BERTScope Bit Error Rate Analyzer Quick Start User Manual RevisionA PDF
BERTScope Bit Error Rate Analyzer Quick Start User Manual RevisionA PDF
Tektronix BERTScope
Bit Error Rate Analyzers
BSA85C, BSA125C, BSA175C, BSA286CL
ZZZ
*P071286904*
071-2869-04
xx Tektronix BERTScope
Bit Error Rate Analyzers
BSA85C, BSA125C, BSA175C, BSA286CL
ZZZ
Revision A
www.tektronix.com
071-2869-04
Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are
protected by national copyright laws and international treaty provisions.
Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all
previously published material. Specifications and price change privileges reserved.
TEKTRONIX and TEK are registered trademarks of Tektronix, Inc.
Contacting Tektronix
Tektronix, Inc.
14150 SW Karl Braun Drive
P.O. Box 500
Beaverton, OR 97077
USA
Table of Contents
Important safety information . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . .. . iii
General safety summary.. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . iii
Service safety summary .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . v
Terms in this manual . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . vi
Symbols and terms on the product . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . vi
Compliance information .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . .. vii
EMC compliance . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. vii
Safety compliance. .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . viii
Environmental considerations .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . x
Preface .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . xi
Features and benefits .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . xi
Documentation . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. xii
Conventions used in this manual .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. xii
Introduction . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . xiii
Product description . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . xiii
Key specifications . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . xiv
Options .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . xiv
Installation.. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . .. . .. . .. . 1
Standard accessories .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 1
Optional accessories. .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 1
Site considerations .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . 2
Preventing ESD .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 2
Power on the instrument .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 3
Power off the instrument .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 4
Operation. .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 5
Front panel controls and connectors . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 5
Rear panel connectors . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . 8
Menu overview . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 10
Access system information .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 12
Applications . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 13
Example 1: Configure the Pattern Generator . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 13
Example 2: Set up the Error Detector .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 16
Identify Pattern Generator and Error Detector synchronization problems. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 18
Example 3: Reset the BER and Resyncs to zero .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 19
Reference .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . .. . .. 20
Operating system restore . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 20
User service. .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . . .. . .. 21
Service offerings . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . 21
General care. .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . 21
Preventive maintenance .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 21
Connector replacement . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 23
Fuse replacement . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 23
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual i
Table of Contents
Instrument calibration .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . 23
Repack the instrument for shipment.. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. 23
Specifications . . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . .. . . . 24
Index
ii Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Important safety information
Ground the product. This product is grounded through the grounding conductor of the power cord. To avoid electric
shock, the grounding conductor must be connected to earth ground. Before making connections to the input or output
terminals of the product, make sure that the product is properly grounded.
Do not disable the power cord grounding connection.
Power disconnect. The power cord disconnects the product from the power source. See instructions for the location. Do
not position the equipment so that it is difficult to disconnect the power cord; it must remain accessible to the user at all
times to allow for quick disconnection if needed.
Connect and disconnect properly. Do not connect or disconnect probes or test leads while they are connected
to a voltage source.
Observe all terminal ratings. To avoid fire or shock hazard, observe all ratings and markings on the product. Consult
the product manual for further ratings information before making connections to the product.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual iii
Important safety information
Do not apply a potential to any terminal, including the common terminal, that exceeds the maximum rating of that terminal.
The measuring terminals on this product are not rated for connection to mains or Category II, III, or IV circuits.
Do not operate without covers. Do not operate this product with covers or panels removed, or with the case open.
Hazardous voltage exposure is possible.
Avoid exposed circuitry. Do not touch exposed connections and components when power is present.
Do not operate with suspected failures. If you suspect that there is damage to this product, have it inspected by
qualified service personnel.
Disable the product if it is damaged. Do not use the product if it is damaged or operates incorrectly. If in doubt about safety of
the product, turn it off and disconnect the power cord. Clearly mark the product to prevent its further operation.
Before use, inspect voltage probes, test leads, and accessories for mechanical damage and replace when damaged. Do not
use probes or test leads if they are damaged, if there is exposed metal, or if a wear indicator shows.
