11-Ground Floor Foundation Layout

The document contains remarks and notes for structural drawings of a building project. It states that all dimensions must be verified by the contractor before construction begins. It also notes that fixtures, inserts and other details required by other trades must be approved by the engineer before proceeding. Finally, it says that all dimensions are in centimeters and levels are in meters, and the drawings cannot be copied without authority from the engineering consultancy.

Uploaded by

Uzair Quraishi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views1 page

11-Ground Floor Foundation Layout

The document contains remarks and notes for structural drawings of a building project. It states that all dimensions must be verified by the contractor before construction begins. It also notes that fixtures, inserts and other details required by other trades must be approved by the engineer before proceeding. Finally, it says that all dimensions are in centimeters and levels are in meters, and the drawings cannot be copied without authority from the engineering consultancy.

Uploaded by

Uzair Quraishi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

REMARKS :

* THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURE AND OTHER
ENGINEERING DRAWINGS AND THE SPECIFICATION AND WITH SUCH OTHER WRITTEN

A D F J *
INSTRUCTIONS AS MAY BE ISSUED DURING THE COURSE OF CONTRACT .DISCREPANCIES SHALL BE
REFERRED TO THE ENGINEER FOR DECISION BEFORE PROCEEDING WITH THE WORK
ALL DIMENSIONS SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION AND
FABRICATION IS COMMENCED. ENGINEERING DRAWINGS SHALL NOT BE SCALE
STRUCTURAL NOTES :
1560 * THE STRUCTURAL DRAWINGS DO NOT NECESSARILY SHOW DETAILS OF FIXTURES, INSERTS,
SLEEVES OPENINGS ETC. REQUIRED BY THE VARIOUS TRADES ALL SUCH DETAILS MUST BE
1. FOUNDATION IS DESIGNED FOR BASEMENT & THREE FLOORS ONLY. APPROVED BY THE ENGINEER BEFORE PROCEEDING WITH THE CONSTRUCTION.
610 440 510 2. ASSUME S.B.C. TO BE 150 KN / m²
*
*
ALL DIMENSIONS ARE IN CENTIMETERS. ALL LEVELS ARE IN METERS .
THESE DRAWINGS ARE COPY PROTECTED AND MUST NOT BE RETAINED COPY OF USE WITHOUT
THE AUTHORITY OF THE ADDRESS ENGINEERING CONSULTANCY.

3. MINIMUM DEPTH OF FOUNDATION IS -180 CM. FROM LOWEST


20 mm 20 mm NATURAL GROUND LEVEL
EXPANSION EXPANSION 4. ALL KITCHENS, TOILETS & BATH ROOMS SLAB TO BE
SUNK BY 25 CM.
JOINT SHEET JOINT SHEET
5. ALL DIMENSIONS ARE FROM UNFINISHED FLOOR
LEVEL/ SURFACE.
90 440 90 6. ALL DIMENSIONS SHALL BE CHECKED AND VERIFIED AT SITE.
8 8

25

25
C1** NF1 C1** NF1 7. ALL DRAWINGS ARE INTERRELATED AND SHALL BE READ
CF6 C2

120
IN CONJUNCTION WITH ARCTURAL DWG. & OTHER
C2 RELEVANT DRAWINGS.
8. ANY DISCREPANCY FOUND IN THE DRAWING IS TO BE
IMMEDIATELY CLARIFIED WITH THE ENGINEER OR HIS
REPRESENTATIVE AT THE SITE BEFORE COMMENCEMENT

355
390

TB1 REFER LIFT

415
OF RELATED ITEMS OF WORK.
200 SECTION 200

TB1
9. ALL ELECTRICAL CONDUITS IN SLABS TO PASS OVER THE
C2** F1 DETAIL SLAB BOTTOM REINFORCEMENT.
10. NO ELECTRICAL CONDUITS ARE ALLOWED TO PASS THROUGH
C4 COLUMN AND NO OPENING SHOULD BE LEFT IN THE STRUCTURAL
CF4 MEMBERS WITHOUT WRITTEN PERMISSION OF THE ENGINEER.
7 7

90
C3 C2** 11. CONCRETE FOR STRUCTURAL MEMBERS SHOULD BE OF
60

160
140
6 6 GRADE M 30 UNLESS OTHERWISE SPECIFIED.

80
12. ALL REINFORCEMENTS SHALL BE HIGH YIELD HAVING
CHARACTERISTIC STRENGTH Fy- 460 N/mm2.
UNLESS OTHERWISE SPECIFIED.
220

250
C4 F6
1170

C3 F2 13. CONCRETE COVER TO REINFORCEMENT:-


FOUNDATION - 75mm.
125 125 COLUMN - 30 T0 40mm.
5 C2 5 BEAMS - 30mm., SLABS - 25mm.
CF5 14. BLOCK WORK BELOW EXTERNAL PLINTH BEAMS SHOULD BE
160
140

