42 May 2018

P&I Loss Prevention Bulletin


The Japan Ship Owners’
Mutual Protection & Indemnity Association Loss Prevention and Ship Inspection Department

Cyber risk and


Cyber security countermeasures
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

Contents

1. Introduction...........................................................................................................................1

2. Example of a ship communications system that has been infected with a virus..................................2

3. Preparation needed to manage cyber security countermeasures ...............................................5

4. Selecting designated IT personnel ........................................................................................ 10

5. Establish an IT standard in your organization......................................................................... 11

6. Implementing an IT standard risk assessment ....................................................................... 13

7. SMS manual to include IT control documents ........................................................................ 13

8. Conclusion.......................................................................................................................... 14

9. Appendix............................................................................................................................. 14

Text and forms provided by ORCA CO., LTD.


1. Regulation for the Organization of the Safety Management System MN-02-00…………………………… 15

2. Chart of Organization for the Safety Management System MN-02-00A……………………………………… 16

3. Regulation for management of IT systems MN-20-00………………………………………………………… 17

4. Procedure for management of IT systems MN-20-01………………………………………………………… 22

5. Guideline for IT system integration MN-20-01A… …………………………………………………………… 27

6. Procedure for Cyber Risk Management MN-20-02… ………………………………………………………… 31

7. Record for IT Standard design SM0750………………………………………………………………………… 33

8. List of the IT Systems SM0751… ……………………………………………………………………………… 36

9. Records for Risk Assessment of the IT Systems SM0752… ………………………………………………… 37

⿙⿙Our club’s original poster … …………………………………………………………………………………… 38

< Note >
Regarding the text and forms provided by ORCA CO., LTD. which were introduced in this bulletin, ORCA CO., LTD.
possess the primary copyright. However, we have permission to duplicate, edit, revise and distribute only for the
purpose of Club member SMS manual revision.

< Disclaimer >
This Loss Prevention Bulletin is issued for the purpose of supporting Club members and related parties with cyber
security countermeasure planning. The Japan Ship Owners’ Mutual Protection & Indemnity Association and ORCA
CO., LTD. are not liable for any damage caused as a result of using this bulletin.
JAPAN P& I CLUB

§1 Introduction

The threat of cyber attacks at sea have increased recently and our Club issues a circular entitled “Cyber risk and cyber
security” accordingly. The necessity of cyber security countermeasures and guidelines have been set forth by the IMO
(MSC-FAL.1/Circ.3 Guidelines on Maritime Cyber Risk Management) and each shipping organization.

1 -1 Cyber risk and P&I insurance

Cyber risks have not been specified in the Japan P&I


Club rules, however, a claim regarding the coverage of
a cyber attack or cyber breach would be examined in the
usual way with reference to the Rules. When the cyber
attack would not fall under the definition of "war" or "act
of terrorism" under rule 35, a member will be subject to
cover along with his normal P&I insurance. Sponsored by FURUNO 

For example, the following case would normally be New Generated Bridge System Voyager

subject to P&I insurance: The ship’s system gets infected with a virus via the onboard LAN system via the e-mail
PC used for work or a crew member’s personal PC. The onboard PC’s software for work use is updated without
permission or, as a result that particular crew member changed connection to the onboard LAN cable without
permission. The electronic aid for navigation and propulsion breaks down, which causes damage to harbour facilities
at the time of departure.

The following examples will not be covered by P&I insurance: For instance, there was a case whereby a certain
amount of the ship’s store was transmitted mistakenly due to a hacked e-mail. In another case, the ship’s schedule
was delayed because the crew was investigated by the authorities, because the uploaded video which was found in
his personal PC appeared to be associated with terrorism. Further, a threatening email was sent to the ship as a fake
money demand meaning that the ship might have been arrested. Such cases which do not develop into P&I accidents
were reported.

-1-
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

§2 Example of a ship communications system


that has been infected with a virus

2-1 Ship communications

Except for GMDSS (Global Maritime Distress and Safety System, which is equipment that is installed on a
ship depending on the sea area that is to be sailed), V-SAT, Fleet Xpress, FBB, Iridium, internet using 4G,
e-mail, telephones and Faxes are frequently used on the ship. This ship communication equipment is not only a
communication tool between ship and shore, but also essential equipment for current navigation, such as weather
routing, chart correction and PMS (Planned Maintenance System).
The volume of ship communications via e-mail have increased due to this. Graph 1 shows the volume of ship
communications via e-mail by month over the last 12 years. Compared with 2005, the volume of communications in
2016 has increased by 18 times.

(Unit:MB)

160
144
140 Volume of ship communications(e-mail) 126
120

100
76
80
65
61
60 48 53

40
36
20 24
20 15
8
0
2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 2016

Graph 1  Volume of ship communications via e-mail by month over the last 12 years

-2-
JAPAN P& I CLUB

2-2 Example of a system infected with a virus

On the other hand, along with the volume increase in ship communications, the number of ship systems that are prone
to being infected with a virus are also occurring more frequently, and the way in which viruses infect systems are now
more varied.
By around the year 2000, ship viral infection was blocked by the e-mail provider. When it came to ship's local
network, because most vessels were not initially connected to an external network, there were many cases whereby
people or crew who boarded the ship brought viruses on board with them physically.

Server scanning

Updating definition files

ship's local network

e-mail with Virus

Virus from crew


2000
Fig. 2 Around 2000

However, since around 2010, there have been some cases whereby an intrusion of the latest virus caused the ship to be
infected and, as a result, disrupted the e-mail system. This came about as a result of a member of crew using 3G/4G
when calling at port.

-3-
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

Server scanning
private 3G/4G
Updating definition files connection by crew

ship's local network

e-mail with Virus

Virus from crew


2010
Fig. 3 Around 2010

Actions such as the use of illegally copied software and illegally downloaded sites, as a result, are some of the causing
circumstances whereby a system may be easily infected by the latest virus.
It is needless to say that these ship communications devices and their connected onboard PCs, navigation electronics
and propulsion equipment etc. are essential when it comes to examining cyber security countermeasures. However,
there seems to be little known when it comes to taking a specific approach concerning the examination of risk
assessment, revisions to the SMS (Safety Management System) or SSP (Ship Security Plan).
In the last part of this bulletin, we will take a look at ORCA CO., LTD., which has practical accomplishments in the
shipping IT field, and introduce a SMS template that simulates the MSC-FAL.1/Circ.3 Guidelines on Maritime Cyber
Risk Management, using the risk assessment approach method for cyber security countermeasures.

-4-
JAPAN P& I CLUB

§3 Preparation needed to manage cyber


security countermeasures

3 -1 How to prevent cyber risk

Here, we would like to define cyber risk as potential factors which may cause problems or affect the IT system which
may even also cause disorder in the carrying out of duties and lead to economic loss.

This can be defined as anything to do with a ship’s computer’s software,


IT system
hardware, system, equipment and appliances, namely, Information Technology.

