Modelcheck
Modelcheck
Pro/ENGINEER
Wildfire™ 2.0
ModelCHECK™
Help Topic Collection
Third-Party Trademarks
Adobe is a registered trademark of Adobe Systems. Advanced ClusterProven, ClusterProven, and the
ClusterProven design are trademarks or registered trademarks of International Business Machines
Corporation in the United States and other countries and are used under license. IBM Corporation does
not warrant and is not responsible for the operation of this software product. AIX is a registered
trademark of IBM Corporation. Allegro, Cadence, and Concept are registered trademarks of Cadence
Design Systems, Inc. Apple, Mac, Mac OS, and Panther are trademarks or registered trademarks of
Apple Computer, Inc. AutoCAD and Autodesk Inventor are registered trademarks of Autodesk, Inc.
Baan is a registered trademark of Baan Company. CADAM and CATIA are registered trademarks of
Dassault Systemes. COACH is a trademark of CADTRAIN, Inc. DOORS is a registered trademark of
Telelogic AB. FLEXlm is a trademark of Macrovision Corporation. Geomagic is a registered trademark
of Raindrop Geomagic, Inc. EVERSYNC, GROOVE, GROOVEFEST, GROOVE.NET,
GROOVE NETWORKS, iGROOVE, PEERWARE, and the interlocking circles logo are trademarks of
Groove Networks, Inc. Helix is a trademark of Microcadam, Inc. HOOPS is a trademark of Tech Soft
America, Inc. HP-UX is a registered trademark and Tru64 is a trademark of the Hewlett-Packard
Company. I-DEAS, Metaphase, Parasolid, SHERPA, Solid Edge, and Unigraphics are trademarks or
registered trademarks of Electronic Data Systems Corporation (EDS). InstallShield is a registered
trademark and service mark of InstallShield Software Corporation in the United States and/or other
countries. Intel is a registered trademark of Intel Corporation. IRIX is a registered trademark of Silicon
Graphics, Inc. LINUX is a registered trademark of Linus Torvalds. MatrixOne is a trademark of
MatrixOne, Inc. Mentor Graphics and Board Station are registered trademarks and 3D Design,
AMPLE, and Design Manager are trademarks of Mentor Graphics Corporation. MEDUSA and
STHENO are trademarks of CAD Schroer GmbH. Microsoft, Microsoft Project, Windows, the Windows
logo, Windows NT, Visual Basic, and the Visual Basic logo are registered trademarks of
Microsoft Corporation in the United States and/or other countries. Netscape and the Netscape N and
Ship's Wheel logos are registered trademarks of Netscape Communications Corporation in the U.S. and
other countries. Oracle is a registered trademark of Oracle Corporation. OrbixWeb is a registered
trademark of IONA Technologies PLC. PDGS is a registered trademark of Ford Motor Company. RAND
is a trademark of RAND Worldwide. Rational Rose is a registered trademark of Rational Software
Corporation. RetrievalWare is a registered trademark of Convera Corporation. RosettaNet is a
trademark and Partner Interface Process and PIP are registered trademarks of “RosettaNet,” a
nonprofit organization. SAP and R/3 are registered trademarks of SAP AG Germany. SolidWorks is a
registered trademark of SolidWorks Corporation. All SPARC trademarks are used under license and
are trademarks or registered trademarks of SPARC International, Inc. in the United States and in
other countries. Products bearing SPARC trademarks are based upon an architecture developed by Sun
Microsystems, Inc. Sun, Sun Microsystems, the Sun logo, Solaris, UltraSPARC, Java and all Java
based marks, and “The Network is the Computer” are trademarks or registered trademarks of Sun
Microsystems, Inc. in the United States and in other countries. TIBCO, TIBCO Software, TIBCO
ActiveEnterprise, TIBCO Designer, TIBCO Enterprise for JMS, TIBCO Rendezvous, TIBCO Turbo
XML, TIBCO Business Works are the trademarks or registered trademarks of TIBCO Software Inc. in
the United States and other countries. WebEx is a trademark of WebEx Communications, Inc.
Third-Party Technology Information
Certain PTC software products contain licensed third-party technology: Rational Rose 2000E is
copyrighted software of Rational Software Corporation. RetrievalWare is copyrighted software of
Convera Corporation. VisTools library is copyrighted software of Visual Kinematics, Inc. (VKI)
containing confidential trade secret information belonging to VKI. HOOPS graphics system is a
proprietary software product of, and is copyrighted by, Tech Soft America, Inc. G-POST is copyrighted
software and a registered trademark of Intercim. VERICUT is copyrighted software and a registered
trademark of CGTech. Pro/PLASTIC ADVISOR is powered by Moldflow technology. Moldflow is a
registered trademark of Moldflow Corporation. The JPEG image output in the Pro/Web.Publish module
is based in part on the work of the independent JPEG Group. DFORMD.DLL is copyrighted software
from Compaq Computer Corporation and may not be distributed. METIS, developed by George Karypis
and Vipin Kumar at the University of Minnesota, can be researched at
http://www.cs.umn.edu/~karypis/metis. METIS is © 1997 Regents of the University of Minnesota.
LightWork Libraries are copyrighted by LightWork Design 1990–2001. Visual Basic for Applications
and Internet Explorer is copyrighted software of Microsoft Corporation. Parasolid © Electronic Data
Systems (EDS). Windchill Info*Engine Server contains IBM XML Parser for Java Edition and the
IBM Lotus XSL Edition. Pop-up calendar components Copyright © 1998 Netscape Communications
Corporation. All Rights Reserved. TECHNOMATIX is copyrighted software and contains proprietary
information of Technomatix Technologies Ltd. Technology "Powered by Groove" is provided by Groove
Networks, Inc. Technology "Powered by WebEx" is provided by WebEx Communications, Inc. Oracle 8i
run-time and Oracle 9i run-time, Copyright © 2002–2003 Oracle Corporation. Oracle programs
provided herein are subject to a restricted use license and can only be used in conjunction with the PTC
software they are provided with. Apache Server, Tomcat, Xalan, and Xerces are technologies developed
by, and are copyrighted software of, the Apache Software Foundation (http://www.apache.org) – their
use is subject to the terms and limitations at: http://www.apache.org/LICENSE.txt. Acrobat Reader is
copyrighted software of Adobe Systems Inc. and is subject to the Adobe End-User License Agreement as
provided by Adobe with those products. UnZip (© 1990-2001 Info-ZIP, All Rights Reserved) is provided
“AS IS” and WITHOUT WARRANTY OF ANY KIND. For the complete Info-ZIP license see
ftp://ftp.info-zip.org/pub/infozip/license.html. Gecko and Mozilla components are subject to the Mozilla
Public License Version 1.1 at http://www.mozilla.org/MPL. Software distributed under the MPL is
distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY KIND, either expressed or implied.
See the MPL for the specific language governing rights and limitations. The Java™ Telnet Applet
(StatusPeer.java, TelnetIO.java, TelnetWrapper.java, TimedOutException.java), Copyright © 1996, 97
Mattias L. Jugel, Marcus Meißner, is redistributed under the GNU General Public License. This license
is from the original copyright holder and the Applet is provided WITHOUT WARRANTY OF ANY
KIND. You may obtain a copy of the source code for the Applet at http://www.mud.de/se/jta (for a
charge of no more than the cost of physically performing the source distribution), by sending e-mail to
[email protected] or [email protected]—you are allowed to choose either distribution method. The source code
is likewise provided under the GNU General Public License. GTK+The GIMP Toolkit are licensed
under the GNU LGPL. You may obtain a copy of the source code at http://www.gtk.org, which is
likewise provided under the GNU LGPL. zlib software Copyright © 1995-2002 Jean-loup Gailly and
Mark Adler. OmniORB is distributed under the terms and conditions of the GNU General Public
License and GNU Library General Public License. The Java Getopt.jar, copyright 1987-1997 Free
Software Foundation, Inc.; Java Port copyright 1998 by Aaron M. Renn ([email protected]), is
redistributed under the GNU LGPL. You may obtain a copy of the source code at
http://www.urbanophile.com/arenn/hacking/download.html. The source code is likewise provided under
the GNU LGPL. Mozilla Japanese localization components are subject to the Netscape Public License
Version 1.1 (at http://www.mozilla.org/NPL). Software distributed under NPL is distributed on an "AS
IS" basis, WITHOUT WARRANTY OF ANY KIND, either expressed or implied (see the NPL for the
specific language governing rights and limitations). The Original Code is Mozilla Communicator client
code, released March 31, 1998 and the Initial Developer of the Original Code is Netscape
Communications Corporation. Portions created by Netscape are Copyright © 1998 Netscape
Communications Corporation. All Rights Reserved. Contributors: Kazu Yamamoto
([email protected]), Ryoichi Furukawa ([email protected]), Tsukasa Maruyama ([email protected]),
Teiji Matsuba ([email protected]).
UNITED STATES GOVERNMENT RESTRICTED RIGHTS LEGEND
This document and the software described herein are Commercial Computer Documentation and
Software, pursuant to FAR 12.212(a)-(b) (OCT’95) or DFARS 227.7202-1(a) and 227.7202-3(a) (JUN’95),
is provided to the US Government under a limited commercial license only. For procurements
predating the above clauses, use, duplication, or disclosure by the Government is subject to the
restrictions set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software
Clause at DFARS 252.227-7013 (OCT’88) or Commercial Computer Software-Restricted Rights at
FAR 52.227-19(c)(1)-(2) (JUN’87), as applicable. 012304
Parametric Technology Corporation, 140 Kendrick Street, Needham, MA 02494 USA
Table Of Contents
ModelCHECK .................................................................................................. 1
Using ModelCHECK....................................................................................... 1
v
Table Of Contents
vi
Table Of Contents
vii
ModelCHECK
Using ModelCHECK
About ModelCHECK
ModelCHECK is an integrated application that runs transparently within
Pro/ENGINEER. ModelCHECK uses a configurable list of company design standards
and best modeling practices. It can be configured to run interactively as well as
automatically when you regenerate or save a model.
ModelCHECK:
• Analyzes parts, drawings, and assemblies.
• Presents the results of the analysis and recommends improvements in the form
of a dynamic HTML report. The ModelCHECK report appears in the browser
embedded in Pro/ENGINEER.
1
ModelCHECK - Help Topic Collection
• ModelCHECK Extension
o Pro/ENGINEER Foundation II
o Flexible Engineering
o Flexible Engineering II
To Start ModelCHECK
1. Start Pro/ENGINEER.
Note: You can limit or disable ModelCHECK with the MC_ENABLE configuration option
located in the config_init.mc file.
To Stop ModelCHECK
In Interactive mode of ModelCHECK, you can stop it by clicking the red stop button
in the lower-right corner of the Pro/ENGINEER window.
In Batch mode, use the Task Manager or kill the ModelCHECK process to stop
ModelCHECK.
2
ModelCHECK
this mode, ModelCHECK automatically runs every time you regenerate the model.
Problems are found immediately after they occur when they are easier to correct.
Determine which checks should run during Interactive mode by setting options in the
check configuration file.
In Part Mode
• Regenerates the model in the same way as when you click Utilities > Model
Player > Regenerate features > Finish in Pro/ENGINEER. This ensures that
the part can be fully regenerated and, if necessary, prints warning messages in
the ModelCHECK report.
Note: All the above part mode checks are run in ModelCHECK Regenerate. You
cannot choose to not run any of the above checks.
In Assembly Mode
Regenerates the top-level assembly and components as selected.
In Drawing Mode
• Regenerates all views in Drawing mode.
3
ModelCHECK - Help Topic Collection
• Reports any missing dimensional references (set the REGEN_DIM check in the
check configuration file).
• Performs all the checks for Part mode if you choose to run ModelCHECK
Regenerate on the drawing models.
Note: You should configure ModelCHECK to run only the most important checks in
Regenerate mode (such as buried feature check, children of rounds check) and not
the information checks. ModelCHECK then notifies you only when there is a critical
mistake.
Note: To ensure that the parameters ModelCHECK writes to the model are saved
with it, set the SAVE_MC_PRE option to Y.
In this method, ModelCHECK is run using a text file that has the list of models to
be checked. The procedure is different for the UNIX and Windows NT platforms.
The models to be checked must be stored on disk.
4
ModelCHECK
2. Create a text file in which you list the models you want checked. The text file
must have the .txt extension. There must be one model file name per line.
Note: You can also check a single model. In this case, a text file is not
necessary.
Note:
o To check a single model, omit the -f option. Specify the name of the model
or the path if it is in a different directory.
o If the start commands are unknown, specify the complete path of the shell
scripts to start ModelCHECK and Pro/ENGINEER. The shell scripts are in the
bin directory in the Pro/ENGINEER loadpoint. The default start commands
are modelcheck and proe, respectively. However, the names of the
commands can be customized during installation. The names of the
commands are generally the same as the names of the shell scripts.
<proengineer-loadpoint>/bin/modelcheck <proengineer-
loadpoint>/bin/proe -f <file>.txt
4. In the summary report, click a listed model name to see that model’s
ModelCHECK report.
ModelCHECK checks the four named models and creates reports for each one.
5
ModelCHECK - Help Topic Collection
Note: Alternatively, run the batch file for ModelCHECK from the bin directory in
the Pro/ENGINEER loadpoint to start ModelCHECK. The default batch file for
ModelCHECK is modelcheck.bat.
2. Select the model on which you want to run ModelCHECK or select a text file that
specifies a list of file names.
Note: If the command to start Pro/ENGINEER is not known, browse to the bin
directory in the Pro/ENGINEER loadpoint and run the batch file to start
Pro/ENGINEER. The default batch file is proe.bat, but a different name can be
specified during installation.
Note: From a DOS window, you can create a file called parts.lst that contains all
Pro/ENGINEER models from a specified directory. To do this, type the following
command:
dir *.prt.* *.asm.* *.drw.* /b > parts.lst
3. Select the models to be checked or select a text file, or files, having the list of
models to be checked.
4. Choose whether you want ModelCHECK to run on the current computer or across
several computers.
Note: To run ModelCHECK across several computers, each computer must have a
ModelCHECK and Pro/ENGINEER license. If a computer does not have a license,
6
ModelCHECK
5. Run the batch process. ModelCHECK generates and writes reports for each model
to the specified directory.
6. In your Web browser, browse to the required ModelCHECK report file and open it.
The report is similar to the report generated in Interactive mode.
See the Distributed Pro/BATCH Help for details about running ModelCHECK from
Distributed Pro/BATCH.
• Creates layers
• Fully regenerates the model from the first feature and reports any problems
• Renames datums
• Renames layers
These corrections are performed in the ModelCHECK Batch mode as well as when
ModelCHECK is run through Distributed Pro/BATCH. ModelCHECK automatically
checks a corrected model a second time to update the reports and save the model.