100
OF SOLID BLOCKS.
C4 15. IN ALL MASONRY WALLS CONTINUOUS LINTELS OF MINIMUM
4 110 110 4 SIZE 200x200 & MINIMUM REINFORCEMENT 4Y12 SHOULD BE
PROVIDED AT DOOR/WINDOW HEIGHT FOR THE FULL LENGTH
OF THE WALL PANEL.
180
200

16. UNDERGROUND PORTION OF COLUMNS TO HAVE EXTRA


COVER AS DETAILED.
C2 F1 C3 17. PROVIDE P.C.C. 100mm THICK WITH 100mm PROJECTION ALL
AROUND.
3 C2 F1 C2 F1
3 18. MINIMUM LAP LENGTHS SHOULD BE 50 Dia.
80

140

19. CONTINUE BOTTOM & TOP REINFORCEMENT OF SLABS AND


2 2 BEAMS UP TO THE SUPPORT
20. PROVIDE ADEQUATE CHAIRS TO SEPARATE TOP AND BOTTOM
80

REINFORCEMENT OF SLABS, CONTINUOUS FOOTINGS ETC.


1 1 21. IN BEAMS 200 WIDE, MAXIMUM NUMBER OF BARS IN ONE BOTTOM
LAYER IS 3. 20 Dia. PINS (SPACERS) SHOULD BE PROVIDED

A D F J SCHEDULE OF COLUMNS
**= COLUMN WIDTH 30 CM UPTO PLINTH
G.F COLUMN AND FOUNDATION LAYOUT (-1.8 M. LVL.) C1 C2 C3
THE ADDRESS ENGINEERING CONSULTANCY
P.O.BOX:895 , P.C:111 , Sultanate of Oman
Tel: 22025200, Email: [email protected]
www.theaddress-arch.com

SCHEDULE OF STRIP BEAMS SCHEDULE OF FOOTINGS FOR MUNICIPALITY USE


TOP STEEL P.C.C (mm) R.C.C (mm) MUNICIPALITY REGISTRATION NO. : 2018
SIZE BOTTOM STEEL
TYPE STIRRUPS REMARKS TYPE SHORT BARS LONG BARS REMARKS
(mm) STRAIGHT CURTAIL STRAIGHT EOC L B D L B D
4LEGGED
TB1 300 x 1000 6 Y 16 - 6 Y 18 - Y10 @ 150 C/C
4Y14F.B. F1 2900 2100 100 2700 1900 500 Y14 @ 150 C/C Y14 @ 150 C/C -
SIZE = 200 x 500mm SIZE = 200 x 500mm SIZE = 200 x 600mm
CLIENT :
F2 3000 2400 100 2800 2200 550 Y14 @ 150 C/C Y14 @ 150 C/C - Reinf. = 6Y 14 Reinf. = 8Y 14 Reinf. = 10Y 14 HUSSAM AL MARHOMY
Stirr. = Y8 @150 C/C Stirr. = Y8 @150 C/C Stirr. = Y8 @150 C/C
F3 3500 2600 100 3300 2400 600 Y14 @ 150 C/C Y14 @ 150 C/C - PROJECT :
F4 2600 2600 100 2400 2400 500 Y14 @ 150 C/C Y14 @ 150 C/C - PROPOSED VILLA
C4 C5 C6 AREA PLOT NO SQR. NO. LOCATION
F5 4000 3000 100 3800 2800 700 Y14 @ 150 C/C Y14 @ 150 C/C -
BOUSHAR
F6 3200 2700 100 3000 2500 600 Y14 @ 150 C/C Y14 @ 150 C/C - 594.00 SQM 1-05-05-1-01-259 PHASE
QURM
CF1 AS/DETAILS 100 AS/DETAILS 600 Y14 @ 150 C/C Y14 @ 150 C/C T&B
TITLE :
CF2 AS/DETAILS 100 AS/DETAILS 600 Y14 @ 150 C/C Y14 @ 150 C/C T&B
GROUND FLOOR COLUMN AND FOUNDATION
CF3 7200 5200 100 7000 5000 750 Y14 @ 150 C/C Y14 @ 150 C/C T&B LAYOUT (-1.8 M. LVL.)
CF4 4600 2400 100 4400 2200 700 Y14 @ 150 C/C Y14 @ 150 C/C T&B DESIGNED BY CHECKED BY SCALE
CF5 5000 2700 100 4800 2500 700 Y14 @ 150 C/C Y14 @ 150 C/C T&B ARCH.ALI ARCH.RAFEH 1:500
Y14 @ 150 C/C Y14 @ 150 C/C
SIZE = 200 x 600mm SIZE = 200 x 800mm SIZE = 40 mm DIA DRAWN BY APPROVED BY REV. NO.
CF6 6400 5400 100 6200 5200 700 T&B
Reinf. = 12Y 14 Reinf. = 14Y 14 Reinf. = 10Y 14 ----
Y14 @ 150 C/C Y14 @ 150 C/C WASEEM ENGINEER .ALI
NF1 2200 1900 100 2000 1700 500 T&B Stirr. = Y8 @150 C/C Stirr. = Y8 @150 C/C Stirr. = Y8 @150 C/C
SHEET NO. DATE DRAWING NO.
-11- 13-05-2019 J. 0094