Examine the exterior of the product before you use it. Look for cracks or missing pieces.
Use only specified replacement parts.
Use proper fuse. Use only the fuse type and rating specified for this product.
Wear eye protection. Wear eye protection if exposure to high-intensity rays or laser radiation exists.
Do not operate in wet/damp conditions. Be aware that condensation may occur if a unit is moved from a cold to a
warm environment.
Provide proper ventilation. Refer to the installation instructions in the manual for details on installing the product
so it has proper ventilation.
Slots and openings are provided for ventilation and should never be covered or otherwise obstructed. Do not push objects
into any of the openings.
Provide a safe working environment. Always place the product in a location convenient for viewing the display
and indicators.
Avoid improper or prolonged use of keyboards, pointers, and button pads. Improper or prolonged keyboard or pointer use
may result in serious injury.
Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to avoid stress
injuries.
Use care when lifting and carrying the product. This product is provided with handles for lifting and carrying.
iv Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Important safety information
Do not service alone. Do not perform internal service or adjustments of this product unless another person capable of
rendering first aid and resuscitation is present.
Disconnect power. To avoid electric shock, switch off the product power and disconnect the power cord from the mains
power before removing any covers or panels, or opening the case for servicing.
Use care when servicing with power on. Dangerous voltages or currents may exist in this product. Disconnect
power, remove battery (if applicable), and disconnect test leads before removing protective panels, soldering, or replacing
components.
Verify safety after repair. Always recheck ground continuity and mains dielectric strength after performing a repair.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual v
Important safety information
WARNING. Warning statements identify conditions or practices that could result in injury or loss of life.
CAUTION. Caution statements identify conditions or practices that could result in damage to this product or other property.
When this symbol is marked on the product, be sure to consult the manual to find out the nature of the
potential hazards and any actions which have to be taken to avoid them. (This symbol may also be used to
refer the user to ratings in the manual.)
vi Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Compliance information
Compliance information
This section lists the EMC (electromagnetic compliance), safety, and environmental standards with which the instrument
complies.
EMC compliance
EC Declaration of Conformity – EMC
Meets intent of Directive 2004/108/EC for Electromagnetic Compatibility. Compliance was demonstrated to the following
specifications as listed in the Official Journal of the European Communities:
EN 61326-1 2006. EMC requirements for electrical equipment for measurement, control, and laboratory use. 1 2 3
CISPR 11:2003. Radiated and conducted emissions, Group 1, Class A
IEC 61000-4-2:2001. Electrostatic discharge immunity
IEC 61000-4-3:2002. RF electromagnetic field immunity
IEC 61000-4-4:2004. Electrical fast transient / burst immunity
IEC 61000-4-5:2001. Power line surge immunity
IEC 61000-4-6:2003. Conducted RF immunity
IEC 61000-4-11:2004. Voltage dips and interruptions immunity
European contact.
Tektronix UK, Ltd.
Western Peninsula
Western Road
Bracknell, RG12 1RF
United Kingdom
1 This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic interference.
2 Emissions which exceed the levels required by this standard may occur when this equipment is connected to a test object.
3 For compliance with the EMC standards listed here, high quality shielded interface cables should be used.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual vii
Compliance information
Safety compliance
This section lists the safety standards with which the product complies and other safety compliance information.
Canadian certification
CAN/CSA-C22.2 No. 61010-1. Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory
Use – Part 1: General Requirements.
Additional compliances
IEC 61010-1. Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use – Part
1: General Requirements.
Equipment type
Test and measuring equipment.
Safety class
Class 1 – grounded product.
viii Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Compliance information
NOTE. Only mains power supply circuits have an overvoltage category rating. Only measurement circuits have a
measurement category rating. Other circuits within the product do not have either rating.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual ix
Compliance information
Environmental considerations
This section provides information about the environmental impact of the product.
