0% found this document useful (0 votes)
69 views

Data Sheet 6ES7517-3HP00-0AB0: General Information

Uploaded by

anas raddawi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views

Data Sheet 6ES7517-3HP00-0AB0: General Information

Uploaded by

anas raddawi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Data sheet 6ES7517-3HP00-0AB0

SIMATIC S7-1500H, CPU 1517H-3 PN, central processing unit with


work memory 2 MB for program and 8 MB for data, 1st interface:
PROFINET RT With 2-port switch, 2nd interface: PROFINET, 3rd/4th
interface: H-SYNC, SIMATIC memory card required
******************************* Special release required. Please contact
your Siemens representative

General information
Product type designation CPU 1517H-3 PN
HW functional status FS02
Firmware version V2.8
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No

Display
Screen diagonal [cm] 6.1 cm

Control elements
Number of keys 6
Mode selector switch 1

Supply voltage
Type of supply voltage 24 V DC
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering

6ES7517-3HP00-0AB0 Subject to change without notice


Page 1/8 04/28/2020 © Copyright Siemens
● Mains/voltage failure stored energy time 5 ms

Input current
Current consumption (rated value) 1.5 A
Inrush current, max. 2.4 A; Rated value
I²t 0.02 A²·s

Power loss
Power loss, typ. 24 W

Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 2 Mbyte
● integrated (for data) 8 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes

CPU processing times


for bit operations, typ. 4 ns
for word operations, typ. 6 ns
for fixed point arithmetic, typ. 6 ns
for floating point arithmetic, typ. 24 ns

CPU-blocks
Number of elements (total) 12 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range Number range: 1 to 59 999
● Size, max. 8 Mbyte; For non-optimized block accesses, the max. size of the
DB is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
FC
● Number range 0 ... 65 535
● Size, max. 1 Mbyte
OB
● Size, max. 1 Mbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20

6ES7517-3HP00-0AB0 Subject to change without notice


Page 2/8 04/28/2020 © Copyright Siemens
● Number of process alarm OBs 50
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
● Number of diagnostic alarm OBs 1
Nesting depth
● per priority class 24

Counters, timers and their retentivity


S7 counter
● Number 2 048
Retentivity
— adjustable Yes
IEC counter
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes
S7 times
● Number 2 048
Retentivity
— adjustable Yes
IEC timer
● Number Any (only limited by the main memory)
Retentivity
— adjustable Yes

Data areas and their retentivity


Retentive data area (incl. timers, counters, flags), 768 kbyte
max.
Flag
● Number, max. 16 kbyte
● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte
Data blocks
● Retentivity adjustable Yes
● Retentivity preset No
Local data
● per priority class, max. 64 kbyte; max. 16 KB per block

Address area
Number of IO modules 8 192; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem

6ES7517-3HP00-0AB0 Subject to change without notice


Page 3/8 04/28/2020 © Copyright Siemens
— Inputs (volume) 16 kbyte
— Outputs (volume) 16 kbyte
Subprocess images
● Number of subprocess images, max. 32

Hardware configuration
Number of distributed IO systems 1
Number of IO Controllers
● integrated 1

Time of day
Clock
● Type Hardware clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● on Ethernet via NTP Yes

Interfaces
Number of PROFINET interfaces 2

1. Interface
Interface types
● Number of ports 2
● integrated switch Yes
● RJ 45 (Ethernet) Yes; X1
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device No
● SIMATIC communication Yes; Only Server
● Open IE communication Yes
● Web server No
● Media redundancy Yes; MRP Automanager according to IEC 62439-2 Edition 2.0
PROFINET IO Controller
Services
— PG/OP communication Yes
— S7 routing Yes
— Isochronous mode No
— IRT No
— MRP Yes; Only Manager Auto, max. 50 nodes

6ES7517-3HP00-0AB0 Subject to change without notice


Page 4/8 04/28/2020 © Copyright Siemens
— MRPD No
— PROFIenergy Yes
— Number of connectable IO Devices, max. 256
Update time for RT
— for send cycle of 1 ms 1 ms to 512 ms

2. Interface
Interface types
● Number of ports 1
● integrated switch No
● RJ 45 (Ethernet) Yes; X2
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller No
● PROFINET IO Device No
● SIMATIC communication Yes; Only Server
● Open IE communication Yes
● Web server No
● Media redundancy No

