Site Development Plan: G E N E R A L N O T E S 1 2 3 4
Site Development Plan: G E N E R A L N O T E S 1 2 3 4
1 ALL WORKS HEREIN SHALL CONFORM WITH THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (P.E.C.)
WITH THE REQUIREMENTS OF THE UTILITY COMPANIES CONCERNED AND WITH THE LOCAL GOVERNING GOVERNMENT AGENCY.
1 2 3 4 WIRING METHOD SHALL BE AS FOLLOWS:
2
12000
3 a: INTERMEDIATE METALLIC CONDUIT (IMC) - USED IN EXPOSED AND WET LOCATION OR IN HOLLOW PORTIONS OF CEILING OR WALLS.
9050 2950
4350 4700
b: POLYVINYL CHLORIDE (PVC) - USED WHEN EMBEDDED IN CONCRETE SLAB OR MASONRY ONLY, PROVIDE ADDITIONAL WIRE
SOLELY FOR GROUNDING, BONDING FOR GROUNDING, BONDING FOR ELECTRICAL CONTINUITY, USED FOR AUXILLIARY BRANCH CIRCUITS ONLY.
5150
4 WHEN NOT INDICATED IN THE DRAWING, SIZE OF RACEWAY SHALL BE 15mmØ. WIRES SHALL BE 3.5mmØ WITH INSULATION.
ALL WIRES SHALL BE RATED 600 VOLTS.
C 5 ADEQUATE AND EFFECTIVE GROUNDING OF EQUIPMENT SHALL BE PROVIDED.
6 WIRE DEVICES SHALL BE AS FOLLOWS:
a: WALL SWITCHES - 15 AMPS, 250 AMPS, FLUSH WALL MOUNTED.
4000
4750
b: DUPLEX RECEPTACLE - 15 AMPS, 250 VOLTS, FLUSH WALL MOUNTED.
ROOF DECK 2ND FLOOR
ROOFING ROOFING 7 ALL OUTLET BOXES SHALL BE PRESSED GALVANIZED STEEL "DEEP TYPE" GUAGE #16 AND WITH FACTORY KNOCKOUTS.
8 ALL POWER AND AUXILLLIARY LAYOUT ON AREAS WITH DROP CEILING SHALL NOT BE EMBEDDED ON CONCRETE SLAB. CONDUIT LAYOUT SHALL RUN
12000
B 1300 INSIDE CEILING OF THE NEXT FLOOR SLAB TO BE MORE FEASIBLE IN THE RELOCATION OF OUTLETS.
2350
9 MOUNTING HEIGHT SCHEDULE SHALL BE AS FOLLOWS:
a: CONVENIENCE, TELEPHONE, INTERCOM, MATV OUTLETS - 0.30 MTS. ABOVE.
3550
3850
ROOF DECK b: PANELBOARDS, TTC - 1.70 MTS. AT CENTER FROM FINISHED FLOOR LINE.
c: WALL SWITCHES - 1.37 MTS. AT CENTER FROM FLOOR FINISHED.
d: AIR CONDITIONING UNITS - VERIFY WITH THE ARCHITECTS.
A PANEL BOARD SHALL BE "QUICK MAKE" "QUICK BREAK" DEAD FRONT EQUIPPED WITH THE MAGNETIC TRIP INDICATING
10
Elev. +
MOLDED CASE CIRCUIT BREAKERS.
100mm
11 ALL ELECTRICAL WORKS HEREIN SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER.
ROAD LOT
Elev. +
0.00mm
L E G E N D S
1
SITE DEVELOPMENT PLAN INCANDESCENT LIGHT OUTLET INTERCOM OUTLET/INTERCOM FLOOR OUTLET
E1 SCALE 1: 100 METERS
SINGLE PHASE 2 X 36 WATTS FLOURESCENT FIXTURE, NORMAL/EMERGENCY SINGLE POLE SWITCH IN A GANG, FLUSH WALL MOUNTED
100 A
PB
WEATHER PROOF OUTLET TWO SINGLE POLE SWITCH IN A GANG, FLUSH WALL MOUNTED
REFRIDGERATOR OUTLET THREE SINGLE POLE SWITCH IN A GANG, FLUSH WALL MOUNTED
WASHING MACHINE OUTLET THREE WAY SWITCH IN A GANG, FLUSH WALL MOUNTED
2
VICINITY MAP 3
SERVICE ENTRANCE MANUAL TRANSFER SWITCH INTERMEDIATE DISTRIBUTION FRAME
[email protected] / (02) 215-9400 / +63 917 5528835 PTR : WALING-WALING ST. BRGY. TULO CALAMBA CITY LAGUNAGENERAL NOTES & LEGENDS DATE
Proposed Two Storey house
FILENAME : with Roofdeck.dwg