Equipment recycling. Production of this equipment required the extraction and use of natural resources. The equipment
may contain substances that could be harmful to the environment or human health if improperly handled at the product’s
end of life. To avoid release of such substances into the environment and to reduce the use of natural resources, we
encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused
or recycled appropriately.
This symbol indicates that this product complies with the applicable European Union requirements according
to Directives 2002/96/EC and 2006/66/EC on waste electrical and electronic equipment (WEEE) and
batteries. For information about recycling options, check the Support/Service section of the Tektronix Web
site (www.tektronix.com).
Mercury notification. This product uses an LCD backlight lamp that contains mercury. Disposal may be regulated due to
environmental considerations. Please contact your local authorities or, within the United States, refer to the E-cycling Central
Web page (www.eiae.org) for disposal or recycling information.
Perchlorate materials. This product contains one or more type CR lithium batteries. According to the state
of California, CR lithium batteries are classified as perchlorate materials and require special handling. See
www.dtsc.ca.gov/hazardouswaste/perchlorate for additional information.
x Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Preface
Preface
This document provides high-level information on theTektronix BERTScope Bit Error Rate Analyzers. It helps you install
and use the instruments.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual xi
Preface
Documentation
In addition to Quick Start user manual, the following documentation is available on the instrument:
Online help, including remote control commands
Online remote control guide (PDF)
Online help is available for most controls and instrument features. Touch a control on the screen and the select the “Help on
...” listing for help on that control or feature.
Check the Tektronix Web Site for additional product documentation at www.Tektronix.com.
The terms “touch” and “click” are used interchangeably in this document. The instrument has a touchscreen interface to
control the instrument by touching buttons or controls on the screen or by using a mouse.
The terms “view” and “menu” are used interchangeably in this document. A view is defined as the current on-screen menu.
NOTE. A notice statement identifies conditions under which may result in unintended operating modes, incorrect
measurement results, or require resetting the instrument or personal computers operating software interacting with it.
xii Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Product description
Introduction
The Tektronix BERTScope BSA85C, BSA125C, BSA175C, BSA286CL Bit Error Rate Analyzers support serial data interfaces
from 1 Gb Ethernet to future 16x Fibre Channel and 4x 25.78 Gb/s 100 Gb Ethernet. BERTScope Bit Error Rate Analyzers
reduce your time to market by providing the most advanced and comprehensive combination of signal integrity analysis
and test tools available in a single instrument.
The BERTScope analyzer has the comprehensive set of tools you need to perform receiver compliance testing, transmitter
debug, and advanced analysis to 28.6 Gb/s. Featuring easy and flexible stress testing, physical layer analysis such as BER
Contour and Jitter measurements, and a Compliance Contour view for Mask Test, it represents a breakthrough in insight and
saved development time. Compliance Contour is a bridge between BER and mask testing, needed to meet the requirements
of standards such as OIF CEI, 40/100G Ethernet XLAUI/CAUI, and XFP/XFI.
NOTE. Optical transmitter compliance tests such as those required for optical 8x and 16x Fibre Channel, 10 GBASE-SR, LR,
and 40 and 100 GBASE-SR-4, LR-4, SR-10, and ER-4 are best addressed by the Tektronix DSA8300 sampling oscilloscope
with the appropriate reference receiver module.
Use the BERTScope analyzer together with the Tektronix BERTScope Clock Recovery instruments and the Digital
pre-emphasis processors to provide a complete testing solution.
Product description
This document supports the following Tektronix BERTScope Bit Error Rate Analyzers:
BSA85C, Single Channel, BERTScope 8.5 Gb/s Bit Error Rate Analyzer
BSA125C, BERTScope 12.5 Gb/s Bit Error Rate Analyzer
BSA175C, BERTScope 17.5 Gb/s Bit Error Rate Analyzer
BSA286CL, BERTScope 28.6 Gb/s Bit Error Rate Analyzer
The Tektronix BERTScope Bit Error Rate Analyzers provide methods of measuring the signal integrity of serial data systems.