Identify the IT systems used Identify the risks associated


for work related use with the IT systems

Evaluate the risk

Implementation of
Risk tolerance
countermeasures

3 - 2  Explanation of Class NK technical information (No. TEC-1145)

Regarding IACS, the importance of security countermeasures of a computer system are to be considered. In order to
specify the requirements related to a person’s role in a computer system used on board, security countermeasures of
both software and hardware to be used in the computer system and the quality of management, such as the procedure
of software changes etc., the Unified Requirement of IACS E22(Rev.2) was adopted in June, 2016.
Following this, a notice of revised related rules and inspection procedures in the Class NK technical information

-5-
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

guideline (No. TEC-1145) was issued on February 28, 2018.


In the Class NK technical information guideline (No. TEC-1145), regarding each piece of software and hardware
that performs automatic control or remote control installed on board, they were classified according to the extent of
influence they exert by disorder. Further, responsibilities and duties were distinguished according to shipyard, system
integrator, supplier and shipowner.

Table 2.1 System categories in Annex D18.1.1, Part D of the Guidance for the Survey and Construction for Steel Ships
Category Effects Typical system functionality
Those systems, failure of which will not lead to
- Monitoring function for informational or administrative
Ⅰ dangerous situations for human safety, safety of the
tasks
vessel and/or threat to the environment.

- Alarm and monitoring functions


Those systems, failure of which could eventually lead
- Control functions which are necessary to maintain
Ⅱ to dangerous situations for human safety, safety of the
the vessel in its normal operational and habitable
vessel and/or threat to the environment.
conditions

Those systems, failure of which could immediately lead - Control functions for maintaining the vessel’s
Ⅲ to dangerous situations for human safety, safety of the propulsion and steering
vessel and/or threat to the environment. - Vessel safety functions

(Quoted from No. TEC-1145)

Category III
System Examples of detailed machinery and system

Engine control system, Engine remote control system, Main boiler control system, CPP
Main propulsion systems
control system, Electric propulsion control system

Steering system control systems Steering system, Azimuth thruster

Electric power systems Generator engine control system, Electric power converter (for electric propulsion ship, etc.)

Fire detection and fighting system, Flooding detection and fighting system, Internal
Safety systems
communication system, System involved in operation of life saving appliances equipment

Other systems Dynamic positioning system, Drilling system


(Quoted from No. TEC-1145)

Category II
Cargo control system (e.g. cargo control console, cargo valve remote control system, cargo
Liquid cargo transfer control machinery emergency shut-down system),
systems Reliquefaction system, Inert gas generator (including nitrogen generator), Oil discharge
monitoring and control system

Fuel oil treatment systems Viscosity control system, Fuel oil purifier

Stabilization and
Fin stabilizer, Jetfoil
ride control systems

Alarm and monitoring systems


Engine alarm and monitoring system (including data logger)
for propulsion systems

Ballast transfer valve remote control system, Oily water separator, Oil content meter, Waste
Other systems oil incinerator, Sewage treatment plant, Aux. boiler control system, Ballast water treatment
system, SOx/NOx scrubber, NOx exhaust gas recirculation system

(Quoted from No. TEC-1145)

-6-
JAPAN P& I CLUB

It is defined that the responsibility for cyber security countermeasures of each computer system is down to the supplier
of each computer system. However, in the event of networking systems, the system integrator will be responsible
because there will be new risks, which were not taken into account when operating a system as a single unit.

The role of the shipowner and ship management company is to keep receiving necessary information, such as a list of
equipment that uses computers and risk assessment results etc. from the shipyard and system integrator; this is all that
is required of them.

However, with respect to the revision of the SMS in the future (cyber security countermeasures), the concept “System
integrator bears a certain amount of the responsibility” will play a key role. Regarding the onboard PC for duty
use, loading computer, V-SAT, FBB and so on, which are classified into Class Category I, it will be necessary for a
shipowner or ship management company to implement a risk assessment as a cyber security countermeasure.

3 - 3 Types of cyber risk

Although external factors such as unauthorized access and system hacking are mainly the focus when it comes to
cyber risk, it will be important to consider reviewing internal factors, such as the existence of operation mistakes and
general system failure.

Types of cyber risk

External factors Internal factors

General
Viruses
System failure
Unauthorized
zzz...
access

Social
Operation
Engineering Abuse
mistake

-7-
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

3 - 4 How to make a plan for cyber security countermeasures

❶ To identify the IT systems After identifying the IT systems installed on the ship, list them up.

Captain/Bridge PC
- E-mail software
- Nautical chart correction software
V-Sat / FBB
- Weather information software

Cargo Control Office PC


- Loading Computer program
- Stowage Plan Software Engine Control Office PC
- PMS program
- Fuel Management program


For each listed-up IT system, risk assessment is to be implemented by exam-
Implementation of risk ining the possible outcomes of a cyber attack (damage), frequency and current
assessment management method.

Table 4 Examples of risk assessment

 E-mail communication

No. Scenario Possibility Frequency Damage Evaluation Countermeasures Due date

Malfunction of e-mail ① Additional SMS


software infected by a Additional counter- training
1
virus from a crew mem- Middle Middle Middle measure is required ② Arrangement of a
Dec., 2018
ber’s personal USB back-up PC
Dispatch a technician
High cost of communica-
Additional counter- to the next port of call
2 tions fee because firewall Middle High Middle measure is required and install the FW and
Dec., 2018
is not installed
set up a filter in the FBB
Although a certain
Crew’s personal PC
amount of risk may be
that has been directly
3
connected for the use of Low Low Middle Risk tolerance tolerated, this can be N/A
further mitigated by
sending emails etc.
setting up the FBB filter
Malfunction of satellite
4
and land earth station Low Low Middle Risk tolerance N/A N/A

5 Continued...

The above is one example, because risk assessment and the SMS can differ depending on the crew structure, sea area for shipping operation, ship
type and management company.

-8-
JAPAN P& I CLUB

❸ Establishment of necessary
countermeasures
As a result of risk assessment, additional
countermeasures are to be planned,
implemented and operated, if necessary.

❻ Review and improvement ❹ and management of incidents


Implementation, operation

Following a statistical analysis, review as to Check the operational status of additional


whether the additional countermeasures are countermeasures and verify that there are no
effective, and if the additional countermeasures incompatibilities or defects using reports of incidents
are insufficient or if a new risk was reported, the and near misses from the ship, or an ISM/ISPS
risk assessment is to be implemented again. internal audit carried out by a superintendent (SI).

❺ Incident statistical analysis


Companies are to carry out the statistical
analysis based on the reports of incidents
and near misses from the ship, and the results
reported from the ISM/ISPS internal audit.

