Sheet 1 of 1
Customer : Pertamina - Lampung Project : Replacement FCV-104 Valve Tag # : FCV-104
Control Valve Specification PO # : Proj Num : Page # : 1
Prepared By : Quote # : Q. ID : steven_SGYJ7494PNXT_59 P&ID :
Rev/By : 0.0 / steven Alternate : Line :
Application : Liquid LPG Date / Ver : 02-Jul-2020 / 12.7300
1 Pipe Size, Up/Down 4.000 / 4.000 51 Act. Type/Matl VL Cylinder / Aluminum
Process Data For Control Valve Selection
2 Pipe Sch, Up/Down 40 / 40 52 Act. Size/Instr. Sup. 50 / Air
3 Allow Noise/Add Attn/Type 90 / 0 / 53 Stroke/Spring 2.00 / Standard
4 Process Fluid Liquid LPG 54 Fail/Air-To Open / Close
Actuator
5 Design Press./Temp. 0.00 / 18.00 kg/cm² (g) / -10.00 / 60.00 °C 55 Vol Tank/Orient/Mtg / /
6 Driving Cond. Minimum Normal Maximum Cond4 56 Tubing Size/Mtl 1/4" / 304 SS
7 Temperature (°C) 20.000 35.000 40.000 57 Fitting Mfg/Mtl Bi-Lok / 316 SS
8 Inlet Press (kg/cm² (g)) 6.500 9.100 10.100 58 Pos. Ornt./HW HVR / Side Mnt/Cont Connect
9 Outlet Press (kg/cm² (g)) 6.000 8.600 9.600 59 Actuator O-Rings Buna-N
10 Liq Flow Rate (m³/h) 0 65.000 71.500 60 Spud 2.62 / 1.00 - 12 UNF
11 Gas Flow Rate (1000 SCFH) 0 0 0 61
12 Viscosity (cP) 0.133 0.116 0.111 62 Model Logix 3000 Series / MD
13 Vapor Press (kg/cm² (a)) 5.610 8.230 9.270 63 Model # 3200MD-10-D6-E-04-40-0G-00
14 SG-MW 0.539 0.519 0.512 64 Diagnostic Standard
15 Max Shutoff / Shutoff Class 18.000 kg/cm² / Class IV 65 Comm/Signal HART / 4 - 20 mA
16 Min Supply Pressure 4.000 kg/cm² (g) 66 Housing/Conn Aluminum, White / 1/2" NPT
Positioner
17 Valve Function Throttling 67 Piezo Temp/ITK Opt / None
18 Driving Cond. Minimum Normal Maximum Cond4 68 Shaft Linear-D Shaft
19 Flow Coeff. 0 77.322 84.477 69 Action 4-Way
Calculated Data
(Cv)
20 Est Stroke (% Lift) 0.000 63.000 65.000 70 Feedback None
21 Pressure Drop (kg/cm²) 0.000 0.500 0.500 71 Gauges 2 SS-Brass PSI/BAR/KPA
22 Choke Drop (kg/cm²) 0.000 2.728 2.882 72 Pos Tag/Mounting /
23 Noise [IEC] (dBA) --- <70 <70 73 Model
24 Valve Vel (ft/s) 0 7.311 8.042 74
25 Pipe Vel (ft/s) 0 7.217 7.939 75
Pos Ind Sw
26 Model / Body Type / Trim Type Mark One / Globe / Standard 76
27 Size/Pressure Class/Body Form 4.00 / CL 300 / Cast 77
28 Trim # - Cv / Characteristic 2.62 Cv:133 / Equal Percent 78
29 Stages / Design / / / 79
30 Flow Direction Flow Under 80
31 Body Matl / Bonnet Matl Carbon Steel (WCC) / Carbon Steel 81
32 End Conn/Sch/Face to Face Integral Flange / / ISA S75.08.01 82 Model/Qty /