They provide quick, accurate, and thorough bit error ratio detection by bridging eye diagram analysis with BER pattern
generation. These instruments help isolate problematic bit and pattern sequences and analyze seven types of advanced
error analysis with statistical measurement depth.
The instruments have a software-based graphical user interface from a series of View menus. Detailed information on the
operation of the control interface can be accessed at any time through the Help menus available in the separate View menus.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual xiii
Product description
Key specifications
The following key specifications are common to all BSA instruments:
Stressed Eye – SJ, RJ, BUJ, SI:
Option STR
Output Rise Time & Jitter
25 ps, 23 ps typical, rise time (10-90%)
<10 psp-p typical jitter (20-80%)
Output Voltage Range
250 mV to 2 V
Input Sensitivity
100 mVp-p single ended (typical)
50 mVp-p differential (typical)
Options
The following table lists the options available for all BERTScope analyzers:
xiv Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Installation
Installation
Standard accessories
This Quick Start user manual
USB keyboard
USB mouse
Power cord
Short low-loss SMA cables
Optional accessories
Table 1: BERTScope analyzer accessories
Accessory Description
CR125ACBL High performance Delay Matched Cable Set (required for BERTScope analyzer and
Clock Recovery instrument in SSC applications)
100PSRTFILTER 100 ps rise time filter
BSA12500ISI Differential ISI board
PMCABLE1M Precision phase matched cable pair, 1 m
SMAPOWERDIV SMA power dividers
BSARACK BSA-rackmount kits
BSAUSB3 USB3 Instrument Switch with cables and automation software
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 1
Installation
Site considerations
Read this section before installing the instrument. This section describes environmental considerations, operating
requirements, and power considerations.
Place the instrument on a cart or bench. The instrument should rest on its bottom or rear feet. An optional rack mounting kit
is available. Observe the following clearance requirements:
Preventing ESD
CAUTION. A direct electrostatic discharge can damage the instrument input. To learn how to avoid this damage, read
the following information.
Electrostatic discharge (ESD) is a concern when handling any electronic equipment. The instrument is designed with
robust ESD protection; however it is still possible that large discharges of static electricity directly into the signal input
may damage the instrument. To avoid damage to the instrument, use the following techniques to prevent electrostatic
discharge to the instrument.
1. Discharge the static voltage from your body by wearing a grounded antistatic wrist strap while connecting and
disconnecting cables and adapters. The instrument provides a front panel connection for this purpose.
2. A cable that is left unconnected on a bench can develop a large static charge. Discharge the static voltage from all
cables before connecting them to the instrument or device under test by momentarily grounding the center conductor of
the cable, or by connecting a 50 Ω termination to one end, before attaching the cable to the instrument.
2 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Installation
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 3
Installation
4 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Operation
Operation
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 5
Operation
The following figure and table describe the Pattern Generator front panel connectors (outlined in blue).
6 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Operation
The following figure and table describe the Error Detector front panel connectors (outlined in green).
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 7
Operation
8 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Operation
The following figure and table describe the rear panel BNC connectors. Pattern Generator connectors are on a blue
background; Error Detector connectors are on a green background.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 9
Operation
Menu overview
The BERTScope analyzer is controlled by a graphical user interface and on-screen controls. The on-screen controls can be
accessed with the touch screen or with a mouse and keyboard.
The Home view displays when you first turn on the instrument. The Home view introduces the instrument and provides
high-level on-screen information to help you get started using the instrument. It also provides useful links to help you set up
the instrument, such as connecting to the Internet, connecting to a printer, or accessing the Tektronix BERTScope Web site.
The Control console is common to all views. It consists of three major areas to help you control and navigate the different
views:
Title bar. The Title bar contains the name of your instrument and a history of recent views or views within a group.
Touch any of the listed views to quickly return to that view.
Control buttons. Use the buttons on the right side of the display to control the overall instrument operation. The following
table provides a high-level overview of each button.
Touch Run to start the Pattern Generator, Error Detector, or other data analysis
application in the current view. The button lights up while the applications are
running. Touch the button a second time to stop the applications.
10 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Operation
Touch the Help button for easy access to the online help on the current view.