❶・・・・・・・・・・ Identify the IT systems on the ship in order to list them up.
❷ ❸・ ・・・ In the same way that dangerous work and hazardous areas designated on the ship are operated using the current
SMS, identify the onboard IT systems and implement a risk assessment while examining the possible outcome
of a cyber attack (damage), frequency of and current management method, and carry out a countermeasure,
if necessary. When confronted with a cyber risk, it is also necessary to consider trends in the IT field, types and
versions of systems and equipment, and so on.

❹・・・・・・・・・・ Check the operational status of additional countermeasures and verify as to whether there were no incompatibilities
or defects using reports of incidents and near misses from the ship, or an ISM internal audit carried out by a SI.

❺ ❻・・・・ Companies are to implement the statistical analysis based on the reports of incidents and near misses from
the ship, and the results reported from the ISM internal audit. Following the results of the statistical analysis,
review (management review) as to whether the additional countermeasures were effective, and if the additional
countermeasures were insufficient or if any new risks were reported, a risk assessment is to be implemented
again, in the same way that the operation would be carried out with the existing SMS, and the necessary
countermeasures are to be examined.

Regarding the reporting of incidents and near misses, the following examples can be said to be occurring recently:
A crew member inserted a USB memory stick which is not permitted by the company, into their work PC, or he/she
downloaded non-permitted software or a programme onto the onboard PC.
In addition, in order to receive visitors (external factors of cyber risk), not dissimilar to that of the SMS, it could be
necessary to review the SSP, also, as an unspecified number of visitors and dock workers will get on board, especially
at the port of call, and multi-purpose offshore support vessels and research vessels carrying a large number of
researchers and workers may embark.

-9-
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

§4 Selecting designated IT personnel

We believe that it will be desirable to appoint an IT designated person when it comes to drawing up and implementing
cyber security countermeasures that can be incorporated into the SMS. In the future, when countermeasures in a state
of emergency and the introduction of systems maintenance on board a ship are required, the role of the IT Manager
and the importance of this role will become more essential. In addition, it will be important to have a system in place
that allows for consultation to be carried out with an external ship IT system expert.

President
Emergency Response Team

Designated Person Ship Management Committee

Auditing Team

Crew Department
IT Manager
Marine Department Technical Department

Master IT consultant

- 10 -
JAPAN P& I CLUB

§5 Establish an IT standard in your organization

The establishment of an IT standard will allow for the smooth integration of operation and management (maintenance
etc.) if your organization is managing a large fleet of ships. With an IT standard in place, it will be much easier to deal
with any problems that arise, compared to not having established one.

FBB V-SAT

Back up HDD

Firewall / Router

L2 switch

LAN for private use LAN for business use

Onboard WiFi
ECDIS PC NAS
Access Point

Fig. 5 Construction example of ship's LAN

It is important to organize the specification, software and purpose of each onboard PC. For reference, it will be useful
if a substitute PC is available in case a PC breaks down or new software is added.

- 11 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

Record standard design of onboard PC!

Record for IT Standard Design

Standard type:
Date of Record:
IT Manager:
Designated Person:

This IT Standard will be value from :

I. Client PC Conditions Remark


(1) Hardware
Number of PCs
Type (Laptop PC/Desktop PC)
CPU
Memory
HDD
(2) Software Basic Software
OS
MS-OFFICE (version)
MS-OFFICE (Applications)
Acrobat Reader
AntiVirus Software
(3) Software Application Software Applications Suppliers

(4) Network Diagram Detail of PC setting


Detail of PC setting (Refer to the second sheet)
II. Peripheral Device
(1) Printer
Laser Printer
* Number of them
* Single or Multiple function
* Black/White or Color
Inkjet Printer
* Number of them
* Single or Multiple Function
* Black/White or Color
(2) Scanner
* Number of them
* Flatbed/Stand
(3) NAS set
* Model
III. Network
(1) Router
Type of Router
Supplier

(2) Sub Network


Purpose of Sub Network
(3) Wifi Access Point
Number of Wifi Access Point
(4) Network Diagram
Network Diagram (Refer to the third sheet)

Table 6 Record for IT Standard Design

- 12 -
JAPAN P& I CLUB

§6 Implementing an IT standard risk assessment

Regarding the IT standard (ship's LAN/onboard PC specification), risk assessment is to be implemented following
the procedure that was established in the introduction of this guide “3-4 How to make a plan for cyber security
countermeasures”.
Please note that systems that have already been risk assessed, IT systems that do not directly interfere with work being
carried out even when a system failure occurs, stand-alone use computers etc. in Class Category II and III can be
excluded from the risk assessment.

§7 S
 MS manual to include IT control documents

Having implemented a risk assessment and incorporation of the IT control documents into SMS manual, it is
recommendable that a ship and shore joint drill that simulates a severe IT incident be implemented, even if only once.
It would be a good opportunity to review as to whether the manual and instructions for cyber security countermeasures
which were established in the SMS manual work effectively, and as to whether both personnel on shore and crew on
the ship are familiar with the new manual and so on.

- 13 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

§8 Conclusion

It is hoped that if this Loss Prevention Bulletin will be put to


good use and that it may assist you in your establishment of
cyber security countermeasures.
<Remarks> The documents and contents in this bulletin
were compiled with the co-operation of ORCA CO., LTD.
(Http://www.orcajpn.co.jp/index.html).

Text and forms provided by ORCA CO., LTD.

Following test and forms are available on our Club website

Text and forms provided by ORCA CO., LTD.


1. Regulation for the Organization of the Safety Management System MN-02-00…………………………… 15
2. Chart of Organization for the Safety Management System MN-02-00A……………………………………… 16
3. Regulation for management of IT systems MN-20-00………………………………………………………… 17
4. Procedure for management of IT systems MN-20-01………………………………………………………… 22
5. Guideline for IT system integration MN-20-01A… …………………………………………………………… 27
6. Procedure for Cyber Risk Management MN-20-02… ………………………………………………………… 31
7. Record for IT Standard design SM0750………………………………………………………………………… 33
8. List of the IT Systems SM0751… ……………………………………………………………………………… 36
9. Records for Risk Assessment of the IT Systems SM0752… ………………………………………………… 37

⿙⿙Our club’s original poster … …………………………………………………………………………………… 38

Reference  ICS Bridge Procedure Guide Fifth Edition

- 14 -
JAPAN P& I CLUB

1. Regulation for the Organization of the Safety Management System MN-02-00

ORCA-MN-02-00
Revision: 1
Page: 1 of 1
Date: 01 Feb,2018

SMS Document No.: ORCA-MN-02-00 Chapter: 2


Issued by: The Designated Person Approved by: The President
Title: Regulation for the Organization of the Safety Management System

1. Purpose

This regulation is to define the responsibilities and authorities of Departments and


personnel implementing the SMS. It also clarifies the reciprocal relationship between
them in order to ensure that the Company's management activities comply with the
regulations of safety operation and environmental protection.

