SNAP D-Series Racks

Features
Ideal for discrete control applications
Control directly or through an Opto 22 PC adapter card
Use panel or DIN-rail mounting
Modules snap into place

SNAP D-Series Racks


Description
SNAP D-series racks are designed for discrete control SNAP-D8M Rack
applications and can accommodate 4, 6, 8, or 12 SNAP 4-
channel digital modules. These racks use an industry-standard
50-pin header connector, which allows these racks to be used
in a variety of applications.
The logic side of the I/O circuitry can be controlled directly or
by using an Opto 22 PCIe-AC5 (PCI Express bus), PCI-AC5 (PCI
bus) or G4AC5 or AC5 (ISA bus) PC adapter card.
In addition, the 4-module-position SNAP-D4M can be used
with:
• A Raspberry Pi® and Opto 22’s Digital I/O Carrier Board for
Raspberry Pi (part number OPTO-P1-40P)
• Opto 22’s Classic brain boards, which use one of Opto 22’s
industry-standard protocols (mistic®, Optomux®, or Pamux®)
to control the I/O and communicate either serially or in
parallel
Field devices are wired directly to the top-mounted removable
connectors on the SNAP I/O modules. The module and rack
design allows modules to simply “snap” on and off the
mounting rack.
SNAP racks use a retention-rail locking system that holds
modules securely to the rack. Use two 4-40 by ½-inch
standard machine screws to secure each module in position.
Part Numbers
All SNAP racks offer panel mounting and the option of DIN-rail
mounting. SNAP racks use a single 5 VDC power source. Part Description
SNAP-D4M 4-module digital I/O rack
SNAP-D6M 6-module digital I/O rack
SNAP-D8M 8-module digital I/O rack
SNAP-D12M 12-module digital I/O rack
Classic digital brain board DIN rail
SNAP-CDBBDIN
adapter
DATA SHEET
Form 0777-161123

SNAP-FUSE1AB 1 amp fuse, 25-pack


SNAP PAC rack DIN-rail adapter
SNAP-TEX-DRC10
clip, 10-pack
Narrow end cap for SNAP PAC racks
SNAP-TEX-REC10N
DIN-rail assemblies, 10-pack

Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
© 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. 1
SNAP D-Series Racks
Specifications: SNAP-D4M (4 Module Position)

Power Schematic
Module Mating
Connector Pinout
(female)
SNAP D-Series Racks

Module holding screw


4-40 typical

Control Connector (50-pin male) Operating Requirements


Module Channel J1 Control 5 VDC ± 0.1 VDC @ 200 mA max.
Power Requirements
Position Position Connector (700 mA with brain board)

0 47 Operating Temperature Range 0° to 70°C

1 45 Relative Humidity 95%, non-condensing


0
2 43
3 41
4 39
Notes:
5 37
1. Even pins on control connectors are connected to 5V RTN.
1 2. Pin 1 of control connectors J1 and J2 is connected to +5V
6 35
through jumper JP1.
7 33
3. Pin 49 of control connectors J1 and J2 is connected to +5V
8 31 through jumper JP2.
9 29 4. For operation with PC adapter cards (PCIe-AC5, PCI-AC5,
2
10 27 AC5, or G4AC5), remove jumpers JP1 and JP2.
11 25 5. Odd numbered pins 3 through 15 of control connectors
are not used.
12 23
13 21
3
14 19
15 17
Form 0777-161123
DATA SHEET

PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
2 © 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
SNAP D-Series Racks
Specifications: SNAP-D6M (6 Module Position)

Power Schematic
Module Mating
Connector Pinout
(female)

SNAP D-Series Racks


Control Connector (50-pin male)
Module Channel J1 Control
Position Position Connector
Operating Requirements
0 47
Power Requirements 5 VDC ± 0.1 VDC @ 300 mA max.
1 45
0 Operating Temperature Range 0° to 70°C
2 43
Relative Humidity 95%, non-condensing
3 41
4 39
5 37
1 Notes:
6 35
1. Even pins on control connectors are connected to 5V RTN.
7 33
2. SNAP-D6M and SNAP-D12M are designed to interface with PC
8 31 adapter cards (PCIe-AC5, PCI-AC5, AC5, or G4AC5). They are not
9 29 compatible with brain boards, because there is no power to the
2
10 27 control connector.
11 25
3. Pin 49 - “no” connection.
12 23
13 21
3
14 19
15 17
16 15
17 13
4
18 11
19 9
DATA SHEET
Form 0777-161123

20 7
21 5
5
22 3
23 1

Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
© 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. 3
SNAP D-Series Racks
Specifications: SNAP-D8M (8 Module Position)

Power Schematic Module Mating


Connector Pinout
(female)
SNAP D-Series Racks

Control Connectors (50-pin male) Operating Requirements


Module Channel J1 Control Module Channel J2 Control 5 VDC ± 0.1 VDC
Power Requirements
Position Position Connector Position Position Connector @ 400 mA max.

