0% found this document useful (0 votes)
61 views

Overview of ACS Dialogs and Functions HQ

This release note describes new features and changes to ACS790 software. New features include a Remote Tool Access application for connecting to web servers over cloud. Changes include performance improvements for reading/writing parameter sets and updating the .NET framework. Issues addressed include stretched plant diagrams and prioritizing read/write operations over error refreshes.

Uploaded by

najib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
61 views

Overview of ACS Dialogs and Functions HQ

This release note describes new features and changes to ACS790 software. New features include a Remote Tool Access application for connecting to web servers over cloud. Changes include performance improvements for reading/writing parameter sets and updating the .NET framework. Issues addressed include stretched plant diagrams and prioritizing read/write operations over error refreshes.

Uploaded by

najib
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

ACS CD 10.

20

Release note

Author: Pius Hausheer


Revision: 1, 15-May-2017

Unrestricted © Siemens Schweiz AG 2017 All rights reserved. siemens.com/acs790


New features

Remote Tool Access


With ACS790 installation, a new application named “Remote Tool
Access” also gets installed on PC.

Remote Tool Access facilitates connection to the web servers which are
connected over cloud using desktop tools like ACS, ETS, Web browser
etc.
For more details, see slide “Introduction to new features”

Unrestricted © Siemens Schweiz AG 2017 All rights reserved.


Page 2 / 7 Rev 1, 15-May-2017
Changes

§ Performance improvements
§ Read / Write Parameter set when multiple
connections are available
§ Error and Warning viewer refresh optimizations

§ Microsoft .NET framework


Updated to version 4.6.2 from 4.5.2

Unrestricted © Siemens Schweiz AG 2017 All rights reserved.


Page 3 / 7 Rev 1, 15-May-2017
Solved Issues

§ Print out of the Plant diagram was stretched


§ Read or write Parameter set has now a higher
priority than refreshing the bus errors for the Error
and warning viewer

Unrestricted © Siemens Schweiz AG 2017 All rights reserved.


Page 4 / 7 Rev 1, 15-May-2017
Introduction to new features

Remote Tool Access


With ACS790 installation, a new application
named “Remote Tool Access” also gets installed
on PC.

Remote Tool Access facilitates connection to


web servers which are connected over cloud.
Following picture shows how Remote Tool Access
accessing web server for tools like ACS, ETS,
Web browser etc.
1. The central units placed in different locations, are registered in the
Note: cloud.

For login to Remote Tool Access, user needs to 2. The Remote Tool Access application is installed on the same PC
where the Engineering tools e.g. ACS or ETS are installed.
have at least service level access for this site.
3. The Remote Tool Access and the central units are connected with
Internet via cloud.

Unrestricted © Siemens Schweiz AG 2017 All rights reserved.


Page 5 / 7 Rev 1, 15-May-2017
Introduction to new features / changes

Read / Write parameter set with multiple


connections
In the projects where there are
o Multiple Areas and Lines
o Central units in these Areas and Lines

In such projects, user will be presented with a


Connection Selection dialog when he tries to
Read / Write Parameter Set.

Read / Write Parameter set will be done in parallel


using the selected multiple connections.
The more communication units are connected,
the shorter is the time to complete the action.

Note: The improvement is there only if any ACS


connection is distributed over two or more couplers.
Unrestricted © Siemens Schweiz AG 2017 All rights reserved.
Page 6 / 7 Rev 1, 15-May-2017
Known Issues and workaround

§ If Microsoft Access Runtime 2016 x64 bit is present on the machine, trends are not getting created.

Workaround:
Uninstall Microsoft Access Runtime 2016 x64 bit and install
o Either Microsoft Access Runtime 2016 x32 bit or
o Any other Microsoft Access Runtime version which is lower than 2016, e.g.:
o Microsoft Access Runtime 2013 or
o Microsoft Access Runtime 2010