(snipped)

4.5 The IT Manager


4.5.1 The IT Manager is responsible for the following jobs;
(1) To ensure the proper operations of IT systems onboard ships and ashore;
(2) To watch, assess, and assist to response to IT related incidents;
(3) To proceed necessary training and education related to IT systems;
(4) To control data related to IT systems;
(5) To catch up cyber risks in IT fields;
4.5.2 The Company may contract with outside IT expert or consultant to support IT
matters, if so required.

(snipped)

ORCA CO., LTD.

- 15 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

2. Chart of Organization for the Safety Management System MN-02-00A


ORCA-MN-02-00A
Revision: 0
ORCA-MN-02-00A Page: 1 of 1
Date:001 Feb,2018
Revision:
Page: 1 of 1
Date: 01 Feb,2018

SMS Document No.: ORCA-MN-02-00A


SMS Document No.: ORCA-MN-02-00A
Chapter:
Chapter: 2
2
Issued by: Theby:
Issued Designated Person
The Designated Person Approved by:
Approved by: The
The President
President
Title: Chart
Title:ofChart
Organization for the
of Organization Safety
for the SafetyManagement System
Management System

President
President

Emerg. Response Team

Emerg. Response Team


Designated Person Ship Management
Committee

Ship Management
Designated Person
Committee
Auditing Team

Auditing Team
Head- Crew Department Head- Ship Management Dept. IT Manager

IT consultant
Head- Crew Department
Manning Company Head- Ship Management Dept. IT Manager
Master

IT consultant
Manning Company
Master
Chief Officer Chief Engineer Radio Officer Shipboard
(Radio & Management
(Deck dept.) (Engine dept.) Pursers) Committee

Chief Officer Chief Engineer Radio Officer Shipboard


(Radio & Management
(Deck dept.) (Engine dept.) Pursers) Committee

ORCA CO., LTD.

- 16 -
JAPAN P& I CLUB

3. Regulation for management of IT systems MN-20-00

ORCA-MN-20-00
Revision: 0
Page: 1 of 5
Date: 01 Feb. 2018

SMS Document No.: ORCA-MN-20-00 Chapter: 20


Issued by: The Designated Person Approved by: The President
Title: Regulation for management of IT systems

1. Purpose

This regulation is prepared to specify the arrangement and management of IT systems in


the Company and onboard ships for the proper implementation of SMS, including to
response to possible cyber risks.

2. Application

This regulation is applicable to the Company and all vessels under management of the
Company.

3. Reference regulations

SOLAS XI-2
MSC-FAL-1/Circ. 3

4. Definition

4.1 IT system
“IT system” is a computer-based system used for all kind of operations. The
system can be total packaged equipment or install based software for PC. Any
device, equipment or services based on computer are defined as a part of "IT
System".
4.2 Cyber-risk
“Cyber-risk” is a potential risk to lead operation failure of the IT systems, which
will cause financial loss, disruption or damage to the reputation of an
organization. Cyber-risk includes external factors (such as computer virus,
Trojans, or attack over network, etc.) and internal factors (malfunction, miss-
operation, or system bug, etc.).
4.3 IT incident
“IT incident” is an occurrence, which actually or potentially results in adverse
consequences to IT systems, includes all deficiencies and non-conformities
involving to the IT systems.

ORCA CO., LTD.

- 17 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-00
Revision: 0
Page: 2 of 5
Date: 01 Feb. 2018

4.4 Cyber risk management


“Cyber risk management” is the process of identifying, analyzing, assessing, and
communicating a cyber related risk and accepting, avoiding, transferring, or
mitigating it to an acceptable level; taking into consideration the costs and
benefits taken by the Company.

5. Requirements

5.1 Design of IT standard


For a smooth and effective implementation of the SMS, the Company shall set-
up an IT Standard, and, accordingly, construct IT Systems in the Company and
on-board ships under management of the Company. IT Standard is to be
recorded on the “Records for IT Standard Design” (ORCA-SM-07-50), and to be
annually reviewed for any improvement by the IT Manager. For details, refer to
the “Procedure for Management of IT Systems” (ORCA-MN-20-01).

5.2 Operation of IT systems


Under the direction of the Designated Person and the Head of the
Shipmanagement Department, the IT Manager must integrate the specified IT
Systems and network systems properly and supervise and direct the relevant
personnel to operate IT systems in accordance with IT Standard or makers”
instructions.

5.3 Identification of IT systems

5.3.1 The IT manager should identify all IT systems onboard and ashore using the
“List of IT Systems” (ORCA-SM-07-51).
5.3.2 The IT manager should process the risk assessment regarding cyber-risk for each
IT systems and prepare for countermeasure if so required.
5.3.3 During the risk assessment, if a part of the IT systems had already assessed in
the IT standard, the part of risk assessment can be omitted.
5.3.4 In case of addition, replacement, or abolition of the IT system had been taken,
the IT manager must re-process risk assessment to the part of modification.

5.4 Maintenance of IT systems

ORCA CO., LTD.

- 18 -
JAPAN P& I CLUB

ORCA-MN-20-00
Revision: 0
Page: 3 of 5
Date: 01 Feb. 2018

In order to ensure the proper operation of IT systems, the IT Manager shall set
up a maintenance plan (on the OMPS software) for the periodic maintenance of
IT systems, including its important elements as well as associated software. The
maintenance plan should include the following factors:
(1) Maintenance operation designated by each IT system vender.
(2) Minor software update.
(3) Backup operation of data.
(4) Condition check of each IT systems.
Maintenance of the IT systems should be processed in reference to the
“Regulation for Maintenance of Hull, Machinery and Equipment”

5.5 Hardware Replacement of IT systems


5.5.1 Due to service life, hardware of the IT systems required replacement.
5.5.2 The IT manager should plan the hardware replacement considering following
factor;
(1) Recommendation of the hardware vender
(2) Condition report of the IT systems
(3) Improvement of new hardware tolerance for cyber-risk
5.5.3 Plan for replacement should include following operation;
(1) Replacement of the client PC due to deterioration
(2) Replacement of the peripherals due to deterioration
(3) Replacement of the hardware which has newer countermeasure to handle
cyber-risks.
(4) Replacement of the hardware which considered being required for
appropriate operation of the IT systems.

5.6 Version control for firmware or software of IT Systems.

5.6.1 The IT manager should control version tables of firmware or software of the IT
systems.
5.6.2 If any update version has been released, the update should be applied as possible.
5.6.3 However, major update might affect to compatibility or connectivity among
other IT systems. In this case, sufficient verification and risk assessment must be
done by the IT manager before applying the update.
5.6.4 The IT manager should judge if the update is major or minor appropriately.

ORCA CO., LTD.

