0% found this document useful (0 votes)
35 views

Features: Econoline

The document describes the REC8-xxxxSRW/DRW series of regulated DC/DC converters. Key features include: - Single and dual output versions available in a DIP24 or SMD package with 2kV or 3kV isolation. - Remote on/off control and synchronous rectification on some outputs. - Full protection against overloads and short circuits. - High efficiency up to 87%, with options for input voltages between 4.5-75V and output voltages of 3.3V, 5V, 12V, and 15V.

Uploaded by

MedoBoudy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
35 views

Features: Econoline

The document describes the REC8-xxxxSRW/DRW series of regulated DC/DC converters. Key features include: - Single and dual output versions available in a DIP24 or SMD package with 2kV or 3kV isolation. - Remote on/off control and synchronous rectification on some outputs. - Full protection against overloads and short circuits. - High efficiency up to 87%, with options for input voltages between 4.5-75V and output voltages of 3.3V, 5V, 12V, and 15V.

Uploaded by

MedoBoudy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Features ●


8W DIP24 Package
2KVDC and 3kVDC Isolation Options
ECONOLINE
● 2:1 and 4:1 Versions
DC/DC-Converter
Regulated ● Continuous Short Circuit Protection with 3 year Warranty
Converters (power limiting)
● Synchronous Rectification on 3.3, 5V outputs
● Full SMD internal design
● Through Hole or SMD Pinning Options
● Remote Control Pin
● Efficiency to 87% 8 Watt
Description The REC8-xxxxSRW/DRW-series offer single and dual regulated outputs in a DIP24 package with
2kV or 3kV isolation options and are suitable for higher power industrial or medical applications.
DIP24 & SMD
Remote on/off control is standard and SMD pinning is offered with the /SMD option.
The converters can deliver 150% rated power for short periods of time to cope with applications Single & Dual
with large capacitive loads or high start up currents.
Output
Selection Guide
Part Input Output Output Efficiency Max. Cap.
Number Voltage Voltage Current Load
(VDC) (VDC) (mA) (%)
REC8-xx3.3SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 3.3 1600 83-85 2200µF
REC8-xx05SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 5 1600 85-87 2200µF
REC8-xx12SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 12 666 84-86 470µF
REC8-xx15SRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 15 533 84-86 220µF
REC8-xx05DRW/H*/A/M 9-18, 18-36, 36-75 ±5 ±800 84 ±1000µF
REC8-xx12DRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 ±12 ±333 84-86 ±220µF RoHS
2002/95/EC
6/6
REC8-xx15DRW/H*/A/M 4.5-9, 9-18, 18-36, 36-75 ±15 ±267 84-86 ±100µF E-224736
REC8-xx3.3SRWZ/H*/A/M 9-36, 18-75 3.3 1600 84 2200µF EN-60950-1 Certified
REC8-xx05SRWZ/H*/A/M 9-36, 18-75 5 1600 86 2200µF UL-60950-1 Certified
REC8-xx12SRWZ/H*/A/M 9-36, 18-75 12 666 85 470µF
REC8

REC8-xx15SRWZ/H*/A/M
REC8-xx05DRWZ/H*/A/M
9-36, 18-75
9-36, 18-75
15
±5
533
±800
85
83
220µF
±1000µF
REC8
REC8-xx12DRWZ/H*/A/M 9-36, 18-75 ±12 ±333 85 ±220µF
REC8-xx15DRWZ/H*/A/M 9-36, 18-75 ±15 ±267 85 ±100µF
* Standard is /H2 for 2kVDC isolation, 2:1 4:1
use /H3 for 3kVDC Isolation (not SMD) xx = 4.5-9Vin = 05, xx = 9-36Vin = 24,
* add suffix “/SMD” for SMD package, e.g. xx = 9-18Vin = 12, xx = 18-75Vin = 48
REC8-2405SRW/H2/A/M/SMD xx = 18-36Vin = 24,
xx = 36-75Vin = 48

Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range 2:1 & 4:1
Input Filter PI Network
Output Voltage Accuracy ±1.5% max.
Line Voltage Regulation (VL to VH at full load) ±0.5% max.
Load Voltage Regulation Single ±0.5% max.
(25% to 100% full load ) Dual ±1.2% max.
Cross Regulation (100%: 25% to 100% full load ) ±5% max.
Output Ripple and Noise (with 100n output capacitor and 20MHz BW) 50mVp-p max.
Start-up time 300ms typ.
Operating Frequency (Full Load) 330kHz typ.
Efficiency at Full Load see Selection Guide
Minimum Load 0%
cont. Refer to Application Notes

