DCA25SSIU4F
Generator
WhisperWatt™
Prime Rating — 20 kW (25 kVA)
Standby Rating — 22 kW (27.5 kVA)
Three-Phase, 60 Hertz, 0.8 PF
STANDARD FEATURES
Heavy duty, 4-cycle, direct injection, heated crankcase vent, Fully covered power panel. Three-phase terminals and single
turbocharged diesel engine provides maximum reliability. phase receptacles allow fast and convenient hookup for most
EPA emissions certified - Tier 4 final emissions compliant. applications including temporary power boxes, tools and
Microprocessor engine control system maintains frequency lighting equipment. All are NEMA standard.
to ±0.25%. ECU754 microprocessor-based digital generator controller.
Full load acceptance of standby nameplate rating in a single • Remote 2-wire start/stop control.
step. • Operational temperature range of -40° to 85° C.
Fuel/water separator removes condensation from fuel for
extended engine life. Panel mounted alarm light included. Digital engine gauges including oil pressure, water temperature,
battery volts, engine speed and fuel level.
Sound attenuated, weather resistant, steel housing provides
operation at 65 dB(A) at 23 feet. Fully lockable enclosure Analog generator instrumentation including AC ammeter,
allows safe unattended operation. AC voltmeter, frequency meter, ammeter phase selector
switch, voltmeter phase selector switch, and voltage regulator
E-coat and powder coat paint provides durability and weather
adjustment potentiometer.
protection.
Automatic safety shutdown system monitors the water
Internal fuel tank with direct reading of fuel gauge.
temperature, engine oil pressure, overspeed and overcrank.
Spill containment — Bunded design protects environment by Warning lights indicate abnormal conditions.
capturing up to 124% of engine fluids.
Voltage selector switch allows easy to change voltages as
Brushless alternator reduces service and maintenance your applications require.
requirements and meets temperature rise standards for
Class F insulation systems.
• Open delta excitation design provides virtually unlimited
excitation for maximum motor starting capability.
• Automatic voltage regulator (AVR) provides precise
regulation.
SPECIFICATIONS
Generator Specifications Cooling System
Design Revolving field, self-ventilated Fan Load 0.67 hp (0.5 kW)
Drip-proof, single bearing
Coolant Capacity (with radiator) 2.3 gallons (8.8 liters)
Armature Connection Star with Neutral Zig Zag
Coolant Flow Rate (per minute) 20.1 gallons (76.0 liters)
Phase 3 Single
Standby Output 22 KW (27.5 KVA) 15.8 KW Heat Rejection to Coolant (per minute) 1479 Btu (1.56 MJ)
Prime Output 20 KW (25 KVA) 14.4 KW Maximum Coolant Friction Head 14.5 psi (100 kPa)
3Ø Voltage (L-L/L-N) 208Y/120, 220Y/127, N/A
Maximum Coolant Static Head 3.35 feet (1.04 meters)
Voltage Selector Switch at 3Ø 240/139 240Y/139
Ambient Temperature Rating 104°F (40°C)
3Ø Voltage (L-L/L-N) 416Y/240, 440Y/254, N/A
Voltage Selector Switch at 3Ø 480/277 480Y/277
1Ø Voltage (L-L/L-N) N/A 240/120
Air
(Voltage Selector Switch at 1Ø 240/120)
Combustion Air 109 cfm (3.10 m3/min)
Power Factor 0.8 1.0
Maximum Air Cleaner Restriction 25 in. H2O (6.23 kPa)
Voltage Regulation (No load to full load) ±0.5%
Generator RPM 1800 Alternator Cooling Air 388 cfm (11.0 m3/min)
Frequency 60 Hz Radiator Cooling Air 1420 cfm (40.2 m3/min)
Winding Pitch 5/6 Minimum Air Opening to Room 2.6 ft2 (0.24 m2)
No. of Poles 4 Minimum Discharge Opening 0.84 ft2 (0.08 m2)
Excitation Brushless with AVR
Frequency Regulation: Isochronous under varying loads from Exhaust System
No Load to Full Load no load to 100% rated load
±0.25% of mean value for constant loads Gas Flow (full load) 148 cfm (4.2 m3/min)
Frequency Regulation: Steady State from no load to full load. Gas Temperature 847°F (453°C)
Insulation Class F
Maximum Back Pressure 30.1 in. H2O (7.5 kPa)
Sound Level dB(A) Full load at 23 feet 65
49.61 in
(1260 mm) Denyo
18.31 in
(465 mm)
65.30 in
(1658.62 mm)
Denyo
105.81 in
56.13 in (2687.57 mm)
(1425.70 mm)