Touch the Shutdown button to quit the BERTScope application or to turn off the
instrument.
Status bar. The Status bar provides information about the current operating status. It is made up of the following
different areas:
Pattern Generator (Gen) and Error Detector (Det). These areas display the data pattern, measured clock frequency,
and synchronization status. The areas will be yellow and display error messages if the system is not in sync.
Measured BER, Error Count, Bit Count. Touch this area to display the measured BER, error count, or bit count. The
small image to the right animates when an analysis is running.
Local/remote control. This area indicates how the instrument is being controlled, locally or by remote control.
NOTE. The Gen or Det areas are shortcuts; touch one of these areas to take you directly to that view.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 11
Operation
12 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Example 1: Configure the Pattern Generator
Applications
The following examples provide simple exercises to help you get familiar with the BERTScope analyzer and to navigate
the instrument views.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 13
Example 1: Configure the Pattern Generator
14 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Example 1: Configure the Pattern Generator
The Pattern Generator is now transmitting PRBS-7 data at 1 Gb/s on the clock and differential Data outputs set to the
industry standard CML levels.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 15
Example 2: Set up the Error Detector
NOTE. Before continuing, make sure that you have the high-quality coaxial cables as describe in Example 1. (See page 13,
Connect the front panel cables.)
16 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Example 2: Set up the Error Detector
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 17
Example 2: Set up the Error Detector
NOTE. In addition to using the View menus to navigate between the Generator and Detector views, you can easily navigate
between the views by touching or clicking the Pattern Generator or Error Detector areas of the Status Bar at the bottom
of the screen.
18 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Example 3: Reset the BER and Resyncs to zero
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 19
Reference
Reference
CAUTION. Using the restore process reformats the hard drive and reinstalls the operating system. All saved data is lost. If
possible, save important files to external media before performing a system restore.
1. Restart the instrument. During the boot-up process you will see the following message at the top of the screen:
Acronis Loader
2. Repeatedly press the F5 key until the Acronis True Image Tool opens. There is a 15-second delay after the message
appears until the instrument proceeds with normal instrument startup. If the instrument does not open the Acronis
application, power off the instrument, then power on the instrument and try again.
3. Touch Restore.
4. In the Confirmation dialog box, touch Yes to restore the instrument operating system, or No to exit the restore process.
The restore process takes approximately 30 minutes; the actual time depends on the instrument configuration.
5. If you have not already done so, go to the Tektronix Web site to download the application software
(www.tektronix.com/software) and follow the instructions to install the software for your instrument.
20 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
User service
User service
This section describes high-level service information and procedures for your instrument.
Service offerings
Tektronix provides service to cover repair under warranty and other services that are designed to meet your specific service
needs.
Whether providing warranty repair service or any of the other services listed below, Tektronix service technicians are well
equipped to service the logic analyzers. Services are provided at Tektronix Service Centers and on-site at your facility,
depending on your location.
General care
Protect the instrument from adverse weather conditions. The instrument is not waterproof. Do not store or leave the
instrument where the display will be exposed to direct sunlight for long periods of time.
CAUTION. To avoid damage to the instrument, do not expose it to sprays, liquids, or solvents.
Preventive maintenance
Preventive maintenance mainly consists of periodic cleaning. Periodic cleaning reduces instrument breakdown and
increases reliability. Clean the instrument as needed, based on the operating environment. Dirty conditions may require
more frequent cleaning than computer room conditions.
CAUTION. Improper cleaning agents or methods can damage the flat panel display.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 21
User service
Do not use abrasive cleaners or commercial glass cleaners to clean the display surface.
Do not spray liquids directly on the display surface.
Do not scrub the display with excessive force.
Avoid getting moisture inside the instrument while cleaning the display; use only enough solution to dampen the wipe.
Clean the flat panel display surface by gently rubbing the display with a cleanroom wipe (such as Wypall Medium Duty
Wipes, #05701, available from Kimberly-Clark Corporation).