- 19 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-00
Revision: 0
Page: 4 of 5
Date: 01 Feb. 2018

5.7 Handling of incidents of IT systems


5.7.1 The IT manager should handle and solve incidents in relation to the IT system
onboard and ashore.
5.7.2 The IT manager should record the incidents for future analyzing, to improve
tolerance for cyber-risk.
5.7.3 If the incident is considered as critical, the IT manager must report this to the
Designated person according to “Regulation for emergency preparedness” .
5.7.4 After solution of the critical incident, the IT manager must proceed risk
investigation for recurrence prevention.
5.7.5 The “Procedure for Cyber Risk Management” (ORCA-MN-20-02) must also be
referred to.

5.8 Education and training regarding to the operation of IT systems.


5.8.1 The IT manager should ensure that all personnel involved in the Company's
SMS have an adequate understanding of the IT systems and cyber-risks.
5.8.2 The IT manager should plan appropriate education or training in relation to the
operation of the IT systems.
5.8.3 The education or training plan should be processed in reference to “Regulation
for Education and Training” .
5.8.4 The IT manager should timely release a newly appeared cyber-risk to the
relevant departments and vessels for prevention purpose.

5.9 Data Management of IT systems.


5.9.1 The IT manager should properly manage the data which is operated in the IT
systems.
5.9.2 Regarding the data management, following factor should be considered;
(1) Availability the data can be used in proper timing.
(2) Integrity to prevent data loss or falsification
(3) Confidentiality the data will not be leaked to any unauthorized party.
5.9.3 The IT manager should clarify about ownership of intellectual property for the
data.
5.9.4 In case of transfer of management of a ship, the IT manager should correct or
delete the data in reference to “List of the IT systems” (ORCA-SM-07-51).

5.10 Monitoring of unknown cyber-risks.


5.10.1 The IT manager should try to find out new unknown cyber-risks.

ORCA CO., LTD.

- 20 -
JAPAN P& I CLUB

ORCA-MN-20-00
Revision: 0
Page: 5 of 5
Date: 01 Feb. 2018

5.10.2 Master or each Department of the Company must inform the IT manager for any
newly identified cyber-risk.

5.11 Management review regarding to IT systems


5.11.1 The IT manager should provide following information to the safety management
committee during management review;
(1) Analyze report of the IT incidents
(2) Newly found cyber-risk and risk assessment report
(3) Trend information of IT fields
(4) Update information of software and hardware.
(5) Revision plan of IT standard with risk assessment
(6) Revision plan of IT systems list with risk assessment.
5.11.2 The Designated Person should investigate this information and review the IT
management in reference to “Regulation for Internal Audits and Management
Reviews” (ORCA-MN-11-00).

5.12 Contract with IT consultant or IT expert


5.12.1 Operation of IT system which connected to Internet using TCP/IP, requires high
knowledge and experience regarding IT.
5.12.2 In order to support the IT manager, the Company may contract with external IT
consultant or IT expert.

6. Applicable procedures

Procedure for Management of IT Systems (ORCA-MN-20-01)


Procedure for Cyber Risk Management (ORCA-MN-20-02)

7. Applicable records:

The Company and the ship:


Records for IT Standard Design (ORCA-SM-07-50)
List of IT Systems (ORCA-SM-07-51)
Records for Risk Assessment of IT Systems (ORCA-SM-07-52)
Maintenance Plan for Hull, Machinery and Equipment

ORCA CO., LTD.

- 21 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

4. Procedure for management of IT systems MN-20-01

ORCA-MN-20-01
Revision: 0
Page: 1 of 5
Date: 01 Feb. 2018

SMS Document No.: ORCA-MN-20-01 Section: 20-1


Issued by: The Designated Person Approved by: The President
Title: Procedure for Management of IT Systems

1. Area of application

This procedure defines the guidance for the management of IT systems onboard and
ashore and apply to the Company and vessels under the management of the Company

2. References

ORCA-MN-20-00 Regulation for Management of IT systems

3. Procedure to setup IT Standard

3.1 The IT manager should design IT Standard using “Record for IT Standard
Design” (ORCA-SM-07-50) to standardize the IT system integration.
3.2 In order to prevent any problem in connection of software and hardware,
following factor should be verified;
(1) Compatibility
(2) Convertibility
(3) Conflict
(4) System response speed
3.3 The IT manager should prepare IT Standard for vessel and company.
3.4 The IT manager should categorize the IT system as following;
Company Effects
Category
A Those systems, failure of which will not directly affect to
commercial shipping operation.
B Those systems, failure of which could eventually impact to
commercial shipping operation.
C Those systems, failure of which could immediately cause an
impact to commercial shipping operation.
3.5 Regarding Category B and C, The IT manager should prepare a specific measure
to ensure those systems working continuously.

ORCA CO., LTD.

- 22 -
JAPAN P& I CLUB

ORCA-MN-20-01
Revision: 0
Page: 2 of 5
Date: 01 Feb. 2018

3.6 The ship manager should also categorize the IT system defined by NK TEC-
1145 as followings;
Class Effects
Category
I Those systems, failure of which will not lead to dangerous
situations for human safety, safety of the vessel and/or threat to
the environment.
II Those systems, failure of which could eventually lead to
dangerous situations for human safety, safety of the vessel
and/or threat to the environment.
III Those systems, failure of which could immediately lead to
dangerous situations for human safety, safety of the vessel
and/or threat to the environment.
3.7 The ship manager should process risk assessment regarding IT standard.

4. Procedure for risk assessment of IT SYSTEM

4.1 The IT manager should process risk assessment regarding identified risks on IT
systems using the “Record for Risk Assessment of IT Systems” (ORCA-SM-07-
52).
4.2 If any connection had made among multiple IT systems, risk of the connection
should be also verified.
4.3 Following factors should be assessed for each risk;
(1) Possibility
(2) Frequency
(3) Damage
4.4 In conclusion of the assessment, following option should be selected;
(1) Accept the risk
(2) Measures required
(3) To be re-evaluate later
4.5 If any countermeasure required, the IT manager should plan a measure and
process it with approval of the Designated Person.
4.6 As risk assessment requires highly knowledge and experience of IT, it is
preferable to have an advice from IT consultant or IT expert.

5. Procedure for review of IT Standard

ORCA CO., LTD.

- 23 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-01
Revision: 0
Page: 3 of 5
Date: 01 Feb. 2018

5.1 The IT manager should review the IT standard annually.


5.2 If any modification such as revision, addition, deletion has been made in IT
standard, the IT manager must process risk assessment on such modification.
5.3 Even if no modification had been made, the IT manager still has to process risk
assessment considering following factor;
(1) Change of shipping operation environment and requirement
(2) Improvement of IT technology
(3) Trend of new cyber-risks
5.4 Update of IT Standard must be submitted to the Designated Person for approval.
5.5 If update of the IT Standard had been approved, the IT manager should prepare a
plan to update each IT system of vessel and shore side.