0 47 16 47 Operating Tempera-
0° to 70°C
ture Range
1 45 17 45
0 4 95%, non-
2 43 18 43 Relative Humidity
condensing
3 41 19 41
4 39 20 39
5 37 21 37
Notes:
1 5 1. Even pins on control connectors are
6 35 22 35
connected to 5V RTN.
7 33 23 33
2. Pin 1 of control connectors J1 and J2 is
8 31 24 31 connected to +5V through jumper JP1.
9 29 25 29 3. Pin 49 of control connectors J1 and J2 is
2 6
10 27 26 27 connected to +5V through jumper JP2.
11 25 27 25 4. For operation with PC adapter cards
12 23 28 23
(PCIe-AC5, PCI-AC5, AC5, or G4AC5),
remove jumpers JP1 and JP2.
13 21 29 21
3 7 5. Odd numbered pins 3 through 15 of
14 19 30 19 control connectors are not used.
15 17 31 17
Form 0777-161123
DATA SHEET

PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
4 © 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
SNAP D-Series Racks
Specifications: SNAP-D12M (12 Module Position)

Power Schematic Module Mating


Connector Pinout
(female)

SNAP D-Series Racks


Control Connectors (50-pin male) Operating Requirements
Module Channel J1 Control Module Channel J2 Control 5 VDC ± 0.1 VDC
Power Requirements
Position Position Connector Position Position Connector @ 1200mA max.

0 47 0 47 Operating Tempera-
0° to 70°C
ture Range
1 45 1 45
0 6 95%, non-
2 43 2 43 Relative Humidity
condensing
3 41 3 41
4 39 4 39
5 37 5 37
Notes
1 7 1. Even pins on control connectors are
6 35 6 35
connected to 5V RTN.
7 33 7 33
2. SNAP-D6M and SNAP-D12M are
8 31 8 31 designed to interface with PC adapter
9 29 9 29 cards (PCIe-AC5, PCI-AC5, AC5, or
2 8
10 27 10 27 G4AC5). They are not compatible with
brain boards, because there is no
11 25 11 25
power to the control connector.
12 23 12 23
13 21 13 21
3 9
14 19 14 19
15 17 15 17
16 15 16 15
17 13 17 13
4 10
18 11 18 11
19 9 19 9
DATA SHEET
Form 0777-161123

20 7 20 7
21 5 21 5
5 11
22 3 22 3
23 1 23 1

Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
© 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. 5
SNAP D-Series Racks
Dimensional Drawing

Front View (when Mounted)—All Models


SNAP D-Series Racks

Overall Length Dimension (All Models)


Length Length
Part Numbers Description
(inches) (mm)

SNAP-D4M 4-module rack 4.19 106.43


SNAP-D6M 6-module rack 5.74 145.8
SNAP-D8M 8-module rack 7.74 196.6
SNAP-D12M 12-module rack 10.74 272.8
Form 0777-161123
DATA SHEET

PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
6 © 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
SNAP D-Series Racks
Dimensional Drawing

Right Side View (with Customer-supplied DIN-Rail Option)—All Models

SNAP D-Series Racks


DATA SHEET
Form 0777-161123

Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
© 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. 7
SNAP D-Series Racks
Dimensional Drawing
Typical Plain View of SNAP Mounting Extrusion—All Models
SNAP D-Series Racks

General Mounting Instructions


The SNAP rack assembly should be mounted horizontally, as
shown in diagram, if not using module hold-down screws.

Preferred Method: Template (product on site) Center-to-Center Length (All Models)


1. Use SNAP rack mounting extrusion as template.
Center-to- # of
2. Be sure to use drawing to determine required product Part
Description Center Length Center
Numbers
and option clearances. (inches) Positions

SNAP-D4M 4-module rack 1.98 2


Alternate Method: Prefabrication of Panels
(no product on site) SNAP-D6M 6-module rack 3.53 2

1. Mounting holes are in sets of two located on lower left SNAP-D8M 8-module rack 5.53 2
and upper right, with respect to a centerline (CL). SNAP-D12M 12-module rack 4.26 3
2. Using the drawing, determine CL1 mounting hole
positions. (CL1 is located on the left side of all SNAP rack
mounting extrusions.)
3. Use the center-to-center length specification table to
determine offset between centerlines and number of
Form 0777-161123
DATA SHEET

centerline positions for each model.