33 Flange Finish 125 - 250 Ra 83 Cv-Kv/De-en /
34 Bonnet / Drip Plate / Cryo Type Standard / / 84 Volt/Watt /
Solenoid
35 Balance Type / P/B Seal Matl. Unbalanced / 85 Body/Housing Mtl /
36 Plug Mtl/ Facing|Treatment /Stem Cvr316 SS / Full Cont. Alloy 6 / 86 Body/Elect Conn /
37 Stem Mtl/ Facing|Treatment /Pilot Spr316 SS / / 87 Port Size/Mtg /
Valve Body Assembly
38 Seat Ring Mtl/ Facing|Treatment 316 SS / Full Bore Alloy 6 88 Tag/Reset-Override / / /
39 Seat Style / Soft Material / / 89 Air Filter/Mnting /
40 Seat Retainer Mtl/ Facing|Treatment 316 SS / 90 Filter-Reg/Mnting Valtek / Nipple Mtd
41 Sleeve Mtl/ Facing|Treatment / 91 Flow Booster / Mtg. /
42 Guides Upper/Lower 316 SS & GL PTFE / 316 SS & GL PTFE 92 Booster Config
43 Packing Matl / Style / Vac / Fire / Cert PTFE V-Ring / Single / / / 93 Quick Exhaust /
44 Packing - Live-Loaded 94 SupTube/Jctn Box /
Others
45 Bonnet Port / Body Drain / 95 Lockup/Mnting /
46 Bellows Type / Material / 96 Plate ID
47 Body Bolting/Bonnet Flange Matl B7-2H Zinc Plated / Carbon Steel 97 Plate Type
48 Gaskets Spiral Graphite 98 Packaging Standard
49 Gland Flange Material Stainless Steel 99 Pwr. Sup.
50 Gland Flange Bolting Carbon Steel, Zinc Plated 00 Wiring Conn. Type
T1 01 Rad. Exm/Mat Regu /
T2 02 Drawings Type I - CAD w/ Schematics
T3 03 Assem Hydro ISA-S75.19
T4 04 Seat leak/Final test cert. ANSI/FCI 70-2 (SPP-433) /
01 Certification/Approval Type / / 05 PMI/Weld Req / ASME BPVC Section IX
Customer Spec
02 Class or Gas Group No Cert Req 06 Cert of Conf. PO or Spec.
03 Division or Zone No Cert Req 07 Cln/Bld/Doc/Act Cln / Final Insp /
Special Req
04 Group No Cert Req 08 CMTR/Mat Cert. Body & Bonnet / EN 10204 3.1
05 Ingress / Temperature NEMA 4,4X / 09 Special Paint/Test Epoxy /
06 NACE / Nuclear NA / NA 10 Diag Test/FM /
07 SIL Vlv-Act / Pos NA / NA 11 Cust. Insp/Witn. No / No
08 Oxygen Service/Assy. Lubricant NA / 12 Material Req/ND /
13 Cust Furnish None
14 Flow Testing
S1
S2
Line # : Remarks :
DB Rev - 606 : 31-Aug-2020 : ID = steven_SGYJ7494PNXT_59 Quantity: 1
E* N L
OPEN NEUTRAL CLOSE
OPEN
K A
* - DISASSEMBLY / MAINTENANCE CLEARANCE
A E F J K L M N P WT
INCH 14.50 7.5 34.4 9.1 9.0 7.3 12.0 12.8 18.7 268 LBS
MM 368.3 190 874 232 229 185 305 324 475 122 KG
Note: Dimensions are correct per associated specification sheet. End connections
and scaling may not actual. For accessory information, see associated specification sheet.
