Thermostat Guard
Installation and Operation
#17149 – 10/1/17
Overview
The Thermostat Guard (Part # NSB-BG2) prevents tampering, physical damage, and unauthorized adjustment of
thermostats. It is made of thick, durable polycarbonate and features exceptional airflow, key lock protection, horizontal or
vertical mounting, and easy installation with hardware included.
.198” Diameter
Figure 1: Thermostat Guard Dimensions Mounting Hole Spacing: 3.76” x 4.02”
Mounting
1. Remove the Thermostat Guard’s cover from the mounting base.
To remove the cover, open the lock by rotating the key 1/4 turn
clockwise, open the cover about 15 degrees to the base and
push off to the “hinge” side.
2. Place the base over the device to be protected and mark for the
mounting holes.
3. Cover the device to be protected with a damp towel to prevent dust from
getting into the device.
4. Do one of the following:
For drywall, drill four 9/32-inch (7.1mm) holes. Insert the
anchors until they are flush with the wall surface. Attach the
base to the wall with the drywall screws (see Figure 2).
For concrete or cinder block, drill four 5/32-inch (4mm) holes,
1-3/4 inch (45mm) deep. Attach the base to the wall with the
concrete screws (see Figure 2).
NOTES
One key fits all Thermostat Guard locks.
You can remove the key from the Thermostat Guard only Figure 2: Thermostat Guard Mounting
when it is in the locked position.
Specifications subject to change without notice.
1150 Roberts Boulevard, Kennesaw, Georgia 30144
770-429-3000 Fax 770-429-3001 | www.automatedlogic.com 1 of 2
Thermostat Guard
Installation and Operation
#17149 – 10/1/17
Specifications
Material Impact resistant Polycarbonate Color Clear center w/ etched side wall
Construction Two piece Agency UL 94, V-0, RoHS
(Base and removable cover)
Mounting Hole
Venting 360º using base channels and Spacing 3.76” x 4.02” (95.6 x 102 mm)
multiple
Typical Thermostats Accommodated
1/4" ovals
Delta
Lock Key operated cylinder w/hook latch BAPI-Stat 2
Decora
Key Two keys included
PreCon
Mounting Four tabs in the base ring Siemens/Powers
Hardware Included 2-keys, Honeywell TB6980, TB7980, T6575, T8575,
Four #10-1.5" drywall screws TH5100, T87, TH3100, TH4100
Four #10-1.5" concrete screws JCI T4000, T22, T25, T26
Columbus Elec ET5, ETD5, UT8001 PECO
Cleaning Water dampened cotton T155, T158, T167, T168
cloth as needed Kele CDKW, TP1M, KTR, EXECUTIVE
(Other chemicals could affect the TAC/BC TK1000, TK5000, TK2200, 2212
sensor inside.) Vaisala - GE GMW – 5001
Maintenance None required.
(It may be worth checking the
mounting screws once a year for
tampering.)
Specifications subject to change without notice.