Note: If ModelCHECK is run in Batch mode, a Pro/ENGINEER license is required,
because the models must be accessed in Pro/ENGINEER.
Configuring ModelCHECK
7
ModelCHECK - Help Topic Collection
You can also configure ModelCHECK to report problems using the PTC ModelCHECK
Configuration Tool dialog box.
The following text files store the configuration options:
• config_init.mc (initialization file)
In addition, the following text files store the values required while checking models:
• <filename>.txt (external file)
• Select items from boxes to set options in the ModelCHECK configuration files.
• See the help for the configuration files on the top of the right pane and the
details of the configuration options in the bottom pane.
To Configure ModelCHECK
1. Click Analysis > ModelCHECK > Configure ModelCHECK. The PTC
ModelCHECK Configuration Tool dialog box opens.
2. Use the PTC ModelCHECK Configuration Tool dialog box to set the options in
the ModelCHECK configuration files.
Note:
8
ModelCHECK
• The system administrator can limit access to the configuration files using file
permissions. The PTC ModelCHECK Configuration Tool recognizes the
permissions and does not allow unauthorized access to the configuration files.
• Changes to the configuration files are not effective unless you save the files.
o MODEL_CHECK—(string) The date and time that ModelCHECK was last run.
9
ModelCHECK - Help Topic Collection
Note: You can see but not change the values of these parameters.
You can then program Pro/INTRALINK to allow the check-in of only those models
with the previous parameters set to specified values. For example, you can write
a trigger to deny the check-in of models with errors (MC_ERRORS is greater than
0.)
10
ModelCHECK
2. Click Edit config_init.mc. A table listing all the configuration options in the
config_init.mc file and their values appears in the right pane of the PTC
ModelCHECK Configuration Tool dialog box. The configuration options are
divided into three sections according to the values to which you can set the
options.
3. Edit the configuration options and their values using the boxes.
You can add and delete rows to add and delete configuration options,
respectively.
4. Click Save.
Note: Changes to the config_init.mc file are not effective in the current
Pro/ENGINEER session. Restart Pro/ENGINEER.
2. Set the options to a value for each ModelCHECK mode. Each mode is in a
separate column. The modes are abbreviated as follows:
o I—Interactive
o B—Batch
o R—Regenerate
o S—Save
Note: You can use spaces in the name of a directory without enclosing it in
quotes.
<Y/N/A>
11
ModelCHECK - Help Topic Collection
Creates a parameter called MC_CONFIG in all models that are checked. This
parameter contains the names of the ModelCHECK configuration files used for a
final check of the model.
• ADD_DATE_PARM
<Y/N>
Creates a parameter called MODEL_CHECK in the model files of all models that are
checked. This parameter contains the date and time when ModelCHECK was last
run.
• ADD_DUP_INFO_AUTO
<Y/N/A/D>
o D—Adds the model information but does not overwrite the existing
information.
• ADD_ERR_PARM
<Y/N>
Creates a parameter called MC_ERRORS in all models that are checked. This
parameter contains the number of errors found in the model when ModelCHECK
was last run.
• ADD_MODE_PARM
<Y/N/A>
Creates a parameter called MC_MODE in all models that are checked. This
parameter contains the mode in which ModelCHECK was run on the model.
12
ModelCHECK
• ASM_BATCH_ALL
<Y/N>
• ASYNC_PORT
<integer>
ModelCHECK opens this port when Pro/ENGINEER is started. This port remains in
use for the duration of the session.
If during startup ModelCHECK detects another process using the default port, it
increases the port number by 10 and tries again. ModelCHECK repeats this
procedure 5 times before displaying an error message and disabling Java.
• BURIED_ADVANCED
<Y/N>
• CHECK_ALL_MODELS
<Y/N>
• DIR_REPORT
<directory path>
13
ModelCHECK - Help Topic Collection
• DIR_REPORT_NT
<directory path>
• DIR_REPORT_U
<directory path>
• DIR_MC_DUP_READ
<directory path>
Specifies the path to a directory from which duplicate model information is read.
ModelCHECK reads a file called mc_dup_model.bin from this location. The
directory specified by the DIR_MC_DUP_READ configuration option should be a
common directory for all users.
Reuse this option up to 50 times to specify more than one location to read from.
Use a new line for every location.
• DIR_MC_DUP_READ_NT
<directory path>
• DIR_MC_DUP_READ_U
<directory path>
14
ModelCHECK
Specifies the path on UNIX to a directory from which duplicate model information
is read. If this option is not set, the DIR_MC_DUP_READ configuration option is
used.
• DIR_MC_DUP_WRITE
<directory path>
ModelCHECK writes a file called mc_dup_model.bin to this location when you exit
Pro/ENGINEER.
• DIR_MC_DUP_WRITE_NT
<directory path>
• DIR_MC_DUP_WRITE_U
<directory path>
• DIR_MC_PREVIEW_NT
<directory path>
• DIR_MC_PREVIEW_U
<directory path>
Specifies the path on UNIX to a directory in which the temporary files created by
the preview process are stored. If this option is not set, the DIR_MC_PREVIEW
configuration option is used.
• DIR_MC_PREVIEW
<directory path>
15
ModelCHECK - Help Topic Collection
Specifies the path to a directory in which the temporary files created by the
preview process are stored. The default path is c:\Temp (Windows NT) or /tmp
(UNIX).
• DIR_METRICS
<directory path>
Specifies the path to a directory in which metrics flat files are written. The
directory specified by the DIR_METRICS configuration option should be a common
directory for all users, for easy compilation and management of the flat files.
For performance reasons, the flat file is initially written to the directory specified
by the DIR_REPORT configuration option and is moved to the directory specified
by the DIR_METRICS configuration option when you exit Pro/ENGINEER.
• DIR_METRICS_NT
<directory path>
Specifies the path on Windows NT to a directory in which metrics flat files are
written. If this option is not set, the DIR_METRICS configuration option is used.
• DIR_METRICS_U
<directory path>
Specifies the path on UNIX to a directory in which metrics flat files are written. If
this option is not set, the DIR_METRICS configuration option is used.
• DRW_SHEET_ALL
<Y/N/A>
• HIGHLIGHT_COLOR
<Yellow/White/Gray/Blue/Red/Magenta/Cyan/Green/Brown>
16
ModelCHECK
• HTML_FILE_OUTPUT
<Y/N>
Creates HTML-based summary reports and writes them to the directory specified
by the DIR_REPORT configuration option.
• HTML_MAX_DAYS
<Integer>
Specifies the maximum number of days that ModelCHECK reports are kept.
If the HTML_MAX_DAYS configuration option is not specified, the purge is not done.
• ILNK_MC_DUP_FLDR
<directory path>
Specifies the complete path to the folders that the mcilchkout application must
search for duplicate models.
Reuse this option up to 50 times to search more than one folder. Use a new line
for every folder as follows:
o ILNK_MC_DUP_FLDR <root_dir>/<dir1>
o ILNK_MC_DUP_FLDR <root_dir>/<dir2>
• ILNK_MC_PRVW_SCRPT
<path>
Specifies the path to the Pro/INTRALINK TOOLKIT execution script (in the bin
directory of the Pro/INTRALINK TOOLKIT loadpoint) to execute the mcilchkout
application. The mcilchkout application allows duplicate models in the
Pro/INTRALINK Commonspace to be previewed from the ModelCHECK report.
• ILNK_MC_SRCH_SCRPT
<path>
Specifies the path to the Pro/INTRALINK TOOLKIT execution script (in the bin
directory of the Pro/INTRALINK TOOLKIT loadpoint) to execute the mcilsearch
application. The mcilsearch application searches for duplicate models.
• INTRALINK_DUPINFO
<Y/N>
17
ModelCHECK - Help Topic Collection
o N—Stores the shape information for models in a place other than the
Pro/INTRALINK Commonspace.
• MC_ENABLE
<Y/N/A>
o N—Disables ModelCHECK.
• MC_METRICS
<Y/N>
Specifies whether ModelCHECK must generate metrics files for use in the metrics
package.
• MC_VDA_RUN
<Y/N>
• MODE_RUN
<Y/N>
Specifies the operating mode in which ModelCHECK will run. Set to Y to run and
to N to turn ModelCHECK off in each mode.
• MODE_UPDATE
<Y/N>
Sets ModelCHECK to allow updating of wrong or missing features. For this option
to work properly, your browser must support Java. You can then update these
features from the ModelCHECK report.
In Batch mode, corrections are automatically made to models, and the models
are saved. In other modes, you must save the models after changes have been
made.
• PARENT_HI_COLOR
18
ModelCHECK
<Yellow/White/Gray/Blue/Red/Magenta/Cyan/Green/Brown>
Highlights parent objects in Pro/ENGINEER using the specified color. This option
is used only when ModelCHECK simultaneously highlights a problematic feature
and its parents.
• PROGRAM
Specifies the command to start Pro/ENGINEER. This option is used only in Batch
mode.
• SAVE_MC_PRE
<Y/N>
Set this option to N if you are concerned about data loss. In the unlikely
event that ModelCHECK causes Pro/ENGINEER to exit prematurely, this
ensures that models are saved before Pro/ENGINEER exits prematurely.
• SHOW_REPORT
<Y/N>
• SKIP_MODELS
<Y/N>
Specifies whether ModelCHECK must skip the checking of models that have not
changed after they were retrieved.
o N—Skips checking the model only if the value of the MC_ERRORS parameter
is 0 and the model has not changed after retrieval. This is the default.
19
ModelCHECK - Help Topic Collection
The config_init.mc file is formatted in six columns: The name of the option
(MODE_RUN for example), the values you can set it to (YN for example), the value it is
set to in interactive (I), batch (B), regenerate (R), and save (S) modes.
! ----------------------------------------------------------
# Options "I" "B" "R" "S"
! ----------------------------------------------------------
# Enable ModelCHECK Y=enable, N=disable, A=Ask user
MC_ENABLE YNA Y
# Enable/Disable ModelCHECK in specific modes
MODE_RUN YN Y Y N N
# Automatically update errors in models when run in BATCH
MODE_UPDATE YN Y Y Y Y
# Enable/Disable ModelCHECK metrics in specific modes
MC_METRICS YN Y Y Y Y
# Directory ModelCHECK will write reports on NT
#DIR_REPORT_NT $TEMP/mc_reports
# Directory ModelCHECK will write reports on UNIX
DIR_REPORT_U /tmp/mc_reports
# Directory ModelCHECK will write reports
#DIR_REPORT $TEMP/mc_reports
# Directory ModelCHECK will write metrics flat file on NT
#DIR_METRICS_NT $TEMP/mc_metrics
# Directory ModelCHECK will write metrics flat file on UNIX
DIR_METRICS_U /tmp/mc_metrics
# Directory ModelCHECK will write metrics flat file
#DIR_METRICS $TEMP/mc_metrics
# Directory ModelCHECK will read shape indexing files on NT
DIR_MC_DUP_READ_NT $TEMP/mc_dup_read
# Directory ModelCHECK will read shape indexing files on UNIX
DIR_MC_DUP_READ_U /tmp/mc_dup_read
# Directory ModelCHECK will read shape indexing files
DIR_MC_DUP_READ $TEMP/mc_dup_read
# Directory ModelCHECK will write shape indexing files on NT
#DIR_MC_DUP_WRITE_NT $TEMP/mc_dup_write
# Directory ModelCHECK will write shape indexing files on UNIX
DIR_MC_DUP_WRITE_U /tmp/mc_dup_write
# Directory ModelCHECK will write shape indexing files
#DIR_MC_DUP_WRITE $TEMP/mc_dup_write
# Asyncronous port for ModelCHECK server to use
ASYNC_PORT 3001
# Number of days to save html and xml files in DIR_REPORT
HTML_MAX_DAYS 1
# Auto add/upd parameter MODEL_CHECK to model with current date as it's
value
ADD_DATE_PARM YN N N N N
# Auto add/upd parameter MC_ERRORS to model with number of errors found
in model
ADD_ERR_PARM YN N N N N
20
ModelCHECK
21
ModelCHECK - Help Topic Collection
• Model units
• Number of features
• Number of datums
Click in the ModelCHECK report to see the selected model without having to open
it in Pro/ENGINEER. You can also spin, pan, and zoom the model in the preview
window.
2. Create a file with a list of all the files to be combined with the mc_dup_model.bin
file using one of the following commands:
22
ModelCHECK
where z is used to zoom or change the default value of the search criteria.
ModelCHECK uses a number of shape indexing parameters to compare models to
one another. Two models are considered similar if the values of their
corresponding parameters are within a specific percentage of each other. This
percentage is called the search criteria. The value of the search criteria is 5% by
default.
4. Specify a value for the search criteria. The maximum value is 10%.
Note: If you type a new value for the search criteria, the old value is multiplied
by the new value. If -z is not used in the merge command, you cannot enter a
new value and the existing value is used.
23
ModelCHECK - Help Topic Collection
When a model is saved, these parameters store the shape attributes. These
parameters are automatically stored as versioned object attributes in the
Pro/INTRALINK Commonspace when you check in the model.
Note: The Pro/INTRALINK Database Administrator must create the versioned
attributes of type string with no default values and also give permissions to change
the values.
ModelCHECK uses the versioned or life-cycle (for legacy parts) shape attributes
stored in the Commonspace to search for duplicate models. You can specify the
tolerance percentage for the attributes using options in the constant configuration
file. Only those models with all the attributes within the tolerance range are
considered as duplicate models and are reported.
For models with family tables, the parameters MC_SI1 through MC_SI7 are added to
the family table when ModelCHECK is run on the generic model. For the shape
information of all instances to be available in the Pro/INTRALINK Commonspace, you
must verify the family table before checking the model into Pro/INTRALINK.
Note: Family table verification changes the model resulting in a new version of the
model in Pro/INTRALINK.
mcilupdLCA.sh (UNIX) or
24
ModelCHECK
or
set PDM_USER=<Intralink_user>
set PDM_PASSWD=<Intralink_passwd> (Windows NT)
For example:
o On Windows NT, add the following lines to the mcilupdLCA.bat batch file:
set PDM_USER=INTRALINK
set PDM_PASSWD=INTRALINK
<Pro/ENGINEER_load_point>/<machine_type>/obj/mcilupdLCA $* (UNIX) or
<Pro/ENGINEER_load_point>\<machine_type>\obj\mcilupdLCA.exe %1 %2
(Windows NT)
Note: On Windows NT, you must add the above line just before :ptc_end.
For example:
<Pro/ENGINEER_load_point>/sun4_solaris/obj/mcilupdLCA $*
o On Windows NT, add the following line to the mcilupdLCA.bat batch file:
<Pro/ENGINEER_load_point>\i486_nt\obj\mcilupdLCA.exe %1 %2
4. Specify the name of the Workspace where you have checked out the legacy
models and have run ModelCHECK on them, as the argument to the script.