MODEL ACTUATOR
Mark One 50 SQ IN DIMENSIONAL DRAWING
SIZE AIR TO BY CUSTOMER ITEM
4 INCH CLOSE steven Pertamina - Lampung 1
RATING / F/F STD FAIL DATE VALVE TAG SHEET
CL 300 / S75.08.01 Open 02-Jul-2020 FCV-104 1
END CONNECTION SPRING THIRD ANGLE PROJECTION P.O. NUMBER REVISION
INT FLG STANDARD 0.0
TRIM TYPE TRIM / CV PROJECT SERIAL NUMBER
STD 2.62 /Cv:133 Replacement FCV-104 .001
DB Rev - 606 : 31-Aug-2020
Customer : Pertamina - Lampung Project : Replacement FCV-104 Valve Tag # : FCV-104
Detail Information PO # : Proj Num : Page # : 1
Prepared By : Quote # : Q. ID : steven_SGYJ7494PNXT_59 P&ID :
Rev/By : 0.0 / steven Alternate : Line :
Application : Liquid LPG Date / Ver : 02-Jul-2020 / 12.7300
4.00 in (Trim: 2.62 Cv:133) CL 300 Mark One Standard Globe
Minimum Normal Maximum
Process Data
Temp (°C) 20.000 35.000 40.000 --- --- --- --- --- --- ---
P1 (kg/cm² (g)) 6.500 9.100 10.100 --- --- --- --- --- --- ---
P2 (kg/cm² (g)) 6.000 8.600 9.600 --- --- --- --- --- --- ---
Liq Flow (m³/h) 0.000 65.000 71.500 --- --- --- --- --- --- ---
Gas Flow (1000 SCFH) --- --- --- --- --- --- --- --- --- ---
Visc (cP) 0.133 0.116 0.111 --- --- --- --- --- --- ---
VP (kg/cm² (a)) 5.610 8.230 9.270 --- --- --- --- --- --- ---
DP (kg/cm²) 0.000 0.500 0.500 --- --- --- --- --- --- ---
DpC (kg/cm²) 0.000 2.728 2.882 --- --- --- --- --- --- ---
Vel (ft/s) 0.000 7.311 8.042 --- --- --- --- --- --- ---
Pipe Vel (ft/s) 0.000 7.217 7.939 --- --- --- --- --- --- ---
Noise (dBA) ---- < 70.0 < 70.0 --- --- --- --- --- --- ---
Flow Cap (Cv) 0 77.322 84.477 --- --- --- --- --- --- ---
Stroke (% Lift) 0 63 65 --- --- --- --- --- --- ---
Info () --- --- --- --- --- --- --- --- --- ---
Detailed Miscellaneous Information
FP --- 1.000 1.000 --- --- --- --- --- --- ---
FL 0.000 0.916 0.913 --- --- --- --- --- --- ---
FR 0.000 1.000 1.000 --- --- --- --- --- --- ---
Sg 0.539 0.519 0.512 --- --- --- --- --- --- ---
K --- --- --- --- --- --- --- --- --- ---
Xt --- --- --- --- --- --- --- --- --- ---
Z --- --- --- --- --- --- --- --- --- ---
FD --- --- --- --- --- --- --- --- --- ---
MWT --- --- --- --- --- --- --- --- --- ---
Detailed Cavitation (Sigma) Information
Sigma 3.847 3.807 3.727 --- --- --- --- --- --- ---
Sigma MR 1.456 1.574 1.611 --- --- --- --- --- --- ---
PSE 0.867 0.866 0.864 --- --- --- --- --- --- ---
SSE --- 1.029 1.030 --- --- --- --- --- --- ---
Sigma V --- 1.537 1.570 --- --- --- --- --- --- ---
Sigma P --- 1.537 1.570 --- --- --- --- --- --- ---
135.71 Fluid: Liquid LPG
Type: Full
122.14 Owner: EVERYONE Fluid List: RECORD
Vp Equation: Antoine
108.57
Critical Pressure (psi (a)/bar (a)) : 597.810 / 41.228
Critical Temperature (°F/°C) : -116.950 / -82.750
95.00
Reference Specific Gravity: override exists - see above conditions summary
3 Molecular Weight: 50.150
81.43 2 Specific Heat Ratio: 1.070
Reference Temperature (°F/°C) : -258.570 / -161.428
67.86 Vp-A: 13.400 Vp-B: 2880.500
Vp-C: 69.800
Cv
54.29
Minimum Temperature (°F/°C) : -295.870 / -182.150
40.71 Maximum Temperature (°F/°C) : -117.670 / -83.150
Bulk Modulas ((lbf/in²)/(kg/cm²)) : 340000.000 / 4835820.000
27.14
13.57
0.00
0 10 20 30 40 50 60 70 80 90 100
Percent Open
Flow Direction : Flow Under
Trim Characteristic : Equal Percent
Balance Type: Unbalanced
Trim Type : Standard
DB Rev - 606 : 31-Aug-2020