Data sheet 6AG1214-1BE30-2XB0
***Spare part*** SIPLUS S7-1200 CPU 1214C AC/DC/relay -25...+70
°C with conformal coating based on 6ES7214-1BE30-0XB0 .
compact CPU, AC/DC/relay, onboard I/O: """14 DI 24 V DC; 10 DO
relay 0" 5 A 2 AI 0-10 V DC, Power supply: AC 85-264 V AC @ 47-
63 Hz, Program/data memory 50 KB
General information
Product type designation CPU 1214C AC/DC/relay
Engineering with
● Programming package STEP 7 Basic V10.5
Supply voltage
Rated value (AC)
● 120 V AC Yes
● 230 V AC Yes
permissible range, lower limit (AC) 85 V
permissible range, upper limit (AC) 264 V
Line frequency
● permissible range, lower limit 47 Hz
● permissible range, upper limit 63 Hz
Load voltage L+
● Rated value (DC) 24 V
● permissible range, lower limit (DC) 5 V
● permissible range, upper limit (DC) 250 V
Input current
6AG1214-1BE30-2XB0 Subject to change without notice
Page 1/8 03/07/2019 © Copyright Siemens
Current consumption (rated value) 100 mA at 120 V AC; 50 mA at 240 V AC
Current consumption, max. 300 mA at 120 V AC; 150 mA at 240 V AC
Inrush current, max. 20 A; at 264 V
Output current
for backplane bus (5 V DC), max. 1 600 mA; Max. 5 V DC for SM and CM
Encoder supply
24 V encoder supply
● 24 V Permissible range: 20.4V to 28.8V
Power loss
Power loss, typ. 14 W
Memory
Work memory
● integrated 50 kbyte
● expandable No
Load memory
● integrated 2 Mbyte
● Plug-in (SIMATIC Memory Card), max. 24 Mbyte; with SIEMENS Memory Card
Backup
● present Yes; Entire project maintenance-free in the integral EEPROM
● without battery Yes
CPU processing times
for bit operations, typ. 0.1 µs; / Operation
for word operations, typ. 12 µs; / Operation
for floating point arithmetic, typ. 18 µs; / Operation
CPU-blocks
Number of blocks (total) DBs, FCs, FBs, counters and timers. The maximum number of
addressable blocks ranges from 1 to 65535. There is no
restriction, the entire working memory can be used
OB
● Number, max. Limited only by RAM for code
Data areas and their retentivity
Retentive data area (incl. timers, counters, flags), 2 048 byte
max.
Flag
● Number, max. 8 kbyte; Size of bit memory address area
Address area
I/O address area
● Inputs 1 024 byte
● Outputs 1 024 byte
Process image
6AG1214-1BE30-2XB0 Subject to change without notice
Page 2/8 03/07/2019 © Copyright Siemens
● Inputs, adjustable 1 kbyte
● Outputs, adjustable 1 kbyte
Hardware configuration
Number of modules per system, max. 3 communication modules, no signal board can be used, 8 signal
modules
Time of day
Clock
● Hardware clock (real-time) Yes
● Backup time 240 h; Typical
● Deviation per day, max. ±60 s/month at 25 °C
Digital inputs
Number of digital inputs 14; Integrated; > +60 °C Number of simultaneously controllable
inputs and outputs max. 50 %
● of which inputs usable for technological 6; HSC (High Speed Counting)
functions
Source/sink input Yes
Input voltage
● Rated value (DC) 24 V
● for signal "0" 5 V DC at 1 mA
● for signal "1" 15 V DC at 2.5 mA
Input current
● for signal "1", typ. 1 mA
Input delay (for rated value of input voltage)
for standard inputs
— parameterizable 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms,
selectable in groups of four
— at "0" to "1", min. 0.2 ms
— at "0" to "1", max. 12.8 ms
for interrupt inputs
— parameterizable Yes
for technological functions
— parameterizable Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80
kHz & 3 @ 30 kHz
Cable length
● shielded, max. 500 m; 50 m for technological functions
● unshielded, max. 300 m; For technological functions: No
Digital outputs
Number of digital outputs 10; Relay; > +60 °C Number of simultaneously controllable inputs
and outputs max. 50%
Short-circuit protection No; to be provided externally
Switching capacity of the outputs
6AG1214-1BE30-2XB0 Subject to change without notice
Page 3/8 03/07/2019 © Copyright Siemens
● with resistive load, max. 2 A
● on lamp load, max. 30 W with DC, 200 W with AC
Output delay with resistive load
● "0" to "1", max. 10 ms; max.
● "1" to "0", max. 10 ms; max.
Switching frequency
● of the pulse outputs, with resistive load, max. 1 Hz
Relay outputs
● Number of relay outputs 10
● Number of operating cycles, max. mechanically 10 million, at rated load voltage 100 000
Cable length
● shielded, max. 500 m
● unshielded, max. 150 m
Analog inputs
Number of analog inputs 2; > +60 °C Number of simultaneously controllable inputs and
outputs max. 50%
Input ranges
● Voltage Yes
Input ranges (rated values), voltages
● 0 to +10 V Yes
● Input resistance (0 to 10 V) ≥100k ohms
Cable length
● shielded, max. 100 m; twisted and shielded
Analog outputs
Number of analog outputs 0
Cable length
● shielded, max. 100 m; shielded, twisted pair
Analog value generation for the inputs
Integration and conversion time/resolution per channel
● Resolution with overrange (bit including sign), 10 bit
max.