This updates the life-cycle attributes in the Pro/INTRALINK Commonspace for the
checked-out versions.
Note: Do not checkin the legacy models as this creates a new version. Instead,
delete them from the Workspace.
25
ModelCHECK - Help Topic Collection
mcilsearch.sh (UNIX) or
or
set PDM_USER=<Intralink_user>
set PDM_PASSWD=<Intralink_passwd> (Windows NT)
For example:
o On Windows NT, add the following lines to the mcilsearch.bat batch file:
set PDM_USER=INTRALINK
set PDM_PASSWD=INTRALINK
<Pro/ENGINEER_load_point>/<machine_type>/obj/mcilsearch $* (UNIX) or
<Pro/ENGINEER_load_point>\<machine_type>\obj\mcilsearch.exe %1 %2 %3
(Windows NT)
Note: On Windows NT, you must add the above line just before :ptc_end.
For example:
<Pro/ENGINEER_load_point>/sun4_solaris/obj/mcilsearch $*
o On Windows NT, add the following line to the mcilsearch.bat batch file:
<Pro/ENGINEER_load_point>\i486_nt\obj\mcilsearch.exe %1 %2
26
ModelCHECK
mcilchkout.sh (UNIX) or
or
set PDM_USER=<Intralink_user>
set PDM_PASSWD=<Intralink_passwd> (Windows NT)
For example:
o On Windows NT, add the following lines to the mcilchkout.bat batch file:
set PDM_USER=INTRALINK
set PDM_PASSWD=INTRALINK
<Pro/ENGINEER_load_point>/<machine_type>/obj/mcilchkout $* (UNIX) or
<Pro/ENGINEER_load_point>\<machine_type>\obj\mcilchkout.exe %1 %2
(Windows NT)
Note: On Windows NT, you must add the above line just before :ptc_end.
For example:
27
ModelCHECK - Help Topic Collection
<Pro/ENGINEER_load_point>/sun4_solaris/obj/mcilchkout $*
o On Windows NT, add the following line to the mcilchkout.bat batch file:
<Pro/ENGINEER_load_point>\i486_nt\obj\mcilchkout.exe %1 %2
2. Click Edit setconf.mcc. A table listing all the sets of configurations appears in
the right pane of the PTC ModelCHECK Configuration Tool dialog box. Each
set comprises a name and the combination of start, check, constant, and status
configuration files.
o Add and delete rows to add and delete sets, respectively. To add sets, type
the name of the set.
o Add columns to specify more than one start, check, constant,and status
configuration files.
4. Click Save.
28
ModelCHECK
1. Open the setconf.mcc file using a text editor. This file is located in
<proengineer-loadpoint>/modchk/text/<language>/config or in the directory
that you specify with the $MCDIR environment variable. Edit the file to set the
configurations. For example:
PDM=(checks/pdm.mch)(start/pdm.mcs)(constant/pdm.mcn)(status/pdm.mcq)
Light=(checks/simple_checks.mch) (start/default_start.mcs)
(constant/mm.mcn) (status/default_status.mcq)
NoStart=(checks/default_checks.mch) (start/nostart.mcs)
(constant/mm.mcn) (status/default_status.mcq)
2. Save the setconf.mcc file. All the configuration files you list in this file must be
in their respective directories.
2. Click Edit condition.mcc. A table listing all the conditions appears in the right
pane of the PTC ModelCHECK Configuration Tool dialog box. The check box
for each condition allows you to specify whether ModelCHECK should evaluate the
condition or treat it as a comment.
3. In the Choose View box, select Conditions to edit the SET CONFIG FILE section
of the condition.mcc file.
29
ModelCHECK - Help Topic Collection
4. Edit the conditions and the combination of configuration files for each condition
using the boxes.
Note: The PTC ModelCHECK Configuration Tool dialog box only displays
conditions with a ! mark in the condition.mcc file. Comments can also be
indicated with a # mark if you manually edit the condition.mcc file.
However, the PTC ModelCHECK Configuration Tool dialog box does not
display conditions with a # mark.
6. In the Choose View box, select Override to edit the OVERRIDE CHECKS section
of the condition.mcc file.
9. Click Save.
2. Specify the conditions and the combination of configuration files for each
condition.
30
ModelCHECK
31
ModelCHECK - Help Topic Collection
# OVERRIDE CHECKS
IF (NOCHECK) NOCHECK
IF (MODEL_SIZE EQ large) SHARP_EDGES = No
IF (MODEL_SIZE EQ large) SRF_EDGES = No
IF (MODEL_SIZE EQ large) SLA_INFO = No
IF (DRAWN_BY EQ John Wallace) MODEL_NAME = Error
• NEQ—not equal to
• GT—greater than
• LT—less than
Each IF statement can have one or more equalities. If there are several equalities,
they are separated by AND statements. Following the equality statements on each
line is the list of files that are read to form a configuration.
Item Name
32
ModelCHECK
table FT_INSTANCE_ASM
• ?—One character
• PRT_SHEETMETAL
• PRT_SKELETON
• PRT_PIPE
• PRT_HARNESS
• ASM_DESIGN
• ASM_INTERCHANGE
• ASM_MOLD_LAYOUT
Note: If you have more than one condition for part types, the first condition that is
satisfied is applied. Models can satisfy more than one condition (for example, a pipe
is also a solid), which makes the order of conditions in the condition.mcc file very
important.
About Groups
Users can be assigned to groups, and specific configuration files can be loaded for
users depending on the group they belong to. In the condition.mcc file, groups are
specified using the syntax:
IF (GROUPNAME EQ name_of_group) config=
33
ModelCHECK - Help Topic Collection
To Set Up the Group Files Using the PTC ModelCHECK Configuration Tool
1. Click adjacent to Group Files in the left pane of the PTC ModelCHECK
Configuration Tool dialog box.
2. Select the required group file. A table listing the contents of the file appears in
the right pane of the PTC ModelCHECK Configuration Tool dialog box.
3. Edit the contents using the boxes. You can add and delete rows as required.
4. Click Save or Save as to save your changes to the current or a different file,
respectively.
34
ModelCHECK
You can combine several start files into a single configuration. This allows you to
have a standard list of start part items that are in all models while giving
departments the opportunity to have a set of their own start part items in addition to
the company standard ones.
If there is duplicate information in the start files, the configuration file listed last is
used. Consider the sample condition.mcc file where the start_standard.mcs and
start_gavin.mcs files are listed on the same line. If the start_standard file
contains the line:
PRT_PARAMETER WIDGET STR EQ GREEN
and if the start_gavin file contains the following line:
PRT_PARAMETER WIDGET STR EQ BLUE
then the line from the start_standard file is ignored. That line conflicts with the line
from the start_gavin file and the line from the start_standard file comes before
the line from the start_gavin file.
Runs the listed configuration files if the user’s login name is finn.
Runs the listed configuration files if the user’s login name is gavin and the model
units are set to inches.
Runs the listed configuration files if the user’s login name is gavin and the model
units are set to metric.
Runs the listed configuration files if the user belongs to the CHECKER group.
Runs the listed configuration files if the name of the model starts with ec.
35
ModelCHECK - Help Topic Collection
Runs the listed configuration files if the model is a sheet metal part.
Runs the listed configuration files if the model is a generic part and its units are
mm.
Runs the listed configuration files if the model is an instance of a family table and
the model units are metric.
Runs the listed configuration files if the model has been created after the
specified date.
Runs the listed configuration files if the model has been last saved in a
Pro/ENGINEER version, later than the specified version.
Runs the listed configuration files if a parameter called NOSTART is found in the
model.
Runs the listed configuration files if the units of the model are inches.
Runs the listed configuration files if the units of the model are inches.
Runs the default configuration files if none of the above conditions are true.
36
ModelCHECK
In the OVERRIDE CHECKS section of the condition.mcc file, specific checks can be
overridden under certain conditions. This section contains a series of IF statements.
When ModelCHECK runs, it reads this list from the file and applies all the statements
that are correct.
o IF (SPECIFIC) NOCHECK
If the model name begins with 123, skip checking the model.
If the model units are neither millimeters nor inches, skip checking the
model.
Note: Parameter names and values are case sensitive. If you want ModelCHECK to
accept both uppercase and lowercase versions of a parameter, specify them on two
separate lines.
37
ModelCHECK - Help Topic Collection
3. Select the required check file. A table listing the checks and their values appears
in the right pane of the PTC ModelCHECK Configuration Tool dialog box.
Note: Click Create new file to create a new check configuration file.
ModelCHECK dynamically updates all boxes listing check configuration files in the
PTC ModelCHECK Configuration Tool dialog box with the name of the new file.
5. In the Check type to view box, select the type of check. All checks of the
selected type are listed in the table. ModelCHECK dynamically updates the boxes
in the table to only list checks of the selected type.
You can add and delete rows to add and delete checks, respectively.
7. Click Save or Save as to save your changes to the current or a different file,
respectively.
2. Set a value for the Interactive (I), Batch (B), Regenerate (R), and Save (S)
modes for each check. The values for each check are:
o Y—Performs the check and lists the results but does not report any
problems in the ModelCHECK report. Use Y for minor problems or for
information-only checks.
o E—Performs the check and reports an error if it fails. Errors are reported in
the ModelCHECK report. When errors are found, a model parameter is
created that has a value of the number of errors found in the model. A PDM
system can be set to track models with errors or to even reject their
submission. Use E for the most serious problems.
38
ModelCHECK
Note: If you see a check that does not apply to your site, turn the check off by
setting it to N in all modes.
Y/N/E/W
Reports the type of accuracy (relative or absolute) and its value. It also reports
whether the value set is within an acceptable range. The acceptable limits are set
using the following constant configuration options:
Note: Pro/ENGINEER fully regenerates the model if you change the type or value
of the accuracy.
Suggested Settings:
W W W W
Y/N
Adds or updates a parameter in the model that stores the outcome of another
check. The PRT_ADD_CHK_PARAM, ASM_ADD_CHK_PARAM, and DRW_ADD_CHK_PARAM
configuration options in the start configuration file are used to specify the
parameters to create.
Examples of where parameters can be used include material name, model name,
or model units.
Note: When this check is enabled, parameters are automatically updated and
created as necessary when running ModelCHECK.
Suggested Settings:
39
ModelCHECK - Help Topic Collection
Y Y N Y
Y/N/E/W
Reports any buried features in the model. If any are found, you can highlight
them in the Pro/ENGINEER window. Buried features are completely enveloped by
another feature.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Reports any features that are children of chamfers. If any are found, you can
highlight them in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Checks for the existence of a set of standard named features. If they are found,
ModelCHECK checks for the existence of standard named children.
If the parent features do not exist in the model, ModelCHECK does not check for
the children.
Parent features and their children are listed using the PRT_CHILD_EXIST and
ASM_CHILD_EXIST configuration options.
Suggested Settings:
E E E E
40
ModelCHECK
Y/N
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
Y Y N N
Y/N/E/W
Reports any circular cuts or slots in the model that could have been modeled
using holes instead. If any are found, you can highlight the features in question
in the Pro/ENGINEER window. This check ignores cylindrical features that have
been created using the Revolve command.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
W W W W
Y/N/E/W
Reports any circular cuts in the model without standard diameters. If any are
found, you can highlight the features in question in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
41
ModelCHECK - Help Topic Collection
If this check is enabled and a specified datum is found in the model, ModelCHECK
renames it as specified. Datum names to be renamed are specified using the
PRT_DATUM_RENAME and ASM_DATUM_RENAME start configuration options.
Suggested Settings:
W W N W
Y/N/E/W
Checks that the model’s density is not the default (1.00). If it is the default,
update the density from the ModelCHECK report.
Suggested Settings:
Inter Batch Regen Save
W W N E
Y/N
Reports the number of features that are direct children of the default datum
planes.
Suggested Settings:
Y Y N N
Y/N/E/W
Suggested Settings:
N N N N
Y/N/E/W
42
ModelCHECK
Suggested Settings:
N N N N
Y/N/E/W
Reports whether any draft features in the model do not have standard draft
angles. If any are found, you can highlight the features in question in the
Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Lists the features that are children of draft features. If any are found, you can
highlight them in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N
Suggested Settings:
Y Y N N
43
ModelCHECK - Help Topic Collection
Y/N
Suggested Settings:
Y Y N N
Y/N
Suggested Settings:
Y Y N N
Y/N
Suggested Settings:
Y Y N N
Y/N
Suggested Settings:
Y Y N N
Y/N/E/W
Lists the models in your shape indexing database that are similar in shape to the
model being checked.
Suggested Settings:
44
ModelCHECK
W W W W
Y/N/E/W
Lists the chamfers in the early features of the model. Early features appear within
a specified percentage of all the features in the model starting from the top of the
Model Tree. The percentage is defined by the PERC_EARLY_CHAMF start
configuration option.
If any are found, you can highlight the features in question in the Pro/ENGINEER
window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Lists cosmetic features in the early features of the model. Early features appear
within a specified percentage of all the features in the model starting from the
top of the Model Tree. The percentage is defined by the PERC_EARLY_COSMETIC
start configuration option.
If any are found, you can highlight them in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
W W W W
Y/N/E/W
Lists the drafts in the early features of the model. Early features appear within a
specified percentage of all the features in the model starting from the top of the
Model Tree. The percentage is defined by the PERC_EARLY_DRAFT start
configuration option.
If any are found, you can highlight the features in question in the Pro/ENGINEER
window.
45
ModelCHECK - Help Topic Collection
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Lists rounds in the early features of the model. Early features appear within a
specified percentage of all the features in the model starting from the top of the
Model Tree. The percentage is defined by the PERC_EARLY_ROUND start
configuration option.
If any are found, you can highlight the features in question in the Pro/ENGINEER
window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Lists features that have been created using edges as dimension reference points.
If any are found, you can highlight them in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
Lists all the external dependencies of a model. The names of the assemblies in
which the external dependencies exist are also listed. You can highlight the
external dependencies.
Note: If the referenced models are not in the current session, a corresponding
message appears.
46
ModelCHECK
Suggested Settings:
Y N Y N
Y/N/E/W
Lists any extra layers in the model. Extra layers are not listed in the start part.
If any are found, you can highlight the features in question in the Pro/ENGINEER
window.
Suggested Settings:
W W W W
Y/N/E/W
Reports extra parameters in the model. Extra parameters are not listed in the
start part. If any are found, you can highlight the features in question in the
Pro/ENGINEER window.
Suggested Settings:
W W W W
Y/N/E/W
Identifies a model as either generic or not. If the model is generic, this check
reports the instances with their names, and whether the instances have been
successfully verified.