6. Preparation of IT systems in newly management vessels.

6.1 The IT manager shall refer to the IT standard and integrate IT systems onboard
the ship with reference to the “Guideline for IT System Integration” (ORCA-
MN-20-01A) and record the same on the “list of IT Systems” (ORCA-SM-07-
51).
6.2 The IT manager should process risk assessment for each IT systems using
“Record for Risk Assessment of IT Systems” (ORCA-SM-07-52).
6.3 In this assessment, if the IT system is already assessed in IT Standard,
assessment of this part can be omitted.
6.4 Also, if the IT system is categorized as Category II or III in NK TEC-1145, and
the system is operated as standalone, assessment of this part can be omitted.
These systems should be assessed by the system vender.
6.5 The IT manager should prepare a maintenance plan including following tasks;
(1) Maintenance operation which instructed by the system vender.
(2) Minor update of software/firmware which approved by the IT manager
(3) Backup of the data
(4) Condition check
6.6 These preparations should be approved by the Designated Person.

7. Procedure for handling of IT systems by the termination of vessel management.

ORCA CO., LTD.

- 24 -
JAPAN P& I CLUB

ORCA-MN-20-01
Revision: 0
Page: 4 of 5
Date: 01 Feb. 2018

7.1 The IT manager should correct or delete the data of every IT systems onboard,
referring “List of IT Systems” (ORCA-SM-07-51).

8. Procedure for modification of IT system

8.1 In case of IT system modification such as addition, replacement, or abolition is


planned, the IT manager should verify following factors;
(1) Compatibility
(2) Convertibility
(3) Conflict
8.2 The IT manager should also process risk assessment for the new connection of
IT systems.
8.3 If any risk or problem has been found the IT manager should prepare a
countermeasure to operate new system integration or postpone the modification.
8.4 The conclusion should be approved by the Designated Person.

9. Procedure for handling IT incident

9.1 The IT manager should handle IT incident occurred both onboard and ashore.
9.2 In case of following situation, the IT manager must report the occurrence to the
Designated Person as critical incident.
(1) The incident can directly affect to the vessel’s safety navigation.
(2) Or, the incident can lead to commercial damage to outside of the company.
(3) Or, delay of the solution may lead to situation (1) or (2).
9.3 In case of critical incident, the Designated Person must setup Emergency
Response Team to handle the situation in reference of “Regulation of
Emergency Preparedness” (ORCA-MN-10-00).
9.4 The Designated Person can contact IT consultant or IT expert for advice, if so
required.
9.5 The “Procedure for Cyber Risk Management” (ORCA-MN-20-02) must also to
be referred to.

10. Relevant forms and information

Guideline for IT System Integration (ORCA-MN-20-01A)


Procedure for Cyber Risk Management (ORCA-MN-20-02)

ORCA CO., LTD.

- 25 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-01
Revision: 0
Page: 5 of 5
Date: 01 Feb. 2018

Records for IT Standard Design (ORCA-SM-07-50)


List of IT Systems (ORCA-SM-07-51)
Records for Risk Assessment of IT Systems (ORCA-SM-07-52)
Maintenance Plan for Hull, Machinery and Equipment (the OMPS)

ORCA CO., LTD.

- 26 -
JAPAN P& I CLUB

5. Guideline for IT system integration MN-20-01A

ORCA-MN-20-01A
Revision: 0
Page: 1 of 4
Date: 01 Feb. 2018

Appendix
Guideline for IT system integration

Client PC
(1) Following points should be considered for selection of client PC model.
(a) Sufficient CPU power, memory, HDD space to operate the IT systems.
Especially, security software requires these resources.
(b) PC model which has enough reliability to operate onboard.
(2) Language model might affect to the IT systems. The IT manager must verify it if
PCs are supplied from different countries.

OS
(1) In order to apply necessary security update, “auto update function” should be ON as
possible.
(2) However, major updating of OS might affect to the other IT systems or peripherals.
If the IT manager decides to update the OS’s version, sufficient verification and risk
assessment must be taken.

Basic software
(1) “Basic software” is software which acts as system requirements of each IT systems,
such as MS-Office, PDF reader, etc.
(2) Major update of basic software might affect to related IT systems. So if the IT
manager decides to update the version of basic software, sufficient verification and
risk assessment must be taken.

Application software
(1) All application software should be verified in IT standard environment by the IT
manager before installation.
(2) If the application software has a communication function, detail of the function
(communication port, destination IP, etc.) must be clarified. If communication detail
of the software is not disclosed, the software shall not be adopted.
(3) Application software might have conflict to the other applications. In order to
prevent conflicts, the IT manager must proceed sufficient verification before
adoption.

ORCA CO., LTD.

- 27 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-01A
Revision: 0
Page: 2 of 4
Date: 01 Feb. 2018

Anti-virus software
(1) Anti-virus software (or any kind of security software) must be installed to all
operational official PCs.
(2) The IT manager should prepare an appropriate method to update definition files (or
pattern files) to keep Anti-virus software operational.
(3) Especially, in the vessel which has an ability to access to the Internet in the ocean,
“online updating function” is required.

Communication infrastructure
(1) In order to ensure communication reliability, it is preferred to have more than two
different kinds of communication infrastructure.
(2) The IT systems onboard are preferred to operate as “Open system” which will not be
affected by any specific communication infrastructure. The IT systems onboard
should be independent from communication.
(3) To control the latest cyber-risks, maintaining the version of OS and applications by
auto is very crucial. If the vessel has no ability to apply “auto updating” via satellite,
shore side communication such as 4G should be adapted.

Vessel Local Network (LAN)


(1) Vessel LAN should be designed to suit each IT systems can be operate
appropriately.
(2) Vessel LAN can be separated to multiple sub-network to control packet traffics.
(3) Following IT systems are preferred to be separated into sub-network due to their
traffic volume.
(a) Internet connection for crew welfare
(b) CCD monitoring camera system
(4) For any IT system identified its importance, the system should be placed into
independent sub-network to ensure traffic reliability.
(5) For crew welfare network, it is preferred to have Wi-Fi access points. So, crew can
connect his private device to them. In order to avoid network conflict, Ethernet
connection should not be provided to crew network.

Peripheral equipment
(1) The IT manager must clarify the detail of communication function of all LAN
connected peripheral equipment on board (port, destination IP, etc.). If the

ORCA CO., LTD.

- 28 -
JAPAN P& I CLUB

ORCA-MN-20-01A
Revision: 0
Page: 3 of 4
Date: 01 Feb. 2018

communication details are not disclosed, the equipment shall not be adopted.

Crew private device and private internet connection


(1) Most of cyber-risks are coming from crew private device and private connection
such as “rental 4G in port”.
(2) To bring this kind of situation under control, the IT manager must prepare
appropriate countermeasure such as;
(a) Train and educate crew to have adequate IT literacy.
(b) Identify the difference of management policy between official IT systems and
private devices.
(c) Prepare specific method to block this kind of cyber-risks which come from crew
private devices and Internet connections.
(3) One of the better solutions is to supply controlled Internet connection for crew
officially. Then, IT manager can arrange appropriate filters and sub-network settings
to prevent this kind of cyber-risks.