3. Interface
Interface type Pluggable interface module (IF)
Plug-in interface modules Synchronization module 6ES7960-1CB00-0AA5 or 6ES7960-
1FB00-0AA5

4. Interface
Interface type Pluggable synchronization submodule (FO)
Plug-in interface modules Synchronization module 6ES7960-1CB00-0AA5 or 6ES7960-
1FB00-0AA5

Interface types
RJ 45 (Ethernet)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
● Industrial Ethernet status LED Yes

Protocols
Number of connections
● Number of connections, max. 288
● Number of connections reserved for 10
ES/HMI/web
● Number of S7 routing paths 64
Redundancy mode
Media redundancy

6ES7517-3HP00-0AB0 Subject to change without notice


Page 5/8 04/28/2020 © Copyright Siemens
— MRP Yes; Manager Auto is permanently set in TIA. Max. 50 nodes are
possible
— MRPD No
— Switchover time on line break, typ. 200 ms; PROFINET MRP
— Number of stations in the ring, max. 50
SIMATIC communication
● S7 communication, as server Yes
● S7 communication, as client No
Open IE communication
● TCP/IP Yes
— Data length, max. 64 kbyte
— several passive connections per port, Yes
supported
● ISO-on-TCP (RFC1006) Yes
— Data length, max. 64 kbyte
● UDP Yes
— Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast
— UDP multicast Yes; Max. 5 multicast circuits
● DHCP No
● SNMP Yes
● DCP Yes
● LLDP Yes
Web server
● HTTP No
● HTTPS No
OPC UA
● OPC UA client No
● OPC UA server No
Further protocols
● MODBUS Yes; MODBUS TCP

Isochronous mode
Equidistance No

S7 message functions
Number of login stations for message functions, max. 64
Program alarms Yes
Number of configurable program messages, max. 10 000; Program messages are generated by the
"Program_Alarm" block, ProDiag or GRAPH
Number of loadable program messages in RUN, 5 000
max.
Number of simultaneously active program alarms
● Number of program alarms 1 000
● Number of alarms for system diagnostics 1 000

6ES7517-3HP00-0AB0 Subject to change without notice


Page 6/8 04/28/2020 © Copyright Siemens
Test commissioning functions
Joint commission (Team Engineering) No
Status block Yes; Up to 16 simultaneously
Single step No
Number of breakpoints 20; Breakpoints are only supported in RUN-Solo status
Status/control
● Status/control variable Yes
● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers,
counters
● Number of variables, max.
— of which status variables, max. 200; per job
— of which control variables, max. 200; per job
Forcing
● Forcing Yes
● Forcing, variables Peripheral inputs/outputs
● Number of variables, max. 200
Diagnostic buffer
● present Yes
● Number of entries, max. 3 200
— of which powerfail-proof 1 000
Traces
● Number of configurable Traces 8
● Memory size per trace, max. 512 kbyte

Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED Yes
● ERROR LED Yes
● MAINT LED Yes
● Connection display LINK TX/RX Yes

Supported technology objects


Motion Control No
Controller
● PID_Compact Yes; Universal PID controller with integrated optimization
● PID_3Step Yes; PID controller with integrated optimization for valves
● PID-Temp Yes; PID controller with integrated optimization for temperature
Counting and measuring Yes
● High-speed counter No

Ambient conditions
Ambient temperature during operation
● horizontal installation, min. 0 °C

6ES7517-3HP00-0AB0 Subject to change without notice


Page 7/8 04/28/2020 © Copyright Siemens
● horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50
°C, the display is switched off
● vertical installation, min. 0 °C
● vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature of typically 40
°C, the display is switched off
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see
manual

Configuration
Programming
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC No
— GRAPH Yes
Know-how protection
● User program protection/password protection Yes
● Copy protection No
● Block protection Yes
Access protection
● Password for display Yes
● Protection level: Write protection Yes
● Protection level: Read/write protection Yes
● Protection level: Complete protection Yes
Cycle time monitoring
● lower limit adjustable minimum cycle time
● upper limit adjustable maximum cycle time

Dimensions
Width 210 mm
Height 147 mm
Depth 129 mm

Weights
Weight, approx. 2 119 g; Interface modules: 2x 18 g

last modified: 04/28/2020

6ES7517-3HP00-0AB0 Subject to change without notice


Page 8/8 04/28/2020 © Copyright Siemens

You might also like