R
User sM anual
ED-B3-MA-050530-001
BA3240
DEAR CUSTOMERS:
Please read the user manual carefully before using BA-3240,and operate according
to the user manual strictly.Any questions, please ask for the local distributor.
CONTENTS
1 Attentions P3
2 Functions&features P3
3 Parameters P4
4 Front panel P5
5 Back panel P5
6 Power supply P6
7 Function setup and cable connection P7
8 Operations P9
9 Protection functions P9
10 Troubles and trouble shootings P10
1 ATTENTIONS
Do not open the cover because exist dangerous voltage,please ask the professional to repair
Do not expose it to the raining or moisture
Do not put it under the direct sunshine,high temperature or heat source
Keep good ventilation,not stop the ventilating hole
Note the local voltage must matched with the voltage required
Please put off the plug if not use for a long time
Connect with right load, not work under overload for a long time
Do not let the obstacle into the unit, keep the unit away the obstacles
Please stop using if the cable is damaged
Symbols:
The equilateral triangle with lightning bolt warns the user of dangerous voltage levels
localized within the cabinet.
The equilateral triangle with exclamatory mark means the important operation on the
user's manual.
2 FUNCTIONS&FEATURES
BA-3240 is a integrated amplifier with completed functions,can meet the demand
of small public address system separately.
1.> Five channels input
INPUT1-INPUT4 can be choosed to be balanced microphone input with low impedance,
built-in 24V eidolon power microphone input or line balance input with high impedance.
INPUT5 is unbalanced line input with high impedance,INPUT1 is fault channel,can control
other channel output
2.> Balanced rated voltage output with 120V 100V 75V 50V 25V, 4 Ohms rated
impedance output and 8 /1W monitor output are optional
3.> Can external connect equipments
4.> Separately volume control for each channels,the total volume control is also available
and convenient
5.> HF/LF adjust
6.> Seven sections LED indicators
7.> Separated areas with Six channels
8.> The DC 24V interface is available under the urgent situation to provide the power supply
when the local voltage has problems
9.> Power supply is optional for 110V/220V
10.> Auto power off function under Output short circuit,over loading, overheat protection
3
3 PARAMETERS
MODEL BA3240
THD<1% RMS 240W
Frequency response +0/-3dB 50Hz-16KHz
8 /1W monitor 4-16 rated impedance
Output terminal
25V 50V 75V 100V 125Vrated voltage
INPUT SENSITIVITY/IMPEDANCE
INPUT1-INPUT4 microphone input 10mV/1K Balanced
INPUT1-INPUT4 line input 200mV/30K Balanced
INPUT5 input 200mV/50K Unbalanced
THD <0.5% @1KHz 24W
S/N RATIO: (A-WEIGHT)
Microphone >70dB
Line >80dB
REC OUT/impedance 1V/1K
TONE CONTROL
LF > 6dB @100Hz
HF > 6dB @10KHz
Mute >36 dB
Power supple1 99V-121V AC 50/60Hz
Power supply 2 198V-242V AC 50/60Hz
Dimensions(W*H*D) 316 88 250mm
Net weight 15.6Kg
Gross weight 16.4Kg
4
4 FRONT PANEL
2 3 4 5 6 7
Beta Three PRO Public Address Amplifier BA3240
OUTPUT LEVEL
1 2 3
POWER -36 -30 -24 -18 -12 -6 0 (dB)
0 0
4 5 6
0 10 0 10 0 10 0 10 0 10 -10dB +10dB -10dB +10dB
0 10
INPUT 1 INPUT 2 INPUT 3 INPUT 4 INPUT 5 BASS TREBLE VOLUME 6 ZONE
POWER
8 9 10 11 12 13
1 Signal indicator for input 1 8 Volume control for channel 1 5
2 Signal indicator for input 2 9 LF Adjust
3 Signal indicator for input 3 10 HF Adjust
4 Signal indicator for input 4 11 Total volume control
5 Signal indicator for input 5 12 Channel switch for area 1 6
6 ON/OFF indicator for area 1~6 13 Power
7 Output level indication
5 BACK PANEL
2 3 4 5 6 7 8
VOLTAGE SELECTOR ZONE OUTPUT
CAUTION !
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REC OUT AUX IN
~110V/~220V
50-60Hz L L
CH1 CH2 · ÖCH3
Ê
ÇäøÈë CH4 CH5 CH6
INPUT 5 INPUT 4 INPUT 3 INPUT 2 INPUT 1
RMS 240W POWER OUTPUT ZONE POWER
INPUT STANDBY
R R
CHANNELS
COM 8 /1 W 4 25V 50V 70V 100V 120V 0V 24V/15A 24V PHANTOM 24V PHANTOM 24V PHANTOM 24V PHANTOM
MONITOR
MIC MIC MIC MIC
POWER
240VA LINE LINE LINE LINE
Elder Audio Manufacture Co., Ltd INSERT
9 10 11 12 13 14 15 16 17
1 110 / 220V Power Switch 10 Power amplifier output clip
2 Distribution zone output terminal 11 Distribution terminal clip
3 Recording output terminal 12 24V/10A DC voltage
4 Channel 5 input 13 Insert terminal
5 Channel 4 input 14 Channl input 4 terminal
6 Channel 34 input 15 Channl input 3 terminal
7 Channel 2 input 16 Channl input 2 terminal
8 Channel 1 input 17 Channl input 1 terminal
9 Power supply
5
6 POWER SUPPLY
Please ensure that the back voltage showing is according with the local voltage
This unit have voltage selector, can be used for different voltage
Before operation, please chck the local voltage is optional for the 110/220V selector voltage,
you can connect it if correct and optional. If not optional, please put the selector to the correct
voltage value, please note cut off the power supply when select.