E-114 REV: 0/2011 www.recom-electronic.com


ECONOLINE REC8-S_DRW(Z)/H*/A/M
DC/DC-Converter Series
Specifications cont. (measured at TA = 25°C, nominal input voltage, full load and after warm-up)

Input Surge Voltage (100ms max.) 5V Input


12V Input
15VDC
36VDC
Derating-Graph
24V Input 50VDC (Ambient Temperature)
48V Input 100VDC
Isolation Voltage /H2 and SMD (tested for 1 second) 2000VDC 2:1 Converters
(rated for 1 minute) 1000VAC / 60Hz
Safe Operating Area
/H3 Version (tested for 1 second) 3000VDC 100
(rated for 1 minute) 1500VAC / 60Hz 2:1 - All Others
80
Isolation Capacitance 1200pF typ.
2:1 Vin =5V
Isolation Resistance 1 GΩ min. 60

Output Power (%)


Overload Protection 150% typ. 40
Short Circuit Protection Continuous, Auto Restart 20
Operating Temperature Range 4:1 -40°C to +71°C (see Graph)
2:1- Vin=5V -40°C to +71°C (see Graph) 0
-40 0 50 85 100 150
(free air convection) 2:1 - All Others -40°C to +85°C (see Graph)
71
Remote On/Off DC/DC ON Open or 3.5V<Vr<12V
Operating Temperature °C
DC/DC OFF Short or 0V<Vr<1.2V
Storage Temperature Range -55°C to +105°C 4:1 Converters
Temperature Coefficient ±0.05% max.
Safe Operating Area
Relative Humidity 95% RH max. 100
4:1
Case Material Nickel Plated Metal with Non-Conductive Base 80
Thermal Impedance Natural convection 12°C/W
60
Output Power (%)
Maximum Case Temperature 100°C
Vibration 10-55Hz, 2G, 30mins along X,Y & Z 40
Package Weight 18g 20
Packing Quantity 15 pcs per Tube
0
50 75 100
MTBF (+25°C)
} Detailed Information see
using MIL-HDBK 217F 1200 x 103hours -40 0 150

REC8
(+71°C) Application Notes chapter "MTBF" using MIL-HDBK 217F >300 x 103hours
Operating Temperature °C

Typical Characteristics
REC8-1205SRW/H2/A/M (/SMD)
REC8-1212SRW/H2/A/M (/SMD)

Efficiency / Load (Nominal Vin) Efficiency VS Input Voltage


100
1205S
90 1205
80 88
1212S 86
Efficiency %

60 84
1212
82
40 80
78
Efficiency (%)

20 76
74
72
0
70
0% 20% 40% 60% 80% 100% 9 10 12 16 18
14
Total Output current (%)
Input Voltage (V)

Note: Refer to Application Notes for EMC Class B Filter suggestion

www.recom-international.com REV:0/2011 E-115


ECONOLINE REC8-S_DRW(Z)/H*/A/M
DC/DC-Converter Series
Specifications (cont.)

Certifications
EN General Safety Report: PS090302950C2 EN60950-1:2006
UL General Safety Report: E248550 UL 60950-1 1st Ed.
C22.2 No. 60950-1-03

Package Style and Pinning (mm)


24 PIN DIP Package - Available with /H2 and /H3 Options 3rd angle
projection

32.00 20.30
Pin Connections DIP24

10.20 Pin # Single Dual


1 CTRL CTRL
4.10 2 –Vin –Vin
2.03 0.50 15.24 3 –Vin –Vin
9 NC Com
Recommended Footprint Details 11 NC –Vout
14 +Vout +Vout
1.00 ø+0.15/–0
16 – Vout Com
22 +Vin +Vin
1 2 3 9 11
23 +Vin +Vin
Bottom View NC = No Connection

23 22 16 14 2.54
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Top View
2.54
REC8

24 PIN SMD Package - available with /H2 option only.

32.00 19.90
31.40

Pin Connections DIP24 SMD


11.20 10.90
Pin # Single Dual
1 CTRL CTRL
2.54 3.81 6.35 20.30
2 –Vin –Vin
25.40
3 –Vin –Vin
Recommended Footprint Details 9 NC Com
11 NC –Vout
Pin area 2.54 1.54 14 +Vout +Vout
0.1 x 0.50 0.50
16 – Vout Com
2.03
1 2 3 4 5 9 10 11 12 22 +Vin +Vin
23 +Vin +Vin
4,5,10,12 NC
23.40 Bottom View 26.67 Top View
13,15,20,21,24 NC
24.64
1 NC = No Connection
24 23 22 21 20 16 15 14 13
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
11 x 2.54 27.94

E-116 REV: 0/2011 www.recom-electronic.com