● Integration time, parameterizable Yes
● Conversion time (per channel) 625 µs
Encoder
Connectable encoders
● 2-wire sensor Yes
1. Interface
Interface type PROFINET
Physics Ethernet
Isolated Yes
6AG1214-1BE30-2XB0 Subject to change without notice
Page 4/8 03/07/2019 © Copyright Siemens
automatic detection of transmission rate Yes
Autonegotiation Yes
Autocrossing Yes
Protocols
● PROFINET IO Controller Yes
Protocols
Supports protocol for PROFINET IO No
PROFIBUS No
AS-Interface No
Protocols (Ethernet)
● TCP/IP Yes
Open IE communication
● TCP/IP Yes
● ISO-on-TCP (RFC1006) Yes
Web server
● supported Yes
● User-defined websites Yes
Further protocols
● MODBUS No
Communication functions
S7 communication
● supported Yes
● as server Yes
Number of connections
● overall 15; dynamically
Test commissioning functions
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers,
counters
Forcing
● Forcing Yes
Integrated Functions
Number of counters 6
Counting frequency (counter) max. 100 kHz
Frequency measurement Yes
controlled positioning Yes
PID controller Yes
Number of alarm inputs 4
Potential separation
Potential separation digital inputs
6AG1214-1BE30-2XB0 Subject to change without notice
Page 5/8 03/07/2019 © Copyright Siemens
● Potential separation digital inputs No
● between the channels, in groups of 1
Potential separation digital outputs
● Potential separation digital outputs Relays
● between the channels No
● between the channels, in groups of 2
Permissible potential difference
between different circuits 500 V DC between 24 V DC and 5 V DC
EMC
Interference immunity against discharge of static electricity
● Interference immunity against discharge of Yes
static electricity acc. to IEC 61000-4-2
— Test voltage at air discharge 8 kV
— Test voltage at contact discharge 6 kV
Interference immunity to cable-borne interference
● Interference immunity on supply lines acc. to Yes
IEC 61000-4-4
● Interference immunity on signal cables acc. to Yes
IEC 61000-4-4
Interference immunity against voltage surge
● on the supply lines acc. to IEC 61000-4-5 Yes
Interference immunity against conducted variable disturbance induced by high-frequency fields
● Interference immunity against high-frequency Yes
radiation acc. to IEC 61000-4-6
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes; Group 1
● Limit class B, for use in residential areas Yes; When appropriate measures are used to ensure compliance
with the limits for Class B according to EN 55011
Degree and class of protection
Degree of protection acc. to EN 60529
● IP20 Yes
Standards, approvals, certificates
CE mark Yes
UL approval Yes
cULus Yes
Ambient conditions
Free fall
● Fall height, max. 0.3 m; five times, in product package
Ambient temperature during operation
● horizontal installation, min. -25 °C; = Tmin
6AG1214-1BE30-2XB0 Subject to change without notice
Page 6/8 03/07/2019 © Copyright Siemens
● horizontal installation, max. 70 °C; = Tmax; > +60 °C Number of simultaneously controllable
inputs and outputs max. 50%; no signal board can be used
● vertical installation, min. -25 °C; = Tmin
● vertical installation, max. 45 °C; = Tmax
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Ambient air temperature-barometric pressure- Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) //
altitude Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500
m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ...
+5 000 m)
Relative humidity
● With condensation, tested in accordance with 100 %; RH incl. condensation/frost permitted (no commissioning
IEC 60068-2-38, max. in bedewed state)
Vibrations
● Vibration resistance during operation acc. to 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail
IEC 60068-2-6
● Operation, tested according to IEC 60068-2-6 Yes
Shock testing
● tested according to IEC 60068-2-27 Yes; 15 g (m/s²), 11 ms pulse, 6 shocks in each of 3 axes
Resistance
Use in stationary industrial systems
— to biologically active substances according Yes; Class 3B2 mold, fungus and dry rot spores (with the
to EN 60721-3-3 exception of fauna); Class 3B3 on request
— to chemically active substances according Yes; Class 3C4 incl. salt spray according to EN 60068-2-52
to EN 60721-3-3 (degree of severity 3). The supplied connector covers must
remain on the unused interfaces during operation!
— to mechanically active substances Yes; Class 3S4 incl. sand, dust. The supplied connector covers
according to EN 60721-3-3 must remain on the unused interfaces during operation!
Configuration
Programming
Programming language
— LAD Yes
— FBD Yes
— SCL Yes
Cycle time monitoring
● adjustable Yes
Dimensions
Width 110 mm
Height 100 mm
Depth 75 mm
Weights
6AG1214-1BE30-2XB0 Subject to change without notice
Page 7/8 03/07/2019 © Copyright Siemens
Weight, approx. 455 g
last modified: 03/05/2019
6AG1214-1BE30-2XB0 Subject to change without notice