Not verified—Not verified because one or more of the following cases is true.
o The geometry of the generic model has changed after the family table was
last verified.
47
ModelCHECK - Help Topic Collection
o A new item has been added to the family table after the family table was
last verified.
Suggested Settings:
W W N N
Y/N
Suggested Settings:
Y Y N N
Y/N
Suggested Settings:
Y Y N N
Y/N/E/W
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
Y Y N N
Y/N/E/W
If the model has a family table, this check makes sure that no instances have
default values (there are no asterisks (*) in the table).
48
ModelCHECK
If this is the case, the ModelCHECK report allows you to convert all asterisks to
their corresponding values as specified in the generic.
Suggested Settings:
W W N N
Y/N/E/W
Ensures that the standard parameters have been added to models with family
tables. Standard parameters are set in the start configuration file using the
PRT_FT_PARAMETER and ASM_FT_PARAMETER configuration options.
Suggested Settings:
W W W W
Y/N/E/W
Reports if there are any geometry checks in the model. If any are found, the
features in question can be highlighted in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
N E N E
Y/N
Reports all geometric tolerances associated with parts, assemblies, and drawings.
Suggested Settings:
Y Y N N
Y/N/E/W
49
ModelCHECK - Help Topic Collection
Reports any holes in the model that do not have standard diameters. If any are
found, you can highlight the features in question in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N/E/W
When ModelCHECK runs on a model that contains ignored features, the ignored
features are listed in the ModelCHECK report and can be highlighted. From the
report, the status of the ignored features can be reset so that ModelCHECK
resumes warnings about the problem.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
If you set a problem to ignore, a window appears in which you must explain the
reason for ignoring the problem. This information is stored in the model as a
feature parameter with the name MC_<CONFIG_TAG>, where CONFIG_TAG is the
name of the check. After this, when ModelCHECK is run, you can browse the
ModelCHECK report to see the ignored problems, along with the names of the
users who ignored them and their comments.
When ModelCHECK uses a configuration file with the IGNORE_FEAT check set to
N, any ignored problems are reported as regular problems.
Suggested Settings:
Y Y Y Y
Y/N/E/W
Reports the number of imported features in the model. If any are found, you can
highlight the features in question in the Pro/ENGINEER window.
50
ModelCHECK
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
Y Y N N
Y/N/E/W
Reports whether any incomplete features exist in the model. If any are found,
you can highlight or delete them in the Pro/ENGINEER window. ModelCHECK
regenerates the model if any incomplete features are deleted.
Suggested Settings:
W E N E
Y/N/E/W
If this is the case, you can deactivate the Insert mode through the ModelCHECK
report.
Suggested Settings:
E E N E
Y/N/E/W
Verifies that the names of family table instances conform to the standard naming
conventions defined by the PRT_INSTANCE_NAME and ASM_INSTANCE_NAME start
configuration options.
This check can also be configured to verify that the names of instances begin
with the same string as the generic.
Suggested Settings:
E E W W
51
ModelCHECK - Help Topic Collection
Y/N/E/W
Checks that no layers are stored in the Isolate (or Display) mode.
Suggested Settings:
W E N E
Y/N/E/W
Checks whether all datum features exist on layers (regardless of their names)
and that the layers are blanked. Datum features that do not exist on layers can
be highlighted.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
W W W W
Y/N/E/W
Lists the layers containing features that do not belong to a given layer. For
example, if a layer is designated as the datum plane layer and it contains
features other than the datum planes, it is listed.
Suggested Settings:
W W W W
Y/N
Lists any layers found in the model and the features that are on each one.
Suggested Settings:
Y Y N N
52
ModelCHECK
Y/N/E/W
Checks that features do not exist on multiple layers. If any are found, the entity
IDs and their feature IDs are listed.
Suggested Settings:
W W W W
• LAYER_MOVE (Move Items from Old Layers to New Ones and Delete the Old One)
Y/N/E/W
Note: Use this check if your standard layer configuration has changed and layers
have to be updated in legacy parts (old models).
Creates a new layer, takes all items from an existing layer, moves them to a new
layer, and then deletes the old layer. To use this check, both the old and new
layers must be named in the start configuration file using the PRT_LAYER_MOVE,
ASM_LAYER_MOVE and DRW_LAYER_MOVE options.
Suggested Settings:
E E E E
Y/N/E/W
Checks whether the standard layers contain the standard features. If any items
are found on wrong layers, you can have ModelCHECK automatically move them
on to correct ones.
o axes
o chamfers
o components
o cosmetic grooves
o cosmetic sketches
o cosmetic threads
o coordinate systems
o curves
o cuts
o datums
53
ModelCHECK - Help Topic Collection
o datum axes
o datum planes
o datum points
o datum quilts
o datum surfaces
o drafts
o draft lines
o groups
o geometric tolerances
o holes
o notes
o protrusions
o rounds
o shells
o slots
o symbols
o threads
The PRT_LAYER and ASM_LAYER start configuration options define standard layers.
Suggested Settings:
W E N E
Y/N/E/W
Checks the display status of the standard named layers. If any layers are not
saved in the right display status, you can have ModelCHECK automatically correct
them. The PRT_LAYER and ASM_LAYER start configuration options define standard
layers.
Suggested Settings:
W E N E
54
ModelCHECK
Y/N/E/W
Suggested Settings:
Y Y N N
Y/N/E/W
Reports the dimensions in the model in which the tolerance is lower than the
standard minimum value. If any are found, you can highlight the features in
question in the Pro/ENGINEER window.
Suggested Settings:
E E E E
Y/N/E/W
Reports whether the model’s material has been defined or not. If it has, its name
and properties are reported. This check also verifies that the defined material
comes from an acceptable list. Standard material names are listed in the start
configuration file using the MATERIAL_NAME configuration option.
Suggested Settings:
W W N W
Y/N
Displays the memory space used while the model is in session. This check is
available only in Batch mode.
Suggested Settings:
55
ModelCHECK - Help Topic Collection
N Y N N
Y/N/E/W
Lists the features that have been merged or cut out in Assembly mode. If any are
found, you can highlight them in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E E E
Y/N
Reports the minimum and maximum linear tolerance used in the model. You can
highlight the minimum and maximum tolerances in the Pro/ENGINEER window.
Suggested Settings:
Y Y Y Y
Y/N/E/W
Verifies that the names of parts and assemblies conform to the standard naming
conventions defined by the PRT_MODEL_NAME and ASM_MODEL_NAME start
configuration options.
Suggested Settings:
E E W W
Y/N
Reports the name of the model. This check primarily creates a parameter that
stores the name of the model. This is done using the ADD_CHK_PARAM start
configuration option.
Suggested Settings:
56
ModelCHECK
Y Y N N
Y/N
Reports the number of features that are named in parts and assemblies and
calculates them as a percentage of all the features in the model. The check also
lists the names of these features.
Suggested Settings:
Y Y N N
Y/N
Reports the length, width, and height of a box that would fit around the model.
Suggested Settings:
Y Y N N
Y/N/E/W
Checks that all standard parameters are present in the model and that they are
of an acceptable type and format.
Suggested Settings:
E E W W
Y/N
Suggested Settings:
57
ModelCHECK - Help Topic Collection
Y Y N N
Checks that required parameter notes are present and marks the unacceptable
parameter notes. Notes can be checked in the following two ways:
o Does a specific parameter exist and does it contain the required text?
o Does a specific parameter exist and does it contain any unacceptable text?
Required parameter notes are designated in the configuration files using the
PRT_PARAM_NOTE_REQ and ASM_PARAM_NOTE_REQ start configuration options.
Unacceptable parameter notes are designated in the configuration files using the
PRT_PARAM_NOTE_UNACC and ASM_PARAM_NOTE_UNACC configuration options.
Suggested Settings:
W W N N
Y/N/E/W
Suggested Settings:
W W W W
Y/N/E/W
Checks that parameter values have been spelled correctly. If any are spelled
incorrectly, you can correct the spelling or add the value to the dictionary.
Suggested Settings:
W W N N
58
ModelCHECK
Y/N/E/W
Reports part parameters that are unused in relations and in family tables. It also
allows deletion of these unused parameters.
Suggested Settings:
W N W N
Y/N/E/W
Reports any datum planes in the model, other than default planes, with no
children. In the start part list in the start configuration file, you can specify a list
of required standard datum planes for a model. The PLANE_CHILD check does
not check these standard datum planes.
If any childless datum planes are found, you can highlight the features in
question in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
E E W E
Y/N/E/W
Reports the datum planes in the model that were created through other datum
planes. If any are found, you can highlight the features in question in the
Pro/ENGINEER window. ModelCHECK cannot highlight features on blanked layers.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
This check also reports datum planes with only one parent, where the datum is
built through the parent. The PLANE_PARENT check does not check any standard
datum planes in the start configuration file.
Suggested Settings:
E E W E
59
ModelCHECK - Help Topic Collection
Y/N/E/W
Reports the version of Pro/ENGINEER that the model was last saved in. The
following start configuration options are available:
o PRT_PRO_VERSION
o ASM_PRO_VERSION
o DRW_PRO_VERSION
Suggested Settings:
W W W W
Y/N/E/W
Checks to see if any RuleCHECK rules have been attached to the model. If so, it
reports any rules in a pending or override state.
Suggested Settings:
E E N N
Y/N
Reports the number of features in the model that are resumed (not suppressed).
Suggested Settings:
Y Y N N
Reports any regeneration problems when a model is fully regenerated. These are
typically problems that are reported in the Pro/ENGINEER message window when
a model is regenerated.
The mc_regen.mcr configuration file is used to specify the messages to search for
and to determine whether a message is an error or a warning message.
Because this check can take considerable time, you run it with the MC Regen
command or in Batch mode.
60
ModelCHECK
Suggested Settings:
E E N N
Y/N/E/W
Checks that every relation has at least one comment line. The comment must
precede the relation.
Note: This check considers all relations within the IF-ENDIF or SOLVE-FOR
statements as one relation.
Suggested Settings:
W W N W
Y/N/E/W
Checks for errors in the model’s relations and reports the relation lines containing
errors.
Suggested Settings:
E E E E
Y/N/E/W
Reports all the assembly or part relations and their respective comments.
Suggested Settings:
Y Y N N
Y/N/E/W
Checks for standard relations and their comments in parts and assemblies. If any
are missing, ModelCHECK adds them to the model.
61
ModelCHECK - Help Topic Collection
Standard relations and comments are listed in the configuration files using the
PRT_COMMENT, PRT_RELATION, ASM_COMMENT and ASM_RELATION start configuration
options.
Suggested Settings:
W W N N
Y/N/E/W
Checks that no dimensions and parameters have been assigned multiple times in
the relations file.
Suggested Settings:
E E N N
Y/N
Lists the names of the part dimension symbols that have been renamed.
Suggested Settings:
Y N Y N
Y/N
Always reports missing layers if set to Y. If set to N, missing layers will only be
reported if a standard feature type for that layer exists in the model.
Suggested Settings:
Y Y Y Y
Y/N/E/W
Lists the features that are children of rounds. If any are found, they can be
highlighted in the Pro/ENGINEER window.
62
ModelCHECK
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
This check ignores children of other rounds, because this is not considered poor
modeling.
Suggested Settings:
E E E E
Y/N/E/W
Runs RuleCHECK when ModelCHECK runs and provides a link to the RuleCHECK
report.
Suggested Settings:
Y Y N N
Y/N/E/W
Lists the sharp edges in the model. Sharp edges are defined by a specified angle
between the two surfaces that intersect at the edge. The angle is set using the
SHARP_ANGLE constant configuration option. If any are found, the features in
question can be highlighted in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
This check takes a relatively long time. If you are concerned about speed, turn it
off.
Suggested Settings:
E E N N
Y/N/E/W
Lists the edges in the model with a length smaller than a specified limit. You can
define the limit for the length using the SHORT_EDGE constant configuration
option. If any short edges are found, the features in question can be highlighted
in the Pro/ENGINEER window.
63
ModelCHECK - Help Topic Collection
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
The value for SHORT_EDGE can be set to CALCULATE. If this is the case, the
value used to determine a short edge is based on the size of the model.
Suggested Settings:
E E E E
Y/N/E/W
Checks that the bend table used for a sheet metal part comes from a standard
list. Standard bend tables are defined using the SHTMTL_BTNAME configuration
option in the start configuration file.
Suggested Settings:
W W W W
Y/N/E/W
Checks for the existence of flat patterns or flat states in sheet metal parts.
A flat state is a completely unbent copy of your part. It streamlines the creation
of flat patterns needed in manufacturing. You can create any number of flat
states, at any time in your design process, whether your part is fully formed or
fully flat. Flat states are managed with family tables.
A flat pattern is a feature that shows the model in its flat state. It is always
positioned as the last feature. When new features are added, the flat pattern
automatically moves to the end of the feature list. Flat patterns allow you to start
working on drawings before the sheet metal part is finished.
Suggested Settings:
W W Y W
Y/N/E/W
Reports whether sheet metal parts have been modeled using standard wall
thickness. If any are found, you can highlight the features in question in the
Pro/ENGINEER window.
64
ModelCHECK
Suggested Settings:
E E E E
Y/N/E/W
Checks for consecutive unbend and bend-back (or vice versa) features in sheet
metal parts. If any are found, delete these redundant features.
Suggested Settings:
W W W W
Y/N
Reports the sheet metal Y-Factor used for sheet metal parts.
Suggested Settings:
Y Y N N
Y/N
Reports whether any simplified representations associated with the model exist.
Suggested Settings:
Y Y Y Y
Y/N/E/W
Checks that the name of simplified representations follows the standard naming
convention defined by the PRT_SIMPREP_NAME and ASM_SIMPREP_NAME start
configuration options.
Suggested Settings:
65
ModelCHECK - Help Topic Collection
E E W W
Y/N/E/W
If the number of entities in a feature exceeds the maximum value, the feature is
reported and you can highlight it in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
N N N N
Y/N/E/W
Reports whether it is possible to generate an SLA output file of the model. This
check takes a relatively long time. If you are concerned about speed, turn it off.
Suggested Settings:
W W N W
Y/N/E/W
Lists the features that have cylindrical surfaces (such as rounds and holes) and
small radii. You can define the minimum radius with the SMALL_RADIUS constant
configuration option. If any are found, the features in question can be highlighted
in the Pro/ENGINEER window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
Suggested Settings:
66
ModelCHECK
E E E E
Y/N/E/W
Lists the edges with either gaps or overlaps between the surfaces that meet. If
any are found, you can highlight the features in question in the Pro/ENGINEER
window.
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported features.
This check takes a relatively long time. If you are concerned about speed, turn it
off.
Suggested Settings:
E E N N
Y/N/E/W
Verifies that the items in the start part and start assembly lists are in the model
and have been created in the standard order (That is, default datum planes
should be features 1, 2, and 3.) Start-part features can be datum planes,
coordinate systems, curves, points, views, parameters, or layers.