The operation as:
230V 115V
THIS IS OPTIONAL FOR 220V THIS IS OPTIONAL FOR 110V
Be sure that the power input socket is good, power cable is not damaged when
connecting, Please power off when not using unit.
The normal working voltage is 250VA, the peak power cost about 600VA.
Note:
When selected to 220V, please use 2.5A 5*20mm delay style fuse
When selected to 110V, please use 5A 5*20mm delay style fuse
Please use the correct fuse when voltage power changed
Note that the voltage will be put to 220 when leaving factory
6
7 FUNCTION SETUP AND CABLE CONNECTION
1> Unit connecting
Signal For example Mic/ cd/NL4/receiver)
Zone 3 Zone 4
Zone2 Zone 5 Mic 1
Zone1 Zone 6
VOLTAGE SELECTOR ZONE OUTPUT
CAUTION !
RISK OF ELECTRIC SHOCK
DO NOT OPEN
REC OUT AUX IN
~110V/~220V
50-60Hz L L
CH1 CH2 · ÖCH3
Ê
ÇäøÈë CH4 CH5 CH6
INPUT 5 INPUT 4 INPUT 3 INPUT 2 INPUT 1
RMS 240W POWER OUTPUT ZONE POWER
INPUT STANDBY
R R
CHANNELS
COM 8 /1 W 4 25V 50V 70V 100V 120V 0V 24V/15A 24V PHANTOM 24V PHANTOM 24V PHANTOM 24V PHANTOM
MONITOR
MIC MIC MIC MIC
POWER
240VA LINE LINE LINE LINE
Elder Audio Manufacture Co., Ltd INSERT
Insert equipment
Monitor speaker Storage Line output recoring or amplifier supplying power
Power output to zone
distribution(note correct voltage
2> input plug connecting
SIGNAL 2 1
3 INPUT1-INPUT4 is unbalanced input, as left connecting
SIGNAL
SIGNAL GROUND
SIGNAL 2 1
3
SIGNAL
INPUT1-INPUT4 is balanced connecting, as left connecting
SIGNAL GROUND
Note:
Channel input1 is priority channel, should be inserted urgency microphone or
fire fighting signal.
7
7 FUNCTION SETUP AND CABLE CONNECTION
3> input sensitivity:
You should know the signal character before connecting,
then connect to this unit correct channel.
24V PHANTOM 24V PHANTOM 24V PHANTOM
MIC MIC MIC
LINE LINE LINE
A B C
A indicates that the channel is set to 24V phantasm microphone input, the input
sensitivity is 10mV
B indicates that the channel is set to microphone input, the input sensitivity is 10mV
C indicates that the channel is set to line input, the input sensitivity is 200mV
4> Insert equipment connecting
Line input Insert equipment
Line output Signal Ground
Connected equipment can be selected based on your need,
please connect as above drawing
5> Zone distribution connecting
Connect correct output voltage to the zone terminal based on your needs
6> Output connecting
Please select correct voltage of broadcast to connect with relative interface of the BA3240
Can connect many loudspeaker in parallel connection.But the total power can not be over 240W
8
8 OPERATIONS
PLEASE OBEY THE FOLLOWING:
1 Start
a set the right function and connect the right cable
b check the output line and see if it is short circuit or loading is too low
c check the local voltage is same as the require of power
d adjust the volume to Min
e connect the power supply,then open the sound source,pre and effect equipments,
must sure all equipments work well
f Open the power supply,and sure the indicator is lit up
g Adjust the volume to right place clockwise
2 Put off
a adjust volume to Min. counter-clockwise
b put off the power supply,and sure the indicator off
c put off the pre and effect equipments and sound source equipment
3 Volume adjust
Connect the input signal and open the sound source,adjust the volume,if the indicator
is not lit up,please check the sound source.Adjust according to the voltage output and
the signal.When 0dB output voltage is lit up,the output is RMS, if is too much,will cause
the distortion
4 Area setting
Six buttons and six yellow indicators, when the six indicators are lit up, it means that
there are output in six areas,press the area button, the relative area will be closed and
the indicators will be off
9 PROTECTION FUNCTIONS
BA-3240 Completed functions give the amplifier and speaker a good protection to avoid
the damage, like short circuit,overloading,and overheat.
1 Circuit protect: when exist the short circuit,it will be off automatically
2 Cverload protect: it will be off automatically when input impedance is too low
3 Overheat protection: if the temperature heatsink is over the standard degree.
If the unit will be back to required range,the nuit will be back to home
9
10 TROUBLES AND TROUBLE SHOOTINGS
Status Solutions
1 Check power plug connection
No sound,and the
2 Check the voltage 220V/110V
indicator is not lit up
3 Check the fuse
1 Check the input signal
No sound, the power
indicator is lit up,
2 If open the power supply and adjust the volume
And signal indicat
or is not lit up
3 Check the volume electroform
1 The output is too big or not
Overload indicator
is too right.the 2 Check the sensitivity setting
sound is not good
3 Check the volume is too big or not
Signal indicator is Check the output connecting,
1
normal,no output Check The loading
1 Check the local voltage
Fuse damaged
2 Check the fuse specification
Check if the setup and connection are accordant with
1
the user manual
Others
2 Ask for the distributor
If it does not work according to the above steps,please ask for the professional to repair.
10
R
User sM anual
BA3240