SNS or private E-mail access


(1) SNS or private E-mail access of crew might have security-risks.
(2) The IT manager should identify which onboard-information should be secured.
(3) The IT manager should train the crew for handling of secured information.

License compliance
(1) The IT manager must ensure that all software and hardware have appropriate
license.
(2) In order to avoid unknown cyber risks, following systems are prohibited.
(a) Illegal copy
(b) Pirated edition
(c) A hardware which have unauthorized modification.
(d) Any illegal network devices.

Network router
(1) It is preferred to have a network router independent from communication
infrastructure. So, the vessel LAN can be operated without dependency.
(2) Network router should have an ability to switch multiple communication
infrastructures.

ORCA CO., LTD.

- 29 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-01A
Revision: 0
Page: 4 of 4
Date: 01 Feb. 2018

(3) Network router should have a function to control internal network traffic.
(4) In order to avoid un-controlled traffic or cyber-attack from outside, un-necessary
port must be closed in filter settings.

ORCA CO., LTD.

- 30 -
JAPAN P& I CLUB

6. Procedure for Cyber Risk Management MN-20-02

ORCA-MN-20-02
Revision: 0
Page: 1 of 2
Date: 01 Feb. 2018

SMS Document No.: ORCA-MN-20-02 Section: 20-2


Issued by: The Designated Person Approved by: The President
Title: Procedure for Cyber Risk Management

1. Area of application

This procedure defines the guidance for taking necessary measures to response to cyber
security incidents of IT systems apply to the Company and all ships under the
management of the Company.

2. References

ORCA-MN-20-00 Regulation for Management of IT systems

3. Authorities and responsibilities

3.1 The Head of the Shipmanagement Department, under the direction of the
Designated Person, is responsible for cyber risks management, including IT
systems, onboard ships and the shore-based Company.

3.2 The IT Manager is responsible for the smooth operation of IT systems and,
supervise, monitoring, and timely response to cyber incidents.

3.3 The Master onboard is responsible for the smooth operation of IT systems and,
supervise, monitoring, and report any deficiency, non-conformity or cyber
incident to the Company in accordance with the “Procedure for Management of
Deficiencies and Non-conformities” (ORCA-MN-13-01).

4. Procedure

4.1 Identify threats- The IT Manager, under the direction of the Head of the
Shipmanagement Department, and the Designated Person, is to take measures to
make all relevant personnel understand the external cyber security threats to the
ship and the Company and to understand the internal cyber security threat posed
by inappropriate use and lack of awareness.

4..2 Identify vulnerability- The IT Manager is to develop inventories the Company and
shipboard systems with direct or indirect communication links with referring to
the “List of IT Systems” (ORCA-SM-07-51) and understand the consequences of
a cyber security threat on these systems also understand the capabilities and
limitations of existing protection measures.

ORCA CO., LTD.

- 31 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

ORCA-MN-20-02
Revision: 0
Page: 2 of 2
Date: 01 Feb. 2018

4..3 Assess risk exposure- The IT Manager is to assess and determine the likelihood of
vulnerabilities being exploited by external threats, by inappropriate use, and the
security and safety impact of any individual or combination of vulnerabilities
being exploited. The form “Records for Risk Assessment of IT Systems” (ORCA-
SM-07-52) is to be applied.

4.4 Develop protection and detection measures- The IT Manager, under the direction
of the Head of the Shipmanagement Department, and the Designated Person, is to
take measures to the likelihood of vulnerabilities being exploited through
protection measures also to reduce the potential impact of a vulnerability being
exploited.

4.5 Establish contingency plans- The IT Manager shall develop a response plan to
reduce the impact of the treats under the approval and direction by the Designated
person in accordance with the “Procedure for Management of Deficiencies and
Non-conformities” (ORCA-MN-13-01).

4.6 Response to and recover from cyber security incidents- After recover cyber
security incidents by using the response plan, the IT Manager shall assess the
impact of the effectiveness of the response plan and re-assess threats and
vulnerabilities.

4.7 Investigating cyber incidents- The IT Manager, under the direction of the Head of
the Shipmanagement Department, and the Designated Person, is to investigate
cyber incidents in order to archive a better understanding of the potential cyber
risks, identification of lessons learned also updates to technical and procedural
measures to prevent a recurrence.

4.8 Response to cyber incidents of IT systems - The IT manager shall assess its
vulnerability and impact and give a response in accordance with the “Procedure
for Management of Deficiencies and Non-conformities” (ORCA-MN-13-01), and
coordinate with the makers of the operational technology system to ensure its
safety and security.

5. Relevant forms and information

Records for IT Standard Design (ORCA-SM-07-50)


List of IT Systems (ORCA-SM-07-51)
Records for Risk Assessment of IT Systems (ORCA-SM-07-52)

ORCA CO., LTD.

- 32 -
JAPAN P& I CLUB

7. Record for IT Standard design SM0750

Record for IT Standard Design

Standard type:
Date of Record:
IT Manager:
Designated Person:

This IT Standard will be value from :

I. Client PC Conditions Remark


(1) Hardware
Number of PCs
Type (Laptop PC/Desktop PC)
CPU
Memory
HDD
(2) Software Basic Software
OS
MS-OFFICE (version)
MS-OFFICE (Applications)
Acrobat Reader
AntiVirus Software
(3) Software Application Software Applications Suppliers

(4) Network Diagram Detail of PC setting


Detail of PC setting (Refer to the second sheet)
II. Peripheral Device
(1) Printer
Laser Printer
* Number of them
* Single or Multiple function
* Black/White or Color
Inkjet Printer
* Number of them
* Single or Multiple Function
* Black/White or Color
(2) Scanner
* Number of them
* Flatbed/Stand
(3) NAS set
* Model
III. Network
(1) Router
Type of Router
Supplier

(2) Sub Network


Purpose of Sub Network
(3) Wifi Access Point
Number of Wifi Access Point
(4) Network Diagram
Network Diagram (Refer to the third sheet)

- 33 -
PC setting detail

PC01 PC02 PC03 PC04 PC05 PC06

Location or Main Usage


Location(Bridge, Master, etc.)
Type (Desktop, Laptop)
Main Usage(Mail, SMS-MAIN, SMS-SUB, Office Work)
E-mail Function(MAIN/SUB/NO)
Use LAN? (Y/N)
Softwares
ORCA SMS SYSTEM(MAIN/SUB/StandAlone/NO)
JAPAN P& I CLUB

MS-OFFICE
Peripherals
Laser Printer
Single or Multipul function, B/W or Color

- 34 -
Inkjet Printer
Single or Multipul function, B/W or Color
Scanner install
Install Driver/standard soft/quality adjust
Printer
Scanner
P&I Loss Prevention Bulletin
Network Diagram Plan