Start-part items are defined in the start configuration file with the following
configuration options: PRT_DATUM_PLANE, PRT_DATUM_CSYS, PRT_DATUM_POINT,
PRT_DATUM_CURVE, PRT_DATUM_POINT, PRT_VIEW, PRT_PARAMETER and PRT_LAYER.
Tolerance types are checked as part of the start part. These are specified using
the PRT_TOL_TYPE and ASM_TOL_TYPE start configuration options. The allowable
types of tolerances are DIN/ISO or ANSI.
Suggested Settings:
E E W W
• STD_NOTES_MISSING
Y/N/E/W
Verifies that all standard model notes exist in the model and reports the number
of missing notes. You can define the standard notes in the start configuration file
using the PRT_STD_NOTE and ASM_STD_NOTE start configuration options.
67
ModelCHECK - Help Topic Collection
Suggested Settings:
Y Y Y Y
Y/N/E/W
Lists the types and IDs of the suppressed features in the model. Any features
that are included in family tables or sheet metal flat-pattern features are ignored.
Suggested Settings:
W W N W
Y/N
Lists the UDFs found in the model and the groups to which they belong.
Suggested Settings:
Y Y N N
Y/N/E/W
Checks that the length units are from a standard list of acceptable units.
Standard length unit types are designated in the start configuration file using the
PRT_UNITS_LENGTH and ASM_UNITS_LENGTH configuration options.
Suggested Settings:
W W W W
Y/N/E/W
Checks that the mass units are from a standard list of acceptable units. Standard
mass unit types are designated in the start configuration file using the
PRT_UNITS_MASS and ASM_UNITS_MASS configuration options.
Mass types are case sensitive. Units must be properly defined using the following
key words:
68
ModelCHECK
o KILOGRAM
o POUND
Suggested Settings:
W W Y W
Y/N
Suggested Settings:
Y Y N N
Y/N
Suggested Settings:
Y Y N N
Y/N
Displays the bill of materials of the assembly. You must set this check to Y for an
all-level check on an assembly.
Suggested Settings:
Y Y N N
69
ModelCHECK - Help Topic Collection
Y/N
Reports any assembly features, other than datums, in the model. If any are
found, you can highlight the features in question in the Pro/ENGINEER window.
Suggested Settings:
Y Y Y Y
Y/N/E/W
Suggested Settings:
Y Y N Y
Y/N/E/W
Checks for any circular references in the assembly. Circular references occur
when an assembly contains a number of cross references that form a loop.
ModelCHECK reports all the circular references. You can highlight the features or
components involved.
Suggested Settings:
Y Y Y N
Y/N/E/W
Lists all the external dependencies of a model. The names of the assemblies in
which the external dependencies exist are also listed. You can highlight the
external dependencies.
Note: If the referenced models are not in the current session, a corresponding
message appears.
Suggested Settings:
Y N Y N
70
ModelCHECK
Y/N/E/W
Suggested Settings:
E E E E
Y/N/E/W
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported components.
Suggested Settings:
W W W W
Y/N/E/W
Checks the number of days since the last global interference check was run and
whether it was within the acceptable period or not.
The GLOBAL_INTF_DAYS configuration option in the start configuration file sets the
maximum number of days between interference checks. ModelCHECK reports
whether an interference check was done recently or not.
Suggested Settings:
E E E E
Y/N/E/W
Reports missing components. These occur when Pro/ENGINEER does not know
where a component, needed for an assembly, can be found on the disk.
71
ModelCHECK - Help Topic Collection
Suggested Settings:
E E E E
Y/N
Suggested Settings:
Y Y N N
Y/N/E/W
Reports any components that are not fully constrained or that are packaged.
Suggested Settings:
E E W W
Y/N/E/W
You can also access the Global Reference Viewer from the ModelCHECK report to
view all references to and from the reported components.
Suggested Settings:
W W N W
Y/N
Suggested Settings:
72
ModelCHECK
Y Y N N
Y/N/E/W
Checks that no views, entities, dimensions, symbols, notes, and tables lie outside
the boundary of a drawing. If any are found, you can highlight the reported views
or details in the Pro/ENGINEER window.
Note: This check considers the boundary of the drawing and not the boundary of
the format. If an item lies outside the boundary of the format but within the
boundary of the drawing, ModelCHECK does not report it as a problem. If a
drawing has no valid views, ModelCHECK does not check for views, entities,
dimensions, symbols, notes, and tables lying outside the boundary of the
drawing.
Suggested Settings:
W W W W
Y/N/E/W
Reports any views with the hidden line display mode set to the default (and not
the other options, namely, Wireframe, Hidden Line, and No Hidden) in a
drawing.
If any views are found, you can be highlight them from the report.
Suggested Settings:
W W N W
Y/N/E/W
Reports any dimensions modified using @O, which breaks their associations with
the model, allowing you to enter whatever value you choose.
73
ModelCHECK - Help Topic Collection
If any overwritten dimensions are found, you can highlight the features in
question in the Pro/ENGINEER window.
Suggested Settings:
E E E E
Y/N/E/W
Reports any draft geometry in the model that is not associated with a view.
Suggested Settings:
W W W W
Y/N/E/W
Adds all layer functionality from Part and Assembly modes to Drawing mode.
Suggested Settings:
E E W W
Y/N/E/W
Verifies that the name of the drawing conforms to the standard naming
conventions defined by the DRW_MODEL_NAME start configuration option.
Suggested Settings:
E E W W
Y/N/E/W
74
ModelCHECK
Suggested Settings:
E E W W
Y/N/E/W
Checks for erased views in the drawing. Erased views exist in the drawing until
they are deleted.
If any erased views are found, you can highlight, delete, or resume them from
the ModelCHECK report.
Suggested Settings:
E E E E
Y/N/E/W
Checks that the drawing format is from the standard list of acceptable formats.
Standard formats are defined by the DRW_FORMAT start configuration option. If the
drawing does not have a format, ModelCHECK prompts you to add one.
Suggested Settings:
W W N W
Y/N/E/W
Suggested Settings:
75
ModelCHECK - Help Topic Collection
W W N W
Y/N
Suggested Settings:
Y Y N N
Y/N/E/W
Reports notes in lowercase in a model. You can highlight the notes and change
them to uppercase.
Suggested Settings:
W W N W
Y/N/E/W
Reports any drawing notes using a font that is not from the list of approved fonts.
Approved fonts are specified in the start configuration file using the
DRW_NOTE_FONT configuration option.
Suggested Settings:
E E W W
Y/N/E/W
Reports any drawing notes with text that is not from the list of approved sizes.
Approved sizes are specified in the start configuration file using the
DRW_NOTE_HEIGHT configuration option.
Suggested Settings:
E E W W
76
ModelCHECK
Y/N
Lists notes in the drawing with the sheets they are on.
Suggested Settings:
Y Y N N
Y/N/E/W
Checks the drawing for spelling mistakes. If any mistakes are found you can
highlight them or highlight and correct them. Also, you can add the word to the
dictionary so that ModelCHECK accepts it as correct.
Suggested Settings:
E E W E
Y/N/E/W
Suggested Settings:
E E W W
Y/N/E/W
Counts the number of sheets in a drawing and verifies that the number does not
exceed the maximum.
Suggested Settings:
E E N E
77
ModelCHECK - Help Topic Collection
Y/N/E/W
Checks for overlapping views in the drawing. If any are found, the features in
question can be highlighted in the Pro/ENGINEER window.
Suggested Settings:
W W W W
Y/N/E/W
Suggested Settings:
E E E E
Y/N/E/W
Checks the drawing for the standard set of parameters that are driven from
model parameters. Standard parameters are set using the DRW_PARAMETER
configuration option in the start configuration file.
Suggested Settings:
E E E E
Y/N/E/W
Reports any dimensions in the drawing that cannot be regenerated. This problem
occurs if a dimension loses one of the entities it references. The entity may have
been redefined or deleted. (only applies to the MC Regen option)
Suggested Settings:
E E E E
Y/N/E/W
78
ModelCHECK
Lists the number of sheets in the drawing and their respective sizes.
Suggested Settings:
Y Y N N
Y/N/E/W
Compares the current detail settings to a standard drawing detail file on disk. If
any differences are found, ModelCHECK can reset the detail settings to the values
listed in the standard drawing detail file.
Different standard drawing detail files can be specified for different formats using
the STD_DRW_DTL_FILE start configuration option.
Suggested Settings:
E E W W
Y/N
Suggested Settings:
Y Y N N
Y/N/E/W
Checks drawing symbols for spelling mistakes. If any are found, you can highlight
them or highlight and correct them. Also, you can add the word to the dictionary
so that ModelCHECK accepts it as correct.
Suggested Settings:
E E W E
Y/N/E/W
79
ModelCHECK - Help Topic Collection
Verifies that specific table cells contain standard text. Standard table cell text is
designated using the DRW_TABLE_CELLS configuration option in the start
configuration file.
Suggested Settings:
E E W W
Y/N/E/W
Reports any entries in the title block that are not driven by model parameters.
Suggested Settings:
W W W W
Y/N/E/W
Checks the title block for spelling mistakes. If any mistakes are found, you can
highlight them or highlight and correct them. Also, you can add the word to the
dictionary so that ModelCHECK accepts it as correct.
Note: The TITLE_SPELL check works only if the NOTE_SPELL check is active.
Suggested Settings:
E E N E
Y/N/E/W
Checks for any models added to the drawing that have not been used in a view.
If any are found, you can delete them from the drawing.
Suggested Settings:
E E N E
Y/N/E/W
80
ModelCHECK
Checks for empty sheets in the drawing. If any are found, you can delete them
from the drawing.
Suggested Settings:
E E N E
Y/N/E/W
Checks for views in a drawing that have a scale assigned to them and reports the
views that do not. The reported views can be highlighted.
Suggested Settings
W W N W
GeomIntegrityCHECK Checks
You can run GeomIntegrityCHECK in all ModelCHECK operating modes using the
MC_VDA_RUN configuration option in the config_init.mc file. Applicable
GeomIntegrityCHECK checks in Part, Assembly, or Drawing modes follow. The check
name, definition, values to which it can be set, and suggested settings are explained
for each GeomIntegrityCHECK check in the check configuration file. See the
GeomIntegrityCHECK topics for details about the GeomIntegrityCHECK checks.
• M1_TINY_ELMNT (Tiny Elements)
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
81
ModelCHECK - Help Topic Collection
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
• M5_WAVINESS (Waviness)
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
82
ModelCHECK
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
83
ModelCHECK - Help Topic Collection
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
84
ModelCHECK
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
85
ModelCHECK - Help Topic Collection
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
• SO25_CAVITIES (Cavities)
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
Y/N/E/W
Suggested Settings:
E E N N
86
ModelCHECK
3. Select the required start file. A table listing the start file configuration options and
their values appears in the right pane of the PTC ModelCHECK Configuration
Tool dialog box.
Note: Click Create new file to create a new start configuration file. ModelCHECK
dynamically updates all boxes listing start configuration files in the PTC
ModelCHECK Configuration Tool dialog box with the name of the new file.
4. In the Choose items to view box, select the category. All configuration options
of the selected category are listed in the table. The list of categories also includes
the external files used.
5. Select an option to see and edit its definition in the lower table.
6. Edit the configuration options and their definitions using the boxes. Succeeding
items in the definition automatically change according to the current setting.
o To add a configuration option, click Add row, add the definition, and click
Add item.
7. Click Save or Save as to save your changes to the current or a different file,
respectively.
87
ModelCHECK - Help Topic Collection
You can have several start configuration files and use more than one at a time.
88
ModelCHECK
Comment
Drawing Mode
Format DRW_FORMAT
Layer DRW_LAYER
Symbol DRW_SYMBOL
External Files
89
ModelCHECK - Help Topic Collection
Part and Assembly Mode Configuration Options for the Start File
Configuration options available in the start configuration file for Part and Assembly
mode follow.
Model Parameters
Parameters to be added to a model can be specified. Use the following format in the
start configuration file to list the parameters to add to the model:
[MODE]_ADD_CHK_PARAM [parameter] [check_output]
where
• [MODE] is PRT, ASM, or DRW.
For example,
PRT_ADD_CHK_PARAM MATERIAL MATERIAL_INFO
PRT_ADD_CHK_PARAM UNITS_LENGTH UNITS_LENGTH
PRT_ADD_CHK_PARAM MODEL_NAME MODEL_NAME_STR
where
• [MODE] is PRT or ASM.
90
ModelCHECK
• [item_name] is the name of the item. If the name of the item is not important,
use the word NONE.
• [#] is the feature number. If only the feature name is important, you can omit
the feature number.
For example,
PRT_DATUM_AXIS A_1
PRT_DATUM_PLANE DTM1 1
PRT_DATUM_PLANE DTM2 2
PRT_DATUM_PLANE DTM3 3
PRT_DATUM_CSYS NONE 4
ASM_DATUM_POINT PNT_1
ASM_DATUM_CURVE CURVE_1
ASM_DATUM_PLANE ADTM1 1
where
• [MODE] is PRT or ASM.
• [file_name] is the name of the text file for the required notes.
You can define a single note in the start configuration file as follows:
[MODE]_PARAM_NOTE_REQ [parameter] "[NOTE_TEXT]"
Unacceptable parameter notes are defined in the start configuration file or in
separate text files using the following format:
[MODE]_PARAM_NOTE_UNACC [parameter] [file_name].txt
where
• [MODE] is PRT or ASM.
• [file_name] is the name of the text file for the unacceptable notes.
You can define a single note in the start configuration file as follows:
[MODE]_PARAM_NOTE_UNACC [parameter] "[NOTE_TEXT]"
For example:
PRT_PARAM_NOTE_REQ COMPANY notes.txt
ASM_PARAM_NOTE_UNACC DATE "Hello"
91
ModelCHECK - Help Topic Collection
[MODE]_STD_NOTE [NOTE_TEXT]
where
• [MODE] is PRT or ASM.
You can define any number of single-line standard notes using separate lines for
each note. To define notes with multiple lines, use a separate text file as follows:
[MODE]_STD_NOTE FILE:[file_name].txt
where
• [MODE] is PRT or ASM.
• [parameter] is the name of the parameter that should exist in all family tables.
For example:
PRT_FT_PARAMETER PN
ASM_FT_PARAMETER MODELNAME
Layer Move
For legacy parts, ModelCHECK can create new layers, move items from old layers to
the new ones, and delete the old layers. Use the following format in the start
configuration file to set up a change in layers:
[MODE]_LAYER_MOVE [old_layer] [new_layer]
where
• [MODE] is PRT or ASM.