If the display is very dirty, moisten the wipe with distilled water or a 75% isopropyl alcohol solution and gently rub the
display surface. Avoid using excess force or you may damage the plastic display surface.
Battery information
The coin cell battery on the instrument computer motherboard is not a user replaceable part. The coin cell battery is not
rechargeable. Under no circumstances attempt to recharge the battery.
22 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
User service
Connector replacement
The Pattern Generator CLOCK OUTPUT and CLOCK INPUT connectors and the Error Detector DATA OUTPUT and DATA
INPUT connectors use 3.5 mm to PAC Planar Crown® adapters. These facilitate user replacement of the adapter, should it
become damaged. Replacement adapters can be ordered from Tektronix.
Fuse replacement
The instrument is protected by a fuse placed in series with the power line input. The fuse is conservatively rated and should
never open through the life of the instrument. A blown fuse would generally indicate a problem with the instrument which
requires factory service. It is recommended that you arrange to have the instrument serviced if you experience a blown fuse.
Instrument calibration
The instrument uses digital calibration of the output buffers. To maintain the accuracy of the output amplitude and offset,
annual calibration is recommended. Contact Tektronix to schedule instrument calibration.
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 23
Specifications
Specifications
Table 11: PC-related specifications
Characteristic Description
Display TFT Touch screen, 640 x 480 VGA
Touch sensor Analog resistive
Processor Pentium® P4; 1.5 GHz or greater
Hard disk drive 160 GB or greater
DRAM 2 GB
Operating system Microsoft Windows 7 Professional
Remote control IEEE-488 (GPIB) or TCP/IP
Network connection 100 base T Ethernet LAN
Supported interfaces USB 2.0 (6 total, 2 front, 4 rear)
VGA external display
24 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual
Index
Index
A environmental L
About tab, 12 considerations, 2 Log tab, 12
accessories specifications, 24 low-frequency sine jitter in
optional, 1 error blank input Pattern Generator, 9
standard, 1 Error Detector, 7 low-frequency sine jitter out
application software, 20 Error Detector Pattern Generator, 9
clock input, 7
data input, 7
B detector start input, 9 M
battery information, 22 error blank input, 7 maintenance
error output, 7 cleaning, 21, 22
front panel connectors, 7 preventive, 21
C marker input, 7 manual
calibration, 23 set up, 16 conventions, xii
cleaning synchronization problems, 18 marker input
exterior, 22 trigger output, 7 Error Detector, 7
flat panel display, 21 error output
clearance requirements, 2 Error Detector, 7
clock input ESD, 2 O
Error Detector, 7 external clock input on-screen controls, 10
clock output Pattern Generator, 6 online help, xii
Pattern Generator, 6 operating requirements, 2
compliance operating system restore, 20
optical transmitter, xiii F optional accessories, 1
connector replacement, 23 features and benefits, xi options, xiv
connectors flat panel display
Error Detector, 7 cleaning, 21
front panel, 5, 6, 7 front panel P
Pattern Generator, 6 connectors, 5, 6, 7 packaging, 23
rear panel, 8, 9 front panel connectors page select
control buttons, 10 Error Detector, 7 Pattern Generator, 9
Control console, 10 Pattern Generator, 6 Pattern Generator
conventions, xii fuse clock output, 6
replacement, 23 data output, 6
specifications, 2 external clock input, 6
D front panel connectors, 6
data input high-frequency jitter input, 6, 9
Error Detector, 7 H low-frequency sine jitter in, 9
data output high-frequency jitter input low-frequency sine jitter out, 9
Pattern Generator, 6 Pattern Generator, 6, 9 page select, 9
detector start input Home view, 3, 10 pattern start input, 9
Error Detector, 9 reference in, 9
documentation, xii reference out, 9
K set up, 13
key features, xi sine interference out, 9
E key specifications, xiv subrate clock, 6
electrostatic discharge, 2 subrate clock output, 6
synchronization problems, 18
trigger output, 6
Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual 25
Index
26 Tektronix BERTScope Bit Error Rate Analyzers Quick Start User Manual