(Free Form)

- 35 -
JAPAN P& I CLUB
Vessel Computer Systems List

Vessel Name:

Date Report:

Reported by: Designated Person

1. Application Software
Category Version Data
System Name Supplier Remark
Class Company No. Update Property Backup Action
8. List of the IT Systems SM0751
JAPAN P& I CLUB

2. Network
Category Version Data
System Name Supplier Remark
Class Company No. Update Property Backup Action

- 36 -
3. Navigational Equipment
Category Version Data
System Name Supplier Remark
P&I Loss Prevention Bulletin

Class Company No. Update Property Backup Action


Vessel IT Risk Assessment Report

Vessel Name

Date Report

Report by Designated Person

ISSUE
Assessment
Date Found Description Evaluation Countermeasures Due Date Status
Possibility Frequency Damage

ISSUE
Assessment
Date Found Description Evaluation Countermeasures Due Date Status
Possibility Frequency Damage

- 37 -
9. Records for Risk Assessment of the IT Systems SM0752

ISSUE
Assessment
Date Found Description Evaluation Countermeasures Date Start Status
Possibility Frequency Damage
JAPAN P& I CLUB
JAPAN P& I CLUB
P&I Loss Prevention Bulletin
⿙⿙Our club’s original poster

Be aware of
Cyber Risk
CyberRisk0010101000000
0100101010010100010100
1000010010100101010110
0100010001001001010001
0010010010010010010100
1010001000010001001001
0100010010010010010010
0101001010001000010001
0010010100010010010010
Maritime Cyber Risk Management 0100100101001010001000
0100010011110CyberRisk
0000100001000000000100101010010100010100100001101010100101000010101
0000101100101010000100010010001000010000010010010010100010100101001
0000100001000000000100101010010100010100100001101010100101000010000

Remember Celestial Navigation?


In case of GPS (Global Positioning System) failure under navigation
with ECDIS, are you able to navigate by Celestial Navigation?

Over reliance on ECDIS should be avoided particularly


if detrimental to the keeping of a proper look-out

n Bridge

- 38 -
JAPAN P& I CLUB

Be aware of
Cyber Risk
CyberRisk0010101000000
0100101010010100010100
1000010010100101010110
0100010001001001010001
0010010010010010010100
1010001000010001001001
0100010010010010010010
0101001010001000010001
0010010100010010010010
Maritime Cyber Risk Management 0100100101001010001000
0100010011110CyberRisk
0000100001000000000100101010010100010100100001101010100101000010101
0000101100101010000100010010001000010000010010010010100010100101001
0000100001000000000100101010010100010100100001101010100101000010000

Is your GPS position data of


ECDIS truly correct?
All deck officers should be aware of importance of that;
- there’s a possibility that GPS data does not tell the correct position due to jamming devices.
- periodical check of cross track (XT) by visual, radar and radar overlay on ECDIS.
- re-check your Bridge Procedure.

ICS Bridge Procedure Guide say; ECDIS is an aid to safe navigation. ECDIS does not conduct safe
navigation or relieve the Master or OOW of their responsibilities for conducting safe navigation.

To be posted on Bridge

- 39 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

Be aware of
Cyber Risk
CyberRisk0010101000000
0100101010010100010100
1000010010100101010110
0100010001001001010001
0010010010010010010100
1010001000010001001001
0100010010010010010010
0101001010001000010001
0010010100010010010010
Maritime Cyber Risk Management 0100100101001010001000
0100010011110CyberRisk
0000100001000000000100101010010100010100100001101010100101000010101
0000101100101010000100010010001000010000010010010010100010100101001
0000100001000000000100101010010100010100100001101010100101000010000

Crew is not a System Integrator, is it?


Exchanging of LAN cables by onboard crew without owner’s permission,
caused malfunction of onboard computer based systems.

malfunction
IACS UR E22(Rev.1) specifies requirements related to composition and function of computer based
systems used for machinery systems such as monitoring systems.
3.3.2 Change management
The owner shall ensure that necessary procedures for software and hardware change management exist
on board, and that any software modification/upgrade are performed according to the procedure. All
changes to computer based systems in the operational phase shall be recorded and be traceable.

1 2 3 4

5 6 7 8

LAN 1 LAN 2 LAN 3 LAN 4 LAN 5 LAN 6 LAN 7 LAN 8 Power

All crew and visitors onboard shall strictly follow


the system security procedure.

- 40 -
JAPAN P& I CLUB

Be aware of
Cyber Risk
CyberRisk0010101000000
0100101010010100010100
1000010010100101010110
0100010001001001010001
0010010010010010010100
1010001000010001001001
0100010010010010010010
0101001010001000010001
0010010100010010010010
Maritime Cyber Risk Management 0100100101001010001000
0100010011110CyberRisk
0000100001000000000100101010010100010100100001101010100101000010101
0000101100101010000100010010001000010000010010010010100010100101001
0000100001000000000100101010010100010100100001101010100101000010000

Do (U)you (S)can and (B)lock


your ship's PC?

U Used only by authorised persons, in conjunction


with the periodical update of anti-virus software.

S Scan devices is to be activated whenever


a USB is used.

B Block ship's PC access at port and consider


the risks involved when using a USB.

It is a common root cause of infection of virus


ship’s PCs by USB connection.
All crew members should be fully aware of the risk.

To be posted on Public space, Bridge, Officers Office, Engine Control Room

- 41 -
JAPAN P& I CLUB
P&I Loss Prevention Bulletin

The author

Takehiko Hino / Manager


Loss Prevention and Ship Inspection Dept.
The Japan Ship Owners’ Mutual Protection & Indemnity Association

JAPAN P& I CLUB


Website http://www.piclub.or.jp

● Principal Office(Tokyo)
2-15-14, Nihonbashi-Ningyocho Chuoh-ku, Tokyo 103-0013, Japan
Tel:03-3662-7229 Fax:03-3662-7107
● Kobe Branch 6th Floor Shosen-Mitsui Bldg. 5, Kaigandori Chuoh-ku, Kobe, Hyogo 650-0024, Japan
Tel:078-321-6886 Fax:078-332-6519
● Fukuoka Branch 6th Floor Meiji-Dori Business Center 1-1, Shimokawabata-machi, Hakata-ku, Fukuoka 812-0027, Japan
Tel:092-272-1215 Fax:092-281-3317
● Imabari Branch 2-2-1, Kitahorai-cho, Imabari, Ehime 794-0028, Japan
Tel:0898-33-1117 Fax:0898-33-1251
● Singapore Branch 80 Robinson Road #14-01B SINGAPORE 068898
Tel:65-6224-6451 Fax:65-6224-1476
● Japan P&I Club (UK) Services Ltd  5th Floor, 38 Lombard Street, London EC3V 9BS U.K.
Tel:44-20-7929-3633 Fax:44-20-7929-7557

You might also like