kv, x70.0, 430㎛
> The world's first E-Beam sterilization can induce safe and prompt
engraftment. Normal Skin DERM Other Product
> E-Beam is safe and can be effectively sterilized without destroying the collagen tissue structure.
> This product is the first in the world with the basement membrane layer removed (patent pending) to maximize the transplant
engraftment rate.
> This shows the high engraftment rate after the transplant by maximizing the influx of fibroblasts and/or the neovascularization.
The world's first 'E-Beam' sterilization that does not destroy
(Patent Application No. 10-2012-0026616) the collagen structure
[Before
Application sterilization]
A. SEM (x200) B. SEM (x20,000) C. TEM (Transverse Section) D. TEM (Cross Section) Bacteria removal
Normal collagen
Destroyed collagen
Specifications EO chemical residue
Product Code Size Thickness
INNO-CaP
INNO-CaP Calcium Phosphate , Synthetic Bone Graft A porosity for new bone ingrowth
The porosity promotes ingrowth of osteoblast, osteoclast and growth factors.
Osteoconductive resorbable synthetic bone graft material Pariticle surface SEM image
INNO-CaP is a osteoconductive synthetic resorbable bone graft material consist of Calcium Phosphate.
INNO-CaP is completely resorpted and progressively replaced by normal-structured bone in the healing period.
Indications
Sinus graft surgery
> For sinus graft, INNO-CaP is used alone or in combination with the other graft materials.
> Various healing period according to residual bone height.
X1,000 X1,000
GBR (Guided Bone Regeneration)
> Minimize the amount of autogenous bone.
> Sub-graft materials.
IG1025 0.25g
IG1050 0.5g
0.41~1.0mm
IG1001 1g
IG1002 2g
IG1425 0.25g
IG1450 0.5g
1.0~1.4mm
IG1401 1g
IG1402 2g
BOSS
A. Structure of the product
Diameter Ø2.0
Diameter Ø4.0 Diameter Ø4.0
0.8
Advantages Cuff 3
7.7
Length
>G Maintains the width and height of adherent gingiva
The body is connected to the fixture The interface between body and Before covering, InnoGenic™ Ti-Plast /
maintaining the space for regeneration InnoGenic™ Ti-Plast / PTFE Plast / PTFE Plast / Ti-Mesh is shaped and the
Introduction of soft tissue. Ti-Mesh is fixed. intraoral position of those is determined.
Type 1 (BOSS Abutment ) : Placement of implant in the extraction socket B. User Guide
Connect abutment body to Fix the InnoGenic™ Ti-Plast / Suture the cover without additional incision
the guide and place the PTFE Plast / Ti-Mesh using the cover (if InnoGenic™ Ti-Plast is used, primary closer is
InnoGenic™ Ti-Plast / required). The result shall be much more
PTFE Plast / Ti-Mesh predictable and better if COWELL® BMP, rhBMP-2
solution is injected via gingiva into osseous
tissue in the bottom.
BOSS
Type 2 (BOSS Screw) : Placement of implant in cases other than theextraction socket Instrument
0.9 Hex Driver Product Code Size
BOSS Case
> Case for storage of the product > Can be autoclaved
KBC001
>GWhen implant cannot be placed or when implant is to be placed after two sessions of bone regeneration procedure
>GConsists of screw that can be fixed onto osseous tissue and guide
>GProtects bone graft material against external force using InnoGenic™ Ti-Plast / PTFE Plast / Ti-Mesh
Diameter Ø2.0
3 Diameter Ø3.2
27 3.2
Length 9.2
B. User Guide
>GSelect the screw with an appropriate width and height, and then fix using a dedicated screwdriver.
>GFill the blood-soaked bone graft material into the defective bone.
>GModify the shape of InnoGenic™ Ti-Plast / PTFE Plast / Ti-Mesh to prevent the bone graft material from escaping into the oral cavity.
>GConnect the screw and guide, place place the InnoGenic™ Ti-Plast / PTFE Plast / Ti-Mesh, and then fix using the cover.
>GSuture the cover without additional incision(if InnoGenic™ Ti-Plast is used, primary closer is required). The result shall be much more
predictable and better if COWELL® BMP, rhBMP-2 solution is injected via gingiva into osseous tissue in the bottom.
inserted and fixed into the hall of titanium frame allows displacement of the products.
>G Close to Transparency : Observation of the healing of the underlying tissue through almost transparent PTFE surface
InnoGenic™ Ti-Plast and InnoGenic™ PTFE-Plast allows more predictable result and helps determine removal time easier.
>GEasy to be Customized : Easy to modify the shape according to shape and dimension of the defect.
>G The InnoGenic™ Ti-Plast, PTFE-Plast and Ti-Mesh are non-resorbable surgical plaster to be applied over intraoral defects,
>GEasy to be Removed : Put a hook in the hole of the titanium frame of the InnoGenic™ Ti-Plast and in any center part of
especially, tooth extraction and bone augmented sites. The InnoGenic™ Ti-Plast and PTFE-Plast consist of proprietary
the InnoGenic™ PTFE-Plast and remove.
100% PTFE, the polytetrafluoroethylene (teflon) sheet which is a biologically inactive and tissue compatible material and
the InnoGenic™ Ti-Plast is reinforced with titanium frames (Titanium Gr II, ASTM F 67) embedded between two layers
of PTFE sheets.
SEM Photograph
BTP3040 30 x 40 0.2 Action on Exposure Instant Removal Removal on week 3 to 4 Safe for more than 6 weeks
Shielding Function
against Fiber Cell High High Extremely High
Shape-keeping Capability
Large Deformation Shrinkable Deformation No Deformation
against External Force
InnoGenic™ PTFE-Plast
TS17251 17 x 25 0.1
TS24301 24 x 30 0.1
TS17252 17 x 25 0.2
TS24302 24 x 30 0.2
TMP210 25 x 34 0.07
TMP211 25 x 34 0.1
Features
> Easy to be Customized : Easy to modify the shape according to shape and dimension of the defect
> Prevention of Displacement : Prevents displacement of the InnoGenic™ Ti-Mesh using the InnoGenic™ Abutment and
Screw inserted and fixed into the 1mm hole of the Ti-Mesh Frame.
> No Resilience : The problem of Majority of Titanium Meshes in the market is resilience of the products after certain time.
Due to this problem, patients go through serious pain. The InnoGenic™ Ti-Mesh is, however, made after many times of stamping
process, The InnoGenic™ Ti-Mesh does not come back to the original shape after shape is formed.