Model:KM2800
380 - 415V
Standard Features:
Rating Range • Kohler Co. provides one-source responsibility for the
generating system and accessories
KM2800
• The generator set and its components are prototyped-tested,
50Hz
factory-built and production tested
kW 2200 • The generator set complies with ISO8528-5, G3 requirement
Standby
kVA 2750 for transient performance
kW 2000 • A one-year limited warranty covers all systems and
Prime components.
kVA 2500
• 100% one step load
• MHI engine
• Marathon alternator
• Operation manual
Generator Rating
Standby Rating Prime Rating
Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps
MXL-2000-4 400 3 50 2200/2750 3969 2000/2500 3609
380 3 50 2200/2750 4178 2000/2500 3609
MXL-2000-4J
415 3 50 2200/2750 3826 2000/2500 3478
Alternator Specification
• NMEA MG1,IEEE and ANSI standards compliance for
temperature rise and motor starting Specification Alternator
• IP23 Manufacturer Marathon
• Insulation: Class H Type 4 Pole
• 2/3 Winding Pitch Leading Wire 6
Specification 50Hz AVR DVR2000E+
Voltage 400V Excitation system PMG
Standby (27℃),kVA 2750 Insulation/Temp rise H/H
Continuous (40℃), kVA 2625 Bearing Double
Efficiency (100% load) 95.5% Voltage regulation ±0.25%
Specification
Engine Engine Electrical
Engine Specification Engine electrical
Manufacturer Mitsubishi System Voltage (DC) 24
Model S16R2-PTAW2-E Battery ,CCA 4,1200
Engine Type Turbocharged Battery voltage (DC) 12
Cylinder 16V
Displacement, L 79.9 Lubrication
Bore and stroke, mm 170 x 220 Lubrication system
Compression ratio 14:1 Oil capacity (L) 200~260
Piston speed, m/s 11 Total Oil capacity (include filter) (L) 290
Rated speed (r/min) 1500 Min. oil pressure (bar) 2~3
Max standby power, kW 2430 Max. oil pressure (bar) 4~6
Governor Type Electrical
Frequency regulation ±0.25%
Air cleaner type Dry
Exhaust
Exhaust system
Exhaust flow at rated power, 𝑚3 /𝑚𝑖𝑛 506
Max back pressure, mm𝐻2 𝑂 600
Exhaust outlet size, mm See ADV
Controller
Specification
Cooling System
Cooling System
Ambient temperature (standby) ℃ 40
Decision-𝐌𝐚𝐫𝐤𝐞𝐫 𝐓𝐌 4000
Coolant capacity (only engine) L 190
Standard Feature
Coolant capacity (radiator), L 665 • Large LCD Display
Heat rejected to jacket water (kW) 960 • Unique control wheel for system access
Heat rejected to charge cooling water (kW) 692 • User buttons for start, stop, menu and escape
Fan diameter (mm) 2134 • Emergency stop button
• On/off key switch
Fan loss (kW) 100
• Panel-mounted battery fuse
Max. restriction of cooling air, intake and • Panel-mounted USB ports for PC access and software
150
discharge side of radiator (kPa) upgrade
Radiator cooling air flow 𝑚3 /𝑚𝑖𝑛 3300 • Password-protected access to control parameter
• Upgradeable software for future enhancements
LCD Panel Feature
Air requirement • 600 x 800 resolution
3
Combustion, 𝑚 /𝑚𝑖𝑛 191 • Multiple lines of text or graphic display
3 3 • Icons for quick identification of system status
Air Density =1.20 𝑘𝑔/𝑚 (0.075 𝑙𝑏/𝑓𝑡 )
• 6 language: Chinese, English, French, German,
Portuguese and Spanish
Fuel Consumption Communication Features
• Engine communication via CANbus
Diesel , L/h load% Standby
• Modus communication via RS485 or Ethernet
100% 586.1 • PC and flash drive connection via USB
Diesel , L/h load% Prime Function
100% 527.6 • View and adjust system operation parameters
• View system faults
75% 428.8
Viewable/Selectable Parameters (may require
50% 288.7 optional module)
25% 154.4 • Voltage/Current/Frequency
• Power (active/reactive/apparent)/Power factor
• Engine speed/Oil pressure/Coolant temperature/Battery
Voltage/Fuel level (%)/Time delays
Viewable Faults (over 60 individual faults are
monitored) including:
• Alternator protection
• Circuit breaker and grounding fault protection
• Communication and engine EMC monitor
• Cooling air monitoring
• Electrical charging system
• Engine cooling system
• Engine lube system
• Fuel system
• Generator set status
KOHLER CO., Kohler Power Systems
Kohler, Wisconsin 53044 USA 400 1808 900
Phone +1 (920)-565-3381 [email protected]
Kohler Power.com
Standard Configuration Dimension and weight
• Diesel engine
• Mechanical cooling system
• IP23 alternator:
- Space heater
- DVR2000E+
- PMG
- Winding PT100
- Rotor PT100
⚫ DEC4000 Controller (with battery charger)
L x W x H (mm): 7062 x 2859 x 3072
Option Dry weight (kg): 17550
• Coolant Heater Wet weight (kg): 18475
• Coolant and oil
• Spring isolator