For example:
PRT_LAYER_MOVE DTMS DATUMS
PRT_LAYER_MOVE CSYS DATUMS
92
ModelCHECK
A layer called DATUMS will be created in the model, all features from the DTMS and
CSYS layers will be moved to the DATUMS layer, and the DTMS and CSYS layers will be
deleted.
Layers
ModelCHECK can do the following:
• Check the display status of layers.
• Find standard layers and check their status settings. If the status of a layer is not
set correctly, ModelCHECK can change it at your request.
• Find certain features on specific layers. If a standard layer does not have all
expected features, ModelCHECK can incorporate them as requested.
Use the following format in the start configuration file to configure layers:
[MODE]_LAYER [layer] [layer_status] [entity_type]
where
• [MODE] is PRT or ASM or DRW.
o BLANK—Layer is unavailable.
o DISPLAY—Layer is displayed.
• [entity_type] is the entity type. Leave blank if there are no standard items for
the layer in question. The acceptable values are listed in the next table.
SYMBOLS THREAD
93
ModelCHECK - Help Topic Collection
(DRW)
For example:
Feature names can be listed as entity types using a named list as LIST_XXX
where XXX is the name of the list used. For example, to specify that default
datums must go on a layer called DEFAULT_DATUMS, use the following syntax:
Then create a list of datum names to include on this layer (create this list either
in the start configuration file or in an external file referenced by the start
configuration file):
LIST_DEF DTM1
LIST_DEF DTM2
LIST_DEF DTM3
LIST_DEF CSYS_0
If EXCLUSIVE is added to the end of the line, ModelCHECK ignores the listed features
in the rules set for other layers.
Lines that use the EXCLUSIVE option should be placed before lines that are not
exclusive in the configuration files.
Extra Layers
Layers in the model that are not listed as start items can be reported as extra layers.
ModelCHECK lists extra layers that you can delete from the model. This check is
configured in the check configuration file as follows:
EXTRA_LAYERS YNEW W W N N Y
Sub-Layers
Layers can be specified to have a standard list of sub-layers (other layers) on them.
To set this up, use the following line:
PRT_LAYER LAYER_NAME BLANK LIST_LAYERS
94
ModelCHECK
Length Units
The length units of the model can be checked and verified as being from an
acceptable list. These units are configured in the start configuration file as shown in
the following example:
PRT_UNITS_LENGTH INCH
PRT_UNITS_LENGTH MM
Mass Units
The mass units of the model can be checked and verified as being from an
acceptable list. These are configured in the start configuration file as shown in the
following example:
PRT_UNITS_MASS KILOGRAM
ASM_UNITS_MASS POUND
Material Name
The material name can be checked and verified as being from an acceptable list. This
option is configured in the start configuration file as shown in the following example:
MATERIAL_NAME STEEL
MATERIAL_NAME ALUMINUM
You can update the material from the ModelCHECK report. To do this, a valid
material file having the .mat extension must exist in either the working directory or
in the location specified by the pro_material_dir configuration option in the
config.pro file.
Model Name
ModelCHECK can verify that Pro/ENGINEER model names, instances, and simplified
representations conform to company-specific naming standards in the following
ways:
• Are file names less than, equal to, or greater than a specific number of
characters?
Use the following format in the start configuration file to configure layers:
[MODE]_[MOD_INST]_NAME [equality] [value]
where
• [MODE] is PRT or ASM.
95
ModelCHECK - Help Topic Collection
o EQ—Equal to
o NEQ—Not equal to
• [value] is the value of the model name. Rules for values are:
o Use ALL_CHARACTERS to verify that all models have names that consist only
of characters. This check ignores dashes (-) or underscores (_) found in
names.
o Use ALL_NUMBERS to verify that all models have names that consist of only
numbers. This check ignores dashes (-) or underscores (_) found in names.
o Use LENGTH_## where ## is a number. This check verifies that the number
of characters in model names is either less than, less than or equal to,
equal to, greater than, or greater than or equal to a specific number.
PRT_MODEL_NAME EQ LIST_NAMES
LIST_NAMES CE_*
LIST_NAMES CD_*
LIST_NAMES EO_*
This check would verify that all model names begin with CE_, CD_ or EO_.
Alternatively, you can refer to a text file that contains the list, as follows:
LIST_NAMES text/list.txt
96
ModelCHECK
For example:
PRT_MODEL_NAME EQ ALL_CHARACTERS
PRT_MODEL_NAME EQ ALL_NUMBERS
PRT_MODEL_NAME EQ LIST_NAMES
PRT_INSTANCE_NAME EQ XYZ_*
PRT_INSTANCE_NAME EQ GENERIC
ASM_MODEL_NAME LT LENGTH_12
ASM_INSTANCE_NAME EQ E_##_*
DRW_MODEL_NAME EQ CD_*
DRW_MODEL_NAME EQ ???_CD
DRW_MODEL_NAME EQ FIRST_MODEL
Examples of wildcards:
• *test—The value has to end in test, so model test would be an acceptable value.
• ??-??—The value has to be five characters long with a hyphen (–) as the third
character.
Parameter Rename
ModelCHECK can rename parameters from old names to new ones while preserving
their values. Use the following format in the start configuration file to rename
parameters:
[MODE]_PARAM_RENAME [old_name] [new_name]
where
• [MODE] is PRT or ASM.
For example:
PRT_PARAM_RENAME GAVIN FINN
ASM_PARAM_RENAME WAYNE HOLDEN
Given the above configuration options, when you run ModelCHECK on a part or an
assembly, if it finds a parameter called GAVIN, it allows you to rename it to FINN.
Parameters
ModelCHECK includes a parameter check that verifies that the model parameters
conform to your company standards. The following information can be verified in
parameters:
97
ModelCHECK - Help Topic Collection
• Are numerical parameters less than, greater than, or equal to a specific value?
Use the following format in the start configuration file to rename parameters:
[MODE]_PARAMETER [name] [type] [equality] [value]
where
• [MODE] is PRT or ASM.
• [type] is the type of the parameter. The following values are acceptable:
o STR—String value
o INTEGER—Integer value
o REAL—Real value
o LT—Less than
o GT—Greater than
• [value] is the value. The value is case-sensitive. The following values are
applicable:
o The exact value can be specified, or a number can be given for less-than or
greater-than checks.
o NULL can be specified if the parameter does not have an assigned value.
98
ModelCHECK
Specify each member of the list on a separate line in the start configuration
file:
This list would allow the three names as acceptable values for the given
parameter.
For example:
PRT_PARAMETER MODEL STR EQ circ
PRT_PARAMETER PN NONE EQ PDM
PRT_PARAMETER PN NONE EQ ????-???
PRT_PARAMETER COMPANY STR EQ PTC
PRT_PARAMETER EMPTY NONE EQ NULL
PRT_PARAMETER DRAWN_BY STR EQ LIST_DESIGNERS
PRT_PARAMETER RELEASED BOOL EQ YES
PRT_PARAMETER DRAFT_ANGLE REAL LTE 5
PRT_PARAMETER DESCRIPTION STR EQ *test
PRT_PARAMETER MATERIAL STR EQ PDM
PRT_PARAMETER RC_MODEL_TYPE STR EQ LIST_MODEL_TYPE
PRT_PARAMETER ENG_PRJ_NO STR EQ PDM
PRT_PARAMETER DEPARTMENT STR LTE LENGTH_12
PRT_PARAMETER MASS REAL
PRT_PARAMETER VOLUME REAL
PRT_PARAMETER MC_INT INTEGER EQ 12345
PRT_PARAMETER MC_REAL REAL EQ 5.33
Wildcard examples:
• *test—The value has to end in test, so model test would be an acceptable value.
• ??-??—The value has to be five characters long with a hyphen (-) as the third
character.
99
ModelCHECK - Help Topic Collection
Note: Parameters in the model that are not listed as start items can be reported as
extra parameters by setting the EXTRA_PARAMS check in the check configuration
file. ModelCHECK lists extra parameters and you can delete them from the model.
Tolerance Type
ModelCHECK can verify the type of tolerance used for the model. Two types are
available, ANSI and DIN/ISO. Use the following format in the start configuration file:
PRT_TOL_TYPE ANSI
PRT_TOL_TYPE DIN/ISO
Views
Standard views are listed in the start configuration file as shown in the following
example:
PRT_VIEW FRONT
ASM_VIEW SIDE
100
ModelCHECK
Drawing Format
Standard drawing formats are listed in the start configuration file as shown in the
following example:
DRW_FORMAT A_MFG
DRW_FORMAT A_QC
Any formats listed here must be files having the .frm extension and located in a
directory where Pro/ENGINEER can find them. This means that they either have to
exist in the Pro/ENGINEER formats directory or in a location specified by the
PRO_FORMAT_DIR configuration option in your config.pro file.
Drawing Layers
Standard drawing layers are listed using the DRW_LAYER configuration option exactly
as in the part and assembly modes.
Drawing Symbols
Standard drawing symbols are listed in the start configuration file as shown in the
following example:
DRW_SYMBOL PTC_LOGO
DRW_SYMBOL ANSI
Format
This is set up using the following syntax:
DRW_TABLE_CELLS [row1, col1, str1] [row2, col2, str2]
101
ModelCHECK - Help Topic Collection
For example:
DRW_TABLE_CELLS [1,1,BOM] [4,2,PTC]
Then, a certain cell can be checked in every table for specific text.
This is set up as follows:
DRW_TABLE_CELLS [row,col,string]
Where
• [PARAM_NAME] is the name of a parameter that must exist in the drawing in order
to complete this check. If the parameter does not exist, this check is skipped.
o LIST_xxx—A list of sheets. You can create a list using the following syntax:
LIST_xxx 1
LIST_xxx 2
102
ModelCHECK
can specify the external files that ModelCHECK must use in the start configuration
file.
1. Click adjacent to Text Files in the left pane of the PTC ModelCHECK
Configuration Tool dialog box.
2. Select the required text file. A table listing the contents of the file appears in the
right pane of the PTC ModelCHECK Configuration Tool dialog box.
3. Edit the contents using the boxes. You can add and delete rows as required.
4. Click Save or Save as to save your changes to the current or a different file,
respectively.
The hole and cut diameter file has the following format:
# ModelCHECK Standard Hole Size File
#
UNIT INCH
.125
.25
.375
UNIT MM
2.5
3
4
4.1
Note: The declaration of units must be in uppercase.
103
ModelCHECK - Help Topic Collection
Custom Checks
Specifies the name of the external text file in which custom checks are listed in the
start configuration file. For example:
CUSTOM_CHECKS_FILE c:\apps\mc\config\text\custom_checks.txt
External Lists
Most list items can be moved to external text files. This helps to keep the
configuration files short so you can reuse list items in multiple configuration files.
The following items can be placed in external lists:
• Lists of Parameter Values
104
ModelCHECK
• Standard Relations
• Unit Lengths
• Unit Mass
• Drawing Symbols
The two text files would then contain the following lines:
• designers.txt
• model_names.txt
LIST_MODEL_NAMES block
LIST_MODEL_NAMES bolt
105
ModelCHECK - Help Topic Collection
The settings in the current drawing detail file, also known as the drawing setup file,
are compared to the settings in a standard drawing detail file that is saved on disk.
Different standard drawing detail files can be specified for different format names
using the STD_DRW_DTL_FILE start configuration option as follows:
STD_DRW_DTL_FILE [format_name] [path to the drawing detail file]
A line-by-line comparison between the specified drawing detail file and the one that
is currently set for the drawing is performed and any discrepancies are reported in
the ModelCHECK report.
There is no limit to the number of standard drawing detail files that you can specify.
It is suggested that you set the following line at the end of all standard drawing
detail file listings in the start configuration file:
STD_DRW_DTL_FILE DEFAULT [file_name]
The standard drawing detail file specified in the DEFAULT line is used if the format
for the drawing being checked is not listed in the lines before it in the start
configuration file.
Drawing Information
You can specify the location of an external text file for drawing formats using the
STD_DRW_INFO_FILE start configuration option.
The external text file may contain the following drawing items:
106
ModelCHECK
Regeneration Messages
When a model is regenerated from its first feature, warning messages are sometimes
displayed in the Pro/ENGINEER message window. ModelCHECK can report the
messages as either errors or warnings. The checks to enable this are REGEN_ERRS
and REGEN_WRNS.
The text that is searched for is configured in a file that has a default name of
mc_regen.mcr, which is found in the ModelCHECK config directory.
The MC_REGEN_CONFIG_FILE configuration option in the start configuration file is used
to specify the name and location of the mc_regen.mcr file as shown below:
MC_REGEN_CONFIG_FILE text\mc_regen.mcr
There are two sections to the mc_regen.mcr file, one for errors and another for
warnings. Each line is designated by either an E or a W. Below is an example of what
this file looks like:
# ModelCHECK Regen Config file (amn) 9-27-99
# This file contains a list of strings to search for
# among the lines that are output when MC Regen is run.
# The format is either E:strings or W:strings
# E means to consider all matching lines to be errors
# W means to consider all matching lines to be warnings
E:ERROR
E:Reference for the section entity no longer exists
E:WARNING: CUT is entirely outside the model
W:WARNING: Design intent is unclear
107
ModelCHECK - Help Topic Collection
The new check is listed in the check configuration file using the following syntax:
[CHK]_[user_defined_name]_[check_mode] YNEW E E E E Y
Where:
• CHK specifies that it is a custom check.
• check_mode is the mode in which the check is to be run. The mode can be PRT,
DRW, or ASM.
The check definition is stored in a separate file and is specified in the start
configuration file as follows:
CUSTOM_CHECKS_FILE custom_check.txt
The file can be named whatever you like. In this instance it is called
custom_check.txt. If no path is given, the file is assumed to be in the config
directory.
# CUSTOM1
CND_CUSTOM1 GT 25
The following operators are allowed: LT, GT, EQ, NEQ, LTE, and GTE.
• CND_(user_defined_name)—Definition of condition
The following operators are allowed: LT, GT, EQ, NEQ, LTE, and GTE.
GT 20 AND LT 30
• MSG_(user_defined_name)—Report message
108
ModelCHECK
3. Select the required constant file. A table listing the constants and their values
appears in the right pane of the PTC ModelCHECK Configuration Tool dialog
box.
Note: Click Create new file to create a new constant configuration file.
ModelCHECK dynamically updates all boxes listing constant configuration files in
the PTC ModelCHECK Configuration Tool dialog box with the name of the new
file.
You can add and delete rows to add and delete constants, respectively.
5. Click Save or Save as to save your changes to the current or a different file,
respectively.