4. Repeat process for each centerline position.
5. Dimensions shown in drawing apply to all models.

PAGE Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com


SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
8 © 2009–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
More About Opto 22
Products Control programming includes both easy-to-learn flowcharts and
optional scripting. Commands are in plain English; variables and
Opto 22 develops and manufactures reliable, easy-to-use, open I/O point names are fully descriptive.
standards-based hardware and software products deployed
PAC Project Basic offers control and HMI tools and is free for
worldwide.
download on our website, www.opto22.com. PAC Project
Industrial automation, process control, building automation, Professional, available for separate purchase, adds one SoftPAC
industrial refrigeration, remote monitoring, data acquisition, software-based controller, OptoOPCServer, OptoDataLink,
Industrial Internet of Things (IIoT), and information technology options for controller redundancy or segmented networking, and
applications all rely on Opto 22. support for legacy Opto 22 serial mistic™ I/O units.
groov SNAP PAC Brains
Monitor and control your While SNAP PAC controllers provide central control and data
equipment from anywhere distribution, SNAP PAC brains provide distributed intelligence for
using your smartphone or I/O processing and communications. Brains offer analog, digital,
tablet with groov. Build your and serial functions, including thermocouple linearization, local
own mobile app easily—just PID loop control, watchdog, totalizing, and much more.
drag, drop, and tag. No SNAP I/O
programming or coding. Visit
I/O provides the local connection to sensors and equipment.
groov.com for more Opto 22 SNAP I/O offers 1 to 32 points of reliable I/O per module.
information and your free trial. Analog, digital, and serial modules are mixed on one mounting
rack and controlled by a SNAP PAC brain or rack-mounted PAC.
SNAP PAC System
Developer- and IIoT-ready, the SNAP PAC System connects
physical assets to databases and applications using open
Quality
standards. The SNAP PAC System consists of four integrated Founded in 1974, Opto 22 has established a worldwide
components: reputation for high-quality products. All are made in the U.S.A. at
• SNAP PAC controllers our manufacturing facility in Temecula, California.
• PAC Project™ Software Suite Because we test each product twice before it leaves
• SNAP PAC brains our factory, rather than only testing a sample of each
• SNAP I/O™ batch, we can guarantee most solid-state relays and
SNAP PAC Controllers optically isolated I/O modules for life.
SNAP PAC programmable
automation controllers handle a
Free Product Support
wide range of digital, analog, and Opto 22’s California-based Product Support Group
serial functions for data collection, offers free, comprehensive technical support for
remote monitoring, process control, Opto 22 products from engineers with decades of training and
and discrete and hybrid manufacturing. experience. Support is available in English and Spanish by phone
For IIoT applications and easier integration with company or email, Monday–Friday, 7 a.m. to 5 p.m. PST.
systems, standalone and rack-mounted SNAP PACs include a Additional support is always available on our website: how-to
built-in HTTP/HTTPS server and RESTful API (application videos, OptoKnowledgeBase, self-training guide, troubleshooting
program interface). The REST API gives you secure, direct access and user’s guides, and OptoForums.
to I/O and variable data using your choice of programming In addition, hands-on training is available for free at our Temecula,
languages. No middleware, protocol converters, drivers, or California headquarters, and you can register online.
gateways needed.
Based on open Ethernet and Internet Protocol (IP) standards, Purchasing Opto 22 Products
SNAP PACs make it easier to build or extend a system without the
expense and limitations of proprietary networks and protocols. Opto 22 products are sold directly and through a worldwide
network of distributors, partners, and system integrators.
PAC Project Software Suite For more information, contact Opto 22 headquarters at
Opto 22’s PAC Project Software Suite offers full-featured, cost- 800-321-6786 (toll-free in the U.S. and Canada) or 951-695-3000,
effective control programming, HMI (human machine interface), or visit our website at www.opto22.com.
OPC server, and database connectivity software.

www.opto22.com
www.opto22.com • Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • Form 1335-160810
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • [email protected] • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • [email protected]
© 2013–2016 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.