2. Add options to specify constant values. Save the file with the .mcn extension.
SHORT_EDGE CALCULATE
PERC_EARLY_ROUND 0.5
PERC_EARLY_CHAM 0.5
PERC_EARLY_DRAFT 0.5
SMALL_RADIUS 0.5
ACCURACY_LOW 0.0005
ACCURACY_UPP 0.0013
109
ModelCHECK - Help Topic Collection
MIN_ABS_ACCURACY 0.001
MAX_ABS_ACCURACY 0.02
SHARP_ANGLE 10.0
GLOBAL_INTF_DAYS 1
MIN_TOLERANCE 0.1
SHORT_EDGE_BATCH 0.5
RC_PARAMETER_NAME PART_TYPE
PERC_EARLY_COSMETIC 0.7
MAX_SKETCH_ITEMS 100
MCSI1_TOL 0.100000
MCSI2_TOL 0.100000
MCSI3_TOL 0.100000
MCSI4_TOL 0.100000
MCSI5_TOL 0.100000
TINY_ELMNT_TOL 0.0012
TINY_ELMNT_AREA_TOL 0.020
TINY_DRW_ELMNT_TOL 0.020
ID_ELMNT_TOL 0.020
ID_DRW_ELMNT_TOL 0.020
POS_CONT_TOL1 0.100
TANG_CONT_TOL2 0.100
CURV_CONT_TOL3 10.000
POLYN_DEG_TOL 11
KNOT_TOL 0.020
SELF_DIST_TOL 0.020
TINY_SEGMENT_TOL 0.200
CURVATURE_RAD_TOL 0.500
BOUND_ANGLE_MIN 1.000
BOUND_CRV_INT_TOL 0.09
BOUND_CRV_SRF_TOL 0.07
NUM_SEGMENT_TOL 2
KNIFE_EDGE_TOL 2.000
DIST_VERT_EDGE_TOL 0.020
DIST_VERT_FACE_TOL 0.020
Defines the minimum length of edges before ModelCHECK considers them short.
o A numeric value.
110
ModelCHECK
In Batch mode, ModelCHECK does not calculate the suggested value for
short edges. The SHORT_EDGE_BATCH configuration option is used to set the
value in this case.
• PERC_EARLY_ROUND
Defines the percentage of all features in a model, starting from the top of the
Model Tree, in which a round must not be present.
• PERC_EARLY_DRAFT
Defines the percentage of all features in a model, starting from the top of the
Model Tree, in which draft features must not be present.
• PERC_EARLY_CHAMF
Defines the percentage of all features in a model, starting from the top of the
Model Tree, in which chamfers must not be present.
• SMALL_RADIUS
Defines the minimum radius of cylindrical surfaces (for rounds, holes, and so on).
• ACCURACY_LOW
• ACCURACY_UPP
• MIN_ABS_ACCURACY
Defines the minimum acceptable value for a model’s absolute accuracy. This
option is only used if the model’s accuracy is set to absolute.
• MAX_DRAW_SHEETS
• MAX_ABS_ACCURACY
Defines the maximum acceptable value for a model’s absolute accuracy. This is
only used if the model’s accuracy is set to absolute.
• SHARP_ANGLE
Defines the minimum angle between two surfaces that are considered sharp.
• MIN_TOLERANCE
• RC_PARAMETER_NAME
111
ModelCHECK - Help Topic Collection
Determine the set of rules for RuleCHECK to apply to the model. If this line does
not exist in the configuration file, the RC_MODEL_TYPE parameter is used by
default.
• PERC_EARLY_COSMETIC
• MAX_SKETCH_ITEMS
• MCSI1_TOL
• MCSI2_TOL
Defines the tolerance value, as a percentage, for the surface area of a model.
ModelCHECK uses this value to search for duplicate models. The largest allowable
value is 0.1, that is, 10%.
• MCSI3_TOL
Defines the tolerance value, as a percentage, for the first principal moment of
inertia of a model. ModelCHECK uses this value to search for duplicate models.
The largest allowable value is 0.1, that is, 10%.
• MCSI4_TOL
Defines the tolerance value, as a percentage, for the second principal moment of
inertia of a model. ModelCHECK uses this value to search for duplicate models.
The largest allowable value is 0.1, that is, 10%.
• MCSI5_TOL
Defines the tolerance value, as a percentage, for the third principal moment of
inertia of a model. ModelCHECK uses this value to search for duplicate models.
The largest allowable value is 0.1, that is, 10%.
GeomIntegrityCHECK Constants
• TINY_ELMNT_TOL
• TINY_ELMNT_AREA_TOL
• TINY_DRW_ELMNT_TOL
• ID_ELMNT_TOL
• ID_DRW_ELMNT_TOL
• POS_CONT_TOL1
112
ModelCHECK
• TANG_CONT_TOL2
• CURV_CONT_TOL3
• POLYN_DEG_TOL
• KNOT_TOL
• SELF_DIST_TOL
• TINY_SEGMENT_TOL
• CURVATURE_RAD_TOL
• BOUND_ANGLE_MIN
• BOUND_CRV_INT_TOL
• BOUND_CRV_SRF_TOL
• NUM_SEGMENT_TOL
• KNIFE_EDGE_TOL
• DIST_VERT_EDGE_TOL
• DIST_VERT_FACE_TOL
• Yellow—less than or equal to the number of errors or warnings for the YELLOW
option and greater than the numbers for the GREEN option in the status
configuration file.
• Red—greater than the number of errors or warnings for the YELLOW option in the
status configuration file.
113
ModelCHECK - Help Topic Collection
3. Select the required status file. A table listing the status definitions appears in the
right pane of the PTC ModelCHECK Configuration Tool dialog box.
Note: Click Create new file to create a new status configuration file.
ModelCHECK dynamically updates all boxes listing status configuration files in the
PTC ModelCHECK Configuration Tool dialog box with the name of the new file.
4. Edit the status definitions using the boxes for the maximum number of errors and
warnings.
You can add and delete rows to add and delete status definitions, respectively.
5. Click Save or Save as to save your changes to the current or a different file,
respectively.
2. Add the criteria for the status. Save the file with the .mcq extension.
• The status of the model is yellow if there are not more than 8 errors and (or) 15
warnings.
• The status of the model is red if there are more than 8 errors and (or) 15
warnings.
114
ModelCHECK
• Add the word to the dictionary as spelled correctly. The word remains accessible
to all ModelCHECK users.
2. Run ModelCHECK. If spelling errors are found, a link to a report page appears.
ModelCHECK Reports
• msg_mcmisc.txt
• msg_mcdesc.txt
115
ModelCHECK - Help Topic Collection
Note: Preserve the format of any file you edit. Do not change the first two lines
of each entry (the check name or the original message).
2. The tabs in the top bar of the report show the categories under which the checks
are classified. Choose a category to see the results of specific checks.
Note: The All tab is chosen by default displaying the checks configured as errors
or warnings.
3. The bar below the tabs shows the model name and its status. Click the arrow
adjacent to the model name to see information about the model such as the date
of the report, the operating mode, the configuration files used, the user who
checked the model, the user who last saved the model, and the date when the
model was created. Click to generate and display a report that can be
printed.
4. The table in the report gives a list of checks. Click the check boxes above the
table to further refine the display of the checks as follows:
o Click the check box to show the failed checks that have been configured
as errors.
o Click the check box to show the failed checks that have been configured
as warnings.
o Click the check box to show the checks that are successful.
116
ModelCHECK
Note: Only the errors and warnings are shown by default. A number adjacent to
each check box indicates the number of checks of each type.
o A serial number
Note: You can sort the table based on the status, name, and results. By default,
the table is sorted by the name of the check.
5. To access the online help for a check, click , , , or to the left of the
name of each check in the table. A page with information specific to the check
appears.
6. Click the name of a check in the table to see its details and instances in the lower
part of the report.
In the lower part of the report, you can perform actions on the model such as:
o Highlight a feature
o Ignore a problem
o Delete a feature
o Update information
o View references
117
ModelCHECK - Help Topic Collection
The following example shows how the msg_mcmsg.txt file can be modified. The
DISK_SPACE entry has a default value of File Size. It was changed to Disk Space
Used.
!
REPORT MESSAGES
DISK_SPACE
File size:
MEMORY_SPACE
Memory space:
INSTANCE_NAME
Summary Reports
You can configure ModelCHECK to create HTML-based summary reports by setting
the HTML_FILE_OUTPUT configuration option in the config_init.mc file to Y. The
types of summary reports are:
• Summary report for single parts, assemblies, and drawings
118
ModelCHECK
The summary reports and the corresponding XML-based reports are written to the
directory specified by the DIR_REPORT configuration option in the config_init.mc
file.
Optimizing ModelCHECK
You can change the name of the parameter by editing the condition.mcc file as
follows:
#OVERRIDE CHECKS
IF (<parameter_name>) NOCHECK
• The most resource intensive checks follow. By disabling them, you can increase
the speed of ModelCHECK by about 50 percent.
o SHARP_EDGE
o SRF_EDGES
o ACCURACY_INFO
o SLA_INFO
o ADD_CHK_PARAM
119
ModelCHECK - Help Topic Collection
o SKETCH_ITEMS
o DUPLICATE_MODELS
o STD_DTL_SETUP
o NOTE_INFO
RuleCHECK
About RuleCHECK
RuleCHECK, a component of ModelCHECK, allows companies to easily document and
enforce important engineering rules. This tool can be used to develop a design
advisor for Pro/ENGINEER users.
Rules can be defined to describe a company’s engineering rules, design process
steps, required deliverables, and Pro/ENGINEER best practices. Each type of part and
assembly that a company designs can have specific rules assigned for it.
The RuleCHECK report shows the names and description of the rules applied to the
model.
To Start RuleCHECK
1. Open a part or assembly.
Types of Rules
Some types of rules a company can use are:
• Engineering rules
These rules can include required part thickness, clearances, draft angles, or
materials. These rules capture a company's knowledge base on how to design
high quality parts that are easy to manufacture. They can be used to offer design
advice to new engineers.
120
ModelCHECK
• Required deliverables
Pro/ENGINEER contains many advanced features that allow the efficient modeling
of complex products. Unfortunately, many users are not well trained in functions
such as user-defined features (UDFs), simplified representations, interchange,
reroute, and how to properly use master models. Specific functions can be
recommended for use on different types of models.
Defining Rules
RuleCHECK can attach different rules to different types of models. Model types are
defined with the RC_MODEL_TYPE model parameter. This parameter allows you to use
parameters that already exist in your model. RuleCHECK uses the RC_MODEL_TYPE
parameter to determine which set of rules to associate with the model. You must
define this parameter in each model. The existence and proper definition of this
parameter can be checked by ModelCHECK.
Each set of rules is stored in a separate file. By default, the rule files are in
<proengineer-loadpoint>/modchk/text/<language>/rules. These files can have
any name, but must have a .rule extension. In order to associate a model with a
set of rules, the value of the RC_MODEL_TYPE parameter and the rule file name must
be the same. The following table illustrates this:
Steel steel.rule
Sheetmetal sheetmetal.rule
Casting casting.rule
Two types of rules can be defined: soft rules and hard rules.
Soft Rules
Soft rules offer design advice to users. These general guidelines do not need to be
followed specifically.
Hard Rules
121
ModelCHECK - Help Topic Collection
Hard rules offer design advice that must be followed explicitly. RuleCHECK attaches a
status to each of these rules. You must sign off that these rules have been satisfied.
The status of each rule can be set to one of three states:
• Pending—The rule has been attached to the model, but it has not yet been
applied. This is the default status.
• Complete—The rule has been applied to the model. You can also add comments
to the rules. When you set a rule’s status to complete, you have to sign off that
the rule has been satisfied.
• Override—The rule has been overridden. If you cannot satisfy a rule, you must
document that you attempted to conform to the rule, but could not. In order to
continue you must enter the reason for overriding the rule.
Implementing RuleCHECK
RuleCHECK can be used to offer advice and enforce design rules. It can also be used
to document a design process for possible automation.
As a design advisor, RuleCHECK offers immediate access to a company’s design
knowledge. Often this information is stored in design manuals, industry design
codes, and in the minds of senior designers. Engineers must know when and where
to search for this information. Today, products are becoming more complex, design
time is reduced, and there is considerable turnover and reorganization of engineering
staff. Immediate access to correct and up-to-date engineering knowledge is critical
to the success of many projects. With RuleCHECK, this information is made available
in a proactive fashion and is integrated directly into the Pro/ENGINEER design
environment.
When creating a design automation system for Pro/ENGINEER, the most critical step
is to define the equations, rules, and design steps. Once these have been defined, it
still requires considerable effort to capture these in software and then test and debug
the system. Often during testing of the automation system, it is found that several
important rules or conditions were not anticipated. It then requires a lot of time and
effort to add these to the system.
With RuleCHECK, all the equations, rules, and design steps can be defined and
presented to the users without developing any custom software. Designs are
performed interactively in Pro/ENGINEER following these guidelines. As new rules
and conditions are encountered, they can be easily added to RuleCHECK for future
projects. Once most designs can be completed by explicitly following the steps
defined by RuleCHECK, these steps can be captured in a Pro/TOOLKIT application to
perform the design process automatically.
122
ModelCHECK
• Diameter—Soft
• Thickness—Hard
123
ModelCHECK - Help Topic Collection
The corresponding RuleCHECK report shows the names of the soft and hard rules.
Select a name to see the description and the status of the rule if it is a hard rule. You
can edit the status.
Using GeomIntegrityCHECK
About GeomIntegrityCHECK
The GeomIntegrityCHECK utility:
• Ensures that models comply with the Verbund der Automobilindustrie (VDA) 4955
design specifications.
• Validates the geometry in a model and identifies areas that could make it difficult
to import a model into a downstream application or another CAD system.
To Set Up GeomIntegrityCHECK
1. In the left pane of the PTC ModelCHECK Configuration Tool dialog box, click
GeomIntegrityCHECK settings.
Note: The config.gmc file must be available in the directory specified by the
$MCDIR environment variable and must have access permissions. If the file is not
available, the GeomIntegrityCHECK configurations options are not visible.
However you can run GeomIntegrityCHECK. In this case, GeomIntegrityCHECK
uses the config.gmc file in the system directory, in which configuration files are
stored. The path of the file is as follows:
124
ModelCHECK
<modelcheck-loadpoint>/text/<language>/config/config.gmc
2. Under Configuration File, the names of the default configuration directory and
the default configuration file are displayed in their respective boxes.
o Save As—Save in a separate file the changes you made to the default
check values. The file can be retrieved later when checking a particular
shape.
Note: You can give a new configuration file any name, as long as it has the
.gmc extension.
o Reset—Reset check values to those that are in the file that is displayed in
the Config File box.
Note:
o When you change the default check values, the changes remain in effect for
the remainder of that session. The default settings reappear when
Pro/ENGINEER is started again.
Working directory—The directory in which you store the files you created.
3. Under Geom Checks and Allowed Values, set the check values. This
information is described in more detail in the following topics:
o Surface Checks
o Face Checks
o Topology Checks
o Solids Checks
To Start GeomIntegrityCHECK
To start GeomIntegrityCHECK when running ModelCHECK interactively on the current
model:
1. Click Analysis > ModelCHECK. The ModelCHECK menu appears.
125
ModelCHECK - Help Topic Collection
3. In the Model to Check list, click the name of the file containing the model that
you want to check. In Part mode, you can check only the part in the current
session. In Assembly mode, you can either select any component of the assembly
or click Check Sub-Models to check all the components of the assembly.
4. Under Text Report, in the Report Name box, type a name for the
GeomIntegrityCHECK report, or accept the default name, that is, <name of
model>.a.vda.mct for assemblies and <name of model>.p.vda.mct for parts.
o A text-based report
The text report is stored in the specified directory. You do not see this report, but
it can be used as reference.
5. Click OK to start the checking process, or click Cancel to enter new settings.
126
ModelCHECK
All the GeomIntegrityCHECK checks and their configuration options and default
settings are listed in the following table. For details, see the topics for the checks.
In the Default Status column, E stands for error warning. This means that when a
check is set to E, GeomIntegrityCHECK reports as an error any lack of compliance
with the default setting for that check.
127
ModelCHECK - Help Topic Collection
128
ModelCHECK
1 TOL
Recommended solution:
129
ModelCHECK - Help Topic Collection
1 TOL
In addition, faulty tiny elements require larger storage space and increase
the likelihood of continuity problems. These elements often occur as a
result of system automation and the automatic closure of gaps in the when
data is imported from other systems.
1 Patch 1
2 Patch 2
130
ModelCHECK
Recommended solution:
Note: A surface is the base face of a part that can protrude beyond the
contours of the part. Surfaces are generally bounded with simple
mathematical boundary curves and usually serve as a surface for the
bounded surfaces with complex edge curves.
o In bounded surfaces:
Faces that fall short of the value in your configuration file can lead to invalid
elements and thereby to gaps, especially with certain geometrical
operations (for example, scaling formation of offsets), during the exchange
of data (in a system with inferior exactness), or by subsequent processing
(NC).
Recommended solution:
Delete the bounded surface. Enlarge and adapt the neighboring elements
accordingly.
o In solids:
131
ModelCHECK - Help Topic Collection
1 &=TOL
The three main directions of expansion (for example, the main axis of
inertia) in a rectangular solid are examined. If the extension of the solid is
smaller in two coordinate directions than specified in your configuration file,
the element is reported.
The volume of the solid is also checked against the value in the
configuration file. If the volume is smaller than specified, the solid is
reported.
Recommended solution:
Delete the marked tiny elements as long as they are not associatively
connected with other geometry.
o In drawings:
132
ModelCHECK
1 TOL
Recommended solution:
o In surfaces:
1 TOL
o In drawings:
During the generation of a drawing, identical elements (that is, several lines
of varying or equal length over one another) can occur unintentionally,
which unnecessarily enlarges the space requirements of the model.
Identical elements often hinder, for example, the automatic recognition of
continuous curve paths.
Recommended solution:
• Position Continuity
133
ModelCHECK - Help Topic Collection
Note: A curve path consists of one or more curves with several internal
segments. Generally, there are continuity requirements that have to be fulfilled
on the borders of segments and curves. These are position continuity, tangential
continuity, and curvature continuity.
1 TOL
2 TOL
Recommended solution:
Insert a small fill piece, possibly a tiny element, in the gap that makes the
discontinuity too large.
o In surfaces:
134
ModelCHECK
1 TOL
Recommended solution:
o In topologies:
1 TOL
Recommended solution:
In the case of gaps in face transitions, regenerate the affected faces with
common boundary curves.
135
ModelCHECK - Help Topic Collection
• Tangential Continuity
1 W_TOL
Recommended solution:
o In surfaces:
136
ModelCHECK
1 W_TOL
o In topologies:
• Curvature Continuity
137
ModelCHECK - Help Topic Collection
Recommended solution:
Replace the faulty elements with elements that have suitable curvature
conditions at each end. For example, elements with constant curvatures,
such as straight lines and circles, should be replaced with free-form curves.
o In surfaces:
o In topologies:
• Polynomial Degree
138
ModelCHECK
Recommended solution:
Avoid polynomial degrees greater than 9°. Practical experience has shown
that polynomial degrees of up to 6° have proved to be the best.
Unnecessary curves must be subdivided carefully into curves with lower
degrees.
o In surfaces:
139
ModelCHECK - Help Topic Collection
A polynomial degree that is too high can lead to oscillations or, in the case
of a reduction of the degree through approximation, to deterioration of the
data quality with respect to faithfulness of form, storage requirements, and
continuity.
Recommended solution:
Avoid polynomial degrees greater than 9°. Practical experience has shown
that polynomial degrees of up to 6° have proved to be the best.
Unnecessary curves should be subdivided carefully into curves with lower
degrees.
o In drawings:
Recommended solution:
Compare the polynomial degree of curves with the given maximum value
and, if appropriate, approximate through a curve of lesser degree, but with
more segments, considering the specified tolerance.
• Waviness (default check setting: waviness is not allowed in a model; see the
following definition):
o In wire geometry:
140
ModelCHECK
A curve is rated as wavy if the sign changes more than once within a single
segment or more than twice within a triple segment. The change of signs in
the curvature should be taken into account only if the sum of the curvature
on both sides of the change of signs is larger than a variable lower limit.
o In surfaces:
A face with more than three sign changes along the total length of a
parametric line or with more than one sign change within one of its
segments is rated wavy. The frequency of sign changes is taken into
account only if the curvature on both sides of a sign change is larger than a
variable lower limit.
Recommended solution:
• Knot Distance
141
ModelCHECK - Help Topic Collection
A knot vector is required for the definition of NURBS and B-Spline curves.
The vector defines, among other things, the number of curve segments and
the continuity of transitions between the individual curve segments.
The vectors are defined through a series of real numbers. Individual knots
can be positioned on top of one another, known as multiple weighting of
knots or multiple knots.
Recommended solution:
o In surfaces:
As is the case with NURBS and B-Spline curves, a knot vector for every
parameter direction is required for the definition of NURBS and B-Spline
faces. These define the number of face segments in the u and v parameter
directions and the continuity of transitions between themselves. The knot
vector is defined through a series of real numbers.
142
ModelCHECK
After you have determined all the settings for the All Geom Type checks, click OK
to start the checking process, or click Cancel to specify new settings.
Self-penetrating curves:
Recommended solution:
During the generation of text and dimensioning, special characters and mutated
vowels (umlauts), as well as ß can lead to transfer problems. An excessively high
number of text characters (>70 per line) as well as multi-line text can lead to
loss during transfer and are for that reason to be avoided. Alternatively, a special
agreement concerning the problem must be reached.
Recommended solution:
143
ModelCHECK - Help Topic Collection
Replace special characters, umlauts, and ß (for example, ä with ae; ß with ss).
Text with more than 70 characters must be divided into several shorter texts.
Multi-line text must be replaced with several single-line texts.
After you have determined all the settings for the Curve & Drawing checks, click
OK to start the checking process, or click Cancel to specify new settings.
Surface Checks
When you click the Surface tab in the Geometry CHECK dialog box, a tabbed page
appears. This page contains the following checks:
• Tiny Segment Edge (default check setting: > 0.02 mm)—GeomIntegrityCHECK
reports the faces and face patches whose extents are smaller in one parameter
direction than specified in your configuration file.
A face patch with one segment edge below the tolerance can lead to undefined
normals in case of a change in the system or tolerance range.
1 R_TOL
2R
The curvature radius of a face must not fall short of the set value at any position,
as lesions can occur on the face during milling. The minimum curvature radius of
a face also limits the maximum clearance of an offset face.
Recommended solution:
144
ModelCHECK
• Angle Between Edge Curves (default check setting: 2° < A < 178°)—
GeomIntegrityCHECK checks whether the angle between the boundary curves of
naturally bounded surfaces lies within the critical range around 0° or 180° or not.
It measures the angles between the tangents of neighboring boundary curves
and compares them with the specified configuration value.
Recommended solution:
Subdivide the surface or enlarge it and generate the required area as a face. The
cases in which the normals on the edge of the face and in the corners are
defined, despite a critical angle, can be ignored if the recipient of the data is in
agreement.
It generates four corner normals in the face segment, a normal at each of the
parametric center points of the four edges and in the center of the face. Then it
makes comparisons within each group.
Generally, all points on a normal vector are shown facing uniformly either toward
or away from a component. Occasionally, deviations occur on the edges of
surfaces. As a result, damage to the work piece can occur, because a tool can cut
into the face.
145
ModelCHECK - Help Topic Collection
The largest corner difference must not exceed the specified value. The specified
value may be changed to 120° in order not to mark the faces with constant
changes in the normals.
Recommended solution:
Recreate the faces on which the vectors for normals have been turned around.
When doing so, carefully consider the tangential conditions at the periphery.
Recommended solution:
Demarcate the surfaces with large curvature differences. A surface with harmonic
curvature distribution and a large number of smaller segments can be replaced
with a surface of a higher degree.
146
ModelCHECK
1 Patch 2
2 Face
3 Patch 1
The area of a face that is occupied by a bounded face can, in individual cases, be
so small that whole rows of patches are unoccupied. These rows unnecessarily
take up valuable storage space. Generally, they can be erased without difficulty.
After you have determined all the settings for the Surface checks, click OK to start
the checking process, or click Cancel to specify new settings.
Face Checks
When you click the Faces tab in the Geometry CHECK dialog box, a tabbed page
appears. It contains the following checks:
• Penetration or Distance of Boundaries (default check setting: > 0.02 mm)—
GeomIntegrityCHECK reports instances of penetration or contact of boundary
curves caused by using values lower than the minimum distance tolerance.
147
ModelCHECK - Help Topic Collection
1 TOL
Recommended solution:
Enlarge the space between boundary curves and remove loops. Where necessary,
partition faces or consolidate boundary curves.
• Proximity of Boundary Curve to its Surface (default check setting: < 0.02
mm)—In bounded surfaces, GeomIntegrityCHECK reports boundary curves with
too great a distance to the surface (normal or lateral). It also reports boundary
curves that extend beyond the parameter range of the surface.
1 TOL
2 Surface
This error would prevent the correct definition of a bounded surface. It would
require that the projection on the surface be performed once more in systems or
environments of greater exactness.
Recommended solution:
148
ModelCHECK
Create curves that are always within the range of tolerances of identical elements
as sectional curves or projections, or generate new ones where necessary.
Recommended solution:
Partially reverse the direction of rotation and recreate the bounded surface.
Such an error raises the risk of tiny elements as well as discontinuity, and it
impedes implementation of changes.
Recommended solution:
Correct or replace boundary curves and recreate the bounded surface with them.
After you have determined all the settings for the Face checks, click OK to start the
checking process, or click Cancel to specify new settings.
Topology Checks
149
ModelCHECK - Help Topic Collection
It is important for the topological explicitness of a surface that every inner face
edge must have one explicit neighboring face. That is, every inner face cannot
have more than one neighboring edge and must be free from bifurcation and
junctions. It is however permissible that a face edge borders on several
neighboring face edges, one after the other (T-type butt joint).
Recommended solution:
In the case of closed or unified groups, align all normals to the outside (away
from the material) or to the inside (toward the material). In the case of open
groups, reversal of the minority with a non-compliant orientation is optional.
150
ModelCHECK
The orientation of face normals within a topology must be uniform for the
determination of the machining direction by milling. The same condition is
necessary for hatched depictions and for ascertaining through the geometry the
capability for ejecting the part from the tool, or for the definition of the touch
direction by measuring.
Recommended solution:
Reverse individual face normals so that all face normals are topologically
uniformly oriented away from the material.
• Knife Edge (default check setting: > 2)—GeomIntegrityCHECK reports the faces
of composite surfaces whose angle between the tangential planes on a common
boundary curve (or parts thereof) shows properties of a minute angle of nearly 0
degrees. At the restart points and fulcrums, GeomIntegrityCHECK calculates the
angle between the tangential planes. GeomIntegrityCHECK reports all angles that
are around 0 degrees.
After you have determined all the settings for the Topology checks, click OK to start
the checking process, or click Cancel to specify new settings.
Solids Checks
When you click the Solids tab in the Geometry CHECK dialog box, a tabbed page
appears. It contains the following checks:
• Distance to Vertex Edge (default check setting: < 0.02 mm)—
GeomIntegrityCHECK reports the vertex and the edge in a solid if the distance
between the two elements exceeds the tolerance value specified in your
configuration file.
151
ModelCHECK - Help Topic Collection
1 Edge
3 Vertex
4 Face
The point that belongs to a vertex must lie within the configured tolerance on the
curve which is a part of the corresponding edge. If the distance between the
point and the curve exceeds the tolerance value, the solid is defective.
Recommended solution:
Project the point onto the curve. Otherwise, generate a new one.
Hence, for solids, the quality criteria for a closed (unified) group of faces are also
applicable. The criteria for surfaces, bounded surfaces (faces), and topologies are
correspondingly applicable to the bounded surfaces of a solid, including its
surfaces and boundary curves, that is, the distance from the bounded curves to
the surface.
152
ModelCHECK
1 Edge
2 Vertex
4 Face
The point on a vertex must lie within the configured tolerance on the associated
bounded surface. If the distance between the point and the face exceeds this
value, the solid is defective.
Recommended solution:
Project the point on the face, if possible. Otherwise, generate a new one.
In addition, it reports added material in component part areas that are already
filled with material, without altering the component part in any way (for example,
addition of a ball or sphere to a rectangular solid).
After you have determined all the settings for the Solids checks, click OK to start
the checking process, or click Cancel to specify new settings.
153
ModelCHECK - Help Topic Collection
Metrics Program
• The most frequent errors a certain user or groups of users are experiencing
When running the metrics program, reports and graphs are generated which you can
print and store as part of a quality program.
Note: Install version 3.0 of the metrics program and then upgrade to the 2000i
version.
STARTCHECK YNEW E E W W Y
PARAMCHECK YNEW E E W W Y
PARAM_SPELL YNEW E E W W N
154
ModelCHECK
Note: To make it easier to compile and manage data, it is recommended that the
directory specified by the DIR_METRICS configuration option be set to a central
location. All users need read and write access to this directory.
The directory specified by the DIR_REPORTS configuration option should be set to a
local directory on each user’s machine. This directory is written too often. If it is a
network directory, ModelCHECK slows down.
155
Index
G setconf.mcc ........................... 7, 28
ModelCHECK Files
condition.mcc ........................ 7, 29
config_init.mc ....................... 7, 11
External...................................... 7
Group....................................... 33
157